FitForServiceForm_AST_9_signed.pdf

PDF 126 KB Posted

Attached to
Z2NA--AMENDMENT 0003 POST RFI ANSWERS AND DOCUMENTS REQUESTED MARTINSBURG VAMC 36C24526Q0341
Solicitation number
36C24526Q0341
Issued by

About this file

This is an Annual Inspection Certification form for an Aboveground Storage Tank (AST) in West Virginia. The form certifies that AST No. 9 at Martinsburg VA Medical Center, located at 510 Butler Avenue in Martinsburg, WV 25405, is fit for service as of September 30, 2021. Christopher Rua, a qualified individual holding AST-1726 certification (expiring July 6, 2026), performed the evaluation and certified that the tank system meets applicable standards established by WV CSR 47-63. Tank owner Kenneth Allensworth can be reached at 304-263-0811 x 4000 or Kenneth.Allensworth@va.gov. The DEP-issued tank label number is 002-00000338, and the facility has designated this as a Level 1 tank. Rua documented all deficiencies and changes found during the inspection in writing and provided recommendations with a proposed abatement schedule. The certification confirms that Rua personally examined the AST system, including its associated equipment, leak detection system, and secondary containment structure, and based on direct knowledge certifies the tank as fit for service.

View the file

Other files

File Type Posted
Annual Inspection Certification AST 3.pdf PDF
504-BT specs.pdf PDF
36C24526Q0341 0003_1.docx DOCX document
RFI answers.pdf PDF
Annual Inspection Certification AST 1.pdf PDF
20074.AST1.IS.STI.12.20.pdf PDF
20074.AST5.IS.STI.12.20.pdf PDF
20074.AST2.IS.STI.12.20.pdf PDF
20074.AST3.IS.STI.12.20.pdf PDF
Convault_Inspection_3-3-14.pdf PDF
36C24526Q0341 0003.pdf PDF
ERPT_VAMED_Tank1_Final_7-28-06.pdf PDF
FitForServiceForm_AST_10_signed.pdf PDF
Fuel Oil Storage Tanks Plans Sections Existing Boiler House Bldg 320.pdf PDF
ConVault Specification 3-2010.pdf PDF
20074.AST8.IS.STI.12.20.pdf PDF
1 February 2022 - Boiler Tank Lead Inspection - Final Technical Report.pdf PDF
Annual Inspection Certification AST 5.pdf PDF
FitForServiceForm_AST_504-BT_signed.pdf PDF
ERPT_Martinsburg_Tank2_Final_11-02-06.pdf PDF
Annual Inspection Certification AST 8.pdf PDF
Annual Inspection Certification AST 2.pdf PDF
ConVault Maintenance Checklist.pdf PDF
36C24526Q0341 0002_1.docx DOCX document
36C24526Q0341 0002.pdf PDF
36C24526Q0341 0001_1.docx DOCX document
36C24526Q0341 0001.pdf PDF
36C24526Q0341_.pdf PDF
SAM-Service Contract Act Wage Determination 2015-4297.pdf PDF
Martinsburg VA Map 09-06-2022_0.pdf PDF
36C24526Q0341_1.docx DOCX document
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ANNUAL INSPECTION CERTIFICATION

Aboveground Storage Tank

Is Fit for Service

V.7.22.2016

☐ I am a qualified individual as described in WV CSR 47‐63‐5.2 and I have performed a tank evaluation on the above AST system. I certify the tank system meets applicable standards established by WV CSR 47‐63.

☐ I am the tank owner, operator, or qualified representative of the tank owner or operator, and have performed a tank evaluation on the above AST system. I certify there is no obvious change to the tank system that would cause this tank to become not‐fit for service since it was certified by a PE, API or STI inspector on

_______________________ (date). This certification meets the requirements set in WV CSR 47‐63‐5.2.b.3 to certify annual inspections in intervening years between the evaluations required by a PE, API or STI inspector.

In accordance with the WV CSR 47‐63‐5.2, I have documented all deficiencies and/or changes in the tank system found during the inspection, in writing, and provided my recommendations, including a proposed schedule, for abating the deficiencies and submitted them with this form.

I certify that I have personally examined and/or am familiar with the inspection performed on the AST system listed above, including its associated equipment, leak detection system and secondary containment structure, and that based on my direct knowledge that the AST listed above is Fit for Service.

Signature of Certifying Individual Date Signed

P.E. Registration #, STI Certification # or Registration/Certification Expiration Date API

Certification # (if applicable) (if applicable)

AST Facility Name

Address

City, State, Zip

Tank Owner Name

Telephone Number

Email Address

Certifying Individual

Address

City, State, Zip

Telephone Number

Email Address

Facility’s/Owner’s Tank ID

DEP Issued Tank Label

DEP Determined Tank Level Level 1 tank ☐ Level 2 tank ☐

AST Facility Name: Martinsburg VA Medical Center
Address: 510 Butler Avenue
City State Zip: Martinsburg, WV 25405
Tank Owner Name: Kenneth Allensworth
Telephone Number: 304-263-0811 x 4000
Email Address: Kenneth.Allensworth@va.gov
Certifying Individual: Christopher Rua
Address_2: 77 Upper Rock Circle, Suite 302
City State Zip_2: Rockville, MD 20850
Telephone Number_2: 732-278-4279
Email Address_2: chrisr@phe.com
FacilitysOwners Tank ID: AST No. 9
DEP Issued Tank Label: 002-00000338
certify annual inspections in intervening years between the evaluations required by a PE API or STI inspector:
2021-10-04T18:39:33-0400
Christopher Rua
Date Signed: September 30, 2021
PE Registration STI Certification or: AST-1726
RegistrationCertification Expiration Date API: July 6, 2026
Check Box1: Yes