36C25018B0795-0001000.docx
DOCX document 304 KB Posted
- Attached to
- Construct Clinical and Admin Building 506-329 Federal contract opportunity
- Solicitation number
- 36C25018B0795
About this file
36C25018B0795 0001 36C25018B0795 0001.docx
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25018B0795-0005000.docx | DOCX document | |
| 36C25018B0795-0004000.docx | DOCX document | |
| 36C25018B0795-0003000.docx | DOCX document | |
| 36C25018B0795-0003001.xlsx | XLSX spreadsheet | |
| 36C25018B0795-0002000.docx | DOCX document | |
| 36C25018B0795-0001002.pdf | ||
| 36C25018B0795-0001001.pdf | ||
| 36C25018B0795-011.pdf | ||
| 36C25018B0795-019.pdf | ||
| 36C25018B0795-017.pdf | ||
| 36C25018B0795-021.pdf | ||
| 36C25018B0795-013.pdf | ||
| 36C25018B0795-009.docx | DOCX document | |
| 36C25018B0795-015.pdf | ||
| 36C25018B0795-018.pdf | ||
| 36C25018B0795-022.docx | DOCX document | |
| 36C25018B0795-014.pdf | ||
| 36C25018B0795-010.pdf | ||
| 36C25018B0795-008.docx | DOCX document | |
| 36C25018B0795-020.pdf | ||
| 36C25018B0795-012.pdf | ||
| 36C25018B0795-007.docx | DOCX document | |
| 36C25018B0795-016.pdf | ||
| 36C25018B0795-000.docx | DOCX document |
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
36C25018B0795 0001
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2.
AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE
OF PAGES
10A. MODIFICATION OF
CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV.
11/2016) is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO:
Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITE M 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES
SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR
43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes r eference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS
ENTERED INTO
PURSUANT TO AUTHORITY OF:
D. OTHER
BY
Contractor
16C. DATE SIGNED
14.
DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME
AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS
OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 09-05-2018 506-18-3-5970-0039 506-329 36C250 Department of Veterans Affairs Network Contracting Office (NCO) 10 24 Frank Lloyd Wright Dr.
Lobby M Suite M2200 Ann Arbor MI 48105 36C250 Department of Veterans Affair Network Contracting Office (NCO) 10 24 Frank Lloyd Wright Dr.
Lobby M Suite M2200 Ann Arbor MI 48105 To all Offerors/Bidders
36C25018B0795 08-08-2018
X X
The purpose of this Amendment is to issue the Pre-Bid Site Visit Agenda, Attendance Sheet, Request for Information (RFI) and responses. Please see attachements and con tinuation pages. All Amendments shall be Acknowledged by offeror on this solicitation or maybe found non-responsive.
Updated Wage Determination attachment.
Bid opening location is unchanged NCO 10 Office, Ann Arbor,MI.
Darrell T. Maxwell Contracting Officer
NCO1015L3-77169
RFI Responses RFI 001 References: Spec. Section 10-33-23
| 1. The use of Submittal Exchange or equal is specified for use on this project. Could you please | advise who’s responsibility it is to provide the web based system for the project? Thank you. |
| Response: The GC shall provide/be responsible for setting up and maintaining Submittal | Exchange for this project. |
RFI 002 References: None
1. Room 001, E-1, 101, 201 and 301 all require sign type C2a, which is not listed in spec book, please provide sign type detail.
Response: See detail for C2A below.
2. Room 100 looks to have at least 2 sign types G6 and Exit Sign, would IN-20.01 (Push Button to Open Door) and IN-01.07 (Exit Sign) suffice? Are there any additional sign types need for room 100?
| No |
| Room Name |
| Qty |
| Sign Type |
| Sign To Read |
| 100 |
| VESTIBULE |
| 3 OF EACH / 1 OF TYPE A5 |
| TYPE G6 |
| PUSH BUTTON TO OPEN DOORS/A5 TO READ EXIT |
Response: Room 100 to receive (1) sign of each type: G6 and A5. See details below for sign type information:
3. Room 213 and 313 require sign type A2, which is not listed in spec book, please provide sign type detail.
[Source of sign types that are attached is from VA Signage Design Guide 2012]
Response: The sign on specification section 10 14 00 – 12, is Sign type A2.
NOTE: all sign types that are attached are from the VA website, VA Signage Design Guide 2012.
RFI 003 Reference: 102600-Wall Protection
1. Locations of Corner Guards (CG-1) and Wall Protection (WP-1). Both are listed on the Room/Finish Schedule on Drawings RV – Part 5. Nothing is shown/indicated on the Arch. Plans.
Response: Comer Guards are marked on the floor plans. Listed on sheets AE110, AE120 and AE130. They are listed in the legend and on the plans.
List of Attachments
See attached document: Agenda and Sign Sheet.
See attached document: Wage Determination Washtenaw 8-31-2108.
End of Amendment 0001 image1.png image2.png