About this file

36C24919R0012 0008 15-584-Electrical_Sheet - TS102 - TECHNOLOGY FIBER ROUTING PLAN.pdf

View the file

Other files

File Type Posted
36C24919R0012-0009000.docx DOCX document
36C24919R0012-0009001.pdf PDF
36C24919R0012-0008002.pdf PDF
36C24919R0012-0008006.pdf PDF
36C24919R0012-0008003.pdf PDF
36C24919R0012-0008001.pdf PDF
36C24919R0012-0008005.pdf PDF
36C24919R0012-0008000.docx DOCX document
36C24919R0012-0007003.pdf PDF
36C24919R0012-0007002.pdf PDF
36C24919R0012-0007001.pdf PDF
36C24919R0012-0007000.docx DOCX document
36C24919R0012-0006000.docx DOCX document
36C24919R0012-0005001.pdf PDF
36C24919R0012-0005000.docx DOCX document
36C24919R0012-0004002.pdf PDF
36C24919R0012-0004000.docx DOCX document
36C24919R0012-0004001.pdf PDF
36C24919R0012-0003002.pdf PDF
36C24919R0012-0003000.docx DOCX document
36C24919R0012-0003001.pdf PDF
36C24919R0012-0002020.pdf PDF
36C24919R0012-0002000.docx DOCX document
36C24919R0012-0002011.pdf PDF
36C24919R0012-0002012.pdf PDF
36C24919R0012-0002004.pdf PDF
36C24919R0012-0002007.pdf PDF
36C24919R0012-0002005.pdf PDF
36C24919R0012-0002015.pdf PDF
36C24919R0012-0002016.pdf PDF
36C24919R0012-0002009.pdf PDF
36C24919R0012-0002001.pdf PDF
36C24919R0012-0002006.pdf PDF
36C24919R0012-0002010.pdf PDF
36C24919R0012-0002002.pdf PDF
36C24919R0012-0002013.pdf PDF
36C24919R0012-0002018.pdf PDF
36C24919R0012-0002017.pdf PDF
36C24919R0012-0002014.pdf PDF
36C24919R0012-0002008.pdf PDF
36C24919R0012-0002019.pdf PDF
36C24919R0012-0002003.pdf PDF
36C24919R0012-0001001.pdf PDF
36C24919R0012-0001000.docx DOCX document
36C24919R0012-020.pdf PDF
36C24919R0012-025.pdf PDF
36C24919R0012-018.pdf PDF
36C24919R0012-035.xlsx XLSX spreadsheet
36C24919R0012-021.pdf PDF
36C24919R0012-033.pdf PDF
Show 40 more

Latest 50 of 67 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FF E: 91 9.5 0

FF E: 91 9.0 0

B S L

30' BSL

B S L

B UI LD ING

# 201

1 0,2 75 S. F.

B UI LD ING

# 202

1 0,2 75 S. F.

B UI LD ING

# 3

(FUTURE P HA SE 2 )

B UI LD ING

# 4

(FUTURE P HA SE 2 )

B UI LD ING

# 5

(FUTURE P HA SE 3 )

B UI LD ING

# 6

(FUTURE P HA SE 3 )

B UI LD ING

# 7

(FUTURE P HA SE 4 )

B UI LD ING

# 8

(FUTURE P HA SE 4 )

T

GEN

S

O2

SC

RE

EN

ED

-IN

SE

C

UR

ED

PO

R

CH

PO

R

CH

O

PT

IO

N

PA

TT

IO

W

TR

EL

LIS

PO

R

CH

SC

RE

EN

ED

-IN

SE

C

UR

ED

PO

R

CH

PO

R

CH

O

PT

IO

N

PA

TT

IO

W

TR

EL

LIS

PO

R

CH

SCREENED-IN

SECURED

PORCH

PORCH

OPTION

PATTIO W/

TRELLIS

PORCH

SCREENED-IN

SECURED

PORCH

PORCHOPTION

PATTIO W/

TRELLIS

PORCH

SCREENED-IN

SECURED

PORCH

PORCHOPTION

PATTIO W/

TRELLIS

PORCH

SC REE NE D-IN

SE C

UR

ED

PO R

C H

PO R

C H

O

P TIO

N

PA TTIO

W

TR ELL IS

PO R

C H

B#22

B#17

PROJECT SITE

C

B#29

44555

HH-9

HH-5

HH-4

HH-3

MH-2

MH-1

T

EXISTING MAIN

TELECOM ROOM 31

T

T

T

B#1

8 10

B#37

B#3B#12

B#16

B#74

B#5

MH-6

HH-7

MH-8

4-12 STRAND FIBER

300 PR TEL.

4-12 STRAND FIBER

300 PR TEL.

4-12 STRAND FIBER

300 PR TEL.

4-12 STRAND FIBER

300 PR TEL.

4-12 STRAND FIBER

300 PR TEL.

4-12 STRAND FIBER

300 PR TEL.

4-12 STRAND FIBER

300 PR TEL.

B#2

FA

T FA C

T FA C

T

FA

C

C

FA

T

T

FA

C

T

FA

C

C

FA

T

T

FA

C

1 1/4" INNER DUCT

15 16

2-14/2 SHIELDED

2-14/2 SHIELDED

2-14/2 SHIELDED

2-14/2 SHIELDED

2-14/2 SHIELDED

2-14/2 SHIELDED

2-14/2 SHIELDED

# SHEET KEY NOTES:

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot th re e ei gh th s in ch o ne fo ot on e ha lf in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot 6" on e in ch o ne fo ot 6" on e an d on e ha lf in ch es o ne fo ot 6" th re e in ch es o ne fo ot

6"

LEXINGTON VAMC, LEESTOWN DIVISION

2250 LEESTOWN ROAD

LEXINGTON, KY 40511

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER: Project Number Scale 15-584

A/E CONSTRUCT CONTINUING

CARE FACILITES, PHASE 1

596-332

SHEET NOTES:

AS INDICATED

FULLY SPRINKLERED

BID DOCUMENTS

E D

C B

A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

# 201 & 202

10/22/18

3/

/2

:2 8:

A

M

TS102

TECHNOLOGY CAMPUS FIBER ROUTING

PLAN

3 9JKM JWB

1" = 100'-0"TS102

1 OVERALL CAMPUS FIBER ROUTING PLAN

1 EXISTING FIRE ALARM FIBER OPTIC PATCH

PANEL TO REMAIN.

2 NEW COMMUNICATIONS HANDHOLE SEE

4/T-502.

3 SEE SHEET TS101 FOR MORE INFORMATION.

4 EXISTING 2-4" CONDUITS TO REMAIN.

5 EXISTING HANDHOLES TO REMAIN.

6 EXISTING SIGNAL/COMMUNICATIONS

MANHOLES WITH EMPTY CONDUIT TO B17

MAIN IT ROOM (13B) TO REMAIN. USE FOR

FIBER AND COPPER. (SEE NOTE 8 BELOW).

7 MAIN IT ROOM 13B IN BUILDING #17. PROVIDE

48 PORT FIBER PATCH PANEL. VERIFY EXACT

LOCATION WITH COR.

8 PROVIDE THE FOLLOWING:

a. 2-12 STRAND OUTDOOR/INDOOR TIGHT

BUFFERED ARMORED INTERLOCKED SINGLE

MODE FIBER (DATA-OS2).

b. 300 PR 22 AWG CAT3 TELEPHONE CABLE

WITH SERVICE ENTRANCE PROTECTION AT

EACH END.

c. 12 STRAND 62.5 MULTI MODE FIBER FOR

FIRE ALARM (OM1).

d. 2-14/2 SHIELDED INTERCOM/ PAGING

OUTDOOR CABLE WITH S.E.P. FOR CLC 201

AND CLC 202.

e. INSTALL CABLES ABOVE IN THE 4" CONDUITS

WITH INNERDUCT. SEE SHEET T-601 FOR MORE

INFO.

f. 12 STRAND 62-5 MULTI MODE FIBER FOR BAS

(OM1).

9 CORE DRILL EXISTING MANHOLE #2 TO

ACCOMMODATE THE NEW 2-4" CONDUIT . SEAL

AROUND CONDUIT.

10 DIRECT BORE 2-4" CONDUIT FORM EXISTING

MANHOLE #8 TO NEW HANDHOLE #9 and #10.

PROVIDE 2-1 1/2", 1-1" INNER DUCT IN EACH

CONDUIT. CALL BEFORE ANY WORK FOR

LOCATION OF ALL UNDERGROUND SYSTEMS.

11 PROVIDE 300 PR 22 AWG OF CAT3 COPPER

OUTDOOR TELEPHONE CABLE FROM BUILDING

1 ALL THE WAY THROUGH THE CABLE TRAY IN

B#1, B#2, AND B#3 THROUGH B#17 TELECOM

ROOM, SUB-BASEMENT OF B#17, IN EXISTING

CONDUIT, THOUGH EXISTING MANHOLES, AND

EXISTING CONDUIT, THROUGH NEW

HANDHOLES, AND NEW CONDUITS TO

BUILDING 201 AND 202, PROVIDE 110 BLOCKS

AT EACH END AND SERVICE ENTRANCE

PROTECTION AND TERMINATE ALL CABLES,

LABEL OR CLC. COORDINATE LOCATION WITH

COR.

12 NEW MANHOLE (6'X7'X7') TO REPLACE

EXISTING HANDHOLE. COORDINATE WITH SITE

WORK. THIS NEW MANHOLE CAN BE USED TO

SPLICE THE NEW 300 PR TELEPHONE CABLE.

13 EXISTING MANHOLE TO REMAIN.

14 EXISTING CONNECT CORRIDOR.

15 PROVIDE 110 BLOCK TO TERMINATE THE NEW

300 PR 22 AWG TELEPHONE CABLE FOR CLC

201 AND 202 LABEL ALL PAIRS.

16 PROVIDE SERVICE ENTRANCE PROTECTION

FOR THE NEW 300 PR 22 AWG TELEPHONE

CABLE FOR CLC 201 AND 202 LABEL ALL

PAIRS.

17 EXISTING 4" CONDUIT WITH 3 INNER DUCT,

WITH FIBER, COPPER AND CONTROL CABLING.

REMOVE 2 INNER DUCT, REMOVE ALL FIBER

CABLING, COPPER CABLING AND CONTROL

CABLING ALL THE WAY TO THE SOURCE. SEE

NOTE 8 FOR NEW CABLING IN THIS EXISTING

CONDUIT.

18 PROVIDE 2-14/2 SHIELDED INTERCOM/PAGING

OUTDOOR CABLE FOR CLC 201 AND CLC 202

TO EXISTING PAGING SYSTEM IN BUILDING 1

ROOM 31. PROVIDE S.E.P. COORDINATE WITH

COR.

19 PROVIDE INTERCOM/PAGING TERMINATION

WITH S.E.P. LABEL CLC 201 AND CLC 202.

20 PROVIDE 12 STRAND FIBER FROM RM 13 IN

BUILDING 17 TO THE EXISTING BAS NETWORK

IN ATTIC OF BUILDING 17.

N

A.

B.

C.

D.

SEE SHEET T-001 FOR ALTERNATE NOTES.

COORDINATE SITE COMMUNICATION CONDUITS

AND MANHOLES WITH CIVIL AND ELECTRICAL

DRAWINGS.

ALL EXISTING CONDITIONS, CONDUITS,

MANHOLES, AND HANDHOLES ARE BASED ON

BEST AVAILABLE INFORMATION AT THE TIME OF

SURVEY AND VISUAL INSPECTION. VERIFY

EXISTING CONDITIONS.

PROVIDE 10' LOOP IN EACH HANDHOLE AND 25'

LOOP IN EACH MANHOLE.

ADDENDUM 4 03/06/19

1 1

Sheets
T-601 - TECHNOLOGY RISERS
TS101 - TECHNOLOGY SITE FIBER ROUTING PLAN
TS102 - TECHNOLOGY CAMPUS FIBER ROUTING PLAN