36C25018B0815-0002009.pdf
PDF 429 KB Posted
- Solicitation number
- 36C25018B0815
About this file
36C25018B0815 0002 T8-01.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25019C0025-000.docx | DOCX document | |
| 36C25018B0815-0003000.docx | DOCX document | |
| 36C25018B0815-0002007.pdf | ||
| 36C25018B0815-0002004.pdf | ||
| 36C25018B0815-0002002.pdf | ||
| 36C25018B0815-0002006.pdf | ||
| 36C25018B0815-0002005.pdf | ||
| 36C25018B0815-0002003.pdf | ||
| 36C25018B0815-0002000.docx | DOCX document | |
| 36C25018B0815-0002008.pdf | ||
| 36C25018B0815-0002001.pdf | ||
| 36C25018B0815-0002010.pdf | ||
| 36C25018B0815-0001000.docx | DOCX document | |
| 36C25018B0815-003.pdf | ||
| 36C25018B0815-001.docx | DOCX document | |
| 36C25018B0815-004.txt | TXT text file | |
| 36C25018B0815-002.pdf | ||
| 36C25018B0815-000.docx | DOCX document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PB
S
793.98 CL Conc
30063
4.3
0.6
7.3
0.5
0.8
A.5
CONC
F F
F
V
UPPER
LANDING
1T001C
MID LANDING
1T001B
VESTIBULE
1T001A
11' - 5 3/8"
MOBILE SPS TRAILER
NEW TEMPORARY CORRIDOR
PLAN NOTES
1.- PROVIDE FIRE ALARM ADDRESSABLE MONITORING FOR MOBILE SPS TRAILER
FIRE ALARM SYSTEM. CONNECT TO TRAILER'S RJ-45 CONNECTION. MONITOR
FOR ALARM AND TROUBLE. COORDINATE ALL CONNECTIONS WITH MOBILE SPS
TRAILER PROVIDER.
2.- EXISTING TELECOMMUNICATIONS ROOM "HC-15," ROOM #1B006.
3.- PROVIDE A NEW 6-STRAND, 62.5-MICRON MULTIMODE FIBER (TO MATCH
EXISTING) BETWEEN TR "HC-15" AND THE TEMPORARY STERILE PROCESSING
TRAILER. PROVIDE A 2" MANUFACTURED FIRE-RATED SLEEVES AT ANY FIRE-
RATED WALL PENETRATIONS. TERMINATE FIBER ON BOTH ENDS IN A WALL
MOUNTED FIBER PATCH PANEL WITH LC CONNECTORS. INSTALL THE WALL
MOUNTED FIBER PATCH PANEL ON THE WEST WALL WITHIN "HC-15". FIELD
COORDINATE THE EXACT LOCATION OF THE WALL MOUNTED FIBER PATCH
PANEL WITHIN THE TRAILER WITH THE TRAILER SUPPLIER. THIS LOCATION SHALL
BE WITHIN 5' OF THE NETWORK RACK SUPPLIED WITH THE TRAILER. PROVIDE
THREE 10' LC TO SC CONNECTOR PATCH CORDS WITHIN TR "HC-15" AND WITHIN
THE TRAILER.
4.- PROVIDE NEW FIRE ALARM DEVICES AS SHOWN. FIRE ALARM DEVICES ARE TO
BE AN EXTENSION OF THE EXISTING SYSTEM.
5-. LOCATION OF EXISTING FIRE ALARM CONTROL PANEL. COORDINATE
ROUTING OF CONDUIT FOR FIRE ALARM FEEDS WITH ALL EXISTING CONDITIONS.
6.- APPROXIMATE ROUTING LOCATION FOR FIRE ALARM CONNECTION TO
MOBILE SPS.
7.- PROVIDE TAMPER SWITCH FOR FIRE SUPPRESSION SYSTEM EXTENSION.
INTEGRATE FLOW AND TAMPER SWITCH TO THE EXISTING FIRE ALARM SYSTEM.
PROVIDE ALL REQUIRED RELAYS AND EQUIPMENT FOR MONITORING OF
SWITCHES BY FIRE ALARM SYSTEM.
Drawing Title
Approved:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
CONSULTANTS:
SCHEMATIC DESIGN REVISIONS - 25% REVIEW SET 2015 10-21
1A
FARID MEHR, PE
CHIEF, ENGINEERING SERVICE
SCHEMATIC DESIGN - 25% REVIEW SET 2015 10-07
DESIGN DEVELOPMENT ONE - 50% REVIEW SET 2015 11-25
DESIGN DEVELOPMENT TWO - 75% REVIEW SET 2016 02-03
CONSTRUCTION DOCUMENTS - 95% REVIEW SET 2016 03-30
BID DOCUMENTS - 100% SET 2016 05-11
BID DOCUMENTS - 100% SET REVISED 2016 11-18
C :\U se rs
\m ba ke r\D oc um en ts
\1
TE
C
H _C en tra l_ m ba ke r.r vt
BID DOCUMENTS - BID
T8.01
DELDEL
Technology Site Plan
2016-05-11
757-16-101EXPAND LAB AND SPS
DEPARTMENTS
1/16" = 1'-0"T8.01
1 TECHNOLOGY SITE PLAN
GI
RS
S
R P
F E
O
E E T
L
I G
S
N A O N
RE
E
D
I
R
S
E N
E
HTAT
S
E OF
MACE E-50556
O
OI
MONTGOMERY E-66852
GRIFFIN E-57049
File details come from the government source that posted it.