This is a Single Source Justification form for a Simplified Acquisition Procedure (SAP) under the Simplified Acquisition Threshold (SAT) of $250,000.
The Department of Veterans Affairs, VISN 07, Ralph H. Johnson VA Medical Center requires fire protection and fire alarm system equipment for a facility upgrade. The acquisition includes Ruskin Fire-Smoke Dampers and actuators, along with fire sprinkler assemblies in two types: Type D upright sprinkler heads (Tyco TY3151, Reliable Model G, Viking QR VK300/VK350 Brass Upright, or Victaulic Model V27 Upright) and Type A semi-recessed ordinary coverage sprinkler heads (Tyco TY3251, Reliable Model FI Head & Model G-FI Escutcheon, Viking QR VK302/VK352 Pendent, or Victaulic Model 34). The estimated total cost is not disclosed in the available document. The justification cites FAR 6.302-1, asserting that only one responsible source exists because the specified equipment is necessary to ensure compatibility with the existing Gamewell FCI fire alarm control panel system and to maintain Factory Mutual and Underwriter's Laboratory certifications. The systems must function as a unified, cohesive assembly tested and certified together to comply with NFPA standards and the VA Fire Protection Design Manual. No market research was conducted due to these compatibility requirements. The Contracting Officer, Kenyon Dulaney, certified the justification on May 20, 2026, and must document price reasonableness using the S19 Open Market Award Documentation Form.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHAPG Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT
Revision: 01 Effective Date: 11/15/2024 Page 1 of 2 Acquisition ID#:
DEPARTMENT OF VETERANS AFFAIRS
Justification for Single Source Awards IAW FAR 13.106-1 For
Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K)
Acquisition Plan Action ID:
1. Contracting Activity: Department of Veterans Affairs, VISN 07, Ralph H. Johnson VA Medical Center
2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:
The Ralph. H Johnson VAMC has a requirement to utilize specific products for basis of design. The requested brands for fire sprinklers and dampers are necessary to meet requirements and interface with existing hospital equipment. This equipment must be installed to maintain Factory Mutual/Underwriter’s Laboratory requirements for a unified system built and tested together. The fire dampers must integrate with the Gamewell FCI fire alarm control panel system to function properly and continue manufacturer certification that the fire alarm system will work as intended and per NFPA and VA Fire Protection Design Manual requirements.
Basis of design to be Ruskin Fire-Smoke Dampers and actuators and fire sprinkler assemblies as follows:
Type D upright sprinkler heads where Type D, defined as one of the following:
1. Tyco TY3151
2. Reliable Model G
3. Viking QR VK300 / VK350 Brass Upright
4. Victaulic Model V27 Upright
Type A semi-recessed ordinary coverage sprinkler heads where Type A, defined as one of the following:
1. Tyco TY3251
2. Reliable Model FI Head & Model G-FI Escutcheon
3. Viking QR VK302 / VK352 Pendent
4. Victaulic Model 34
The total cost for the above items is estimated to be approximately $
3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:
Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements per FAR 6.302-1. The listed supplies described are the only materials that can ensure compatibility with the existing fire protection and fire alarm systems that are in place. These systems must be uniform as that is how they are tested by the manufacturer and certified by national testing bodies
36C247-26-AP-2508
VHAPG Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT
Revision: 01 Effective Date: 11/15/2024 Page 2 of 2 Acquisition ID#:
(Factory Mutual and Underwriter Laboratories). In order to maintain certifications that these systems meet code and VA design manual requirements, particular equipment must be installed to maintain certifications that the system will function properly and save life and property when activated.
4. Description of market research conducted and results or statement why it was not conducted:
Market research was not conducted because the supplies listed are necessary to form a unified, cohesive, and compliant fire protection and fire alarm system.
5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106-1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.
Note: COs are required to make a determination of price reasonableness IAW FAR 13.106-3. See the