About this file

36C24919R0012 0002 Drawings - General Info Bid Docs.pdf

View the file

Other files

File Type Posted
36C24919R0012-0009000.docx DOCX document
36C24919R0012-0009001.pdf PDF
36C24919R0012-0008002.pdf PDF
36C24919R0012-0008006.pdf PDF
36C24919R0012-0008003.pdf PDF
36C24919R0012-0008001.pdf PDF
36C24919R0012-0008005.pdf PDF
36C24919R0012-0008004.pdf PDF
36C24919R0012-0008000.docx DOCX document
36C24919R0012-0007003.pdf PDF
36C24919R0012-0007002.pdf PDF
36C24919R0012-0007001.pdf PDF
36C24919R0012-0007000.docx DOCX document
36C24919R0012-0006000.docx DOCX document
36C24919R0012-0005001.pdf PDF
36C24919R0012-0005000.docx DOCX document
36C24919R0012-0004002.pdf PDF
36C24919R0012-0004000.docx DOCX document
36C24919R0012-0004001.pdf PDF
36C24919R0012-0003002.pdf PDF
36C24919R0012-0003000.docx DOCX document
36C24919R0012-0003001.pdf PDF
36C24919R0012-0002020.pdf PDF
36C24919R0012-0002000.docx DOCX document
36C24919R0012-0002011.pdf PDF
36C24919R0012-0002012.pdf PDF
36C24919R0012-0002004.pdf PDF
36C24919R0012-0002007.pdf PDF
36C24919R0012-0002005.pdf PDF
36C24919R0012-0002015.pdf PDF
36C24919R0012-0002016.pdf PDF
36C24919R0012-0002009.pdf PDF
36C24919R0012-0002001.pdf PDF
36C24919R0012-0002010.pdf PDF
36C24919R0012-0002002.pdf PDF
36C24919R0012-0002013.pdf PDF
36C24919R0012-0002018.pdf PDF
36C24919R0012-0002017.pdf PDF
36C24919R0012-0002014.pdf PDF
36C24919R0012-0002008.pdf PDF
36C24919R0012-0002019.pdf PDF
36C24919R0012-0002003.pdf PDF
36C24919R0012-0001001.pdf PDF
36C24919R0012-0001000.docx DOCX document
36C24919R0012-020.pdf PDF
36C24919R0012-025.pdf PDF
36C24919R0012-018.pdf PDF
36C24919R0012-035.xlsx XLSX spreadsheet
36C24919R0012-021.pdf PDF
36C24919R0012-033.pdf PDF
Show 40 more

Latest 50 of 67 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CODE LEGEND

EXIT

SEMI RECESSED FIRE EXTINGUISHER CABINET W/ FIRE

EXTINGUISHER. VERIFY LOCATIONS AND QUANTITIES W/

APPLICABLE CODES, OWNER AND FIRE MARSHAL.

FEC

1 HR FIRE RATED INTERIOR WALL (BEARING) (FIRE

RESISTANT AND SMOKE RESISTANT) (RATING APPLIES TO

PROTECTION OF THE STRUCTURE OF THE WALL ONLY, AND

NOT THE WALL ITSELF)

SMOKE COMPARTMENT (SMOKE BARRIER, 1 HR FIRE

RESISTANT)

1 HR FIRE RATED (FIRE BARRIER)

SUITE OF ROOMS ( ≤ 10,000 SF)

EXTERIOR BEARING WALL (1 HR FIRE RATED)

(EXPOSED TO FIRE FROM INTERIOR SIDE ONLY) (RATING

APPLIES TO PROTECTION OF THE STRUCTURE OF THE

WALL ONLY, AND NOT THE WALL ITSELF)

BRACKET MOUNTED PORTABLE FIRE EXTINGUISHER. VERIFY

LOCATIONS AND QUANTITIES W/ APPLICABLE CODES, OWNER

AND FIRE MARSHAL.

FE

NOTES:

WHERE FIRE BARRIERS OR FIRE WALLS EXTEND ABOVE A CEILING, SUCH WALLS

SHALL BE LABELLED PERMANENTLY AND APPROPRIATELY USING SIGNS OR

STENCILS COMPLYING WITH THE BUILDING CODE.

A SINGLE (1) TYPE 'K' FIRE EXTINGUISHER SHALL BE PROVIDED IN A CABINET OF THE

KITCHEN COOKING AREA.

SMOKE PARTITION (SMOKE RESISTANT)

1 HR FIRE RATED INTERIOR WALL (BEARING) (FIRE

RESISTANT AND SMOKE RESISTANT)

APPLICABLE

BUILDING CODES

Department of Veteran Affairs Fire Protection Design Manual - 7th edition

(FPDM)

2015 Life Safety Code, NFPA 101 (LSC)* VA adopts the National Fire Codes published by NFPA, fire protection design must be based upon the latest editions of the NFC at the Date of Award of the contract to the Architectural/Engineering firm.

2015 International Building Code - fire protection features not addressed by the NFC or FPDM must be designed to comply with IBC *Code referenced unless otherwise noted.

ALLOWABLE HEIGHT AND AREA PER BUILDING

OCCUPANCY

CLASSIFICATION

Healthcare, Nursing Home

CONSTRUCTION TYPE Type V(111); combustible, 1-hour rated

SPRINKLER SYSTEM Equipped throughout with an automatic sprinkler system in accordance with 903.3.1.1

LIFE SAFETY / BUILDING CODE SUMMARY

TRAVEL DISTANCE

RESTRICTIONS

(NFPA 101, 2015 ED.)

• Dead-end Corridor Limit: 30ft

• Common Path of Travel: 100ft

• Travel Distance to Exits: 200ft from room door to exit access or exit

• Travel Distance from Room: 50ft

(18.2.6.2.1, 18.2.6.2.3, 18.2.5.3)

1 story; 50 ft Area not regulated by NFPA 101

1 story; 36 ft 11,099 sf

ACTUAL HEIGHT AND

BUILDING AREA

TABULAR VALUES:

MISCELLANEOUS

REQUIREMENTS

• Two accessible exits required (18.2.4.2)

• An exit capacity of 0.2 in/occupant must be provided for horizontal travel such as doors, ramps, etc. in I-2 Occupancies. (18.2.3.2)

BUILDING USE (2) Buildings in Project Scope. These facilities will be used for the long term care and rehabilitation of residents who are otherwise incapable of caring for themselves. 24 Hour Care will be provided.

FIRE RESISTANCE

RATING REQ'TS FOR

BUILDING ELEMENTS

Structural Frame 1 HR

Bearing Walls Exterior 1 HR Interior 1 HR

Non Bearing Walls Exterior 0 HR Interior 0 HR

Floor Construction N/A - Slab on Grade

Roof Construction 1 HR

• Private Parking Garage must be separated from the home by a 1-hour fire barrier with a 45-minute door (406.6.4, Table 508.4, IBC)

• 1-hour smoke barriers are required to divide every story used by inpatients for sleeping or treatment into not less than two smoke compartments. Each smoke compartment must not exceed 22,500

sq. ft. The travel distance from any point to reach a door in the smoke barrier must not exceed 200 feet. (18.3.7.1, 18.3.7.3; 2.10, FPDM)

• Not less than 30 net sq. ft. per bed or litter patient must be provided on each side of the smoke barrier. Not less than 6 sq. ft. per occupant required for smoke compartments on stories not housing bed or litter patients must be provided on each side of the smoke barrier.

(18.3.7.5.1)

• Doors in a smoke barrier must be substantial doors such as 1 3/4 in thick solid-bonded wood core doors or be 20 minute rated assemblies. Doors must be self or automatic closing. (18.3.7.6, 18.3.7.8, 18.3.7.9)

• At least two exits must be accessible from each smoke compartment.

Means of egress may pass through adjacent zones as long as they do not return through the zone of fire origin. (18.2.4.4)

• Fire dampers are required at duct penetrations of fire walls.

• Smoke dampers are not required at duct penetrations of shafts, fire barriers, or fire walls. Smoke dampers are not required in duct penetrations of smoke barriers in fully ducted heating, ventilating, and air conditioning systems. Smoke dampers are not required where duct openings are limited to a single smoke compartment and the ducts are of steel construction. Ceiling radiation dampers required for membrane penetrations of 1-hour rated ceiling assemblies. (8.5.5.3 & 18.3.7.3)

• Corridors in nursing homes are permitted to be a minimum of 6 feet in clear and unobstructed width in smoke compartments not housing more than 30 patients. Corridors in adjunct areas not intended for the housing, treatment, or use of inpatients must not be less than 44 inches in clear and unobstructed width. (18.2.3.4(1)&(7))

• Corridor walls must limit the transfer of smoke. Walls are permitted to terminate at the ceiling where the ceiling is constructed to limit the transfer of smoke. Corridor doors must be provided with positive latching hardware. Doors to toilet rooms, shower rooms, bathrooms, sink closets, and similar auxiliary spaces that do not contain flammable or combustible materials are not required to latch or resist the passage of smoke. (18.3.6.2, 18.3.6.3, 18.3.6.3(3), 18.3.6.3.6)

• Dead end corridors must not exceed 30 feet. (18.2.5.2)

REQ'D SEPARATIONS

FE

FE

FE

FE

FE

462 SFS

STORAGE

300 2

268 SFI2

BEDROOM

RESIDENT A-2

120 3

233 SFI2

BEDROOM

RESIDENT A-1

120 2

242 SFI2

BEDROOM

RESIDENT A-3

120 2

243 SFI2

BEDROOM

RESIDENT A-4

120 2

284 SFI2

SPECIAL CARE

BEDROOM B-1

120 3

266 SFI2

BEDROOM

RESIDENT A-7

120 3

231 SFI2

BEDROOM

RESIDENT A-8

120 2

240 SFI2

BEDROOM

RESIDENT A-6

120 2

241 SFI2

BEDROOM

RESIDENT A-5

120 2

278 SFI2

BEDROOM

RESIDENT A-9

120 3

148 SFI2

BATHING

240 1

88 SF

VEST.

192 SFA

QUIET

15 14

62 SFS

PANTRY

300 1

528 SFA

KITCHEN

15 35

588 SFA

LIVING

15 39

350 SFA

DINING

15 24

12 SFS

OX

300 1

160 SFS

COOLER

300 1

307 SF

CORRIDOR

409 SF

CORRIDOR

414 SF

CORRIDOR

753 SF

CORRIDOR

227 SFM

ELEC.

300 1

192 SFL

LOUNGE

50 4

81 SFI2

BATH A-1

120 1

80 SFI2

BATH A-8

120 1

83 SFI2

BATH A-2

120 1

83 SFI2

BATH A-3

120 1

83 SFI2

BATH A-4

120 1

82 SFI2

BATH A-5

120 1

82 SFI2

BATH A-6

120 1

82 SFI2

BATH A-7

120 1

S

F I2

B A

T H

B -1

S

F I2

B A

T H

B -2

11 SFS

OX

300 1

79 SF

PUBLIC

TOILET

S

F S

S T

O R

A G

E

84 SFS

EQUIPMENT

300 1

68 SFS

HAC

300 1

221 SFB

CLINICAL

100 3

S

F S

L A

U N

D R

Y

77 SFS

CLEAN LINEN

300 1

S

F S

S O

IL

E

D H

O L D

IN

G

94 SFS

SUPPLIES

300 1

10 SFS

PANTRY

300 1

S

F M

B

IO

M E

D

403 SFM

MECH

300 1

S

F M

O

IT

29 SFS

STORAGE

300 1

41 SFS

MORGUE

300 1

96'-4" TRAVEL

107'-10" TRAVEL

SMOKE

COMPARTMENT 1:

6,637SF

SMOKE

COMPARTMENT 2:

4,461SF

30 SFS

MED GAS

300 1

WIDTH MAX.

DOOR

UTILIZED

3'-8" 220

WIDTH MAX.

DOOR

UTILIZED

3'-8" 220

WIDTH MAX.

DOOR

UTILIZED

111B

3'-8" 220

WIDTH MAX.

DOOR

UTILIZED

112A

7'-6" 440

WIDTH MAX.

DOOR

UTILIZED

7'-6" 440

WIDTH MAX.

DOOR

UTILIZED

114B

3'-0" 180

FEC

FEC

PATH OF TRAVEL

8' - 0" CLEAR

FE

EGRESS LEGEND

ROOM

X

# SF

ROOM NAME

ROOM AREA

NUMBER OF

EXITS REQ'D

OCCUPANCY

TYPE

AREA PER

OCCUPANT

PER CODE

ACTUAL NUMBER

OF OCCUPANTS

IN ROOM

XX'-0" TRAVEL

MAX. TRAVEL

DISTANCE TO

EXIT

DOOR

DOOR #

WIDTH MAX

3'-0" 240

UTILIZED 72

DOOR WIDTH

UTILIZED

OCCUPANT LOAD

MAX OCC.

LOAD

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t

# 201

LEXINGTON VAMC, LEESTOWN DIVISION

2250 LEESTOWN ROAD

LEXINGTON, KY 40511

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER:

Project Number Scale

15-584

CONSTRUCT CONTINUING

CARE FACILITES - PHASE 1

596-332AS INDICATED

FULLY SPRINKLERED

BID DOCUMENTS

E D

C B

A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

SEPTEMBER 16, 2018

/1

/2

:3

:2

P

M

GI111

BUILDING 201 - FIRST FLOOR LIFE

SAFETY PLAN

3 5DLW VFS

1/8" = 1'-0"

GI111

1 FIRST FLOOR LIFE SAFETY PLAN

NOTES:

1. EXTERIOR CONTENT IS SHOWN FOR REFERENCE

ONLY. REF. TO EXTERIOR ARCHITECTURE

SHEETS FOR FURTHER INFORMATION.

2. THIS SHEET SHALL ALWAYS BE VIEWED IN

COLOR, NOT BLACK AND WHITE.

FE

FE

FE

FE

FE

464 SFS

STORAGE

300 2

268 SFI2

BEDROOM

RESIDENT A-2

120 3

234 SFI2

BEDROOM

RESIDENT A-1

120 2

242 SFI2

BEDROOM

RESIDENT A-3

120 2

243 SFI2

BEDROOM

RESIDENT A-4

120 2

284 SFI2

SPECIAL CARE

BEDROOM B-1

120 3

266 SFI2

BEDROOM

RESIDENT A-7

120 3

232 SFI2

BEDROOM

RESIDENT A-8

120 2

240 SFI2

BEDROOM

RESIDENT A-6

120 2

241 SFI2

BEDROOM

RESIDENT A-5

120 2

279 SFI2

SPECIAL CARE

BEDROOM B-2

120 3

148 SFI2

BATHING

240 1

88 SF

VEST.

192 SFA

QUIET

15 14

62 SFS

PANTRY

300 1529 SFA

KITCHEN

15 35

588 SFA

LIVING

15 39

350 SFA

DINING

15 24

12 SFS

OX

300 1

194 SFI2

SALON

240 1307 SF

CORRIDOR

409 SF

CORRIDOR

414 SF

CORRIDOR

752 SF

CORRIDOR

227 SFM

ELEC.

300 1

192 SFL

LOUNGE

50 4

81 SFI2

BATH A-1

120 1

80 SFI2

BATH A-8

120 1

83 SFI2

BATH A-2

120 1

83 SFI2

BATH A-3

120 1

83 SFI2

BATH A-4

120 1

82 SFI2

BATH A-5

120 1

82 SFI2

BATH A-6

120 1

82 SFI2

BATH A-7

120 1

S

F I2

B A

T H

B -1

S

F I2

B A

T H

B -2

11 SFS

OX

300 1

77 SF

PUBLIC

TOILET

S

F S

S T

O R

A G

E

84 SFS

EQUIPMENT

300 1

68 SFS

HAC

300 1

221 SFB

CLINICAL

100 3

S

F S

L A

U N

D R

Y

77 SFS

CLEAN LINEN

300 1

S

F S

S O

IL

E

D H

O L D

IN

G

94 SFS

SUPPLIES

300 1

10 SFS

PANTRY

300 1

S

F M

B

IO

M E

D

403 SFM

MECH

300 1

S

F M

O

IT

29 SFS

STORAGE

300 1

S

F S

S T

O R

A G

E

FEC

FEC

96'-4" TRAVEL

107'-10" TRAVEL

SMOKE

COMPARTMENT 1:

6,637SF

SMOKE

COMPARTMENT 2:

4,461SF

WIDTH MAX.

DOOR

UTILIZED

114B

3'-0" 180

WIDTH MAX.

DOOR

UTILIZED

7'-6" 440

WIDTH MAX.

DOOR

UTILIZED

3'-8" 220

WIDTH MAX.

DOOR

UTILIZED

3'-8" 220

WIDTH MAX.

DOOR

UTILIZED

7'-6" 440

PATH OF TRAVEL

8' - 0" CLEAR

WIDTH MAX.

DOOR

UTILIZED

111B

3'-8" 220

FE

APPLICABLE

BUILDING CODES

Department of Veteran Affairs Fire Protection Design Manual - 7th edition

(FPDM)

2015 Life Safety Code, NFPA 101 (LSC)* VA adopts the National Fire Codes published by NFPA, fire protection design must be based upon the latest editions of the NFC at the Date of Award of the contract to the Architectural/Engineering firm.

2015 International Building Code - fire protection features not addressed by the NFC or FPDM must be designed to comply with IBC *Code referenced unless otherwise noted.

ALLOWABLE HEIGHT AND AREA PER BUILDING

OCCUPANCY

CLASSIFICATION

Healthcare, Nursing Home

CONSTRUCTION TYPE Type V(111); combustible, 1-hour rated

SPRINKLER SYSTEM Equipped throughout with an automatic sprinkler system in accordance with 903.3.1.1

LIFE SAFETY / BUILDING CODE SUMMARY

TRAVEL DISTANCE

RESTRICTIONS

(NFPA 101, 2015 ED.)

• Dead-end Corridor Limit: 30ft

• Common Path of Travel: 100ft

• Travel Distance to Exits: 200ft from room door to exit access or exit

• Travel Distance from Room: 50ft

(18.2.6.2.1, 18.2.6.2.3, 18.2.5.3)

1 story; 50 ft Area not regulated by NFPA 101

1 story; 36 ft 11,099 sf

ACTUAL HEIGHT AND

BUILDING AREA

TABULAR VALUES:

MISCELLANEOUS

REQUIREMENTS

• Two accessible exits required (18.2.4.2)

• An exit capacity of 0.2 in/occupant must be provided for horizontal travel such as doors, ramps, etc. in I-2 Occupancies. (18.2.3.2)

BUILDING USE (2) Buildings in Project Scope. These facilities will be used for the long term care and rehabilitation of residents who are otherwise incapable of caring for themselves. 24 Hour Care will be provided.

FIRE RESISTANCE

RATING REQ'TS FOR

BUILDING ELEMENTS

Structural Frame 1 HR

Bearing Walls Exterior 1 HR Interior 1 HR

Non Bearing Walls Exterior 0 HR Interior 0 HR

Floor Construction N/A - Slab on Grade

Roof Construction 1 HR

• Private Parking Garage must be separated from the home by a 1-hour fire barrier with a 45-minute door (406.6.4, Table 508.4, IBC)

• 1-hour smoke barriers are required to divide every story used by inpatients for sleeping or treatment into not less than two smoke compartments. Each smoke compartment must not exceed 22,500

sq. ft. The travel distance from any point to reach a door in the smoke barrier must not exceed 200 feet. (18.3.7.1, 18.3.7.3; 2.10, FPDM)

• Not less than 30 net sq. ft. per bed or litter patient must be provided on each side of the smoke barrier. Not less than 6 sq. ft. per occupant required for smoke compartments on stories not housing bed or litter patients must be provided on each side of the smoke barrier.

(18.3.7.5.1)

• Doors in a smoke barrier must be substantial doors such as 1 3/4 in thick solid-bonded wood core doors or be 20 minute rated assemblies. Doors must be self or automatic closing. (18.3.7.6, 18.3.7.8, 18.3.7.9)

• At least two exits must be accessible from each smoke compartment.

Means of egress may pass through adjacent zones as long as they do not return through the zone of fire origin. (18.2.4.4)

• Fire dampers are required at duct penetrations of fire walls.

• Smoke dampers are not required at duct penetrations of shafts, fire barriers, or fire walls. Smoke dampers are not required in duct penetrations of smoke barriers in fully ducted heating, ventilating, and air conditioning systems. Smoke dampers are not required where duct openings are limited to a single smoke compartment and the ducts are of steel construction. Ceiling radiation dampers required for membrane penetrations of 1-hour rated ceiling assemblies. (8.5.5.3 & 18.3.7.3)

• Corridors in nursing homes are permitted to be a minimum of 6 feet in clear and unobstructed width in smoke compartments not housing more than 30 patients. Corridors in adjunct areas not intended for the housing, treatment, or use of inpatients must not be less than 44 inches in clear and unobstructed width. (18.2.3.4(1)&(7))

• Corridor walls must limit the transfer of smoke. Walls are permitted to terminate at the ceiling where the ceiling is constructed to limit the transfer of smoke. Corridor doors must be provided with positive latching hardware. Doors to toilet rooms, shower rooms, bathrooms, sink closets, and similar auxiliary spaces that do not contain flammable or combustible materials are not required to latch or resist the passage of smoke. (18.3.6.2, 18.3.6.3, 18.3.6.3(3), 18.3.6.3.6)

• Dead end corridors must not exceed 30 feet. (18.2.5.2)

REQ'D SEPARATIONS

CODE LEGEND

EXIT

SEMI RECESSED FIRE EXTINGUISHER CABINET W/ FIRE

EXTINGUISHER. VERIFY LOCATIONS AND QUANTITIES W/

APPLICABLE CODES, OWNER AND FIRE MARSHAL.

FEC

1 HR FIRE RATED INTERIOR WALL (BEARING) (FIRE

RESISTANT AND SMOKE RESISTANT) (RATING APPLIES TO

PROTECTION OF THE STRUCTURE OF THE WALL ONLY, AND

NOT THE WALL ITSELF)

SMOKE COMPARTMENT (SMOKE BARRIER, 1 HR FIRE

RESISTANT)

1 HR FIRE RATED (FIRE BARRIER)

SUITE OF ROOMS ( ≤ 10,000 SF)

EXTERIOR BEARING WALL (1 HR FIRE RATED)

(EXPOSED TO FIRE FROM INTERIOR SIDE ONLY) (RATING

APPLIES TO PROTECTION OF THE STRUCTURE OF THE

WALL ONLY, AND NOT THE WALL ITSELF)

BRACKET MOUNTED PORTABLE FIRE EXTINGUISHER. VERIFY

LOCATIONS AND QUANTITIES W/ APPLICABLE CODES, OWNER

AND FIRE MARSHAL.

FE

NOTES:

WHERE FIRE BARRIERS OR FIRE WALLS EXTEND ABOVE A CEILING, SUCH WALLS

SHALL BE LABELLED PERMANENTLY AND APPROPRIATELY USING SIGNS OR

STENCILS COMPLYING WITH THE BUILDING CODE.

A SINGLE (1) TYPE 'K' FIRE EXTINGUISHER SHALL BE PROVIDED IN A CABINET OF THE

KITCHEN COOKING AREA.

SMOKE PARTITION (SMOKE RESISTANT)

1 HR FIRE RATED INTERIOR WALL (BEARING) (FIRE

RESISTANT AND SMOKE RESISTANT)

EGRESS LEGEND

ROOM

X

# SF

ROOM NAME

ROOM AREA

NUMBER OF

EXITS REQ'D

OCCUPANCY

TYPE

AREA PER

OCCUPANT

PER CODE

ACTUAL NUMBER

OF OCCUPANTS

IN ROOM

XX'-0" TRAVEL

MAX. TRAVEL

DISTANCE TO

EXIT

DOOR

DOOR #

WIDTH MAX

3'-0" 240

UTILIZED 72

DOOR WIDTH

UTILIZED

OCCUPANT LOAD

MAX OCC.

LOAD

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t

LEXINGTON VAMC, LEESTOWN DIVISION

2250 LEESTOWN ROAD

LEXINGTON, KY 40511

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER:

Project Number Scale

15-584

CONSTRUCT CONTINUING

CARE FACILITES - PHASE 1

596-332AS INDICATED

FULLY SPRINKLERED

BID DOCUMENTS

E D

C B

A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

SEPTEMBER 16, 2018

# 202

/1

/2

:3

:3

P

M

GI121

BUILDING 202 - FIRST FLOOR LIFE

SAFETY PLAN

4 5DLW VFS

1/8" = 1'-0"

GI121

1 FIRST FLOOR LIFE SAFETY PLAN

NOTES:

1. EXTERIOR CONTENT IS SHOWN FOR REFERENCE

ONLY. REF. TO EXTERIOR ARCHITECTURE

SHEETS FOR FURTHER INFORMATION.

2. THIS SHEET SHALL ALWAYS BE VIEWED IN

COLOR, NOT BLACK AND WHITE.

2.12.22.4

2.A

2.B

2.C

2.D

2.3

2.E

2.F

1.1 1.2 1.3 1.4

1.A

1.B

1.C

1.D

1.E

1.F

RATED ASSEMBLY LEGEND

1-HR RATED FLOOR (UL #L511, SYSTEM NO. 5)

1-HR RATED ROOF (UL #P522)

1-HR RATED ROOF (UL #P545)

1-HR RATED ROOF (UL #P522) W/

(1) LAYER 1/2" OSB SHEATHING BETWEEN

RESILIENT CHANNELS AND GYPSUM BOARD

1-HR RATED ROOF (GA #RC2601) @ DORMERS

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t

LEXINGTON VAMC, LEESTOWN DIVISION

2250 LEESTOWN ROAD

LEXINGTON, KY 40511

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER:

Project Number Scale

15-584

CONSTRUCT CONTINUING

CARE FACILITES - PHASE 1

596-332AS INDICATED

FULLY SPRINKLERED

BID DOCUMENTS

E D

C B

A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

SEPTEMBER 16, 2018

# 201 & 202

/1

/2

:3

:4

P

M

GI131

RATED ASSEMBLIES PLANS

5 5DLW VFS

1/8" = 1'-0"

GI131

2 FIRST FLOOR RATED ASSEMBLY PLAN - BUILDING 202

1/8" = 1'-0"

GI131

1 FIRST FLOOR RATED ASSEMBLY PLAN - BUILDING 201

NN

NOTES:

1. EXTERIOR CONTENT IS SHOWN FOR

REFERENCE ONLY. REF. TO EXTERIOR

ARCHITECTURE SHEETS FOR FURTHER

INFORMATION.

01-General Info Bid Docs
01.5-General Info Bid Docs

File details come from the government source that posted it.