36C25018B0795-017.pdf

PDF 10 MB Posted

Attached to
Construct Clinical and Admin Building 506-329 Federal contract opportunity
Solicitation number
36C25018B0795
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

36C25018B0795 506-329 VA Ann Arbor Admin Bldg BID DWGS REVISED_Part7.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Construct Clinical and Admin Building 506-329, newest first.
File Type Posted
36C25018B0795-0005000.docx DOCX document
36C25018B0795-0004000.docx DOCX document
36C25018B0795-0003000.docx DOCX document
36C25018B0795-0003001.xlsx XLSX spreadsheet
36C25018B0795-0002000.docx DOCX document
36C25018B0795-0001002.pdf PDF
36C25018B0795-0001000.docx DOCX document
36C25018B0795-0001001.pdf PDF
36C25018B0795-011.pdf PDF
36C25018B0795-019.pdf PDF
36C25018B0795-021.pdf PDF
36C25018B0795-013.pdf PDF
36C25018B0795-009.docx DOCX document
36C25018B0795-010.pdf PDF
36C25018B0795-008.docx DOCX document
36C25018B0795-020.pdf PDF
36C25018B0795-012.pdf PDF
36C25018B0795-007.docx DOCX document
36C25018B0795-016.pdf PDF
36C25018B0795-015.pdf PDF
36C25018B0795-018.pdf PDF
36C25018B0795-022.docx DOCX document
36C25018B0795-014.pdf PDF
36C25018B0795-000.docx DOCX document
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 1/2" HHWS

1 1/2" HHWR

FPB-02-7

FPB-02-5

TU-02-2

TU-02-3

FPB-02-4

FPB-02-3

TU-02-1

FPB-02-2

FPB-02-1

FPB-02-10

FPB-02-9

TU-02-5

FPB-02-8

TU-02-4

MEN'S TOILET

HAC

IT

ELECTRICAL

ASSISTANT CHIEF

CHIEF

UNISEX RR

OPEN OFFICE

AFO

CFO

INTERNAL AUDITOR

STAIRS

S-1

ELEVATOR

E-1

STAIRS

S-2

VESTIBULE

CORRIDOR

OPEN OFFICE

OPEN OFFICE

CORRIDOR

ACCOUNTING

SUPERVISOR

OPEN OFFICE

ELEVATOR LOBBY

BREAK ROOM

CONFERENCE ROOM

WOMEN'S TOILET

PAYROLL SUPERVISOR

MCA PROGRAM OFFICE

COFFEE

A B C D

H

E

4.2

J

2.8

4.8

G

5.4

F K

1" HHWS

1" HHWR

1" HHWR

1" HHWS

1" HHWS

1" HHWR

1/2" HHWR

1/2" HHWS

1" HHWR

1" HHWS

1" HHWR

1" HHWS

1/2" HHWR

1/2" HHWS

1/2" HHWR

1/2" HHWS

1" HHWR

1" HHWS

1" HHWS

1" HHWR

1" HHWR

1" HHWS

1" HHWR

1" HHWS

1" HHWR

1" HHWS

1" HHWR

1" HHWS

1 1/4" HHWS

1 1/4" HHWR

1 1/4" HHWS

1 1/4" HHWR

2" HHWR/S DN

1 1/2" HHWR/S UP

IN CHASE

1/2" HHWR

1/2" HHWS

1" HHWS

1" HHWR

T

T

DDC

CONTROL

PANEL

ACCU-1

REFRIGERANT

PIPING UP/DN

T

1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222

SSOE, Inc.

D A T E

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

VA ANN ARBOR MEDICAL CENTER CAMPUS

PROJECT #: 015-01361-00

BIDS SUBMISSION_REVISED

C A u to d e s k \R e v it \0 M S S O E .r v t

/9 /2 :5 :3 A M

Scale: 3/16" = 1'-0"

MP120

PIPING SECOND FLOOR PLAN

GOTWALD

506-329CLINICAL & ADMINISTRATIVE

BUILDING

WILSON04-12-18

111 148

N

SCALE: 3/16" = 1'-0"

SECOND FLOOR PIPING PLAN

T

T

T

T

T

T

T

TT

T

GENERAL NOTES:

1. REFRIGERANT PIPING SHOWN AS GENERAL ROUTING. SIZING AND ACCESSORIES PER

MANUFACTURERS INSTALLATION INSTRUCTIONS.

KEY NOTES:

1 NOT USED

2 PROVIDE 3 WAY CONTROL VALVE AT THIS UNIT TO MAINTAIN BRANCH TEMPERATURE.

3 BID DEDUCT ALTERNATE NO. 7: ADD HOT WATER COILS TO INTERIOR TERMINAL UNITS IF

THIRD FLOOR IS A SEMI-HEATED SHELL SPACE.

DESIGN DEVELOPMENT SUBMISSION 1 04-19-16

DESIGN DEVELOPMENT SUBMISSION 2 06-10-16

95% CONSTRUCTION DOCUMENTS

SUBMISSION

11-15-16

BIDS SUBMISSION 01-20-17

BIDS SUBMISSION_REVISED 04-12-18

CONF. ROOM

ASST CHIEF MAS OFF

NON-VA CARE SUPV

WOMEN'S TOILET

VESTIBULE

MEN'S TOILET

HAC

IT

ELECTRICAL

HBU SUPRVISOR

CHIEF MAS OFFICER

327 SCANNING SUPV

RECORD MANAGER

OFFICER

MED RECORDS

SUPERVISOR

CODING SUPERVISOR

OFFICE

ADMINISTRATIVE

OFFICER

ELEVATOR LOBBY

STAIRS

S-1

ELEVATOR

E-1

STAIRS

S-2

COFFEE

OPEN OFFICE

OPEN OFFICE

OPEN OFFICE

CORRIDOR

OPEN OFFICE

CORRIDOR

1 1/2" HHWS

1 1/2" HHWR

A

A

B

B

C

C

D

D

6 6

5 5

3 3

2 2

H

HE

E

4.2

4.2

4 4

J

J

2.8

2.8

4.8

4.8

G

G

5.45.4

F

F

K

K

FPB-03-7

TU-03-4

FPB-03-8

TU-03-5 FPB-03-9

FPB-03-10

FPB-03-3

FPB-03-4

FPB-03-5

TU-03-2

TU-03-3

OPEN OFFICE

OPEN OFFICE

1" HHWS

1" HHWR

1" HHWR

1" HHWS

1" HHWR

1" HHWS

1" HHWS

1" HHWR

1" HHWS

1" HHWR

1" HHWS

1" HHWR

1 1/4" HHWS

1 1/4" HHWR

1 1/4" HHWS

1 1/4" HHWR

1" HHWS

1" HHWR

1" HHWR

1" HHWS

1" HHWS

1" HHWR

1" HHWS

1" HHWR

1/2" HHWR

1/2" HHWS

1" HHWS

1" HHWR

1" HHWS

1" HHWR

1" HHWS

1" HHWR

1" HHWR

1" HHWS

FP-03-1

1 1/2" HHWR/S DN

IN CHASE

T

T

T

T

T

T

T

T

T

T

T

T

DDC

CONTROL

PANEL

TU-03-1

T

FPB-03-2

ACCU-1

REFRIGERANT

PIPING UP

ACCU-1

REFRIGERANT

PIPING DN

T

1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222

SSOE, Inc.

D A

T E

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

VA ANN ARBOR MEDICAL CENTER CAMPUS

PROJECT #: 015-01361-00

BIDS SUBMISSION_REVISED

C A u to d e s k \R e v it \0

M

S

S O

E .r v t

/9

/2

:5

:4

A

M

Scale: 3/16" = 1'-0"

MP130

PIPING THIRD FLOOR PLAN

GOTWALD

506-329CLINICAL & ADMINISTRATIVE

BUILDING

WILSON04-12-18

112 148

N

SCALE: 3/16" = 1'-0"

THIRD FLOOR PIPING PLAN

GENERAL NOTES:

1. REFRIGERANT PIPING SHOWN AS GENERAL ROUTING. SIZING AND ACCESSORIES PER

MANUFACTURERS INSTALLATION INSTRUCTIONS.

KEY NOTES:

1 BID DEDUCT ALTERNATE NO 6: DELETE REFRIGERANT PIPING AND ACCU-1.

2 PROVIDE 3 WAY CONTROL VALVE AT THIS UNIT TO MAINTAIN BRANCH TEMPERATURE.

DESIGN DEVELOPMENT SUBMISSION 1 04-19-16

DESIGN DEVELOPMENT SUBMISSION 2 06-10-16

95% CONSTRUCTION DOCUMENTS

SUBMISSION

11-15-16

DRAW THRU

BLOW THRU

2" [50mm]

PLUS X

1" [25mm]

MINIMUM

X

2X

UNIT TYPE A B

WHERE X = STATIC PRESSURE IN PAN

NOTE: 1. CPVC PIPE MAY BE USED ONLY IF APPROVED BY LOCAL VA AND

IS INDOORS AND DOES NOT PASS THROUGH RATED BARRIERS.

2. DIELECTRIC FITTING TO BE USED WHEN TWO DISSIMILAR METALS ARE

TO BE CONNECTED.

A B

[2 m m

DRAIN LINE SHALL BE AT LEAST THE SAME

SIZE AS THE NIPPLE ON THE DRAIN PAN.

PIPING SHALL BE RIGID COPPER TYPE L

OR TYPE M UNLESS NOTE BELOW IS MET

PITCH DOWN

TOWARD

DRAIN

CLEAN OUT

FLOOR SINK

DIELECTRIC

FITTING

DRAIN PAN

NOTES:

1. SUPPORT PUMP FROM PIPING ONLY. DO NOT SUPPORT PUMP FROM MOTOR.

BALANCING

DEVICE

PIPE HANGERS - PROVIDE DOUBLE

DEFLECTION NEOPRENE (TYPE HN)

FOR FIRST TWO ON EACH SIDE OF

PUMP (SEE NOTE NO. 1)

PRESSURE GAGE

1/2" [15mm]

STRAINER

BALL OR

BUTTERFLY

(TYP.)

FLEXIBLE

CONNECTION

COIL

WATER RETURN

WATER SUPPLY

MV

UNION

CONNECTIONS (TYP.)

TEST PLUG (TYP.)

MANUAL AIR VENT

DRAIN WITH HOSE

CONNECTION

SHUT OFF VALVE

REDUCER, IF REQUIRED

MODULATION CONTROL VALVE

SINGLE COIL

WATER COIL

WATER COIL

WATER COIL

DOUBLE COIL

NOTES:

1. WHEN COIL IS INCLUDED IN CASING MOUNTED ON VIBRATION ISOLATORS THE FIRST 2 HANGERS FOR EACH PIPE SHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR 4" [100mm] PIPE & SMALLER. TYPE "H-P" FOR 5" [125mm] PIPE & LARGER.

2. PIPING SHALL BE INSTALLED IN SUCH MANNER THAT IT WILL NOT BLOCK THE SWING OR USE OF ACCESS DOORS OR

PANELS; NEITHER SHALL IT BLOCK THE SERVICING OF FILTERS, VALES, OR EQUIPMENT.

3. THE FLOW ELEMENT MAY BE INSTALLED IN THE SUPPLY PIPING IF THE REQUIRED MINIMUM UPSTREAM AND DOWNSTREAM

DIMENSIONS CANNOT BE OBTAINED IN THE RETURN PIPING.

FE

MV

MV

MV

MV

MVMV

FE

TI

TI

MV

AIR VENT WHEN

COIL IS NOT

SELF-VENTING

DRAIN WHEN COIL IS

NOT SELF-DRAINING

PIPE HANGER SHALL SUPPORT

PIPING INDEPENDENT OF COIL

AIR VENT WHEN

COIL IS NOT

SELF-VENTING

DRAIN WHEN COIL IS

NOT SELF-DRAINING

DRAIN

REDUCER, IF REQUIRED

TEMPERATURE

INDICATION TO ECC

SEE CONTROL

DIAGRAM

REDUCER, IF REQUIREDPIPE HANGER SHALL SUPPORT

PIPING INDEPENDENT OF COIL

TEST

PLUG

(TYP.

TEST

PLUG

(TYP.)

FLOW ELEMENT

DRAIN

NOTE:

TOP OF CHEMICAL POT FEEDER

TANK SHALL NOT BE MORE THAN

4'-0" [1200mm] ABOVE FINISHED

FLOOR.

F R

O M

P U

M P

D

IS

C H

A R

G E

T O

P U

M P

S U

C T

IO

N

AUTOMATIC FLOW

CONTROL AND BALANCE

DEVICE

FUNNEL

3/4" [20mm]

TO DRAIN

1" [25mm]

CHEMICAL POT FEEDER-

MINIMUM CAPACITY

5 GALLONS [19L]

1" [25mm]

NOTE:

1.

2.

SEE EXPANSION TANK SYSTEM

SCHEDULE FOR COMPONENT

SIZES.

SET PRESSURE REDUCING

VALVE SO PRESSURE AT

HIGHEST POINT IN SYSTEM HAS

A MINIMUM OF 4 PSIG [28kPa].

D

DRAIN

DRAIN

TO PUMP

SUCTION

BLADDER

EXPANSION

TANK

NC

MV

AUTO. AIR VENT TO DRAIN

CONNECTOR PIPE.

HANGER

RODS (TYP)

AIR SEPARATOR

BUTTERFLY

OR BALL

ISOLATION

VALVE

RUN DRAIN LINE TO NEAREST

FD UNLESS INDICATED

OTHERWISE

FROM SYSTEM

6" [150mm]

HOUSEKEEPING PAD

AIR CHARGING

SHRAEDER VALVE

CONNECT TO BFP

SHOWN ON

PLUMBING

DRAWINGS

FLOOR MOUNTING BASE RING WITH

DRAIN ACCESS OPENING SHOWN.

ANGLE IRON LEGS MAY BE USED

AS AN OPTION.

PI

ELEVATION

THREADED PIPING

ELEVATION

WELDED PIPING

NOTES:

1. DRAIN ALL LOW POINTS AS INDICATED ABOVE.

2. WHERE SCALE POCKETS ARE SHOWN ON PIPE RISER DIAGRAMS AND/OR

PLANS LOCATE DRAIN AT BOTTOM OF SCALE POCKET.

REDUCER, IF REQUIRED

3/4" [20mm] BALL VALVE

ADAPTER TO 3/4" [20mm] HOSE

THREAD-PROVIDE HOSE CAP

NUT

TYPICAL WATER PIPING

TYPICAL MANUAL AIR VENT

ELEVATION

NOTES:

1. VENT ALL HIGH POINTS INDICATED ABOVE.

2. IF AUTOMATIC AIR VENTS ARE USED, PIPE DISCHARGE TO DRAIN.

MV

OR

AV

CIRCULATING

WATER

PIPING

1/2" [15mm] x 4" [100mm]

NIPPLE

1/4" [8mm]

COPPER TUBING

1/2" [15mm]

BALL

VALVE

AIR VENT

BOILER

UNION (TYP)

STRAINER (TYP)

PRESSURE GAUGE (TYP)

TEMPERATURE GAUGE (TYP)

LOW POINT DRAIN (TYP)

PUMP

CHECK VALVE (TYP)

TO NEAREST

FLOOR DRAIN

(TYP)

1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222

SSOE, Inc.

D A

T E

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

VA ANN ARBOR MEDICAL CENTER CAMPUS

PROJECT #: 015-01361-00

BIDS SUBMISSION_REVISED

C A u to d e s k \R e v it \0

M

S

S O

E .r v t

/9

/2

:5

:4

A

M

Scale: 12" = 1'-0"

MP500

MECHANICAL PIPING DETAILS

GOTWALD

506-329CLINICAL & ADMINISTRATIVE

BUILDING

WILSON04-12-18

113 148

SCALE: NOT TO SCALE

1 AIR HANDLING UNIT DRAIN TRAP DETAIL

SCALE: NOT TO SCALE

2 IN-LINE PUMPS - CONNECTIONS

SCALE: NOT TO SCALE

9 TERMINAL UNIT WATER COILS - PIPING CONNECTIONS

SCALE: NOT TO SCALE

4 WATER COILS - PIPING CONNECTIONS

SCALE: NOT TO SCALE

5 WATER TREATMENT - CLOSED SYSTEM

SCALE: NOT TO SCALE

6 FLOOR MOUNTED EXPANSION TANK - PIPING CONNECTIONS

SCALE: NOT TO SCALE

7 TYPICAL DRAIN VALVE CONNECTIONS

SCALE: NOT TO SCALE

8 TYPICAL AIR VENT CONNECTIONS

SCALE: NOT TO SCALE

3 BOILER DETAIL

95% CONSTRUCTION DOCUMENTS

SUBMISSION

11-15-16

D

H

E

4.2

4.2

J

2.8

2.8

4.8

4.8

G

F K

MECHANICAL

SPRINKLERS

IT

ELEV. MAC. RM.

STAIRS

S-1

ELEVATOR

E-1

ELECTRICAL

HAC

CORRIDOR

CORRIDOR

CORRIDOR

ER-4

360 CFM

"x

14"x12"

SR-2

400 CFM

12"x6"

SR-2

270 CFM

2-F/S DPR

SR-1

175 CFM

SR-1

125 CFM

"x

"x

"x

10"x4"

TU-00-3

TU-00-1

10"x10"

TU-00-2

SR-2

200 CFM

CUH-2

8" X 10"

UP WITH 1-F/S DPR

AT FLOOR

10"x6"

B-01 B-02

14" x 12"

SUPPLY UP

14" x 12"

RETURN UP

4-F/S DPR

MH101-BD

1-P1 1-P2

1-AS1

1-P3

1-P4

(BELOW)

2 1/2" HHWS

2 1/2" HHWR

2 1/2"

HHWS/HHWR UP

1 1/4" NG

3/4" NG

3/4" NG

3/4" NG

3/4" NG

1 1/4" DN FROM NEW GAS METER

ABOVE. CONTRACTOR TO PROVIDE

2 PSI OUTLET PRESSURE

1610 CFH

150 FT RUN

3/4" NG UP

TO ROOF

SR-2

285 CFM

SR-2

285 CFM

SR-2

280 CFM

SR-1

150 CFM

RG-4

150 CFM

16"x8"

36"x12"

"x

16"x8"

16"x8"

16"x8"

RG-4

RG-4

425 CFM

RG-4

425 CFM

RG-4

410 CFM

RG-4

400 CFM

1-ET1

1"

1"

1/2" HHWS

1/2" HHWR

3/4" HHWS

3/4" HHWR

KEY NOTES

1 PROVIDE 37 GPM, 400 MBH INPUT, 376 MBH OUTPUT, 94 % EFF, 1.5 FLA, SINGLE PHASE, 120 VOLT

CONDENSING BOILER.

2 4" BOILER FLUE ROUTED TO THE OUTSIDE PER MANUFACTURER'S SIDE VENTING INSTALLTION

INSTRUCTIONS WITH PROPER TERMINATION.

3 4" BOILER AIR INTAKE ROUTED TO THE OUTSIDE PER MANUFACTURER'S SIDE VENTING

INSTALLTION INSTRUCTIONS WITH PROPER TERMINATION.

4 PROVIDE 37 GPM, HEAD - 25 FT, 3/4 HP, SINGLE PHASE, 208 VOLT, ECM MOTOR INLINE PUMP.

5 PROVIDE 3 IN., 55 GPM FULL FLOW TANGENTIAL AIR SEPARATOR.

6 PROVIDE 55 GPM, HEAD - 50 FT, 2 HP, VFD, 3 PHASE, 208 VOLT INLINE PUMP.

ELECTRICAL KEYNOTES

1. REFER TO DRAWING EP100 FOR SCOPE OF BASE BID ELECTRICAL WORK. REMOVE THE

FOLLOWING ELECTRICAL CONNECTIONS AND ASSOCIATED CONTROLS FOR EQUIPMENT BEING

REMOVED AND/OR RELOCATED AS PART OF BID DEDUCT(S).

a.1-SF1 b.1-SF2 c.1-SF3 d.1-EF1 e.1-RF1

f. 1-ERV-1

2. REMOVE ELECTRICAL CONNECTION TO ONE FIRE SMOKE DAMPER AS PART OF BID DEDUCT .

3. PROVIDE UNIFORM LIGHTING LAYOUT IN ROOM WHERE MECHANICAL EQUIPMENT BEING REMOVED

AS PART OF BID DEDUCT NO LONGER INHIBITS LIGHT FIXTURE INSTALLATION.

PLUMBING NOTES

1.) REFER TO DRAWING PL100 AND PL110 FOR SCOPE OF BASE BID PLUMBING WORK. REMOVE THE

FOLLOWING NATURAL GAS CONNECTIONS AND ASSOCIATED ACCCESSORIES FOR EQUIPMENT

BEING REMOVED AND/OR RELOCATED AS PART OF BID DEDUCT(S).

a. B-01

b. B-02

2.) PROVIDE 400 CFH TO B-01 AND 400 CFH TO B-02. REFER TO DETAIL 8/PL400 FOR NATURAL GAS

CONNECTION TO EQUIPMENT.

FIRST FLOOR

816'-0"

SECOND FLOOR

829'-4"

ROOF

856'-0"

THIRD FLOOR

842'-8"

BASEMENT FLOOR

801'-0"

D

T.O.S. LOW POINT

856'-0"

"x

"x

"8

"x

"x

"x

18"x18"

12"x14"

12"x14" 28"x20"

"x

"x

"x

"x

28"x20"

28"x20"

"x

"x

S A

R A

S A

R A

E A

1-RTU-1

52" x 12"

52" x 12"

52" x 12"

1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222

SSOE, Inc.

D A

T E

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

VA ANN ARBOR MEDICAL CENTER CAMPUS

PROJECT #: 015-01361-00

BIDS SUBMISSION_REVISED

C A u to d e s k \R e v it \0

M

S

S O

E B id D e d u c t_

.r v t

/9

/2

:5

:4

A

M

Scale: As indicated

MH101-BD

HVAC BASEMENT PLAN - BID DEDUCT

ALTERNATE

GOTWALD

506-329CLINICAL & ADMINISTRATIVE

BUILDING

WILSON04-12-18

114 148

N

SCALE: 3/16" = 1'-0"

HVAC BASEMENT PLAN - BID DEDUCT ALTERNATE

SCALE: 1/4" = 1'-0"MH101-BD

1 SECTION - DUCT RISER - BID DEDUCT ALTERNATE

ASST CHIEF MAS OFF

VESTIBULE

MEN'S TOILET

HAC

318 IT

ELECTRICAL

HBU SUPRVISOR

CHIEF MAS OFFICER

MED RECORDS

SUPERVISOR

STAIRS

S-1

ELEVATOR

E-1

STAIRS

S-2

COFFEE

OPEN OFFICE

OPEN OFFICE

CORRIDOR

"x

ER-2

210 CFM

ER-3

330 CFM

ELEVATOR LOBBY

CONF. ROOM

CODING SUPERVISOR

OFFICE

ADMINISTRATIVE

OFFICER

WOMEN'S TOILET

A B C D

H

E

4.2

J

2.8

4.8

G

5.4

F

52"x12"

FPB-03-5

FPB-03-8

FPB-03-3

13-F/S DPR

12-F/S DPR

26"x22"

ER-2

210 CFM

18"x18"

"x

ER-1

50 CFM

11-F/S DPR

18" x 16" DN

FP-03-1

6"x6"

56" x 20" DN 56" x 24" UP

TO 1-RTU-1

44" x 24" DN 54" x 24" UP

TO 1-RTU-1

"x

MH101-BD

SCANNING SUPV

RECORD MANAGER

OFFICER

NON-VA CARE SUPV

OPEN OFFICE

3/4" NG RISER

20" x 20" UP

TO 1-RTU-1

20"x20"

10"x10"

OPEN OFFICE

1 1/2" HHWS/

HHWR DN

1" HHWS

1" HHWR

1 1/4" HHWS

1 1/4" HHWR

1" HHWR

1" HHWS

1" HHWR

1" HHWS

1" HHWS

1" HHWR

1 1/4" HHWS

1 1/4" HHWR

1" HHWS

1" HHWR

GENERAL NOTES

1.) ALL TYPES OF TERMINAL UNITS SHALL BE INSTALLED PER DETAIL 2 ON MH501.

2.) ALL EXHAUST BRANCHES SHALL BE INSTALLED PER DETAIL 1 ON MH501

BID DEDUCT KEY NOTES

1 EQUIPMENT TO PROVIDE HEAT UNDER BID DEDUCT ALT #7

1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222

SSOE, Inc.

D A

T E

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

VA ANN ARBOR MEDICAL CENTER CAMPUS

PROJECT #: 015-01361-00

BIDS SUBMISSION_REVISED

C A u to d e s k \R e v it \0

M

S

S O

E B id D e d u c t_

.r v t

/9

/2

:5

:5

A

M

Scale: As indicated

MH131-BD

HVAC THIRD FLOOR PLAN - BID DEDUCT

ALTERNATE

GOTWALD

506-329CLINICAL & ADMINISTRATIVE

BUILDING

WILSON04-12-18

115 148

N

SCALE: 3/16" = 1'-0"

THIRD FLOOR HVAC PLAN - BID DEDUCT ALTERNATE

A

B

B

C

C

D

D

6 6

5 5

3 3

2 2

H

HE

E

4.2

4.2

4 4

J

J

2.8

2.8

4.8

4.8

G

G

5.45.4

F

F

K

K

MH101-BD

1-RTU-1

"x

"x

3/4" NG 3/4" NG RISER FROM BELOW

ELECTRICAL KEY NOTES

1.) REFER TO DRAWING EP140 FOR SCOPE OF BASE BID ELECTRICAL WORK. REMOVE THE FOLLOWING ELECTRICAL CONNECTIONS AND ASSOCIATED CONTROLS FOR EQUIPMENT BEING REMOVED AND/OR

RELOCATED AS PART OF BID DEDUCT(S).

a. 1-H1

b. ACCU-01

2.) PROVIDE 200A, 480V, 3P DISCONNECT SWITCH WITH 150A FUSES IN NEMA 3R ENCLOSURE. FEED

FROM NEW 150A, 3P CIRCUIT BREAKER IN PANEL 4-MDP-BA VIA 3#1/0,1#6/G,1-1/2"C.

PLUMBING NOTES

1.) PROVIDE 810 CFH TO RTU-01. REFER TO DETAIL 8/PL400 FOR NATURAL GAS CONNECTION

TO EQUIPMENT.

1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222

SSOE, Inc.

D A T E

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

VA ANN ARBOR MEDICAL CENTER CAMPUS

PROJECT #: 015-01361-00

BIDS SUBMISSION_REVISED

C A u to d e s k \R e v it \0 M S S O E B id D e d u c t_ .r v t

/9 /2 :5 :0 A M

Scale: As indicated

MH141-BD

HVAC ROOF PLAN - BID DEDUCT

ALTERNATE

GOTWALD

506-329CLINICAL & ADMINISTRATIVE

BUILDING

WILSON04-12-18

116 148

N

SCALE: 3/16" = 1'-0"

ROOF HVAC PLAN - BID DEDUCT ALTERNATE

3. FAN SELECTION TOTAL STATIC PRESSURE TO INCLUDE DIRTY FILTER ALLOWANCE.

2. PROVIDE MERV 13 FILTER UPSTREAM OF COOLING COIL. PRESSURE DROP: 0.35 IN WG CLEAN, 0.75 IN WG DIRTY

1. PROVIDE MERV 8 FILTER UPSTREAM OF HEAT WHEEL. PRESSURE DROP: 0.24 IN WG CLEAN, 0.59 IN WG DIRTY

NOTES

WINTER 3500 0.0 0.0 57.3 48.8 3500 13.9 13.8

RTU-1 ROOF 18000 3500 1.5 2 x 10 18000 1.24 2 x 5

SUMMER 3500 95.0 75.0 78.3 64.8 3500 91.6 72.8

R-410A 75.6 62.6 51.1 50.9 0.43 810 648 2 460/3/60 134 7658

DB (°F) WB (°F) DB (°F) WB (°F) DB (°F) WB (°F) DB (°F) WB (°F) DB (°F) WB (°F)

SEASON

AIRFLOW

(CFM)

EAT LAT AIRFLOW

(CFM)

EAT

TOTAL

AIRFLOW

(CFM)

OUTDOOR

AIRFLOW

MIN/MAX

(CFM)

ESP

(IN WG)

MOTOR

(HP)

MIN/MAX

AIRFLOW

(CFM)

ESP

(IN WG)

MOTOR

(HP)

OUTSIDE AIR EXHAUST

REFRIG

EAT LAT AIR PD

(IN WG)

INPUT

(MBH)

OUTPUT

(MBH)

NAT GAS

PRESSURE

(PSIG)

V/PH/HZ MCA

MARK

LOCATION/

SERVICE

SUPPLY FAN DATA EXHAUST/RELIEF FAN DATA ENERGY RECOVERY COOLING CAPACITY (500 FPM MAX FACE VELOCITY) HEATING CAPACITY ELECTRICAL

WEIGHT

(LBS)

REMARKS

ROOFTOP UNIT SCHEDULE

SEQUENCE OF OPERATION

SYSTEM OPERATING MODES: THE BUILDING AUTOMATION SYSTEM (BAS) SHALL INCLUDE A

USER-ADJUSTABLE TIME-OF-DAY SCHEDULE TO DEFINE WHEN THE VARIOUS AREAS OF THE

FACILITY ARE EXPECTED TO BE OCCUPIED VERSUS UNOCCUPIED. THEN, BASED ON CURRENT

ZONE CONDITIONS, THE BAS DETERMINES THE CURRENT SYSTEM OPERATING MODE.

• OCCUPIED HEAT/COOL

DURING THE OCCUPIED MODE, THE ROOFTOP UNIT (RTU) MODULATES THE SUPPLY FAN TO

DELIVER THE REQUIRED AIRFLOW TO THE ZONES, POSITIONS THE OUTDOOR-AIR DAMPER TO

BRING IN REQUIRED AMOUNT OF VENTILATION, ENABLES THE HEAT WHEEL TO WHEN THE UNIT

IS NOT IN ECONOMIZER, MODULATES THE RELIEF FAN(S) TO MAINTAIN BUILDING PRESSURE AT

THE DESIRED SETPOINT, AND CYCLES THE COMPRESSORS, MODULATES (OR STAGES) THE

SOURCE OF HEAT, AND/OR ENABLES THE AIRSIDE ECONOMIZER TO DISCHARGE AIR AT THE

DESIRED SETPOINT.

• UNOCCUPIED HEAT/COOL

DURING THE UNOCCUPIED MODE, THE RTU SHUTS OFF WITH THE RETURN AIR DAMPER OPEN

AND THE OUTDOOR-AIR DAMPER AND RELIEF DAMPER CLOSED.

• MORNING WARM-UP/PRE-COOL

DURING THE MORNING WARM-UP/PRE-COOL MODE, EACH VAV TERMINAL UNIT VARIES PRIMARY

AIRFLOW, CYCLES A TERMINAL FAN (IF EQUIPPED), AND/OR MODULATES (OR STAGES) A LOCAL

HEAT SOURCE (IF EQUIPPED) TO RAISE/LOWER THE ZONE TEMPERATURE TO THE OCCUPIED

SETPOINT (HEATING OR COOLING), AND THEN CLOSES. MEANWHILE, THE RTU MODULATES THE

SUPPLY FAN TO DELIVER THE REQUIRED AIRFLOW TO THE ZONES, CLOSES THE OUTDOOR-AIR

DAMPER, CLOSES THE CENTRAL RELIEF DAMPER (OR SHUTS OFF THE CENTRAL RELIEF FAN),

AND CYCLES THE COMPRESSORS OR MODULATES (OR STAGES) THE SOURCE OF HEAT TO

DISCHARGE AIR AT THE DESIRED SETPOINT.

FOR A COLD-AIR VAV SYSTEM, IF THE RETURN AIR DEW POINT TEMPERATURE IS HIGHER THAN

55°F (ADJ) DURING MORNING PRE-COOL MODE, THE DISCHARGE-AIR TEMPERATURE SETPOINT

WILL BE RESET EVERY 10 MINUTES SO THAT IT IS ONLY 2°F (ADJ) BELOW THE CURRENT

RETURN AIR DEW POINT TEMPERATURE.

OPTIMIZED SYSTEM-LEVEL CONTROL SEQUENCES: THE BAS SHALL PERFORM THE FOLLOWING

OPTIMIZED SYSTEM-LEVEL CONTROL STRATEGIES:

• OPTIMAL START

THE BAS SHALL INITIATE OPTIMAL START MODE SUCH THAT THE RTU IS STARTED AND VAV

BOXES ARE ENABLED TO ALLOW THE ZONE TEMPERATURE TO REACH THE OCCUPIED HEATING

OR COOLING SETPOINT PRIOR TO SCHEDULED OCCUPANCY. THE SYSTEM SHALL WAIT AS

LONG AS POSSIBLE BEFORE STARTING, SO THAT THE TEMPERATURE IN EACH ZONE REACHES

THE OCCUPIED SETPOINT JUST IN TIME FOR SCHEDULED OCCUPANCY.

• OPTIMAL STOP

THE BAS SHALL INITIATE OPTIMAL STOP MODE SUCH THAT COOLING OR HEATING IS DISABLED

SO THAT THE ZONE TEMPERATURE DOES NOT DRIFT BEYOND THE OCCUPIED STANDBY

SETPOINT BY THE END OF THE SCHEDULED OCCUPANCY PERIOD. THE RTU SUPPLY FAN SHALL

CONTINUE OPERATING, AND VENTILATION CONTROL SHALL CONTINUE, THROUGH THE END OF

THE SCHEDULED OCCUPANCY PERIOD.

• UNOCCUPIED ECONOMIZING (NIGHT PURGE)

BETWEEN 4:00 AM (ADJ.) AND 6:00 AM (ADJ), THE BAS SHALL INITIATE UNOCCUPIED

ECONOMIZING MODE IF THE CURRENT ZONE TEMPERATURE IS AT LEAST 1°F WARMER THAN

THE OCCUPIED COOLING SETPOINT AND THE OUTDOOR DRY-BULB TEMPERATURE IS MORE

THAN 15°F (ADJ) COOLER THAN THE CURRENT ZONE TEMPERATURE. WHEN INITIATED, THE RTU

IS STARTED (OA DAMPER FULLY OPEN, COMPRESSORS OFF) AND VAV BOXES ARE ENABLED TO

ALLOW THE ZONE TEMPERATURE TO COOL TO THE OCCUPIED COOLING SETPOINT.

• OPTIMIZED CONTROL OF SUPPLY DUCT STATIC PRESSURE (FAN-PRESSURE OPTIMIZATION)

AT A FREQUENCY OF ONCE EVERY 10 MINUTES, THE BAS SHALL MONITOR THE DAMPER

POSITION OF ALL VAV TERMINAL UNITS. THE BAS SHALL CALCULATE A NEW SUPPLY FAN DUCT

STATIC PRESSURE SETPOINT BASED ON THE POSITION OF THE FURTHEST-OPEN VAV DAMPER,

AND SEND THIS NEWLY-CALCULATED SETPOINT TO THE RTU CONTROLLER. WHEN ANY VAV

DAMPER IS MORE THAN 75% (ADJ) OPEN, THE SUPPLY FAN DUCT STATIC PRESSURE SETPOINT

SHALL BE RESET UPWARD BY 5% UNTIL NO DAMPER IS MORE THAN 75% (ADJ) OPEN OR THE

STATIC PRESSURE SETPOINT HAS RESET TO THE MAXIMUM SETTING. WHEN ALL VAV DAMPERS

ARE LESS THAN 65% (ADJ) OPEN, THE SUPPLY FAN DUCT STATIC PRESSURE SETPOINT SHALL

BE RESET DOWNWARD BY 5% UNTIL AT LEAST ONE DAMPER IS MORE THAN 65% (ADJ) OPEN OR

THE STATIC PRESSURE SETPOINT HAS RESET TO THE MINIMUM SETTING.

• OPTIMIZED CONTROL OF SUPPLY AIR TEMPERATURE (SAT RESET)

AT A FREQUENCY OF ONCE EVERY 10 MINUTES, THE BAS SHALL MONITOR THE OUTDOOR DRY-

BULB TEMPERATURE, AS WELL AS THE ZONE TEMPERATURE AND DAMPER POSITION OF ALL VAV

TERMINAL UNITS. THE BAS SHALL CALCULATE A NEW SAT SETPOINT BASED ON CURRENT

OUTDOOR AIR (OA) TEMPERATURE, AND SEND THIS NEWLY-CALCULATED SAT SETPOINT TO THE

RTU CONTROLLER. WHEN THE OA TEMPERATURE IS WARMER THAN 65°F (ADJ), THE SAT

SETPOINT SHALL BE 55°F (ADJ). WHEN THE OA TEMPERATURE IS COLDER THAN 55°F (ADJ), THE SAT SETPOINT SHALL BE 60°F (ADJ). WHEN THE OA TEMPERATURE IS BETWEEN 55°F (ADJ) AND 65°F (ADJ), THE SAT SETPOINT SHALL BE RESET PROPORTIONALLY BETWEEN 55°F (ADJ) AND 60° F (ADJ). IF AT LEAST TWO (ADJ) ZONES HAVE BOTH 1) A VAV DAMPER THAT IS MORE THAN 75%

OPEN, AND 2) A CURRENT ZONE TEMPERATURE THAT IS HIGHER THAN THE CURRENT COOLING

SETPOINT, THEN THE SAT SETPOINT SHALL RETURN TO 55°F (ADJ) IF THE OUTDOOR DEW POINT IS HIGHER THAN 60°F (ADJ), THIS SAT RESET SEQUENCE SHALL BE SUSPENDED AND THE SAT

SETPOINT SHALL BE RESET TO 55°F (ADJ) UNTIL OUTDOOR DEW POINT DROPS BELOW 57°F

(ADJ).

• OPTIMIZED CONTROL OF VENTILATION (VENTILATION OPTIMIZATION)

THE ACTUAL OUTDOOR AIRFLOW SHALL BE SENSED AT THE OUTDOOR AIR INTAKE OF THE RTU,

AND CONTROLLED TO AN AIRFLOW SETPOINT DETERMINED ACCORDING TO ASHRAE STANDARD

62.1. WHEN THE BAS TIME-OF-DAY SCHEDULE INDICATES THAT A ZONE IS UNOCCUPIED, THE

REQUIRED OUTDOOR AIRFLOW FOR THAT ZONE SHALL BE ZERO. WHEN THE SCHEDULE

INDICATES THAT A ZONE IS OCCUPIED, THE REQUIRED OUTDOOR AIRFLOW FOR THAT ZONE

SHALL EQUAL THE DESIGN OUTDOOR AIRFLOW, UNLESS THE ZONE IS EQUIPPED WITH

OCCUPANCY SENSOR AND/OR A CARBON DIOXIDE (CO¬2) SENSOR, OR USES A TIME-OF-DAY

VENTILATION SCHEDULE, TO REDUCE THE REQUIRED OUTDOOR AIRFLOW DURING PERIODS

OF PARTIAL OCCUPANCY. THE REQUIRED OUTDOOR-AIR FRACTION (CURRENT REQUIRED

OUTDOOR AIRFLOW DIVIDED BY THE CURRENT PRIMARY AIRFLOW) SHALL BE CONTINUOUSLY

CALCULATED FOR EACH ZONE (VAV TERMINAL UNIT). AT A FREQUENCY OF ONCE EVERY 10

MINUTES, THE BAS SHALL GATHER THIS DATA FROM ALL VAV TERMINAL UNITS, CALCULATE THE

MINIMUM REQUIRED OUTDOOR AIRFLOW FOR THE SYSTEM ACCORDING TO ASHRAE 62.1, AND

SEND THIS NEWLY-CALCULATED OUTDOOR AIRFLOW SETPOINT TO THE RTU CONTROLLER.

R

B

C

A

B

C

D

E

OS

SWITCH, CEILING MOUNTED PULL

SWITCH

BLANK = SINGLE POLE

2 = DOUBLE POLE

3 = THREE-WAY

4 = FOUR-WAY

D = DIMMER

K = KEY OPERATED

LV= LOW VOLTAGE

L = LOCK

LM= LOW VOLTAGE MASTER

P = WITH PILOT LIGHT

PB= PUSH BUTTON STATION

RC= REMOTE CONTROL

T = TIMER OPERATED

WP= WEATHER PROOF

X = EXPLOSION PROOF

OS= STAND ALONE OCCUPANCY SENSOR

RECESSED DOWNLIGHT FIXTURE, LETTER INDICATES TYPE.

LIGHT FIXTURE, RECESSED, 2'x4' [610x1220mm];

LETTER INDICATES TYPE.

LIGHT FIXTURE, RECESSED, 1'x4' [305x1220mm];

LETTER INDICATES TYPE.

ELECTRICAL SYMBOLS - LIGHTING PLAN

LIGHT FIXTURE, RECESSED, 1'x8' [305x2439mm]; LETTER INDICATES TYPE.

LIGHT FIXTURE, SURFACE MOUNTED, 2'x4' [610x1220mm];

LETTER INDICATES TYPE.

LIGHT FIXTURE, SURFACE, 1'x4' [305x1220mm];

LETTER INDICATES TYPE.

LIGHT FIXTURE, SURFACE MOUNTED, 1'x8' [305x2439mm]; LETTER INDICATES TYPE.

LIGHT FIXTURE, EMERGENCY;

LETTER INDICATES TYPE.

LIGHTING, ONE HEAD EMERGENCY BATTERY POWER

STREET LIGHT WITH BRACKET

LIGHT POLE, ONE MAST ARM, ONE LUMINAIRE

LIGHT POLE, POST TOP MOUNT LUMINAIRE

LIGHT POLE, ONE LUMINAIRE

LIGHTING, EXTERIOR BUILDING

LIGHTING, TWO HEAD EMERGENCY BATTERY POWER

EXTERIOR FLOOD LIGHT

EXIT SIGN, WALL MOUNTED WITH DIRECTIONAL ARROWS AND

FACES AS SHOWN AS HATCHED AREA

EXIT SIGN, CEILING MOUNTED WITH DIRECTIONAL ARROWS AND

FACES AS SHOWN AS HATHED AREA

LIGHT FIXTURE, RECESSED, 2'x2' [610x610mm]; LETTER

INDICATES TYPE.

LIGHT FIXTURE, SURFACE MOUNTED, 2'x2' [610x610mm]; LETTER INDICATES TYPE.

LIGHT FIXTURE, STRIP/INDUSTRIAL; LETTER INDICATES TYPE.

LIGHT FIXTURE, WALL MOUNTED

LIGHT FIXTURE, BOLLARD

LIGHT FIXTURE, DIRECTIONAL

LIGHT POLE, TWO LUMINAIRES

TIME CLOCK

RECTIFIER, CATHODIC PROTECTION SANITARY

ELECTRICAL STRIP MOLD (OUTLETS ON 2'-0" [610mm] CENTERS OR AS DESIGNATED ON DRAWINGS), MTD 3'-6" [1067mm] AFF OR AS

INDICATED.

3-GANG COMPARTMENT BOX IN FLOOR FOR TELEPHONE, DATA &

RECEPTACLE.

DISCONNECT SWITCH, FUSED

DISCONNECT SWITCH, UNFUSED

STARTER, COMBINATION WITH DISCONNECT SWITCH

STARTER OR MOTOR CONTROLLER

POTHEAD

STRESS CONE

VENTILATOR OR FAN COIL UNIT OUTLET

CONDUIT TERMINATED 6" [152mm] AFF IN STANDARD BOX FOR

EXTENSION TO EQUIPMENT AS DIRECTED.

CONDUIT TERMINATED W/COUPLING (FLUSH W/FINISHED FLOOR) FOR

EXTENSION TO EQUIPMENT AS DIRECTED.

ELECTRICAL SYMBOLS - POWER PLAN

JUNCTION BOX

TRANSFORMER, PLAN

MOTOR, SINGLE-PHASE

MOTOR, THREE-PHASE

WYE CONNECTION

DUCT, CELL FLOOR HEADER

DUCT, TROLLEY

DUCT, UNDERFLOOR JUNCTION BOX

EARTH GROUND

LADDER CABLE TRAY

BRANCH CIRCUIT HOMERUN. LINES INDICATE NUMBER OF CIRCUITS,

NEUTRAL, AND SWITCH LEG CONDUCTORS. ONE SEPARATE GREEN

GROUNDING CONDUCTOR SHALL BE PROVIDED FOR EACH HOMERUN;

NOT SHOWN

PULL BOX

WIREWAY

RIGID CONDUIT LINE = RC

SUBSTATION

BUSWAY

FLOOR OUTLET, DATA COMMUNICATION

OUTLET, DATA COMMUNICATION

PUSH BUTTON

DISTRIBUTION PANEL

LIGHTING PANEL

PANELBOARD CABINET, FLUSH MOUNTED

PANELBOARD CABINET, SURFACE MOUNTED

RECEPTACLE, CLOCK HANGER

RECEPTACLE, DUPLEX

RECEPTACLE, DUPLEX ON EMERGENCY POWER

RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER

RECEPTACLE, QUADRAPLEX

RECEPTACLE, SINGLE

RECEPTACLE, SINGLE WITH SWITCH

RECEPTACLE, SPECIAL PURPOSE

A = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 5-20R.

B = 208V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 6-20R.

C = 120V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 5-30R.

D = 208V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 6-30R.

E = 208V, 60A, 1 PHASE, 3-POLE, 4W, NEMA 14-60R.

F = 208V, 30A, 3 PHASE, 3-POLE 4W, NEMA 15-30R.

G = 208V, 50A, 3 PHASE, 3 POLE, 4W, NEMA 15-30R.

H = 208V, 60A, 3 PHASE, 3 POLE, 4W, NEMA 15-60R.

RECEPTACLE, SWITCHED DUPLEX

DIRECT BURIAL CABLE = DB

POWER DUCT = P

HI VOLTAGE SWITCH ON CONCRETE PAD

LOW VOLTAGE SWITCH ON CONCRETE PAD

DUAL POWER AND TELECOMMUNICATIONS MANHOLE

DROP CORD, SINGLE CONVENIENCE OUTLET, 3-WIRE, GROUNDING

TYPE, 20A, W/#12 CONDUCTORS IN FLEXIBLE CORD (CENTER LINE

OF OUTLET: 6'-6" [1981mm] AFF. MINIMUM).

ELECTRICAL STRIP MOLD (OUTLETS ON 2'-0" [610mm] CENTERS OR AS DESIGNATED ON DRAWINGS), MTD 3'-6" [1067mm] AFF OR AS

INDICATED.

3-GANG COMPARTMENT BOX IN FLOOR FOR TELEPHONE, DATA &

RECEPTACLE.

RELAY; LETTER INDICATES RELAY TYPE

50 = INSTANTANEOUS OVERCURRENT OR RATE-OF-RISE

51 = AC-TIME OVERCURRENT

67 = AC-DIRECTIONAL OVERCURRENT

86 = LOCK OUT

ELECTRICAL SYMBOLS - POWER PLAN

SWITCH

F = FUSED SWITCH K = KEY OPERATED

L = LOCK LM= LOW VOLTAGE MASTER

M = MANUAL MOTOR STARTING MC= MOMENTARY CONTACT

MP= MOTOR SNAP WITH PILOT LIGHT P = WITH PILOT LIGHT

(THERMAL TYPE)

PB= PUSH BUTTON STATION RC= REMOTE CONTROL

WP= WEATHER PROOF X = EXPLOSION PROOF

VARIABLE FREQUENCY DRIVE

1PH SINGLE-PHASE

1P SINGLE POLE

2/C TWO-CONDUCTOR

3/C THREE-CONDUCTOR

3PH THREE-PHASE

4/C FOUR-CONDUCTOR

4W FOUR-WIRE

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAP ALARM ANNUNCIATOR PANEL

AC ALTERNATING CURRENT OR ARMORED CABLE

ACC ACCESSIBLE

ADDL ADDITIONAL

ADJ ADJACENT, ADJOINING

ADO AUTOMATIC DOOR OPENER

AF AMPERE FRAME OR AMP FUSE

AFC ABOVE FINISHED COUNTER, AUTOMATIC

FREQUENCY CONTROL, OR AVAILABLE

FAULT CURRENT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AH AMPERE HOUR

AHJ AUTHORITY HAVING JURISDICTION

AIC AMPERE INTERRUPTING CAPACITY

ALT ALTERNATE

AMB OR A AMBIENT

AMP AMPERE

ARCH ARCHITECT

ASC AMPS SHORT CIRCUIT

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

BAT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISH FLOOR

BIL BASIC INSULATION LEVEL

BLDG BUILDING

BPIP BOILER PLANT INSTRUMENTATION PANEL

BRKR BREAKER

BYP BY PASS

C CONDUIT

CAB CABINET

CALC CALCULATE

CAP CAPACITY

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR

INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER

INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CHW CHILLED WATER

CHWP CHILLED WATER PUMP

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CLF CURRENT LIMITING FUSE

CLG CEILING

CMU CONCRETE MASONRY UNIT

COAX COAX CABLE

COMM COMMUNICATION

COMPT COMPARTMENT

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CU COPPER

CU FT CUBIC FEET

CUR CURRENT

DB DECIBEL OR DIRECT BURIAL

DC DIRECT CURRENT

DCP DIMMER CONTROL PANEL

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLITION

DIAG DIAGRAM

DISC DISCONNECT

DISTR DISTRIBUTION

DISTR PNL DISTRIBUTION PANEL

DMR SW DIMMER SWITCH

DN DOWN

DPDT DOUBLE POLE, DOUBLE THROW

DPST DOUBLE POLE, SINGLE THROW

DRSW DOOR SWITCH

DS DISCONNECT SWITCH

DWG DRAWING

EC EMPTY CONDUIT

EG EQUIPMENT GROUND

EL ELEVATION

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMCP EMERGENCY MONITORING CONTROL

PANEL

EMER EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

EPRF EXPLOSION PROOF

ESMT EASEMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EXIST EXISTING

ELECTRICAL ABBREVIATIONS

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FABL FIRE ALARM BELL

FABX FIRE ALARM BOX

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FI FILM ILLUMINATOR

FIXT FIXTURE

FLA FULL LOAD AMPS

FLEX FLEXIBLE METALLIC CONDUIT

FLT FLOODLIGHT

FLUOR FLUORESCENT

FLUOR FIX FLUORESCENT FIXTURE

FOUTT TELEPHONE FLOOR OUTLET

FP FIRE PROTECTION

FT FEET OR FOOT

FU SW FUSED SWITCH

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

G OR GND GROUND OR GENERATOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GTB GROUND TERMINAL BOX

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HZ HERTZ

IESNA ILLUMINATION ENGINEERING SOCIETY OF

NORTH AMERICA

IMC INTERMEDIATE METAL CONDUIT

INCAND INCANDESCENT

IR INFRARED

IWH INSTANTANEOUS WATER HEATER

J-BOX JUNCTION BOX

kV KILOVOLT kVA KILOVOLT AMPERE kVAH KILOVOLT AMPERE PER HOUR kVAR KILOVOLT AMPERE REACTIVE kW KILOWATT kWH KILOWATT HOUR kWHM KILOWATT HOUR METER

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LM LUMEN

LP LIGHT POLE

LPS LOW PRESSURE SODIUM

LRA LOCKED ROTOR AMPS

LTCP LOCAL TEMPERATURE CONTROL PANEL

LT LIGHT

LTG LIGHTING

LTG PNL LIGHTING PANEL

LTNG LIGHTNING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MC METAL-CLAD

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MG MOTOR GENERATOR

MH MANHOLE

MIN MINIMUM

MOCP MAXIMUM OVERCURRENT PROTECTION

MLO MAIN LUGS ONLY

MT MOUNT

MTD MOUNTED

MTG MOUNTING

MTS MANUAL TRANSFER SWITCH

MV MEDIUM VOLTAGE

MVA MEGAVOLT-AMPERE

MW MEGAWATT MICROWAVE

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NEUT OR N NEUTRAL

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NS NO SCALE

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OL OVERLOAD

P POLE

PA PUBLIC ADDRESS

PB PANELBOARD, PULL BOX, OR

PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT UNIT

PCB POLYCHLORINATED BIPHENYL

PEC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PNL PANEL

POD POWER OPERATED DAMPER

PT POTENTIAL TRANSFORMER

PTRV POWER TYPE ROOF VENTILATION

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

RCP REFLECTED CEILING PLAN

REC RECESSED

RECPT RECEPTACLE

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

REQD REQUIRED

SCC SHORT CIRCUIT CAPACITY

SES SERVICE ENTRANCE SECTION

SD SMOKE DETECTOR

SF SQUARE FOOT (FEET)

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SPEC SPECIFICATION

SPST SINGLE POLE, SINGLE THROW

SURF SURFACE

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

TC TIME CLOCK

TEL TELEPHONE

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TYP TYPICAL

UFD UNDERFLOOR DUCT

UGND UNDERGROUND

UL UNDERWRITERS LABORATORY

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

VA VOLT AMPERE

VAR VOLT AMPERE REACTIVE

VFD VARIABLE FREQUENCY DRIVE

VOLT VOLTAGE

W WATT

WH WATER HEATER

WP WEATHERPROOF

XFER TRANSFER

XFMR TRANSFORMER

DP#__

LP

TC

T

PB

S

S

S

HVS

LVS

P

T

R

VFD

RC

DB

P

W W

B B

C C

J

T T

POKE THRU

FLOOR BOX

POKE THRU

FLOOR BOX

OSB = LUTRON LOS-CDT-2000-WH

OSA = MS-Z101-WH

LVB = LUTRON QSWS2-2BI-WH

LVA = LUTRON QSWS2-1BI-WH

CL CENTER LINE

(R) NEW LOCATION FOR RELOCATED ITEM

A

P

GROUND ROD

COMBINATION MAGNETIC MOTOR STARTER - FULL VOLTAGE TYPE

WITH FUSIBLE DISCONNECT SWITCH

LIGHT FIXTURE, STRIP/INDUSTRIAL EMERGENCY; LETTER INDICATES TYPE.

CEILING MOUNTED OCCUPANCY SENSOR

1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222

SSOE, Inc.

D A

T E

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

VA ANN ARBOR MEDICAL CENTER CAMPUS

PROJECT #: 015-01361-00

BIDS SUBMISSION_REVISED

C A u to d e s k \R e v it \0

E

S

S O

E .r v t

/9

/2

:1 :2

P

M

E000

ELECTRICAL SYMBOLS, LEGEND AND

NOTES

PATERSON

506-329CLINICAL & ADMINISTRATIVE

BUILDING

BUTTS11-15-16

117 148

GENERAL NOTES

A THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS, BUT ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS. THESE DRAWINGS ARE SUPPLEMENTARY TO THE PROJECT SPECIFICATIONS. COORDINATE WITH OTHER TRADES, AND PROVIDE EACH SYSTEM COMPLETE, INCLUDING

ALL NECESSARY COMPONENTS, FITTINGS, AND OFFSETS.

B INSTALL SYSTEMS SUCH THAT CODE REQUIRED WORKING CLEARANCE AND DEDICATED EQUIPMENT SPACE ALONG WITH SERVICE ACCESS SPACE IS PROVIDED AROUND ALL MECHANICAL AND ELECTRICAL EQUIPMENT, AND AROUND ANY COMPONENTS WHICH REQUIRE SERVICE ACCESS.

C COORDINATE AND PROVIDE ACCESS DOORS WITHIN INACCESSIBLE CEILING, SHAFT, AND CHASE AREAS FOR ALL COMPONENTS WHICH REQUIRE SERVICE ACCESS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES AND PARTITION RATINGS. ACCESS DOORS IN FIRE RATED SURFACES SHALL MAINTAIN THE

FIRE RATING OF THE PARTITION.

D PROVIDE ALL MISCELLANEOUS STEEL AND HARDWARE TO SUPPORT ALL DEVICES AND EQUIPMENT AS INDICATED IN THE SPECIFICATIONS.

E REFER TO MECHANICAL/ELECTRICAL SCHEDULE DRAWING(S) FOR ELECTRICAL REQUIREMENTS FOR MECHANICAL EQUIPMENT. PROVIDE ALL CONNECTIONS, STARTERS, DISCONNECTS, ETC. AS INDICATED ON THE SCHEDULES AND WHERE ELSEWHERE NOTED. PROVIDE THE CIRCUIT OF HIGHER AMPACITY WHERE CIRCUIT SIZES ARE SHOWN ON THE ELECTRICAL DRAWINGS THAT DIFFER FROM WHAT IS INDICATED ON THE MECHANICAL SCHEDULES.

F VERIFY REQUIREMENTS OF ALL MECHANICAL EQUIPMENT WITH EQUIPMENT SHOP DRAWINGS PRIOR TO ORDERING MATERIALS. NOTIFY THE ENGINEER OF ANY DISCREPANCIES BETWEEN THE EQUIPMENT SHOP DRAWINGS AND ELECTRICAL DRAWINGS. OBTAIN DIRECTION FROM THE ENGINEER PRIOR TO ORDERING

MATERIALS WHERE DISCREPANCIES EXIST.

G PROVIDE NEW OVERCURRENT PROTECTIVE DEVICES TO MATCH EXISTING EQUIPMENT WHERE NEW OVERCURRENT PROTECTIVE DEVICES ARE REQUIRED TO

SERVE NEW LOADS FROM EXISTING EQUIPMENT.

H TRANSFORMER CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH THE NEC UNLESS NOTED OTHERWISE.

I MOTOR CIRCUIT PROTECTION SHALL BE SIZED IN ACCORDANCE WITH THE NEC UNLESS NOTED OTHERWISE.

J TYPICAL HOMERUN CIRCUIT IS 3/4"C., 2#12 & 1#12 GND (CU), UNLESS OTHERWISE NOTED. SHARED NEUTRALS ARE PROHIBITED. REFER TO THE BRANCH CIRCUIT VOLTAGE DROP TABLE ON THIS DRAWING FOR MAXIMUM DISTANCE FOR BRANCH CIRCUIT WIRING.

K WHERE MULTIPLE SWITCHES, RECEPTACLES, AND OTHER OUTLETS (EXCEPT WALL PHONES) ARE INDICATED PROVIDE MULTI-GANG BACK BOXES WITH GANG

BARRIERS AND A COMMON FACEPLATE FOR ALL SIMILAR DEVICES.

L WHERE DIFFERENT RECESSED ELECTRICAL DEVICES WITH THE SAME MOUNTING HEIGHTS ARE INDICATED SIDE-BY-SIDE, MOUNT THE DEVICES SO THAT THERE IS ONE INCH BETWEEN ADJACENT VERTICAL EDGES OF THE FACEPLATES, UNLESS OTHERWISE NOTED.

M WHERE ELECTRICAL DEVICES WITH DIFFERENT MOUNTING HEIGHTS ARE LOCATED IN THE SAME AREA ALIGN DEVICES VERTICALLY THROUGH THEIR

CENTERLINES.

N REFER TO ARCHITECTURAL ELEVATIONS FOR COORDINATED LOCATIONS OF TYPICAL ELECTRICAL DEVICES. VERIFY MOUNTING HEIGHTS OF ALL OUTLETS.

O TYPICAL MOUNTING HEIGHTS ARE INDICATED ON THE ARCHITECTURAL DRAWINGS. COORDINATE THE MOUNTING HEIGHT OF DEVICES AND EQUIPMENT INDICATED ON THESE DRAWINGS THAT ARE INDICATED AT DIFFERENT MOUNTING HEIGHTS THAN THOSE INDICATED ON THE ARCHITECTURAL DRAWINGS WITH

THE ARCHITECT AND/OR ENGINEER PRIOR TO INSTALLATION.

P COORDINATE THE EXACT LOCATION OF ALL FLOOR BOXES WITH THE FINAL FURNITURE LAYOUT DRAWINGS AND ARCHITECTURAL TRADE.

Q WHERE THE NUMBER OF CURRENT-CARRYING CONDUCTORS IN A RACEWAY EXCEEDS THREE, THE ALLOWABLE AMPACITY OF EACH CONDUCTOR SHALL BE REDUCED AS SHOWN IN THE ADJUSTMENT FACTOR TABLE IN THE NATIONAL ELECTRICAL CODE. LOAD DIVERSITY FACTORS SHALL NOT BE USED IN SIZING

BRANCH CIRCUIT CONDUCTORS.

R CONTRACTOR SHALL PROVIDE UPDATED, TYPED PANEL DIRECTORIES FOR ALL PANELBOARDS MODIFIED DURING DEMOLITION AND/OR CONSTRUCTION. ANY CIRCUITS MADE AVAILABLE DURING DEMOLITION AND NOT RE-USED DURING CONSTRUCTION SHALL BE MARKED "SPARE".

S PROVIDE A DISCONNECTING MEANS FOR ALL LIGHTING FIXTURES PER NEC SECTION 410.130.G.1.

T COORDINATE ANY SHUT DOWN OF EXISTING SERVICES AND EQUIPMENT THAT ARE REMAINING IN USE WITH THE OWNER'S REPRESENTATIVE. WHERE EXISTING BUILDING SERVICE IS REQUIRED TO BE SHUT DOWN, INCLUDE ALL ASSOCIATED OVERTIME COST TO PERFORM THIS WORK DURING WEEKENDS AND EVENINGS, INCLUDE ALL COSTS FOR PROVIDING TEMPORARY POWER WHERE SHUT DOWNS MUST OCCUR FOR PERIODS LONGER THAN THESE HOURS. COORDINATE

ELECTRICAL SHUT DOWNS WITH THE OWNER 72 HOURS PRIOR TO SHUT DOWN.

U ALL EXISTING 2'X4' AND 2'X2' LED LUMINAIRES LOCATED IN EXISTING BUILDING #4 BEING DEMOLISHED SHALL BE REMOVED, WRAPPED TO PROVIDE PROTECTION FROM DAMAGE, AND TRANSPORTED TO AN AREA DESIGNATED BY THE VA FOR STORAGE. THESE FIXTURES SHALL BE INSTALLED IN NEW BUILDING #4 AS

INDICATED IN THESE DOCUMENTS FOR FIXTURES DENOTED WITH (R).

BRANCH CIRCUIT VOLTAGE DROP TABLE

AWG

#12

#10

#8

120V, 20A CIRCUIT

65 FEET

105 FEET

160 FEET

277V, 20A CIRCUIT

150 FEET

245 FEET

375 FEET

DESIGN DEVELOPMENT SUBMISSION 1 04-19-16

DESIGN DEVELOPMENT SUBMISSION 2 06-10-16

95% CONSTRUCTION DOCUMENTS

SUBMISSION

11-15-16

1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222

SSOE, Inc.

D A

T E

FULLY SPRINKLERED

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

VA ANN ARBOR MEDICAL CENTER CAMPUS

PROJECT #: 015-01361-00

BIDS SUBMISSION_REVISED

C A u to d e s k \R e v it \0

E

S

S O

E .r v t

/9

/2

:1 :2

P

M

E001

SCHEDULES AND NOTES

PATERSON

506-329CLINICAL & ADMINISTRATIVE

BUILDING

BUTTS11-15-16

118 148

LIGHTING FIXTURE SCHEDULE

TYPE LAMPS DESCRIPTION VOLTAGE MANUFACTURER (BASIS OF DESIGN IS LISTED) APPARENT LOAD

L1 3500K LED 2' x 4' LED LAY-IN TROFFER WITH: 4000 LUMENS; STEEL HOUSING; WHITE POWDER COAT ONE-PIECE LOWER REFLECTOR; T-BAR CLIPS; 0-10V DIMMABLE DRIVER WIRED FOR DIMMING. 120 V CREE LIGHTING CAT. NO. CR24-40L-35K-10V OR

ENGINEER/VA APPROVED EQUIVALENT

40 VA

L1A 3500K LED 2' x 4' LED LAY-IN TROFFER WITH: 5000 LUMENS; STEEL HOUSING; WHITE POWDER COAT ONE-PIECE LOWER REFLECTOR; T-BAR CLIPS; 0-10V DIMMABLE DRIVER WIRED FOR DIMMING. 120 V CREE LIGHTING CAT. NO. CR24-50L-35K-10V OR

ENGINEER/VA APPROVED EQUIVALENT

50 VA

L1AE 3500K LED SAME AS FIXTURE TYPE 'L1A' EXCEPT COMPLETE WITH 1400 LUMENS EMERGENCY BATTERY BACKUP. 120 V CREE LIGHTING CAT. NO. CR24-50L-35K-10V-EB14 OR

ENGINEER/VA APPROVED EQUIVALENT

50 VA

L1E 3500K LED SAME AS FIXTURE TYPE 'L1' EXCEPT COMPLETE WITH 1400 LUMENS EMERGENCY BATTERY BACKUP. 120 V CREE LIGHTING CAT. NO. CR24-40L-35K-10V-EB14 OR

ENGINEER/VA APPROVED EQUIVALENT

40 VA

L2 3500K LED 2' x 2' LED LAY-IN TROFFER WITH: 3200 LUMENS; STEEL HOUSING; WHITE POWDER COAT ONE-PIECE LOWER REFLECTOR; T-BAR CLIPS; 0-10V DIMMABLE DRIVER WIRED FOR DIMMING. 120 V CREE LIGHTING CAT. NO. CR22-32L-35K-10V OR

ENGINEER/VA APPROVED EQUIVALENT

32 VA

L2E 3500K LED SAME AS FIXTURE TYPE 'L2' EXCEPT COMPLETE WITH 1400 LUMENS EMERGENCY BATTERY BACKUP. 120 V CREE LIGHTING CAT. NO. CR22-32L-35K-10V-EB14 OR

ENGINEER/VA APPROVED EQUIVALENT

32 VA

L3E 3500K LED 4' WALL MOUNT LED FIXTURE WITH: 4000 LUMENS MIN.; STEEL HOUSING, IMPACT MODIFIED LINEAR FACETED REFRACTOR; 0-10V DIMMING DRIVER WIRED FOR NON-DIMMING. COMPLETE WITH 1400 LUMENS

EMERGENCY BATTERY BACKUP.

120 V LITHONIA LIGHTING CAT. NO.

WL4-40L-EZ1-LP835-EL14L OR ENGINEER/VA

APPROVED EQUIVALENT

40 VA

L4 3500K LED 11'-3" LONG, 4" (NOMINAL) RECESSED SLOT, LED LIGHTING FIXTURE MOUNTED IN GYP. CEILING WITH: 381 LUMENS PER FOOT MAX; PRECISION CUT EXTRUDED ALUMINUM BODY; HIGH REFLECTANCE STEEL MATTE WHITE REFLECTOR; FROST WHITE SNAP IN LENS; INTEGRALLY FUSED; 0-10V DIMMABLE DRIVER WIRED FOR NON-DIMMING. VERIFY THE EXACT LENGHTS WITH THE ARCHITECT PRIOR TO ORDERING.

120 V FINELIGHT CAT. NO. HP-4 R-11'

3"-S-8-35-F-120V-SC-SF OR ENGINEER/VA APPROVED

EQUIVALENT

106 VA

L5 3500K LED 6" (NOMINAL) ROUND APERTURE, RECESSED 1500 LUMEN LED DOWNLIGHT WITH: SEMI-SPECULAR OPTICAL SYSTEM AND TRIM FLANGE FINISH; 0-10V DIMMABLE ELECTRONIC POWER SUPPLY WITH OVERLOAD AND SHORT CIRCUIT PROTECTION; REGRESSED LENS; LEDS AND POWER SUPPLY SERVICEABLE FROM BELOW; UL LISTED SUITABLE FOR WET LOCATIONS.

120 V GOTHAM CAT. NO.

EVO-35/15-6AR-MD-LSS-120-EZ10-SF OR

ENGINEER/VA APPROVED EQUIVALENT

19 VA

L5E 3500K LED SAME AS FIXTURE TYPE 'L5' EXCEPT COMPLETE WITH EMERGENCY BATTERY PACK WITH INTEGRAL TEST SWITCH. 120 V GOTHAM CAT. NO.

EVO-35/15-6AR-MD-LSS-120-EZ10-SF/EL OR

ENGINEER/VA APPROVED EQUIVALENT

19 VA

L6 3500K LED 4' LED STRIPLIGHT WITH: 5000 LUMENS; COLD-ROLLED STEEL CONSTRUCTION WITH OPTICAL DROP LENS ASSEMBLY; AIRCRAFT CABLE MOUNTING; WHITE PAINTED FINISH; FIXTURE SHALL HAVE INTEGRAL DRIVER

AND SLOW BLOW FUSE.

120 V LITHONIA LIGHTING CAT. NO.

ZL1D-L48-5000LM-FST-120-35K-80CRI-WH-ZACVH OR

ENGINEER/VA APPROVED EQUIVALENT

42 VA

L6AE 3500K LED SAME AS FIXTURE TYPE 'L6' EXCEPT SURFACE MOUNTED HORIZONTALLY ON WALL AND COMPLETE WITH 1400 LUMENS EMERGENCY BATTERY BACKUP. 120 V LITHONIA LIGHTING CAT. NO.

ZL1D-L48-5000LM-FST-120-35K-80CRI-E7W-WH OR

ENGINEER/VA APPROVED EQUIVALENT

40 VA

L6E 3500K LED SAME AS FIXTURE TYPE 'L6' EXCEPT COMPLETE WITH 1400 LUMENS EMERGENCY BATTERY BACKUP. 120 V LITHONIA LIGHTING CAT. NO.

ZL1D-L48-5000LM-FST-120-35K-80CRI-E7W-WH-ZACVH

OR ENGINEER/VA APPROVED EQUIVALENT

42 VA

L7 3500K LED 4'X4' LED SUSPENDED FIXTURE WITH: 7000 LUMENS; EXTRUDED ALUMINUM RAILS; DIE-CAST CORNERS; FROSTED ACRYLIC OPTICAL DIRECT/INDIRECT DIFFUSER; POWER PROVIDED THROUGH SUSPENSION

SYSTEM;

120 V FOCAL POINT CAT. NO.

FNRP-44-FL50-7000L-35K-1C-UNV-LD1-G-CLV48

33 VA

L8 3000K LED LED DECORATIVE LED CEILING/PENDANT LUMINAIRE WITH: 500LUMEN OUTPUT; SATIN NICKEL FINISH; LATTE CYLINDRICAL GLASS SHADE; DIMMABLE; 59" CABLE LENGTH; 4" ROUND FLUSH CANOPY; SHORT CIRCUIT

PROTECTION.

120 V TECH LIGHTING CAT. NO. 700-MP-MHUD-L-S-LEDS830

OR ENGINEER/VA APPROVED EQUIVALENT

8 VA

L9 3000K LED 25.8"W X 4.8"H DECORATIVE LED WALL SCONCE: 900 LUMENS; HORIZONTAL MOUNT; FROSTED LENS; SATIN NICKEL BODY. 120 V TECH LIGHTING CAT. NO. 700BCMET-S-LED OR

ENGINEER/VA APPROVED EQUIVALENT

20 VA

L10E 3500K LED 4' WALL MOUNT LED FIXTURE WITH: 4000 LUMENS MIN.; STEEL HOUSING, IMPACT MODIFIED LINEAR FACETED REFRACTOR; 0-10V DIMMING DRIVER WIRED FOR DIMMING; INTEGRAL OCCUPANCY SENSOR; WITH 1400

LUMENS EMERGENCY BATTERY BACKUP.

120 V FOCAL POINT CAT. NO.

FDALW-MG-875LF-35K-1C-UNV-SD5-WM-EM-WH-4' OR

ENGINEER/VA APPROVED EQUIVALENT

39 VA

L11 3000K LED 2'-0" LONG, SUREFACE MOUNTED LED UNDERCABINET LIGHT: 504 LUMENS; LOW PROFILE DESIGN; ALUMINUM HOUSING; END CAPS; DIRECT WIRED; SWIVEL HEAD ALLOWS FOR LIGHT TO BE DIRECTED; WHITE

FINISH; PROVIDE ROW CONNECTORS FOR LINEAR RUNS.

120 V LITHONIA LIGHTING CAT. NO. UCLD24-WH OR

ENGINEER/VA APPROVED EQUIVALENT

12 VA

L12E 4000K LED WALL MOUNT WALL PACK WITH: 1959 LUMENS; SINGLE-PIECE DIE-CAST ALUMINUM HOUSING, DIE-CAST DOOR FRAME IS FULLY GASKETED WITH A ONE-PIECE SILICONE GASKET; DARK BRONZE POWDERCOAT FINISH; PRECISION-MOLDED ACRYLIC LENS; WITH EMERGENCY BATTERY BACKUP RATED FOR -20 DEG. OPERATING TEMPERATURE.

120 V LITHONIA LIGHTING CAT. NO.

WST-LED-1-10A700/40K-SR4-120-SF/ELCW-DDBXD OR

ENGINEER/VA APPROVED EQUIVALENT

24 VA

L13 4100K LED LED FLOOD LIGHT FIXTURE WITH: 1300 LUMENS; DIE-CAST ALUMINUM HOUSING; ARCHITECTURAL JUNCTION BOX WITH DARK BRONZE FINISH; FROSTED FILTER; VERY WIDE FLOOD DISTRIBUTION; DARK BRONZE

POWDER COAT FINISH; DIMMING DRIVER;

120 V HYDREL CAT. NO.

TPS1-18LED-WHT41K-MVOLT-VWFL-YM-ARTL-FRF-LDI

M-LP-DDB OR ENGINEER/VA APPROVED EQUIVALENT

34 VA

L14 4100K LED LED FLOODLIGHT FIXTURE WITH: 1600 LUMENS; DIE-CAST ALUMINUM HOUSING; ARCHITECTURAL JUNCTION BOX WITH DARK BRONZE FINISH; FROSTED FILTER; WIDE FLOOD DISTRIBUTION; DARK BRONZE POWDER

COAT FINISH; DIMMING DRIVER;

120 V HYDREL CAT. NO.

TPS1-18LED-WHT41K-MVOLT-WFL-YM-ARTL-FRF-LDIM

-LP-DDB OR ENGINEER/VA APPROVED EQUIVALENT

34 VA

L15 4000K LED LED BOLLARD FIXTURE WITH; 1500 LUMENS; ALUMINUM HOUSING; FROSTED BOROSILICATE GLASS LENS; FORWARD THROW OPTICS; DARK BRONZE POWDER COAT FINISH; DIMMING DRIVER; 120 V HYDREL CAT. NO.

3110C-H42-8C0B-40K-120-FT-LDIM-DDB OR

ENGINEER/VA APPROVED EQUIVALENT

74 VA

X1 LED RECESSED MOUNTED L.E.D. EXIT SIGN WITH: BRUSHED ALUMINUM FINISH; CLEAR ACRYLIC PANEL; SINGLE FACE; RED LETTERING; L.E.D.'S MOUNTED ON A PRINTED CIRCUIT BOARD; NICKEL CADMIUM BATTERY

PACK; SELF-DIAGNOSTICS; *PROVIDE WM OPTION WHERE WALL MOUNTED.

120 V LITHONIA CAT. NO. EDGR-1-R-EL/SD-WM* OR

ENGINEER/VA APPROVED EQUIVALENT

3 VA

X2 LED RECESSED MOUNTED L.E.D. EXIT SIGN WITH: BRUSHED ALUMINUM FINISH; MIRRORED ACRYLIC PANEL; DOUBLE FACE; RED LETTERING; L.E.D.'S MOUNTED ON A PRINTED CIRCUIT BOARD; NICKEL CADMIUM

BATTERY PACK; SELF-DIAGNOSTICS.

120 V LITHONIA CAT. NO. EDGR-2-RMR-EL/SD OR

ENGINEER/VA APPROVED EQUIVALENT

6 VA

FLOOD LIGHTS PHOTOCELL DIMMABLE DUSK DAWN ALL 100%

BOLLARDS PHOTOCELL DIMMABLE DUSK DAWN ALL 100%

REAR EXIT PHOTOCELL DIMMABLE DUSK DAWN ALL 100%

FRONT CANOPY PHOTOCELL DIMMABLE DUSK DAWN ALL 100%

EXTERIOR

S-2 OCCUPANCY SENSOR STEP DIMMING ALWAYS - ALL 100%/50% DIM TO 50% WHEN NO OCCUPANCY

S-1 OCCUPANCY SENSOR STEP DIMMING ALWAYS - ALL 100%/50% DIM TO 50% WHEN NO OCCUPANCY

STAIRS

CONFERENCE ROOM OCCUPANCY SENSOR DIMMABLE - - - LAST LOCAL DIMMABLE OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

ELEVATOR LOBBY TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL ON/OFF OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

RECEPTION PENDANTS TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL ON/OFF OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH; DIMMER CONTROL IN ELECTRICAL CLOSET

CORRIDORS TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL ON/OFF OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

OPEN OFFICE AREAS TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL ON/OFF OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

THIRD FLOOR

CONFERENCE ROOM OCCUPANCY SENSOR DIMMABLE - - - LAST LOCAL DIMMABLE OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

ELEVATOR LOBBY TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

RECEPTION PENDANTS TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH; DIMMER CONTROL IN ELECTRICAL CLOSET

CORRIDORS TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

OPEN OFFICE AREAS TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

SECOND FLOOR

VESTIBULE TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL ON/OFF OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

WAITING TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL DIMMABLE OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

ELEVATOR LOBBY TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL ON/OFF OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

RECEPTION PENDANTS TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL ON/OFF OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH; DIMMER CONTROL IN ELECTRICAL CLOSET

CORRIDORS TIME CLOCK DIMMABLE 7AM 7PM MON-FRI 100% LOCAL ON/OFF OVERRIDE SWITCH WITH TIME-OUT, WARNING FLASH

OPEN OFFICE AREAS TIME CLOCK…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.