36C25018B0815-0002001.pdf
PDF 3 MB Posted
- Solicitation number
- 36C25018B0815
About this file
36C25018B0815 0002 A8-01.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25019C0025-000.docx | DOCX document | |
| 36C25018B0815-0003000.docx | DOCX document | |
| 36C25018B0815-0002007.pdf | ||
| 36C25018B0815-0002004.pdf | ||
| 36C25018B0815-0002002.pdf | ||
| 36C25018B0815-0002006.pdf | ||
| 36C25018B0815-0002005.pdf | ||
| 36C25018B0815-0002003.pdf | ||
| 36C25018B0815-0002000.docx | DOCX document | |
| 36C25018B0815-0002008.pdf | ||
| 36C25018B0815-0002010.pdf | ||
| 36C25018B0815-0002009.pdf | ||
| 36C25018B0815-0001000.docx | DOCX document | |
| 36C25018B0815-003.pdf | ||
| 36C25018B0815-001.docx | DOCX document | |
| 36C25018B0815-004.txt | TXT text file | |
| 36C25018B0815-002.pdf | ||
| 36C25018B0815-000.docx | DOCX document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PB
S
793.98 CL Conc
30063
4.3
7.3
0.5
0.8
A.5
METAL TRAILERS
LANDSCAPED AREA
LOCATION OF SPEC CARE ADDITION
UNDER CONSTRUCTION BY OTHER
UPPER
LANDING
1T001C
MID LANDING
1T001B
VESTIBULE
1T001A
11' - 5 3/8"
NEW CONC PAVEMENT
SEE CIVIL DWGS.
UTILITIES HOOK UP
LOCATION SEE MEP DWGS.
SEE SHEET A8.02
FOR ENLARGED
PLANS
CONC SAFETY
BARRIER. SEE CIVIL DWGS.
ALIGN EXT. WALL W/
EXIST. CANOPY. VIF. CONC SAFETY
BARRIER
TEMPORARY
MOBILE STERILE
PROCESSING
TRAILER UNIT
EXISTING
DUMPSTER
EXIST.
GENERATOR
LINE OF EXIST. CANOPY
VIF.
NOTE: CONC PAD
TO REMAIN AFTER
MOBILE UNIT IS
REMOVED
NOTE: REMOVE
VESTIBULE AND
TEMPORARY
CORRIDOR AND
FOUNDATIONS
AFTER MOBILE
UNIT IS REMOVED
EXISTING VA FACILITY
A8.02
A. SEE CIVIL ENGINEERING DRAWINGS FOR CONCRETE PAD, SITE UTILITIES & EXISTING SITE INFORMATION.
B. SEE MEP DRAWINGS FOR FIRE PROTECTION, ELECTRICAL, MECHANICAL & PLUMBING OF TEMPORARY
RAMP FOR MOBILE PROCESSING UNIT & UTILITY SERVICE ENTRANCE.
C. ALL DAMAGE TO EXISTING PAVEMENT TO REMAIN WHICH RESULTS FROM THE CONTRACTORS OPERATIONS
SHALL BE REPLACED WITH LIKE MATERIALS AT THE CONTRACTOR'S EXPENSE.
D. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS IN THE FIELD PRIOR TO THE START OF CONSTRUCTION. THE CONSTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND ELEVATIONS DURING THE ENTIRE CONSTRUCTION SCHEDULE. IF ANY DISCREPANCIES ARE FOUND IN THESE PLANS FROM ACTUAL FIELD DIMENSIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEER/ ARCHITECT IMMEDIATELY.
E. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT BUILDING DIMENSIONS AND LOCATIONS OF UTILITY
SERVICES ENTRANCE, BUILDING DRAINS, ROOF DRAINS, DOORS AND EXIT FEATURES.
SITE PLAN GENERAL NOTES
Expires 12/31/2017 Mark R Hollern 08833
11 / 18 / 2016
Drawing Title
Approved:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
CONSULTANTS:
SCHEMATIC DESIGN REVISIONS - 25% REVIEW SET 2015 10-21
1A
FARID MEHR, PE
CHIEF, ENGINEERING SERVICE
SCHEMATIC DESIGN - 25% REVIEW SET 2015 10-07
DESIGN DEVELOPMENT ONE - 50% REVIEW SET 2015 11-25
DESIGN DEVELOPMENT TWO - 75% REVIEW SET 2016 02-03
CONSTRUCTION DOCUMENTS - 95% REVIEW SET 2016 03-30
BID DOCUMENTS - 100% SET 2016 05-11
BID DOCUMENTS - 100% SET REVISED 2016 11-18
C T e m p \R e v it L o c a lF ile s \1
V
A L a b a n d S
P S
-1
-1 m a rk h .r v t
BID DOCUMENTS - BID
A8.01
ATRK
Architectural Site Plan
2016-11-18
757-16-101
EXPAND LAB AND SPS
DEPARTMENTS
1/16" = 1'-0"A8.01 site plan - temporary mobile sterile processing
File details come from the government source that posted it.