This specification section outlines wall and door protection products required for the Build out Community Living Center Building 72 project. Resilient materials must meet fire resistance, impact resistance, and self-extinguishing standards. Corner guards, handrails, and wall guards are to be surface mounted or flush mounted as needed. Products include resilient or aluminum wall guards and handrails, as well as prefabricated accessories. Finishes for aluminum are specified as chemically etched and anodized. Installation requirements define securing resilient products with brackets and fasteners according to manufacturer instructions. The related federal contract opportunity is for solicitation 36C24623B0045 to provide products and services for the Z2DZ--Build out Community Living Center Building 72 Project No: 565-21-103, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6.
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS 11-15-23
10 26 00 - 1
SECTION 10 26 00
WALL AND DOOR PROTECTION
PART 1 - GENERAL
1.1 DESCRIPTION
A. This section specifies wall guards, handrail,and corner guards .
1.2 RELATED WORK
A. Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS: Sustainable
Design Requirements.
B. Section 05 50 00, METAL FABRICATIONS: Structural Steel Corner Guards.
C. Section 08 71 00, DOOR HARDWARE: Armor plates and kick plates not specified in this section.
D. Section 09 06 00, SCHEDULE FOR FINISHES: Color and texture of aluminum and resilient material.
1.3 QUALITY ASSURANCE
A. Manufacturer’s Qualifications: Manufacturer with a minimum of three (3) years’ experience in providing items of type specified.
1. Obtain wall and door protection from single manufacturer.
B. Installer’s Qualifications: Installers are to have a minimum of three
(3) years’ experience in the installation of units required for this project.
1.4 SUBMITTALS
A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT
DATA, AND SAMPLES.
B. Sustainable Design Submittals, as described below:
1. Volatile organic compounds per volume as specified in PART 2 -
PRODUCTS.
C. Shop Drawings: show design and installation details.
D. Manufacturer's Literature and Data:
1. Handrail
2. Corner Guards.
E. Test Report: Showing that resilient material complies with specified fire and safety code requirements.
F. Manufacturer’s qualifications.
G. Installer’s qualifications.
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
ISSUED FOR CONSTRUCTION
95% CONSTRUCTION DOCUMENTS 11-15-23
10 26 00 - 2
H. Manufacturer’s warranty.
1.5 DELIVERY AND STORAGE
A. Deliver materials to the site in original sealed packages or containers marked with the name and brand, or trademark of the manufacturer.
B. Protect from damage from handling and construction operations before, during and after installation.
C. Store in a dry environment of approximately 21 degrees C (70 degrees F) for at least 48 hours prior to installation.
1.6 WARRANTY
A. Construction Warranty: Comply with FAR clause 52.246-21 “Warranty of
Construction”.
B. Manufacturer Warranty: Manufacturer shall warranty their wall and door protection for a minimum of five (5) years from date of installation and final acceptance by the Government. Submit manufacturer warranty.
1.7 APPLICABLE PUBLICATIONS
A. publications listed below form a part of this specification to extent referenced. publications are referenced in text by basic designation only.
B. ASTM International (ASTM):
A240/A240M-20...........Chromium and Chromium-Nickel Stainless Steel
Plate, Sheet, and Strip for Pressure Vessels and For General Applications
B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)
D256-10(2018)...........Determining the Izod Pendulum Impact Resistance of Plastics
D635-18.................Rate of Burning and/or Extent and Time of
Burning of Plastics in a Horizontal Position
E84-20..................Surface Burning Characteristics of Building
Materials
C. Aluminum Association (AA):
DAF 45-09...............Designation System for Aluminum Finishes
D. American Architectural Manufacturers Association (AAMA):
611-14..................Voluntary Specification for Anodized
Architectural Aluminum
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
95% CONSTRUCTION DOCUMENTS 11-15-23
10 26 00 - 3
E. Code of Federal Regulation (CFR):
40 CFR 59(2020) Subpart D National Volatile Organic Compound
Emission Standards for Architectural Coatings
F. The National Association of Architectural Metal Manufacturers (NAAMM):
AMP 500-06..............Metal Finishes Manual
G. National Fire Protection Association (NFPA):
80-2019.................Standard for Fire Doors and Other Opening
Protectives
H. SAE International (SAE):
J 1545-2014-10..........Instrumental Color Difference Measurement for
Exterior Finishes, Textiles and Colored Trim.
I. Underwriters Laboratories Inc. (UL):
Annual Issue............Building Materials Directory
PART 2 - PRODUCTS
2.1 MATERIALS
A. Resilient Material:
1. Provide resilient material consisting of high impact resistant extruded acrylic vinyl, polyvinyl chloride, or injection molded thermal plastic conforming to the following:
a. Minimum impact resistance of 960.8 N-m/m (18 feet-pounds/square inch) when tested in accordance with ASTM D256 (Izod impact, feet-pounds per inch notched).
b. Class 1 fire rating when tested in accordance with ASTM E84, having a maximum flame spread of 25 and a smoke developed rating of 450 or less.
c. Rated self-extinguishing when tested in accordance with
ASTM D635.
d. Provide material labeled and tested by Underwriters Laboratories or other approved independent testing laboratory.
e. Provide resilient material for protection on fire rated doors and frames assemblies that is listed by the testing laboratory performing the tests.
f. Provide resilient material installed on fire rated wood/steel door and frame assemblies that have been tested on similar type assemblies. Test results of material tested on any other combination of door and frame assembly are not acceptable.
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
95% CONSTRUCTION DOCUMENTS 11-15-23
10 26 00 - 4
g. Provide integral color with colored components matched in accordance with SAE J 1545 to within plus or minus 1.0 on the
CIE-LCH scales.
2.2 CORNER GUARDS
A. Resilient, Shock-Absorbing Corner Guards: Surface mounted type.
1. snap-on corner guard formed from resilient material, minimum 1.98 mm
(0.078-inch) thick, free floating on a continuous 1.52 mm
(0.060-inch) thick extruded aluminum retainer.
2. Profile: Minimum 50 mm (2 inch) long leg and 6 mm (1/4 inch) corner radius
3. Height: 1.22 m (4 feet).
4. Retainer Clips: Provide manufacturer’s standard impact-absorbing clips.
5. Provide factory fabricated end closure caps at top and bottom of surface mounted corner guards.
6. Flush mounted corner guards installed on any fire rated wall to be installed in a manner that maintains the fire rating of the wall.
Provide fire test of proposed corner guard system to verify compliance.
a. Where insulating materials are an integral part of the corner guard system, provide insulating materials furnished by the manufacturer of the corner guard system.
2.3 WALL GUARDS AND HANDRAILS
A. Resilient Wall Guards and Handrails:
1. Handrail/Wall Guard Combination:
a. Snap-on covers of resilient material, minimum 2 mm (0.078-inch) thick.
b. Free-floating on a continuous, extruded aluminum retainer, minimum 1.82 mm (0.072-inch) thick.
c. Anchor to wall at maximum 762 mm (30 inches) on center.
2. Wall Guards:
a. Snap-on covers of resilient material, minimum 2.54 mm (0.100-inch) thick. Free-floating over 51 mm (2 inch) wide aluminum retainer clips, minimum 2.28 mm (0.090-inch) thick, anchored to wall at maximum 610 mm (24 inches) on center, supporting a
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
95% CONSTRUCTION DOCUMENTS 11-15-23
10 26 00 - 5 continuous aluminum retainer, minimum 1.57 mm (0.062-inch) thick .
3. Provide handrails and wall guards with prefabricated end closure caps, inside and outside corners, concealed splices, cushions, mounting hardware and other accessories as required. End caps and corners to be field adjustable to assure close alignment with handrails and wall guards. Screw or bolt closure caps to aluminum retainer in a concealed manner.
B. Aluminum Wall Guards: Extruded aluminum, closed tubular bumper assembly mounted on wall brackets.
1. Provide wall bumper with factory fabricated end closure caps, and inside and outside corner assemblies, concealed splice plates, and other accessories standard with the manufacturer.
2. Fabricate tubular wall guards from material with a nominal wall thickness of 6.35 mm (0.250-inch), form grooves for and provide two (2) strips of continuous polyvinyl chloride cushion bumper inserts.
3. Fabricate adjustable wall brackets from aluminum having a nominal wall thickness of 5.08 mm (0.20-inch). Fasten bumper to brackets with 6.35 mm (1/4-inch) diameter aluminum or stainless steel bolts with locknuts.
C. Stainless Steel Wall Guards: Construct wall guard, including brackets, of minimum 4.76 mm (0.1875-inch) thick stainless steel.
2.4 DOOR AND DOOR FRAME PROTECTION
A. Not Used.
2.5 HIGH IMPACT WALL COVERING
A. Not Used.
2.6 FASTENERS AND ANCHORS
A. Provide fasteners and anchors as required for each specific type of installation.
B. Where type, size, spacing or method of fastening is not shown or specified in construction documents, submit shop drawings showing proposed installation details.
2.7 FINISH
A. Aluminum: In accordance with AA DAF-45.
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
95% CONSTRUCTION DOCUMENTS 11-15-23
10 26 00 - 6
1. Exposed aluminum: AAMA 611 AA-M12C22A31 chemically etched medium matte, with clear anodic coating, Class II Architectural, .01 mm
(0.4 mil) thick.
2. Concealed aluminum: Mill finish as fabricated, uniform in color and free from surface blemishes.
B. Stainless Steel: In accordance with NAAMM AMP 500 finish Number 4.
C. Resilient Material: Embossed textures and color in accordance with
SAE J1545.
PART 3 - INSTALLATION
3.1 RESILIENT CORNER GUARDS
A. Install corner guards on walls in accordance with manufacturer's instructions.
3.2 STAINLESS STEEL CORNER GUARDS
A. Not Used.
B. Where corner guards are installed on gypsum board, clean surface and anchor guards with a neoprene solvent-type contact adhesive specifically manufactured for use on gypsum board construction. Remove excess adhesive from around edge of guard and allow curing undisturbed for 24 hours.
3.3 RESILIENT HANDRAILS
A. Secure guards to walls with bracketsand fasteners in accordance with manufacturer's details and instructions.
3.4 ALUMINUM WALL GUARDS
A. Not Used.
3.5 STAINLESS STEEL WALL GUARDS
A. Not Used.
3.6 DOOR, DOOR FRAME PROTECTION AND HIGH IMPACT WALL COVERING
A. Not Used.