36C25018B0795-012.pdf
PDF 9 MB Posted
- Attached to
- Construct Clinical and Admin Building 506-329 Federal contract opportunity
- Solicitation number
- 36C25018B0795
About this file
36C25018B0795 506-329 VA Ann Arbor Admin Bldg BID DWGS REVISED_Part2.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25018B0795-0005000.docx | DOCX document | |
| 36C25018B0795-0004000.docx | DOCX document | |
| 36C25018B0795-0003001.xlsx | XLSX spreadsheet | |
| 36C25018B0795-0003000.docx | DOCX document | |
| 36C25018B0795-0002000.docx | DOCX document | |
| 36C25018B0795-0001001.pdf | ||
| 36C25018B0795-0001002.pdf | ||
| 36C25018B0795-0001000.docx | DOCX document | |
| 36C25018B0795-015.pdf | ||
| 36C25018B0795-018.pdf | ||
| 36C25018B0795-022.docx | DOCX document | |
| 36C25018B0795-014.pdf | ||
| 36C25018B0795-011.pdf | ||
| 36C25018B0795-019.pdf | ||
| 36C25018B0795-017.pdf | ||
| 36C25018B0795-021.pdf | ||
| 36C25018B0795-013.pdf | ||
| 36C25018B0795-009.docx | DOCX document | |
| 36C25018B0795-010.pdf | ||
| 36C25018B0795-008.docx | DOCX document | |
| 36C25018B0795-020.pdf | ||
| 36C25018B0795-007.docx | DOCX document | |
| 36C25018B0795-016.pdf | ||
| 36C25018B0795-000.docx | DOCX document |
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3'-5"
1'-8" 1'-9"
2'-6"
1'-6" 1'-0"
6" 1'-0"
1'-0"
1'-0" 1'-0"
1'-0" 1'-4"
.0
H
1'-6" 1'-0"
1'-8" 1'-9"
2"
1'-6"
20#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
PIER P-1
PIER P-2 PIER P-3 PIER P-4
PIER P-5
PIER P-6
PIER P-12
20#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
T/WALL = 816'-0"
T/WALL = 816'-0"
T/PIER REFER TO PLAN
T/WALL = 816'-0"
T/PIER REFER TO PLAN
T/WALL = 816'-0"
T/PIER REFER
TO PLAN
T/WALL = 816'-0"
T/WALL = 816'-0"
32#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
2" TYP
28#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
A
A
T/WALL = 816'-0"
T/WALL = 816'-0"
2" TYP
T/WALL = 816'-0"
T/WALL = 816'-0"
T/PIER REFER TO PLAN
14#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
2" TYP
T/WALL = 816'-0"
T/PIER REFER
TO PLAN
14#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
2'-6"
1'-0" 1'-6"
16#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
PIER P-14
T/WALL = 816'-0"
T/WALL = 816'-0"
T/PIER REFER
TO PLAN
B
14#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
PIER P-15
T/WALL = 816'-0" T/WALL = 816'-0"
T/PIER REFER
TO PLAN
D
1'-0" 1'-0"2'-6"
1'-0"1'-6"
16#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
PIER P-13
T/WALL = 816'-0"
T/WALL = 816'-0"
T/PIER REFER
TO PLAN
2" TYP
2" TYP
1'-5 3/4"
"4
22#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
PIER P-9
T/WALL &
PIER = 815'-4"
T/WALL = 815'-7"
T/PIER REFER
TO PLAN
E
2" TYP
3'-3"2'-8"
44#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
PIER P-8
T/WALL &
PIER = 815'-7"
T/WALL = 815'-4"
T/PIER REFER
TO PLAN
D
2" TYP 7
1'-0" 1'-0"
12#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
2" TYP
PIER P-7
D E
C
1'-6"
2"
2" TYP
16#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
T/PIER REFER
TO PLAN
T/WALL =
816'-0"
T/WALL =
816'-0"
1'-8" 1'-4"
2.8
J
PIER P-10
1'-4" 1'-8"
4"
30#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
T/PIER REFER
TO PLAN
T/WALL =
816'-0"
T/WALL =
816'-0"
3'-0"
J
4.2
1'-8"
1'-4" 1'-6"
5'-9".
1'-0"
/2
F
1'-6"
1'-2" 4"
9'-11"
4" 1'-0"
4.8
K
.0
1'-8 1/4".
7"
6 1/4"
1'-2" 1'-2"
2'-3" 1'-2"
20#7 VERT W/
#4 TIES @ 12" OC
(4) TIES @ 3" OC
TOP
30#7 VERT W/#4 TIES @ 12" OC(4) TIES @ 3" OCTOP
T/PIER 815'-4"
T/ WALL=815'-7"
T/WALL=816'-0"
T/WALL=801'-0"
2'-0"x2'-0"x2'-0" DEEPSUMP PIT T/WALL=816'-0"
#5@12" OC HORIZ EF#7@10" OC VERT EF
#5@12" OC HORIZ EF
#7@10" OC VERT EF
#4@12" OCHORIZ EF
#4@8" OC
VERT EF W/STD HK
SC301
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:5
P
M
Scale: 1/2" = 1'-0"
SC302
PIER DETAILS
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
17 148
SCALE: 1/2" = 1'-0"SC100
A ENLARGED ELEVATOR PIT PLAN
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
BIDS SUBMISSION 01-20-17
BIDS SUBMISSION_REVISED 04-12-18
VERT REINF
T/FTG EL
REFER TO PLAN
T/PEDESTAL EL
REFER TO PLAN
TYPICAL INTERIOR FOOTING
WITH PEDESTAL-PLAN
TYPICAL INTERIOR FOOTING
WITH PEDESTAL-SECTION
L
L
STRUC
COLUMN
DOWELS TO
MATCH VERT
REINF
TIES
ANCHOR BOLTS
FINISH FLOOR EL.
REFER TO PLAN
STRUC
STEEL COL.
C COL,FTG, & PEDESTAL UNO
C C
O L F
T G
P E
D E
S T
A L U
N O
SCALE 3/4"=1'-0" SCALE 3/4"=1'-0"SEE SCHEDULE FOR DIMENSIONAL
AND REINFORCEMENT REQUIREMENTS.
SEE TYPICAL INTERIOR FOOTING
SECTION W/ PEDESTAL.
SEE SCHEDULE FOR DIMENSIONAL
AND REINFORCEMENT REQUIREMENTS.
b
EQ EQ
W
EQ EQ
E Q
E Q d
E Q
E Q
D
G R
O U
T
M A
X
REFER TO PLAN & SCHEDULE
EQ EQ
V A
R
IE
S
R E
F E
R T
O P
L A
N
S C
H E
D U
L E
SCALE:
TYPICAL ISOLATION JOINT DETAIL
SCALE:
TYPICAL GRADEWALL REINF AT PENETRATION
SCALE:
TYPICAL SLAB ON GRADE DETAILS
SCALE:
TYPICAL EQUIPMENT PAD SECTION
SCALE:
TYPICAL EQUIPMENT PAD W/ TRENCH SECTION
SECTION
PLAN - AT INTERIOR COLUMNS
PLAN - AT EXTERIOR COLUMNS
NOTES:
3. USE FOR EQUIPMENT WITH WATER CONNECTIONS.
NOTES:
2 ADD'L #4 BARS LENGTH =
PENETRATION DIA. + 2'-0,
BEND AS REQ'D AT TOP AND
BOTT OF GRADEWALL (TYP
4 PLACES)
4. SECURE HOOKED BARS INTO EXISTING CONCRETE W/ CONCRETE
ANCHOR ADHESIVE.
TYPICAL SLAB CONTROL JOINT (CJ)
TYPICAL SLAB CONSTRUCTION JOINT (CJ)
2. COORDINATE SIZE WITH EQUIPMENT SUPPLIER AND APPROPRIATE CONTRACTOR. 2. COORDINATE SIZE WITH EQUIPMENT SUPPLIER AND APPROPRIATE CONTRACTOR.
1. COORDINATE PAD LOCATIONS W/ ELECTRICAL AND/OR MECHANICAL DRAWINGS1. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR PAD LOCATIONS.
COL.
PEDESTAL
FIN. FLR.
PEDESTAL BELOW
(OR BASE PLATE
AT LOCATIONS
WITHOUT PEDESTAL)
CONTROL JOINT OR
CONSTRUCTION JOINT
CONTROL JOINT OR
CONSTRUCTION JOINT
PEDESTAL BELOW
(OR BASE PLATE
AT LOCATIONS
WITHOUT PEDESTAL)
6x6-W2.9xW2.9 WWF
FIN FLOOR
EQUIP
6x6-W2.9xW2.9 WWF
FIN FLOOR
EQUIP
GRADEWALL
GRADEWALL PENETRATION
GRADEWALL
ADD 2#5 BARS
ACROSS OPNG
FIN FLOOR
REFER TO PLAN
REINF (REFER TO PLAN)
REINF (REFER TO PLAN)
SAWED JOINT
W/JOINT FILLER
OUTER LIMITS OF EQUIP
DRILL & EPOXY ANCHOR
#3 HOOKED BAR W/MIN
3" EMBED AROUND EXTERIOR
OF PAD SPACED 18" OC
(MIN 3 PER SIDE)
DRILL & EPOXY ANCHOR
#3 HOOKED BAR W/MIN 3" EMBED
AROUND EXTERIOR OF PAD SPACED
18" OC (MIN 3 PER SIDE)
1'-0"± 1'-0"±
UTILITIES UNDER GRADEWALL,
SEE UTILITY DWGS (TYP)
APPLY BONDING COMPOUND
AND ROUGHEN SLAB TO 1/4"
MIN AMPLITUDE
4" WIDE x 2" DEEP TRENCH w/ OUTLET
TO FLOOR DRAIN
WHERE SHOWN ON
PIPING DWGS
EPOXY TOPPING
& FINISH 3/4"x45 DEG CHAMFER
APPLY BONDING COMPOUND
AND ROUGHEN SLAB TO
1/4" MIN AMPLITUDE
3/4"x45 DEG CHAMFER
1/2" EXP JT MATL W/ JT SEALER
VAPOR BARRIER @
1ST FLOOR SLAB
ON GRADE ONLY
6" COMPACTED GRANULAR
SUB-BASE
6" COMPACTED GRANULAR
SUB-BASE
TOOLED JOINT
WITH JOINT FILLER
1/2" EXP JT MATL W/ JT SEALER
1/2" EXP JT MATL
W/ JT SEALER
NONE
NONE NONESCALE:
GRADEWALL ELEV AT UTILITIES
NONE
3/4"=1'-03/4"=1'-0
3/4"Ø PLAIN DOWEL
x 18" LONG @ 12" OC
GREASE ONE END
1/8".
" 1
/2
R E
F E
R T
O P
L A
N
9". 9".
E Q
E Q
R E
F E
R T
O P
L A
N
2".
2" TYP
W & L
3" TYP
S L A
B R
E F
E R
T O
P L A
N
W & L
4"± OUTER LIMITS OF EQUIP 4"±
S L A
B R
E F
E R
T O
P L A
N
3. HARD TROWEL FINISH.
5. HARD TROWEL FINISH.
COMPACTED SUBGRADE
VAPOR BARRIER @
1ST FLOOR SLAB
ON GRADE ONLY
COMPACTED SUBGRADECONTRACTOR SHALL SUBMIT
PROPOSED CONSTRUCTION JOINT
LAYOUT FOR ENGINEERED REVIEW
PRIOR TO CONSTRUCTION
T/FOOTING EL
REFER TO PLAN
TYPICAL INTERIOR FOOTING
W/O PEDESTAL SECTION
ANCHOR BOLTS
FINISH FLOOR EL.
REFER TO PLAN
STRUC
STEEL COL.
SCALE 3/4"=1'-0" SEE SCHEDULE FOR DIMENSIONAL
AND REINFORCEMENT REQUIREMENTS.
REFER TO PLAN & SCHEDULE
EQ EQ
R E
F E
R T
O P
L A
N
S C
H E
D U
L E
G R
O U
T
TYP
2'-0"
TYP
2'-0"
6"
6"
6"
6"
WALL CORNER
PIER (SEE PLAN)
WALL INTERSECTION
PIER (SEE PLAN)
OFFSET WALL
PIER (SEE PLAN)
1. VERTICAL REINFORCEMENT NOT SHOWN FOR CLARITY.
2. PROVIDE STANDARD 90º HOOK AT ENDS OF HORIZONTAL BARS.
3. REFER TO SECTIONS AND DETAILS FOR SIZE & SPACING OF HORIZONTAL REINFORCING.
TYPICAL HORIZONTAL REINFORCEMENT DETAIL AT WALLS & PIERS
BOND BREAKER
3"
3"
FLOOR SLAB
(2) #4 BARS x 4'-0" LONG IN MIDDLE OF
SLAB. PROVIDE BARS AT EACH
CORNER OR RE-ENTRANT CORNER
ADDITIONAL CONTROL JOINTS AT
CORNERS OF FLOOR SLAB - EXTEND
BACK TO MAIN CONTROL JOINT
PATTERN. JOINTS SHALL BE CUT AT A
MAXIMUM OF 45 DEGREES FROM THE
LINE OF THE CORNER.
CORNER OF SLAB,
WALL, TRENCH DRAIN,
EQUIPMENT PAD, ETC.
CONC WALL
4'-0" MIN
M A
X
MIN
1'-0"
1'-0"
WALL FOOTING BOTTOM
REINFORCING
. >/= 45º
MIN
1'-0"
BEAM REFER
TO PLAN
3/16
TYP
1/2" BEARING
PLATE
1/2" GROUT PAD
3/8" STIFFENER
PLATES
M
IN
1 1/2" TYP
11"
1 1/2"
/2
1 1/2"
1'-3"
2"
BEAM REFER TO PLAN
1/2"
2 3/4"
4" 1 1/2"
6"
CENTERLINE OF
STIFFENER PL
BEAM REFER
TO PLAN
3/8" STIFFENER PL
DRILL & EPOXY 3/4"Ø
HILTI HAS B-7 ROD W/
HIT-HY 200 ADHESIVE
1/2" PLATE
1/2" GROUT
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:5
P
M
Scale: As indicated
SC500
TYPICAL FOUNDATION DETAILS
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
18 148
SCALE: 12" = 1'-0"
TYPICAL SLAB CONTROL JOINT AT CORNERS DETAIL
SCALE: 1/2" = 1'-0"
TYP STEPPED WALL FOOTING DETAIL
SCALE: 1" = 1'-0"
BEAM POCKET SECTION
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
1. THE CONTRACTOR SHALL SUBMIT STEEL SHOP DRAWINGS INCLUDING FULLY DEVELOPED FIELD DETAILS FOR REVIEW PRIOR TO
FABRICATION AND ERECTION. MAKE ALL SHOP DRAWINGS FOR ALL WORK CLEARLY SHOWING ALL PIECES, DETAILS AND CONNECTIONS.
CONTRACTOR SHALL DEVELOP AND INCLUDE THEIR OWN ERECTION SHEETS AND FIELD DETAILS. SHOP DRAWINGS MUST BE
INTERNALLY CHECKED BY THE FABRICATOR / DETAILER. UNCHECKED DRAWINGS ARE CAUSE FOR REJECTION.
2. SUBSEQUENT SUBMITTAL AND REVIEW OF 'CORRECTED' SHOP DRAWINGS SHALL INCLUDE APPROPRIATE E-SHEETS WITH EACH REVISION
'CLOUDED' TO ALLOW RAPID TURNAROUND.
3. THE ENGINEERS SIGNATURE ON THE SHOP DRAWINGS IS TO BE INTERPRETED ONLY AS A REVIEW OF THE GENERAL FABRICATION
DESIGN DEVELOPMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS NOTED ON THE SHOP DRAWINGS ALONG WITH ALL
SHOP / FIELD FABRICATION ERRORS.
5. SCALES NOTED ON THE DRAWINGS ARE FOR GENERAL INFORMATION ONLY. NO DIMENSIONAL INFORMATION SHALL BE OBTAINED BY
DIRECT SCALING OF THE DESIGN DRAWINGS (ELECTRONIC OR OTHER MEANS).
6. THE STRUCTURAL DOCUMENTS AND SPECIFICATIONS ARE FOR DEVELOPMENT AND PLACEMENT OF STRUCTURAL COMPONENTS
RELATED TO THIS WORK ONLY. MEANS-AND-METHODS FOR ALL CONSTRUCTION WORK INCLUDING BUT NOT LIMITED TO TEMPORARY
BRACING, CABLES, SHORING OR OTHER MEANS FOR THE SAFE ERECTION OF THE STRUCTURE(S) IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
7. ALL ELEVATIONS SHOWN ON DESIGN DRAWINGS ARE REFERENCED TO FINISH FIRST FLOOR ELEVATION 816'-0" .
8. DESIGN, DETAILING, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE MOST RECENT EDITION OF THE
FOLLOWING PUBLICATIONS EXCEPT AS SPECIFICALLY INDICATED IN THE CONTRACT DOCUMENTS:
A. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL OF STEEL CONSTRUCTION (14th EDITION-ASD) INCLUDING:
-AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
-RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS
B. AMERICAN WELDING SOCIETY STRUCTURAL WELDING CODE D1.1
C. OSHA - 29 CFR PART 1926 - SAFETY STANDARDS FOR STEEL ERECTION, FINAL RULE.
9. REFER TO STRUCTURAL STEEL SPECIFICATIONS FOR DETAILED INFORMATION.
10. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING ASTM SPECIFICATION U.N.O.:
A. W & SPLIT TEES CUT FROM W SHAPES - ASTM A992 GR 50 OR A572 GR 50
B. HSS - SQUARE AND RECTANGULAR -ASTM A500 GR B - 46 KSI
C. HSS - ROUND -ASTM A500 GR B - 42 KSI
D. ROUND PIPE -ASTM A53 TYPE 'E' GRADE B
E. ANGLES, CHANNELS, PLATES -ASTM A36
BARS, BASE PLATES, S-SHAPES, PLATE WASHERS
F. ANCHOR RODS -ASTM F1554 GR 55, SUPPLEMENT S1
G. HEADED STUDS -ASTM A108 Fu = 65KSI
11. UNLESS NOTED OTHERWISE ALL SHOP CONNECTIONS SHALL BE WELDED AND ALL FIELD CONNECTIONS SHALL BE HIGH STRENGTH
BOLTED.
12. ALL STRUCTURAL STEEL BOLTING SHALL USE ASTM A325 HIGH TENSILE BOLTS THAT ARE FULLY TIGHTENED USING THE "TURN OF THE
NUT" METHOD WITH A HARDENED WASHER UNDER THE TURNED ELEMENT AND HEAVY HEX NUTS. LOCK WASHERS AND LOCK NUTS ARE
STRICTLY PROHIBITED. ADDITIONALLY THE USE OF MACHINE BOLTS FOR STRUCTURAL CONNECTIONS IS PROHIBITED. BOLTED
CONNECTIONS SHALL BE DESIGNED WITH ¾ INCH OR LARGER DIAMETER A325-N OR A490-N BEARING TYPE CONNECTIONS, WITH
THREADS INCLUDED IN THE SHEAR PLANE, OR ¾ INCH OR LARGER DIAMETER A325-SC SLIP-CRITICAL CONNECTIONS, U.N.O. DO
NOT MIX BOLT TYPES OR BOLT DIAMETERS IN A CONNECTION.
13. UNLESS OTHERWISE NOTED OR DETAILED, DESIGN ALL BEAM CONNECTIONS TO CONFORM TO AISC STANDARD TWO ANGLE WEB
CONNECTIONS, CAPABLE OF SUPPORTING 75% OF THE BEAM'S TOTAL UNIFORM LOAD CAPACITY (SPAN TIMES AISC TABULATED VALUE
FOR ALLOWABLE UNIFORM LOAD IN KIPS FOR BEAMS LATERALLY SUPPORTED). IN NO CASE SHALL THE BEAM CONNECTION CAPACITY BE
LESS THAN ONE-THIRD THE CALCULATED SHEAR CAPACITY OF THE MEMBER.
14. PROVIDE SLIP-CRITICAL BOLTING, USING CLASS "A" SURFACE VALUES (CLEAN MILL SCALE), AT ALL
COLUMN SPLICES, BRACKETS, BRACING MEMBERS, HANGERS AND MOMENT CONNECTIONS.
SLIP-CRITICAL BOLTS CAN BE USED IN SLOTTED CONNECTIONS IRRESPECTIVE OF THE DIRECTION OF THE STRESS.
15. SHORT HORIZONTAL SLOTS MAY BE USED IN LIEU OF STANDARD HOLES IN THE OUTSTANDING LEGS OF DOUBLE ANGLE BEAM
CONNECTIONS TO GIRDERS AND COLUMNS. DIRECTION OF SUPPORTED REACTION SHALL BE NORMAL TO THE SLOT.
16. THE MINIMUM END CONNECTION OF ANY MEMBER SHALL BE MADE WITH TWO (2) A325 BOLTS OR EQUIVALENT WELD. MINIMUM BOLT
DIAMETER SHALL BE 3/4" UNLESS NOTED.
17. GUSSET PLATES FOR DIAGONAL BRACING SHALL BE CONNECTED TO ALL INTERSECTING MEMBERS UNLESS DETAILED OTHERWISE.
18. VERTICAL BRACING JOINT CONNECTIONS SHALL BE DESIGNED AS SLIP-CRITICAL CONNECTIONS AS DEFINED PER AISC.
19.
ALL WORK POINTS SHALL BE AT THE INTERSECTION OF MEMBERS AND AT COLUMN CENTERLINES, UNLESS NOTED OTHERWISE.
20. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS AND IN ACCORDANCE WITH THE CURRENT AWS D1.1 "STRUCTURAL
WELDING CODE."
21. ELECTRODES FOR WELDING: E70XX SERIES, LOW HYDROGEN FOR SHIELDED METAL ARC GAS, GAS METAL ARC OR FLUX-CORED ARC
WELDING PROCESSES AND E7XX FOR SUBMERGED ARC WELDING UNLESS NOTED OTHERWISE.
22. STORE ELECTRODES IN ACCORDANCE WITH SPECIFICATIONS AND AWS REQUIREMENTS.
23. FILLET WELDS SHALL BE STOPPED SHORT OF A PLATE OR MEMBER EDGE OR PROVIDE AN END RETURN. FOR FILLET WELDS STOPPED
SHORT, THE WELD TERMINATION DISTANCE FROM THE EDGE SHALL BE A MINIMUM OF THE WELD SIZE. FOR FILLET WELDS WITH AN END
RETURN, THE RETURN LENGTH SHALL NOT EXCEED FOUR TIMES THE SIZED OF THE WELD.
24. OVERLAPPING OF WELDS BETWEEN ADJACENT MEMBERS IS STRICTLY PROHIBITED. PROVIDE PROPER OFFSET DISTANCES TO ALLOW
SUFFICIENT ROOM FOR WELDING.
25. MINIMUM FILLET WELD SIZE SHALL BE 3/16", EXCEPT SEAL WELDS MAY BE 1/8".
26. REMOVE ALL EXISTING PAINT, DIRT, RUST OR OTHER SURFACE COATINGS FROM STEEL SURFACES THAT WILL RECEIVE WELD. IN
ADDITION TO STRUCTURAL WELDS, STRUCTURAL STEEL EXPOSED TO WEATHER SHALL HAVE CONTINUOUS SEAL WELDS AT ALL JOINTS
(INCLUDING ALL CONNECTION MATERIAL).
27. ADD AN EXOTHERMIC WELD AT EACH END OF A 4/0 COPPER CONDUCTOR TO 3/4" DIA x 10'-0" LONG COPPER WELD GROUND ROD 2'-0"
BELOW GRADE AT GROUNDED COLUMN LOCATIONS NOTED ON ELECTRICAL GROUNDING PLANS
28. PROVIDE SHELF ANGLES ON COLUMNS AS REQUIRED TO SUPPORT METAL DECK AND WET CONCRETE
29. ANCHOR BOLTS, SETTING DIAGRAMS, AND TEMPLATES SHALL BE SUPPLIED BY THE STEEL CONTRACTOR AND SET PLUMB AND VERTICAL
BY THE FOUNDATION CONTRACTOR. PROVIDE (1) LEVELING NUT PER ANCHOR ROD OR (1) SHIM PACK IN FULL BEARING AT EACH CORNER OF
30. ALL PROJECTED CORNERS, BURRS, EXPOSED EDGES AND SHARP CORNERS SHALL BE GROUND SMOOTH.
VERTICAL CROSS-BRACING MEMBER CONNECTIONS SHALL BE SIZED FOR THE MEMBER FORCES WHEN SHOWN ON THE DRAWINGS, BUT NOT LESS THAN 50% OF THE MEMBER'S GROSS SECTION TENSILE CAPACITY.
STRUCTURAL STEEL CONNECTIONS NOTED ON THESE DOCUMENTS ARE FOR GENERAL CONNECTION CONFIGURATION ONLY. THE CONTRACTOR SHALL RETAIN A QUALIFIED ENGINEER LICENSED IN THE STATE OF MICHIGAN TO DESIGN ALL STRUCTURAL STEEL CONNECTIONS. SUBMIT CONNECTION CALCULATIONS FOR REVIEW PRIOR TO THE COMMENCEMENT OF FABRICATION ACTIVITIES.
ALL STEEL EXPOSED TO WEATHER SHALL BE HOT DIP GALVANIZED.
ALL LOADS, FORCES AND REACTIONS ARE UNFACTORED SERVICE LOADS (ASD).
ALL CONNECTIONS SHALL BE DESIGNED FOR A MINIMUM SERVICE LOAD OF 6K.
ALL STEEL DECK SHALL BE INSTALLED WITH AT LEAST 1 1/2" END BEARING.
NO ATTACHMENTS OR CONNECTIONS SHALL BE MADE TO STEEL FLOOR OR ROOF DECK OTHER THAN THOSE SHOWN ON THE
DRAWINGS WITHOUT PRIOR APPROVAL FROM THE ENGINEER OF RECORD.
ROOF DECK CONNECTIONS UNLESS OTHERWISE NOTED:
ROOF DECK @ SUPPORTS: 24/4 PATTERN, 5/8" DIA PUDDLE WELD OR (1) #10 TEK SCREW
ROOF DECK @ SIDELAPS: (3) #10 TEK SCREWS / SPAN
FORM DECK @ SUPPORTS: 36/4 PATTERN, 5/8" DIA PUDDLE WELD (ONLY WHERE HEADED STUDS NOT REQUIRED) FORM DECK @ SIDELAPS: (2) 5/8" DIA PUDDLE WELDS OR (2) 3/8" x 1 1/4" ARC SEAM WELDS / SPAN
"BUTTON PUNCHED CONNECTIONS ARE NOT PERMITTED"
ALL STEEL ROOF DECK SHALL BE 3" x 20 GA TYPE N
ALL STEEL FLOOR DECK SHALL BE 1 1/2" x 20 GA TYPE C
MINIMUM GUSSET PLATE THICKNESS SHALL BE 3/8"
NO FLAME CUTTING IS PERMITTED IN THE FIELD WITHOUT ENGINEER APPROVAL. THIS INCLUDES CUTTING OF STEEL. CORRECTING MISALIGNED PIECES AND ENLARGING OR ADDING HOLES. BURNT HOLES IN THE SHOP OR FIELD FABRICATION ARE PROHIBITED.
ALL FULL PENETRATION (CJP) AND PARTIAL PENETRATION (PJP) WELDS SHALL BE INSPECTED BY ULTRASONIC TESTING (UT).
ALL WELDS SHALL BE UNIFORM IN SIZE AND APPEARANCE AND SHALL BE FREE OF PINHOLES, CRACKS, UNDERCUTTING, OR OTHER
DEFECTS.
REPLACE OR SUPPLEMENT UNDER DRIVEN OR OVER DRIVEN DECK FASTENERS WITH ADJACENT, PROPERLY INSTALLED
FASTENERS.
DO NOT USE STEEL DECK FOR STORAGE OR AS A WORK PLATFORM UNTIL DECK IS PERMANENTLY FASTENED TO SUPPORTING
STEEL FRAMING.
ALL STEEL DECK SHALL BE PRIME PAINTED ON BOTH SIDES. FINISH PAINT AND / OR GALVANIZING IS NOT REQUIRED. PROVIDE RUST
INHIBITIVE PRIMER TO A NOMINAL THICKNESS OF 4 MICRONS.
THE LENGTH OF CONNECTION ANGLES OR SHEAR TABS SHALL EXCEED ONE HALF THE DEPTH OF THE SUPPORTED MEMBER.
DO NOT PAINT AREAS WITHIN 3" OF LOCATIONS TO BE FIELD WELDED OR WITHIN 3" OF SLIP CRITICAL BOLTED CONNECTIONS.
ELECTRODES WITH CHARPY V NOTCH TEST VALUES OF AT LEAST 20 FT-LB @ -20 DEG F ARE REQUIRED AT ALL CJP AND PJP WELDS.
GROUT BELOW COLUMN BASES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF AT LEAST 7000 PSI AND CONFORM TO ASTM
C1107. GROUT SHALL BE PRE-MIXED, NON-METALLIC, NON SHRINK GROUT.
31.
32.
THE OWNER'S TESTING AGENCY. THE CONTRACTOR SHALL PROVIDE ACCESS TO THE INSPECTORS IN A TIMELY
BUILDING CODE AND DESIGN STANDARDS
STRUCTURES ARE DESIGNED IN ACCORDANCE WITH THE FOLLOWING BUILDING CODES AND STANDARDS:
1. INTERNATIONAL BUILDING CODE 2015.
2. AMERICAN SOCIETY OF CIVIL ENGINEERS SEI/ASCE 7-10.
3. VA STRUCTURAL DESIGN MANUAL FOR REGIONAL OFFICE PROJECTS (FEB. 1, 2014)
4. VA HANDBOOK H-18-8 "SEISMIC DESIGN REQUIREMENTS"
5. VA DESIGN ALERTS AND QUALITY ALERTS.
6. STRUCTURE IS NOT DESIGNED FOR FUTURE VERTICAL AND/OR HORIZONTAL EXPANSION.
DESIGN LOADS
1. ROOF LOADS
a. DEAD LOADS:
i. STEEL DECK = 3 PSF
STEEL FRAMING = 7 PSF
UTILITIES = 5 PSF
CEILING GRID = 1 PSF
RIGID INSULATION = 6 PSF
ROOFING = 3 PSF
TOTAL = 25 PSF
ii. ROOF TOP UNIT = 2600 LB
b. ROOF LIVE LOAD
i. 20 PSF
2. SUPPORTED FLOOR LOADS:
a. DEAD LOADS:
i. 5" CONCRETE SLAB = 57 PSF
STEEL DECK = 3 PSF
CEILING GRID = 1 PSF
UTILITIES = 5 PSF
STEEL FRAMING = 7 PSF
FLOORING = 2 PSF
TOTAL =75 PSF
b. SUPPORTED FLOOR UNIFORM LIVE LOADS
i. OFFICE AREAS 80 PSF
ii. STAIRS 100 PSF
iii. CORRIDORS 100 PSF
iv. PARTITION ALLOWANCE 20 PSF v.CONCENTRATED LOAD = 2500 LB OVER 2.5 S.F.
3. SLAB-ON-GRADE LIVE LOADS:
a. FIRST FLOOR 100 PSF
b. MECHANICAL ROOMS, AREAWAY AND BASEMENT FLOOR 150 PSF
4. SNOW LOAD
a. GROUND SNOW LOAD, Pg = 20 PSF
b. FLAT ROOF SNOW LOAD, Pf = 20 PSF
c. SNOW EXPOSURE FACTOR, Ce = 1.0
d. THERMAL FACTOR, Ct = 1.0
e. SNOW LOAD IMPORTANCE FACTOR, I = 1.0
f. SNOW DRIFT LOADS AND SLIDING SNOW LOADS IN ACCORDANCE WITH ASCE 7-10.
5. WIND LOADS (MWFRS)
a. BASIC WIND SPEED (3 SECOND GUST), V = 115 MPH
b. DIRECTIONAL PROCEDURE
c. RISK CATEGORY II
d. EXPOSURE CATEGORY C
e. INTERNAL PRESSURE COEFFICIENT, GCp = +\- 0.18
f. COMPONENTS AND CLADDING WIND PRESSURE (SEE WIND LOADING DIAGRAMS)
g. ENCLOSED BUILDING
h. kz = 1.0
i. kD = 0.85
j. kz = VARIES 0.85 TO 1.05
k. G = 0.85
6. SEISMIC LOADS
a. RISK CATEGORY = II
b. SEISMIC IMPORTANCE FACTOR, Ie = 1.0
c. SITE CLASS D
d. SEISMIC DESIGN CATEGORY = B
e. MAPPED SPECTRAL ACCELERATION
i. SPECTRAL RESPONSE COEFFICIENT, Ss = 0.12 g
ii. SPECTRAL RESPONSE COEFFICIENT, S1 = 0.045 g
f. SDs = 0.13 g
g. Sd1 = 0.07 g
h. BASIC SEISMIC FORCE RESISTING SYSTEM(S): STEEL SYSTEM NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE
i. RESPONSE MODIFICATION FACTOR, R = 3
j. SEISMIC RESPONSE COEFFICIENT(S), Cs = 0.043
k. DESIGN BASE SHEAR, V = 0.043 * W
l. ANALYSIS PROCEDURE = EQUIVALENT LATERAL FORCE PROCEDURE
33.
STEEL GENERAL NOTES:
MANNER SO AS NOT TO DELAY THE WORK. ITEMS THAT FAIL INSPECTION SHALL BE CORRECTED TO THE
AND TESTING SERVICES IN ACCORDANCE WITH SECTION 1704 OF THE IBC. TO DETERMINE CONTRACTOR COMPLIANCE
SATISFACTION OF THE INSPECTOR AT NO COST TO THE OWNER.
EMPLOYED BY THE CONTRACTOR FOR QUALITY CONTROL OR DESIGN SERVICES SHALL NOT BE CONNECTED WITH WITH THE CONTRACT DOCUMENTS. COSTS OF SUCH SERVICES WILL BE BORNE BY THE OWNER. ANY TESTING AGENCY
1. THE OWNER WILL EMPLOY ON THEIR OWN BEHALF AN INDEPENDENT TESTING AGENCY TO PERFORM INSPECTION
SPECIAL INSPECTION
34.
35.
3 2 3
2 1
TYP
7'-0".
T Y
P
COMPONENTS & CLADDING WIND PRESSURE PER ASCE 7-1C
- ALL LOADS SHOWN ARE BASED ON 115MPH WIND
- SERVICE LEVEL (ASD) LOADS ARE SHOWN
- LOADS ARE UNFACTORED AND UNREDUCED
ZONE 1 = 36 PSF
ZONE 2 = 60PSF
ZONE 3 = 90 PSF
ROOF UPLIFT PLAN
N
TYP
7'-0".
TYP
7'-0".
(REFER TO PLAN)
WALL LENGTH
(R E
F E
R T
O P
L A
N
W A
L L H
E
IG
H T
5 4 5
WALL PRESSURE ELEVATION
COMPONENT AREA
(SQ. FT)
ZONE WALL PRESSURE
(PSF)
<10 4 35
25 4 32
50 4 29
>100 4 27
<10 5 44
25 5 37
50 5 31
>100 5 27
WALL PRESSURE IS POSITIVE OR NEGATIVE (SUCTION)
7. MISCELLANEOUS LOADS
a. HANDRAIL/GUARDRAIL: 200 LB OR 50 LB/FT APPLIED IN ANY DIRECTION
b. FIXED LADDER: 300 LB @ CENTER OF RUNG
c. CONSTRUCTION LIVE LOAD = 20 PSF
d. INTERIOR HORIZONTAL PRESSURE ON PERMANENT WALLS = 5 PSF
e. ELEVATOR WEIGHT = 5k + IMPACT
f. LEKTRIEVER CAROUSEL = 8,973 LB (MODEL 115_1411X OPERATING WEIGHT)
NOTE:CONTACT VA REPRESENTATIVE FOR INSTRUCTIONS ON RELOCATING
EQUIPMENT FROM OTHER VA FACILITY. EQUIPMENT MAY NOT BE PLACED
OUTSIDE OF AREA DESIGNATED ON 2nd FLOOR FRAMING PLAN.
8. DELEGATED DESIGN ITEMS
a. THE FOLLOWING ITEMS ARE TO BE DESIGNED BY THE CONTRACTOR. STRUCTURAL CALCULATIONS SHALL BE SIGNED AND SEALED BY PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF MICHIGAN AND
SUBMITTED TO THE EOR FOR REVIEW PRIOR TO STARTING FABRICATION:
i. INTERIOR AND EXTERIOR STAIRCASES AND RAILINGS
ii. COLD FORM MEMBERS AND STOREFRONT FRAMING
iii. ALL STRUCTURAL STEEL CONNECTIONS.
4. ALL ROOF AND FLOOR STEEL DECK SHALL BE INSTALLED CONTINUOUS OVER 3 OR MORE SPANS.
H. HEAVY HEX NUTS -ASTM A563
I. HARDENED WASHERS -ASTM F436
BASE PLATE.
CONSTRUCTION MANUAL, 14th ED. REFER TO THE FOLLOWING TABLES FOR REQUIRED INSPECTIONS:
2. SPECIAL INSPECTION SHALL CONFORM TO "CHAPTER N QUALITY CONTROL AND QUALITY ASSURANCE" OF THE AISC STEEL
TABLE N5.4-1 INSPECTION TASKS PRIOR TO WELDING
TABLE N5.4-2 INSPECTION TASKS DURING WELDING
TABLE N5.4-3 INSPECTION TASKS AFTER WELDING
TABLE N6.6-1 INSPECTION TASKS PRIOR TO BOLTING
TABLE N6.6-2 INSPECTION TASKS DURING BOLTING
TABLE N6.6-3 INSPECTION TASKS AFTER BOLTING
TABLE N6.1 INSPECTION OF STEEL ELEMENTS OF COMPOSITE
CONSTRUCTION PRIOR TO CONCRETE PLACEMENT.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:5
P
M
Scale: 12" = 1'-0"
SS001
STRUCTURAL STEEL GENERAL NOTES
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
19 148
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
A
B
B
C
C
D
D
H
E
E
4.2
J
2.8
W X
(2
W X
(2
W X
(2
W21X73W18X55W16X26
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
W X
W X
W X
W X
W X
W10X15
W X
W X
(2
W X
(2
W X
W12X35
3 1/2" NW CONCRETE SLAB ON
1 1/2" - 20GA NON-COMPOSITE
METAL DECK W/ DRAPED
4x4 - W4.0xW4.0 WWF
WWF SHALL BE 1" FROM TOP OF
SLAB OVER BEAMS
(5" TOTAL THICKNESS)
30'-8" 32'-8" 23'-6" 24'-6 11/16"
4'-10"
13'-8" 17'-0" 32'-8" 23'-6" 15'-10" 9'-11"
8.00°
111'-4 11/16"
102'-8"
1'-4" 15'-9"
4.8
/ 8
'-4
F-1
5" CONCRETE SLAB ON GRADE W/
#3@12" OC EW, 2" FROM T/SLAB
FIN FLR EL = 816'-0"
W X
W X
(2
W X
W10X12
W12X26
W X
AREAWAY
G
7'-9"
W X
W14X43
W X
(1
W X
(1
W X
(2
W X
SC300
SC300
W X
(2
SC300
SC300
CONTROL OR
CONSTRUCTION JOINT
REFER TO TYP DETAIL
SHEET SC500
SC300
SC300
SC300
SC300
W X
1'-3"
2'-0" 3'-6" 6'-1 1/2" 4'-11" 4'-11"
F K
5" CONCRETE SLAB ON GRADE W/
#3@12" OC EW, 2" FROM T/SLAB
FIN FLR EL = 816'-0"
W X
(1
1'-6"
5.4
SC300
13'-8" 17'-0"
1'-6"
SC300
A
SC300
A
SC300
SC300
SC300 8
SC300
SC300
A
"4
SC301
SC301
6'-0" 6'-3"
4'-4".
3" 17'-5" 5'-10"
/2
5'-9".
1'-2".
SS301
SS301
SS301
8'-3"
4'-0" 4'-9" 2'-2"
/2
4'-10 1/2" 6'-0 7/8"
SS301
DENOTES VERT BRACING TYP
REFER TO SS200
5'-0"
INDICATES VERT
BRACING REFER
TO SS200
/1
NO. OF 3/4"Ø x 4" LG SHEAR
CONNECTORS FOR COMPOSITE
BEAM OR GIRDER
(UNIFORMLY SPACED)
W14x22 (N)
BEAM LEGEND
MOMENT CONNECTION
NOTES:
1. REFER TO DRAWING SS001 FOR GENERAL NOTES.
2. REFERT O DRAWING SS600 FOR COLUMN SCHEDULE.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:5
P
M
Scale: As indicated
SS110
FIRST FLOOR FRAMING PLAN
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
20 148
SCALE: 3/16" = 1'-0"
FIRST FLOOR FRAMING PLAN
N
FIN FLR EL = 816'-0"
T/STL EL = 815'-7"
REFER TO
SECTION 9/SS301
FOR MOMENT
CONN
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
B C
C
D
D
H
E
E
4.2
J
W X
(2
W24X94
H S
S X
X
/2
W X
W24X94
W21X147
W27X114
W X
W18X65
W18X55
W X
(2
W X
(1
W X
(2
W16X57
W X
(1
W24X103W24X103
W X
(1
W10X30
W X
(1
W12X35
W X
(1
W24X94
W X
W30X124
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W12X35
W X
W10X12
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
W X
W X
W X
W X
(1
W X
(1
W X
(1
W X
(1
W X
(1
W X
(1
W X
(2
W X
(2
W X
(2
W X
(1
W X
W10X33 W16X36
W21X73
W10X15
W X
(2
W X
(2
W X
W X
(2
W X
(2
W X
2.8
30'-8" 32'-8" 23'-6" 24'-6 11/16"
F B
P
/1
13'-8" 17'-0" 32'-8" 23'-6" 15'-10" 9'-11"
8.00°
111'-4 11/16"
4.8
W X
W10X22
W14X26
W X
6'-6 3/8" 6'-6 3/8" 6'-6 3/8" 7'-0" 6'-0 7/8".
3" - 20 GA METAL
ROOF DECK
G
W X
(2
W X
(1
W X
(1
W X
W X
W X
W X
(2
W X
W12X30
F A
C E
O F
B E
N T
P L A
T E
F
B P
8" FBP 8" FBP
F B
P
F B
P
8" FBP
F B
P
8" FBP
8" FBP
F
K
K
W18X65
W X
(2
W14X43
W X
(1
/2 " 4'-0" 4'-9" 2'-2"
1'-3"
2'-0" 5'-6" 5'-6" 4'-11" 4'-11"
14'-8 9/16"
W X
5.4
W8X13
W8X13
W8X13
W8X13
W8X13
W X
W X
11'-3"
1'-0 1/8"
3'-0"
4'-10"
7'-9"
/1 "9
/4
20'-2 15/16" 9 11/16"
W X
W10X19
1'-1"
W X
(2
3 1/2" NW CONCRETE SLAB ON
1 1/2" - 20GA NON-COMPOSITE
METAL DECK W/ DRAPED
4x4 - W4.0xW4.0 WWF
WWF SHALL BE 1" FROM TOP OF
SLAB OVER BEAMS
(5" TOTAL THICKNESS)
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS301
SS301
SS300
SS300
SS301
SS301
SS301
/2
5'-9".
1'-2".
SS301
SS301
MOMENT CONNECTION
TYP REFER TO
SECTION '8/SS301'
8'-3"
T O
S E
L
A L O
N G
'K
T O
S E
L
A L O
N G
'F
V
E S
T R
O O
F
LEKTRIEVER LOCATION
SEE NOTE 7 ON SS001
L L V
INDICATES VERT
BRACING REFER
TO SS200 TYP
5'-0"
SS300
SS300
NO. OF 3/4"Ø x 4" LG SHEAR
CONNECTORS FOR COMPOSITE
BEAM OR GIRDER
(UNIFORMLY SPACED)
W14x22 (N)
BEAM LEGEND
MOMENT CONNECTION
NOTES:
1. REFER TO DRAWING SS001 FOR GENERAL NOTES.
2. REFERT O DRAWING SS600 FOR COLUMN SCHEDULE.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:0
P
M
Scale: As indicated
SS120
SECOND FLOOR FRAMING PLAN
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
21 148
SCALE: 3/16" = 1'-0"
SECOND FLOOR FRAMING PLAN
N
FIN FLR EL = 829'-4"
T/STL EL = 828'-11"
REFER TO
SECTION 9/SS301
FOR MOMENT
CONN
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
B C
C
D
D
H
E
E
4.2
J
W X
(2
W24X94
H S
S X
X
/8
W X
W24X94
W21X147 W27X114
W X
W18X65
W18X55
W X
(2
W X
(1
W X
(2
W16X57
W24X103W24X103
W X
(1
W10X30
W X
(1
W12X35
W X
(1
W24X94
W X
W30X124
W X
(2
W X
(2
W X
(2
W X
(1
W X
(1
W X
(1
W12X35
W X
W8X10
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
(2
W X
W X
W X
W X
W X
(1
W X
(1
W X
(1
W X
(1
W X
(1
W X
(1
W X
(2
W X
(2
W X
(2
W X
(1
W X
W10X33 W16X36
W21X73
W X
(2
W X
(2
W X
(2
W X
(2
W X
2.8
30'-8" 32'-8" 23'-6" 24'-6 11/16"
8.00°
4'-10"
7'-9"
13'-8" 17'-0" 32'-8" 23'-6" 15'-10"
111'-4 11/16"
W X
(1
W X
(2
W X
W10X22
W10X22
W X
W X
(1
6'-6 3/8" 6'-6 3/8" 6'-6 3/8" 7'-0" 6'-0 7/8".
G
W14X43
W X
(2
W X
(1
W X
(1
W X
W X
F A
C E
O F
B E
N T
P L A
T E
F
B P
8" FBP 8" FBP
F B
P
F B
P
F B
P
8" FBP8" FBP
F
4'-0" 4'-9" 2'-2"
/2
1'-3" 2'-0" 5'-6" 5'-6" 4'-11" 4'-11"
W X
(2
W18X65
W X
(2
W X
W12X30
W X
W10X15
W X
W X
14'-8 9/16"
8" FBP
3/8" STIFFENER PLATES &
KICKERS @ 4'-0" OC TYP
REFER TO SECTION ON
DRAWING SS300
3 1/2" NW CONCRETE SLAB ON
1 1/2" - 20GA NON-COMPOSITE
METAL DECK W/ DRAPED
4x4 - W4.0xW4.0 WWF
WWF SHALL BE 1" FROM TOP OF
SLAB OVER BEAMS
(5" TOTAL THICKNESS)
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS301
SS301
SS301
SS301
SS301
/1 "9
/4
20'-2 15/16" 9 11/16"
/2
5'-9".
1'-2".
L L V
11'-3" 1'-0 1/8"
8'-3"
INDICATES VERT
BRACING REFER
TO SS200
8" FBP
SS300
.0
/1
SS300
SIM
8" FBP
SS300
3/8" STIFFENER PLATES &
KICKERS @ 4'-0" OC TYP
REFER TO SECTION ON
DRAWING SS300
SS301
NO. OF 3/4"Ø x 4" LG SHEAR
CONNECTORS FOR COMPOSITE
BEAM OR GIRDER
(UNIFORMLY SPACED)
W14x22 (N)
BEAM LEGEND
MOMENT CONNECTION
NOTES:
1. REFER TO DRAWING SS001 FOR GENERAL NOTES.
2. REFERT O DRAWING SS600 FOR COLUMN SCHEDULE.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:0
P
M
Scale: As indicated
SS130
THIRD FLOOR FRAMING PLAN
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
22 148
SCALE: 3/16" = 1'-0"
THIRD FLOOR FRAMING PLAN
N
FIN FLR EL = 842'-8"
T/STL EL = 842'-3"
REFER TO
SECTION
9/SS301 FOR
MOMENT CONN
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
B C
C
D
D
6 6
5 5
3 3
2 2
H
E
E
4.2
4 4
J
9" FBP
30'-8" 32'-8" 23'-6" 24'-6 11/16"
W16X40
W X
W14X38
W X
W14X26
W14X22
W X
W X
W X
W X
W X
W10X15
W18X55
W X
W X
W10X19 W14X34
W X
W18X55
W18X71
W X
W X
W16X36W18X60W18X60
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
W14X38
W14X43 W14X22 W8X18
W X
W X
W X
W X
W X
W X
W X
W X
3" - 20GA METAL ROOF DECK
2.8
/1
F B
P
8.00°
4'-10"
7'-9"
111'-4 11/16"
13'-8" 17'-0" 32'-8" 23'-6" 15'-10"
C8x11.5 TYP FRAME
@ ROOF HATCH
VERIFY SIZE &
LOCATION W/ ARCH
S10x25.4
HOIST BEAM
(B/HOIST BEAM = 855'-0")
REFER TO '1/SS301'
G
W X
W X
W X
W X
C8x11.5 FRAME @
ROOF SUMPS &
OVERFLOWS, TYP
VERIFY SIZE &
LOCATION WITH
ARCH & PLUMBING
DRAWINGS
W X
W10X22
5'-0" 9" FBP
T/STL EL=
856'-5 7/8"
F
W X
W14X26
W X
8" CMU GROUTED SOLID WALLS
W/ #4@24" OC VERT PROVIDE
BOND BEAM @ EA FLOOR & AT
EA RAIL ATTACHMENT (SINGLE
COURSE W/ 1 #4)
F B
P
F B
P
9" FBP
F B
P
9" FBP
F B
P
9" FBP
F B
P
9" FACE OF BENT PLATE
F B
P
9" FBP
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
SS300
3" - 20GA METALROOF DECK(B/DECK EL 857'-4")
SS301
W10X22
W10X22
W X
1H-1 313#
VRV-1
554#
HSS4X4X1/4
HSS4X4X1/4
REFER TO MECH
DRAWINGS FOR
UNIT SIZE,
LOCATION AND
CURB DETAILS
W X
W12X19
8'-3"
9'-0" 6'-10"
SS300
SS300
SIM
W10X22
W10X22
W10X22
W X
W10X22 W10X22
W10X22W10X22
W X
W X
ACCU-01
2578#
SS300
SS300
SS300
NOTES:
1. REFER TO DRAWING SS001 FOR GENERAL NOTES.
2. REFERT O DRAWING SS600 FOR COLUMN SCHEDULE.
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:0
P
M
Scale: As indicated
SS140
ROOF FRAMING PLAN
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
23 148
SCALE: 3/16" = 1'-0"
ROOF FRAMING PLAN
N
T/STL EL - REFER TO PLAN
T/STL EL = 856'-11 5/8"
@ HP ALONG LINE 7
T/STL EL = 856'-11 1/4"
ALONG LINE 6
T/STL EL = 856'-7 5/8"
ALONG LINE 5
T/STL EL = 856'-5 5/8"
ALONG LINE 4
T/STL EL = 856'-0" @
LP ALONG LINE 3
T/STL EL = 856'-5 3/4"
ALONG LINE 2
T/STL EL = 856'-6 1/8"
ALONG LINE 1
T/STL EL =
856'-1 1/16"
T/STL EL =
856'-0 3/4"
INDICATES VERT
BRACING REFER
TO SS200
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
FIRST FLOOR
816'-0"
SECOND FLOOR
829'-4"
THIRD FLOOR
842'-8"
D E
FOUNDATION PLAN
801'-0"
23'-6"
T/STL EL - REFER TO PLAN
W14X43
W16X57
W16X57
HSS6X6X1/4
HSS5X5X3/8
HSS6X6X5/8
10K
20K
43K
REFER TO
COLUMN
SCHEDULE
SS200
SS200
FIRST FLOOR
816'-0"
SECOND FLOOR
829'-4"
THIRD FLOOR
842'-8"
CD
FOUNDATION PLAN
801'-0"
T/STL EL - REFER TO PLAN
32'-8"
W16X40
W24X94
W24X94
H
SS4X
4X 1/
H
SS4X4X1/4
HSS4X4X1/
HSS4X4X1/4
HSS5X5X1/4
H
SS5X
5X 1/
6K
6K
K
6K
6K
12K
REFER TO
COLUMN
SCHEDULE
SS200
SS200
FIRST FLOOR
816'-0"
SECOND FLOOR
829'-4"
THIRD FLOOR
842'-8"
T/STL EL - REFER TO PLAN
23'-0"
HSS5X5X3/8
HSS6X6X1/4
HSS6X6X5/8
W12X40
HSS14X6X5/8
HSS14X6X1/2
9K
20K
43K
REFER TO
COLUMN
SCHEDULE
SS200
SS200
FIRST FLOOR
816'-0"
SECOND FLOOR
829'-4"
THIRD FLOOR
842'-8"
4.2 2.8
T/STL EL - REFER TO PLAN
W12X40
W27X114
W27X114
26'-7"
HSS5X5X3/8
HSS8X6X1/4
HSS10X6X1/2
REFER TO
COLUMN
SCHEDULE
8K
19K
42K
SS200
SS200
BEAM REFER
TO PLAN
COLUMN
REFER TO
PLAN &
SCHED
W.P.
BRACE REFER TO
ELEVATIONS
3/8" GUSSET
PLATE (MIN)
3/16
3/16
MIN
1/2"Ø ERECTION BOLT
6".
MIN
MIN 3/16
3/16
MIN TYP
MIN
M
IN
6"
BEAM REFER TO PLAN
BRACE
3/8" GUSSET PLATE (MIN)
1/2"
ERECTION
BOLT
BRACE
WP
COLUMN WEB PERPENDICULAR TO PLANE OF BRACE
WP @ T/BASE PLATE
COLUMN
BRACE
3/8" GUSSET
PLATE (MIN)
TYP. BRACE CONN. DETAIL AT BASE
6" M
IN (TYP)
3/16
3/16
MIN TYP
1/2"Ø
ERECTION
BOLT
MIN
WP @ T/BASE PLATE
COLUMN REFER TO
PLAN & SCHEDULE
BRACE
3/8" GUSSET
PLATE (MIN)
TYP. BRACE CONN. DETAIL AT BASE
COLUMN WEB IN PLANE OF BRACE.
3/16
3/16
MIN TYP
6"
MIN
M
IN
1/2"Ø
ERECTION
BOLT
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:0
P
M
Scale: As indicated
SS200
BRACE BAY ELEVATIONS & DETAILS
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
24 148
SCALE: 1/8" = 1'-0"
BRACED BAY ALONG 4
SCALE: 1/8" = 1'-0"
BRACED BAY ALONG 1
SCALE: 1/8" = 1'-0"
BRACED BAY ALONG A
SCALE: 1/8" = 1'-0"
BRACED BAY ALONG J
SCALE: 3/4" = 1'-0"SS200
5 SECTION
SCALE: 3/4" = 1'-0"SS200
6 SECTION
SCALE: 3/4" = 1'-0"
7 SECTION
SCALE: 3/4" = 1'-0"SS200
8 SECTION
NOTES:
1. ALL BRACE FORCES SHOWN ARE MAXIMUM FORCES
FROM THE GOVERNING LOAD COMBINATION WHICH IS NOT
NECESSARILY THE SAME FOR EACH BRACE.
2. BRACE FORCES SHOWN ARE AXIAL FORCES AND SHALL BE
TAKEN AS TENSION OR COMPRESSION.
SS200SS200SS200 SS200
DESIGN DEVELOPMENT SUBMISSION 1 04-19-16
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
FIN FLR EL
@ 2nd FLOOR
REFER TO PLAN
CFMF & SPLICE
REFER TO ARCH
BEAM REFER TO PLAN
RIGID
INSULATION
REFER TO ARCH
R E
F E
R T
O P
L A
N
FINISH REFER
TO ARCH
REFER TO PLAN
CONT 1/4x8x5 BENT PLATE W/ 1/2"Ø x12"
LONG HEADED
STUDS @ 18" OC
CFMF HEADER
@ OPENINGS
ONLY
1'-6"
1'-6"
FIN FLR EL
@ 3rd FLOOR
REFER TO PLAN
CFMF & SPLICE
REFER TO ARCH
BEAM REFER TO PLAN
CONT L5x5x3/8 W/ VERT
SLOTTED HOLES W/ 5/8"Ø
ERECTION BOLT - 3/16" WELD
ALL AROUND AFTER ALIGNMENT
BOTT OF RELIEF ANGLE
RIGID
INSULATION
REFER TO ARCH
R E
F E
R T
O P
L A
N
FINISH REFER
TO ARCH
1'-0 1/2"
KICKER @ 4'-0" OC
REFER TO KICKER
SCHEDULE ON
SS500
REFER TO PLAN
CONT 1/4" BENT
PLATE W/ 1/2"Ø x12"
LONG HEADED
STUDS @ 18" OC
1/4" GUSSET
PLATE TYP
L4x4x1/4 CLIP W/ HORIZ
SLOTTED HOLES W/
5/8"Ø ERECTION BOLT
3/16" WELD ALL AROUND
AFTER ALIGNMENT
3/8" FULL DEPTH
STIFFENER @ 4'-0" OC
CFMF HEADER
@ OPENINGS
ONLY
FACE OF STIFFENER
1'-6"
CFMF
REFER TO ARCH
CFMF & SPLICE
REFER TO ARCH
BEAM REFER TO PLAN
RIGID
INSULATION
REFER TO ARCH
3" METAL DECK
REFER TO
PLAN
CONT 1/4" BENT PLATE
W/ 4" VERT LEG
FINISH REFER
TO ARCH
REFER TO PLAN
CFMF HEADER
@ OPENINGS
ONLY
1'-6"
FIN FLR EL
REFER TO PLAN
CFMF & SPLICE
REFER TO ARCH
BEAM REFER TO PLAN
CONT L5x5x3/8 W/ VERT
SLOTTED HOLES W/ 5/8"Ø
ERECTION BOLT - 3/16" WELD
ALL AROUND AFTER ALIGNMENT
BOTT OF RELIEF ANGLE
RIGID
INSULATION
REFER TO ARCH
FINISH REFER
TO ARCH
1'-0 1/2"
L4x4x1/4 CLIP W/ HORIZ
SLOTTED HOLES W/
5/8"Ø ERECTION BOLT
3/16" WELD ALL AROUND
AFTER ALIGNMENT
3/8" FULL DEPTH
STIFFENER @ 4'-0" OC
CFMF HEADER
@ OPENINGS
ONLY
FACE OF STIFFENER
FIN FLR EL
REFER TO PLAN
CFMF & SPLICE
REFER TO ARCH
BEAM REFER TO PLAN
RIGID
INSULATION
REFER TO ARCH
R E
F E
R T
O P
L A
N
FINISH REFER
TO ARCH
REFER TO PLAN
CONT 1/4" BENT
PLATE W/ 1/2"Ø x12"
LONG HEADED
STUDS @ 18" OC
CFMF HEADER
@ OPENINGS
ONLY
1'-2 3/8"
CFMF & SPLICE
REFER TO ARCH
BEAM REFER TO PLAN
RIGID
INSULATION
REFER TO ARCH
FINISH REFER
TO ARCH
CFMF HEADER
@ OPENINGS
ONLY
1'-2 3/8"
CFMF
REFER TO ARCH
3" METAL DECK
REFER TO
PLAN
CONT 1/4" BENT PLATE
W/ 4" VERT LEG
REFER TO PLAN
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:1
P
M
Scale: 3/4" = 1'-0"
SS300
FRAMING SECTIONS
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
25 148
SCALE: 3/4" = 1'-0"SS120
7 SECTION
SCALE: 3/4" = 1'-0"SS130
4 SECTION
SCALE: 3/4" = 1'-0"SS140
1 SECTION
SCALE: 3/4" = 1'-0"SS130
10 SECTION
FIELD WELD ENDS
OF HSS TO
COLUMNS W/
5/16" FILLET WELD
ALL AROUND
SCALE: 3/4" = 1'-0"SS120
2 SECTION
SCALE: 3/4" = 1'-0"SS140
3 SECTION
SS130
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
L BM &
BP
C
L W
A L L
B P
C
TYP
1 1/2"
NOTE: FILL BEAM POCKET SOLID W/ NON-
SHRINK GROUT AFTER SHEAVE BEAM
IS INSTALLED
(2) 3/4"Ø x6" LG
HEADED STUDS
1/2" NON-SHRINK
GROUT
10"x5"x1/2" PL
3/8" THK STIFFENER
LOCATED 2 1/2"
FROM EACH END OF
BEAM
S10x25.4
3/16 5
TYP 3/16
TYP
T/ CMU SEE
ARCH.
FIN FLR EL
829'-4" @ 2ND FLOOR
BEAM REFER TO PLAN
R E
F E
R T
O P
L A
N
1'-0"
REFER TO PLAN 8"
REFER TO PLAN .
TOS EL=827'-11"
FINISH REFER
TO ARCH
DRAWINGS
METAL ROOF DECK
REFER TO PLAN
1/4" BENT PLATE
W/ 3" VERT LEG
F
TOS EL=827'-8"
FIN FLR EL
829'-4" @ 2ND
FLOOR
BEAM REFER TO PLAN
1'-9"
1'-8 11/16" 1'-2" 7"
TOS EL=827'-11" @ HP
METAL ROOF DECK
REFER TO PLAN
1/4" BENT PLATE
W/ 3" VERT LEG
4.2
TOS EL=828'-11"
TOS EL=829'-3 1/4"
1'-3" 6"
3"
FINISH REFER
TO ARCH
COLUMN REFER TO
PLAN & SCHEDULE
8" CMU WALL W/ #4
@24" OC GROUT
REINF CELLS SOLID
CONT. BOND BEAM
W/ 2#5 BOTT
R E
F E
R T
O P
L A
N
C BEAML REFER TO PLAN
REFER TO PLAN 1/2".
8" CMU WALL W/ #4
@24" OC GROUT
REINF CELLS SOLID
CONT. BOND BEAM
W/ 2#5 BOTT
FIN FLR
REFER TO PLAN
BEAM REFER
TO PLAN
3/16" ADJUSTABLE
BENT STRAP
ANCHORS @ 32" OC
R E
F E
R T
O P
L A
N
C BEAML
10"
SHAFT WALL
REFER TO ARCH
FIN FLR
REFER TO PLAN
BEAM REFER
TO PLAN
R E
F E
R T
O P
L A
N
C BEAML
9"
SHAFT WALL
REFER TO ARCH
FIN FLR
REFER TO PLAN
BEAM REFER
TO PLAN
CONT. 1/4"x9"x5"
BENT PL. W/
1/2" Ø x12" LG.
HEADED STUDS
@ 18" O.C.
C BEAML
1'-2"
6"
8" CMU WALL W/ #4
@24" OC GROUT
REINF CELLS SOLID
CONT. BOND BEAM
W/ 2#5 BOTT
METAL ROOF
DECK REFER
TO PLAN
BEAM REFER
TO PLAN
3/16" ADJUSTABLE
BENT STRAP
ANCHORS @ 32" OC
TOS EL
REFER TO
PLAN
EL = 857'-4"
CONT 1/4"x6" PLATE
W/ 1/2"Ø HEADED
STUDS @ 24" OC
METAL ROOF DECK
REFER TO PLAN (WELD
DECK TO PLATE)
C COLUMNL
1/4" CAP PLATE
COLUMN
REFER TO
PLAN
BEAM REFER TO PLAN
CJP TOP &
BOTT
BACKUP BAR TYP
STD SHEAR CONN
1" RADIUS, TYP
C BEAML
3/16 4"
3/16 4"
3/8"x3" PLATE CENTERED ON W8's
C O
P E
BEAM REFER TO PLAN
3/16 5"
3/16 5"
TYP 3/16 2"
EA SIDE OF
W8 WEB
(TYP)
C BEAML
BEAM SEE PLAN
PLAN
SEE
E Q
E Q
HEADED STUDS @
CONC. SLAB ONLY
1/4" BENT PL.
METAL DECK,
SEE PLAN
3/16 3-12
TYP
(BENT PLATE DETAIL IS SIMILAR @ ROOF DECK)
1'-0" 8'-9".
BEAM REFER TO PLAN
(2) 3/4"Ø A325 BOLTS
(EA. FLANGE)
1/2" PLATE (TYP)
5/16 3-12
1/2" WEB PLATE
(INTERIOR SIDE ONLY)
~ 1/2"
1/2" PLATE
PLAN
1/2" PLATE
COLUMN REFER TO
PLAN & SCHEDULE
1/4
TYP
A
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:1
P
M
Scale: As indicated
SS301
FRAMING SECTIONS
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
26 148
SCALE: 1 1/2" = 1'-0"
1 DETAIL
SCALE: 3/4" = 1'-0"SS120
2 SECTION
SCALE: 3/4" = 1'-0"SS120
3 SECTION
SCALE: 3/4" = 1'-0"SS110
4 CMU SHAFT SECTION
SCALE: 3/4" = 1'-0"SS120
5 GYP STUD @ STAIR SHAFT SECTION
SCALE: 3/4" = 1'-0"SS110
6 GYP STUD @ MECH SHAFT SECTION
SCALE: 3/4" = 1'-0"SS140
7 CMU ELEV SHAFT ROOF SECTION
SCALE: 1 1/2" = 1'-0"
8 MOMENT CONN @ CANOPY
SS120 SCALE: 1 1/2" = 1'-0"
9 TYP BEAM TO BEAM MOMENT CONN
SS110
SS120
SS130
SCALE: 1" = 1'-0"
TYP. BENT PL. DETAIL
SS140
SS120
SS130
SS120
SS130
SS130
SCALE: 3/4" = 1'-0"SS130
11 SECTION
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
C6x8.2
FRAME
VERIFY LOCATIONS AND SIZES OF ROOF OPNGS,
WITH MECH. CONTRACTOR.
BEAM
BEAM
R E
F E
R T
O P
L A
N
O P
E N
IN
G
M E
C H
A N
IC
A
L C
O N
T R
A C
T O
R
V E
R
IF
Y W
IT
H
MECHANICAL CONTRACTOR
VERIFY WITH
REFER TO PLAN
OPENING
C8x11.5
FRAME
BEAM
BEAM
VERIFY LOCATIONS AND SIZES OF FLOOR OPNGS,
WITH MECH. CONTRACTOR.
MECHANICAL CONTRACTOR
VERIFY WITH
REFER TO PLAN
OPENING
R E
F E
R T
O P
L A
N
O P
E N
IN
G
M E
C H
A N
IC
A
L C
O N
T R
A C
T O
R
V E
R
IF
Y W
IT
H
NOTE:
MEMBER SIZES @ FRAMED OPENINGS ARE
SHOWN AS MINIMUM SIZES. ACTUAL SIZE TO BE
VERIFIED BY EOR AFTER CERTIFIED EQUIPMENT
DRAWINGS ARE RECEIVED AND APPROVED.
1_
1 _ 2
M
IN
3"
3"
1 _ 2
M
IN
FACE OF SUPPORTFACE OF SUPPORT
M
IN.
MIN.
TOP GIRDER FLANGE
STAGGERED
NOTE: PROVIDE ADDITIONAL STUDS AS REQUIRED SUCH
THAT MAXIMUM SPACING DOES NOT EXCEED 36".
NOTES FOR COMPOSITE GIRDER:
1. ALL STUDS SHALL BE EQUALLY SPACED UNLESS NOTED OTHERWISE.
2. WHEN DOUBLE ROW OF STUDS IS REQUIRED TO MEET MINIMUM SPACING
CRITERIA USE A STAGGERED PATTERN IF SPACING PERMITS. SEE MINIMUM
SPACING DETAIL.
±12" ±12"
BEAM
OR COL
BEAM
OR COL
LENGTH
D E
F L E
C T
IO
N
CAMBERED AND/OR NON-CAMBERED
STEEL GIRDER OR BEAM
R E
F E
R T
O P
L A
N
M
IN
IM
U
M S
L A
B T
H K
ADDITIONAL CONCRETE
TO LEVEL SLAB
NOTES:
1. GIRDERS, BEAMS, AND METAL DECK WILL DEFLECT UNDER WEIGHT OF WET CONCRETE. PROVIDE ADDITIONAL CONCRETE
AS REQUIRED TO COMPENSATE FOR THESE DEFECTIONS, AND PRODUCE A LEVEL/FLAT FLOOR AS SPECIFIED AT THE
CORRECT ELEVATIONS.
2. MAXIMUM ANTICIPATED DEFLECTION OF THE STEEL MEMBERS UNDER THE WET WEIGHT OF CONCRETE IS SPAN (L)/240.
REFER TO THE METAL DECK MANUFACTURER'S STANDARD TABLES FOR MAXIMUM ANTICIPATED DEFLECTION OF THE
METAL DECK.
PERPENDICULAR TO METAL DECK PARALLEL TO METAL DECK
METAL DECK
EXTEND REINF THRU BOND BM
CMU PARTITION WALL
METAL DECK
EXTEND REINF THRU BOND BM
CMU PARTITION WALL
G A
P
G A
P
CONT BOND BM
w/ (2) #5 IN FIRST FULL
COURSE BELOW ROOF
DECK, TOP BOND BEAM
SHALL BE CONTINUOUS
ACROSS ALL CONTROL
JOINTS
CONT BOND BM
w/ (2) #5 IN FIRST FULL
COURSE BELOW ROOF
DECK, TOP BOND BEAM
SHALL BE CONTINUOUS
ACROSS ALL CONTROL
JOINTS
PARTIAL COURSE PARTIAL COURSE
2"
2"
CMU PARTITION WALL
BAR JOIST
OR BEAM
PARALLEL TO BEAM OR JOIST
G A
P
1/4 2-8
TYP
L6x3 1/2x5/16 (LLV) W/ 1/2" Ø
EXPANSION ANCHOR LOCATED
3" FROM T/CMU IN LONG
SLOTTED HOLE @ 12" O.C.
PLATE 3/8x3'-0" LONG
FILL VOID WITH
FIRESAFING
1/4 2-8
L6x3 1/2x5/16 (LLV) W/ 1/2" Ø
EXPANSION ANCHOR LOCATED
3" FROM T/CMU IN LONG
SLOTTED HOLE @ 12" O.C.
L6x3 1/2x5/16 (LLV) W/ 1/2" Ø
EXPANSION ANCHOR LOCATED
3" FROM T/CMU IN LONG
SLOTTED HOLE @ 12" O.C.
CONT 1/4" PLATE W/ (2) #10
TEK SCREWS @ 8" OC, EA
SIDE OF WALL. AT LEAST
(1) TEK SCREW SHALL BE
CENTERED IN DECK FLUTE
CONT 1/4" PLATE W/ (2) #10
TEK SCREWS @ 8" OC, EA
SIDE OF WALL. AT LEAST
(1) TEK SCREW SHALL BE
CENTERED IN DECK FLUTE
PL-1/4"
REFER TO KICKER
SCHEDULE THIS
SHEET
BEAM, REFER
TO PLAN
BEAM, REFER
TO PLAN
NOTE: DECK NOT SHOWN FOR CLARITY
PL-1/4"
L4x4x3/8
3/16
3/16
3/16
TYP.
REFER TO KICKER
SCHEDULE THIS SHEET
FINISH
FLOOR
FINISH
FLOOR
L5x3x1/4 (LLV) w/ 2-1/2"Ø x 3" LG
EXP ANCHORS
CENTERED ON
DECK FLUTES
KICKERS
@ 4'-0" OC
L5x3x1/4 (LLV) w/ 2-1/2"Ø x 3" LG
EXP ANCHORS
CENTERED ON
DECK FLUTES
KICKERS
@ 4'-0" OC
3/16
TYP.
3/16
TYP.
LE
N
G
TH
2" M
IN
. W
ELD
1. "L" IS MEASURED PERPENDICULAR OR PARALLEL TO DECK SPAN.
2. FORM OPENINGS TO EXCLUDE CONCRETE AND CUT DECK
AFTER CONCRETE HAS ATTAINED 75% OF DESIGN STRENGTH.
3. ADJACENT PENETRATIONS RESULTING IN LESS THAN 12" CLEAR BETWEEN
PENETRATIONS SHALL BE CONSIDERED AS A SINGLE OPENING.
OVER 30" REFER TO PLANS FOR STEEL FRAMING
24" TO 30" 2-#7 2" FROM T/SLAB
16" TO 24" 2-#6 2" FROM T/SLAB
8" TO 16" 2-#5 2" FROM T/SLAB
REINFORCEMENT
UPTO 8" NONE
CLEAR OPENING SIZE = "L"
OPEN
D E
C K
S P
A N
REINFORCEMENT
REFER TO SCHEDULE
R E
F E
R T
O P
L A
N S
PENETRATION
REINF. SCHEDULE FOR SLAB OPENINGS
NOTES:
LESS THAN 12"
CONSIDERED AS
SINGLE OPENING
30" MAX.
"L" = CLEAR OPENING
M A
X
"L
C
L E
A R
O P
E N
IN
G
PLAN OF REINFORCEMENT
AT SLAB PENETRATIONS
3" 3"
L E
N G
T H
T
Y P
D
E V
E L O
P M
E N
T
A
SS500
SHEAR STUDS
DECK
FINISH SLAB
REINF.
BEAM SIZE
REFER TO PLAN
P L A
N R
E F
E R
T O
C L R
SHEAR STUD
DECK
FINISH SLAB
REINF.
BEAM SIZE
REFER TO PLAN
CLOSURE STRIPS
TYPICAL
#4x5'-0" LONG @ 24" O.C.
@ ALL INTERIOR GIRDERS
P L A
N R
E F
E R
T O
C L R
TYP AT ALL GIRDERS
ON COLUMN GRIDS
3/8" BENT PL.
CHANNEL
FRAME
3/16C ROOF BEAML
BEAM OR
CHANNEL (TYP.)
T/STEEL EL.
REFER TO
PLAN
#4 CONT
4" 2'-3" 4"
3/16 3-12
TYP
P L A
N S
E E
BENT PLATE
3/8"x4"x0'-10" WITH 1/2"Ø x 6" LONG STUD
ANCHORS @ 12" OC
(MIN 2 PER SIDE)
T/CONC EL REFER TO PLAN
3/4" CHAMFER
D A
T E
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
VA ANN ARBOR MEDICAL CENTER CAMPUS
PROJECT #: 015-01361-00
BIDS SUBMISSION_REVISED
C A u to d e s k \R e v it \0
S
S
S O
E .r v t
/9
/2
:5
:1
P
M
Scale: As indicated
SS500
TYPICAL FRAMING DETAILS
GV
506-329CLINICAL & ADMINISTRATIVE
BUILDING
JK04/15/2016
27 148
SCALE: 3/4" = 1'-0"
TYPICAL MECHANICAL ROOF OPENING DETAIL
SCALE: 3/4" = 1'-0"
TYPICAL MECHANICAL FLOOR OPENING DETAIL
SCALE: 3/4" = 1'-0"
TYPICAL STUD DIAGRAM
SCALE: 3/4" = 1'-0"
TYPICAL ELEVATED FLOOR DEFLECTION DETAIL
SCALE: 1" = 1'-0"
TYPICAL MASONRY WALL SUPPORTS
SCALE: 3/4" = 1'-0"
TYP. KICKER ANCHOR DETAILS
SCALE: 3/4" = 1'-0"
TYP. KICKER ANCHOR DETAILS
SCALE: 3/4" = 1'-0"
TYPICAL SLAB PENETRATION DETAIL
SCALE: 3/4" = 1'-0"
TYP. SLAB DETAIL
SCALE: 3/4" = 1'-0"
TYP. SLAB DETAIL
SCALE: 3/4" = 1'-0"
DROP IN FRAME SECTION
SCALE: 3/4" = 1'-0"SS500
A FLOOR OPENING SECTION
ANGLE KICKER SCHEDULE
SIZE LENGTH
L2x2x1/4 5'-0" MAX
L3x3x1/4 5'-1" TO 8'-0"
L4x4x1/4 8'-1" TO 10'-0"
OVER 10'-0" CONSULT WITH ENGINEER
DESIGN DEVELOPMENT SUBMISSION 2 06-10-16
95% CONSTRUCTION DOCUMENTS
SUBMISSION
11-15-16
| 506.329.GI001 - COVER, DRAWING INDEX |
| Sheets |
| AD100 - DEMOLITION PLAN |
| AE100 - BASEMENT FLOOR PLAN |
| AE110 - FIRST FLOOR PLAN |
| AE120 - SECOND FLOOR PLAN |
| AE130 - THIRD FLOOR PLAN |
| AE140 - ROOF PLAN |
| AE150 - BASEMENT REFLECTED CEILING PLAN |
| AE151 - FIRST FLOOR REFLECTED CEILING PLAN |
| AE152 - SECOND FLOOR REFLECTED CEILING PLAN |
| AE153 - THIRD FLOOR REFLECTED CEILING PLAN |
| AE160 - ENLARGED FLOOR PLANS |
| AE200 - EXTERIOR ELEVATIONS |
| AE201 - EXTERIOR ELEVATIONS |
| AE300 - BUILDING SECTIONS |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.