36C25018B0815-0002003.pdf
PDF 2 MB Posted
- Solicitation number
- 36C25018B0815
About this file
36C25018B0815 0002 A8-03.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25019C0025-000.docx | DOCX document | |
| 36C25018B0815-0003000.docx | DOCX document | |
| 36C25018B0815-0002007.pdf | ||
| 36C25018B0815-0002004.pdf | ||
| 36C25018B0815-0002002.pdf | ||
| 36C25018B0815-0002006.pdf | ||
| 36C25018B0815-0002005.pdf | ||
| 36C25018B0815-0002000.docx | DOCX document | |
| 36C25018B0815-0002008.pdf | ||
| 36C25018B0815-0002001.pdf | ||
| 36C25018B0815-0002010.pdf | ||
| 36C25018B0815-0002009.pdf | ||
| 36C25018B0815-0001000.docx | DOCX document | |
| 36C25018B0815-003.pdf | ||
| 36C25018B0815-001.docx | DOCX document | |
| 36C25018B0815-004.txt | TXT text file | |
| 36C25018B0815-002.pdf | ||
| 36C25018B0815-000.docx | DOCX document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A8.03
A8.03
TOP OF ROOF
116'-2"
EL. FINISH FLR
100'-0"
TOP OF ROOF
114'-6"
TOP OF ROOF
116'-2"
EL. FINISH FLR
100'-0"
TOP OF ROOF
114'-6"
EL. FINISH FLR
100'-0"
TOP OF ROOF
114'-6"
TOP OF ROOF
114'-8"
A B
C D
E F G
A8.03
A8.03
A8.03
T1-11 WOOD SIDING
PAINTED
PREFINISH ALUM. DOWNSPOUT
& GUTTER.CONNECT TO STORM
SEWAGE SYS.
SINGLE HUNG ALUM.
WINDOW UNIT W/ 4" WD.
WINDOW TRIM
MEMBRANE ROOFING
PREFINISH ALUM. DOWNSPOUT &
GUTTER
4" WD. WINDOW TRIM
PAINTED
LINE OF RAMP
PREFINISH ALUM. DOWNSPOUT
& GUTTER.CONNECT TO STORM
SEWAGE SYS.
SINGLE HUNG ALUM.
WINDOW UNIT W/ 4" WD.
WINDOW TRIM
T1-11 WOOD SIDING
PAINTED
LINE OF EXISTING
BUILDING
ELECTRICAL SERVICE
ENTRANCE. SEE MEP DWGS.
T1-11 WOOD SIDING
PAINTED
T1-11 WOOD SIDING
PAINTED
T1-11 WOOD SIDING
PAINTED
MEMBRANE ROOFING
LINE OF CEILING LINE OF CEILING
LINE OF CEILING
LINE OF CEILING
LINE OF CEILING
LINE OF CEILING
WALL MOUNTED MECH.
UNIT. REFER TO MEP.
DWGS
T1-11 WOOD SIDING
PAINTED
MOBILE SPS
BY OTHER
FINISH FLOOR TO
FLUSH W/ MOBILE
SPS. FLOOR EXP.
JOINT SEE DETAIL
3/A8.03 & PROJECT
MANUAL.
FLOOR, CEILING
& WALLS
COMPRESSION SEALS
SEE DETAIL 4,5/A8.03 &
PROJECT MANUAL
LINE OF MECH. UNIT
REFER MEP DWGS.
LINE OF MECH. UNIT
REFER MEP DWGS.
LINE OF MECH. UNIT
REFER MEP DWGS.
CARD READER
WALL MOUNTED
MECH. UNIT. REFER
TO MEP. DWGS.
T1-11 PLYWOOD SIDING ON
BUILDING PAPER ON 5/8" EXT. SHEATHING
WITH R 13 FIBERGLASS INSULATION
AND 5/8" WALLBOARD
VCT FLOORING ON
2 LAYERS OF 3/4" SUB FLOOR
MEMBRANE ROOFING ON 2" RIGID INSULATION
OVER 5/8" ROOF SHEATHING WITH MIN. 1/4" SLOPE
3'-0 X 3'-6" ALUM. WINDOW UNIT
W/ 4" WD. WINDOW TRIM. PAINTED.
SEE PLAN FOR LOCATION. TYP OF 4
1/2" DIA, 6" LONG SIMPSON TITEN HD
@ EA STUD, TYP.
8", 18GA MTL JOIST (800S162-43) AT EACH
STUD. SLOPED STRUCT. FOR ROOF SLOPE
1/4" MIN.
8", 18GA MTL JOIST (800S162-43)
@ EA MTL STUD
BENT PL 12GA 4"X2"X4" LONG @ EA STUD.
CONNECT TO STUD W/ (4) #12 TEK SCREWS, TYP.
8", 18GA TRACK, #12 TEK SCREW @ EACH JOIST
3 5/8", 18GA (362S162-43) MTL. STUD @ 16"O.C.
TRIM FLANGES @ VERT STUDS AND JOIST.
(IF NECESSARY)
(4) #12 TEK SCREWS EA END, TYP.
6", 16GA (600S250-54) MTL STUD @ 16" O.C.
INSTALL BRIDGING @ 6'-0" O.C. MAX. TYP.
CONT. #4 BAR, TYP.
1 1/2" DIA. STAINLESS STL
HANDRAIL
WD. WINDOW SILL PAINTED
NOTE: WHERE TOP OF
RAMP JOIST IS LESS THAN
1'-0" ABOVE CONC. SLAB,
DO NOT INSTALL BRACES
BELOW RAMP
(4) #12 TEK SCREWS EA END OF JOIST.
ACOUSTICAL CEILING TILE
SEE PROJECT MANUAL
6", 18GA TRACK, TYP.
6", 18GA TRACK AT HEAD & SILL,
CLIP FLANGE & BEND WEB TO
CONNECT TO JAMB STUD
1/4"/ 1'-0" MIN.
1' - 0"
V A
R
IE
S .2
KEEP FINISH GRADE 6" BELOW
FINISH FLOOR ELEVATION
MTL. EDGE FLASHING
.2'-6" TYP.
.4
4" VINYL BASE
MOBILE
SPS UNIT
COMPRESSION SEAL
COORDINATE WITH
MOBILE SPS PROVIDER
FLOOR FINISH
MATERIAL
PROVIDE
BLOCKING TO
SECURE JOINT
AT PLATFORM
ONLY
METAL EXP.
JOINT COVER
FLUSH
BETWEEN
FLOORS ELEV.
COMPRESSION SEAL.
REFER TO PROJECT
MANUAL &
COORDINATE WITH
MOBILE SPS PROVIDER
MOBILE
SPS UNIT
EXTERIOR SIDING
WATER TIGHT
COMPRESSION SEAL.
REFER TO PROJECT
MANUAL.
EXISTING
BUILDING
FRT WOOD BLOCKING
MEMBRANE ROOFING ON
RIGID INSULATION
OVER 5/8" ROOF
SHEATHING
1"
/2
EXISTING MTL. PANEL
TO BE PROTECTED
Expires 12/31/2017 Mark R Hollern 08833
11 / 18 / 2016
Drawing Title
Approved:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
CONSULTANTS:
SCHEMATIC DESIGN REVISIONS - 25% REVIEW SET 2015 10-21
1A
FARID MEHR, PE
CHIEF, ENGINEERING SERVICE
SCHEMATIC DESIGN - 25% REVIEW SET 2015 10-07
DESIGN DEVELOPMENT ONE - 50% REVIEW SET 2015 11-25
DESIGN DEVELOPMENT TWO - 75% REVIEW SET 2016 02-03
CONSTRUCTION DOCUMENTS - 95% REVIEW SET 2016 03-30
BID DOCUMENTS - 100% SET 2016 05-11
BID DOCUMENTS - 100% SET REVISED 2016 11-18
C T e m p \R e v it L o c a lF ile s \1
V
A L a b a n d S
P S
-1
-1 m a rk h .r v t
BID DOCUMENTS - BID
A8.03
ATRK
SPS Temporary Trailer Ramp - Ext Elevations
2016-11-18
757-16-101
EXPAND LAB AND SPS
DEPARTMENTS
1/4" = 1'-0"A8.03
1 elevations - ramp
3/4" = 1'-0"A8.03
2 section - ramp
3" = 1'-0"A8.03
3 exp. joint - floor 3" = 1'-0"A8.03
4 compression joint - wall & ceiling 1 1/2" = 1'-0"A8.03
5 compression joint - wall & roof
File details come from the government source that posted it.