05b - Drawings Architectural 3.pdf
PDF 32 MB Posted
- Attached to
- Y1DA--9th Floor MH Renovation WBVAMC
- Solicitation number
- 36C24425B0018
About this file
These architectural drawing files (01-A30 through 01-A53) detail the renovation plans for the 9th Floor Mental Health area at the Wilkes-Barre VA Medical Center, Project #693-19-106. The comprehensive set of drawings includes exterior elevations, interior layouts, wall sections, window and door schedules, finish schedules, and interior perspectives for a complete architectural renovation.
Key design elements include reconfiguring patient rooms, updating window systems with new glazing and integral blinds, installing new wall finishes (including rigid wall coverings and specialized paint), updating flooring with welded seam sheet flooring and luxury vinyl tiles, and redesigning nurse stations and common areas. The renovation focuses on creating a modern, functional mental health treatment environment with careful attention to materials, patient safety, and aesthetic considerations. The drawings are dated 04/18/2023 and prepared by Valhalla Engineering, with the project set to be a complete interior transformation of the 9th floor mental health wing.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8TH FLOOR
80' - 11 1/4"
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
11TH FLOOR
115' - 4 3/4"
ABCDEFGHJKLMN
R E
B
-A
R E
B
-A
FOLDED ELEVATION
A R
E A
O F
W O
R K
R E
B
-A
22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"22' - 0"17' - 3"4' - 9"5' - 1"16' - 11"
1B 1B
8TH FLOOR
80' - 11 1/4"
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
11TH FLOOR
115' - 4 3/4"
A B C D E F G H J K L M N
R E
F
-A
R E
F
-A
A R
E A
O F
W O
R K
F4
01-A37
22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0" 17' - 3" 4' - 9" 5' - 1" 16' - 11"
1B.1 1B 1C 1C 1C 1C 1C 1C 1C 1C
8TH FLOOR
80' - 11 1/4"
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
11TH FLOOR
115' - 4 3/4"
9 10 11 12 13 14
A R
E A
O F
W O
R K
22' - 0" 23' - 0" 16' - 0" 10' - 0" 17' - 0"
1D.1
A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT
ARE APPLICABLE.
B. EXTERIOR WINDOW PROFILES FOR SOUTH AND WEST ELEVATIONS ARE
REPRESENTATIVE OF INFORMATION FROM DRAWINGS PROVIDED TO
VALHALLA FROM VHA COR ON 02/10/2020 FROM VHA PROJECT #693-13-111.
WINDOW SIZES HAVE BEEN MODIFIED TO MATCH EXISTING OPENINGS AS
UNDERSTOOD BY VALHALLA AND ARE TO BE VERIFIED IN FIELD.
C. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL
INFORMATION.
EXTERIOR ELEVATION LEGEND
NEW LINE TYPE
EXISTING LINE TYPE
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
0:
A M
01-A30
EXTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 30 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
1/8" = 1'-0"
NORTH ELEVATION - WEST
B1
1/8" = 1'-0"
SOUTH ELEVATION - WEST
F1
1/8" = 1'-0"
WEST ELEVATION
D5
1 INSTALL NEW LAMINATED GLAZING AND SPANDREL PANELS IN EXISTING
WINDOW FRAME TO MATCH EXISTING LAYOUT. WINDOWS TO HAVE
INTEGRAL BLINDS BETWEEN LAYERS OF GLAZING.
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
ZMiller Image
8TH FLOOR
80' - 11 1/4"
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
11TH FLOOR
115' - 4 3/4"
1011121314
A R
E A
O F
W O
R K
B5
01-A36
D E F
8TH FLOOR
80' - 11 1/4"
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
11TH FLOOR
115' - 4 3/4"
NOPQRSTUV
R E
B
-A
R E
B
-A
3 1 1 1
A R
E A
O F
W O
R K
F1
01-A37
D5
01-A36
C B1 B A
F5
01-A36
8TH FLOOR
80' - 11 1/4"
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
11TH FLOOR
115' - 4 3/4"
M N O P Q R S T U V
R E
F
-A
A R
E A
O F
W O
R K
D5
01-A36
A B B1 C 1C 1C 1C 1C 1C 1C
F5
01-A36
A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT
ARE APPLICABLE.
B. EXTERIOR WINDOW PROFILES FOR SOUTH AND WEST ELEVATIONS ARE
REPRESENTATIVE OF INFORMATION FROM DRAWINGS PROVIDED TO
VALHALLA FROM VHA COR ON 02/10/2020 FROM VHA PROJECT #693-13-111.
WINDOW SIZES HAVE BEEN MODIFIED TO MATCH EXISTING OPENINGS AS
UNDERSTOOD BY VALHALLA AND ARE TO BE VERIFIED IN FIELD.
C. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL
INFORMATION.
EXTERIOR ELEVATION LEGEND
NEW LINE TYPE
EXISTING LINE TYPE
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
0:
A M
01-A31
EXTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 31 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
1/8" = 1'-0"
EAST ELEVATION
D5
1/8" = 1'-0"
NORTH ELEVATION - EAST
B1
1/8" = 1'-0"
SOUTH ELEVATION - EAST
F1
1 NEW POLYCARBONATE GLAZING IN EXISTING WINDOW FRAME. WINDOWS
TO HAVE INTEGRAL BLINDS BETWEEN LAYERS OF GLAZING.
2 PREFINISHED ALUMINUM SUN SHADE; FINISH TO MATCH MULLIONS
3 NEW WINDOW SYSTEM, INFILL PARTIAL WALL TO NEW SILL HEIGHT
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
BASEMENT
-14' - 0"
H
BASEMENT
-14' - 0"
TUV
G
EXTERIOR ELEVATION LEGEND
NEW LINE TYPE
EXISTING LINE TYPE
A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
B. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL
INFORMATION.
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
17-A32
EXTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 32 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
1/8" = 1'-0"
EAST WAREHOUSE ELEVATION
F5
1/8" = 1'-0"
NORTH WAREHOUSE ELEVATION
D5
1 STEEL STAIR, GUARD AND HANDRAIL
2 NEW AIR HANDLING UNIT; RE MECHANICAL
3 EXISTING AIR HANDLING UNIT
4 INSTALL WINDOW PANE IN DEMOLISHED EXHAUST FAN OPENING. MATCH
EXISTING WINDOW DESIGN AND GLAZING TYPE
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
OPEN TO
C9-27A
OPEN TO
C9-27
18 34 24
36 34 24
36 34 24
36 18 12
36 30 12
18 30 12
8' - 4 1/2"
F
F 900
34 25
34 25
A. REFER TO 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE APPLICABLE.
B. REFER TO 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING HEIGHTS OF
FIXTURES AND ACCESSORIES
C. REFER TO 01-A40 FOR MILLWORK DETAILS
D. REFER TO 01-A46 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND
FRAME DETAILS
E. REFER TO 01-A47 FOR WINDOW TYPES
F. REFER TO 01-A50 FOR FINISH SCHEDULE AND LEGEND.
36 34 24
12 34 24
36 18 12
12 30 12
2' - 3"
F
F900
34 25
32 25
34 25
34 25
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A33
INTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 33 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
3/8" = 1'-0"
C9-27 - SOUTH ELEVATION
C2
3/8" = 1'-0"
C9-68A - EAST ELEVATION
F7
3/8" = 1'-0"
C9-65 - WEST ELEVATION
E73/8" = 1'-0"
C9-64 - SOUTH ELEVATION
E5
3/8" = 1'-0"
C9-64 - EAST ELEVATION
F5
3/8" = 1'-0"
C9-33 - WEST ELEVATION
C7
3/8" = 1'-0"
C9-27A - NORTH ELEVATION
E2
3/8" = 1'-0"
C9-27 - NORTH ELEVATION
B2
3/8" = 1'-0"
C9-15A - EAST ELEVATION
B7
3/8" = 1'-0"
C9-15A - NORTH ELEVATION
C5
3/8" = 1'-0"
C9-15A - WEST ELEVATION
B5
3/8" = 1'-0"
C9-42 - SOUTH ELEVATION
F2
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
30 34 24
36 34 24
21 34 24
FF222
36 34 24
36 34 24
33 34 24
54 12
9' - 0"
F211
24 34 24 2"
F
A. REFER TO 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE APPLICABLE.
B. REFER TO 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING HEIGHTS OF
FIXTURES AND ACCESSORIES
C. REFER TO 01-A40 FOR MILLWORK DETAILS
D. REFER TO 01-A46 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND
FRAME DETAILS
E. REFER TO 01-A47 FOR WINDOW TYPES
F. REFER TO 01-A50 FOR FINISH SCHEDULE AND LEGEND.
36 34 24
18 34 24
18 34 24
36 34 24
36 30 12
36 30 12
36 30 12
36 30 12
3' - 0"
FF
F F
36 34 24
18 34 24
36 34 24
36 34 24
36 34 24
3' - 5 1/4" F211
21 34 24
36 34 24
36 34 24
30 34 24
30 30 12
27 30 12
36 18 12
36 30 12
21 30 12
3' - 3"
36 34 24
36 34 24
36 30 12
36 18 12
1 1/2"
F
36 34 24
36 34 24
24 34 24
8' - 0"
30 18
1 3/4"
1 3/4"
36 42 24
36 42 24
36 42 24
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A34
INTERIOR ELEVATIONS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 34 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
3/8" = 1'-0"
C9-22 - NORTH ELEVATION
F53/8" = 1'-0"
C9-22 - SOUTH ELEVATION
F43/8" = 1'-0"
C9-22 - WEST ELEVATION
F2
3/8" = 1'-0"
L1-104 - SOUTH ELEVATION
D73/8" = 1'-0"
L1-111 - EAST ELEVATION
D53/8" = 1'-0"
C9-28 - SOUTH ELEVATION
D2
3/8" = 1'-0"
C9-35A - EAST ELEVATION
C73/8" = 1'-0"
C9-35A - NORTH ELEVATION
C53/8" = 1'-0"
C9-35A - WEST ELEVATION
C43/8" = 1'-0"
C9-40 - EAST ELEVATION
C2
3/8" = 1'-0"
L1-104 - NORTH ELEVATION
B73/8" = 1'-0"
C9-38 - WEST ELEVATION
B53/8" = 1'-0"
C9-25 - SOUTH ELEVATION
B4
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
3/8" = 1'-0"
C9-35 - ISLAND ELEVATION
F7
RWC-2RWC-2
2' - 0"
RWC-4RWC-2
2' - 0"
RWC-2RWC-2
2' - 0"
RWC-2
RWC-2
1' - 8 7/8"
RWC-2RWC-3 RWC-2RWC-2
2' - 0"
RWC-4RWC-2
2' - 0"
RWC-2 RWC-3
RWC-3 RWC-2RWC-2
2' - 0"
RWC-4RWC-2
2' - 0"
RWC-2
RWC-2
1' - 8 7/8"RWC-2 RWC-3RWC-3
RWC-3 RWC-2RWC-2
2' - 0"
RWC-4RWC-2
2' - 0"
RWC-2 RWC-3RWC-2 RWC-3
RWC-3
RWC-2
2' - 0"
RWC-2 RWC-3
RWC-3 RWC-2RWC-2
2' - 0"
RWC-2
1' - 10 3/8" RWC-2 RWC-3RWC-2RWC-2
2' - 0"
RWC-4RWC-2
2' - 0"
RWC-2 RWC-3RWC-3
RWC-2RWC-3 RWC-2 RWC-3
A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
B. REFER TO 01-A50 FOR FINISH SCHEDULE AND LEGEND.
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A35
INTERIOR FINISH ELEVATIONS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 ZM AW
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 35 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
3/16" = 1'-0"
FINISH ELEVATION - CORRIDORS C9-C01 & C9-C03 - SOUTH
F1
3/16" = 1'-0"
FINISH ELEVATION - CORRIDORS C9-C01 & C9-C03 - NORTH
E1
3/16" = 1'-0"
FINISH ELEVATION - CORRIDOR C9-C06 - NORTH
C43/16" = 1'-0"
FINISH ELEVATION - CORRIDORS C9-C08 & C9-C09 - NORTH
C1
3/16" = 1'-0"
FINISH ELEVATION - CORRIDOR C9-C06 - SOUTH
D43/16" = 1'-0"
FINISH ELEVATION - CORRIDORS C9-C08 & C9-C09 - SOUTH
D1
3/16" = 1'-0"
FINISH ELEVATION - LOBBY C9-26 - SOUTH
B4
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
T U V
D5
01-A36
4' - 1 1/8"22' - 0"20' - 7 1/2"
F5
01-A36
01-A43
B6
01-A44
F1
01-A44
C1
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
11121314 B5
01-A36
01-A44
F5
01-A43
D3
01-A44
F5
OPP
01-A43
D6
A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION
REGARDING INTERIOR WALL CONSTRUCTION.
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
11121314 B5
01-A36
01-A44
C5
01-A43
F3
01-A43
F6
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A36
BUILDING SECTIONS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 36 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
1/4" = 1'-0"
BUILDING SECTION 1 @ EAST SUNROOM
B5
1/4" = 1'-0"
BUILDING SECTION 2 @ COURTYARD
D5
1/4" = 1'-0"
BUILDING SECTION 2 @ EAST SUNROOM
F5
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
BASEMENT
-14' - 0"
01-A43
D1
01-A48
F5
SIM
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
01-A43
F1
01-A48
F3
A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION
REGARDING INTERIOR WALL CONSTRUCTION.
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
9TH FLOOR
92' - 3 3/4"
10TH FLOOR
103' - 8 1/4"
01-A48
E3
01-A48
F3
SIM
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A37
WALL SECTIONS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 37 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
3/4" = 1'-0"
SECTION AT NEW WAREHOUSE STOREFRONT ENTRY
F63/4" = 1'-0"
SECTION AT DAY/TV - SOUTH WALL
F4
1 NEW WINDOW SYSTEM. WINDOWS TO HAVE INTEGRAL BLINDS BETWEEN
LAYERS OF GLAZING AND INTERIOR LAYER SHALL BE LAMINATED GLASS
2 EXISTING EXTERIOR MASONRY WALL
3 SCHEDULED CEILING, RE: REFLECTED CEILING PLAN
4 SCHEDULED FINISH FLOOR AND WALL BASE, RE: FINISH PLANS
5 EXISTING CONCRETE FLOOR STRUCTURE
6 NEW STOREFRONT SYSTEM AND DOOR TO ALIGN WITH EXISTING WINDOWS
AND MULLIONS
7 STEEL GUARD
3/4" = 1'-0"
SECTION AT MEN'S PATIENT ROOM C9-13 - NORTH WALL
F1 3/4" = 1'-0"
SECTION AT PATIENT TOILET ROOM C9-23A - SOUTH WALL
F3
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
A
LI
G N
A
LI
G N
A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
C. REFER TO SHEET 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING
HEIGHTS OF FIXTURES AND ACCESSORIES.
D. ALIGN NEW WALLS WITH ADJACENT EXISTING WALLS WHERE NEW WALL
EXTENDS IN THE SAME DIRECTION.
E. ALIGN CENTER OF DEMISING WALLS OR FINISH FACE OF CHASE WALLS
WITH CENTER OF WINDOW MULLION, UNLESS NOTED OTHERWISE.
F. PARTITIONS TO BE TYPE S3A, UNLESS NOTED OTHERWISE. FURRING
ALONG EXTERIOR WALLS TO BE S2B.1, UNLESS NOTED OTHERWISE.
G. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL
INFORMATION.
C
C9-68A
TOILET
C9-66A
TOILET
6' - 7 3/8" 1' - 5" 11 1/8"
4'
/8
3'
4'
/8
01-A33 F7
9 5/8"
S3B.1
S3B.1
S3B.1
S3B.1 S3B.1
S3B.1
1'
/4
3'
S3B.1
S3B.1
S3B.1
S3B.1
C
C9-67A
TOILET
6' - 3 5/8" 9 3/4"
5' - 0" 1' - 4 1/2"
4'
1/ 4"
3'
3'
0"
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
8"
5'
S3B.1 S3B.1
S3B.1
S3B.1
S3B.1
F
C9-49A
TOILET
7' - 10 1/8" 4' - 0"
S8A.A
S3B.1
3'
5'
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
G
C9-43A
TOILET
C9-42
STAFF TOILET
S3B.1
S3B.1
S3B.1
S6A
S6A
6' - 8 1/8"
4'
/8
6'
/2
3'
"1' - 0 1/8"
01-A33
F2
4' - 0"
C9-44A
TOILET
C9-41A
TOILET
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
3'
1/ 2"
3'
4'
/8
3'
9 3/4"
3' - 0"
3' - 0"
11" 9 3/4"
S3B.1
L M
F3
01-A37
C9-24A
TOILET
C9-25A
TOILET
S3B.1
S3B.1
S6A.A21
S3B.1
S3B.1
3'
7/ 8"
3'
/8
4'
/8
2'
7 1/2"
5' - 2 7/8" 1' - 5" 6 3/8"
1' - 0 1/8"
3' - 2 7/8"
S3B.1
S3B.1
S3B.1
S3B.2
S6A
S3A.A21
O
C9-20A
TOILET
C9-18A
TOILET
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1 S3B.1
S3B.1
S3B.1
S3B.1
S3B.1 S3B.1
S3B.1 F1B
S3B.1
3' - 0"
9 3/4" 4' - 7" 1' - 9 3/8" S3B.1
F1B
9 3/4"
3'
/2
3'
4'
/4
3'
3' - 0"
Q
C9-15A
TOILET
5'
/4
3'
1' - 0 1/8" 4' - 3 1/4"
S3B.1
S3B.1
S3B.1
S3B.1
01-A33
C5
B7B5
01-A41
B5
Q
C9-12A
TOILET
C9-14A
TOILET
S3B.1
S3B.1
S3B.1
S3B.1S3B.1
S3B.1
S3B.1
S3B.1
S3B.1 S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
3'
1/ 4"
3'
4'
/8
3'
/4
1' - 5"
3' - 0"
3' - 0"
S6A
S6A
S
C9-07
OFFICE
C9-05
TOILET
C9-08A
TOILET
C9-06
4'
6'
/8
S3B.1
S3B.1S3B.1
5' - 0" 1' - 4 1/2" 8' - 4 1/4"
6' - 9 1/4" 1' - 8 1/2"
2'
7'
/2
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1 S3B.1
S3B.1
S3B.1
S6A
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A38
ENLARGED FLOOR PLANS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 38 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L3/8" = 1'-0"
ENLARGED RESTROOM PLAN - C9-66A AND C9-68A
F7
3/8" = 1'-0"
ENLARGED RESTROOM PLAN - C9-67A
B7
3/8" = 1'-0"
ENLARGED RESTROOM PLAN - C9-49A
D7
3/8" = 1'-0"
ENLARGED RESTROOM PLAN - C9-42 AND C9-43A
F5
3/8" = 1'-0"
ENLARGED RESTROOM PLAN - C9-41A AND C9-44A
D5
3/8" = 1'-0"
ENLARGED RESTROOM PLAN - C9-24A AND C9-25A
F33/8" = 1'-0"
ENLARGED RESTROOM PLAN - C9-18A AND C9-20A
F1
3/8" = 1'-0"
ENLARGED RESTROOM PLAN - C9-15A
D33/8" = 1'-0"
ENLARGED RESTROOM PLAN - C9-12A AND C9-14A
D1
3/8" = 1'-0"
ENLARGED RESTROOM PLAN - C9-05 AND C9-08A
B3
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
DN
ALIGN
O
C9-22
SERVING KITCHEN
01-A34
F4
F2
F5
S3B.1
2' - 1"
S3B.1
S3B.1
S3B.1
4'
/8
L M
C9-35A
LOCKERS
S3B.1
1'
5'
/8
3'
3'
1"
2' - 4 3/4"
1' - 11 3/8" 7' - 8" 1' - 6 5/8" 2' - 4 1/4"
120°
S3B.1 S3B.1S3B.1F1BS3B.1
S3B.1
1' - 6"
S3B.1
01-A34
C5
C7C4
A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
C. REFER TO SHEET 01-I4 ACCESSIBILITY GUIDELINES FOR MOUNTING
HEIGHTS OF FIXTURES AND ACCESSORIES.
D. ALIGN NEW WALLS WITH ADJACENT EXISTING WALLS WHERE NEW WALL
EXTENDS IN THE SAME DIRECTION.
E. ALIGN CENTER OF DEMISING WALLS OR FINISH FACE OF CHASE WALLS
WITH CENTER OF WINDOW MULLION, UNLESS NOTED OTHERWISE.
F. PARTITIONS TO BE TYPE S3A, UNLESS NOTED OTHERWISE. FURRING
ALONG EXTERIOR WALLS TO BE S2B.1, UNLESS NOTED OTHERWISE.
G. REFER TO WINDOW TYPES FOR DIMENSIONS AND ADDITIONAL
INFORMATION.
T
C9-02
HAC
C9-04A
TOILET
S2B.1
S3B.1
1' - 4 7/8" 3' - 7 1/4" 3' - 6 3/8"
6'
/4
4'
/8
S6A
S3B.1
S3B.1
S3B.1
S3B.1
F6
01-A37
G
J
7' - 1 3/4" 4' - 0" F1
01-A40
D
01-A33 F5
F1
01-A40
2'
S4
R
' - 1
3'
2' - 8 3/8"
5' - 5 13/16"
2' - 6"
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A39
ENLARGED FLOOR PLANS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 39 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
1 INFILL EXISTING WINDOW OPENING WITH WALL TO MATCH ADJACENT
3/8" = 1'-0"
ENLARGED FLOOR PLAN - C9-22
F4 3/8" = 1'-0"
ENLARGED FLOOR PLAN - C9-35A
F7
3/8" = 1'-0"
ENLARGED FLOOR PLAN - C9-02 AND C9-03
D7
3/8" = 1'-0"
ENLARGED WAREHOUSE STAIR PLAN
F2
3/8" = 1'-0"
ENLARGED PLAN - C9-27 DESK
D4
3/8" = 1'-0"
ENLARGED PLAN - C9-64 DESK
B4
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
2"
60°
1' - 0"
7'
123200-A
123200-E
2"
4"
096513-A
123200-E
123200-A
061000-D
123600-A
123600-B
123200-G
061000-C
123600-A
061000-D
123600-C
096513-A
061000-C
2'
0"
2' - 1"
A. REFER TO FINISH LEGEND AND FINISH SCHEDULE FOR SPECIFIC FINISH
INFORMATION.
B. ALL MILLWORK/ CASEWORK CONSTRUCTION SHALL MEET AWI PREMIUM
STANDARDS, UNLESS NOTED OR SPECIFIED OTHERWISE.
C. ALL EXPOSED MILLWORK/ CASEWORK SURFACES SHALL BE FINISHED W/
PLASTIC LAMINATE TO MATCH ADJACENT PLASTIC LAMINATE SURFACES,
UNLESS NOTED OTHERWISE.
D. ALL CASEWORK INTERIORS SHALL BE WHITE MELAMINE, UNLESS NOTED
OTHERWISE.
E. ALL FILLER PANELS SHALL BE 1-1/2 INCH WIDE MINIMUM, FINISHED TO
MATCH ADJACENT FINISH SURFACES, AND SCRIBED TO FIT ADJACENT
WALL, UNLESS NOTED OTHERWISE.
F. ALL BACKSPLASH FINISHES SHALL MATCH COUNTERTOP MATERIAL AND
FINISH, UNLESS NOTED OTHERWISE. PLASTIC LAMINATE
SIDE/BACKSPLASHES TO HAVE SELF EDGE LAMINATE, UNLESS NOTED
OTHERWISE.
G. CONTRACTOR SHALL APPLY CLEAR MILDEW RESISTANT SILICONE SEALANT
WHERE BACKSPLASH MEETS WALL AND COUNTERTOP.
H. THE UNDERSIDE OF COUNTERTOPS WITH KNEE OPENINGS, MUST HAVE A
WHITE MELAMINE FINISH, UNLESS NOTED OTHERWISE.
I. WATER AND SUPPLY DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL
BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST
CONTACT. THERE SHALL BE NO SHARP OF ABRASIVE SURFACES UNDER
LAVATORIES AND SINKS.
4"
096513-A
123200-A
061000-D
123600-A
123600-B
123200-G
061000-C
224000-D
1'
1' - 6"
3"
123200-A
061000-C
9TH FLOOR
92' - 3 3/4"
1'
092216-A
088000-B
123600-C
096513-A
061000-D
123200-A
092216-A092900-A
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A40
MILLWORK SECTIONS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 40 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L1 1/2" = 1'-0"
CASEWORK SECTION - CDS 301 & 302
F3 1 1/2" = 1'-0"
CASEWORK SECTION - CDS 211 & 222
F71 1/2" = 1'-0"
CASEWORK SECTION - CDS 900
F5
061000-C WOOD BLOCKING
061000-D PLYWOOD SHEATHING
088000-B SECURITY GLAZING
092216-A METAL STUDS, RE WALL TYPE
092900-A GYPSUM BOARD
096513-A RESILIENT BASE, RE FINISH SCHEDULE
123200-A PLASTIC LAMINATE CASEWORK
123200-E ADJUSTABLE SHELF
123200-G WIRE PULL
123600-A PLASTIC LAMINATE COUNTERTOP
123600-B PLASTIC LAMINATE BACKSPLASH
123600-C COUNTER BRACKET
224000-D HAND SINK, RE PLUMBING
1 1/2" = 1'-0"
CASEWORK SECTION - CDS 152
D7
1 1/2" = 1'-0"
CORRIDOR BENCH DETAIL
B7
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
1 1/2" = 1'-0"
CASEWORK SECTION - NURSE STATION
F1
ALIGN
1' - 5"
2'
0"
074000-C
079200-A
084113-B
079200-C
072113-B
092216-A
061000-B
088000-A
/4
072727-A
U
1' - 5" 1' - 5"
3'
4'
/4
EQ 1" EQ
074000-C
079200-A
084113-B
079200-C
061000-C
072113-B
061000-B
092216-A
088000-A
2'
1"
072727-A
V
2' - 10"
4'
/4
EQ 1" EQ
074000-C
084113-B
061000-C
092216-A
061000-B
079200-C
079200-A
088000-A
2'
1"
072727-A
V
3'
/4
1' - 6" 1' - 4"
E Q
1" E
Q
079200-A
084113-B
074000-C
061000-B
061000-C
079200-C
088000-A
072727-A
RE FLOOR PLAN
EQ EQ
092900-D
092216-A
092900-A
084113-B
3/
8"
088000-A
RE FLOOR PLAN
S8A.A
S8A.A
S8A.A
EQ EQ
084113-B
092900-A
092216-A
088000-A
1'
RE FLOOR PLAN
EQ EQ
S3A
S3A S3A
X
10 1/2"
2'
/8
S 3B
.1
S3B.1
S 3B
.1
S3B.1
4' - 6"
6"95°
4"
084113-B
079200-C
074000-C
061000-B
079200-A
092216-A
1' - 5"
088000-A
072727-A
14S3B.1
092900-D
EQ EQ088000-A
084113-B
092900-A
092216-A
A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
B. REFER TO FLOOR PLANS AND ENLARGED PLANS FOR ADDITIONAL
PARTITION TYPES.
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
######-AKEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A41
PLAN DETAILS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 41 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
1 1/2" = 1'-0"
COLUMN DETAIL
F1 1 1/2" = 1'-0"
COLUMN U-14 DETAIL
F4 1 1/2" = 1'-0"
COLUMN V-14 DETAIL
F7
1 1/2" = 1'-0"
COLUMN V-13 DETAIL
D71 1/2" = 1'-0"
PLAN DETAIL - PARTITION TO NEW WINDOW
D3
1 1/2" = 1'-0"
PLAN DETIAL - DEMISING WALL TO WINDOW
B7
1 1/2" = 1'-0"
PLAN DETAIL - PARTITION TO EXISTING WINDOW
D1 1 1/2" = 1'-0"
PLAN DETAIL - L1-104
D5
1 1/2" = 1'-0"
PLAN DETAIL - TYPICAL PATIENT ROOM DOOR
B2
1 1/2" = 1'-0"
COLUMN U/V-14 DETAIL
F5
061000-B FIRE-RETARDANT-TREATED PLYWOOD SHEATHING
061000-C WOOD BLOCKING
072113-B EXTRUDED-POLYSTYRENE BOARD INSULATION WITH TAPED AND
SEALED SEAMS
072727-A FLUID-APPLIED MEMBRANE AIR BARRIER, VAPOR RETARDING
074000-C METAL WALL PANELS
079200-A JOINT SEALANT
079200-C BACKER ROD AND SEALANT
084113-B ALUMINUM-FRAMED STOREFRONT SYSTEM
088000-A GLAZING PER GLAZING SCHEDULE
092216-A METAL STUDS, RE WALL TYPE
092900-A GYPSUM BOARD
092900-D METAL TRIM
1 1/2" = 1'-0"
PLAN DETAIL - QUIET ROOM WINDOW
B5
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
1' - 0"
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
S3B.1
1'
/8
084113-B
9 3/4"
1'
/4
1/
2"
S3B.1
S3B.1
S3B.1
084113-B
5"
102600-K
092216-A
092900-A
A. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
B. REFER TO FLOOR PLANS AND ENLARGED PLANS FOR ADDITIONAL
PARTITION TYPES.
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
######-AKEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A42
PLAN DETAILS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 42 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
1 1/2" = 1'-0"
PLAN DETAIL - DOOR C9-08
F7
1 1/2" = 1'-0"
PLAN DETAIL - DOOR C9-16
D7
1 1/2" = 1'-0"
PLAN DETAIL - DOOR C9-16A
C7
1 1/2" = 1'-0"
PLAN DETAIL - TYP CORRIDOR DOOR
B7
084113-B ALUMINUM-FRAMED STOREFRONT SYSTEM
092216-A METAL STUDS, RE WALL TYPE
092900-A GYPSUM BOARD
102600-K END GUARD, RE FINISH LEGEND
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
9TH FLOOR
92' - 3 3/4"
072200-B
077600-A
092900-B
092216-B
076000-A
079200-A 088000-A
084113-B
079200-C
061000-C
079200-A
6"
PER RCP
079200-C
084113-B
088000-A
079200-A
092900-A
092216-A
095100-A
6"
PER RCP
E Q
E Q
084113-B
079200-C 079200-A
092216-A
092900-A
088000-A
A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION
REGARDING INTERIOR WALL CONSTRUCTION.
9TH FLOOR
92' - 3 3/4"
061000-B
096513-A
092900-A
072113-B
076000-A
079200-A088000-A
084113-B
079200-C
061000-C
9TH FLOOR
92' - 3 3/4"
2"
061000-B
096513-A
092900-A
072113-B
092216-A
079200-A 088000-A
084113-B
079200-C
061000-C
076000-A
051200-E
9TH FLOOR
92' - 3 3/4"
072200-B
079200-A
092216-B
092900-A
076000-A
079200-A
088000-A
084113-B
079200-C
061000-C
076000-A 033000-G
9TH FLOOR
92' - 3 3/4"
V
072200-B
079200-A
092216-B
092900-B
076000-A
079200-A
088000-A
084113-B
079200-C
061000-C
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A43
SECTION DETAILS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 43 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
1 1/2" = 1'-0"
DETAIL @ COURTYARD SOUTH STOREFRONT SILL
D31 1/2" = 1'-0"
CEILING DETAIL AT WAREHOUSE STOREFRONT
D1
1 1/2" = 1'-0"
SECTION DETAIL - CEILING TO MULLION
F1
033000-G CONCRETE WALL
051200-E STEEL PLATE, RE STRUCTURAL
061000-B FIRE-RETARDANT-TREATED PLYWOOD SHEATHING
061000-C WOOD BLOCKING
072113-B EXTRUDED-POLYSTYRENE BOARD INSULATION WITH TAPED AND
SEALED SEAMS
072200-B TAPERED ROOF INSULATION
076000-A PREFINISHED SHEET METAL FLASHING
077600-A ROOFTOP TURF PAVER SYSTEM
079200-A JOINT SEALANT
079200-C BACKER ROD AND SEALANT
084113-B ALUMINUM-FRAMED STOREFRONT SYSTEM
088000-A GLAZING PER GLAZING SCHEDULE
092216-A METAL STUDS, RE WALL TYPE
092216-B METAL HAT CHANNEL, RE WALL TYPE
092900-A GYPSUM BOARD
092900-B GLASS MAT GYPSUM BOARD
095100-A ACOUSTICAL PANEL CEILING, RE FINISH SCHEDULE
096513-A RESILIENT BASE, RE FINISH SCHEDULE
1 1/2" = 1'-0"
DETAIL @ SUNROOM SOUTH STOREFRONT SILL
F3 1 1/2" = 1'-0"
DETAIL @ SUNROOM NORTH STOREFRONT SILL
F6
1 1/2" = 1'-0"
DETAIL @ COURTYARD NORTH STOREFRONT SILL
D6
1 1/2" = 1'-0"
DETAIL @ COURTYARD EAST SUNROOM SILL
B6
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
A. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
B. REFER TO SHEET 01-I3 FOR ADDITIONAL GENERAL NOTES THAT ARE
APPLICABLE.
C. REFER TO WALL TYPES SCHEDULE SHEET FOR MORE INFORMATION
REGARDING INTERIOR WALL CONSTRUCTION.
10TH FLOOR
103' - 8 1/4"
1'
1/ 2"
1/
2" 1'
/2
3' - 10 7/8" 1' - 10 3/4"
6"
6"
6"
6"
6"
074000-C
072200-D072200-B
074000-D
061000-B
092216-A
TYP
70°
074000-L 074000-H074000-H
072727-A
075423-A
6"
6"
6"
6"
074000-C
061000-B
092216-A
072113-B
072200-D
072200-B
074000-D
079200-C
061000-C
084113-B
088000-A
079200-A
092900-A
074000-L 074000-H
1'
1/ 2"
1'
3' - 10 7/8" 1' - 10 3/4"
075423-A
10TH FLOOR
103' - 8 1/4"
U
074000-D
074000-C
061000-B
092216-A
092900-A
072113-B
092216-A
084113-B
061000-C
079200-C
079200-A
072200-D
072200-B
088000-A
074000-H
5 3/8"
075423-A
10TH FLOOR
103' - 8 1/4"
V
6"
6"
6"
6"
6"
074000-C
061000-B
092216-A
079200-C
084113-B
088000-A 061000-C
079200-A
074000-H 074000-L
074000-D
072200-D
072200-B
1' - 4" 2' - 8 5/8"
1'
5/ 8"
1'
/8
075423-A
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
######-AKEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A44
SECTION DETAILS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 43 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
061000-B FIRE-RETARDANT-TREATED PLYWOOD SHEATHING
061000-C WOOD BLOCKING
072113-B EXTRUDED-POLYSTYRENE BOARD INSULATION WITH TAPED AND
SEALED SEAMS
072200-B TAPERED ROOF INSULATION
072200-D GLASS MAT, WATER-RESISTANT GYPSUM ROOF BOARD
072727-A FLUID-APPLIED MEMBRANE AIR BARRIER, VAPOR RETARDING
074000-C METAL WALL PANELS
074000-D PARAPET CAP BY WALL PANEL MANUFACTURER
074000-H METAL SOFFIT PANEL
074000-L PERFORATED METAL SOFFIT PANEL
075423-A THERMOPLASTIC POLYOLEFIN (TPO) ROOFING SYSTEM
079200-A JOINT SEALANT
079200-C BACKER ROD AND SEALANT
084113-B ALUMINUM-FRAMED STOREFRONT SYSTEM
088000-A GLAZING PER GLAZING SCHEDULE
092216-A METAL STUDS, RE WALL TYPE
092900-A GYPSUM BOARD
1 1/2" = 1'-0"
DETAIL @ COURTYARD ROOF EAVE (SOUTH)
F5
1 1/2" = 1'-0"
DETAIL @ EAST SUNROOM ROOF EAVE
C5
1 1/2" = 1'-0"
DETAIL @ EAST SUNROOM STOREFRONT HEAD
F1
1 1/2" = 1'-0"
DETAIL @ COURTYARD ROOF EAVE (EAST)
C1
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
5/8" GYPSUM WALL BOARD EACH SIDE (ABUSE
RESISTANT IN ALL PATIENT ROOMS)
CONTINUOUS SEALANT AT SOUND / SMOKE WALLS
CEILING AS INDICATED ON RCP
CONT FULL-HEIGHT SOUND BATT INSULATION TO
MEET STC RATING
CONT METAL RUNNERS TOP AND BOTTOM
SECTION VIEW
RE: SCHED
METAL STUDS WITH HORIZONTAL BRACING AS REQ'D
# SEE SCHEDULE
GYPSUM BOARD (09 29 00) ON BOTH SIDES OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO UNDERSIDE OF
FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.
PARTITION TYPE
S3A
S3A.A S6A
STUD SIZE
3-5/8" 3-5/8"
6"
STC RATING
N/A
N/A
FRR TEST
N/A
UL XXX
N/A
HEAD DETAIL
BASE DETAIL
S##.X
PARTITION WIDTH
4-7/8" 4-7/8" 7-1/4"
BOTTOM OF
FLOOR/ROOF CONST
FINISHED CEILING HEIGHT
FLOOR/ROOF CONST
FINISHED FLOOR
5/8" GYPSUM WALL BOARD EACH SIDE (ABUSE
RESISTANT IN ALL PATIENT ROOMS)
CONTINUOUS SEALANT AT SOUND / SMOKE WALLS
CEILING AS INDICATED ON RCP
CONT FULL-HEIGHT SOUND BATT INSULATION TO
MEET STC RATING
CONT 8" METAL RUNNERS TOP AND BOTTOM
SECTION VIEW
RE: SCHED
METAL STUDS WITH HORIZONTAL BRACING AS REQ'D
# SEE SCHEDULE
GYPSUM BOARD (09 29 00) ON BOTH SIDES OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO UNDERSIDE OF
FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.
PARTITION TYPE
S8A.A
STUD SIZE
(2) 3-5/8"
STC RATING
FRR TEST
N/A
HEAD DETAIL
BASE DETAIL
S8A.A
PARTITION WIDTH
9-1/4"
BOTTOM OF
FLOOR/ROOF CONST
FINISHED CEILING HEIGHT
FLOOR/ROOF CONST
FINISHED FLOOR
5/8" GYPSUM WALL BOARD ROOM SIDE (ABUSE
RESISTANT IN ALL PATIENT ROOMS)
CONTINUOUS SEALANT AT SOUND / SMOKE WALLS
CEILING AS INDICATED ON RCP
CONT FULL-HEIGHT SOUND BATT INSULATION TO
MEET STC RATING
CONT METAL RUNNERS TOP AND BOTTOM
SECTION VIEW
METAL STUDS WITH HORIZONTAL BRACING AS REQ'D
GYPSUM BOARD (09 29 00) ON ROOM SIDE OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO ABOVE CEILING.
PARTITION TYPE
S2B.1 S3B.1
STUD SIZE
2-1/2" 3-5/8"
STC RATING
N/A N/A
FRR TEST
N/A N/A
HEAD DETAIL
BASE DETAIL
S##.1
PARTITION WIDTH
3-1/8" 4-1/4"
1/2" AIR GAP FOR S2# WALL TYPES
6"
BOTTOM OF
FLOOR/ROOF CONST
FINISHED CEILING HEIGHT
FLOOR/ROOF CONST
FINISHED FLOOR
RE SCHED
5/8" GYPSUM WALL BOARD ROOM SIDE (ABUSE
RESISTANT IN ALL PATIENT ROOMS)
CEILING AS INDICATED ON RCP
CONT METAL RUNNERS TOP AND BOTTOM
SECTION VIEW
METAL FURRING
# SEE SCHEDULE
GYPSUM BOARD (09 29 00) ON ROOM SIDE OF NON-STRUCTURAL METAL FURRING (09 22 16) TO UNDERSIDE OF
FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.
PARTITION TYPE
F0B F1B
STUD SIZE
7/8"
1-1/2"
STC RATING
N/A N/A
FRR TEST
N/A N/A
HEAD DETAIL
BASE DETAIL
F##.X
PARTITION WIDTH
1-1/2" 2-1/8"
EXISTING CONSTRUCTION
BOTTOM OF
FLOOR/ROOF CONST
FINISHED CEILING HEIGHT
FLOOR/ROOF CONST
FINISHED FLOOR
RE SCHED
5/8" GYPSUM WALL BOARD EACH SIDE (ABUSE
RESISTANT IN ALL PATIENT ROOMS)
CONTINUOUS SEALANT AT SOUND / SMOKE WALLS
CEILING AS INDICATED ON RCP
CONT FULL-HEIGHT SOUND BATT INSULATION TO
MEET STC RATING
CONT 8" METAL RUNNERS TOP AND BOTTOM
SECTION VIEW
RE: SCHED
METAL STUDS WITH HORIZONTAL BRACING AS REQ'D
# SEE SCHEDULE
GYPSUM BOARD (09 29 00) ON BOTH SIDES OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO UNDERSIDE OF
FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.
PARTITION TYPE
S8A.A21
STUD SIZE
(2) 3-5/8"
STC RATING
FRR TEST
N/A
HEAD DETAIL
BASE DETAIL
S##.X
PARTITION WIDTH
9-7/8"
SECLUSION ROOM
BOTTOM OF
FLOOR/ROOF CONST
FINISHED CEILING HEIGHT
FLOOR/ROOF CONST
FINISHED FLOOR
5/8" GYPSUM WALL BOARD EACH SIDE (ABUSE
RESISTANT IN ALL PATIENT ROOMS)
CONTINUOUS SEALANT AT SOUND / SMOKE WALLS
CEILING AS INDICATED ON RCP
CONT FULL-HEIGHT SOUND BATT INSULATION TO
MEET STC RATING
CONT METAL RUNNERS TOP AND BOTTOM
SECTION VIEW
RE: SCHED
METAL STUDS WITH HORIZONTAL BRACING AS REQ'D
# SEE SCHEDULE
GYPSUM BOARD (09 29 00) ON BOTH SIDES OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO UNDERSIDE
OF FLOOR CONSTRUCTION OR ROOF CONSTRUCTION.
PARTITION TYPE
S3A.21
S3A.A21 S6A.A21
STUD SIZE
3-5/8" 3-5/8"
6"
STC RATING
N/A
FRR TEST
N/A N/A N/A
HEAD DETAIL
BASE DETAIL
S##.X21
PARTITION WIDTH
5-1/2" 5-1/2" 7-7/8"
SECLUSION ROOM
BOTTOM OF
FLOOR/ROOF CONST
FINISHED CEILING HEIGHT
FLOOR/ROOF CONST
FINISHED FLOOR
(2) LAYERS 5/8" GYPSUM WALL BOARD ROOM SIDE
(ABUSE RESISTANT IN ALL PATIENT ROOMS)
CONTINUOUS SEALANT AT SOUND / SMOKE WALLS
CEILING AS INDICATED ON RCP
CONT FULL-HEIGHT SOUND BATT INSULATION TO
MEET STC RATING
CONT METAL RUNNERS TOP AND BOTTOM
SECTION VIEW
METAL STUDS WITH HORIZONTAL BRACING AS REQ'D
2 LAYERS GYPSUM BOARD (09 29 00) ON ROOM SIDE OF NON-STRUCTURAL METAL FRAMING (09 22 16) TO ABOVE
CEILING.
PARTITION TYPE
S2B.2
S3B.A2
STUD SIZE
2-1/2" 3-5/8"
STC RATING
N/A
FRR TEST
N/A N/A
HEAD DETAIL
BASE DETAIL
S##.2
PARTITION WIDTH
3-3/4" 4-7/8"
1/2" AIR GAP FOR H2# WALL TYPES
6"
SECLUSION ROOM
BOTTOM OF
FLOOR/ROOF CONST
FINISHED CEILING HEIGHT
FLOOR/ROOF CONST
FINISHED FLOOR
RE SCHED
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A45
WALL TYPE SCHEDULE RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 44 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
F SRG1
P E
R S
C H
E D
U
LE
CV
SCHED
PER
1'
SRG2A
1'
6" TYP
P E
R S
C H
E D
U
LE
SCHED
PER PER SCHEDULE
2'
0"
S C
H E
D U
LE
P E
R
P E
R S
C H
E D
U
LE
SCHED
PER
6"
F1 F2
P E
R S
C H
E D
U
LE
2"
2"
SIDELITE
2' - 0" 2" 2"
P E
R S
C H
E D
U
LE
2"
2"
F3
DOUBLE EGRESS
PER SCH2"
SCHED
PER 2"
P E
R S
C H
E D
U
LE
2"
2" PER SCHEDULE 2"
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A46
DOOR SCHEDULES & DETAILS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 45 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
1/4" = 1'-0"
DOOR PANEL TYPE LEGEND
1/4" = 1'-0"
DOOR FRAME TYPE LEGEND
DOOR SCHEDULE - 9TH FLOOR
NUMBER ROOM NAME
DOOR FRAME
RATING
DETAIL
COMMENTS
SIZE
TYPE
LEAF
NUMBER
LEAF 1
SIZE
LEAF 2
SIZE MATERIAL FINISH TYPE MATERIAL FINISH DOOR HEAD DOOR JAMB
C9-00 COURTYARD 84" x 84" SRG2A 2 3' - 6" 3' - 6" ALUM/GL ANOD ALUM ANOD -
C9-01 EAST SUNROOM 72" x 84" SRG2A 2 3' - 0" 3' - 0" ALUM/GL ANOD F1 HM PNT -
C9-02 HAC 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-03 GROUP COUNSELING ROOM 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-04 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-04A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-05 TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-06 MECHANICAL 42" x 84" F 1 3' - 6" WD STN F1 HM PNT 45 MIN
C9-06A ELEC 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-07 OFFICE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-08 MEN'S BARIATRIC 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -
C9-08A TOILET 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -
C9-10 LAUNDRY 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-11 QUIET ROOM 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-11A QUIET ROOM 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-12 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-12A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-14 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-14A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-15 MEN'S BARIATRIC 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -
C9-15A TOILET 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -
C9-16 DINING/ ACTIVITIES 42" x 84" SRG2A 1 3' - 6" ALUM/GL ANOD ALUM ANOD -
C9-16A DINING/ ACTIVITIES 42" x 84" SRG2A 1 3' - 6" ALUM/GL ANOD ALUM ANOD -
C9-16B DINING/ ACTIVITIES 36" x 48" CV 1 3' - 0" MTL PNT MTL PNT -
C9-17 GROUP THERAPY 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-18 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-18A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-20 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-20A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-21 SALLY PORT 72" x 84" F 2 3' - 0" 3' - 0" WD STN F1 HM STN -
C9-22 SERVING KITCHEN 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-23 ELEVATOR LOBBY 72" x 84" F 2 3' - 0" 3' - 0" WD STN F1 HM STN -
C9-24 MEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-24A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-25 ANTE ROOM 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-25A TOILET 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-25B SECLUSION ROOM 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-27 NURSE'S STATION 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-28 SALLY PORT 42" x 84" SRG2A 1 3' - 6" ALUM/GL STN F1 HM PNT -
C9-29 INTERVIEW 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-30 ELEVATOR LOBBY 42" x 84" SRG2A 1 3' - 6" ALUM/GL STN F1 HM PNT -
C9-31 TELECOM ROOM 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-32 MECHANICAL 36" x 84" F 1 3' - 0" WD STN F1 HM PNT 90 MIN
C9-33 STAFF TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-35 NURSE'S LOUNGE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-35B CLOSET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-36 MECH 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-37 TEAMING/ COUNSELING 42" x 84" SRG2A 1 3' - 6" ALUM/GL ANOD ALUM ANOD -
C9-38 EXAM/ INTAKE 42" x 84" SRG2A 1 3' - 6" ALUM/GL ANOD ALUM ANOD -
C9-39 HEAD NURSE OFFICE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-40 MED 36" x 84" F 1 3' - 0" WD STN F1 HM PNT 45 MIN
C9-41 WOMEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-41A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-42 STAFF TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-43 WOMEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-43A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-44 WOMEN'S 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-44A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-45 PATIENT STORAGE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-46 LINEN 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-47 OFFICE/ GROUP ROOM 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-47A STORAGE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-49 WOMEN'S BARIATRIC 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -
C9-49A TOILET 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-50 MEETING 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-51 HAC 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-52 SALLY PORT 42" x 84" SRG2A 1 3' - 6" ALUM/GL STN F1 HM PNT -
C9-54 ELEVATOR LOBBY 42" x 84" SRG2A 1 3' - 6" ALUM/GL STN F1 HM PNT -
C9-55 MECHANICAL 36" x 84" F 1 3' - 0" WD STN F1 HM PNT 45 MIN
C9-56 CLEAN STORAGE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT 45 MIN
C9-57 HAC 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-59 PREFUNCTION/ COLLABORATION 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-60 CONFERENCE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-64 NURSE'S STATION 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-65 MED 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-66 GERIATRIC 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-66A TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-67 BARIATRIC GERIATRIC 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -
C9-67A TOILET 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -
C9-68 BARIATRIC GERIATRIC 48" x 84" F 1 4' - 0" WD STN F1 HM PNT -
C9-68A TOILET 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-69 OFFICE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-70 CLEAN UTILITY 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-71 GROUP THERAPY 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-72 DAY/TV 72" x 84" SRG2A 2 3' - 0" 3' - 0" ALUM/GL STN F1 HM PNT -
C9-C01 CORRIDOR 90" x 84" SRG2A 2 3' - 9" 3' - 9" ALUM/GL ANOD F3 HM PNT -
C9-C02 CORRIDOR 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
C9-C03 CORRIDOR 90" x 84" SRG2A 2 3' - 9" 3' - 9" ALUM/GL ANOD F1 HM PNT -
C9-C04 CORRIDOR 42" x 84" SRG2A 1 3' - 6" ALUM/GL STN F1 HM PNT -
C9-C05 CORRIDOR 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-C06 CORRIDOR 90" x 84" SRG2A 2 3' - 9" 3' - 9" ALUM/GL ANOD F3 HM PNT -
C9-C07 CORRIDOR 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
C9-C08 CORRIDOR 90" x 84" SRG2A 2 3' - 9" 3' - 9" ALUM/GL ANOD F3 HM PNT -
C9-C09 CORRIDOR 84" x 84" SRG2A 2 3' - 6" 3' - 6" ALUM/GL ANOD F1 HM PNT -
DOOR SCHEDULE - WAREHOUSE
NUMBER ROOM NAME
DOOR FRAME
RATING
DETAIL
COMMENTS
SIZE
TYPE
LEAF
NUMBER
LEAF 1
SIZE
LEAF 2
SIZE MATERIAL FINISH TYPE MATERIAL FINISH DOOR HEAD DOOR JAMB
L1-00A STORAGE 60" x 80" F 2 3' - 0" 2' - 0" HM PNT F1 HM PNT -
L1-00B ELEC 36" x 80" F 1 3' - 0" HM PNT F1 HM PNT -
L1-00C ELEC 36" x 80" F 1 3' - 0" HM PNT F1 HM PNT -
L1-00D ELEC 36" x 80" F 1 3' - 0" HM PNT F1 HM PNT -
L1-00E TELECOM ROOM 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
L1-00G TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
L1-01 STORAGE 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
L1-02 OPEN OFFICE 42" x 84" F 1 3' - 6" WD STN F1 HM PNT -
L1-02A CLOSET 48" x 80" F 2 2' - 0" 2' - 0" WD STN F1 HM PNT -
L1-03 OPEN OFFICE 36" x 84" SRG2A 1 3' - 0" ALUM/GL ANOD ALUM ANOD -
L1-05 TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
L1-06 TOILET 36" x 84" F 1 3' - 0" WD STN F1 HM PNT -
L1-07 OFFICE 36" x 84" SRG1 1 3' - 0" WD/GL STN F2 HM PNT -
L1-08 OFFICE 36" x 84" SRG1 1 3' - 0" WD/GL STN F2 HM PNT -
L1-09 OFFICE 36" x 84" SRG1 1 3' - 0" WD/GL STN F2 HM PNT -
L1-10 OFFICE 36" x 84" SRG1 1 3' - 0" WD/GL STN F2 HM PNT -
L1-11 CONFERENCE 36" x 84" SRG1 1 3' - 0" WD/GL STN F2 HM PNT -
L1-12 MECH 60" x 80" F 2 2' - 6" 2' - 6" WD STN F1 HM PNT -
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
R O
9'
8"
5'
0"
1'
RO
8' - 9 1/2"
EQ EQ
4 8
1/
2"
B
5'
0"
1'
R O
9'
8"
EQ EQRO
9' - 0"
8 4
1/
2"
R O
9'
8"
5'
0"
1'
EQ EQ
RO
8' - 8 1/2"
C
8 6
1/
2"
1'
5'
0"
8"
R O
9'
3' - 10 3/4" EQ 3' - 10 3/4"
RO
11' - 8 3/8"
D
6 8 6
1/
2"
1'
5'
0"
8"
R O
9'
EQ EQ
RO
7' - 5 1/2"
E
8 8
1/
2"
8"
R O
9'
1'
5'
0"
EQ EQ EQ
RO
12' - 2 1/8"
F
6 8 6
1/
2"
S1
26' - 6"
SCHEDULE
PER DOOR1' - 8"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"
SCHEDULE
PER DOOR
7'
2'
/2
4"
S2
7'
2'
31' - 10 3/4"
6' - 4" 2' - 4 1/2" 11"
SCHEDULE
PER DOOR 2' - 5 3/4"
SCHEDULE
PER DOOR 11" 2' - 4 1/2" 6' - 4" 3' - 2"
1 11
ALIGN WITH CENTER OF
PARTITION BEYOND
S3
3'
4'
EQ EQ
6' - 6"
3'
4'
4' - 0"
S4
/8
V
IF
P E
R D
O O
R S
C H
E D
U
LE
G
V
IF
4'
/2
8' - 6"
17' - 0" VIF
V
IF
8'
/8
2' - 6"
SCHEDULE
PER DOOR
EQ EQ
3'
R O
7'
/8
5'
/4
RO
8' - 0"
EQ EQ
H
2 2
S2.1
3' - 0"
7'
2'
4"
4 4 4 4 4 4 4
5555555
7'
/2
V
IF
V
IF
2'
18' - 11 1/4" VIF
2' - 3 1/2" 3' - 7 3/4" 2' - 10" 1' - 10" 1' - 10" 3' - 9"
1B
FOR TYPE 1B.1, PANELS
TO BE LOUVERS PER
MECHANICAL DRAWINGS
5'
/8
8'
/8
V
IF
V
IF
2'
/8
3' - 8" 2' - 10" 1' - 10" 1' - 10" 3' - 9"
16' - 8" VIF
5" 5"
5"
444444
5 5 5 5 5
1C
5'
V
IF
2'
V
IF
7'
/2
5' - 1"
7' - 8" VIF
5"
5" 5"
1D.1
4 4
V
IF
2'
M A
T C
H A
D
JA
C E
N T
6'
/4
V
IF
8' - 6" VIF
EQ EQ
A D
JA
C
E N
T
M A
T C
H
J
44 4 4
3' - 4" 3' - 9" 3' - 9" 3' - 9" EQ EQ 3' - 9" 3' - 9" 3' - 9" 3' - 10"
PER DOOR SCHEDULE
36' - 10 1/2"
4'
/8
3'
7/ 8"
1/
2"
P E
R D
O O
R S
C H
E D
U
LE
6 6 6 6
6666666666
6 6 6 6
K
A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT
ARE APPLICABLE.
B. EXTERIOR WINDOW PROFILES FOR SOUTH AND WEST ELEVATIONS ARE
REPRESENTATIVE OF INFORMATION FROM DRAWINGS PROVIDED TO
VALHALLA FROM VHA COR ON 02/10/2020 FROM VHA PROJECT #693-13-111.
WINDOW SIZES HAVE BEEN MODIFIED TO MATCH EXISTING OPENINGS AS
UNDERSTOOD BY VALHALLA AND ARE TO BE VERIFIED IN FIELD.
4'
3'
8' - 0"
EQ 3' - 4" EQ
11 1
S5
8 8
6 6
B1
RO
9' - 0"
EQ EQ
R O
9'
8"
5'
0"
1'
1/
2"
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
:0
1:
A M
01-A47
WINDOW FRAME TYPES RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 46 of 53 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
GLAZING TYPE SCHEDULE
TYPE IMAGE DESCRIPTION
1 3/8" POLYCARBONATE, CLEAR
2 DOUBLE PANED, LOW-E, ARGON FILLED GLAZING, CLEAR
3 7/16" LAMINATED SPANDREL PANEL
DOUBLE PANED, LOW-E, ARGON FILLED GLAZING WITH 3/8"
POLYCARBONATE ON INTERIOR, CLEAR
INSULATED SPANDREL GLAZING UNIT, DOUBLE PANED, ARGON
FILLED
DOUBLE PANED, LOW-E, ARGON FILLED GLAZING WITH 3/8"
POLYCARBONATE BOTH PANES, CLEAR
3/8" POLYCARBONATE, BOD: LUMICOR LUMIFORM NATURAL -
COASTAL
OPERABLE PANE, GLAZING TYPE TO MATCH REST OF SYSTEM,
BOD: KAWNEER GLASSVENT WINDOWS FOR CURTAIN WALL
STOREFRONT/CURTAIN WALL SCHEDULE
TYPE FRAME TYPE HEAD DETAIL JAMB DETAIL SILL DETAIL
1B 2 E3/01-A48 E3/01-A48 SIM F3/01-A48
1B.1 2 E3/01-A48 E3/01-A48 SIM F3/01-A48
1C 2 E3/01-A48 E3/01-A48 SIM F3/01-A48
1D.1 2 E3/01-A48 E3/01-A48 SIM F3/01-A48
A 1 C5/01-A44 RE: 01-A41 RE: 01-A43
B 1 C5/01-A44 RE: 01-A41 RE: 01-A43
B1 1 F5/01-A44 RE: 01-A41 RE: 01-A43
C 1 <varies> <varies> <varies>
D 1 C1/01-A44 RE: 01-A41 RE: 01-A43
E 1 C1/01-A44 RE: 01-A41 RE: 01-A43
F 1 C1/01-A44 RE: 01-A41 RE: 01-A43
G 1 E7/01-A48 E5/01-A48 F5 & F7/01-A48
H 1 E7/01-A48 E5/01-A48 F5 & F7/01-A48
J 4
K 1 F1/01-A44 RE: 01-A41
S1 3 E1/01-A48 D7 & C7/01-A42 F1/01-A48
S2 3 E1/01-A48 C1/01-A48 F1/01-A48
S2.1 3 E1/01-A48 C1/01-A48 F1/01-A48
S3 3 C1/01-A48 C1/01-A48 C1/01-A48
S4 3 C1/01-A48 C1/01-A48 C1/01-A48
S5 3 C1/01-A48 C1/01-A48 C1/01-A48
STOREFRONT/CURTAIN WALL FRAME SCHEDULE
FRAME TYPE DESCRIPTION
1 BOD: KAWNEER 1600 WALL SYSTEM 1, 7 1/"2 D x 2 1/2" W. ANODIZED
2 MATCH MANUFACTURER, PRODUCT LINE, AND FINISH OF PROJECT
NO 693-13-111 - REPLACE EXTERIOR WINDOWS.
3 BOD: KAWNEER TRIFAB 400, 4" D x 1 3/4" W. ANODIZED
4 BOD: MATCH EXISTING NORTH WINDOW FRAMES
9TH FLOOR
92' - 3 3/4"
9TH FLOOR
92' - 3 3/4"
BASEMENT
-14' - 0"
9TH FLOOR
92' - 3 3/4"
9TH FLOOR
92' - 3 3/4"
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
084113-B
088000-A
079200-C
079200-A
084113-B
079200-C
079200-A
092900-A
092216-A
042000-E
088000-A
A. REFER TO SHEET 01-I3 AND 01-A1 FOR ADDITIONAL GENERAL NOTES THAT
ARE APPLICABLE.
B. EXTERIOR WINDOW PROFILES FOR…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .