This specification section outlines requirements for directories to be installed at a Department of Veterans Affairs Community Living Center project. Non-illuminated message strip directories are specified, with profiled acrylic frames and message strips to indicate locations. Materials include aluminum, stainless steel, clear float glass, clear tempered glass and clear acrylic sheet. Fabrication must meet dimensional and finish requirements. Directories will be surface mounted at locations indicated on construction documents and shop drawings. Adjustment, cleaning and extra materials are addressed. The related federal contract opportunity is a solicitation from the VA Veterans Health Administration VISN 6 to build out Community Living Center Building 72 located at the specified VA medical center project.
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS 11-15-23
10 13 00 - 1
SECTION 10 13 00
DIRECTORIES
PART 1 - GENERAL
1.1 DESCRIPTION
A. This section specifies interior and exterior directories.
1.2 RELATED WORK
A. Section 09 06 00, SCHEDULE FOR FINISHES: Manufacturer, Color and Style.
B. Section 10 14 00, SIGNAGE.
C. Division 26, ELECTRICAL: Electrical Work.
1.3 QUALITY ASSURANCE
A. Manufacturer’s Qualifications: Provide directories that are the product of a single manufacturer that has provided units as specified for a minimum of three (3) years.
1.4 SUBMITTALS
A. Submit in accordance with Section 01 33 00, SHOP DRAWINGS, PRODUCT DATA
AND SAMPLES.
B. Samples: Directory panels and frames, with letters and symbols, each type.
Color samples of each color, 152 mm x 152 mm (6 inches x 6 inches).
Show anticipated range of color and texture.
Sample of typeface (size, font), arrow and symbols in a typical full size layout.
Sample for exposed product trim, 150 mm (6 inches) long for profile and color of factor finish.
Message Strip: Length as indicated for finished product for profile and mounting configuration.
Sample for initial section.
C. Manufacturer's Literature:
Manufacturer’s printed specifications, anchorage details, installation and maintenance instructions.
Manufacturer’s qualifications.
D. Directory location plan showing location and type of each directory.
1.5 DELIVERY AND STORAGE
A. Deliver materials to job in manufacturer's original sealed containers with brand name markings. Protect materials from damage.
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
ISSUED FOR CONSTRUCTION
10 13 00 - 2
B. Package to prevent damage or deterioration during shipment, handling, storage and installation. Maintain protective covering in place and in good repair until removal is necessary.
C. Deliver directories only when the site and mounting services are ready for installation work to proceed.
D. Store products in dry condition inside enclosed facilities.
1.6 APPLICABLE PUBLICATIONS
A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only.
B. ASTM International (ASTM):
A666-15.................Annealed or Cold-Worked Austenitic Stainless
Steel Sheet, Strip, Plate, and Flat Bar
B209-14.................Aluminum and Aluminum-Alloy Sheet and Plate
B209M-14................Aluminum and Aluminum-Alloy Sheet and Plate
(Metric)
B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes
B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes (Metric)
C1036-16................Flat Glass
C1048-18................Heat-Strengthened and Fully Tempered Flat Glass
D1003-13................Haze and Luminous Transmittance of Transparent
Plastics
D4802-16................Poly(Methyl Methacrylate) Acrylic Plastic Sheet
C. American Architectural Manufacturers Association (AAMA):
611-14..................Anodized Architectural Aluminum
2603-13.................Voluntary Specification, Performance
Requirements and Test Procedures for Pigmented
Organic Coatings on Aluminum Extrusions and
Panels
D. National Association of Architectural Metal Manufacturers (NAAMM):
AMP 500 Series..........Metal Finishes Manual
E. Federal Specifications (Fed Spec):
MIL-PRF-8184F...........Plastic Sheet, Acrylic, Modified.
MIL-P-46144C............Plastic Sheet, Polycarbonate
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
10 13 00 - 3
F. National Fire Protection Association (NFPA):
70-14...................National Electric Code
PART 2 - PRODUCTS
2.1 DIRECTORY TYPE
A.Non-Illuminated Message Strip Directories:
Profiled Frame: Molded-opaque-acrylic
Frame:
a. Top and Bottom Profile: Radius.
Mounting: Surface.
Header: Copy applied to top section of profiled frame.
Divider Color: Same as selected message strips.
2.2 MATERIALS
A. Aluminum:
Sheet and Plate: ASTM B209M (B209).
Extrusions and Tubing: ASTM B221M (B221) Alloy 6063.
B. Stainless Steel Sheet: ASTM A666, Type 304.
C. Clear Float Glass: ASTM C1036, Type I, Class 1, Quality q3.
D. Clear Tempered Glass: ASTM C1048, Kind FT, Condition A, Type I, Class 1
(clear) Quality q3 with exposed edges seamed before tempering.
E. Clear Acrylic Sheet: ASTM D4802, Category A-1 (cell cast sheet) with
Finish 1 (smooth or polished) colorless sheet with visible light transmittance of 92 percent measured according to ASTM D1003.
F. Fasteners: Provide screws, bolts, and other fastening devices made from same material as items being fastened except provide hot dipped galvanized, stainless steel, or aluminum fasteners for exterior applications.
G. Electrical Components: Listed and labeled as defined in NFPA 70, by a qualified testing agency.
2.3 FABRICATION
A. Fabricate directories to requirements indicated for dimensions, design, and thickness and finish of materials. Provide metals and shapes of thickness and reinforcement to produce flat surfaces, free of oil canning.
B. Fabricate directory cabinets and door frames with reinforced corners, mitered and welded to a hairline fit, with no exposed fasteners.
Provide structural reinforcement to prevent racking and misalignment.
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
10 13 00 - 4
C. Message-Strip Directories: Provide message strips with wording and other designations for the locations where wording is indicated.
Include blank message strips as needed to fill out remainder of directory.
D. Provide hold-open arms for doors of top-hinged directories.
2.4 GENERAL FINISH REQUIREMENTS
A. Comply with NAAMM AMP 500 for recommendations for applying and designating finishes.
B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.
C. Appearance of Finished Work: Noticeable variations in same piece are unacceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved samples and are assembled or installed to minimize contrast.
2.5 ALUMINUM FINISHES
A. Not Used.
PART 3 - EXECUTION
3.1 INSTALLATION
A. General: Install directories in locations and at mounting heights indicated on construction documents and approved shop drawings. Keep perimeter lines straight, level, and plumb. Comply with accessibility standards.
B. Recessed Directories: Attach directories to wall framing with fasteners at not more than 406 mm (16 inches) centers. Attach aluminum trim over edges of recessed directories, and conceal grounds and clips.
C. Surface-Mounted Directories: Attach directories to wall surfaces with concealed clips, hangers, or grounds fastened at not more than 406 mm
(16 inches) o.c. Secure both top and bottom of directories to walls.
3.2 ADJUSTING AND CLEANING
A. Adjust directory doors to operate smoothly without warp or bind and so that contact points meet accurately. Lubricate operating hardware as recommended by manufacturer.
B. Touch up factory-applied finishes to restore damaged or soiled areas.
3.3 MAINTENANCE MATERIALS
A. Furnish extra materials that match products installed and that are packaged with protective covering for storage with labels describing contents.
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
B72 COMMUNITY LIVING CENTER
95% CONSTRUCTION DOCUMENTS
565-21-103
10 13 00 - 5
Message Strips: Not used.
Paper Message-Strip Stock: Not used.
- - - END - - -