05b - Drawings Architectural 3.pdf

PDF 32 MB Posted

Attached to
Y1DA--9th Floor MH Renovation WBVAMC
Solicitation number
36C24425B0018
Issued by

About this file

These architectural drawing files (01-A30 through 01-A53) detail the renovation plans for the 9th Floor Mental Health area at the Wilkes-Barre VA Medical Center, Project #693-19-106. The comprehensive set of drawings includes exterior elevations, interior layouts, wall sections, window and door schedules, finish schedules, and interior perspectives for a complete architectural renovation.

Key design elements include reconfiguring patient rooms, updating window systems with new glazing and integral blinds, installing new wall finishes (including rigid wall coverings and specialized paint), updating flooring with welded seam sheet flooring and luxury vinyl tiles, and redesigning nurse stations and common areas. The renovation focuses on creating a modern, functional mental health treatment environment with careful attention to materials, patient safety, and aesthetic considerations. The drawings are dated 04/18/2023 and prepared by Valhalla Engineering, with the project set to be a complete interior transformation of the 9th floor mental health wing.

View the file

Other files

File Type Posted
36C24425B0018 0001.docx DOCX document
19a - RFI Responses 2.pdf PDF
19b - RFI Responses 3.pdf PDF
16 - Wilkes Barre PA Campus Site Plan Crane Locations.pdf PDF
21 - WD PA20250095 M4 03-21-2025.pdf PDF
19 - RFI Responses.pdf PDF
18a - Safety Health During Construction Policy 18S-15-346.pdf PDF
20 - Brand Name JA 9F MHU 20241804.pdf PDF
18 - Safety VA Directive 7715 Rev 092023.pdf PDF
22 - 852.219-75 MUST SIGN AND RETURN WITH BID.pdf PDF
36C24425B0018_4.docx DOCX document
17 - Noise and Vibration Control.pdf PDF
12a - ICRA Introductory Information and Instructions.pdf PDF
36C24425B0018_3.docx DOCX document
15 - M P Cut Sheets 693 19 106.pdf PDF
12b - G-009 ICRA.pdf PDF
13 - Structural Calcs 693 19 106 .pdf PDF
14 - Estimate - 693 19 106 M P Calcs.pdf PDF
11 - Drawing Revisions.pdf PDF
12c - 17-H4 ICRA.pdf PDF
12e - 01-A4 ICRA.pdf PDF
12d - 01-A3 ICRA.pdf PDF
12 - ICRA Memo.pdf PDF
36C24425B0018_2.docx DOCX document
09 - Drawings Mechanical.pdf PDF
07 - Drawings General V2.pdf PDF
10 - Drawings Electrical.pdf PDF
06 - Drawings Fire Alarm and Protection.pdf PDF
10a - 17-E43 Revisions 2024-05-30.pdf PDF
08 - Drawings Plumbing.pdf PDF
03 - Drawings Hazardous Materials.pdf PDF
36C24425B0018 IFB Solicitation.pdf PDF
05a - Drawings Architectural 2.pdf PDF
01c - 107316 Aluminum Canopy System.pdf PDF
01d - 220523 Gen Duty Valves Plumb Piping.pdf PDF
36C24425B0018_1.docx DOCX document
02 - Drawings General V1.pdf PDF
05c - A15 Revisions 2024-05-30.pdf PDF
05 - Drawings Architectural 1.pdf PDF
04 - Drawings Structural.pdf PDF
01 - Specifications Project 693-19-106 .pdf PDF
01b - 087100 Door Hardware.pdf PDF
01a - 066116 Solid Surfacing Fabrication.pdf PDF
01e - 221100 Fac Water Distr.pdf PDF
36C24425B0018.docx DOCX document
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8TH FLOOR

80' - 11 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11TH FLOOR

115' - 4 3/4"

ABCDEFGHJKLMN

R E

B

-A

R E

B

-A

FOLDED ELEVATION

A R

E A

O F

W O

R K

R E

B

-A

22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"17' - 3"4' - 9"5' - 1"16' - 11"

1B 1B

8TH FLOOR

80' - 11 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11TH FLOOR

115' - 4 3/4"

A B C D E F G H J K L M N

R E

F

-A

R E

F

-A

A R

E A

O F

W O

R K

F4

01-A37

22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 17' - 3" 4' - 9" 5' - 1" 16' - 11"

1B.1 1B 1C 1C 1C 1C 1C 1C 1C 1C

8TH FLOOR

80' - 11 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11TH FLOOR

115' - 4 3/4"

9 10 11 12 13 14

A R

E A

O F

W O

R K

22' - 0" 23' - 0" 16' - 0" 10' - 0" 17' - 0"

1D.1

A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT

ARE APPLICABLE.

B. EXTERIOR WINDOW PROFILES FOR SOUTH AND WEST ELEVATIONS ARE

REPRESENTATIVE OF INFORMATION FROM DRAWINGS PROVIDED TO

VALHALLA FROM VHA COR ON 02/10/2020 FROM VHA PROJECT #693-13-111.

WINDOW SIZES HAVE BEEN MODIFIED TO MATCH EXISTING OPENINGS AS

UNDERSTOOD BY VALHALLA AND ARE TO BE VERIFIED IN FIELD.

C. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL

INFORMATION.

EXTERIOR ELEVATION LEGEND

NEW LINE TYPE

EXISTING LINE TYPE

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

0:

A M

01-A30

EXTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 30 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1/8" = 1'-0"

NORTH ELEVATION - WEST

B1

1/8" = 1'-0"

SOUTH ELEVATION - WEST

F1

1/8" = 1'-0"

WEST ELEVATION

D5

1 INSTALL NEW LAMINATED GLAZING AND SPANDREL PANELS IN EXISTING

WINDOW FRAME TO MATCH EXISTING LAYOUT. WINDOWS TO HAVE

INTEGRAL BLINDS BETWEEN LAYERS OF GLAZING.

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

ZMiller Image

8TH FLOOR

80' - 11 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11TH FLOOR

115' - 4 3/4"

1011121314

A R

E A

O F

W O

R K

B5

01-A36

D E F

8TH FLOOR

80' - 11 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11TH FLOOR

115' - 4 3/4"

NOPQRSTUV

R E

B

-A

R E

B

-A

3 1 1 1

A R

E A

O F

W O

R K

F1

01-A37

D5

01-A36

C B1 B A

F5

01-A36

8TH FLOOR

80' - 11 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11TH FLOOR

115' - 4 3/4"

M N O P Q R S T U V

R E

F

-A

A R

E A

O F

W O

R K

D5

01-A36

A B B1 C 1C 1C 1C 1C 1C 1C

F5

01-A36

A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT

ARE APPLICABLE.

B. EXTERIOR WINDOW PROFILES FOR SOUTH AND WEST ELEVATIONS ARE

REPRESENTATIVE OF INFORMATION FROM DRAWINGS PROVIDED TO

VALHALLA FROM VHA COR ON 02/10/2020 FROM VHA PROJECT #693-13-111.

WINDOW SIZES HAVE BEEN MODIFIED TO MATCH EXISTING OPENINGS AS

UNDERSTOOD BY VALHALLA AND ARE TO BE VERIFIED IN FIELD.

C. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL

INFORMATION.

EXTERIOR ELEVATION LEGEND

NEW LINE TYPE

EXISTING LINE TYPE

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

0:

A M

01-A31

EXTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 31 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1/8" = 1'-0"

EAST ELEVATION

D5

1/8" = 1'-0"

NORTH ELEVATION - EAST

B1

1/8" = 1'-0"

SOUTH ELEVATION - EAST

F1

1 NEW POLYCARBONATE GLAZING IN EXISTING WINDOW FRAME. WINDOWS

TO HAVE INTEGRAL BLINDS BETWEEN LAYERS OF GLAZING.

2 PREFINISHED ALUMINUM SUN SHADE; FINISH TO MATCH MULLIONS

3 NEW WINDOW SYSTEM, INFILL PARTIAL WALL TO NEW SILL HEIGHT

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

BASEMENT

-14' - 0"

H

BASEMENT

-14' - 0"

TUV

G

EXTERIOR ELEVATION LEGEND

NEW LINE TYPE

EXISTING LINE TYPE

A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

B. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL

INFORMATION.

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

17-A32

EXTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 32 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1/8" = 1'-0"

EAST WAREHOUSE ELEVATION

F5

1/8" = 1'-0"

NORTH WAREHOUSE ELEVATION

D5

1 STEEL STAIR, GUARD AND HANDRAIL

2 NEW AIR HANDLING UNIT; RE MECHANICAL

3 EXISTING AIR HANDLING UNIT

4 INSTALL WINDOW PANE IN DEMOLISHED EXHAUST FAN OPENING. MATCH

EXISTING WINDOW DESIGN AND GLAZING TYPE

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

OPEN TO

C9-27A

OPEN TO

C9-27

18 34 24

36 34 24

36 34 24

36 18 12

36 30 12

18 30 12

8' - 4 1/2"

F

F 900

34 25

34 25

A. REFER TO 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE APPLICABLE.

B. REFER TO 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING HEIGHTS OF

FIXTURES AND ACCESSORIES

C. REFER TO 01-A40 FOR MILLWORK DETAILS

D. REFER TO 01-A46 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND

FRAME DETAILS

E. REFER TO 01-A47 FOR WINDOW TYPES

F. REFER TO 01-A50 FOR FINISH SCHEDULE AND LEGEND.

36 34 24

12 34 24

36 18 12

12 30 12

2' - 3"

F

F900

34 25

32 25

34 25

34 25

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A33

INTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 33 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

3/8" = 1'-0"

C9-27 - SOUTH ELEVATION

C2

3/8" = 1'-0"

C9-68A - EAST ELEVATION

F7

3/8" = 1'-0"

C9-65 - WEST ELEVATION

E73/8" = 1'-0"

C9-64 - SOUTH ELEVATION

E5

3/8" = 1'-0"

C9-64 - EAST ELEVATION

F5

3/8" = 1'-0"

C9-33 - WEST ELEVATION

C7

3/8" = 1'-0"

C9-27A - NORTH ELEVATION

E2

3/8" = 1'-0"

C9-27 - NORTH ELEVATION

B2

3/8" = 1'-0"

C9-15A - EAST ELEVATION

B7

3/8" = 1'-0"

C9-15A - NORTH ELEVATION

C5

3/8" = 1'-0"

C9-15A - WEST ELEVATION

B5

3/8" = 1'-0"

C9-42 - SOUTH ELEVATION

F2

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

30 34 24

36 34 24

21 34 24

FF222

36 34 24

36 34 24

33 34 24

54 12

9' - 0"

F211

24 34 24 2"

F

A. REFER TO 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE APPLICABLE.

B. REFER TO 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING HEIGHTS OF

FIXTURES AND ACCESSORIES

C. REFER TO 01-A40 FOR MILLWORK DETAILS

D. REFER TO 01-A46 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND

FRAME DETAILS

E. REFER TO 01-A47 FOR WINDOW TYPES

F. REFER TO 01-A50 FOR FINISH SCHEDULE AND LEGEND.

36 34 24

18 34 24

18 34 24

36 34 24

36 30 12

36 30 12

36 30 12

36 30 12

3' - 0"

FF

F F

36 34 24

18 34 24

36 34 24

36 34 24

36 34 24

3' - 5 1/4" F211

21 34 24

36 34 24

36 34 24

30 34 24

30 30 12

27 30 12

36 18 12

36 30 12

21 30 12

3' - 3"

36 34 24

36 34 24

36 30 12

36 18 12

1 1/2"

F

36 34 24

36 34 24

24 34 24

8' - 0"

30 18

1 3/4"

1 3/4"

36 42 24

36 42 24

36 42 24

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A34

INTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 34 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

3/8" = 1'-0"

C9-22 - NORTH ELEVATION

F53/8" = 1'-0"

C9-22 - SOUTH ELEVATION

F43/8" = 1'-0"

C9-22 - WEST ELEVATION

F2

3/8" = 1'-0"

L1-104 - SOUTH ELEVATION

D73/8" = 1'-0"

L1-111 - EAST ELEVATION

D53/8" = 1'-0"

C9-28 - SOUTH ELEVATION

D2

3/8" = 1'-0"

C9-35A - EAST ELEVATION

C73/8" = 1'-0"

C9-35A - NORTH ELEVATION

C53/8" = 1'-0"

C9-35A - WEST ELEVATION

C43/8" = 1'-0"

C9-40 - EAST ELEVATION

C2

3/8" = 1'-0"

L1-104 - NORTH ELEVATION

B73/8" = 1'-0"

C9-38 - WEST ELEVATION

B53/8" = 1'-0"

C9-25 - SOUTH ELEVATION

B4

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

3/8" = 1'-0"

C9-35 - ISLAND ELEVATION

F7

RWC-2RWC-2

2' - 0"

RWC-4RWC-2

2' - 0"

RWC-2RWC-2

2' - 0"

RWC-2

RWC-2

1' - 8 7/8"

RWC-2RWC-3 RWC-2RWC-2

2' - 0"

RWC-4RWC-2

2' - 0"

RWC-2 RWC-3

RWC-3 RWC-2RWC-2

2' - 0"

RWC-4RWC-2

2' - 0"

RWC-2

RWC-2

1' - 8 7/8"RWC-2 RWC-3RWC-3

RWC-3 RWC-2RWC-2

2' - 0"

RWC-4RWC-2

2' - 0"

RWC-2 RWC-3RWC-2 RWC-3

RWC-3

RWC-2

2' - 0"

RWC-2 RWC-3

RWC-3 RWC-2RWC-2

2' - 0"

RWC-2

1' - 10 3/8" RWC-2 RWC-3RWC-2RWC-2

2' - 0"

RWC-4RWC-2

2' - 0"

RWC-2 RWC-3RWC-3

RWC-2RWC-3 RWC-2 RWC-3

A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

B. REFER TO 01-A50 FOR FINISH SCHEDULE AND LEGEND.

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A35

INTERIOR FINISH ELEVATIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 ZM AW

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 35 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

3/16" = 1'-0"

FINISH ELEVATION - CORRIDORS C9-C01 & C9-C03 - SOUTH

F1

3/16" = 1'-0"

FINISH ELEVATION - CORRIDORS C9-C01 & C9-C03 - NORTH

E1

3/16" = 1'-0"

FINISH ELEVATION - CORRIDOR C9-C06 - NORTH

C43/16" = 1'-0"

FINISH ELEVATION - CORRIDORS C9-C08 & C9-C09 - NORTH

C1

3/16" = 1'-0"

FINISH ELEVATION - CORRIDOR C9-C06 - SOUTH

D43/16" = 1'-0"

FINISH ELEVATION - CORRIDORS C9-C08 & C9-C09 - SOUTH

D1

3/16" = 1'-0"

FINISH ELEVATION - LOBBY C9-26 - SOUTH

B4

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

T U V

D5

01-A36

4' - 1 1/8"22' - 0"20' - 7 1/2"

F5

01-A36

01-A43

B6

01-A44

F1

01-A44

C1

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11121314 B5

01-A36

01-A44

F5

01-A43

D3

01-A44

F5

OPP

01-A43

D6

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION

REGARDING INTERIOR WALL CONSTRUCTION.

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

11121314 B5

01-A36

01-A44

C5

01-A43

F3

01-A43

F6

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A36

BUILDING SECTIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 36 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1/4" = 1'-0"

BUILDING SECTION 1 @ EAST SUNROOM

B5

1/4" = 1'-0"

BUILDING SECTION 2 @ COURTYARD

D5

1/4" = 1'-0"

BUILDING SECTION 2 @ EAST SUNROOM

F5

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

BASEMENT

-14' - 0"

01-A43

D1

01-A48

F5

SIM

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

01-A43

F1

01-A48

F3

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION

REGARDING INTERIOR WALL CONSTRUCTION.

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

9TH FLOOR

92' - 3 3/4"

10TH FLOOR

103' - 8 1/4"

01-A48

E3

01-A48

F3

SIM

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A37

WALL SECTIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 37 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

3/4" = 1'-0"

SECTION AT NEW WAREHOUSE STOREFRONT ENTRY

F63/4" = 1'-0"

SECTION AT DAY/TV - SOUTH WALL

F4

1 NEW WINDOW SYSTEM. WINDOWS TO HAVE INTEGRAL BLINDS BETWEEN

LAYERS OF GLAZING AND INTERIOR LAYER SHALL BE LAMINATED GLASS

2 EXISTING EXTERIOR MASONRY WALL

3 SCHEDULED CEILING, RE: REFLECTED CEILING PLAN

4 SCHEDULED FINISH FLOOR AND WALL BASE, RE: FINISH PLANS

5 EXISTING CONCRETE FLOOR STRUCTURE

6 NEW STOREFRONT SYSTEM AND DOOR TO ALIGN WITH EXISTING WINDOWS

AND MULLIONS

7 STEEL GUARD

3/4" = 1'-0"

SECTION AT MEN'S PATIENT ROOM C9-13 - NORTH WALL

F1 3/4" = 1'-0"

SECTION AT PATIENT TOILET ROOM C9-23A - SOUTH WALL

F3

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A

LI

G N

A

LI

G N

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO SHEET 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING

HEIGHTS OF FIXTURES AND ACCESSORIES.

D. ALIGN NEW WALLS WITH ADJACENT EXISTING WALLS WHERE NEW WALL

EXTENDS IN THE SAME DIRECTION.

E. ALIGN CENTER OF DEMISING WALLS OR FINISH FACE OF CHASE WALLS

WITH CENTER OF WINDOW MULLION, UNLESS NOTED OTHERWISE.

F. PARTITIONS TO BE TYPE S3A, UNLESS NOTED OTHERWISE. FURRING

ALONG EXTERIOR WALLS TO BE S2B.1, UNLESS NOTED OTHERWISE.

G. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL

INFORMATION.

C

C9-68A

TOILET

C9-66A

TOILET

6' - 7 3/8" 1' - 5" 11 1/8"

4'

/8

3'

4'

/8

01-A33 F7

9 5/8"

S3B.1

S3B.1

S3B.1

S3B.1 S3B.1

S3B.1

1'

/4

3'

S3B.1

S3B.1

S3B.1

S3B.1

C

C9-67A

TOILET

6' - 3 5/8" 9 3/4"

5' - 0" 1' - 4 1/2"

4'

1/ 4"

3'

3'

0"

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

8"

5'

S3B.1 S3B.1

S3B.1

S3B.1

S3B.1

F

C9-49A

TOILET

7' - 10 1/8" 4' - 0"

S8A.A

S3B.1

3'

5'

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

G

C9-43A

TOILET

C9-42

STAFF TOILET

S3B.1

S3B.1

S3B.1

S6A

S6A

6' - 8 1/8"

4'

/8

6'

/2

3'

"1' - 0 1/8"

01-A33

F2

4' - 0"

C9-44A

TOILET

C9-41A

TOILET

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

3'

1/ 2"

3'

4'

/8

3'

9 3/4"

3' - 0"

3' - 0"

11" 9 3/4"

S3B.1

L M

F3

01-A37

C9-24A

TOILET

C9-25A

TOILET

S3B.1

S3B.1

S6A.A21

S3B.1

S3B.1

3'

7/ 8"

3'

/8

4'

/8

2'

7 1/2"

5' - 2 7/8" 1' - 5" 6 3/8"

1' - 0 1/8"

3' - 2 7/8"

S3B.1

S3B.1

S3B.1

S3B.2

S6A

S3A.A21

O

C9-20A

TOILET

C9-18A

TOILET

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1 S3B.1

S3B.1

S3B.1

S3B.1

S3B.1 S3B.1

S3B.1 F1B

S3B.1

3' - 0"

9 3/4" 4' - 7" 1' - 9 3/8" S3B.1

F1B

9 3/4"

3'

/2

3'

4'

/4

3'

3' - 0"

Q

C9-15A

TOILET

5'

/4

3'

1' - 0 1/8" 4' - 3 1/4"

S3B.1

S3B.1

S3B.1

S3B.1

01-A33

C5

B7B5

01-A41

B5

Q

C9-12A

TOILET

C9-14A

TOILET

S3B.1

S3B.1

S3B.1

S3B.1S3B.1

S3B.1

S3B.1

S3B.1

S3B.1 S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

3'

1/ 4"

3'

4'

/8

3'

/4

1' - 5"

3' - 0"

3' - 0"

S6A

S6A

S

C9-07

OFFICE

C9-05

TOILET

C9-08A

TOILET

C9-06

4'

6'

/8

S3B.1

S3B.1S3B.1

5' - 0" 1' - 4 1/2" 8' - 4 1/4"

6' - 9 1/4" 1' - 8 1/2"

2'

7'

/2

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1 S3B.1

S3B.1

S3B.1

S6A

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A38

ENLARGED FLOOR PLANS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 38 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-66A AND C9-68A

F7

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-67A

B7

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-49A

D7

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-42 AND C9-43A

F5

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-41A AND C9-44A

D5

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-24A AND C9-25A

F33/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-18A AND C9-20A

F1

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-15A

D33/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-12A AND C9-14A

D1

3/8" = 1'-0"

ENLARGED RESTROOM PLAN - C9-05 AND C9-08A

B3

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

DN

ALIGN

O

C9-22

SERVING KITCHEN

01-A34

F4

F2

F5

S3B.1

2' - 1"

S3B.1

S3B.1

S3B.1

4'

/8

L M

C9-35A

LOCKERS

S3B.1

1'

5'

/8

3'

3'

1"

2' - 4 3/4"

1' - 11 3/8" 7' - 8" 1' - 6 5/8" 2' - 4 1/4"

120°

S3B.1 S3B.1S3B.1F1BS3B.1

S3B.1

1' - 6"

S3B.1

01-A34

C5

C7C4

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO SHEET 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING

HEIGHTS OF FIXTURES AND ACCESSORIES.

D. ALIGN NEW WALLS WITH ADJACENT EXISTING WALLS WHERE NEW WALL

EXTENDS IN THE SAME DIRECTION.

E. ALIGN CENTER OF DEMISING WALLS OR FINISH FACE OF CHASE WALLS

WITH CENTER OF WINDOW MULLION, UNLESS NOTED OTHERWISE.

F. PARTITIONS TO BE TYPE S3A, UNLESS NOTED OTHERWISE. FURRING

ALONG EXTERIOR WALLS TO BE S2B.1, UNLESS NOTED OTHERWISE.

G. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL

INFORMATION.

T

C9-02

HAC

C9-04A

TOILET

S2B.1

S3B.1

1' - 4 7/8" 3' - 7 1/4" 3' - 6 3/8"

6'

/4

4'

/8

S6A

S3B.1

S3B.1

S3B.1

S3B.1

F6

01-A37

G

J

7' - 1 3/4" 4' - 0" F1

01-A40

D

01-A33 F5

F1

01-A40

2'

S4

R

' - 1

3'

2' - 8 3/8"

5' - 5 13/16"

2' - 6"

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A39

ENLARGED FLOOR PLANS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 39 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1 INFILL EXISTING WINDOW OPENING WITH WALL TO MATCH ADJACENT

3/8" = 1'-0"

ENLARGED FLOOR PLAN - C9-22

F4 3/8" = 1'-0"

ENLARGED FLOOR PLAN - C9-35A

F7

3/8" = 1'-0"

ENLARGED FLOOR PLAN - C9-02 AND C9-03

D7

3/8" = 1'-0"

ENLARGED WAREHOUSE STAIR PLAN

F2

3/8" = 1'-0"

ENLARGED PLAN - C9-27 DESK

D4

3/8" = 1'-0"

ENLARGED PLAN - C9-64 DESK

B4

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

2"

60°

1' - 0"

7'

123200-A

123200-E

2"

4"

096513-A

123200-E

123200-A

061000-D

123600-A

123600-B

123200-G

061000-C

123600-A

061000-D

123600-C

096513-A

061000-C

2'

0"

2' - 1"

A. REFER TO FINISH LEGEND AND FINISH SCHEDULE FOR SPECIFIC FINISH

INFORMATION.

B. ALL MILLWORK/ CASEWORK CONSTRUCTION SHALL MEET AWI PREMIUM

STANDARDS, UNLESS NOTED OR SPECIFIED OTHERWISE.

C. ALL EXPOSED MILLWORK/ CASEWORK SURFACES SHALL BE FINISHED W/

PLASTIC LAMINATE TO MATCH ADJACENT PLASTIC LAMINATE SURFACES,

UNLESS NOTED OTHERWISE.

D. ALL CASEWORK INTERIORS SHALL BE WHITE MELAMINE, UNLESS NOTED

OTHERWISE.

E. ALL FILLER PANELS SHALL BE 1-1/2 INCH WIDE MINIMUM, FINISHED TO

MATCH ADJACENT FINISH SURFACES, AND SCRIBED TO FIT ADJACENT

WALL, UNLESS NOTED OTHERWISE.

F. ALL BACKSPLASH FINISHES SHALL MATCH COUNTERTOP MATERIAL AND

FINISH, UNLESS NOTED OTHERWISE. PLASTIC LAMINATE

SIDE/BACKSPLASHES TO HAVE SELF EDGE LAMINATE, UNLESS NOTED

OTHERWISE.

G. CONTRACTOR SHALL APPLY CLEAR MILDEW RESISTANT SILICONE SEALANT

WHERE BACKSPLASH MEETS WALL AND COUNTERTOP.

H. THE UNDERSIDE OF COUNTERTOPS WITH KNEE OPENINGS, MUST HAVE A

WHITE MELAMINE FINISH, UNLESS NOTED OTHERWISE.

I. WATER AND SUPPLY DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL

BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST

CONTACT. THERE SHALL BE NO SHARP OF ABRASIVE SURFACES UNDER

LAVATORIES AND SINKS.

4"

096513-A

123200-A

061000-D

123600-A

123600-B

123200-G

061000-C

224000-D

1'

1' - 6"

3"

123200-A

061000-C

9TH FLOOR

92' - 3 3/4"

1'

092216-A

088000-B

123600-C

096513-A

061000-D

123200-A

092216-A092900-A

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A40

MILLWORK SECTIONS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 40 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L1 1/2" = 1'-0"

CASEWORK SECTION - CDS 301 & 302

F3 1 1/2" = 1'-0"

CASEWORK SECTION - CDS 211 & 222

F71 1/2" = 1'-0"

CASEWORK SECTION - CDS 900

F5

061000-C WOOD BLOCKING

061000-D PLYWOOD SHEATHING

088000-B SECURITY GLAZING

092216-A METAL STUDS, RE WALL TYPE

092900-A GYPSUM BOARD

096513-A RESILIENT BASE, RE FINISH SCHEDULE

123200-A PLASTIC LAMINATE CASEWORK

123200-E ADJUSTABLE SHELF

123200-G WIRE PULL

123600-A PLASTIC LAMINATE COUNTERTOP

123600-B PLASTIC LAMINATE BACKSPLASH

123600-C COUNTER BRACKET

224000-D HAND SINK, RE PLUMBING

1 1/2" = 1'-0"

CASEWORK SECTION - CDS 152

D7

1 1/2" = 1'-0"

CORRIDOR BENCH DETAIL

B7

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

1 1/2" = 1'-0"

CASEWORK SECTION - NURSE STATION

F1

ALIGN

1' - 5"

2'

0"

074000-C

079200-A

084113-B

079200-C

072113-B

092216-A

061000-B

088000-A

/4

072727-A

U

1' - 5" 1' - 5"

3'

4'

/4

EQ 1" EQ

074000-C

079200-A

084113-B

079200-C

061000-C

072113-B

061000-B

092216-A

088000-A

2'

1"

072727-A

V

2' - 10"

4'

/4

EQ 1" EQ

074000-C

084113-B

061000-C

092216-A

061000-B

079200-C

079200-A

088000-A

2'

1"

072727-A

V

3'

/4

1' - 6" 1' - 4"

E Q

1" E

Q

079200-A

084113-B

074000-C

061000-B

061000-C

079200-C

088000-A

072727-A

RE FLOOR PLAN

EQ EQ

092900-D

092216-A

092900-A

084113-B

3/

8"

088000-A

RE FLOOR PLAN

S8A.A

S8A.A

S8A.A

EQ EQ

084113-B

092900-A

092216-A

088000-A

1'

RE FLOOR PLAN

EQ EQ

S3A

S3A S3A

X

10 1/2"

2'

/8

S 3B

.1

S3B.1

S 3B

.1

S3B.1

4' - 6"

6"95°

4"

084113-B

079200-C

074000-C

061000-B

079200-A

092216-A

1' - 5"

088000-A

072727-A

14S3B.1

092900-D

EQ EQ088000-A

084113-B

092900-A

092216-A

A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

B. REFER TO FLOOR PLANS AND ENLARGED PLANS FOR ADDITIONAL

PARTITION TYPES.

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

######-AKEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A41

PLAN DETAILS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 41 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1 1/2" = 1'-0"

COLUMN DETAIL

F1 1 1/2" = 1'-0"

COLUMN U-14 DETAIL

F4 1 1/2" = 1'-0"

COLUMN V-14 DETAIL

F7

1 1/2" = 1'-0"

COLUMN V-13 DETAIL

D71 1/2" = 1'-0"

PLAN DETAIL - PARTITION TO NEW WINDOW

D3

1 1/2" = 1'-0"

PLAN DETIAL - DEMISING WALL TO WINDOW

B7

1 1/2" = 1'-0"

PLAN DETAIL - PARTITION TO EXISTING WINDOW

D1 1 1/2" = 1'-0"

PLAN DETAIL - L1-104

D5

1 1/2" = 1'-0"

PLAN DETAIL - TYPICAL PATIENT ROOM DOOR

B2

1 1/2" = 1'-0"

COLUMN U/V-14 DETAIL

F5

061000-B FIRE-RETARDANT-TREATED PLYWOOD SHEATHING

061000-C WOOD BLOCKING

072113-B EXTRUDED-POLYSTYRENE BOARD INSULATION WITH TAPED AND

SEALED SEAMS

072727-A FLUID-APPLIED MEMBRANE AIR BARRIER, VAPOR RETARDING

074000-C METAL WALL PANELS

079200-A JOINT SEALANT

079200-C BACKER ROD AND SEALANT

084113-B ALUMINUM-FRAMED STOREFRONT SYSTEM

088000-A GLAZING PER GLAZING SCHEDULE

092216-A METAL STUDS, RE WALL TYPE

092900-A GYPSUM BOARD

092900-D METAL TRIM

1 1/2" = 1'-0"

PLAN DETAIL - QUIET ROOM WINDOW

B5

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

1' - 0"

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

S3B.1

1'

/8

084113-B

9 3/4"

1'

/4

1/

2"

S3B.1

S3B.1

S3B.1

084113-B

5"

102600-K

092216-A

092900-A

A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

B. REFER TO FLOOR PLANS AND ENLARGED PLANS FOR ADDITIONAL

PARTITION TYPES.

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

######-AKEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A42

PLAN DETAILS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 42 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1 1/2" = 1'-0"

PLAN DETAIL - DOOR C9-08

F7

1 1/2" = 1'-0"

PLAN DETAIL - DOOR C9-16

D7

1 1/2" = 1'-0"

PLAN DETAIL - DOOR C9-16A

C7

1 1/2" = 1'-0"

PLAN DETAIL - TYP CORRIDOR DOOR

B7

084113-B ALUMINUM-FRAMED STOREFRONT SYSTEM

092216-A METAL STUDS, RE WALL TYPE

092900-A GYPSUM BOARD

102600-K END GUARD, RE FINISH LEGEND

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

9TH FLOOR

92' - 3 3/4"

072200-B

077600-A

092900-B

092216-B

076000-A

079200-A 088000-A

084113-B

079200-C

061000-C

079200-A

6"

PER RCP

079200-C

084113-B

088000-A

079200-A

092900-A

092216-A

095100-A

6"

PER RCP

E Q

E Q

084113-B

079200-C 079200-A

092216-A

092900-A

088000-A

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION

REGARDING INTERIOR WALL CONSTRUCTION.

9TH FLOOR

92' - 3 3/4"

061000-B

096513-A

092900-A

072113-B

076000-A

079200-A088000-A

084113-B

079200-C

061000-C

9TH FLOOR

92' - 3 3/4"

2"

061000-B

096513-A

092900-A

072113-B

092216-A

079200-A 088000-A

084113-B

079200-C

061000-C

076000-A

051200-E

9TH FLOOR

92' - 3 3/4"

072200-B

079200-A

092216-B

092900-A

076000-A

079200-A

088000-A

084113-B

079200-C

061000-C

076000-A 033000-G

9TH FLOOR

92' - 3 3/4"

V

072200-B

079200-A

092216-B

092900-B

076000-A

079200-A

088000-A

084113-B

079200-C

061000-C

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

00KEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A43

SECTION DETAILS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 43 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1 1/2" = 1'-0"

DETAIL @ COURTYARD SOUTH STOREFRONT SILL

D31 1/2" = 1'-0"

CEILING DETAIL AT WAREHOUSE STOREFRONT

D1

1 1/2" = 1'-0"

SECTION DETAIL - CEILING TO MULLION

F1

033000-G CONCRETE WALL

051200-E STEEL PLATE, RE STRUCTURAL

061000-B FIRE-RETARDANT-TREATED PLYWOOD SHEATHING

061000-C WOOD BLOCKING

072113-B EXTRUDED-POLYSTYRENE BOARD INSULATION WITH TAPED AND

SEALED SEAMS

072200-B TAPERED ROOF INSULATION

076000-A PREFINISHED SHEET METAL FLASHING

077600-A ROOFTOP TURF PAVER SYSTEM

079200-A JOINT SEALANT

079200-C BACKER ROD AND SEALANT

084113-B ALUMINUM-FRAMED STOREFRONT SYSTEM

088000-A GLAZING PER GLAZING SCHEDULE

092216-A METAL STUDS, RE WALL TYPE

092216-B METAL HAT CHANNEL, RE WALL TYPE

092900-A GYPSUM BOARD

092900-B GLASS MAT GYPSUM BOARD

095100-A ACOUSTICAL PANEL CEILING, RE FINISH SCHEDULE

096513-A RESILIENT BASE, RE FINISH SCHEDULE

1 1/2" = 1'-0"

DETAIL @ SUNROOM SOUTH STOREFRONT SILL

F3 1 1/2" = 1'-0"

DETAIL @ SUNROOM NORTH STOREFRONT SILL

F6

1 1/2" = 1'-0"

DETAIL @ COURTYARD NORTH STOREFRONT SILL

D6

1 1/2" = 1'-0"

DETAIL @ COURTYARD EAST SUNROOM SILL

B6

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR MORE INFORMATION.

B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE

APPLICABLE.

C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION

REGARDING INTERIOR WALL CONSTRUCTION.

10TH FLOOR

103' - 8 1/4"

1'

1/ 2"

1/

2" 1'

/2

3' - 10 7/8" 1' - 10 3/4"

6"

6"

6"

6"

6"

074000-C

072200-D072200-B

074000-D

061000-B

092216-A

TYP

70°

074000-L 074000-H074000-H

072727-A

075423-A

6"

6"

6"

6"

074000-C

061000-B

092216-A

072113-B

072200-D

072200-B

074000-D

079200-C

061000-C

084113-B

088000-A

079200-A

092900-A

074000-L 074000-H

1'

1/ 2"

1'

3' - 10 7/8" 1' - 10 3/4"

075423-A

10TH FLOOR

103' - 8 1/4"

U

074000-D

074000-C

061000-B

092216-A

092900-A

072113-B

092216-A

084113-B

061000-C

079200-C

079200-A

072200-D

072200-B

088000-A

074000-H

5 3/8"

075423-A

10TH FLOOR

103' - 8 1/4"

V

6"

6"

6"

6"

6"

074000-C

061000-B

092216-A

079200-C

084113-B

088000-A 061000-C

079200-A

074000-H 074000-L

074000-D

072200-D

072200-B

1' - 4" 2' - 8 5/8"

1'

5/ 8"

1'

/8

075423-A

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

######-AKEYNOTES

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A44

SECTION DETAILS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 43 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

061000-B FIRE-RETARDANT-TREATED PLYWOOD SHEATHING

061000-C WOOD BLOCKING

072113-B EXTRUDED-POLYSTYRENE BOARD INSULATION WITH TAPED AND

SEALED SEAMS

072200-B TAPERED ROOF INSULATION

072200-D GLASS MAT, WATER-RESISTANT GYPSUM ROOF BOARD

072727-A FLUID-APPLIED MEMBRANE AIR BARRIER, VAPOR RETARDING

074000-C METAL WALL PANELS

074000-D PARAPET CAP BY WALL PANEL MANUFACTURER

074000-H METAL SOFFIT PANEL

074000-L PERFORATED METAL SOFFIT PANEL

075423-A THERMOPLASTIC POLYOLEFIN (TPO) ROOFING SYSTEM

079200-A JOINT SEALANT

079200-C BACKER ROD AND SEALANT

084113-B ALUMINUM-FRAMED STOREFRONT SYSTEM

088000-A GLAZING PER GLAZING SCHEDULE

092216-A METAL STUDS, RE WALL TYPE

092900-A GYPSUM BOARD

1 1/2" = 1'-0"

DETAIL @ COURTYARD ROOF EAVE (SOUTH)

F5

1 1/2" = 1'-0"

DETAIL @ EAST SUNROOM ROOF EAVE

C5

1 1/2" = 1'-0"

DETAIL @ EAST SUNROOM STOREFRONT HEAD

F1

1 1/2" = 1'-0"

DETAIL @ COURTYARD ROOF EAVE (EAST)

C1

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

5/8" GYPSUM WALL BOARD EACH SIDE (ABUSE

RESISTANT IN ALL PATIENT ROOMS)

CONTINUOUS SEALANT AT SOUND / SMOKE WALLS

CEILING AS INDICATED ON RCP

CONT FULL-HEIGHT SOUND BATT INSULATION TO

MEET STC RATING

CONT METAL RUNNERS TOP AND BOTTOM

SECTION VIEW

RE: SCHED

METAL STUDS WITH HORIZONTAL BRACING AS REQ'D

# SEE SCHEDULE

GYPSUM BOARD (09 29 00) ON BOTH SIDES OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO UNDERSIDE OF

FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.

PARTITION TYPE

S3A

S3A.A S6A

STUD SIZE

3-5/8" 3-5/8"

6"

STC RATING

N/A

N/A

FRR TEST

N/A

UL XXX

N/A

HEAD DETAIL

BASE DETAIL

S##.X

PARTITION WIDTH

4-7/8" 4-7/8" 7-1/4"

BOTTOM OF

FLOOR/ROOF CONST

FINISHED CEILING HEIGHT

FLOOR/ROOF CONST

FINISHED FLOOR

5/8" GYPSUM WALL BOARD EACH SIDE (ABUSE

RESISTANT IN ALL PATIENT ROOMS)

CONTINUOUS SEALANT AT SOUND / SMOKE WALLS

CEILING AS INDICATED ON RCP

CONT FULL-HEIGHT SOUND BATT INSULATION TO

MEET STC RATING

CONT 8" METAL RUNNERS TOP AND BOTTOM

SECTION VIEW

RE: SCHED

METAL STUDS WITH HORIZONTAL BRACING AS REQ'D

# SEE SCHEDULE

GYPSUM BOARD (09 29 00) ON BOTH SIDES OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO UNDERSIDE OF

FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.

PARTITION TYPE

S8A.A

STUD SIZE

(2) 3-5/8"

STC RATING

FRR TEST

N/A

HEAD DETAIL

BASE DETAIL

S8A.A

PARTITION WIDTH

9-1/4"

BOTTOM OF

FLOOR/ROOF CONST

FINISHED CEILING HEIGHT

FLOOR/ROOF CONST

FINISHED FLOOR

5/8" GYPSUM WALL BOARD ROOM SIDE (ABUSE

RESISTANT IN ALL PATIENT ROOMS)

CONTINUOUS SEALANT AT SOUND / SMOKE WALLS

CEILING AS INDICATED ON RCP

CONT FULL-HEIGHT SOUND BATT INSULATION TO

MEET STC RATING

CONT METAL RUNNERS TOP AND BOTTOM

SECTION VIEW

METAL STUDS WITH HORIZONTAL BRACING AS REQ'D

GYPSUM BOARD (09 29 00) ON ROOM SIDE OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO ABOVE CEILING.

PARTITION TYPE

S2B.1 S3B.1

STUD SIZE

2-1/2" 3-5/8"

STC RATING

N/A N/A

FRR TEST

N/A N/A

HEAD DETAIL

BASE DETAIL

S##.1

PARTITION WIDTH

3-1/8" 4-1/4"

1/2" AIR GAP FOR S2# WALL TYPES

6"

BOTTOM OF

FLOOR/ROOF CONST

FINISHED CEILING HEIGHT

FLOOR/ROOF CONST

FINISHED FLOOR

RE SCHED

5/8" GYPSUM WALL BOARD ROOM SIDE (ABUSE

RESISTANT IN ALL PATIENT ROOMS)

CEILING AS INDICATED ON RCP

CONT METAL RUNNERS TOP AND BOTTOM

SECTION VIEW

METAL FURRING

# SEE SCHEDULE

GYPSUM BOARD (09 29 00) ON ROOM SIDE OF NON-STRUCTURAL METAL FURRING (09 22 16) TO UNDERSIDE OF

FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.

PARTITION TYPE

F0B F1B

STUD SIZE

7/8"

1-1/2"

STC RATING

N/A N/A

FRR TEST

N/A N/A

HEAD DETAIL

BASE DETAIL

F##.X

PARTITION WIDTH

1-1/2" 2-1/8"

EXISTING CONSTRUCTION

BOTTOM OF

FLOOR/ROOF CONST

FINISHED CEILING HEIGHT

FLOOR/ROOF CONST

FINISHED FLOOR

RE SCHED

5/8" GYPSUM WALL BOARD EACH SIDE (ABUSE

RESISTANT IN ALL PATIENT ROOMS)

CONTINUOUS SEALANT AT SOUND / SMOKE WALLS

CEILING AS INDICATED ON RCP

CONT FULL-HEIGHT SOUND BATT INSULATION TO

MEET STC RATING

CONT 8" METAL RUNNERS TOP AND BOTTOM

SECTION VIEW

RE: SCHED

METAL STUDS WITH HORIZONTAL BRACING AS REQ'D

# SEE SCHEDULE

GYPSUM BOARD (09 29 00) ON BOTH SIDES OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO UNDERSIDE OF

FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.

PARTITION TYPE

S8A.A21

STUD SIZE

(2) 3-5/8"

STC RATING

FRR TEST

N/A

HEAD DETAIL

BASE DETAIL

S##.X

PARTITION WIDTH

9-7/8"

SECLUSION ROOM

BOTTOM OF

FLOOR/ROOF CONST

FINISHED CEILING HEIGHT

FLOOR/ROOF CONST

FINISHED FLOOR

5/8" GYPSUM WALL BOARD EACH SIDE (ABUSE

RESISTANT IN ALL PATIENT ROOMS)

CONTINUOUS SEALANT AT SOUND / SMOKE WALLS

CEILING AS INDICATED ON RCP

CONT FULL-HEIGHT SOUND BATT INSULATION TO

MEET STC RATING

CONT METAL RUNNERS TOP AND BOTTOM

SECTION VIEW

RE: SCHED

METAL STUDS WITH HORIZONTAL BRACING AS REQ'D

# SEE SCHEDULE

GYPSUM BOARD (09 29 00) ON BOTH SIDES OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO UNDERSIDE

OF FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.

PARTITION TYPE

S3A.21

S3A.A21 S6A.A21

STUD SIZE

3-5/8" 3-5/8"

6"

STC RATING

N/A

FRR TEST

N/A N/A N/A

HEAD DETAIL

BASE DETAIL

S##.X21

PARTITION WIDTH

5-1/2" 5-1/2" 7-7/8"

SECLUSION ROOM

BOTTOM OF

FLOOR/ROOF CONST

FINISHED CEILING HEIGHT

FLOOR/ROOF CONST

FINISHED FLOOR

(2) LAYERS 5/8" GYPSUM WALL BOARD ROOM SIDE

(ABUSE RESISTANT IN ALL PATIENT ROOMS)

CONTINUOUS SEALANT AT SOUND / SMOKE WALLS

CEILING AS INDICATED ON RCP

CONT FULL-HEIGHT SOUND BATT INSULATION TO

MEET STC RATING

CONT METAL RUNNERS TOP AND BOTTOM

SECTION VIEW

METAL STUDS WITH HORIZONTAL BRACING AS REQ'D

2 LAYERS GYPSUM BOARD (09 29 00) ON ROOM SIDE OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO ABOVE

CEILING.

PARTITION TYPE

S2B.2

S3B.A2

STUD SIZE

2-1/2" 3-5/8"

STC RATING

N/A

FRR TEST

N/A N/A

HEAD DETAIL

BASE DETAIL

S##.2

PARTITION WIDTH

3-3/4" 4-7/8"

1/2" AIR GAP FOR H2# WALL TYPES

6"

SECLUSION ROOM

BOTTOM OF

FLOOR/ROOF CONST

FINISHED CEILING HEIGHT

FLOOR/ROOF CONST

FINISHED FLOOR

RE SCHED

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A45

WALL TYPE SCHEDULE RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 44 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

F SRG1

P E

R S

C H

E D

U

LE

CV

SCHED

PER

1'

SRG2A

1'

6" TYP

P E

R S

C H

E D

U

LE

SCHED

PER PER SCHEDULE

2'

0"

S C

H E

D U

LE

P E

R

P E

R S

C H

E D

U

LE

SCHED

PER

6"

F1 F2

P E

R S

C H

E D

U

LE

2"

2"

SIDELITE

2' - 0" 2" 2"

P E

R S

C H

E D

U

LE

2"

2"

F3

DOUBLE EGRESS

PER SCH2"

SCHED

PER 2"

P E

R S

C H

E D

U

LE

2"

2" PER SCHEDULE 2"

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A46

DOOR SCHEDULES & DETAILS RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 45 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

1/4" = 1'-0"

DOOR PANEL TYPE LEGEND

1/4" = 1'-0"

DOOR FRAME TYPE LEGEND

DOOR SCHEDULE - 9TH FLOOR

NUMBER ROOM NAME

DOOR FRAME

RATING

DETAIL

COMMENTS

SIZE

TYPE

LEAF

NUMBER

LEAF 1

SIZE

LEAF 2

SIZE MATERIAL FINISH TYPE MATERIAL FINISH DOOR HEAD DOOR JAMB

C9-00 COURTYARD 84" x 84" SRG2A 2 3' - 6" 3' - 6" ALUM/GL ANOD ALUM ANOD -

C9-01 EAST SUNROOM 72" x 84" SRG2A 2 3' - 0" 3' - 0" ALUM/GL ANOD F1 HM PNT -

C9-02 HAC 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-03 GROUP COUNSELING ROOM 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-04 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-04A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-05 TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-06 MECHANICAL 42" x 84" F 1 3' - 6" WD STN F1 HM PNT 45 MIN

C9-06A ELEC 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-07 OFFICE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-08 MEN'S BARIATRIC 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -

C9-08A TOILET 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -

C9-10 LAUNDRY 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-11 QUIET ROOM 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-11A QUIET ROOM 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-12 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-12A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-14 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-14A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-15 MEN'S BARIATRIC 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -

C9-15A TOILET 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -

C9-16 DINING/ ACTIVITIES 42" x 84" SRG2A 1 3' - 6" ALUM/GL ANOD ALUM ANOD -

C9-16A DINING/ ACTIVITIES 42" x 84" SRG2A 1 3' - 6" ALUM/GL ANOD ALUM ANOD -

C9-16B DINING/ ACTIVITIES 36" x 48" CV 1 3' - 0" MTL PNT MTL PNT -

C9-17 GROUP THERAPY 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-18 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-18A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-20 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-20A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-21 SALLY PORT 72" x 84" F 2 3' - 0" 3' - 0" WD STN F1 HM STN -

C9-22 SERVING KITCHEN 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-23 ELEVATOR LOBBY 72" x 84" F 2 3' - 0" 3' - 0" WD STN F1 HM STN -

C9-24 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-24A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-25 ANTE ROOM 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-25A TOILET 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-25B SECLUSION ROOM 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-27 NURSE'S STATION 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-28 SALLY PORT 42" x 84" SRG2A 1 3' - 6" ALUM/GL STN F1 HM PNT -

C9-29 INTERVIEW 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-30 ELEVATOR LOBBY 42" x 84" SRG2A 1 3' - 6" ALUM/GL STN F1 HM PNT -

C9-31 TELECOM ROOM 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-32 MECHANICAL 36" x 84" F 1 3' - 0" WD STN F1 HM PNT 90 MIN

C9-33 STAFF TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-35 NURSE'S LOUNGE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-35B CLOSET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-36 MECH 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-37 TEAMING/ COUNSELING 42" x 84" SRG2A 1 3' - 6" ALUM/GL ANOD ALUM ANOD -

C9-38 EXAM/ INTAKE 42" x 84" SRG2A 1 3' - 6" ALUM/GL ANOD ALUM ANOD -

C9-39 HEAD NURSE OFFICE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-40 MED 36" x 84" F 1 3' - 0" WD STN F1 HM PNT 45 MIN

C9-41 WOMEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-41A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-42 STAFF TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-43 WOMEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-43A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-44 WOMEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-44A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-45 PATIENT STORAGE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-46 LINEN 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-47 OFFICE/ GROUP ROOM 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-47A STORAGE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-49 WOMEN'S BARIATRIC 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -

C9-49A TOILET 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-50 MEETING 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-51 HAC 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-52 SALLY PORT 42" x 84" SRG2A 1 3' - 6" ALUM/GL STN F1 HM PNT -

C9-54 ELEVATOR LOBBY 42" x 84" SRG2A 1 3' - 6" ALUM/GL STN F1 HM PNT -

C9-55 MECHANICAL 36" x 84" F 1 3' - 0" WD STN F1 HM PNT 45 MIN

C9-56 CLEAN STORAGE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT 45 MIN

C9-57 HAC 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-59 PREFUNCTION/ COLLABORATION 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-60 CONFERENCE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-64 NURSE'S STATION 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-65 MED 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-66 GERIATRIC 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-66A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-67 BARIATRIC GERIATRIC 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -

C9-67A TOILET 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -

C9-68 BARIATRIC GERIATRIC 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -

C9-68A TOILET 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-69 OFFICE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-70 CLEAN UTILITY 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-71 GROUP THERAPY 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-72 DAY/TV 72" x 84" SRG2A 2 3' - 0" 3' - 0" ALUM/GL STN F1 HM PNT -

C9-C01 CORRIDOR 90" x 84" SRG2A 2 3' - 9" 3' - 9" ALUM/GL ANOD F3 HM PNT -

C9-C02 CORRIDOR 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

C9-C03 CORRIDOR 90" x 84" SRG2A 2 3' - 9" 3' - 9" ALUM/GL ANOD F1 HM PNT -

C9-C04 CORRIDOR 42" x 84" SRG2A 1 3' - 6" ALUM/GL STN F1 HM PNT -

C9-C05 CORRIDOR 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-C06 CORRIDOR 90" x 84" SRG2A 2 3' - 9" 3' - 9" ALUM/GL ANOD F3 HM PNT -

C9-C07 CORRIDOR 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

C9-C08 CORRIDOR 90" x 84" SRG2A 2 3' - 9" 3' - 9" ALUM/GL ANOD F3 HM PNT -

C9-C09 CORRIDOR 84" x 84" SRG2A 2 3' - 6" 3' - 6" ALUM/GL ANOD F1 HM PNT -

DOOR SCHEDULE - WAREHOUSE

NUMBER ROOM NAME

DOOR FRAME

RATING

DETAIL

COMMENTS

SIZE

TYPE

LEAF

NUMBER

LEAF 1

SIZE

LEAF 2

SIZE MATERIAL FINISH TYPE MATERIAL FINISH DOOR HEAD DOOR JAMB

L1-00A STORAGE 60" x 80" F 2 3' - 0" 2' - 0" HM PNT F1 HM PNT -

L1-00B ELEC 36" x 80" F 1 3' - 0" HM PNT F1 HM PNT -

L1-00C ELEC 36" x 80" F 1 3' - 0" HM PNT F1 HM PNT -

L1-00D ELEC 36" x 80" F 1 3' - 0" HM PNT F1 HM PNT -

L1-00E TELECOM ROOM 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

L1-00G TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

L1-01 STORAGE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

L1-02 OPEN OFFICE 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -

L1-02A CLOSET 48" x 80" F 2 2' - 0" 2' - 0" WD STN F1 HM PNT -

L1-03 OPEN OFFICE 36" x 84" SRG2A 1 3' - 0" ALUM/GL ANOD ALUM ANOD -

L1-05 TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

L1-06 TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -

L1-07 OFFICE 36" x 84" SRG1 1 3' - 0" WD/GL STN F2 HM PNT -

L1-08 OFFICE 36" x 84" SRG1 1 3' - 0" WD/GL STN F2 HM PNT -

L1-09 OFFICE 36" x 84" SRG1 1 3' - 0" WD/GL STN F2 HM PNT -

L1-10 OFFICE 36" x 84" SRG1 1 3' - 0" WD/GL STN F2 HM PNT -

L1-11 CONFERENCE 36" x 84" SRG1 1 3' - 0" WD/GL STN F2 HM PNT -

L1-12 MECH 60" x 80" F 2 2' - 6" 2' - 6" WD STN F1 HM PNT -

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

R O

9'

8"

5'

0"

1'

RO

8' - 9 1/2"

EQ EQ

4 8

1/

2"

B

5'

0"

1'

R O

9'

8"

EQ EQRO

9' - 0"

8 4

1/

2"

R O

9'

8"

5'

0"

1'

EQ EQ

RO

8' - 8 1/2"

C

8 6

1/

2"

1'

5'

0"

8"

R O

9'

3' - 10 3/4" EQ 3' - 10 3/4"

RO

11' - 8 3/8"

D

6 8 6

1/

2"

1'

5'

0"

8"

R O

9'

EQ EQ

RO

7' - 5 1/2"

E

8 8

1/

2"

8"

R O

9'

1'

5'

0"

EQ EQ EQ

RO

12' - 2 1/8"

F

6 8 6

1/

2"

S1

26' - 6"

SCHEDULE

PER DOOR1' - 8"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"

SCHEDULE

PER DOOR

7'

2'

/2

4"

S2

7'

2'

31' - 10 3/4"

6' - 4" 2' - 4 1/2" 11"

SCHEDULE

PER DOOR 2' - 5 3/4"

SCHEDULE

PER DOOR 11" 2' - 4 1/2" 6' - 4" 3' - 2"

1 11

ALIGN WITH CENTER OF

PARTITION BEYOND

S3

3'

4'

EQ EQ

6' - 6"

3'

4'

4' - 0"

S4

/8

V

IF

P E

R D

O O

R S

C H

E D

U

LE

G

V

IF

4'

/2

8' - 6"

17' - 0" VIF

V

IF

8'

/8

2' - 6"

SCHEDULE

PER DOOR

EQ EQ

3'

R O

7'

/8

5'

/4

RO

8' - 0"

EQ EQ

H

2 2

S2.1

3' - 0"

7'

2'

4"

4 4 4 4 4 4 4

5555555

7'

/2

V

IF

V

IF

2'

18' - 11 1/4" VIF

2' - 3 1/2" 3' - 7 3/4" 2' - 10" 1' - 10" 1' - 10" 3' - 9"

1B

FOR TYPE 1B.1, PANELS

TO BE LOUVERS PER

MECHANICAL DRAWINGS

5'

/8

8'

/8

V

IF

V

IF

2'

/8

3' - 8" 2' - 10" 1' - 10" 1' - 10" 3' - 9"

16' - 8" VIF

5" 5"

5"

444444

5 5 5 5 5

1C

5'

V

IF

2'

V

IF

7'

/2

5' - 1"

7' - 8" VIF

5"

5" 5"

1D.1

4 4

V

IF

2'

M A

T C

H A

D

JA

C E

N T

6'

/4

V

IF

8' - 6" VIF

EQ EQ

A D

JA

C

E N

T

M A

T C

H

J

44 4 4

3' - 4" 3' - 9" 3' - 9" 3' - 9" EQ EQ 3' - 9" 3' - 9" 3' - 9" 3' - 10"

PER DOOR SCHEDULE

36' - 10 1/2"

4'

/8

3'

7/ 8"

1/

2"

P E

R D

O O

R S

C H

E D

U

LE

6 6 6 6

6666666666

6 6 6 6

K

A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT

ARE APPLICABLE.

B. EXTERIOR WINDOW PROFILES FOR SOUTH AND WEST ELEVATIONS ARE

REPRESENTATIVE OF INFORMATION FROM DRAWINGS PROVIDED TO

VALHALLA FROM VHA COR ON 02/10/2020 FROM VHA PROJECT #693-13-111.

WINDOW SIZES HAVE BEEN MODIFIED TO MATCH EXISTING OPENINGS AS

UNDERSTOOD BY VALHALLA AND ARE TO BE VERIFIED IN FIELD.

4'

3'

8' - 0"

EQ 3' - 4" EQ

11 1

S5

8 8

6 6

B1

RO

9' - 0"

EQ EQ

R O

9'

8"

5'

0"

1'

1/

2"

7' -6

5'

1"

5'

3/

8'

1/

1/

1"

0'

1"

0'

1"

0'

0'

1"

0'

1"

0'

9" 6"

3"

3"

1' -6

1'

6"

1/

2"

2' 1'

6"

1"

3' 2'

1'

3/ 4"

4'

2' 1'

1/

2"

6' 4'

2'

3/ 8"

8'

4'

3/

8' 4'

2'

1/ 4"

8'

4'

1/ 8"

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

C :\R ev it

\1 9.

_A

R C

H _R

_z m ill er 4N

R T

Z .r vt 4/

/2

:0

1:

A M

01-A47

WINDOW FRAME TYPES RENOVATE 9TH FLOOR MENTAL

HEALTH

1111 EAST END BLVD, WILKES-BARRE, PA 18711

693-19-106

01 & 17

04/18/2023 DR ZAM

100% CONSTRUCTION

DOCUMENTS

VEG 19.25 DWG 46 of 53 F

IN

A L

D R

A W

IN

G

S S

U B

M

IT

T A

L

GLAZING TYPE SCHEDULE

TYPE IMAGE DESCRIPTION

1 3/8" POLYCARBONATE, CLEAR

2 DOUBLE PANED, LOW-E, ARGON FILLED GLAZING, CLEAR

3 7/16" LAMINATED SPANDREL PANEL

DOUBLE PANED, LOW-E, ARGON FILLED GLAZING WITH 3/8"

POLYCARBONATE ON INTERIOR, CLEAR

INSULATED SPANDREL GLAZING UNIT, DOUBLE PANED, ARGON

FILLED

DOUBLE PANED, LOW-E, ARGON FILLED GLAZING WITH 3/8"

POLYCARBONATE BOTH PANES, CLEAR

3/8" POLYCARBONATE, BOD: LUMICOR LUMIFORM NATURAL -

COASTAL

OPERABLE PANE, GLAZING TYPE TO MATCH REST OF SYSTEM,

BOD: KAWNEER GLASSVENT WINDOWS FOR CURTAIN WALL

STOREFRONT/CURTAIN WALL SCHEDULE

TYPE FRAME TYPE HEAD DETAIL JAMB DETAIL SILL DETAIL

1B 2 E3/01-A48 E3/01-A48 SIM F3/01-A48

1B.1 2 E3/01-A48 E3/01-A48 SIM F3/01-A48

1C 2 E3/01-A48 E3/01-A48 SIM F3/01-A48

1D.1 2 E3/01-A48 E3/01-A48 SIM F3/01-A48

A 1 C5/01-A44 RE: 01-A41 RE: 01-A43

B 1 C5/01-A44 RE: 01-A41 RE: 01-A43

B1 1 F5/01-A44 RE: 01-A41 RE: 01-A43

C 1 <varies> <varies> <varies>

D 1 C1/01-A44 RE: 01-A41 RE: 01-A43

E 1 C1/01-A44 RE: 01-A41 RE: 01-A43

F 1 C1/01-A44 RE: 01-A41 RE: 01-A43

G 1 E7/01-A48 E5/01-A48 F5 & F7/01-A48

H 1 E7/01-A48 E5/01-A48 F5 & F7/01-A48

J 4

K 1 F1/01-A44 RE: 01-A41

S1 3 E1/01-A48 D7 & C7/01-A42 F1/01-A48

S2 3 E1/01-A48 C1/01-A48 F1/01-A48

S2.1 3 E1/01-A48 C1/01-A48 F1/01-A48

S3 3 C1/01-A48 C1/01-A48 C1/01-A48

S4 3 C1/01-A48 C1/01-A48 C1/01-A48

S5 3 C1/01-A48 C1/01-A48 C1/01-A48

STOREFRONT/CURTAIN WALL FRAME SCHEDULE

FRAME TYPE DESCRIPTION

1 BOD: KAWNEER 1600 WALL SYSTEM 1, 7 1/"2 D x 2 1/2" W. ANODIZED

2 MATCH MANUFACTURER, PRODUCT LINE, AND FINISH OF PROJECT

NO 693-13-111 - REPLACE EXTERIOR WINDOWS.

3 BOD: KAWNEER TRIFAB 400, 4" D x 1 3/4" W. ANODIZED

4 BOD: MATCH EXISTING NORTH WINDOW FRAMES

9TH FLOOR

92' - 3 3/4"

9TH FLOOR

92' - 3 3/4"

BASEMENT

-14' - 0"

9TH FLOOR

92' - 3 3/4"

9TH FLOOR

92' - 3 3/4"

0 100% CONSTRUCTION DOCUMENTS 04/18/2023

084113-B

088000-A

079200-C

079200-A

084113-B

079200-C

079200-A

092900-A

092216-A

042000-E

088000-A

A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT

ARE APPLICABLE.

B. EXTERIOR WINDOW PROFILES FOR…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .