11 - Drawing Revisions.pdf

PDF 4 MB Posted

Attached to
Y1DA--9th Floor MH Renovation WBVAMC
Solicitation number
36C24425B0018
Issued by

About this file

These architectural drawings detail the renovation plans for the 9th Floor Mental Health area at the Wilkes-Barre VA Medical Center, Project #693-19-106. The comprehensive set of technical drawings includes floor plans, life safety plans, exterior elevations, roof plans, window details, interior elevations, finish schedules, and various architectural sections across multiple building levels. The drawings specify extensive renovation work for patient care spaces, including new wall configurations, window replacements, finish materials, ceiling treatments, and medical facility infrastructure modifications. Key design elements include specialized wall coverings, ligature-resistant fixtures, safety-focused room layouts, and medical-grade finishes tailored for a mental health treatment environment.

View the file

Other files

File Type Posted
36C24425B0018 0001.docx DOCX document
19a - RFI Responses 2.pdf PDF
19b - RFI Responses 3.pdf PDF
16 - Wilkes Barre PA Campus Site Plan Crane Locations.pdf PDF
21 - WD PA20250095 M4 03-21-2025.pdf PDF
19 - RFI Responses.pdf PDF
18a - Safety Health During Construction Policy 18S-15-346.pdf PDF
20 - Brand Name JA 9F MHU 20241804.pdf PDF
18 - Safety VA Directive 7715 Rev 092023.pdf PDF
22 - 852.219-75 MUST SIGN AND RETURN WITH BID.pdf PDF
36C24425B0018_4.docx DOCX document
17 - Noise and Vibration Control.pdf PDF
12a - ICRA Introductory Information and Instructions.pdf PDF
36C24425B0018_3.docx DOCX document
15 - M P Cut Sheets 693 19 106.pdf PDF
12b - G-009 ICRA.pdf PDF
13 - Structural Calcs 693 19 106 .pdf PDF
14 - Estimate - 693 19 106 M P Calcs.pdf PDF
12c - 17-H4 ICRA.pdf PDF
12e - 01-A4 ICRA.pdf PDF
12d - 01-A3 ICRA.pdf PDF
12 - ICRA Memo.pdf PDF
36C24425B0018_2.docx DOCX document
09 - Drawings Mechanical.pdf PDF
07 - Drawings General V2.pdf PDF
10 - Drawings Electrical.pdf PDF
06 - Drawings Fire Alarm and Protection.pdf PDF
10a - 17-E43 Revisions 2024-05-30.pdf PDF
08 - Drawings Plumbing.pdf PDF
03 - Drawings Hazardous Materials.pdf PDF
36C24425B0018 IFB Solicitation.pdf PDF
05a - Drawings Architectural 2.pdf PDF
01c - 107316 Aluminum Canopy System.pdf PDF
01d - 220523 Gen Duty Valves Plumb Piping.pdf PDF
36C24425B0018_1.docx DOCX document
05b - Drawings Architectural 3.pdf PDF
02 - Drawings General V1.pdf PDF
05c - A15 Revisions 2024-05-30.pdf PDF
05 - Drawings Architectural 1.pdf PDF
04 - Drawings Structural.pdf PDF
01 - Specifications Project 693-19-106 .pdf PDF
01b - 087100 Door Hardware.pdf PDF
01a - 066116 Solid Surfacing Fabrication.pdf PDF
01e - 221100 Fac Water Distr.pdf PDF
36C24425B0018.docx DOCX document
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

W X Y Z

CONFERENCE

OPEN

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

TOILET

COPY/LOCKERSSECRETARY

MECH

STORAGE

TOILET

OFFICE

ELEC

CLOSET

LOCKERS

STORAGE TOILET TELECOM

ROOM

OXYGEN

STORAGE

P la n N o rt h T ru e N o rt h

BASEMENT

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

KEY PLAN

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:5

A M

17-I11

LIFE SAFETY PLAN - WAREHOUSE RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 10 of 10 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L3/16" = 1'-0"

WAREHOUSE FLOOR PLAN - LIFE SAFETY

F4

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A1 ADDENDUM 1 06/28/2024

ZMiller Snapshot

ZMiller Snapshot

ZMiller Snapshot

ZMiller Text Box C2

ZMiller Text Box

OCCUPANT LOAD (OL) - LEVEL 01

ZMiller Line

ZMiller Text Box

NO SCALE

ZMiller

FRR

HZ

73.31 sf

ZMiller

FRR

HZ

27.41 sf

ZMiller

FRR

HZ

13.68 sf

ZMiller PolyLine

ZMiller PolyLine

ZMiller PolyLine

ZMiller PolyLine

ZMiller PolyLine

ZMiller PolyLine

ZMiller

FRR

HZ

1,574.31 sf

ZMiller PolyLine

ZMiller PolyLine

ZMiller PolyLine

ZMiller PolyLine

ZMiller PolyLine

ZMiller

MOE

EES-A-01

ZMiller

MOE

EES-B-01

ZMiller

MOE

EES-C-01

ZMiller Polygon

ZMiller Text Box

ED

ZMiller Polygon

ZMiller Text Box

ED

ZMiller Polygon

ZMiller Text Box

ED

ZMiller PolyLine

ZMiller Polygon

ZMiller Text Box

EX

ZMiller Polygon

ZMiller Text Box

EX

ZMiller Polygon

ZMiller Polygon

ZMiller Text Box

EA

ZMiller Polygon

ZMiller Polygon

ZMiller Text Box

EA

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Polygon

ZMiller Arrow

ZMiller Arrow

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Polygon

ZMiller Arrow

ZMiller Arrow

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Polygon

ZMiller Arrow

ZMiller Arrow

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Polygon

ZMiller Arrow

ZMiller Arrow

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Polygon

ZMiller Arrow

ZMiller Arrow

ZMiller

MOE

EATD (100 Feet Max) 98'-7 1/2"

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Arrow

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Arrow

ZMiller Workpoint

ZMiller Workpoint

ZMiller Ellipse

ZMiller Polygon

ZMiller Arrow

ZMiller Image

ZMiller Image

ZMiller Image

ZMiller Text Box

LEGEND - LIFE SAFETY PLANS

ZMiller PolyLine

ZMiller Snapshot

ZMiller Text Box Interior Exit Stairway (IES)

ZMiller Text Box Stairways

ZMiller Text Box

IES

ZMiller Rectangle

ZMiller Text Box Spaces open to the EAC

ZMiller Text Box Smoke Compartment (SC)

ZMiller Polygon

ZMiller Text Box

SC

ZMiller Polygon

ZMiller Text Box

SC

ZMiller Text Box Exit Access (EA)

ZMiller Line

ZMiller Line

ZMiller Text Box Exit Access Corridor (EAC) - Patient

ZMiller Line

ZMiller Line

ZMiller Text Box Exit Access Corridor (EAC) - Staff

ZMiller Polygon

ZMiller Text Box

EA

ZMiller Text Box Exit (EX)

Exit Discharge (ED)

ZMiller Text Box Travel Distances (Maximum) : New Health Care

ZMiller Text Box Exits & Exit Discharge

ZMiller Text Box

HEALTH CARE SUITES

PCS : Patient Care Sleeping Suites PCNS : Patient Care Nonsleeping Suites NPC : Non-Patient Care Suites

ZMiller

FRR

HAZ

ZMiller

FRR

HAZ

ZMiller PolyLine

ZMiller Polygon

ZMiller Text Box

ED

ZMiller Polygon

ZMiller Text Box

EX

ZMiller Text Box Exit Access (EA)

ZMiller Text Box Fire Barriers 2-Hour : 2FB 1-Hour : 1FB

Smoke Barriers 1-Hour : 1SB

Smoke Partitions 0-Hour : 0SP

ZMiller Line

ZMiller Line

ZMiller Line

ZMiller Line

ZMiller Line

ZMiller Line

ZMiller Line

ZMiller Line

ZMiller Line

ZMiller Line

ZMiller Line

ZMiller PolyLine

ZMiller PolyLine

ZMiller Text Box Fire-Resistance Rated (FRR) Assemblies

ZMiller Text Box Corridor Partitions Health Care Corridors & Suites (HCS) (Resists the Passage of Smoke ... Non-rated)

Shaft Enclosures 2-Hour : 2SE

FB+SB Combination 1-Hour : 1FSB

ZMiller Text Box

VERTICAL OPENING (VO) - SHAFTS, HOISTWAYS

HAZARDOUS AREA PROTECTION (HAZ)

FIRE EXTINGUISHER CABINET (FEC)

EXIT SIGNS

ZMiller Line

ZMiller Line

ZMiller Rectangle

ZMiller Text Box

ZMiller Rectangle

ZMiller Polygon

ZMiller Ellipse

ZMiller Line

ZMiller Workpoint

ZMiller Polygon

ZMiller Ellipse

ZMiller Line

ZMiller Workpoint

ZMiller Arrow

ZMiller Polygon

ZMiller Ellipse

ZMiller Line

ZMiller Workpoint

ZMiller Arrow

ZMiller Image

ZMiller Text Box 100 Feet (New Business / Existing Business) Boiler, Incinerator, Furnace Rooms [Mech Equip Room] : 50'

ZMiller Text Box Exit Access Travel Distance (EATD)

ZMiller PolyLine

ZMiller Text Box Dead End Corridors (DEC)

ZMiller Perimeter Measurement 26'-8"

ZMiller PolyLine

ZMiller Text Box 300 Feet (New Business / Existing Business)

ZMiller Text Box Common Path of Egress Travel (CPOETD)

ZMiller Text Box 50 Feet (New Business / Existing Business)

ZMiller Snapshot

ZMiller

FRR

HZ

311.23 sf

ZMiller Cloud

ZMiller Cloud

ZMiller Cloud

ZMiller Snapshot

ZMiller Snapshot

ZMiller Snapshot

Q R S T U V

C9-02

HAC

C9-04A

TOILET

C9-04

MEN'S

ST-2

STAIR

C9-09

ELEC

C9-11

QUIET ROOM

C9-C01

CORRIDOR

C9-13

SOILED UTILITY

C9-15A

TOILET

C9-15

MEN'S BARIATRIC

C9-14

MEN'S

C9-14A

TOILET

C9-12A

TOILET

C9-12

MEN'S C9-08

MEN'S BARIATRIC

C9-08A

TOILET

C9-07

OFFICE

C9-05

TOILET

C9-03

GROUP

COUNSELING ROOM

C9-C02

CORRIDOR

C9-06

MECHANICAL

C9-06A

ELEC

C9-01

EAST SUNROOM

01-A31D5

ROOF BELOW

C9-14

C9-15

C9-14A

C9-12A

C9-15A

C9-12

C9-10

C9-10

LAUNDRY

C9-11

F1

01-A37

01-A39

D7

01-A38

B3

B5

01-A36

D5

01-A36

A B B1 C

D

E

F

CB1BA

R E

F

-A

R E

F

-A

S1

SHAFT

S2

SOILED LINEN

CHUTE

C9-01 C9-00

C9-03C9-C02

C9-06

C9-06A

C9-07 C9-08

C9-04

01-A38

D3

01-A38

D1

13' - 5 1/4" 13' - 6 3/4" 14' - 8 1/4" 5' - 10 7/8" 9' - 9 1/8"

1C 1C 1C 1C

K

S8A.A

S3B.1

F1B

S6A

F1B

F1BF1B

01-A41

F1

01-A41

F4

01-A41

F7

01-A41

D7

OPP OPP OPP OPP

01-A42

F7

C9-16

J2 1

3'

EQ EQ

01-A41

F5

C9-04A

C9-02

C9-08A C9-05

01-A41

D7

SIM

01-A41

F7

SIM

01-A41

F5

SIM

01-A41

F4

SIM

01-A41

F1

SIM

92' - 3 3/4" 92' - 3 3/4"

C9-00

COURTYARD

F5

01-A36

OPPOPP OPP OPP

C7

01-A48

C5

01-A48

A. REFER TO 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE APPLICABLE.

B. REFER TO LARGE SCALE PLANS FOR ADDITIONAL INFORMATION AND

DIMENSIONS.

C. ALIGN NEW PARTITIONS WITH ADJACENT EXISTING PARTITIONS WHERE

NEW PARTITION EXTENDS IN THE SAME DIRECTION.

D. ALIGN CENTER OR FINISH FACE OF PARTITION WITH CENTER OF WINDOW

MULLION, UNLESS NOTED OTHERWISE.

E. PARTITIONS TO BE TYPE S3A, UNLESS NOTED OTHERWISE. FURRING

ALONG EXTERIOR WALLS TO BE S2B.1, UNLESS NOTED OTHERWISE. REFER

TO AE610 FOR PARTITION TYPE INFORMATION

F. REFER TO 01-A47 FOR WINDOW TYPES.

G. REFER TO 01-A40 FOR MILLWORK DETAILS.

H. REFER TO 01-A46 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND

FRAME DETAILS.

P la n N o rt h T ru e N o rt h

BLDG 01

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

KEY PLAN

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:1

A M

01-A14

FLOOR PLAN - 9TH FLOOR - EAST RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 14 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L3/16" = 1'-0"

9TH FLOOR PLAN - EAST

F1

1 INFILL OPENING TO MATCH ADJACENT CONSTRUCTION

2 NEW GLAZING IN EXISTING FRAME. MATCH LAYOUT TO EXISTING WINDOWS.

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A1 ADDENDUM 1 06/28/2024

A1

ALIGN

L1-111

CONFERENCE

L1-103

OPEN OFFICE

L1-110

OFFICE

L1-109

OFFICE

L1-108

OFFICE

L1-107

OFFICE

L1-105

TOILET

L1-104

COPY/LOCKERS

L1-102

SECRETARY

L1-112

MECH

L1-100

STORAGE

L1-100G

TOILET

L1-100H

OFFICE

L1-100A

ELEC

L1-102A

CLOSET

17-A32F5

17-A32

D5

L1-12

L1-07

L1-06L1-01

01-A39

F2

01-A34

01-A34

D7

L1-10

L1-09

L1-08

L1-11

W X Y Z

27' - 0" 26' - 0" 15' - 0"

/4

L1-05

3'

1/ 2"

/4

/8

9'

7/ 8"

9'

7/ 8"

9'

7/ 8"

6'

1/ 4"

7'

/2

3' - 3" 1' - 2 3/4"

2'

6'

7' - 0"

L1-00G

L1-00A

L1-00B

L1-00C

L1-00D

3'

2'

L1-02A

L1-100J

LOADING DOCK

L1-100F

LOCKERS

1'

/4

L1-106

TOILET

L1-02

100 SF

L1-100E

TELECOM ROOM

L1-00E

9' - 4 3/4" 5' - 0" 10' - 11" 13' - 6" 9' - 6 1/2"

6' - 8" 5' - 0 5/8"

14' - 4 7/8"

EQ 12' - 8" EQ

1' - 9"

3'

3'

3'

/8

7'

/4

3'

/8

HD5

S3B.1

S2B.1

S2B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S2B.1

01-A41

D5

S2B.1

L1-101

STORAGE

7' - 5 1/8"

B7

L1-001

OXYGEN STORAGE

1'

/4

S3B.1

S3A.1 S3A.1

S6A

L1-03

D5

01-A40 8'

/8

F5

01-A40

A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

B. REFER TO ENLARGED FLOOR PLANS FOR ADDITIONAL INFORMATION AND

DIMENSIONS.

C. ALIGN NEW PARTITIONS WITH ADJACENT EXISTING PARTITIONS WHERE

NEW PARTITION EXTENDS IN THE SAME DIRECTION.

D. ALIGN CENTER OR FINISH FACE OF PARTITION WITH CENTER OF WINDOW

MULLION, UNLESS NOTED OTHERWISE.

E. PARTITIONS TO BE TYPE S3B, UNLESS NOTED OTHERWISE. FURRING

ALONG EXTERIOR WALLS TO BE S2B.1, UNLESS NOTED OTHERWISE.

F. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL

INFORMATION.

P la n N o rt h T ru e N o rt h

BASEMENT

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

KEY PLAN

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:5

A M

17-A15

FLOOR PLAN - WAREHOUSE RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 15 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L3/16" = 1'-0"

WAREHOUSE FLOOR PLAN

F4

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

OPEN TO

BELOW

S T U V

B5

01-A36

D5

01-A36

105' - 6 3/4"

F5

01-A361

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. PROVIDE 1/2"/FT. TAPERED INSULATION AT ROOF CURBS AND AT

EQUIPMENT WHICH EXCEEDS 18 INCHES IN WIDTH.

ROOF LEGEND

TPO ROOF OVER SLOPED INSUALTION (1/4" PER FOOT MIN)

TPO ROOF OVER SLOPED INSUALTION (1/8" PER FOOT MIN)

P la n N o rt h T ru e N o rt h

BLDG 01

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

KEY PLAN

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:1

A M

01-A22

ROOF PLAN - 9TH FLOOR RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 22 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1 PROVIDE ROOF CRICKET FOR NEW ROOFTOP MECHANICAL EQUIPMENT,

TYP

2 ROOF DRAIN TO TIE INTO EXISTING SYSTEM PER MECHANICAL

3/16" = 1'-0"

9TH FLOOR ROOF PLAN

F4

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A1 ADDENDUM 1 06/28/2024

A

LI

G N

ALIGN

ALIGN

A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

B. REFER TO FINISH SCHEDULE FOR MORE INFORMATION.

C. ALIGN ALL WALL TILE JOINTS WITH FLOOR TILE JOINTS, UNLESS NOTED

OTHERWISE

D. FLOOR FINISH MATERIAL AND/OR PATTERN SHALL BE INSTALLED UNDER

TOE KICKS OF CASEWORK/MILLWORK, UNDER OPEN COUNTERTOPS, AND

UNDER EQUIPMENT.

E. FLOOR MATERIAL/COLOR TRANSITIONS TO ALIGN WITH ROOM SIDE OF

DOOR STOP, UNLESS NOTED OR SHOWN OTHERWISE.

F. INSTALL TRANSITION STRIPS AT ALL FLOOR FINISH MATERIAL CHANGES,

UNLESS NOTED OTHERWISE.

G. END CAP GUARDS ARE TO ALL BE ECG-1, UNLESS NOTED OTHERWISE.

Q R S T U V

C9-02

HAC

C9-04A

TOILET

C9-04

MEN'S

ST-2

STAIR

C9-09

ELEC

C9-11

QUIET ROOM

C9-C01

CORRIDOR

C9-13

SOILED UTILITY

C9-15A

TOILET

C9-15

MEN'S BARIATRIC

C9-14

MEN'S

C9-14A

TOILET

C9-12A

TOILET

C9-12

MEN'S

C9-08

MEN'S BARIATRIC

C9-08A

TOILET

C9-07

OFFICE

C9-05

TOILET

C9-03

GROUP

COUNSELING ROOM

C9-C02

CORRIDOR

C9-06

MECHANICAL

C9-06A

ELEC

C9-01

EAST SUNROOM

ROOF BELOW

ROOF BELOW

C9-10

LAUNDRY

R E

F

-A

R E

F

-A

C9-00

COURTYARD

1'

1'

01-A35

E1

F1

14' - 0"7' - 0"

FINISH LEGEND

PT-1

PT-2

TRF-1

PVR-1HSF-1

WSF-2 (LIGHT)

WSF-1 (DARK)

RES-6A

LVT-1

P la n N o rt h T ru e N o rt h

BLDG 01

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

KEY PLAN

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:1

A M

01-A27

FINISH PLAN - 9TH FLOOR - EAST RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 27 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L3/16" = 1'-0"

9TH FLOOR FINISH PLAN - EAST

F1

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

8TH FLOOR

80' - 11 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11TH FLOOR

115' - 4 3/4"

ABCDEFGHJKLMN

R E

B

-A

R E

B

-A

FOLDED ELEVATION

A R

E A

O F

W O

R K

R E

B

-A

22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"17' - 3"4' - 9"5' - 1"16' - 11"

1B 1B

8TH FLOOR

80' - 11 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11TH FLOOR

115' - 4 3/4"

A B C D E F G H J K L M N

R E

F

-A

R E

F

-A

A R

E A

O F

W O

R K

F4

01-A37

22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 17' - 3" 4' - 9" 5' - 1" 16' - 11"

1B.1 1B 1C 1C 1C 1C 1C 1C 1C 1C

8TH FLOOR

80' - 11 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11TH FLOOR

115' - 4 3/4"

9 10 11 12 13 14

A R

E A

O F

W O

R K

22' - 0" 23' - 0" 16' - 0" 10' - 0" 17' - 0"

1D.1

A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT

ARE APPLICABLE.

B. EXTERIOR WINDOW PROFILES FOR SOUTH AND WEST ELEVATIONS ARE

REPRESENTATIVE OF INFORMATION FROM DRAWINGS PROVIDED TO

VALHALLA FROM VHA COR ON 02/10/2020 FROM VHA PROJECT #693-13-111.

WINDOW SIZES HAVE BEEN MODIFIED TO MATCH EXISTING OPENINGS AS

UNDERSTOOD BY VALHALLA AND ARE TO BE VERIFIED IN FIELD.

C. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL

INFORMATION.

EXTERIOR ELEVATION LEGEND

NEW LINE TYPE

EXISTING LINE TYPE

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:2

A M

01-A30

EXTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 30 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1/8" = 1'-0"

NORTH ELEVATION - WEST

B1

1/8" = 1'-0"

SOUTH ELEVATION - WEST

F1

1/8" = 1'-0"

WEST ELEVATION

D5

1 INSTALL NEW LAMINATED GLAZING AND SPANDREL PANELS IN EXISTING

WINDOW FRAME TO MATCH EXISTING LAYOUT. WINDOWS TO HAVE

INTEGRAL BLINDS BETWEEN LAYERS OF GLAZING.

A1

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

BASEMENT

-14' - 0"

H

BASEMENT

-14' - 0"

TUV

GL

EXTERIOR ELEVATION LEGEND

NEW LINE TYPE

EXISTING LINE TYPE

A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

B. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL

INFORMATION.

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:5

A M

17-A32

EXTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 32 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1/8" = 1'-0"

EAST WAREHOUSE ELEVATION

F5

1/8" = 1'-0"

NORTH WAREHOUSE ELEVATION

D5

1 STEEL STAIR, GUARD AND HANDRAIL

2 NEW AIR HANDLING UNIT; RE MECHANICAL

3 EXISTING AIR HANDLING UNIT

4 INSTALL WINDOW PANE IN DEMOLISHED EXHAUST FAN OPENING. MATCH

EXISTING WINDOW DESIGN AND GLAZING TYPE

OPEN TO

C9-27A

OPEN TO

C9-27

18 34 24

36 34 24

36 34 24

36 18 12

36 30 12

18 30 12

8' - 4 1/2"

F

F 900

34 25

34 25

A. REFER TO 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE APPLICABLE.

B. REFER TO 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING HEIGHTS OF

FIXTURES AND ACCESSORIES

C. REFER TO 01-A40 FOR MILLWORK DETAILS

D. REFER TO 01-A46 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND

FRAME DETAILS

E. REFER TO 01-A47 FOR WINDOW TYPES

F. REFER TO 01-A50 FOR FINISH SCHEDULE AND LEGEND.

36 34 24

12 34 24

36 18 12

12 30 12

2' - 3"

F

F900

34 25

32 25

34 25

34 25

FINISH LEGEND

SCHEDULED PNT

WP-1SCHEDULED RWC

PT-2/PT-3

PER DETAIL ON 01-A49

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:2

A M

01-A33

INTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 33 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

3/8" = 1'-0"

C9-27 - SOUTH ELEVATION

C2

3/8" = 1'-0"

C9-68A - EAST ELEVATION

F7

3/8" = 1'-0"

C9-65 - WEST ELEVATION

E73/8" = 1'-0"

C9-64 - SOUTH ELEVATION

E5

3/8" = 1'-0"

C9-64 - EAST ELEVATION

F5

3/8" = 1'-0"

C9-33 - WEST ELEVATION

C7

3/8" = 1'-0"

C9-27A - NORTH ELEVATION

E2

3/8" = 1'-0"

C9-27 - NORTH ELEVATION

B2

3/8" = 1'-0"

C9-15A - EAST ELEVATION

B7

3/8" = 1'-0"

C9-15A - NORTH ELEVATION

C5

3/8" = 1'-0"

C9-15A - WEST ELEVATION

B5

3/8" = 1'-0"

C9-42 - SOUTH ELEVATION

F2

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

T U V

D5

01-A36

4' - 1 1/8"22' - 0"20' - 7 1/2"

F5

01-A36

01-A43

B6

01-A44

F1

01-A44

C1

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11121314 B5

01-A36

01-A44

F5

01-A43

D3

01-A44

F5

OPP

01-A43

D6 C7

01-A48

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION

REGARDING INTERIOR WALL CONSTRUCTION.

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11121314 B5

01-A36

01-A44

C5

01-A43

F3

01-A43

F6

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:2

A M

01-A36

BUILDING SECTIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 36 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1/4" = 1'-0"

BUILDING SECTION 1 @ EAST SUNROOM

B5

1/4" = 1'-0"

BUILDING SECTION 2 @ COURTYARD

D5

1/4" = 1'-0"

BUILDING SECTION 2 @ EAST SUNROOM

F5

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A1 ADDENDUM 1 06/28/2024

1 WALL MOUNTED, LIGATURE RESISTANT TELEVISION ENCLOSURE

BASEMENT

01-A43

D1

01-A48

F5

SIM

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

01-A43

F1

01-A48

F3

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION

REGARDING INTERIOR WALL CONSTRUCTION.

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

01-A48

E3

01-A48

F3

SIM

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:3

A M

01-A37

WALL SECTIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 37 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

3/4" = 1'-0"

SECTION AT NEW WAREHOUSE STOREFRONT ENTRY

F63/4" = 1'-0"

SECTION AT DAY/TV - SOUTH WALL

F4

1 NEW WINDOW SYSTEM. WINDOWS TO HAVE INTEGRAL BLINDS BETWEEN

LAYERS OF GLAZING AND INTERIOR LAYER SHALL BE LAMINATED GLASS

2 NEW LAMINATED GLAZING IN EXISTING WINDOW FRAME. WINDOWS TO

HAVE INTEGRAL BLINDS BETWEEN LAYERS OF GLAZING.

3 SCHEDULED CEILING, RE: REFLECTED CEILING PLAN

4 EXISTING EXTERIOR CONCRETE WALL (R-VALUE = 1)

5 EXISTING CONCRETE FLOOR STRUCTURE

6 NEW STOREFRONT SYSTEM AND DOOR TO ALIGN WITH EXISTING WINDOWS

AND MULLIONS

7 STEEL GUARD

8 EXISTING EXTERIOR MASONRY WALL (R-VALUE = 2.38)

3/4" = 1'-0"

SECTION AT MEN'S PATIENT ROOM C9-13 - NORTH WALL

F1 3/4" = 1'-0"

SECTION AT PATIENT TOILET ROOM C9-23A - SOUTH WALL

F3

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

G N

A

LI

G N

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO SHEET 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING

HEIGHTS OF FIXTURES AND ACCESSORIES.

D. ALIGN NEW WALLS WITH ADJACENT EXISTING WALLS WHERE NEW WALL

EXTENDS IN THE SAME DIRECTION.

E. ALIGN CENTER OF DEMISING WALLS OR FINISH FACE OF CHASE WALLS

WITH CENTER OF WINDOW MULLION, UNLESS NOTED OTHERWISE.

F. PARTITIONS TO BE TYPE S3A, UNLESS NOTED OTHERWISE. FURRING

ALONG EXTERIOR WALLS TO BE S2B.1, UNLESS NOTED OTHERWISE.

G. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL

INFORMATION.

C

C9-68A

TOILET

C9-66A

TOILET

6' - 7 3/8" 1' - 5" 11 1/8"

4'

/8

3'

4'

/8

01-A33 F7

9 5/8"

S3B.1

S3B.1

S3B.1

S3B.1 S3B.1

S3B.1

1'

/4

3'

S3B.1

S3B.1

S3B.1

S3B.1

A5196

A5112

A5140

A5081

A5074

A1086

A5081

A5074

A1086

A5140

A5112

A5196

C

C9-67A

TOILET

6' - 3 5/8" 9 3/4"

5' - 0" 1' - 4 1/2"

4'

1/ 4"

3'

3'

0"

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

8"

5'

S3B.1 S3B.1

S3B.1

S3B.1

S3B.1 A5140

A5081

A5074

A1086

A5196

A5112

F

C9-49A

TOILET

7' - 10 1/8" 4' - 0"

S8A.A

S3B.1

3'

5'

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

A5196

A5112

A1086

A5140

A5074

A5081

G

C9-43A

TOILET

C9-42

STAFF TOILET

S3B.1

S3B.1

S3B.1

S6A

S6A

6' - 8 1/8"

4'

/8

6'

/2

3'

"1' - 0 1/8"

01-A33

F2

4' - 0"

A5140

A5196

A5112

A5140

A5081

A5074

A1086

A1086

A5074

A5081A5112

A5196

A5140

C9-44A

TOILET

C9-41A

TOILET

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1S3B.1

S3B.1

S3B.1

3'

1/ 2"

3'

4'

/8

3'

9 3/4"

3' - 0"

3' - 0"

11" 9 3/4"

S3B.1

A5196

A5112

A1086

A5140

A5074

A5081

A5081 A5074 A1086

A5196

A5140

A5112

L M

F3

01-A37

C9-24A

TOILET

C9-25A

TOILET

S3B.1

S3B.1

S6A.A21

S3B.1

S3B.1

3'

7/ 8"

3'

/8

4'

/8

2'

7 1/2"

5' - 2 7/8" 1' - 5" 6 3/8"

1' - 0 1/8"

3' - 2 7/8"

S3B.1

S3B.1

S3B.1

S3B.2

S6A

S3A.A21

A5196

A5112

A5140

A1086

A5074

A5081

A5140

A5112

A5196

A5081

A5074

A1086

O

C9-20A

TOILET

C9-18A

TOILET

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1 S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1 F1B

S3B.1

3' - 0"

9 3/4" 4' - 7" 1' - 9 3/8" S3B.1

F1B

9 3/4"

3'

/2

3'

4'

/4

3'

3' - 0"

A5081

A5074

A1086

A5140

A5196

A5112

A5081

A5074

A1086

A5140

A5196

A5112

Q

C9-15A

TOILET

5'

/4

3'

1' - 0 1/8" 4' - 3 1/4"

S3B.1

S3B.1 S3B.1

S3B.1

01-A33

C5

B7B5

01-A41

B5

A5196

A5112

A1086

A5081

A5140

A5074

Q

C9-12A

TOILET

C9-14A

TOILET

S3B.1

S3B.1

S3B.1

S3B.1S3B.1

S3B.1

S3B.1

S3B.1

S3B.1 S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

3'

1/ 4"

3'

4'

/8

3'

/4

1' - 5"

3' - 0"

3' - 0"

S6A

S6A

A5140 A5081

A5074 A1086

A5112

A5196

A5081

A5074

A1086

A5112

A5196

A5140

S

C9-07

OFFICE

C9-05

TOILET

C9-08A

TOILET

C9-06

4'

6'

/8

S3B.1

S3B.1S3B.1

5' - 0" 1' - 4 1/2" 8' - 4 1/4"

6' - 9 1/4" 1' - 8 1/2"

2'

7'

/2

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1 S3B.1

S3B.1

S3B.1

S6A

A5196

A5140

A5112

A1086

A5074

A5081

A5081

A5074

A1086

A5196

A5140

A5112

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:3

A M

01-A38

ENLARGED FLOOR PLANS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 38 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-66A AND C9-68A

F7

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-67A

B7

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-49A

D7

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-42 AND C9-43A

F5

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-41A AND C9-44A

D5

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-24A AND C9-25A

F33/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-18A AND C9-20A

F1

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-15A

D33/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-12A AND C9-14A

D1

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-05 AND C9-08A

B3

TOILET ROOM ACCESSORY SCHEDULE

JSN DESCRIPTION REMARKS

A5196 DISPENSER, TOILET TISSUE, PSYCHIATRIC

A1086 MIRROR, SAFETY, PSYCHIATRIC

A5081 DISPENSER, PAPER TOWEL, PSYCHIATRIC

A5074 SOAP DISH, RECESSED, SS, PSYCHIATRIC

A5109 GRAB BAR, 1-1/4" DIA, SS, 2 WALL, W/C ACCESSIBLE

A5140 HOOK, GARMENT, SECURITY

A1

ALIGN

O

C9-22

SERVING KITCHEN

01-A34

F4

F2

F5

S3B.1

2' - 1"

S3B.1

S3B.1

S3B.1

4'

/8

B3

01-A40

L M

C9-35A

LOCKERS

S3B.1

1'

5'

/8

3'

3'

1"

2' - 4 3/4"

1' - 11 3/8" 7' - 8" 1' - 6 5/8" 2' - 4 1/4"

120°

S3B.1 S3B.1S3B.1F1BS3B.1

S3B.1

1' - 6"

S3B.1

01-A34

C5

C7C4

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO SHEET 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING

HEIGHTS OF FIXTURES AND ACCESSORIES.

D. ALIGN NEW WALLS WITH ADJACENT EXISTING WALLS WHERE NEW WALL

EXTENDS IN THE SAME DIRECTION.

E. ALIGN CENTER OF DEMISING WALLS OR FINISH FACE OF CHASE WALLS

WITH CENTER OF WINDOW MULLION, UNLESS NOTED OTHERWISE.

F. PARTITIONS TO BE TYPE S3A, UNLESS NOTED OTHERWISE. FURRING

ALONG EXTERIOR WALLS TO BE S2B.1, UNLESS NOTED OTHERWISE.

G. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL

INFORMATION.

T

C9-02

HAC

C9-04A

TOILET

S2B.1

S3B.1

1' - 4 7/8" 3' - 7 1/4" 3' - 6 3/8"

6'

/4

4'

/8

S6A

S3B.1

S3B.1

S3B.1

S3B.1

A1086

A5196

A5074

A5081

A5140

A5112

F6

01-A37

G

J

7' - 1 3/4" 4' - 0" F1

01-A40

D

01-A33 F5

F1

01-A40

2'

S4

R

' - 1

3'

2' - 8 3/8"

5' - 5 13/16"

2' - 6"

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:4

A M

01-A39

ENLARGED FLOOR PLANS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 39 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1 INFILL EXISTING WINDOW OPENING WITH WALL TO MATCH ADJACENT

3/8" = 1'-0"

ENLARGED FLOOR PLAN - C9-22

F4 3/8" = 1'-0"

ENLARGED FLOOR PLAN - C9-35A

F7

3/8" = 1'-0"

ENLARGED FLOOR PLAN - C9-02 AND C9-03

D7

3/8" = 1'-0"

ENLARGED WAREHOUSE STAIR PLAN

F2

3/8" = 1'-0"

ENLARGED PLAN - C9-27 DESK

D4

3/8" = 1'-0"

ENLARGED PLAN - C9-64 DESK

B4

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A1 ADDENDUM 1 06/28/2024

TOILET ROOM ACCESSORY SCHEDULE

JSN DESCRIPTION REMARKS

A5196 DISPENSER, TOILET TISSUE, PSYCHIATRIC

A1086 MIRROR, SAFETY, PSYCHIATRIC

A5081 DISPENSER, PAPER TOWEL, PSYCHIATRIC

A5074 SOAP DISH, RECESSED, SS, PSYCHIATRIC

A5109 GRAB BAR, 1-1/4" DIA, SS, 2 WALL, W/C ACCESSIBLE

A5140 HOOK, GARMENT, SECURITY

2"

60°

1' - 0"

7'

123200-A

123200-E

2"

4"

096513-A

123200-E

123200-A

061000-D

123600-A

123600-B

123200-G

061000-C

123600-A

061000-D

123600-C

096513-A

061000-C

2'

0"

2' - 1"

A. REFER TO FINISH LEGEND AND FINISH SCHEDULE FOR SPECIFIC FINISH

INFORMATION.

B. ALL MILLWORK/ CASEWORK CONSTRUCTION SHALL MEET AWI PREMIUM

STANDARDS, UNLESS NOTED OR SPECIFIED OTHERWISE.

C. ALL EXPOSED MILLWORK/ CASEWORK SURFACES SHALL BE FINISHED W/

PLASTIC LAMINATE TO MATCH ADJACENT PLASTIC LAMINATE SURFACES,

UNLESS NOTED OTHERWISE.

D. ALL CASEWORK INTERIORS SHALL BE WHITE MELAMINE, UNLESS NOTED

OTHERWISE.

E. ALL FILLER PANELS SHALL BE 1-1/2 INCH WIDE MINIMUM, FINISHED TO

MATCH ADJACENT FINISH SURFACES, AND SCRIBED TO FIT ADJACENT

WALL, UNLESS NOTED OTHERWISE.

F. ALL BACKSPLASH FINISHES SHALL MATCH COUNTERTOP MATERIAL AND

FINISH, UNLESS NOTED OTHERWISE. PLASTIC LAMINATE

SIDE/BACKSPLASHES TO HAVE SELF EDGE LAMINATE, UNLESS NOTED

OTHERWISE.

G. CONTRACTOR SHALL APPLY CLEAR MILDEW RESISTANT SILICONE SEALANT

WHERE BACKSPLASH MEETS WALL AND COUNTERTOP.

H. THE UNDERSIDE OF COUNTERTOPS WITH KNEE OPENINGS, MUST HAVE A

WHITE MELAMINE FINISH, UNLESS NOTED OTHERWISE.

I. WATER AND SUPPLY DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL

BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST

CONTACT. THERE SHALL BE NO SHARP OF ABRASIVE SURFACES UNDER

LAVATORIES AND SINKS.

4"

096513-A

123200-A

061000-D

123600-A

123600-B

123200-G

061000-C

224000-D

1'

1' - 6"

3"

123200-A

061000-C

9TH FLOOR

92' - 3 3/4"

1'

092216-A

088000-B

123600-C

096513-A

061000-D

123200-A

092216-A092900-A

123600-A

061000-D

123600-C

096513-A

061000-C

2'

0"

2' - 1"

092900-A

092216-A

TY

P

R 1/4"

1' - 0"

3 1/4"

9TH FLOOR

92' - 3 3/4"

O

1' - 0"

2' - 0"

2'

0"

S3A

123600-A

061000-D

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:4

A M

01-A40

MILLWORK SECTIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 40 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L1 1/2" = 1'-0"

CASEWORK SECTION - CDS 301 & 302

F3 1 1/2" = 1'-0"

CASEWORK SECTION - CDS 211 & 222

F71 1/2" = 1'-0"

CASEWORK SECTION - CDS 900

F5

061000-C WOOD BLOCKING

061000-D PLYWOOD SHEATHING

088000-B SECURITY GLAZING

092216-A METAL STUDS, RE WALL TYPE

092900-A GYPSUM BOARD

096513-A RESILIENT BASE, RE FINISH SCHEDULE

123200-A PLASTIC LAMINATE CASEWORK

123200-E ADJUSTABLE SHELF

123200-G WIRE PULL

123600-A PLASTIC LAMINATE COUNTERTOP

123600-B PLASTIC LAMINATE BACKSPLASH

123600-C COUNTER BRACKET

224000-D HAND SINK, RE PLUMBING

1 1/2" = 1'-0"

CASEWORK SECTION - CDS 152

D7

1 1/2" = 1'-0"

CORRIDOR BENCH DETAIL

B7

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A1 ADDENDUM 1 06/28/2024

1 1/2" = 1'-0"

CASEWORK SECTION - NURSE STATION

F1

1 1/2" = 1'-0"

WAREHOUSE RECEPTION COUNTER

D5

A1

1 1/2" = 1'-0"

DETAIL @ COILING DOOR COUNTER

B3

9TH FLOOR

92' - 3 3/4"

072200-B

077600-A

092900-B

092216-B

076000-A

079200-A 088000-A

084413-A

079200-C

061000-C 075423-A

072200-C

072200-B

6"

PER RCP

079200-C

084413-A

088000-A

079200-A

092900-A

092216-A

095100-A

6"

PER RCP

E Q

E Q

084413-A

079200-C 079200-A

092216-A

092900-A

088000-A

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION

REGARDING INTERIOR WALL CONSTRUCTION.

9TH FLOOR

92' - 3 3/4"

061000-B

096513-A

092900-A

072113-B

076000-A

079200-A088000-A

084413-A

079200-C

061000-C

072200-A

9TH FLOOR

92' - 3 3/4"

2"

061000-B

096513-A

092900-A

072113-B

092216-A

079200-A 088000-A

084413-A

079200-C

061000-C

076000-A

051200-E

072200-A

9TH FLOOR

92' - 3 3/4"

072200-B

092216-B

092900-B

076000-A

079200-A 088000-A

084413-A

079200-C

061000-C

076000-A

033000-G

072200-C

075423-A

072200-D

9TH FLOOR

92' - 3 3/4"

V

072200-B

092216-B

092900-B

076000-A

079200-A 088000-A

084413-A

079200-C

061000-C

075423-A

072200-C

072200-D

077600-A

KEYNOTES ######-A

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:4

A M

01-A43

SECTION DETAILS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 43 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1 1/2" = 1'-0"

DETAIL @ COURTYARD SOUTH STOREFRONT SILL

D31 1/2" = 1'-0"

CEILING DETAIL AT WAREHOUSE STOREFRONT

D1

1 1/2" = 1'-0"

SECTION DETAIL - CEILING TO MULLION

F1

033000-G CONCRETE WALL

051200-E STEEL PLATE, RE STRUCTURAL

061000-B FIRE-RETARDANT-TREATED PLYWOOD SHEATHING

061000-C WOOD BLOCKING

072113-B EXTRUDED-POLYSTYRENE BOARD INSULATION WITH TAPED AND

SEALED SEAMS

072200-A RIGID ROOF INSULATION

072200-B TAPERED ROOF INSULATION

072200-C ROOF CANT STRIP

072200-D GLASS MAT, WATER-RESISTANT GYPSUM ROOF BOARD

075423-A THERMOPLASTIC POLYOLEFIN (TPO) ROOFING SYSTEM

076000-A PREFINISHED SHEET METAL FLASHING

077600-A ROOFTOP TURF PAVER SYSTEM

079200-A JOINT SEALANT

079200-C BACKER ROD AND SEALANT

084413-A GLAZED ALUMINUM CURTAIN WALL

088000-A GLAZING PER GLAZING SCHEDULE

092216-A METAL STUDS, RE WALL TYPE

092216-B METAL HAT CHANNEL, RE WALL TYPE

092900-A GYPSUM BOARD

092900-B GLASS MAT GYPSUM BOARD

095100-A ACOUSTICAL PANEL CEILING, RE FINISH SCHEDULE

096513-A RESILIENT BASE, RE FINISH SCHEDULE

1 1/2" = 1'-0"

DETAIL @ SUNROOM SOUTH STOREFRONT SILL

F3 1 1/2" = 1'-0"

DETAIL @ SUNROOM NORTH STOREFRONT SILL

F6

1 1/2" = 1'-0"

DETAIL @ COURTYARD NORTH STOREFRONT SILL

D6

1 1/2" = 1'-0"

DETAIL @ COURTYARD EAST SUNROOM SILL

B6

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A1 ADDENDUM 1 06/28/2024

1 INFILL EXISTING WINDOW OPENING WITH WALL TO MATCH ADJACENT

A1

A1

A1

A1

A1

A1

R O

9'

8"

5'

0"

1'

RO

8' - 9 1/2"

EQ EQ

4 8

1/

2"

B

5'

0"

1'

R O

9'

8"

EQ EQRO

9' - 0"

8 4

1/

2"

R O

9'

8"

5'

0"

1'

EQ EQ

RO

8' - 8 1/2"

C

8 6

1/

2"

1'

5'

0"

8"

R O

9'

3' - 10 3/4" EQ 3' - 10 3/4"

RO

11' - 8 3/8"

D

6 8 6

1/

2"

1'

5'

0"

8"

R O

9'

EQ EQ

RO

7' - 5 1/2"

E

8 8

1/

2"

8"

R O

9'

1'

5'

0"

EQ EQ EQ

RO

12' - 2 1/8"

F

6 8 6

1/

2"

S1

26' - 6"

SCHEDULE

PER DOOR1' - 8"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"

SCHEDULE

PER DOOR

7'

2'

/2

4"

S2

7'

2'

31' - 10 3/4"

6' - 4" 2' - 4 1/2" 11"

SCHEDULE

PER DOOR 2' - 5 3/4"

SCHEDULE

PER DOOR 11" 2' - 4 1/2" 6' - 4" 3' - 2"

1 11

ALIGN WITH CENTER OF

PARTITION BEYOND

S3

3'

4'

EQ EQ

6' - 6"

3'

4'

4' - 0"

S4

/8

V

IF

P E

R D

O O

R S

C H

E D

U

LE

G

V

IF

4'

/2

8' - 6"

17' - 0" VIF

V

IF

8'

/8

2' - 6"

SCHEDULE

PER DOOR

EQ EQ

3'

R O

7'

/8

5'

/4

RO

8' - 0"

EQ EQ

H

2 2

S2.1

3' - 0"

7'

2'

4"

4 4 4 4 4 4 4

5555555

7'

/2

V

IF

V

IF

2'

18' - 11 1/4" VIF

2' - 3 1/2" 3' - 7 3/4" 2' - 10" 1' - 10" 1' - 10" 3' - 9"

1B

FOR TYPE 1B.1, PANELS

TO BE LOUVERS PER

MECHANICAL DRAWINGS

5'

/8

8'

/8

V

IF

V

IF

2'

/8

3' - 8" 2' - 10" 1' - 10" 1' - 10" 3' - 9"

16' - 8" VIF

5" 5"

5"

444444

5 5 5 5 5

1C

5'

V

IF

2'

V

IF

7'

/2

5' - 1"

7' - 8" VIF

5"

5" 5"

1D.1

4 4

V

IF

2'

M A

T C

H A

D

JA

C E

N T

6'

/4

V

IF

8' - 6" VIF

EQ EQ

A D

JA

C

E N

T

M A

T C

H

J

44 4 4

3' - 4" 3' - 9" 3' - 9" 3' - 9" EQ EQ 3' - 9" 3' - 9" 3' - 9" 3' - 10"

PER DOOR SCHEDULE

36' - 10 1/2"

4'

/8

3'

7/ 8"

1/

2"

P E

R D

O O

R S

C H

E D

U

LE

6 6 6 6

6666666666

6 6 6 6

K

A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT

ARE APPLICABLE.

B. EXTERIOR WINDOW PROFILES FOR SOUTH AND WEST ELEVATIONS ARE

REPRESENTATIVE OF INFORMATION FROM DRAWINGS PROVIDED TO

VALHALLA FROM VHA COR ON 02/10/2020 FROM VHA PROJECT #693-13-111.

WINDOW SIZES HAVE BEEN MODIFIED TO MATCH EXISTING OPENINGS AS

UNDERSTOOD BY VALHALLA AND ARE TO BE VERIFIED IN FIELD.

4'

3'

8' - 0"

EQ 3' - 4" EQ

11 1

S5

8 8

6 6

B1

RO

9' - 0"

EQ EQ

R O

9'

8"

5'

0"

1'

1/

2"

L

/8

V

IF

V

IF

4'

/2

EQ EQ EQ EQ

17' - 0" VIF

E Q

E Q 2 2

2 2

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:4

A M

01-A47

WINDOW FRAME TYPES RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 46 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

GLAZING TYPE SCHEDULE

TYPE IMAGE DESCRIPTION

1 3/8" POLYCARBONATE, CLEAR

2 DOUBLE PANED, LOW-E, ARGON FILLED GLAZING, CLEAR

3 7/16" LAMINATED SPANDREL PANEL

DOUBLE PANED, LOW-E, ARGON FILLED GLAZING WITH 3/8"

POLYCARBONATE ON INTERIOR, CLEAR

INSULATED SPANDREL GLAZING UNIT, DOUBLE PANED, ARGON

FILLED

DOUBLE PANED, LOW-E, ARGON FILLED GLAZING WITH 3/8"

POLYCARBONATE BOTH PANES, CLEAR

3/8" POLYCARBONATE, BOD: LUMICOR LUMIFORM NATURAL -

COASTAL

OPERABLE PANE, GLAZING TYPE TO MATCH REST OF SYSTEM,

BOD: KAWNEER GLASSVENT WINDOWS FOR CURTAIN WALL

STOREFRONT/CURTAIN WALL SCHEDULE

TYPE FRAME TYPE HEAD DETAIL JAMB DETAIL SILL DETAIL

1B 2 E3/01-A48 E3/01-A48 SIM F3/01-A48

1B.1 2 E3/01-A48 E3/01-A48 SIM F3/01-A48

1C 2 E3/01-A48 E3/01-A48 SIM F3/01-A48

1D.1 2 E3/01-A48 E3/01-A48 SIM F3/01-A48

A 1 C5/01-A44 RE: 01-A41 RE: 01-A43

B 1 C5/01-A44 RE: 01-A41 RE: 01-A43

B1 1 F5/01-A44 RE: 01-A41 RE: 01-A43

C 1 F5/01-A44 RE: 01-A41 RE: 01-A43

D 1 C1/01-A44 RE: 01-A41 RE: 01-A43

E 1 C1/01-A44 RE: 01-A41 RE: 01-A43

F 1 C1/01-A44 RE: 01-A41 RE: 01-A43

G 1 E7/01-A48 E5/01-A48 F5 & F7/01-A48

H 1 E7/01-A48 E5/01-A48 F7/01-A48

J 4 C5/01-A48 C5/01-A48 SIM C5/01-A48

K 1 F1/01-A44 RE: 01-A41 C7/01-A48

L 1 E7/01-A48 E5/01-A48 F7/01-A48

S1 3 E1/01-A48 D7 & C7/01-A42 F1/01-A48

S2 3 E1/01-A48 C1/01-A48 F1/01-A48

S2.1 3 E1/01-A48 C1/01-A48 F1/01-A48

S3 3 C1/01-A48 C1/01-A48 C1/01-A48

S4 3 C1/01-A48 C1/01-A48 C1/01-A48

S5 3 C1/01-A48 C1/01-A48 C1/01-A48

STOREFRONT/CURTAIN WALL FRAME SCHEDULE

FRAME TYPE DESCRIPTION

1 BOD: KAWNEER 1600 WALL SYSTEM 1, 7 1/"2 D x 2 1/2" W. ANODIZED

2 MATCH MANUFACTURER, PRODUCT LINE, AND FINISH OF PROJECT

NO 693-13-111 - REPLACE EXTERIOR WINDOWS.

3 BOD: KAWNEER TRIFAB 400, 4" D x 1 3/4" W. ANODIZED

4 BOD: MATCH EXISTING NORTH WINDOW FRAMES

9TH FLOOR

92' - 3 3/4"

9TH FLOOR

92' - 3 3/4"

BASEMENT

-14' - 0"

9TH FLOOR

92' - 3 3/4"

9TH FLOOR

92' - 3 3/4"

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A1 ADDENDUM 1 06/28/2024

A1

A1

BASEMENT

084413-A

088000-A

079200-C

079200-A

084113-B

079200-C

079200-A

092900-A

092216-A

042000-E

088000-A

A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT

ARE APPLICABLE.

B. EXTERIOR WINDOW PROFILES FOR SOUTH AND WEST ELEVATIONS ARE

REPRESENTATIVE OF INFORMATION FROM DRAWINGS PROVIDED TO

VALHALLA FROM VHA COR ON 02/10/2020 FROM VHA PROJECT #693-13-111.

WINDOW SIZES HAVE BEEN MODIFIED TO MATCH EXISTING OPENINGS AS

UNDERSTOOD BY VALHALLA AND ARE TO BE VERIFIED IN FIELD.

BASEMENT

-14' - 0"

079200-C

084413-A

088000-A

079200-A

084413-A

079200-A

092900-A

092216-A

079200-C

088000-A

Y

088000-A

084413-A

079200-C

079200-A

092900-A

092216-A

Y

088000-A

084413-A

079200-C

079200-A

092900-A

092216-A

9TH FLOOR

92' - 3 3/4"

084113-B

088000-A

088000-A

084113-B

PER RCP

092900-A

092216-A

PER RCP

EQ EQ

084113-B

088000-A

092216-A

092900-A

EQ EQ

9TH FLOOR

92' - 3 3/4"

U

079200-C

084413-A

088000-A

079200-A

075423-A

072200-B

072200-A

061000-D

077600-A

072200-D

092216-A

092900-A

079200-A

092216-A 076000-A

INFILL OPENING TO MATCH

EXISTING WALL

CONSTRUCTION ABOVE NEW

WINDOW AS NEEDED.

NEW WINDOW SYSTEM TO

MATCH EXISTING NORTH

WALL WINDOWS.

1' - 0"

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

######-AKEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:4

A M

01-A48

WINDOW DETAILS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 47 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

3" = 1'-0"

HEAD DETAIL - SOUTH WINDOWS

E3

3" = 1'-0"

SILL DETIAL - SOUTH WINDOWS

F3

042000-E AIR GAP

061000-D PLYWOOD SHEATHING

072200-A RIGID ROOF INSULATION

072200-B TAPERED ROOF INSULATION

072200-D GLASS MAT, WATER-RESISTANT GYPSUM ROOF BOARD

075423-A THERMOPLASTIC POLYOLEFIN (TPO) ROOFING SYSTEM

076000-A PREFINISHED SHEET METAL FLASHING

077600-A ROOFTOP TURF PAVER SYSTEM

079200-A JOINT SEALANT

079200-C BACKER ROD AND SEALANT

084113-B ALUMINUM-FRAMED STOREFRONT SYSTEM

084413-A GLAZED ALUMINUM CURTAIN WALL

088000-A GLAZING PER GLAZING SCHEDULE

092216-A METAL STUDS, RE WALL TYPE

092900-A GYPSUM BOARD

3" = 1'-0"

SILL DETAIL - WAREHOUSE STOREFRONT

F5

3" = 1'-0"

JAMB DETAIL - WAREHOUSE STOREFRONT

E5

3" = 1'-0"

SILL DETAIL - WAREHOUSE WINDOW

F7

3" = 1'-0"

HEAD DETAIL - WAREHOUSE WINDOW

E7

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A1 ADDENDUM 1 06/28/2024

3" = 1'-0"

SILL DETAIL - TYP INTERIOR STOREFRONT

F1

3" = 1'-0"

HEAD DETAIL - TYP INTERIOR STOREFRONT

E1

3" = 1'-0"

HEAD/SILL/JAMB DETAIL - INTERIOR STOREFRONT

C1

1 1/2" = 1'-0"

SILL DETAIL - SUNROOM CURTAIN WALL

C71 1/2" = 1'-0"

HEAD AND SILL DEATIL - WINDOW TYPE J

C5

G N

A

LI

G N

2" 2" 6" 6" 2" 6" 6" 2" 2"

HR-1, TYP

FEC

CG-1

8'

T Y

P

WALL BASE

CROSS CORRIDOR

DOOR LEAF

VERTICAL EXPANSION

JOINT COVER

T Y

P

1'

CROSS CORRIDOR

DOOR OPENING

4' - 6" TYP

1'

T

Y P

RWC-2

RWC-2

PNT-1/RWC-1

PNT-1/RWC-1

CG-1 CG-2

FINISH

FLOOR

(2 C

O U

R S

E S

P T

-2

(1 C

O U

R S

E

P T

-3

P N

T -S

C

PER RCP

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 7/

1/

0:

:4

A M

01-A49

FINISH SCHEDULE RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 49 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

FINISH SCHEDULE - 9TH FLOOR

ROOM

NUMBER

ROOM NAME

FLOORS WALLS

CEILING

WALL

PROTECTIONFLOOR BASE NORTH EAST SOUTH WEST

C9-00 COURTYARD PVR-1/TRF-1 - - - - - OPEN

C9-01 EAST SUNROOM WSF-1/WSF-2 RB-1 - - - EXIST PNT-C1

C9-02 HAC RES-6A RCB-1 PNT-SC1 PNT-SC1 PNT-SC1 PNT-SC1 ACT-SP RWC-1

C9-03 GROUP COUNSELING ROOM WSF-2 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 PNT-C1

C9-04 MEN'S WSF-2 WSF-2 PNT-2 PNT-2 PNT-2 PNT-3 PNT-C1

C9-04A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-05 TOILET PT-2 PT-2

PT-2/ PT-3/

PNT-SC1

PT-2/ PT-3/

PNT-SC1

PT-2/ PT-3/

PNT-SC1

PT-2/ PT-3/

PNT-SC1

PNT-C1

C9-06 MECHANICAL EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-06A ELEC EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-07 OFFICE WSF-2 RB-1 PNT-2 PNT-3 PNT-2 PNT-2 ACT-1

C9-08 MEN'S BARIATRIC WSF-2 WSF-2 PNT-2 PNT-2 PNT-2 PNT-3 PNT-C1

C9-08A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-09 ELEC EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-10 LAUNDRY RES-6A RCB-1 PNT-2 PNT-2 PNT-2 PNT-2 PNT-C1 RWC-1

C9-11 QUIET ROOM HSF-1 HSF-1 PNT-1 PNT-1 PNT-1 PNT-1 PNT-C1

C9-12 MEN'S WSF-2 WSF-2 PNT-2 PNT-3 PNT-2 PNT-2 PNT-C1

C9-12A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-13 SOILED UTILITY RES-6A RCB-1 PNT-SC1 PNT-SC1 PNT-SC1 PNT-SC1 ACT-SP RWC-1

C9-14 MEN'S WSF-2 WSF-2 PNT-2 PNT-2 PNT-2 PNT-3 PNT-C1

C9-14A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-15 MEN'S BARIATRIC WSF-2 WSF-2 PNT-2 PNT-2 PNT-2 PNT-3 PNT-C1

C9-15A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-16 DINING/ ACTIVITIES WSF-2 RB-1 PNT-1/ PNT-4 PNT-1/ PNT-4 PNT-1/ PNT-4 RWC-5 PNT-C1 RWC-2, CG-2

C9-17 GROUP THERAPY WSF-2 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 PNT-C1

C9-18 MEN'S WSF-2 WSF-2 PNT-2 PNT-3 PNT-2 PNT-2 PNT-C1

C9-18A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-19 ELEC EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-20 MEN'S WSF-2 WSF-2 PNT-2 PNT-2 PNT-2 PNT-3 PNT-C1

C9-20A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-21 SALLY PORT RES-6A RCB-1 PNT-1 PNT-1 PNT-1 PNT-1 PNT-C1 CG-1, RWC-1

C9-22 SERVING KITCHEN RES-6A RCB-1 PNT-2 PNT-2 PNT-2 PNT-2 ACT-1 RWC-1

C9-23 ELEVATOR LOBBY RES-6A RCB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1 CG-1, RWC-1

C9-24 MEN'S WSF-2 WSF-2 PNT-2 PNT-3 PNT-2 PNT-2 PNT-C1

C9-24A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-25 ANTE ROOM WSF-2 RB-1 PNT-2 PNT-2 PNT-2 PNT-2 PNT-C1

C9-25A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-25B SECLUSION ROOM HSF-1 HSF-1 RES-W1 RES-W1 RES-W1 RES-W1 PNT-C1

C9-26 LOBBY WSF-1/WSF-2 RB-1 PNT-5 PNT-5 PNT-5 PNT-5 PNT-C2/ PNT-C3 RWC-2, CG-2

C9-27 NURSE'S STATION WSF-1 RB-2 PNT-1 PNT-5 PNT-5 PNT-5 ACT-1 & PNT-C2

C9-27A NURSE'S WORKROOM WSF-1 RB-2 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1

C9-28 SALLY PORT WSF-2 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 PNT-C2 RWC-1

C9-29 INTERVIEW WSF-2 RB-1 PNT-2 PNT-2 PNT-2 PNT-1 PNT-C1

C9-30 ELEVATOR LOBBY WSF-1/WSF-2 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1 & PNT-C2 CG-1, RWC-1

C9-31 TELECOM ROOM N/A RB-1 PNT-2 PNT-2 PNT-2 PNT-2 OPEN

C9-32 MECHANICAL N/A RB-1 PNT-2 PNT-2 PNT-2 PNT-2 OPEN

C9-33 STAFF TOILET PT-2 PT-2

PT-2/ PT-3/

PNT-SC1

PT-2/ PT-3/

PNT-SC1

PT-2/ PT-3/

PNT-SC1

PT-2/ PT-3/

PNT-SC1

PNT-SC2

C9-34 ELEC EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-34A ELEC EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-35 NURSE'S LOUNGE LVT-1 RB-2 PNT-1 PNT-1 PNT-1 PNT-3 ACT-1 & PNT-C1

C9-35A LOCKERS LVT-1 RB-2 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1

C9-35B CLOSET LVT-1 RB-2 PNT-2 PNT-2 PNT-2 PNT-2 PNT-C1

C9-36 MECH EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-37 TEAMING/ COUNSELING WSF-2 RB-1 PNT-1 PNT-1 PNT-5 - PNT-C1

C9-38 EXAM/ INTAKE WSF-2 WSF-2 PNT-1 PNT-1 PNT-5 - PNT-C1

C9-39 HEAD NURSE OFFICE WSF-1 RB-2 PNT-3 PNT-2 PNT-2 PNT-2 ACT-1

C9-40 MED WSF-2 RB-1 PNT-2 PNT-2 PNT-2 PNT-2 ACT-1

C9-41 WOMEN'S WSF-2 WSF-2 PNT-2 PNT-3 PNT-2 PNT-2 PNT-C1

C9-41A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-42 STAFF TOILET PT-2 PT-2

PT-2/ PT-3/

PNT-SC1

PT-2/ PT-3/

PNT-SC1

PT-2/ PT-3/

PNT-SC1

PT-2/ PT-3/

PNT-SC1

PNT-SC2

C9-43 WOMEN'S WSF-2 WSF-2 PNT-2 PNT-2 PNT-2 PNT-3 PNT-C1

C9-43A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-44 WOMEN'S WSF-2 WSF-2 PNT-2 PNT-2 PNT-2 PNT-3 PNT-C1

C9-44A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-45 PATIENT STORAGE RES-6A RCB-1 PNT-2 PNT-2 PNT-2 PNT-2 PNT-C1

C9-46 LINEN RES-6A RCB-1 PNT-SC1 PNT-SC1 PNT-SC1 PNT-SC1 PNT-SC2

C9-47 OFFICE/ GROUP ROOM WSF-2 RB-1 PNT-2 PNT-2 PNT-2 PNT-2 PNT-C1

C9-47A STORAGE WSF-2 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 PNT-C1

C9-48 LAUNDRY RES-6A RCB-1 PNT-2 PNT-2 PNT-2 PNT-2 PNT-C1 RWC-1

C9-49 WOMEN'S BARIATRIC WSF-2 WSF-2 PNT-2 PNT-2 PNT-2 PNT-3 PNT-C1

C9-49A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-50 MEETING WSF-2 RB-1 PNT-2 PNT-2 PNT-2 PNT-2 PNT-C1

C9-51 HAC RES-6A RCB-1 PNT-SC1 PNT-SC1 PT-2/PNT-2 PNT-SC1 ACT-SP RWC-1

C9-52 SALLY PORT WSF-1 RB-2 PNT-1 PNT-1 PNT-1 PNT-1 PNT-C1 RWC-1

C9-53 ELEC EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-54 ELEVATOR LOBBY WSF-1/WSF-2 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1 & PNT-C2 CG-1, RWC-1

C9-55 MECHANICAL EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-56 CLEAN STORAGE RES-6A RCB-1 PNT-SC1 PNT-SC1 PNT-SC1 PNT-SC1 ACT-SP

C9-57 HAC RES-6A RCB-1 PNT-SC1 PNT-SC1 PNT-SC1 PNT-SC1 ACT-SP RWC-1

C9-58 ELECTRICAL EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-59

PREFUNCTION/

COLLABORATION

LVT-1 RB-2 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1 & PNT-C1

C9-60 CONFERENCE LVT-1 RB-2 PNT-1 PNT-1 PNT-1 PNT-4 ACT-1

C9-61 WORKSTATIONS LVT-1 RB-2 PNT-1 PNT-4 PNT-1 PNT-1 ACT-1

C9-62 ELEC EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-63 ELEC EXIST EXIST EXIST EXIST EXIST EXIST EXIST

C9-64 NURSE'S STATION WSF-1 RB-2 PNT-1 RWC-2 PNT-1 PNT-1 ACT-1 & PNT-C2

C9-65 MED WSF-1 RB-2 PNT-2 PNT-2 PNT-2 PNT-2 ACT-1

C9-66 GERIATRIC WSF-2 WSF-2 PNT-2 PNT-3 PNT-2 PNT-2 PNT-C1

C9-66A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-67 BARIATRIC GERIATRIC WSF-2 WSF-2 PNT-2 PNT-2 PNT-2 PNT-3 PNT-C1

C9-67A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-68 BARIATRIC GERIATRIC WSF-2 WSF-2 PNT-2 PNT-2 PNT-2 PNT-3 PNT-C1

C9-68A TOILET PT-1 PT-1 WP-1 WP-1 WP-1 WP-1 PNT-SC2

C9-69 OFFICE WSF-2 RB-1 PNT-2 PNT-3 PNT-2 PNT-2 PNT-C1

C9-70 CLEAN UTILITY RES-6A RCB-1 PNT-SC1 PNT-SC1 PNT-SC1 PNT-SC1 PNT-SC2

C9-71 GROUP THERAPY WSF-2 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 PNT-C1

C9-72 DAY/TV WSF-2 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 PNT-C1

FINISH SCHEDULE - WAREHOUSE

ROOM

NUMBER

ROOM NAME

FLOORS WALLS

CEILING

WALL

PROTECTIONFLOOR BASE NORTH EAST SOUTH WEST

L1-001 OXYGEN STORAGE EXIST EXIST EXIST EXIST EXIST EXIST EXIST

L1-100 STORAGE EXIST RB-3 PNT-2 PNT-2 PNT-2 PNT-2 OPEN

L1-100A ELEC EXIST RB-3 PNT-2 PNT-2 PNT-2 PNT-2 OPEN

L1-100E TELECOM ROOM EXIST RB-3 PNT-2 PNT-2 PNT-2 PNT-2 OPEN

L1-100F LOCKERS LVT-1 RB-3 PNT-2 PNT-2 PNT-2 PNT-2 PNT-C1

L1-100G TOILET PT-2 PT-2

PT-2/ PT-3/

PNT-SC1

PT-2/ PT-3/

PNT-SC1

PT…