36C25018B0795-016.pdf
PDF 10 MB Posted
- Attached to
- Construct Clinical and Admin Building 506-329 Federal contract opportunity
- Solicitation number
- 36C25018B0795
About this file
36C25018B0795 506-329 VA Ann Arbor Admin Bldg BID DWGS REVISED_Part6.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25018B0795-0005000.docx | DOCX document | |
| 36C25018B0795-0004000.docx | DOCX document | |
| 36C25018B0795-0003000.docx | DOCX document | |
| 36C25018B0795-0003001.xlsx | XLSX spreadsheet | |
| 36C25018B0795-0002000.docx | DOCX document | |
| 36C25018B0795-0001002.pdf | ||
| 36C25018B0795-0001001.pdf | ||
| 36C25018B0795-0001000.docx | DOCX document | |
| 36C25018B0795-011.pdf | ||
| 36C25018B0795-019.pdf | ||
| 36C25018B0795-017.pdf | ||
| 36C25018B0795-021.pdf | ||
| 36C25018B0795-013.pdf | ||
| 36C25018B0795-009.docx | DOCX document | |
| 36C25018B0795-015.pdf | ||
| 36C25018B0795-018.pdf | ||
| 36C25018B0795-022.docx | DOCX document | |
| 36C25018B0795-014.pdf | ||
| 36C25018B0795-010.pdf | ||
| 36C25018B0795-008.docx | DOCX document | |
| 36C25018B0795-020.pdf | ||
| 36C25018B0795-012.pdf | ||
| 36C25018B0795-007.docx | DOCX document | |
| 36C25018B0795-000.docx | DOCX document |
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLUMBING ABBREVIATIONS
F FAHRENHEIT
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT
(HOSE) CONNECTION
FM FLOW METER
FOP FUEL OIL PUMP
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL VENT
FS FLOOR SINK
FS FLOW SWITCH
FU FIXTURE UNITS
EL ELEVATION
EMCS ENERGY MONOSERRAT
AND CENTRAL SYSTEM
EPA ENVIROMENTAL PROTECTION AGENCY
EPACT ENERGY POLICY ACT
ESC ESCUTCHEON
ESH EMERGENCY SHOWER
ET EXPANSION TANK
EWH ELECTRIC WATER HEATER
EWS EYE WASH STATION
EWS/SH EYE WASH/DRENCH SHOWER
EX EXISTING
DCW DOMESTIC COLD WATER
DFU DRAINAGE FIXTURE UNITS
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DI DEIONIZED WATER
DN DOWN
DOE DEPARTMENT OF ENERGY
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWR DRINKING WATER RETURN
DWS DRINKING WATER SUPPLY
DWV DRAIN WASTE VENT
C CELSIUS
CA COMPRESSED AIR
CGA COMPRESSED GAS ASSOCIATION
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CO CLEANOUT
CS CLINICAL SINK
CV CONTROL VALVE
BFP REDUCED PRESSURE BACKFLOW
PREVENTER
BHP BREAK HORSEPOWER
BSP BLACK STEEL PIPE
BT BATHTUB
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT
PER HOUR
A/E ARCHITECT / ENGINEER
AD AREA DRAIN/ACCESS DOOR
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
AG AIR GAP
AP ACCESS PANEL
AS AUTOMATIC SPRINKLER
ASD ADJUSTABLE SPEED DRIVES
ASD AUTOMATIC SPRINKLER DRAIN
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AIR CONDITIONING
ENGINEERS
ASME AMERICAN SOCIETY OF ECHANICAL
ENGINEERS
ASPE AMERICAN SOCIETY OF PLUMBING
ENGINEERS
ASR AUTOMATIC SPRINKLER RISER
AV ACID VENT
AW ACID WASTE
L/S LITER PER SECOND
LA LABORATORY AIR
LAV LAVATORY
POUNDS PER HOUR
LCW LABORATORY COLD WATER
LHW LABORATORY HOT WATER
LNG LIQUID NATURAL GAS
LOX LIQUID OXYGEN
LV LABORATORY VACUUM
LW LOW WATER
M METER
MAV MANUAL AIR VENT
MBH 1000 BTUH
MED MEDICAL
MER MECHANICAL EQUIPMENT
ROOM
MH MANHOLE
MOU MEMORANDUM OF
UNDERSTADING
MSB MOP SERVICE BASIN
NC NORMALLY CLOSED
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN
N.O.M.A. NOMINAL
NPW NON POTABLE WATER
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OR OPERATING ROOM
OVFL OVERFLOW
KW KILOWATT
KWH KILOWATT-HOUR
ID INSIDE DIAMETER
IE INVERT ELEVATION
ICW INDUSTRIAL COLD WATER
IHW INDUSTRIAL HOT WATER
INV INVERT
IPC INTERNATIONAL PLUMBING CODE
IRW IRRIGATION WATER
IW INDIRECT WASTE
IWH INSTANTANEOUS WATER HEATER
IWR INDUSTRIAL WATER RETURN
IWS INDUSTRIAL WATER SUPPLY
H&CW HOT AND COLD WATER
HB HOSE BIBB
HD HUB DRAIN
HEX HEAT EXCHANGER
HP HORSEPOWER
HS HAND SINK
HST
(DOMESTIC)
HWB HOT WATER BOILER
HWCP HOT WATER CIRCULATING PUMP
HWP HOT WATER PUMP
HYD HYDRANT
GAL GALLON
GCO GRADE CLEANOUTS
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GRS GAS REGULATOR STATION
GT GREASE TRAP
GVTR GAS VENT THROUGH ROOF
GWH GAS FIRED WATER HEATER
PA PASCAL
PD PRESSURE DROP OR
DIFFERENCE
PDI PLUMBING AND DRAINAGE
INSTITUTE
PG PRESSURE GAGE
PP PLUMBING PUMP
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH
ATMOSPHERE
PSIG POUNDS PER SQUARE INCH
GAGE
PTRV PRESSURE TEMPERATURE
RELIEF VALVE
PW POTABLE WATER
ROOF DRAIN
RDL ROOF DRAIN LEADER
RL ROOF LEADER
RP RECIRCULATION PUMP
RO REVERSE OSMOSIS WATER
RWL RAIN WATER LEADER
SAN-P SANITARY SEWER PUMPED
SHEET METAL AND AIR
CONDITIONING CONTRACTORS
NATIONAL ASSOCIATION
SCFM STANDARD CUBIC FOOT/MINUTE
SCW SOFTENED COLD WATER
STORM DRAIN MANHOLE
SMH SANITARY MANHOLE
SP SUMP PUMP
SPR SPRINKLER LINE
SQUARE FEET
SS STAINLESS STEEL
ST STORAGE TANK
SW STORM WATER
TCV TEMPERATURE CONTROL
VALVE
TMD TEMPERATURE DIFFERENCE
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
THERMOSTAT
TWR TEMPERED WATER RETURN
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
V VENT
VAC VACUUM
VB VACUUM BREAKER
VCO VACUUM CLEANER OUTLET
VP VACUUM PUMP
VS VENT STACK
VSD VARIABLE SPEED DRIVE
VTR VENT THROUGH ROOF
W WASTE
WC WATER CLOSET
WCO WALL CLEANOUT
WG WATER GAGE
WH WALL HYDRANT
WH WATER HEATER
WHA WATER HAMMER ARRESTER
WL WATER LINE
WM WATER METER
WPD WATER PRESSURE DROP
WS WASTE STACK
WATER SUPPLY FIXTURE UNITS
YCO YARD CLEANOUT
YH YARD HYDRANT
IPC INTERNATIONAL PLUMBING
CODE
DRAWING SYMBOLS
26-P 3
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
SECTION LETTER
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT IS LOCATED.
PUMP NO.3 IN BUILDING NO.26
EQUIPMENT ABBREVIATION (PUMP)
DRAWING NUMBER WHERE DRAWN
PLUMBING PIPING SYMBOLS
DOMESTIC HOT WATER, HOT WATER
DOMESTIC COLD WATER, COLD WATER
DOMESTIC HOT WATER RETURN, HOT WATER RETURN
STORM WATER, BELOW GRADE
STORM WATER
SANITARY SEWER, BELOW GRADE
DRAIN
DRINKING WATER SUPPLY
DRINKING WATER RETURN
TEMPERED WATER RETURN
TEMPERED WATER SUPPLY
D D
SAN SAN SAN
ST ST ST
ST ST ST
TWR TWR TWR
DWS DWS DWS
DWR DWR DWR
TWS TWS TWS
SOIL, WASTE, OR SANITARY SEWER
SOFTEN COLD WATERSCW SCW SCW
FILTERED COLD WATERFCW FCW FCW
NATURAL GAS, BELOW GRADE
NATURAL GASNG NG NG
VENT (SANITARY)
GENERAL PLUMBING SYMBOLS
LIMIT OF DEMOLITION
ANCHOR
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE CONNECTION
ECCENTRIC REDUCER
BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
UNION
RISE OR DROP IN PIPE
CAPPED OUTLET
AND EXISTING WORK
POINT OF CONNECTION BETWEEN NEW
PRESSURE GAGE
THERMOMETER
STRAINER
FLOW ELEMENT
FLOAT & THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES
PIPING ACCESSORIES
INVERTED BUCKET TRAP SET INCLUDING
FE
PIPE UP
PIPE DOWN
CO CLEAN OUT
HOSE BIB
PLUMBING VALVE SYMBOLS
BALL VALVE
GATE VALVE WITH 3/4 " HOSE ADAPTER
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC FLOW CONTROL VALVE
PRESSURE RELIEF VALVE
GATE VALVE
MANUAL AIR VENT
TEST PLUG (PRESSURE/TEMPERATURE)
GLOBE VALVE
PRESSURE REGULATING VALVE
THREE-WAY TWO POSITION CONTROL VALVE
AUTOMATIC AIR VENT
AV
PL105
A
PL105
HOT WATER STORAGE TANK
LBS/HR
RD
SMACNA
SDMH
SQFT/SF
TSTAT
WSFU
D
NG NG NG
METERM
SAN SAN SAN
SAN SANITARY SEWER
ST-P STORM WATER PUMPED
ORD OVERFLOW ROOF DRAIN
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:4
:3
A
M
PL001
GENERAL NOTES, ABBREVIATIONS,
AND SYMBOLS
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
86 148
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
BIDS SUBMISSION 01-20-17
BIDS SUBMISSION_REVISED 04-12-18
8" STORM
(8250 SF)
1" NG DN FROM GAS
METER SUPPLIED BY
LOCAL UTILITY COMPANY.
1" NG
4" SAN
RISER UP
(91.5 DFU)
8" ST RISER UP
(8270 SF)
4" FCO
4" FD-G
SEE CIVIL DWGS.
FOR CONTINUATION
3" SAN
WETSTACK UP
(4.5 DFU)
STACKED RPBP-1
AND RPBP-2
3" DCW
4" SAN
(139 DFU)
3" DCW
(248 FU)
SEE CIVIL
DWGS. FOR
CONTINUATION
3" DCW RISER UP
4" FD-G
SP-1
SUMP TO HIGHLAND
OIL SEPARATOR
4" SAN
P-501
4" WCO
4" SAN
4" SAN UP
TO COTG
SEE CIVIL
DWGS. FOR
CONTINUATION
3" SAN UP TO 3" WCO,
3" SAN WET STACK UP W/ OFFSETS
(9 DFU) 4" SAN
4" SAN
4" SAN
4" SAN
DROP DOWN
4" SAN UP TO WCO,
3" SANV UP
4" FD-G
4" SAN
3" SAN RISER UP
(7.5 DFU)
8" CO
3" SANV
RISER UP
OS-1
4" FD-M
2" SAN-P
4" SAN
2" SANV UP
4" SAN
3" SAN UP
TO WCO,
1 1/2" SANV
UP
2 1/2" SANV
UP FROM BFF
TP-2
TP-1
3" DCW
4" SAN
MECHANICAL
IT
ELEV. MAC. RM.
STAIRS
S-1
ELEVATOR
E-1
ELECTRICAL
HAC
CORRIDOR
CORRIDOR
CORRIDOR
SPRINKLERS
1/2" TP LINE
1/2" TP LINE
1/2" TP LINE
3" SAN DROP
DN W/ WCO
8" ST
A B C D
HE
4.2
J
2.8
4.8
G
5.4
F K
M
3/4" NG
750 CFH
TO B-01
750 CFH
TO B-02
3/4" NG PRV-1
METER
1/2" DCW/DHW UP
1" NG
PRV-2
RPBP-3
1/2" DHW
1/2" DCW
4" SAN
3" SAN
3" SAN
3" SAN
3" SAN UP
(1.5 DFU)
4" SAN UP
(1.5 DFU)
3" SAN UP
(3 DFU)
3" SAN UP
(1.5 DFU)
I. E. 813' - 5"
I. E. 813' - 2"
I. E. 814' - 3"
1" DCW
1" DCW
3" ST-P
3" ST-P
3" ST-P
4" FD-G
4" FCO
SP-2
1'-0"
REFER TO STRUCTURAL DWGS.
FOR DRAIN TILE CONNECTION.
FINAL CONNECTION BY
PLUMBING CONTRACTOR.
I. E. 810' - 0"
8" ST
REPLACE EXISTING PIPE
WITH PVC SCH80
4" SAN
4" SAN
I. E. 798' - 0"
3" SANV 3" SANV
3" SANV
ADVANCED NATURAL
GAS METER
1" NG
2" SANV RISER UP
ADVANCED
WATER METER
NOTE:
ADVANCED METERS TO COMPLY WITH
SPECIFICATIONS SECTION 251010
3" SAN
4" ST
4" ST
4" FCO
2 1/2" SANV
2" SANV
1-AHU1
B-02B-01
2" SANV
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:4
:4
A
M
Scale: 3/16" = 1'-0"
PL100
PLUMBING BASEMENT PLAN
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
87 148
N
SCALE: 3/16" = 1'-0"
BASEMENT FLOOR PLUMBING PLAN
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
P-531
NEW GAS METER INSTALLED BY
LOCAL UTILITY PIPING STANDARD.
CONTRACTOR TO PROVIDE 2 PSI
OUTLET PRESSURE
1500 CFH
75 FT RUN
P-106
P-531
P-531
8" OFD TO 8" DS-1
(8250 SF)
8" OFD RISER UP
8" ST RISER UP AND DN
8" OFD DROP DN
P-801
1" NG DOWN
P-801
P-801
P-801
3" SAN DN
PL200
PL200
3" WETSTACK DN
2" SANV UP
2" SANV
1/2" DCW
3" WCO
8" OFD
8" OFD
1/2" DCW
HAC
IT
ELECTRICAL
P.I.V.
P.I.V
STAIRS
S-1
ELEVATOR
E-1
STAIRS
S-2
MEN'S TOILET
VESTIBULE
OPEN OFFICE
ELEVATOR LOBBY
HR BENEFIT RA/FMLA
CORRIDOR
OPEN OFFICE
VESTIBULE
WAITING
RECORDS STORAGE
HR SPECIALIST OFFICER
HR BENEFITS
SPECIALIST
HR PROCESS
PHYS / PROV
EXAM
EXAM
TLT
TREATMENT AREA
OPEN OFFICE
HR SPECIALIST OFFICER
CORRIDOR
ASSIST HR CHIEF
OFFICER
HR CHIEF OFFICER
CORRIDOR
OWC
COFFEE
HR PROCESS BENEFITS
HR RECRUITMENT
WOMEN'S TOILET
HR SPECIALIST OFFICER
WAITING
P-531
P-531
1 1/2" SAN UP
3/4" DCW
1/2" DHW
3/4" DHWR
3/4" DHW
3/4" DCW
3" SAN UP
W/ OFFSET
1/2" DHW
1/2" DCW
1" DCW
3/4" DHW
3" WCO
3/4" DCW
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DCW DROP DN
1/2" DCW DROP DN
1/2" DCW
DROP DN
1/2" DCW DROP DN
1/2" DCW
1 1/2" SANV
A B C D
HE
4.2
J
2.8
4.8
G
5.4
F K
1/2" DCW
1/2" DCW
2" SANV
1 1/2" SAN
3" WCO
3/4" DHWR
2" SANV RISER
1/2" DHW
1/2" DCW
1 1/2" SANV
1 1/2" SANV
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:4
:5
A
M
Scale: 3/16" = 1'-0"
PL110
PLUMBING FIRST FLOOR PLAN
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
88 148
N
SCALE: 3/16" = 1'-0"
FIRST FLOOR PLUMBING PLAN
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
P-422
P-101
P-531
2" WETSTACK
UP AND DN
3" SAN UP TO 2" SANV
1 1/2" SAN
2" SANV UP
2" SANV
3/4" DHW
1 1/4" DCW
8" ORD RISER UP AND DN
8" RD RISER UP AND DN
MEN'S TOILET
219 HAC
IT
217 ELECTRICAL
ASSISTANT CHIEF
230 CHIEF
UNISEX RR
OPEN OFFICE
AFO
CFO
INTERNAL AUDITOR
STAIRS
S-1
ELEVATOR
E-1
STAIRS
S-2
VESTIBULE
CORRIDOR
OPEN OFFICE
OPEN OFFICE
CORRIDOR
ACCOUNTING
SUPERVISOR
OPEN OFFICE
ELEVATOR LOBBY
BREAK ROOM
CONFERENCE ROOM
WOMEN'S TOILET
PAYROLL SUPERVISOR
MCA PROGRAM OFFICE
COFFEE
PL200
PL200
1 1/4" DCW
1/2" DHW
1/2" DCW
1/2" DHW
1" DCW
1 1/2" SANV
A B C D
HE
4.2
J
2.8
4.8
G
5.4
F K
3/4" DHWR
1" DCW
WHA
3/4" DHWR
3/4" DHW
2" SANV RISER
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:4
:0
A
M
Scale: 3/16" = 1'-0"
PL120
PLUMBING SECOND FLOOR PLAN
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
89 148
N
SCALE: 3/16" = 1'-0"
SECOND FLOOR PLUMBING PLAN
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
6" OFD UP TO
4" OD-1 (3530 SF)
6" ST UP TO
4" RD-1 (3530 SF)
2" SANV DN TO 2"
WETSTACK W/ CO
6" OFD UP TO 4" OD-1
(4720 SF)
6" ST UP TO 4" RD-1
(4720 SF)
6" OFD
2" SANV UP
TO 3" VTR
8" OFD RISER DN
8" ST RISER DN
6" ST
6" ST
6" OFD
6" CO (2)
ASST CHIEF MAS OFF
NON-VA CARE SUPV
VESTIBULE
MEN'S TOILET
HAC
IT
ELECTRICAL
HBU SUPRVISOR
CHIEF MAS OFFICER
SCANNING SUPV
RECORD MANAGER
OFFICER
MED RECORDS
SUPERVISOR
STAIRS
S-1
ELEVATOR
E-1
STAIRS
S-2
OPEN OFFICE
OPEN OFFICE
CORRIDOR
OPEN OFFICE
CONF. ROOM
ELEVATOR LOBBY
OPEN OFFICE
CORRIDOR
WOMEN'S TOILET
CODING SUPERVISOR
OFFICE
ADMINISTRATIVE
OFFICER
COFFEE
PL200
PL200
2" SANV
1/2" DHW
1/2" DCW
A B C D
HE
4.2
J
2.8
4.8
G
5.4
F K
2" SANV RISER
UP TO 3" VTR
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:4
:0
A
M
Scale: 3/16" = 1'-0"
PL130
PLUMBING THIRD FLOOR PLAN
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
90 148
N
SCALE: 3/16" = 1'-0"
THIRD FLOOR PLUMBING PLAN
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
P-101P-101
P-101
P-101
P-202
P-422
P-604
P-101
P-422
4" WCO
3" FD-C3" FD-C
4" SAN RISER
P-422
P-422
3" SANV RISER
2" SANV HEADER
4" SAN HEADER
1 1/2" SANV
2" SAN HEADER
1 1/2" SANV
2" SAN HEADER
P-502
3" WETSTACK
WOMEN'S TOILET
MEN'S TOILET
HAC
VESTIBULE
D
3" FD-C
3" DCW RISER UP AND DN
1/2" TP LINE
P-101P-101
P-101
P-101
P-202
P-422
P-604
P-101
P-422
P-422
P-422
TP-2
1" DCW
3/4" DHWR
2 1/2" DCW
3/4" DHW
3/4" DCW
1/2" DHW
1/2" DCW
3/4" DHWR
3/4" DHW
2" DCW
2" DCW
1" DCW
3/4" DHW
3/4" DHWR
3/4" DHW/ DHW
DOWN TO P-504
ON BASEMENT
LEVEL
P-502
1/2" DCW/DHW DROP DN
DWHR-1
HET-1
WOMEN'S TOILET
VESTIBULE
MEN'S TOILET
HAC
1/2" DCW
1/2" DHW
1/2" DCW
D
WH-1
WHA
1 1/2" DCW
1 1/4" DCW
1 1/4" DCW
WHA
3/4" DHW
1/2" DCW
1/2" DHW
TP-2
1/2" TP LINE
P-101P-101
P-101
P-101
P-202
P-422
P-604
P-101
P-422
4" WCO
3" FD-C3" FD-C
4" SAN RISER
P-422
P-422
3" SANV RISER
2" SANV HEADER
4" SAN HEADER
1 1/2" SANV
2" SAN HEADER
1 1/2" SANV
2" SAN HEADER
P-502
3" WETSTACK
WOMEN'S TOILET
MEN'S TOILET
HAC
VESTIBULE
2" SAN 2" SAN
D
3" FD-C
3" DCW RISER UP AND DN
1/2" TP LINE
P-101P-101
P-101
P-101
P-202
P-422
P-604
P-101
P-422
P-422
P-422
TP-2
1" DCW
2 1/2" DCW
1/2" DHW
3/4" DCW
1/2" DCW
1/2" DHW
1/2" DHW
1/2" DCW
3/4" DHWR
3/4" DHW
2" DCW
2" DCW
1 1/4" DCW
3/4" DHW
3/4" DHWR
P-502
1/2" DCW/DHW DROP DN
WOMEN'S TOILET
VESTIBULE
MEN'S TOILET
HAC
1/2" DHW
1/2" DCW
D
WH-2
HET-2
DHWR-2
WHA
WHA
1 1/4" DCW
1 1/2" DCW
1 1/4" DCW
3/4" DHW
3/4" DHWR
TP-2
1/2" TP LINE
P-101P-101
P-101
P-101
P-202
P-422
P-604
P-101
P-422
4" WCO
3" FD-C3" FD-C
3" SANV DN TO 4" SAN RISER
P-422
P-422
3" SANV RISER DN
1 1/2" SANV HEADER
1 1/2" SANV HEADER
P-502
2" SANV DN TO
3" WETSTACK
WOMEN'S TOILET
MEN'S TOILET
HAC
VESTIBULE
4" SANV UP
TO 4" VTR
2" SANV
3" SANV HEADER
4" SAN HEADER
2" SAN 2" SAN
2 1/2" SANV
4" SANV
3" WCO
D
3" FD-C
3" DCW RISER DN
1/2" TP LINE
P-101P-101
P-101
P-101
P-202
P-422
P-604
P-101
P-422
P-422
P-422
TP-2
2 1/2" DCW
3/4" DHW
3/4" DCW
1/2" DCW
1/2" DHW
1/2" DHW
2" DCW
P-502
1/2" DCW AND DHW DROP DN
WOMEN'S TOILET
VESTIBULE
MEN'S TOILET
HAC
1/2" DHW
1/2" DCW
2" DCW
3/4" DCW
3/4" DHW
2" DCW
1/2" DCW UP TO P-808
ON ROOF. TAKE ROOF
HYDRANT DRAIN LINE
TO SPILL INTO
NEAREST MOP SINK
D
1/2" DCW
WH-3
3/4" DCW
3/4" DHW
HET-3
WHA
WHA
1 1/4" DCW
1 1/2" DCW
1 1/4" DCW
TP-2
1/2" TP LINE
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:5
:4
A
M
Scale: 3/8" = 1'-0"
PL200
PLUMBING PIPING PARTIAL PLANS
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
91 148
SCALE: 3/8" = 1'-0"PL110
1 ENLARGED TOILET CORE FIRST FLOOR PLUMBING PLAN - WASTE
SCALE: 3/8" = 1'-0"PL110
2 ENLARGED TOILET CORE FIRST FLOOR PLUMBING PLAN - WATER
SCALE: 3/8" = 1'-0"PL120
3 ENLARGED TOILET CORE SECOND FLOOR PLUMBING PLAN - WASTE
SCALE: 3/8" = 1'-0"PL120
4 ENLARGED TOILET CORE SECOND FLOOR PLUMBING PLAN - WATER
SCALE: 3/8" = 1'-0"PL130
5 ENLARGED TOILET CORE THIRD FLOOR PLUMBING PLAN - WASTE
SCALE: 3/8" = 1'-0"PL130
6 ENLARGED TOILET CORE THIRD FLOOR PLUMBING PLAN - WATER
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
P-502
P-502
P-422
P-422
P-422
P-422
P-604
P-101
P-202
P-101
P-101
P-101
P-101
4" FD-C
4" FD-C
WCO
P-422
P-422
P-422
P-422 P-604
P-101
P-202 P-101
P-101
P-101
P-101
4" FD-C
4" FD-C
WCO
P-422
P-422
P-422
P-422 P-604
P-101
P-202
P-101
P-101
P-101
P-101
4" FD-C
4" FD-C
WCO
4" VTR
4" SAN
3" SANV
4" SAN
3" SAN
3" SAN
3" SAN
2 1/2" SANV
2 1/2" SANV
3" SANV
4" SANV
4" SANV
2" SANV
3" SANV
3" SANV
3" SANV
3" SANV
2" SAN
2" SAN
2" SAN
2" SANV
2" SANV
2" SANV
2" SANV
2" SAN
2" SANV
2" SAN
2" SAN
CO
WCO
3" SANV, SEE DWG.
2/PL300 FOR CONT.
4" SAN
SEE DWG. 2/PL300
FOR CONT.
2" SANV
2" SAN
2" SAN
P-531
P-531
WCO
P-531
3" SANV SEE
DWG. 2/PL300 FOR CONT.
2" SAN
2" SANV
2" SANV
2" SAN
2" SAN
1 1/2" SANV
1 1/2" SANV
1 1/2" SANV
1 1/2" SANV
1 1/2" SANV
1 1/2" SANV
1 1/2" SANV
2" SAN
2" SAN
2" SAN
2" SAN
2" SANV
2" SANV
2" SANV
2" SANV
4" SAN
3" SAN
3" SAN
4" SAN
3" SAN
3" SAN
4" SAN
3" SAN
3" SAN
3" SANV
3" SANV
4" FD-C
4" FD-C
4" FD-C
3" SAN
3" SAN
3" SAN
3" SAN, SEE DWG.
2/PL300 FOR CONT.
4" SAN
SEE DWG. 3/PL300
FOR CONT.
WCO
P-501
4" SAN
SEE DWG. 1/PL300
FOR CONT.
SEE DWG.
1/PL300
FOR CONT.
WCO
3" SAN
SEE DWG. 1/PL300
FOR CONT.
4" SAN
4" SAN
4" SAN
4" SAN
3" SAN
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN
2" SANV
2" SAN-P
2" SAN-P
4" SAN
4" FCO
WCO
FD-G
FD-G
FD-G
4" FCO
SP-1
OS-1
FD-M
3" SAN
4" SAN
WCO
4" SAN
4" SAN
3" SAN
3" SAN
4" SAN
3" SAN
2 1/2" SANV
3" SANV
3" SANV
3" SANV
3" SANV
2" SANV UP TO 3" VTR
3" SANV
SEE DWG.
1/PL300
FOR CONT.
2" SANV
P-531
P-531
P-101 P-422
P-531
P-531
P-106
P-531
WCO
WCO
3" VTR
4" SAN
SEE DWG. PL100
FOR CONT.
4" SAN
4" SAN
4" SAN
3" SAN
3" SAN
1 1/2" SANV
1 1/2" SANV
1 1/2" SANV
3" SAN
4" SAN
3" SAN
3" SAN
3" SAN
2" SANV
2" SANV
1 1/2" SANV
1 1/2" SANV
2" SANV
2" SANV
1 1/2" SANV
3" SAN
1 1/2" SANV
1 1/2" SAN
1 1/2" SANV
1 1/2" SAN
3" SAN
2" SANV
2" SANV
2" SANV
4" SAN
SEE DWG. 2/PL300
FOR CONT.
WCO
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:5
:4
A
M
Scale:
PL300
PLUMBING PIPING RISER DIAGRAMS
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
92 148
SCALE: NOT TO SCALE
1 WASTE AND VENT ISOMETRIC - TOILET CORE
SCALE: NOT TO SCALE
2 WASTE AND VENT ISOMETRIC - BASEMENT
SCALE: NOT TO SCALE
3 WASTE AND VENT ISOMETRIC - FIRST AND SECOND FLOOR
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
P-502
P-422
P-422
P-422 P-422
P-604
P-101
P-202
P-101
P-101
P-101P-101
TP-2
P-422
P-422
P-422 P-422
P-604
P-101
P-202
P-101
P-101
P-101P-101
P-422 P-422
P-422
P-422 P-604
P-101
P-202
P-101
P-101
P-101P-101
TP-2
TP-2
1/2" TP LINE
1/2" TP LINE
1/2" TP LINE
SEE DWG.
2/PL301 FOR
CONT.
P-808
P-531
P-531
P-531
SEE DWG. 3/PL301
FOR CONT.
SEE DWG. 4/PL301
FOR CONT.
WH-3
WH-2
WH-1
HET-3
HET-2
HET-1
DHWR-2
DHWR-1
1/2" DCW
1/2" DHW
1/2" DCW
2 1/2" DCW
3/4" DHW
3/4" DCW
3/4" DHW
3/4" DCW
1/2" DCW
1/2" DHW
3/4" DHW
3/4" DHW
3/4" DCW
1/2" DCW
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DHW
3/4" DHW
1" DCW
3/4" DHWR
1/2" DHW
1/2" DCW
3/4" DHW
3/4" DCW
1/2" DCW
2 1/2" DCW
1/2" DHW
3/4" DCW 2" DCW
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DHW
3/4" DHW
2" DCW
2 1/2" DCW
3/4" DHW
3/4" DCW
1/2" DHW
1/2" DCW
3/4" DHWR
3/4" DHW
1" DCW
1/2" DCW
SEE DWG. PL110
FOR CONT.
3/4" DHW
3/4" DCW
1/2" DHW
1/2" DCW
1/2" DCW
1/2" DHW
3" DCW
3" DCW
2" DCW
2 1/2" DCW
3/4" DCW
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DHW
3" DCW
1 1/2" DCW
1 1/4" DCW
1 1/2" DCW
1 1/2" DCW
2" DCW
1/2" DCW
1/2" DHW
3" DCW
1/2" DHW
1/2" DCW
2" DCW
3/4" DHW
3/4" DHWR
2" DCW
1 1/4" DCW 1 1/2" DCW
WHA
WHA
WHA
WHA
WHA
WHA
1 1/4" DCW
1 1/4" DCW
3/4" DHWR
TP-2
TP-2
TP-2
1/2" TP LINE
1/2" TP LINE
1/2" TP LINE
1/2" DCW
P-801
P-801
P-531
P-531
P-531
P-531
P-106
SEE DWG 1/PL301
FOR CONT.
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DHW
1/2" DCW
1" DCW
3/4" DHW
3/4" DCW
1/2" DHW
3/4" DHWR
3/4" DHW
3/4" DCW
3/4" DCW
1/2" DCW
3/4" DHWR
SEE DWG 1/PL301
FOR CONT.
P-101
P-422
P-531
1 1/4" DCW
1/2" DHW
1/2" DCW
1/2" DHW
WHA
1" DCW
1/2" DCW
1/2" DHW
3/4" DHWR
3/4" DHW
1 1/4" DCW
3/4" DHW
3/4" DHWR
RPBP-3
PRV-2
DOWN
TO B-01
DOWN
TO B-02
SEE DWG. 1/PL301
FOR CONT.
1" DCW
1" DCW
1" DCW
3" DCW
3" DCW
1/2" DCW
3" DCW
3" DCW
P-501
TP-1
TP-1
RPBP-1
RPBP-2
PRV-1
ADVANCED WATER METER
3" DCW
1/2" TP LINE
1/2" TP LINE
SEE CIVIL
DWGS FOR CONT.
1/2" DCW
WATER METER
BY UTILITY
COMPANY
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:5
:5
A
M
Scale:
PL301
PLUMBING PIPING RISER DIAGRAMS
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
93 148
SCALE: NOT TO SCALE
1 SUPPLY PIPING RISER DIAGRAM - TOILET CORE
SCALE: NOT TO SCALE
3 SUPPLY PIPING RISER DIAGRAM - FIRST FLOOR
SCALE: NOT TO SCALE
4 SUPPLY PIPING RISER DIAGRAM - SECOND FLOOR
SCALE: NOT TO SCALE
2 SUPPLY PIPING DIAGRAM - BASEMENT
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
B-01
B-02
1" NG UP TO NEW GAS METER INSTALLED BY
LOCAL UTILITY PIPING STANDARD. 2 PSI
OUTLET PRESSURE,1500 CFH, 75 FT RUN
1" NG
3/4" NG
3/4" NG
1" NG
ADVANCED NATURAL GAS METER
1" NG
DS-1
(8250 SF)
RD-1
(3530 SF)
ORD-1
(3530 SF)
RD-1
(4720 SF)
ORD-1
(4720 SF)
CO
CO
6" ST
6" OFD
6" OFD
6" ST
6" ST
6" OFD
8" ST
8" OFD
8" OFD
8" OFD
8" ST
8" ST
(8250 SF)
SEE CIVIL DWGS.
FOR CONTINUTAION
3" ST-P
SP-2
FCO
FCO
3" ST-P
3" ST-P
3" ST-P
FD-G 4" ST
4" ST
4" ST
REFER TO STRUCTURAL DWGS. FOR
DRAIN TILE CONNECTION. FINAL
CONNECTION BY PLUMBING CONTRACTOR.
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:5
:5
A
M
Scale:
PL302
PLUMBING PIPING RISER DIAGRAMS
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
94 148
SCALE: NOT TO SCALE
1 NATURAL GAS DIAGRAM
SCALE: NOT TO SCALE
2 STORM WATER DIAGRAM
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
EXTERIOR SIDE OF CONCRETE WALL
1/4" [6mm] STEEL PLATE WATER
STOP & ANCHOR COLLAR
[5 m m
FLEXIBLE EXPANSION JOINT
MIN. DEFLECTION 15" [375mm] MIN. EXPANSION 4" [100mm]
RESILIENT WATERPROOF
CAULKING
5/8" [16mm] ROD
WELD
PIPE CENTERED
IN SLEEVE
1/4"x1/4" [6x6mm] IRON
PIPE CLAMP
STANDARD WEIGHT GAL.
STEEL PIPE SLEEVE
1/4"x1/4" [6x6mm] IRON
PIPE STRAP
MODULAR TYPE WALL
PENETRATION SEAL
FLANGED
CONNECTION
[1 m m
INTERIOR SIDE
OF WALL
STAINLESS STEEL BOLTS,
NUTS & WASHERS
NICKLE BRONZE ADJUSTABLE
STRAINER (FLUSH WITH
FINISHED FLOOR)
CEMENT BED
TILE FLOOR
CONCRETE FILL
STRUCTURAL SLAB
FLASHING
CLAMP WITH
WEEP HOLES
THREADED, CAULKED
OR
NO-HUB CONNECTION
LOOSE GRAVEL
AT WEEP HOLES
3mm to 6mm SIZE
WATERPROOF MEMBRANE
PROVIDE A METAL
SUPPORT PLATE WHEN
DRAIN IS INSTALLED IN
AN EXISTING FLOOR -
CAULK AROUND DRAIN
PRIOR TO RE-GROUTING
CLAMP WATERPROOF
MEMBRANE INSIDE OF DRAIN
BODY TO DRAIN TO WEEP
HOLES
NOTE:
SLOPE MEMBRANE LINER 2% TO DRAIN.
FLASHING MEMBRANE, MIN. 24" [600mm] SQUARE 2 1/2 LB. [1.1kg] TO 4 LB. [1.8kg] LEAD OR 16 OZ. [0.45kg] COPPER.
ADJUSTABLE NICKEL
BRONZE STRAINER WITH 4"
[100mm] FLANGE (FLUSH
WITH FINISHED FLOOR)
WEEP HOLES
COMPOSITION FLOORING
NOTE:
1. SLOPE MEMBRANE LINER 2% TO DRAIN.
2. PROVIDE FLASHING MEMBRANE WHEN DRAIN IS INSTALLED IN A NON MEMBRANE
FLOOR
INVERTIBLE
FLASHING COLLAR
LOOSE GRAVEL
AT WEEP HOLES
3mm TO 6mm
GRAVEL SIZE
CAULKED, NO-HUB
OR THREADED
CONNECTION
WIDE FLANGE
[3 m m
WALL LINE
REDUCED PRESSURE PRINCIPLE
BACKFLOW PREVENTER WITH
GATE VALVES
PLAN
AIR GAP
FITTING
PIPE TO DRAIN
(TYPICAL)
FINISHED FLOOR
COLD WATER TO
SYSTEM
PIPE SUPPORT
ELEVATION
[3 m m
T O
B O
T T
O M
O F
R E
L
IE
F O
P E
N
IN
G S
M
IN
COLD WATER
FROM METERS
9" [225mm] DIA.
TWO-PIECE NICKEL BRONZE
FLASHING STRAINER (FLUSH
WITH FINISHED FLOOR)
FLASHING
PAN
SEAMLESS VINYL FLOORING
FLASHING MEMBRANE, MIN. 24" [600mm] SQUARE 2 1/2 LB. [1.1kg] TO 4 LB.
[1.8kg] LEAD OR 16 OZ. [453g] COPPER
CAULKED, NO-HUB
OR THREADED
CONNECTION
FLASHING COLLAR
WITH WEEP HOLES
LOOSE GRAVEL AT
WEEP HOLES
PROVIDE A METAL SUPPORT PLATE
WHEN DRAIN IS INSTALLED IN AN
EXISTING FLOOR- CAULK AROUND
DRAIN PRIOR TO RE-GROUTING
NOTES:
1. SLOPE MEMBRANE LINER 2% TO DRAIN.
2. PROVIDE FLASHING MEMBRANE WHEN DRAIN IS INSTALLED IN A NON-MEMBRANE FLOOR.
8" DEEP FLOOR
SINK WITH
FUNNEL
2" SUMP PUMP
DISCHARGE FROM
ELEVATOR PIT
2" VENT
OIL LEVEL CONTROL PANEL
FLOOR
4" SAN
OIL INTERCEPTOR
4"
EQUIPMENT
N
GGAS SHUTOFF
VALVE
SEE FLOOR PLAN
FOR PIPE SIZE
LINE SIZE
6" LONG DIRT LEG
UNION 2" AND SMALLER
FLANGE 2 1/2" AND LARGER
GAS REGULATOR
(BY EQUIPMENT SUPPLIER)
INSTALLED BY PLUMBER.
2 PSI
5 FT
THRU [20]
6 8 10
[32][25] [40]
[65]
[50]
[75]
-1312 14 -16 -
[125][100]
[150]
[250]
[200]
[300]
[400]
[350]
[450]
[600]
[500]
20 241814 16128 1064 532 2 1/21 1/21 1 1/4
[9100] [9600][8500][7600] [8200][7000][5800] [6700][5200][4100] [4900][3700][3000] [3400][2700][2100]
--- --[4900] -[4100][3700] [4000] -[3000][2400][1800][1500]
THRU 3/4
[2100] [2100]
[2100]
[2700]
[2400]
SIDE VIEW TRAPEZE HANGER FOR UP
TO 1000 LB. [453KG] UNIFORM LOAD
ADJUSTABLE CLEVIS HANGER
TYPE 1 - SEE SPECIFICATIONS
ADJUSTABLE CLEVIS HANGER
TYPE 43 - SEE SPECIFICATIONS
MAXIMUM PIPE/TUBING SUPPORT SPACING
NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.
NOM. SIZE
PIPE
TUBING
IN.
[mm]
FT.
[mm]
FT.
[mm]
[2 m m
M A
X
PROVIDE INSULATION SHIELD
& INSERT FOR ALL PIPING
(8" [200mm] MIN.)
BAND
1-5/8" [43mm] 12 GAUGE CHANNEL OR 2"x2"x1/4" [50x50x6.4mm] ANGLE
1/2" [15mm] DIA.
HANGER RODS WITH
36" [900mm] MAX.
SPACING ON EACH
CHANNEL
WELD
SADDLE
INSULATION SHIELD
AT HANGER
PROVIDE HIGH
COMPRESSIVE STRENGTH
INSULATION (9 PSF MIN.
DENSITY) UNDER
INSULATION SHIELD
INSULATION (VAPOR
BARRIER TYPE IS
REQUIRED FOR LOW
TEMPERATURE PIPE)
HANGER ROD
NOTES:
SEE SPECIFER FOR DETAILED
HANGER REQUIREMENTS
VACUUM RELIEF
VALVE OR DIP TUBE
CONNECTION
EXPANSION TANK
COLD WATER TO
HEATER
CHECK VALVE
(TYPICAL)
A.S.M.E TEMPERATURE AND
PRESSURE RELIEF VALVE
PIPE FULL SIZE TO FLOOR
DRAIN
HEAT TRAP MIMIMUM
OF 27"
GALVANIZED NIPPLE
(TYPICAL)
BALL VALVE
(TYPICAL)
TO HOT WATER SYSTEM
DHW140º F
THERMOMETER
HEAT TRAP MIMIMUM
OF 27"
DRAIN VALVE, PIPE CONNECTION
SIZE TO FLOOR DRAIN
SAFETY PAN WITH
DRAIN TO FLOOR DRAIN
FINISHED FLOOR LINE
WH-3
VACUUM RELIEF
VALVE OR DIP TUBE
CONNECTION
EXPANSION TANK
COLD WATER TO
HEATER
THERMOMETER
HOT WATER
RETURN
RECIRCULATION
PUMP
A.S.M.E TEMPERATURE AND
PRESSURE RELIEF VALVE
PIPE FULL SIZE TO FLOOR
DRAIN
DRAIN VALVE, PIPE CONNECTION
SIZE TO FLOOR DRAIN
SAFETY PAN WITH
DRAIN TO FLOOR DRAIN
FINISHED FLOOR LINE
GALVANIZED NIPPLE
(TYPICAL)
BALL VALVE
(TYPICAL)
TO HOT WATER SYSTEM
DHW 140º F
THERMOMETER
CHECK VALVE (TYPICAL)
WH-1 & WH-2
3" SCH80
PVC DISCHARGE
36"
TANK
I.D. 20 1/2"
10"
5 5/16" 3 15/16"
12"
48"
1 1/4" SCH80 PVC
PIPE AND PIPE
FITTINGS
JB70
ELECTRICAL
ENCLOSURE
42"
42" DIA.
FIBERGLASS
COVER SHOWN
4" SCH80
PVC INLET
13"
25"
31"
4" SCH80
PVC INLET
30"
CONCRETE BALLEST
FOR HOLD DOWN (TYP.)
FAUCET SEE SPECIFICATIONS
OFFSET
WASTE
TRAP PARALLEL
TO WALL
LOOSE KEY
STOP
ESCUTCHEON
" 8"
/4
F O
R F
IX
T
U R
E H
E
IG
H T
S S
E E
A R
C H
IT
E
C T
U R
A L
D R
A W
IN
G
S
NOTES:
1. CABINET MOUNTED HAND SINKS PLUMBED SIMILAR
FINISHED FLOOR
TMV
HOT WATER
THERMOSTATIC MIXING
VALVE SET TO
DISCHARGE 110°F
WATER
LINE
BYPASS
WATER
METER
FLOOR
ELEVATION
SUPPORT BRACKET
ANCHORED TO
WALL OR COLUMN
80 MESH
STRAINER
N.C.
3'-6" [1.1M]
WATER METER PROVIDED BY
LOCAL UTILITY COMPANY
SUPPORT BRACKET
ANCHORED TO
WALL OR COLUMN
PRV-1
DCW TO BACKFLOW
PREVENTER
NG
BYPASS
NATURAL GAS
METER
FLOOR
ELEVATION
SUPPORT BRACKET
ANCHORED TO
WALL OR COLUMN
N.C.
3'-6" [1.1M]
NG TO SYSTEM
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:5
:5
A
M
Scale: As indicated
PL400
PLUMBING DETAILS
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
95 148
SCALE: NOT TO SCALE
6 PIPE PENETRATION THROUGH WALLS BELOW GRADE
SCALE: NOT TO SCALE
9 TYPE "C" FLOOR DRAIN DETAIL
SCALE: NOT TO SCALE
11 TYPE "D" FLOOR DRAIN DETAIL
SCALE: NOT TO SCALE
2 BACKFLOW PREVENTER PIPING DETAIL
SCALE: NOT TO SCALE
10 TYPE "F" FLOOR DRAIN DETAIL
SCALE: NOT TO SCALE
5 ELEVATOR SUMP PUMP OIL INTERCEPTOR
SCALE: NOT TO SCALE
NATURAL GAS EQUIPMENT
PIPING CONNECTION
SCALE: NOT TO SCALE
3 PIPE HANGERS
SCALE: NOT TO SCALE
13 ELECTRIC WATER HEATER DETAIL W/ HEAT TRAP
SCALE: NOT TO SCALE
12 ELECTRIC WATER HEATER DETAIL W/ PUMP
SCALE: NOT TO SCALE
4 DUPLEX SUMP PUMP DETAIL
SCALE: NOT TO SCALE
7 TYPICAL SINK AND LAVATORY DETAIL
SCALE: NOT TO SCALE
1 WATER METER INSTALLATION
SCALE: NOT TO SCALE
14 NATURAL GAS METER INSTALLATION
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
1050 Wilshire Drive, Suite 260 Troy, MI 48084 T 248-643-6222
SSOE, Inc.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
M
S
S O
E .r v t
/9
/2
:5
:0
A
M
Scale:
PL500
PLUMBING SCHEDULES
HENSON
506-329CLINICAL & ADMINISTRATIVE
BUILDING
SCHAFF01-20-17
96 148
DHWP-2 HAC - 218 SECOND FLOOR DHWR RECIRC
DOMESTIC HOT
WATER
2 [ 12 ] 10 [ 30 ] NA NA 140 [ 60 ] 0.16 [ ] 1 120 1725 CONSTANT ----
DHWP-1 HAC - 119 FIRST FLOOR DHWR RECIRC
DOMESTIC HOT
WATER
2 [ 12 ] 10 [ 30 ] NA NA 140 [ 60 ] 0.16 [ ] 1 120 1725 CONSTANT ----
SP-2 SPRINKLERS - 007 BASEMENT SAN-P SUMP STORM DRAINAGE 66 [ 4 ] 25 [ 400 ] NA NA 140 [ 60 ] 0.75 [ 1 ] 1 208 3500 VARIABLE
DUPLEX PUMP SYSTEM, 36 W" X 48
H" BASIN.
SP-1 ELEVATOR - E1 ELEVATOR SAN-P SUMP HYDRAULIC FLUID 50 [ 3 ] 25 [ 400 ] NA NA 140 [ 60 ] 1 70 0.5 [ ] 1 115 3500 CONSTANT 3/4 SOLIDS.
GPM [L/s] FT [kPa] FT [kPa] °F [°C] HP [kW]
FLUID
FLOW HEAD NPSH AVAILABLE TEMPERATURE
SP. GR.
MIN. %
EFF
NOMINAL
POWER
PHASE VOLT
MAX
RPM
SPEED
CONTROL
REMARKS
MARK LOCATION AREA AND/OR BLDG SERVED
SYSTEM
AND/OR
SERVICE
TYPE
CIRCULATING FLUID ELECTRICAL MOTOR
PLUMBING PUMP SCHEDULE
WH-3 HAC - 318 THIRD FLOOR
DOMESTIC HOT
WATER
ELECTRIC 30 [ 110 ] 19 [ 72 ] 60 100 [ 690 ] 2 5000 2500 3 208
3/4" INLETS/ OUTLETS; INCLUDE
TEMPERATURE RELIEF VALVES TO
LIMIT DISCHARGE TO 130º F
WH-2 HAC - 218 SECOND FLOOR
DOMESTIC HOT
WATER
ELECTRIC 50 [ 190 ] 25 [ 95 ] 60 100 [ 690 ] 2 6000 3000 3 208
3/4" INLETS/ OUTLETS; INCLUDE
TEMPERATURE RELIEF VALVES TO
LIMIT DISCHARGE TO 130º F
WH-1 HAC - 119
BASEMENT AND
FIRST FLOOR
DOMESTIC HOT
WATER
ELECTRIC 50 [ 190 ] 25 [ 95 ] 60 100 [ 690 ] 2 6000 3000 3 208
3/4" INLETS/ OUTLETS; INCLUDE
TEMPERATURE RELIEF VALVES TO
LIMIT DISCHARGE TO 130º F
GAL [L] GAL/HR [L/HR] PSIG [kPa] TOTAL kW kW PER
ELEMENT
PHASE VOLT
MARK LOCATION
AREA AND/OR
BLDG SERVED
SYSTEM AND/OR
SERVICE
TYPE
STORAGE CAPACITY
RECOVERY @ 70 °F
[21°C] RISE TIME TO RECOVER
CONTENTS, MINUTES
RELIEF VALVE SETTING
NO OF
ELEMENTS
ELECTIRCAL INPUT
REMARKS
ELECTRIC WATER HEATER SCHEDULE
HET-3 HAC - 318
POTABLE THERMAL
EXPANSION TANK
60 [ 16 ] 140 [ 60 ] 50 [ 350 ] 80 [ 550 ] 100 [ 690 ] 15 [ 57 ] 10.5 [ 40 ] .75 [ 19 ] -----
HET-2 HAC - 218
POTABLE THERMAL
EXPANSION TANK
60 [ 16 ] 140 [ 60 ] 50 [ 350 ] 80 [ 550 ] 100 [ 690 ] 15 [ 57 ] 10.5 [ 40 ] .75 [ 19 ] -----
HET-1 HAC - 119
POTABLE THERMAL
EXPANSION TANK
60 [ 16 ] 140 [ 60 ] 50 [ 350 ] 80 [ 550 ] 100 [ 690 ] 15 [ 57 ] 10.5 [ 40 ] .75 [ 19 ] -----
°F [°C] °F [°C] PSIG [kPa] PSIG [kPa] PSIG [kPa] GAL [L] GAL [L] IN [mm]
MIN MAXMARK LOCATION TYPE
SYSTEM TEMPERATURE RANGE
INITIAL PRESSURE IN
TANK
MAX OPERATING
PRESSURE
RELIEF VALVE PSIG [kPA] MIN TANK VOLUME MIN ACCEPT VOLUME PIPE SIZE TO TANK
REMARKS
EXPANSION TANK SCHEDULE
WHA-1 WATER HAMMER ARRESTOR - [ - ] - [ - ] - [ - ] - [ - ] - - N/A NO SIZE TO MANUFACTURER'S REQUIREMENTS
COTG CLEAN OUT TO GRADE - [ - ] - [ - ] - [ - ] - [ - ] - - N/A NO
FCO FLOOR CLEAN OUT - [ - ] - [ - ] - [ - ] - [ - ] - - N/A NO
FD-M FLOOR DRAIN 4 [ 100 ] 3 [ 75 ] - [ - ] - [ - ] 2 - N/A NO OIL INTERCEPTOR
FD-G FLOOR DRAIN 4 [ 100 ] 2 [ 50 ] - [ - ] - [ - ] 2 - N/A NO MECHANICAL ROOMS
FD-C FLOOR DRAIN 3 [ 75 ] 2 [ 50 ] - [ - ] - [ - ] 2 - N/A NO RESTROOMS
P-808
NON-FREEZE ROOF
HYDRANT
1.5 [ 38 ] - [ - ] .75 [ 19 ] - [ - ] - 3 N/A NO
TP-2 TRAP PRIMER - [ - ] - [ - ] .5 [ 13 ] - [ - ] - - N/A NO RESTROOMS
TP-1 TRAP PRIMER - [ - ] - [ - ] .5 [ 13 ] - [ - ] - - N/A NO MECHANICAL ROOMS
OS-1 OIL SEPARATOR 3 [ 75 ] 2 [ 50 ] - [ - ] - [ - ] - - N/A NO 2" INLET/ 3" WASTE OUTLET
P-801 WALL HYDRANT - [ - ] - [ - ] .5 [ 13 ] - [ - ] - 3 N/A NO
P-604 ELECTRIC WATER COOLER 1.5 [ 38 ] 1.5 [ 38 ] .375 [ 9 ] - [ - ] .5 0.25 N/A NO PROVIDE WITH BOTTLE FILLER
P-531
STAINLESS STEEL SINK
SINGLE BOWL
1.5 [ 38 ] 1.5 [ 38 ] .375 [ 9 ] .375 [ 9 ] 3 2 N/A NO WITH WRIST BLADE HANDLES
P-502
SERVICE SINK FLOOR MTD
CORNER
3 [ 75 ] 1.5 [ 38 ] .5 [ 13 ] .5 [ 13 ] 2 4 N/A NO
P-501 SERVICE SINK FLOOR MTD 3 [ 75 ] 1.5 [ 38 ] .5 [ 13 ] .5 [ 13 ] 2 4 N/A NO
P-422 LAVATORY 1.5 [ 38 ] 1.5 [ 38 ] .375 [ 9 ] .375 [ 9 ] 1 2 N/A YES FAUCET AND DRAINS, SOLID SURFACE
P-202 URINAL WALL HUNG 2 [ 50 ] 1.5 [ 38 ] .75 [ 19 ] - [ - ] 2 3 N/A YES
P-106
WATER CLOSET TAN, FLOOR
MTD
3 [ 75 ] 2 [ 50 ] .375 [ 9 ] - [ - ] 4 5 N/A YES FLUSH TANK WITH LOCKING TANK
P-101 WATER CLOSET FLOOR MTD 3 [ 75 ] 2 [ 50 ] 1 [ 25 ] - [ - ] 4 10 N/A YES
IN [mm] IN [mm] IN [mm] IN [mm]
MARK DESCRIPTION
WASTE PIPE VENT PIPE COLD WATER HOT WATER WASTE
FIXTURE
UNITS
WATER
FIXTURE
UNITS
WRIST
BLADE
HANDLES
ELECTRIC
SENSOR
REMARKS
PLUMBING FIXTURE SCHEDULE
PRV-2 MECHANICAL - 011 BOILERS MECH NPW PRESSURE REDUCING VALVE [ ] 38 [ 260 ] 1 [ 25 ] 23 [ 160 ] 1 [ 25 ]
COORDINATE WITH BOILER MANUFACTURER
FOR WATER MAKE UP PRESSURE REQUIRED
FOR BOILERS.
PRV-1 SPRINKLERS - 007 ADMIN DCW PRESSURE REDUCING VALVE [ ] 67 [ 460 ] 3 [ 75 ] 52 [ 360 ] 3 [ 75 ] SET PRV TO A MINIMUM OF 52 PSI
RPBP-3 MECHANICAL - 011 BOILERS MECH NPW
REDUCED PRESSURE
BACKFLOW PREVENTER
[ ] 50 [ 350 ] 1 [ 25 ] 38 [ 260 ] 1 [ 25 ] -----
RPBP-2 SPRINKLERS - 007 ADMIN DCW
REDUCED PRESSURE
BACKFLOW PREVENTER
[ ] 82 [ 570 ] 3 [ 75 ] 67 [ 460 ] 3 [ 75 ] -----
RPBP-1 SPRINKLERS - 007 ADMIN DCW
REDUCED PRESSURE
BACKFLOW PREVENTER
[ ] 82 [ 570 ] 3 [ 75 ] 67 [ 460 ] 3 [ 75 ] -----
CU FT/HR [L/HR] PSIG [kPa] IN [mm] PSIG [kPa] IN [mm]
MARK LOCATION
AREA AND/OR
BLDG SERVED
SYSTEM AND/OR
SERVICE
TYPE
CAPACITY INLET PRESSURE INLET SIZE OUTLET PRESSURE OUTLET SIZE
REMARKS
PLUMBING SPECIALTIES
B-02
HOT WATER
HEATING BOILER
1.25 [31] 750,000 NA 14 WC NA
B-01
HOT WATER
HEATING BOILER
1.25 [31] 750,000 NA 14 WC NA ----
IN [mm] BTUH [W] PSIG [kPa]
MARK DESCRIPTION
NAT GAS PIPE SIZE NAT GAS DEMAND GAS PRESSURE
REMARKS
GAS DEMAND SCHEDULE
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
LC
M
FEEDWATER SAMPLE (FROM DEAERATOR)
BOILER WATER SAMPLE
CONTINUOUS BLOWDOWN
CHEMICAL FEED
BOILER BLOWOFF
TUBE CLEANER WATER SUPPLY
COMPRESSED AIR
OVERFLOW
COLD WATER (CITY WATER)
LIQUEFIED PETROLEUM GAS IGNITER FUEL
NATURAL GAS IGNITER FUEL
NATURAL GAS MAIN FUEL
HOT WATER
SOFTENED WATER
FUEL OIL RETURN
FUEL OIL SUPPLY
RH
SCH
SH
TH
PS
RC
RISER CLAMP (TYPE 42)*
FLOOR-SUPPORTED PIPE STAND
CLEVIS-TYPE HANGER
VARIABLE SPRING-TYPE HANGER (TYPE 51)*
ROLLER-TYPE HANGER
TO TRAPEZE EXCEPT WHERE RH ARE INDICATED)
TRAPEZE HANGER (PROVIDE U-BOLT PIPE ATTACHMENT
SPRING CUSHION-TYPE HANGER (TYPE 48 OR 49)*
WB
CSH
SS
STANDARD PRACTICE SP-58
SLIDING SUPPORTS (TYPE 35)*
CONSTANT SUPPORT HANGER (TYPE 54, 55, 56)*
WALL BRACKET (TYPE 31, 32, 33)*
* TYPE NUMBERS REFER TO MANUFACTURER'S STANDARDIZATION SOCIETY
QUICK-COUPLE HOSE CONNECTOR
GATE VALVE WITH GLOBE-VALVED BYPASS
PLUG VALVE
CONTROL VALVE (CV) - FLOAT-OPERATED
PRESSURE REDUCING VALVE (PRV)
HOSE CONNECTOR
WYE STRAINER WITH VALVED DRAIN AND QUICK-COUPLE
WATER LEVEL CONTROLLER
FLOW METER
NOTE:
1.
2.
3.
4.
5.
RIGID STRAIGHT TERMINAL UNIT INLET LENGTH SHALL BE A
MINIMUM OF 3 TIMES THE DIAMETER OF INLET
A FLEXIBLE AIR DUCT CONNECTOR IS NOT MANDATORY FOR INLET TO THIS BOX, BUT
ALLOWED TO ACCOMMODATE MINOR OFFSETS. MAXIMUM LENGTH 3'-0" [900mm].
A BRANCH DUCT SERVING AN INDIVIDUAL BOX MAY BE THE SAME SIZE AS THE BOX
INLET, PROVIDED THE EQUIVALENT LENGTH OF THE BRANCH DUCT, AS SHOWN, DOES
NOT EXCEED 10 FEET (3 METERS). FOR LONGER LENGTHS, INCREASE THE DUCT SIZE
AND PROVIDE A DUCT TRANSITION TO MAINTAIN THE DUCT STATIC PRESSURE DROP AT
OR BELOW 0.2"/100' [1.64Pa/m].
FLEXIBLE AIR DUCT CONNECTORS, WHEN USED FROM TERMINAL UNIT SUPPLY AIR DUCT
TO DIFFUSER, SHALL NOT EXCEED 5'-0" [1500mm]. USE RIGID ELBOWS FOR CHANGE
OF DIRECTION GREATER THAN 45°.
COMPONENT ARRANGEMENT MAY VARY BY MANUFACTURER. PROVIDE
INSULATION W/VAPOR BARRIER FOR CONNECTING DUCT SECTIONS.
ABBREVIATION AND SYMBOL NOTES
1. THE COMPOSITE LIST OF ABBREVIATIONS IS COORDINATED WITH THE UNITED STATES
NATIONAL CAD STANDARD VERSION 4.0, LEGACY VA LIST OF ABBREVIATIONS, AND ASHRAE.
THIS LIST SHALL BE USED FOR ALL VA PROJECTS AND EDITED, AS REQUIRED, TO BE
PROJECT SPECIFIC. THE DESIGNER MAY SELECT AND USE ADDITIONAL ABBREVIATIONS, IF
REQUIRED, FROM ANY KNOWN SOURCES.
2. THE LIST OF SYMBOLS IS MOSTLY BASED ON THE VA MASTER LIST OF STANDARD
SYMBOLS AND HAS BEEN UPDATED IN CONSULTATION WITH OTHER SOURCES, SUCH AS,
NATIONAL CAD STANDARD VERSION 4, AND ISA (THE INSTRUMENTATION, SYSTEMS, AND
AUTOMATION SOCIETY). THIS LIST SHALL BE USED FOR ALL VA PROJECTS AND EDITED,
AS REQUIRED, TO BE PROJECT SPECIFIC. THE DESIGNER CAN SELECT AND USE
ADDITIONAL SYMBOLS, IF REQUIRED, FROM ANY KNOWN SOURCE
GENERAL NOTES
ABBREVIATIONS
D DAMPER - AUTOMATIC
D-1 OUTDOOR AIR DAMPER
D-2 RETURN AIR DAMPER
D-3 RELIEF AIR DAMPER
DB DECIBELS
Db DRY-BULB TEMPERATURE
DD-1 DESIGN DEVELOPMENT
(SUBMISSION1)
DD-2 DESIGN DEVELOPMENT
(SUBMISSION2)
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DF DIFFUSER
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
DP DIFFUSER PLATE
DPA DIFFERENTIAL PRESSURE ASSEMBLY
DPS DIFFERENTIAL PRESSURE SENSOR
DX DIRECT EXPANSION
DXCC DIRECT EXPANSION COOLING COIL
CD-2 CONSTRUCTION DOCUMENTS
(SUBMISSION2)
CENT CENTRIFICAL
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFT CUBIC FEET
CFP CHEMICAL FEED PUMP
CG CEILING GRILLE
CH CHILLER
CHP CHILLED WATER PUMP
CHW CHILLER WATER
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CI CAST IRON
CM CARBON MONOXIDE
CM CUBIC METER
CM/S CUBIC METER PER SECOND
CO CLEAN OUT
CO2 CARBON DIOXODE
COMP COMPRESSOR UNIT
COP COEFFICIENT OF PERFORMANCE
CP CONDENSATE PUMP
CR CEILING REGISTER
CS CONDENSATE STORAGE TANK
CSG CLEAN STEAM GENERATOR
CT COOLING TOWER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CWCC CHILLED WATER COOLING COIL
CWP CONDENSER WATER PUMP
CWR CONDENSER WATER RETURN (TO
COOLING TOWER)
CWS CONDENSER WATER SUPPLY
(FROM COOLING TOWER)
B BOILER
BD BUTTERFLY DAMPER
BDD BACKDRAFT DAMPER
BDR BASE BOARD RADIATOR
BFP BACKFLOW PREVENTER
BFT BOILER PLANT FIRE TUBE
BG BOTTOM GRILLE
BHP BRAKE HORSEPOWER
BHW HOT WATER HEATING BOILER
BHX BOILER BLOWDOWN HEAT EXCHANGER
BIW BACKWARD INCLINED WHEEL (FAN)
BMT BONE MARROW TRANSPLANT
BR BOTTOM REGISTER
BSC BIOLOGICAL SAFETY CABINETS
BT BLOWOFF TANK
BTC BLOWOFF TANK CONTROL VALVE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
BWT BOILER PLANT WATER TUBE
A/E ARCHITECT / ENGINEER
AAHX AIR TO AIR HEAT EXCHANGER
AB AIR BLENDER
AAV AUTOMATIC AIR VENT
ACC AIR COOLED CONDENSER
ACCH AIR COOLED CHILLER
ACCU AIR-COOLED CONDENSING UNIT
ACU AIR CONDITIONING UNIT
ACD AUTOMATIC CONTROL
DAMPER,MODULATING
ACD-TP AUTOMATIC CONTROL
DAMPER,TWO POSITION
AD ACCESS DOOR
AF AFTER FILTER
AFCV AIR FLOW CONTROL VALVE
AFF ABOVE FINISHED FLOOR
AFMD AIR FLOW MEASURING DEVICE
AFW AIR FOIL WHEEL (FAN)
AHU AIR-HANDLING UNIT
AMP AMPERGE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARI AIR CONDITIONING AND
REFRIGERATION INSTITUTE
AS AIR SEPARATOR
ASME AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
AW AIR WASHER
AXF AXIAL FLOW
C CENTIGRADE (CELCIUS)
CC COOLING COIL
CCD COOLING COIL CONDENSATE
DRAIN
CD CEILING DIFFUSER
CD-1 CONSTRUCTION DOCUMENTS
(SUBMISSION1)
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC EVAPORATIVE COOLER
ECC ENGINEERING CONTROL CENTER
ECU EVAPORATIVE CONDENSER UNIT
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EG EXHAUST GRILLE
EGS EMERGENCY GAS SHUTOFF
EGT ENTERING GLYCOL TEMPERATURE
EH EXHAUST HOOD
EJ EXPANSION JOINT
EMD END OF MAIN DRIP (STEAM)
ENT ENTERING
ER EXHAUST REGISTER
ERC ELECTRIC REHEAT COIL
ERP ELECTRIC RADIANT PANEL
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
ETO ETHYLENE OXIDE
EUH ELECTRIC UNIT HEATER
EWC EVAPORATIVE WATER COOLER
EWT ENTERING WATER TEMPERATURE
E.X. EXISTING
F FAHRENHEIT
F&T FLOAT AND THERMOSTATIC
F/SDPR COMBINATION FIRE SMOKE
DAMPER
FA FREE AREA
FC FLEXIBLE CONNECTION
FCU FAN COIL UNIT (4 PIPE)
FCUC FAN COIL UNIT COOLING ONLY
FCUH FAN COIL UNIT HEATING ONLY
FCW FORWARD CURVED WHEEL (FAN)
FD FLOOR DRAIN
FD FIRE DAMPER
FF FINAL FILTER
FHX FLUE GAS/FEEDWATER HEAT
EXCHANGER
FM FLOW METER
FOP FUEL OIL PUMP
FOT FUEL OIL TANK
GA GAUGE
GAL GALLONS
GH GRAVITY HOOD
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GS GALVANIZED STEEL
H HUMIDIFER
H&CW HOT & COLD WATER
HAC HOUSEKEEPING AID CLOSET
HB HOSE BIBB
HC HEATING COIL
HD HEAD
HD HOOD
HOA HAND/OFF/AUTOMATIC
HP HEAT PUMP
HP HORSEPOWER
HPDT HIGH PRESSURE DRIP TRAP
HPR HIGH PRESSURE RETURN
(STEAM CONDENSATE)
HPS HIGH PRESSURE SUPPLY
(STEAM)
HRC HEAT RECOVERY COIL
HRD HEAT RECOVERY DEVICE
HRP HYDRONIC RADIANT (CEILING)
PANEL
HRW HEAT RECOVERY WHEEL
HSTAT HUMIDISTAT
HTM HUMIDIFIER TERMINAL
HUM HUMIDIFIER UNIT MOUNTED
HVU HEATING AND VENTILATING UNIT
HW HOT WATER
HWC HOT WATER COIL
HWHC HOT WATER HEATING COIL
HWP HEATING HOT WATER PUMP
HWR HEATING HOT WATER RETURN
HWS HEATING HOT WATER SUPPLY
HWUH HOT WATER UNIT HEATER
HVD HOISTWAY VENT DAMPER
HX HEAT EXCHANGER
HZ HERTZ
FT FEET
FT-LB FOOT-POUND
FTR FIN TUBE RADIATION
FV FACE VELOCITY
OA OUTSIDE AIR
OAG OUTSIDE AIR GRILLE
OAI OUTSIDE AIR INTAKE
OD OUTSIDE DIAMETER
OFM OIL FLOWMETER
OR OPERATING ROOM
NA NOT APPLICABLE
NC NOISE CRITERIA
NC NORMALLY CLOSED
NG NATURAL GAS
NGFM NATURAL GAS FLOWMETER
NO NORMALLY OPEN
NOAA NATIONAL OCEANIC & ATMOSPHERIC ADMINISTRATION
NOM NOMINAL
NPLV NON-STANDARD PART LOAD VALUE
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
M METER, SI UNIT
M/s METERS PER SECOND
(OR METERS/SECOND)
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAU MAKE-UP AIR UNIT
MAV MANUAL AIR VENT
MAX MAXIMUM
MB MIXING BOX
MBH 1000 BTUH
MCA MINIMUM BRANCH CIRCUIT AMPACITY
MER MECHANICAL EQUIPMENT ROOM
MERV MINIMUM EFFICIENCY REPORTING
VALUE
MH MANHOLE
MHP MOTOR HORSEPOWER
MIN MINIMUM
MM MILLIMETER
MOV MOTOR OPERATED VALVE
MPR MEDIUM PRESSURE RETURN
(STEAM CONDENSATE)
MPS MEDIUM PRESSURE STEAM
MRI MAGNETIC RESONANCE IMAGING
MTD MEAN TEMPERATURE DIFFERENCE
MVD MANUAL VOLUME DAMPER
MZ MULTI-ZONE
L LITER
L/h LITERS PER HOUR (OR LITERS/HOUR) L/m LITERS PER MINUTE (OR LITERS/MINUTE) L/s LITERS PER SECOND (OR LITERS/SECOND)
LAT LEAVING AIR TEMPERATURE
LBS/HR POUNDS PER HOUR
LF LINEAR FOOT (FEET)
LGT LEAVING GLYCOL TEMPERATURE
LH LATENT HEAT
LPG LIQUID PROPANE GAS
LPR LOW PRESSURE RETURN (STEAM CONDENSATE)
LPRC LOW PRESSURE STEAM RETURN (CLEAN)
LLHX LIQUID TO LIQUID HEAT EXCHANGER
LPS LOW PRESSURE STEAM
LPSC LOW PRESSURE STEAM (CLEAN)
LSD LINEAR SLOT DIFFUSER
LTCP LOCAL TEMPERATURE CONTROL PANEL
LVG LEAVING
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
kg KILOGRAM kg/HR KILOGRAM PER HOUR kPa KILOPASCAL kW KILOWATT kWh KILOWATT HOUR
J INTENTIALLY LEFT BLANK
I/O INPUT/OUTPUT
IAQ INDOOR AIR QUALITY
IBT INVERTED BUCKET TRAP
ICF IN-LINE CENTRIFUGAL FAN
ICU INTENSIVE CARE UNIT
ID INSIDE DIAMETER
IFB INTEGRAL FACE AND BYPASS
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
IN-LB INCH-POUND
IPLV INTERGRATED PART LOAD VALUE
IRH INTRARED HEATER
IS INSECT SCREEN
IU INDUCTION UNIT
IV INLET VANES
T&PCV TEMPERATURE AND PRESSURE
CONTROL VALVE
TAB TESTING, ADJUSTING, BALANCE
TD TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TDS TOTAL DISSOLVED SOLIDS
TG TRANSFER GRILLE
TP TRAP
TR TOP REGISTER
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TU TERMINAL UNIT
TWU THRU-WALL UNIT
SA SUPPLY AIR
SAD SOUND ATTENUATING DEVICE
SAT SUPPLY AIR TEMPERATURE
SC SHADING COEFFICIENT
SCFM STANDARD CUBIC FEET PER MINUTE
SCI SPINAL CODE INJURY
SCR SILICON CONTROLLED RECTIFIER
SD SMOKE DETECTOR
SD SUPPLY AIR DIFFUSER
SD-1 SCHEMATIC DESIGN (SUBMISSION1)
SD-2 SCHEMATIC DESIGN (SUBMISSION2)
SDPR SMOKE DAMPER
SDR SMOKE DAMPER (RETURN)
SDS SMOKE DAMPER (SUPPLY)
SEN SENSIBLE HEAT
SF SUPPLY FAN
SG SUPPLY AIR GRILLE
SH STEAM HUMIDIFIER
SHC STEAM HEATING COIL
SI SQUARE INCHES
SP STATIC PRESSURE
SP GR SPECIFIC GRAVITY
SPD SUPPLY PROCESS AND DISTRIBUTION
SPRV STEAM PRESSURE REDUCING VALVE
SPS STATIC PRESSURE SENSOR
SQ FT SQUARE FOOT (FEET)
SR SUPPLY AIR REGISTER
SS STAINLESS STEEL
SSHX STEAM TO STEAM HEAT EXCHANGER
SSR SOLID SEPARATOR
ST STEAM TRAP
SUH STEAM UNIT HEATER
SV STEAM PRESSURE REDUCING VALVE
SVS STEAM VENT SILENCER
SWHX STEAM TO WATER HEAT EXCHANGER
R/E RETURN OR EXHAUST
RA RETURN AIR
RAD REFRIGERANT AIR DRYER
RAF RADIO FREQUENCY
RAHX ROTARY AIR HEAT EXCHANGER
RAT RETURN AIR TEMPERATURE
RCCH REMOTE CONDENSER CHILLER
RCU RECIPROCATING CHILLER UNIT
RD REFRIGERANT DISCHARGE
RDS ROOM DATA SHEETS
REA RELIEF AIR
RF RETURN FAN
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID LINE
RLA RUN LOAD AMPERE
RO REVERSE OSMOSIS
RPM REVOLUTIONS PER MINUTE
RR RETURN REGISTER
RS REFRIGERANT SUCTION
RTU ROOF TOP UNIT
RV RELIEF VALVE
P PUMP
PA PASCAL
PC PUMPED CONDENSATE
PCF POUNDS PER CUBIC FOOT (FEET)
PD PRESSURE DROP
PEF PROPELLER (TYPE) EXHAUST FAN
PF PRE-FILTER
PG PRESSURE GAGE
PGW PROPYLENE GLYCOL-WATER (SOLUTION)
PHC PREHEAT COIL
PPM PARTS PER MILLION
YR YEAR
W WATTS
WAG WASTE ANETHESIA GAS
Wb WET-BULB (TEMPERATURE)
WC WATER COOLED
WCCH WATER COOLED CHILLER
WCCU WATER COOLED CONDENSING UNIT
WCHP WATER COOLED HEAT PUMPS
WCPU WATER COOLED PACKAGED UNIT
WEF WALL EXHAUST FAN
WF WATER FILTER
WFCV WATER FLOW CONTROL VALVE
WFM WATER FLOWMETER
WFMD WATER FLOW MEASURING DEVICE
WG WATER GAGE
WPD WATER SIDE PRESSURE DROP
V VALVE
VAF VANE-AXIAL FAN
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL OPPOSED…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.