CODE LEGEND
EXIT
SEMI RECESSED FIRE EXTINGUISHER CABINET W/ FIRE
EXTINGUISHER. VERIFY LOCATIONS AND QUANTITIES W/
APPLICABLE CODES, OWNER AND FIRE MARSHAL.
FEC
1 HR FIRE RATED INTERIOR WALL (BEARING) (FIRE
RESISTANT AND SMOKE RESISTANT) (RATING APPLIES TO
PROTECTION OF THE STRUCTURE OF THE WALL ONLY, AND
NOT THE WALL ITSELF)
SMOKE COMPARTMENT (SMOKE BARRIER, 1 HR FIRE
RESISTANT)
1 HR FIRE RATED (FIRE BARRIER)
SUITE OF ROOMS ( ≤ 10,000 SF)
EXTERIOR BEARING WALL (1 HR FIRE RATED)
(EXPOSED TO FIRE FROM INTERIOR SIDE ONLY) (RATING
APPLIES TO PROTECTION OF THE STRUCTURE OF THE
WALL ONLY, AND NOT THE WALL ITSELF)
BRACKET MOUNTED PORTABLE FIRE EXTINGUISHER. VERIFY
LOCATIONS AND QUANTITIES W/ APPLICABLE CODES, OWNER
AND FIRE MARSHAL.
FE
NOTES:
WHERE FIRE BARRIERS OR FIRE WALLS EXTEND ABOVE A CEILING, SUCH WALLS
SHALL BE LABELLED PERMANENTLY AND APPROPRIATELY USING SIGNS OR
STENCILS COMPLYING WITH THE BUILDING CODE.
A SINGLE (1) TYPE 'K' FIRE EXTINGUISHER SHALL BE PROVIDED IN A CABINET OF THE
KITCHEN COOKING AREA.
SMOKE PARTITION (SMOKE RESISTANT)
1 HR FIRE RATED INTERIOR WALL (BEARING) (FIRE
RESISTANT AND SMOKE RESISTANT)
APPLICABLE
BUILDING CODES
Department of Veteran Affairs Fire Protection Design Manual - 7th edition
(FPDM)
2015 Life Safety Code, NFPA 101 (LSC)* VA adopts the National Fire Codes published by NFPA, fire protection design must be based upon the latest editions of the NFC at the Date of Award of the contract to the Architectural/Engineering firm.
2015 International Building Code - fire protection features not addressed by the NFC or FPDM must be designed to comply with IBC *Code referenced unless otherwise noted.
ALLOWABLE HEIGHT AND AREA PER BUILDING
OCCUPANCY
CLASSIFICATION
Healthcare, Nursing Home
CONSTRUCTION TYPE Type V(111); combustible, 1-hour rated
SPRINKLER SYSTEM Equipped throughout with an automatic sprinkler system in accordance with 903.3.1.1
LIFE SAFETY / BUILDING CODE SUMMARY
TRAVEL DISTANCE
RESTRICTIONS
(NFPA 101, 2015 ED.)
• Dead-end Corridor Limit: 30ft
• Common Path of Travel: 100ft
• Travel Distance to Exits: 200ft from room door to exit access or exit
• Travel Distance from Room: 50ft
(18.2.6.2.1, 18.2.6.2.3, 18.2.5.3)
1 story; 50 ft Area not regulated by NFPA 101
1 story; 36 ft 11,099 sf
ACTUAL HEIGHT AND
BUILDING AREA
TABULAR VALUES:
MISCELLANEOUS
REQUIREMENTS
• Two accessible exits required (18.2.4.2)
• An exit capacity of 0.2 in/occupant must be provided for horizontal travel such as doors, ramps, etc. in I-2 Occupancies. (18.2.3.2)
BUILDING USE (2) Buildings in Project Scope. These facilities will be used for the long term care and rehabilitation of residents who are otherwise incapable of caring for themselves. 24 Hour Care will be provided.
FIRE RESISTANCE
RATING REQ'TS FOR
BUILDING ELEMENTS
Structural Frame 1 HR
Bearing Walls Exterior 1 HR Interior 1 HR
Non Bearing Walls Exterior 0 HR Interior 0 HR
Floor Construction N/A - Slab on Grade
Roof Construction 1 HR
• Private Parking Garage must be separated from the home by a 1-hour fire barrier with a 45-minute door (406.6.4, Table 508.4, IBC)
• 1-hour smoke barriers are required to divide every story used by inpatients for sleeping or treatment into not less than two smoke compartments. Each smoke compartment must not exceed 22,500
sq. ft. The travel distance from any point to reach a door in the smoke barrier must not exceed 200 feet. (18.3.7.1, 18.3.7.3; 2.10, FPDM)
• Not less than 30 net sq. ft. per bed or litter patient must be provided on each side of the smoke barrier. Not less than 6 sq. ft. per occupant required for smoke compartments on stories not housing bed or litter patients must be provided on each side of the smoke barrier.
(18.3.7.5.1)
• Doors in a smoke barrier must be substantial doors such as 1 3/4 in thick solid-bonded wood core doors or be 20 minute rated assemblies. Doors must be self or automatic closing. (18.3.7.6, 18.3.7.8, 18.3.7.9)
• At least two exits must be accessible from each smoke compartment.
Means of egress may pass through adjacent zones as long as they do not return through the zone of fire origin. (18.2.4.4)
• Fire dampers are required at duct penetrations of fire walls.
• Smoke dampers are not required at duct penetrations of shafts, fire barriers, or fire walls. Smoke dampers are not required in duct penetrations of smoke barriers in fully ducted heating, ventilating, and air conditioning systems. Smoke dampers are not required where duct openings are limited to a single smoke compartment and the ducts are of steel construction. Ceiling radiation dampers required for membrane penetrations of 1-hour rated ceiling assemblies. (8.5.5.3 & 18.3.7.3)
• Corridors in nursing homes are permitted to be a minimum of 6 feet in clear and unobstructed width in smoke compartments not housing more than 30 patients. Corridors in adjunct areas not intended for the housing, treatment, or use of inpatients must not be less than 44 inches in clear and unobstructed width. (18.2.3.4(1)&(7))
• Corridor walls must limit the transfer of smoke. Walls are permitted to terminate at the ceiling where the ceiling is constructed to limit the transfer of smoke. Corridor doors must be provided with positive latching hardware. Doors to toilet rooms, shower rooms, bathrooms, sink closets, and similar auxiliary spaces that do not contain flammable or combustible materials are not required to latch or resist the passage of smoke. (18.3.6.2, 18.3.6.3, 18.3.6.3(3), 18.3.6.3.6)
• Dead end corridors must not exceed 30 feet. (18.2.5.2)
REQ'D SEPARATIONS
FE
FE
FE
FE
FE
462 SFS
STORAGE
300 2
268 SFI2
BEDROOM
RESIDENT A-2
120 3
233 SFI2
BEDROOM
RESIDENT A-1
120 2
242 SFI2
BEDROOM
RESIDENT A-3
120 2
243 SFI2
BEDROOM
RESIDENT A-4
120 2
284 SFI2
SPECIAL CARE
BEDROOM B-1
120 3
266 SFI2
BEDROOM
RESIDENT A-7
120 3
231 SFI2
BEDROOM
RESIDENT A-8
120 2
240 SFI2
BEDROOM
RESIDENT A-6
120 2
241 SFI2
BEDROOM
RESIDENT A-5
120 2
278 SFI2
BEDROOM
RESIDENT A-9
120 3
148 SFI2
BATHING
240 1
88 SF
VEST.
192 SFA
QUIET
15 14
62 SFS
PANTRY
300 1
528 SFA
KITCHEN
15 35
588 SFA
LIVING
15 39
350 SFA
DINING
15 24
12 SFS
OX
300 1
160 SFS
COOLER
300 1
307 SF
CORRIDOR
409 SF
CORRIDOR
414 SF
CORRIDOR
753 SF
CORRIDOR
227 SFM
ELEC.
300 1
192 SFL
LOUNGE
50 4
81 SFI2
BATH A-1
120 1
80 SFI2
BATH A-8
120 1
83 SFI2
BATH A-2
120 1
83 SFI2
BATH A-3
120 1
83 SFI2
BATH A-4
120 1
82 SFI2
BATH A-5
120 1
82 SFI2
BATH A-6
120 1
82 SFI2
BATH A-7
120 1
S
F I2
B A
T H
B -1
S
F I2
B A
T H
B -2
11 SFS
OX
300 1
79 SF
PUBLIC
TOILET
S
F S
S T
O R
A G
E
84 SFS
EQUIPMENT
300 1
68 SFS
HAC
300 1
221 SFB
CLINICAL
100 3
S
F S
L A
U N
D R
Y
77 SFS
CLEAN LINEN
300 1
S
F S
S O
IL
E
D H
O L D
IN
G
94 SFS
SUPPLIES
300 1
10 SFS
PANTRY
300 1
S
F M
B
IO
M E
D
403 SFM
MECH
300 1
S
F M
O
IT
29 SFS
STORAGE
300 1
41 SFS
MORGUE
300 1
96'-4" TRAVEL
107'-10" TRAVEL
SMOKE
COMPARTMENT 1:
6,637SF
SMOKE
COMPARTMENT 2:
4,461SF
30 SFS
MED GAS
300 1
WIDTH MAX.
DOOR
UTILIZED
3'-8" 220
WIDTH MAX.
DOOR
UTILIZED
3'-8" 220
WIDTH MAX.
DOOR
UTILIZED
111B
3'-8" 220
WIDTH MAX.
DOOR
UTILIZED
112A
7'-6" 440
WIDTH MAX.
DOOR
UTILIZED
7'-6" 440
WIDTH MAX.
DOOR
UTILIZED
114B
3'-0" 180
FEC
FEC
PATH OF TRAVEL
8' - 0" CLEAR
FE
EGRESS LEGEND
ROOM
X
# SF
ROOM NAME
ROOM AREA
NUMBER OF
EXITS REQ'D
OCCUPANCY
TYPE
AREA PER
OCCUPANT
PER CODE
ACTUAL NUMBER
OF OCCUPANTS
IN ROOM
XX'-0" TRAVEL
MAX. TRAVEL
DISTANCE TO
EXIT
DOOR
DOOR #
WIDTH MAX
3'-0" 240
UTILIZED 72
DOOR WIDTH
UTILIZED
OCCUPANT LOAD
MAX OCC.
LOAD
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
# 201
LEXINGTON VAMC, LEESTOWN DIVISION
2250 LEESTOWN ROAD
LEXINGTON, KY 40511
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
Project Number Scale
15-584
CONSTRUCT CONTINUING
CARE FACILITES - PHASE 1
596-332AS INDICATED
FULLY SPRINKLERED
BID DOCUMENTS
E D
C B
A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
SEPTEMBER 16, 2018
/1
/2
:3
:2
P
M
GI111
BUILDING 201 - FIRST FLOOR LIFE
SAFETY PLAN
3 5DLW VFS
1/8" = 1'-0"
GI111
1 FIRST FLOOR LIFE SAFETY PLAN
NOTES:
1. EXTERIOR CONTENT IS SHOWN FOR REFERENCE
ONLY. REF. TO EXTERIOR ARCHITECTURE
SHEETS FOR FURTHER INFORMATION.
2. THIS SHEET SHALL ALWAYS BE VIEWED IN
COLOR, NOT BLACK AND WHITE.
FE
FE
FE
FE
FE
464 SFS
STORAGE
300 2
268 SFI2
BEDROOM
RESIDENT A-2
120 3
234 SFI2
BEDROOM
RESIDENT A-1
120 2
242 SFI2
BEDROOM
RESIDENT A-3
120 2
243 SFI2
BEDROOM
RESIDENT A-4
120 2
284 SFI2
SPECIAL CARE
BEDROOM B-1
120 3
266 SFI2
BEDROOM
RESIDENT A-7
120 3
232 SFI2
BEDROOM
RESIDENT A-8
120 2
240 SFI2
BEDROOM
RESIDENT A-6
120 2
241 SFI2
BEDROOM
RESIDENT A-5
120 2
279 SFI2
SPECIAL CARE
BEDROOM B-2
120 3
148 SFI2
BATHING
240 1
88 SF
VEST.
192 SFA
QUIET
15 14
62 SFS
PANTRY
300 1529 SFA
KITCHEN
15 35
588 SFA
LIVING
15 39
350 SFA
DINING
15 24
12 SFS
OX
300 1
194 SFI2
SALON
240 1307 SF
CORRIDOR
409 SF
CORRIDOR
414 SF
CORRIDOR
752 SF
CORRIDOR
227 SFM
ELEC.
300 1
192 SFL
LOUNGE
50 4
81 SFI2
BATH A-1
120 1
80 SFI2
BATH A-8
120 1
83 SFI2
BATH A-2
120 1
83 SFI2
BATH A-3
120 1
83 SFI2
BATH A-4
120 1
82 SFI2
BATH A-5
120 1
82 SFI2
BATH A-6
120 1
82 SFI2
BATH A-7
120 1
S
F I2
B A
T H
B -1
S
F I2
B A
T H
B -2
11 SFS
OX
300 1
77 SF
PUBLIC
TOILET
S
F S
S T
O R
A G
E
84 SFS
EQUIPMENT
300 1
68 SFS
HAC
300 1
221 SFB
CLINICAL
100 3
S
F S
L A
U N
D R
Y
77 SFS
CLEAN LINEN
300 1
S
F S
S O
IL
E
D H
O L D
IN
G
94 SFS
SUPPLIES
300 1
10 SFS
PANTRY
300 1
S
F M
B
IO
M E
D
403 SFM
MECH
300 1
S
F M
O
IT
29 SFS
STORAGE
300 1
S
F S
S T
O R
A G
E
FEC
FEC
96'-4" TRAVEL
107'-10" TRAVEL
SMOKE
COMPARTMENT 1:
6,637SF
SMOKE
COMPARTMENT 2:
4,461SF
WIDTH MAX.
DOOR
UTILIZED
114B
3'-0" 180
WIDTH MAX.
DOOR
UTILIZED
7'-6" 440
WIDTH MAX.
DOOR
UTILIZED
3'-8" 220
WIDTH MAX.
DOOR
UTILIZED
3'-8" 220
WIDTH MAX.
DOOR
UTILIZED
7'-6" 440
PATH OF TRAVEL
8' - 0" CLEAR
WIDTH MAX.
DOOR
UTILIZED
111B
3'-8" 220
FE
APPLICABLE
BUILDING CODES
Department of Veteran Affairs Fire Protection Design Manual - 7th edition
(FPDM)
2015 Life Safety Code, NFPA 101 (LSC)* VA adopts the National Fire Codes published by NFPA, fire protection design must be based upon the latest editions of the NFC at the Date of Award of the contract to the Architectural/Engineering firm.
2015 International Building Code - fire protection features not addressed by the NFC or FPDM must be designed to comply with IBC *Code referenced unless otherwise noted.
ALLOWABLE HEIGHT AND AREA PER BUILDING
OCCUPANCY
CLASSIFICATION
Healthcare, Nursing Home
CONSTRUCTION TYPE Type V(111); combustible, 1-hour rated
SPRINKLER SYSTEM Equipped throughout with an automatic sprinkler system in accordance with 903.3.1.1
LIFE SAFETY / BUILDING CODE SUMMARY
TRAVEL DISTANCE
RESTRICTIONS
(NFPA 101, 2015 ED.)
• Dead-end Corridor Limit: 30ft
• Common Path of Travel: 100ft
• Travel Distance to Exits: 200ft from room door to exit access or exit
• Travel Distance from Room: 50ft
(18.2.6.2.1, 18.2.6.2.3, 18.2.5.3)
1 story; 50 ft Area not regulated by NFPA 101
1 story; 36 ft 11,099 sf
ACTUAL HEIGHT AND
BUILDING AREA
TABULAR VALUES:
MISCELLANEOUS
REQUIREMENTS
• Two accessible exits required (18.2.4.2)
• An exit capacity of 0.2 in/occupant must be provided for horizontal travel such as doors, ramps, etc. in I-2 Occupancies. (18.2.3.2)
BUILDING USE (2) Buildings in Project Scope. These facilities will be used for the long term care and rehabilitation of residents who are otherwise incapable of caring for themselves. 24 Hour Care will be provided.
FIRE RESISTANCE
RATING REQ'TS FOR
BUILDING ELEMENTS
Structural Frame 1 HR
Bearing Walls Exterior 1 HR Interior 1 HR
Non Bearing Walls Exterior 0 HR Interior 0 HR
Floor Construction N/A - Slab on Grade
Roof Construction 1 HR
• Private Parking Garage must be separated from the home by a 1-hour fire barrier with a 45-minute door (406.6.4, Table 508.4, IBC)
• 1-hour smoke barriers are required to divide every story used by inpatients for sleeping or treatment into not less than two smoke compartments. Each smoke compartment must not exceed 22,500
sq. ft. The travel distance from any point to reach a door in the smoke barrier must not exceed 200 feet. (18.3.7.1, 18.3.7.3; 2.10, FPDM)
• Not less than 30 net sq. ft. per bed or litter patient must be provided on each side of the smoke barrier. Not less than 6 sq. ft. per occupant required for smoke compartments on stories not housing bed or litter patients must be provided on each side of the smoke barrier.
(18.3.7.5.1)
• Doors in a smoke barrier must be substantial doors such as 1 3/4 in thick solid-bonded wood core doors or be 20 minute rated assemblies. Doors must be self or automatic closing. (18.3.7.6, 18.3.7.8, 18.3.7.9)
• At least two exits must be accessible from each smoke compartment.
Means of egress may pass through adjacent zones as long as they do not return through the zone of fire origin. (18.2.4.4)
• Fire dampers are required at duct penetrations of fire walls.
• Smoke dampers are not required at duct penetrations of shafts, fire barriers, or fire walls. Smoke dampers are not required in duct penetrations of smoke barriers in fully ducted heating, ventilating, and air conditioning systems. Smoke dampers are not required where duct openings are limited to a single smoke compartment and the ducts are of steel construction. Ceiling radiation dampers required for membrane penetrations of 1-hour rated ceiling assemblies. (8.5.5.3 & 18.3.7.3)
• Corridors in nursing homes are permitted to be a minimum of 6 feet in clear and unobstructed width in smoke compartments not housing more than 30 patients. Corridors in adjunct areas not intended for the housing, treatment, or use of inpatients must not be less than 44 inches in clear and unobstructed width. (18.2.3.4(1)&(7))
• Corridor walls must limit the transfer of smoke. Walls are permitted to terminate at the ceiling where the ceiling is constructed to limit the transfer of smoke. Corridor doors must be provided with positive latching hardware. Doors to toilet rooms, shower rooms, bathrooms, sink closets, and similar auxiliary spaces that do not contain flammable or combustible materials are not required to latch or resist the passage of smoke. (18.3.6.2, 18.3.6.3, 18.3.6.3(3), 18.3.6.3.6)
• Dead end corridors must not exceed 30 feet. (18.2.5.2)
REQ'D SEPARATIONS
CODE LEGEND
EXIT
SEMI RECESSED FIRE EXTINGUISHER CABINET W/ FIRE
EXTINGUISHER. VERIFY LOCATIONS AND QUANTITIES W/
APPLICABLE CODES, OWNER AND FIRE MARSHAL.
FEC
1 HR FIRE RATED INTERIOR WALL (BEARING) (FIRE
RESISTANT AND SMOKE RESISTANT) (RATING APPLIES TO
PROTECTION OF THE STRUCTURE OF THE WALL ONLY, AND
NOT THE WALL ITSELF)
SMOKE COMPARTMENT (SMOKE BARRIER, 1 HR FIRE
RESISTANT)
1 HR FIRE RATED (FIRE BARRIER)
SUITE OF ROOMS ( ≤ 10,000 SF)
EXTERIOR BEARING WALL (1 HR FIRE RATED)
(EXPOSED TO FIRE FROM INTERIOR SIDE ONLY) (RATING
APPLIES TO PROTECTION OF THE STRUCTURE OF THE
WALL ONLY, AND NOT THE WALL ITSELF)
BRACKET MOUNTED PORTABLE FIRE EXTINGUISHER. VERIFY
LOCATIONS AND QUANTITIES W/ APPLICABLE CODES, OWNER
AND FIRE MARSHAL.
FE
NOTES:
WHERE FIRE BARRIERS OR FIRE WALLS EXTEND ABOVE A CEILING, SUCH WALLS
SHALL BE LABELLED PERMANENTLY AND APPROPRIATELY USING SIGNS OR
STENCILS COMPLYING WITH THE BUILDING CODE.
A SINGLE (1) TYPE 'K' FIRE EXTINGUISHER SHALL BE PROVIDED IN A CABINET OF THE
KITCHEN COOKING AREA.
SMOKE PARTITION (SMOKE RESISTANT)
1 HR FIRE RATED INTERIOR WALL (BEARING) (FIRE
RESISTANT AND SMOKE RESISTANT)
EGRESS LEGEND
ROOM
X
# SF
ROOM NAME
ROOM AREA
NUMBER OF
EXITS REQ'D
OCCUPANCY
TYPE
AREA PER
OCCUPANT
PER CODE
ACTUAL NUMBER
OF OCCUPANTS
IN ROOM
XX'-0" TRAVEL
MAX. TRAVEL
DISTANCE TO
EXIT
DOOR
DOOR #
WIDTH MAX
3'-0" 240
UTILIZED 72
DOOR WIDTH
UTILIZED
OCCUPANT LOAD
MAX OCC.
LOAD
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
LEXINGTON VAMC, LEESTOWN DIVISION
2250 LEESTOWN ROAD
LEXINGTON, KY 40511
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
Project Number Scale
15-584
CONSTRUCT CONTINUING
CARE FACILITES - PHASE 1
596-332AS INDICATED
FULLY SPRINKLERED
BID DOCUMENTS
E D
C B
A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
SEPTEMBER 16, 2018
# 202
/1
/2
:3
:3
P
M
GI121
BUILDING 202 - FIRST FLOOR LIFE
SAFETY PLAN
4 5DLW VFS
1/8" = 1'-0"
GI121
1 FIRST FLOOR LIFE SAFETY PLAN
NOTES:
1. EXTERIOR CONTENT IS SHOWN FOR REFERENCE
ONLY. REF. TO EXTERIOR ARCHITECTURE
SHEETS FOR FURTHER INFORMATION.
2. THIS SHEET SHALL ALWAYS BE VIEWED IN
COLOR, NOT BLACK AND WHITE.
2.12.22.4
2.A
2.B
2.C
2.D
2.3
2.E
2.F
1.1 1.2 1.3 1.4
1.A
1.B
1.C
1.D
1.E
1.F
RATED ASSEMBLY LEGEND
1-HR RATED FLOOR (UL #L511, SYSTEM NO. 5)
1-HR RATED ROOF (UL #P522)
1-HR RATED ROOF (UL #P545)
1-HR RATED ROOF (UL #P522) W/
(1) LAYER 1/2" OSB SHEATHING BETWEEN
RESILIENT CHANNELS AND GYPSUM BOARD
1-HR RATED ROOF (GA #RC2601) @ DORMERS
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
LEXINGTON VAMC, LEESTOWN DIVISION
2250 LEESTOWN ROAD
LEXINGTON, KY 40511
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
Project Number Scale
15-584
CONSTRUCT CONTINUING
CARE FACILITES - PHASE 1
596-332AS INDICATED
FULLY SPRINKLERED
BID DOCUMENTS
E D
C B
A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
SEPTEMBER 16, 2018
# 201 & 202
/1
/2
:3
:4
P
M
GI131
RATED ASSEMBLIES PLANS
5 5DLW VFS
1/8" = 1'-0"
GI131
2 FIRST FLOOR RATED ASSEMBLY PLAN - BUILDING 202
1/8" = 1'-0"
GI131
1 FIRST FLOOR RATED ASSEMBLY PLAN - BUILDING 201
NN
NOTES:
1. EXTERIOR CONTENT IS SHOWN FOR
REFERENCE ONLY. REF. TO EXTERIOR
ARCHITECTURE SHEETS FOR FURTHER
INFORMATION.