FIRE ALARM SYMBOL LEGEND
FIRE ALARM PULL STATION
SYMBOL HEIGHT DESCRIPTION
ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.
TOP: HEIGHT TO TOP OF DEVICE
ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.
F
F
S
FIRE ALARM SPEAKER
FIRE ALARM STROBE
FIRE ALARM PULL SPEAKER AND STROBE
FIRE ALARM DOOR OPEN HOLDER
FIRE ALARM SMOKE DETECTOR
FIRE ALARM CEILING MOUNTED SPEAKER
P
FIRE ALARM DUCT SMOKE DETECTOR
FIRE ALARM HEAT DETECTOR
48"
90"
90"
90"
FIRE ALARM PANEL
FIRE ALARM NAC PANEL
FIRE ALARM ANNUNCIATOR PANEL
FLOW SWITCH
FAP
NAC
FAAP
TAMPER SWITCH
POST INDICATOR VALVEPIV
REMOTE LIGHT/TEST SWITCH FOR DUCT DETECTORS
F FIRE ALARM BELL90"
XX - CANDELA
XX - CANDELA
XX - WATTAGE
H
SMOKE DAMPER
FIRE ALARM CONTROL RELAY
SD
R
F S
F S
NOTES:
1. FIRE ALARM SYSTEM SHALL BE INTERCONNECTED WITH
ACCESS CONTROL SYSTEM TO ALLOW EGRESS
DURINGALARM CONDITIONS. COORDINATE BETWEEN
ACCESS CONTROL SYSTEM AND FIRE ALARM SYSTEM
MANUFACTURERS.
2. ALL FIRE ALARM WIRING SHALL BE IN FACTORY PAINTED
"RED" EMT CONDUIT.
3. ALL WIRING SHALL BE AS RECOMMENDED BY
MANUFACTURER.
4. PROVIDE SEPERATE OUTPUT SIGNALS TO AIR HANDLER
UNIT VFD FOR INDIVIDUAL UNIT SHUT-DOWN. KEEP
EXHAUST FAN ON.
5. PROVIDE ZONE ADAPTER MODULES TO CONNECT NON
ADDRESSABLE DEVICES SUCH AS FLOW AND TAMPER
SWITCHES, DOOR HOLD-OPEN DEVICES, AND CONTROL
SIGNALS.
6. PROVIDE POWER SUPPLY AND/OR NAC (NOTIFICATION
APPLIANCE CIRCUIT) PANEL AS REQUIRED FOR
ADDITIONAL DEVICES.
7. PROVIDE POWER AMPLIFIERS FOR ALL SPEAKERS.
8. THE NEW FIRE ALARM SYSTEM SHALL MATCH THE
EXISTING NOTIFIER FIRE ALARM SYSTEM
FS TS
TO ADDITIONAL
INDICATING
APPLIANCES
TO ADDITIONAL FLOW
AND TAMPER SWITCHES
TO
ADDITIONAL
INITIATING
DEVICES
TO SMOKE DAMPERS
NEW FIRE
ALARM PANEL
(FAP)
SPRINKLER SYSTEM DEVICES
S S S TO ADDITIONAL FIRE
ALARM SPEAKERS
R R
CONTROL RELAY
FOR AUTO DOORS
(TYPICAL)
F
F P
RFOR PACS
FIRE ALARM
SYSTEM REMOTE
ANNUNCIATOR
(FAAP)
EXISTING FIRE
ALARM PANEL IN
BUILDING 17, SEE
TS101 AND TS102
FOR MORE
INFORMATION
NAC
PANEL
TO ADDITIONAL
FIRE ALARM
DEVICES
F S
F S
FIBER SEE SITE PLAN
R
R
COOKING POWER
SUPPLY SHUT OFF
KITCHEN HOOD
SUPPRESTION SYSTEM
120V
TO CLC
DUCT SMOKE DETECTOR *
AREA SMOKE DETECTOR *
DOOR RELEASE SMOKE DETECTOR *
ELEVATOR SMOKE DETECTOR *
MANUAL PULL STATION
ELEVATOR MACHINE ROOM HEAT DETECTOR
GENERATOR ROOM HEAT DETECTOR
SPRINKLER WATERFLOW/PRESSURE SWITCH
WATER CONTROL VALVE TAMPER
FIRE PUMP (ANY ALARM CONDITION REQUIRED BY
(NFPA 20)
HIGH/LOW PRESSURE DRY-PIPE SPRINKLER
SYSTEM
KITCHEN HOOD SUPPRESSION SYSTEM
GAS EXTINGUISHING SYSTEMS
DRY-PIPE VALVE ROOM TEMPERATURE ALARM
DEDICATED FIRE WATER STORAGE TANK LOW LEVEL
DEDICATED FIRE WATER STORAGE TANK LOW
TEMPERATURE
* WHILE NFPA 101 DOES NOT REQUIRE SOME DETECTORS TO NOTIFY BUILDING OCCUPANTS, VA REQUIRES ALL SMOKE DETECTORS, OTHER THAN DUCT SMOKE DETECTORS, TO NOTIFY BUILDING OCCUPANTS AS REQUIRED BY THE LIFE SAFETY CODE OR ITS REFERENCES.
** THOSE DOORS THAT ARE REQUIRED TO BE TIED TO THE FIRE ALARM SYSTEM SUCH AS DELAYED EGRESS AND ACCESS CONTROLLED DOORS.
a - DO NOT PROVIDE DUCT DETECTORS IN DEDICATED (100%) EXHAUST FANS, THEY SHOULD CONTINUE TO RUN.
FIRE ALARM SYSTEM INPUT/OUTPUT MATRIX
OUTPUT
INPUT DEVICE 1.
S
O U
N D
G
EN
ER
AL
BU
IL
D
IN
G A
LA
R
M F
O R
O
TH
ER
H
IG
H
R
IS
E (N
O N
H
EA
LT
H C
AR
E)
. S
EE
SE
C
TI
O
N
.2 .1
2.
N
O
TI
FY
N
EC
ES
SA
R
Y
ST
AF
F
FO
R
R
ES
PO
N
SE
FO
R H
EA
LT
H C
AR
E
AN
D
H
IG
H R
IS
E
BU
IL
D
IN
G S
O N
LY
(A
LA
R
M S
IG
N
AL
M
AY
BE
D
IF
FE
R
EN
T
O N
D
IF
FE
R
EN
T
FL
O
O R
S)
3.
N
O
TI
FY
F
IR
E
D
EP
AR
TM
EN
T
4.
IN
IT
IA
TE
S
U
PE
R
VI
SO
R
Y
SI
G N
AL
T
O A
4-
H O
U R
M
AN
N
ED
P O
IN
T
FO
R
IM
M
ED
IA
TE
R
ES
PO
N
SE
5.
C
LO
SE
A
SS
O C
IA
TE
SM
O
KE
B
AR
R
IE
R
D O
O R
S O
N T
H E
FL
O
O R
6.
C
LO
SE
D
AM
PE
R
S O
N
FA
N P
R O
XI
M
AT
E
TO
D
ET
EC
TO
R
7.
S
H U
T D
O W
N A
IR
H
AN
D
LE
R
S
ER
VE
D
B Y
TH
E
D
ET
EC
TO
R
8.
R
EC
AL
L
EL
EV
AT
O R
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
XX X
ALTERNATE NOTES
ALTERNATE DEDUCT #1:
OMIT CONNECTING CANOPY STRUCTURE BETWEEN BUILDINGS AND CANOPY
EXTENSION TO PARKING AREA. OMIT ALL STEEL STRUCTURE, CLADDING,
FOUNDATION AND ELECTRICAL LIGHTING CONNECTED TO CANOPY. SIDEWALK TO
REMAIN. IN LIEU OF THE INTEGRATED PATIENT HEALTHCARE CASEWORK, PROVIDE
SUSPENDED MANUFACTURED PLASTIC CASEWORK WITH SOLID SURFACE
COUNTERTOP AND BACKSPLASH. ALL OTHER DESIGN ELEMENTS ARE TO REMAIN THE
SAME. OMIT PAVING AND BASE AT THE PARKING SPACES REMOTE FROM THE
SIDEWALKS ACCESSING THE BUILDINGS. PROVIDED SEEDED AREA IN PLACE OF THE
PAVING, MATCHING THE ADJACENT SEEDED AREAS TO INCLUDE TOPSOIL AS
REQUIRED.
THE PERIOD OF PERFORMANCE FOR THE WORK IN ALTERNATE DEDUCT #1 IS 460
CALENDAR DAYS FROM RECEIPT OF NOTICE TO PROCEED.
ALTERNATE DEDUCT #2:
UTILIZE STANDARD 3-TAB SHINGLES AS SPECIFIED IN LIEU OF DIMENSIONAL
SHINGLES.
THE PERIOD OF PERFORMANCE FOR THE WORK IN ALTERNATE DEDUCT #2 IS 460
CALENDAR DAYS FROM RECEIPT OF NOTICE TO PROCEED.
ALTERNATE DEDUCT #3:
SUBSTITUTE HEAVY DUTY ASPHALT FOR HEAVY DUTY CONCRETE WHERE INDICATED
ON THE SITE PLAN EXCEPT AT THE PAD ADJACENT TO THE OXYGEN TANK INDICATED
ON CS101.
THE PERIOD OF PERFORMANCE FOR THE WORK IN ALTERNATE DEDUCT #3 IS 460
CALENDAR DAYS FROM RECEIPT OF NOTICE TO PROCEED.
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot th re e ei gh th s in ch o ne fo ot on e ha lf in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot 6" on e in ch o ne fo ot 6" on e an d on e ha lf in ch es o ne fo ot 6" th re e in ch es o ne fo ot
6"
LEXINGTON VAMC, LEESTOWN DIVISION
2250 LEESTOWN ROAD
LEXINGTON, KY 40511
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER: Project Number Scale 15-584
A/E CONSTRUCT CONTINUING
CARE FACILITES, PHASE 1
596-332AS INDICATED
FULLY SPRINKLERED
BID DOCUMENTS
E D
C B
A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
# 201 & 202
10/22/18
3/ 6/
:1
6:
P M
FA001
FIRE ALARM NOTES, LEGEND, AND
ABBREVIATIONS
1 5JKM JWB
FIRE ALARM GENERAL NOTES
1. FIRE ALARM SYSTEM AND COMPONENTS SHALL MEET THE FOLLOWING CODES:
a. NFPA 13- STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEM.
b. NFPA 14- STANDARD FOR THE INSTALLATION OF STANDPIPE SYSTEM.
c. NFPA 20- STANDARD FOR THE INSTALLATION OF FIRE PUMP.
d. NFPA 70 NATIONAL ELECTRIC CODES.
e. NFPA 72 NATIONAL FIRE ALARM CODE.
f. NFPA 90A STANDARD FOR THE INSTALLATION OF AIR CONDITIONING.
g. NFPA 101 LIFE SAFETY CODE.
h. VA STANDARDS.
i. ANSI S3.41 AUDIBLE EMERGENCY EVACUATION
j. NFPA 88A STANDARD FOR PARKING STRUCTURE
2. FIRE ALARM SYSTEM SHALL COMPLY WITH FACTORY MUTUAL RESEARCH
CORPORATION (FM).
3. ALL FIRE ALARM CABLING SHALL BE IN CONDUIT. CONDUIT SHALL BE FACTORY
PAINTED RED.
4. THE NOTIFIER SYSTEM VENDOR/CONTRACTOR SHALL TERMINATE, TEST AND
PROGRAM ALL NEW FIRE ALARM DEVICES. COORDINATE WITH COR.
5. CONNECT ALL SPRINKLER DEVICES TO THE FIRE ALARM SYSTEM. COORDINATE
LOCATION WITH THE SPRINKLER CONTRACTOR.
6. CONNECT ALL ELECTROMAGNETIC DOOR HOLD OPEN DEVICES TO THE FIRE
ALARM SYSTEM. COORDINATE WITH THE DOOR HARDWARE CONTRACTOR.
7. PROVIDE RELAY FOR COOKING EQUIPMENT.
8. PROVIDE RELAY FOR COOKING SUPRESSION SYSTEM.
9. PROVIDE SMOKE DETECTORS AND ALL REQUIRED RELAYS TO CONTROL THE
SMOKE DAMPERS.
N.T.S.FA001
1 FIRE ALARM RISER TYPICAL
ADDENDUM 4 03/06/19