07 - Drawings General V2.pdf
PDF 5 MB Posted
- Attached to
- Y1DA--9th Floor MH Renovation WBVAMC
- Solicitation number
- 36C24425B0018
About this file
This document is a comprehensive set of architectural and engineering drawings for the Expand Mental Health Clinic project at the Wilkes-Barre VA Medical Center located in Wilkes-Barre, Pennsylvania. The 12-page drawing set, dated December 15, 2023, includes detailed plans for a renovation and expansion project spanning ground, first, and second floors, with drawings covering architectural, structural, mechanical, electrical, plumbing, fire suppression, technology, and fire alarm systems.
The project involves renovating 12,938 square feet of existing space and constructing a 3,726 square foot addition for a new Mental Health Outpatient Department, with a phased construction approach. Phase 1 includes building a new second-floor Police Suite and AHU enclosure, constructing a new mental health addition shell, and renovating stair exits. Phase 2 involves gutting and renovating the existing first-floor Mental Health and Police Suite spaces, including demolishing and reconnecting exterior walls. The project is fully sprinklered and designed to comply with VA construction standards, with a total project budget estimated between $10-20 million and set aside specifically for Service-Disabled Veteran-Owned Small Businesses (SDVOSB).
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALL SECTION
SYMBOL
INTERIOR ELEVATION
SYMBOL
NEW COLUMN GRID
ELEVATION SYMBOL
REVISION NOTE
ENLARGED DETAIL
CALLOUT
ROOM DESIGNATION
SYMBOL
BREAK LINE
ROOF SLOPE
DIRECTION SYMBOL
DETAIL #
PAGE #
DETAIL #
PAGE #
GRAPHIC SCALE AND
NORTH ARROW
A8.1
EXTERIOR ELEVATION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
A8.1
BUILDING SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
DETAIL SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
XX.X
ELEVATION
0'-0"
ROOM
NAME
101A
NORTH
0 1 2
EXISTING ROOM
DESIGNATION SYMBOL
ROOM
NAME
101A
# DEDUCT ALTERNATE -
SEE SHEET G-008
EXISTING COLUMN GRIDXX.X
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
PROJECT IMAGE
LOCATION MAP
/1 /2
:4
:2
P M
C U s e rs
\g s c o tt \D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h g s c o tt a c g -p a .c o m
.r v t
G-001
COVER
1 12GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 DECEMBER 15, 2023
100% CONSTRUCTION DOCUMENTS
693-35220-083
EXPAND MENTAL HEALTH CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711
VA PROJECT #: 693-352
WVS
DRAWING LIST
GENERAL
G-001 COVER 1 12
G-002 ACM FLOOR PLANS 2 12
G-003 CONSTRUCTION LOGISTICS PLAN 3 12
G-004 CODE INFORMATION 4 12
G-005 GROUND FLOOR LIFE SAFETY PLAN 5 12
G-006 FIRST FLOOR LIFE SAFETY PLAN 6 12
G-007 SECOND FLOOR LIFE SAFETY PLAN 7 12
G-008 PHASING PLANS, DEDUCTIVE ALTERNATES AND NOTES 8 12
G-009 ICRA INFORMATION AND DETAILS 9 12
G-010 PHASE 1 CONSTRUCTION ICRA PLANS 10 12
G-011 PHASE 2 CONSTRUCTION ICRA PLANS 11 12
G-012 PHASE 2 CONSTRUCTION ICRA ENLARGED PLANS 12 12
CIVIL
CD101 DEMOLITION PLAN 1 3
CS101 SITE, PAVING, GRADING, & UTILITIES PLAN 2 3
CS501 CIVIL DETAILS 3 3
LANDSCAPE
LP101 LANDSCAPE PLAN 1 2
LP501 LANDSCAPE DETAILS 2 2
STRUCTURAL
S-001 GENERAL NOTES 1 13
S-002 WIND C&C 2 13
S-003 LOADING DIAGRAM 3 13
S-101 FOUNDATION PLAN - AREA A 4 13
S-102 ROOF FRAMING PLAN - AREA A 5 13
S-103 WALKWAY ENCLOSURE FRAMING PLAN - AREA A 6 13
S-104 AHU ENCLOSURE FRAMING PLAN - AREA B 7 13
S-105 OPERABLE FRAMING - AREA B 8 13
S-301 FOUNDATION DETAILS 9 13
S-401 MASONRY DETAILS 10 13
S-501 STEEL FRAMING DETAILS 11 13
S-502 STEEL FRAMING ELEVATIONS 12 13
S-503 STEEL FRAMING ELEVATIONS 13 13
ARCHITECTURAL
A-001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 50
AD100 GROUND FLOOR DEMOLITION PLAN AND REFERENCE PHOTOS 2 50
AD100A GROUND FLOOR DEMOLITION PLAN - AREA A 3 50
AD100B GROUND FLOOR DEMOLITION PLAN - AREA B 4 50
AD101 FIRST FLOOR DEMOLITION PLAN AND REFERENCE PHOTOS 5 50
AD101A FIRST FLOOR DEMOLITION PLAN - AREA A 6 50
AD101B FIRST FLOOR DEMOLITION PLAN - AREA B 7 50
AD102 SECOND FLOOR DEMOLITION PLAN AND REFERENCE PHOTOS 8 50
AD102A SECOND FLOOR DEMOLITION PLAN AND SECTIONS- AREA A 9 50
AD102B SECOND FLOOR DEMOLITION PLAN AND SECTIONS - AREA B 10 50
A-100 GROUND FLOOR PLANS 11 50
A-101 FIRST FLOOR PLAN 12 50
A-101A FIRST FLOOR PLAN - AREA A 13 50
A-101A.1 FIRST FLOOR DIMENSION PLAN - AREA A 14 50
A-101B FIRST FLOOR PLAN - AREA B 15 50
A-101B.1 FIRST FLOOR DIMENSION PLAN - AREA B 16 50
A-102 SECOND FLOOR / ROOF / PENTHOUSE PLAN 17 50
A-102A SECOND FLOOR / ROOF PLANS - AREA A 18 50
A-102B SECOND FLOOR AND PENTHOUSE ROOF PLANS - AREA B 19 50
A-111 FIRST FLOOR REFLECTED CEILING PLAN 20 50
A-111A FIRST FLOOR REFLECTED CEILING PLAN - AREA A 21 50
A-111B FIRST FLOOR REFLECTED CEILING PLAN - AREA B 22 50
A-112 SECOND FLOOR REFLECTED CEILING PLAN 23 50
A-112A SECOND FLOOR REFLECTED CEILING PLAN - AREA A 24 50
A-112B SECOND FLOOR REFLECTED CEILING PLAN - AREA B 25 50
A-201 EXTERIOR ELEVATIONS 26 50
A-202 EXTERIOR ELEVATIONS 27 50
A-203 EXTERIOR ELEVATIONS 28 50
A-204 EXTERIOR ELEVATIONS 29 50
A-301 BUILDING SECTIONS AT MENTAL HEALTH ADDITION 30 50
A-302 BUILDING SECTIONS AT MENTAL HEALTH ADDITION 31 50
A-303 BUILDING SECTIONS AT AHU ENCLOSURE 32 50
A-311 WALL SECTIONS 33 50
A-312 WALL SECTIONS 34 50
A-313 WALL SECTIONS 35 50
A-314 WALL SECTIONS 36 50
A-315 WALL SECTIONS 37 50
A-316 WALL SECTIONS 38 50
A-318 WALL SECTIONS 39 50
A-317 WALL SECTIONS AND DETAILS AND AHU ENCLOSURE 40 50
A-401 ENLARGED PLANS 41 50
A-402 ENLARGED PLANS 42 50
A-501 PARTITION TYPES 43 50
A-502 COLUMN PLAN DETAILS 44 50
A-503 PLAN DETAILS 45 50
A-504 SECTION DETAILS 46 50
A-506 MISCELLANEOUS DETAILS 47 50
A-601 DOOR SCHEDULE, ELEVATIONS AND DETAILS 48 50
A-602 WINDOW SCHEDULE, ELEVATIONS AND DETAILS 49 50
A-901 3D VIEWS 50 50
DRAWING LIST
INTERIORS
I-001 ROOM FINISH SCHEDULE, GENERAL NOTES AND ABBREVIATIONS 1 37
I-101A FIRST FLOOR FINISH AND WALL PROTECTION PLAN - AREA A 2 37
I-101B FIRST FLOOR FINISH AND WALL PROTECTION PLAN - AREA B 3 37
I-102 SECOND FLOOR FINISH AND WALL PROTECTION PLANS- AREAS A AND B 4 37
I-121A FIRST FLOOR PATTERN PLAN - AREA A 5 37
I-121B FIRST FLOOR PATTERN PLAN - AREA B 6 37
I-122 SECOND FLOOR PATTERN PLANS A AND B 7 37
I-141A FIRST FLOOR SIGNAGE PLAN - AREA A 8 37
I-141B FIRST FLOOR SIGNAGE PLAN - AREA B 9 37
I-142 SECOND FLOOR SIGNAGE PLANS AREAS A AND B 10 37
I-201 CASEWORK AND MILLWORK ELEVATIONS 11 37
I-202 CASEWORK AND MILLWORK PLANS AND ELEVATIONS 12 37
I-203 CASEWORK DETAILS 13 37
I-401 INTERIOR ELEVATIONS - WALL PROTECTION 14 37
I-402 INTERIOR ELEVATIONS-WALL PROTECTION 15 37
I-403 INTERIOR ELEVATIONS - WALL PROTECTION 16 37
I-404 INTERIOR ELEVATIONS AND SECTIONS - WALL PROTECTION 17 37
I-405 INTERIOR ELEVATIONS - EQUIPMENT 18 37
I-406 INTERIOR ELEVATIONS - EQUIPMENT 19 37
I-421A FIRST FLOOR EQUIPMENT PLAN - AREA A 20 37
I-421B FIRST FLOOR EQUIPMENT PLAN - AREA B 21 37
I-422 SECOND FLOOR EQUIPMENT PLAN- AREAS A AND B 22 37
I-423 ENLARGED FIRST FLOOR EQUIPMENT PLAN - AREA A.1 23 37
I-424 ENLARGED FIRST FLOOR EQUIPMENT PLAN - AREAS A.2 AND B 24 37
I-425 ENLARGED FIRST FLOOR EQUIPMENT PLAN - AREA A.3 25 37
I-426 ENLARGED SECOND FLOOR- POLICE SECURITY - AREA A 26 37
I-427 ENLARGED EQUIPMENT PLANS 27 37
I-428 ENLARGED EQUIPMENT PLANS 28 37
I-429 ENLARGED EQUIPMENT PLANS 29 37
I-430 ENLARGED EQUIPMENT PLANS 30 37
I-431 ENLARGED TOILET PLANS AND ELEVATIONS 31 37
I-432 ENLARGED TOILET PLANS AND ELEVATIONS 32 37
I-433 ENLARGED TOILET PLANS AND ELEVATIONS 33 37
I-434 ENLARGED TOILET PLANS AND ELEVATIONS 34 37
I-501 INTERIOR DETAILS 35 37
I-601 EQUIPMENT SCHEDULE 36 37
I-602 EQUIPMENT SCHEDULE 37 37
FIRE SUPPRESSION
FX001 FIRE SUPPRESSION GENERAL INFORMATION 1 7
FK101A FIRST FLOOR AND CRAWL SPACE FIRE SUPPRESSION DEMOLITION PLAN - AREA A 2 7
FK101B FIRST FLOOR FIRE SUPPRESSION DEMOLITION PLAN - AREA B 3 7
FK102AB SECOND FLOOR FIRE SUPPRESSION DEMOLITION PLAN - AREA A AND B 4 7
FX101A FIRST FLOOR FIRE SUPPRESSION PLAN AND CRAWL SPACE FIRE SUPPRESSION PLAN - AREA A 5 7
FX101B FIRST FLOOR FIRE SUPPRESSION PLAN - AREA B 6 7
FX102AB SECOND FLOOR FIRE SUPPRESSION PLAN - AREA A AND B 7 7
PLUMBING
P-001 PLUMBING GENERAL INFORMATION 1 22
PD100A GROUND FLOOR PLUMBING DEMOLITION PLAN - AREA A 2 22
PD100B GROUND FLOOR PLUMBING DEMOLITION PLAN - AREA B 3 22
PD101A FIRST FLOOR DOMESTIC WATER DEMOLITION PLAN - AREA A 4 22
PD101B FIRST FLOOR DOMESTIC WATER DEMOLITION PLAN - AREA B 5 22
PD102AB SECOND FLOOR DOMESTIC WATER DEMOLITION - AREAS A AND B 6 22
PD111A FIRST FLOOR PLUMBING DEMOLITION PLAN - AREA A 7 22
PD111B FIRST FLOOR PLUMBING DEMOLITION PLAN - AREA B 8 22
PD112AB SECOND FLOOR SANITARY AND VENT DEMOLITION PLAN - AREAS A AND B 9 22
P-100A GROUND FLOOR PLUMBING PLAN - AREA A 10 22
P-100B GROUND FLOOR PLUMBING PLAN - AREA B 11 22
PP101A FIRST FLOOR DOMESTIC WATER PLAN - AREA A 12 22
PP101B FIRST FLOOR DOMESTIC WATER PLAN - AREA B, AND ENLARGED DOMESTIC WATER PLAN 13 22
PP102AB SECOND FLOOR DOMESTIC WATER PLAN - AREAS A AND B 14 22
PW101A FIRST FLOOR DRAIN, WASTE, AND VENT PLAN - AREA A 15 22
PW101B FIRST FLOOR DRAIN, WASTE, AND VENT PLAN - AREA B, AND ENLARGED DRAIN, WASTE, AND
VENT PLAN
16 22
PW102AB SECOND FLOOR DRAIN, WASTE, AND VENT PLAN - AREAS A AND B 17 22
PW103B ROOF DRAIN PLAN - AHU ENCLOSURE 18 22
P-501 PLUMBING DETAILS 19 22
P-601 PLUMBING SCHEDULES 20 22
P-901 DRAIN, WASTE, AND VENT PIPE RISERS - AREAS A AND B 21 22
P-902 DOMESTIC PIPE RISERS - AREAS A AND B 22 22
MECHANICAL
M-001 MECHANICAL GENERAL INFORMATION 1 16
MD101A FIRST FLOOR MECHANICAL DEMOLITION PLAN - AREA A 2 16
MD101B FIRST FLOOR MECHANICAL DEMOLITION PLAN - AREA B 3 16
MD102 SECOND FLOOR MECHANICAL DEMOLITION PLAN 4 16
MH101A FIRST FLOOR HVAC PLAN - AREA A AND SECOND FLOOR EXIT CORRIDOR 5 16
MH101B FIRST FLOOR HVAC PLAN - AREA B 6 16
MH102 SECOND FLOOR HVAC PLAN 7 16
MP101A FIRST FLOOR MECHANICAL PIPING PLAN - AREA A 8 16
MP101B FIRST FLOOR MECHANICAL PIPING PLAN - AREA B 9 16
MP102 SECOND FLOOR MECHANICAL PIPING PLAN 10 16
M-401 ENLARGED MECHANICAL PLANS 11 16
M-501 MECHANICAL DETAILS 12 16
M-502 MECHANICAL DETAILS 13 16
M-503 MECHANICAL CONTROLS 14 16
M-504 MECHANICAL CONTROLS 15 16
M-601 MECHANICAL SCHEDULES 16 16
DRAWING LIST
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 26
ED101A FIRST FLOOR ELECTRICAL DEMOLITION PLAN - AREA A 2 26
ED101B FIRST FLOOR ELECTRICAL DEMOLITION PLAN - AREA B 3 26
ED102A SECOND FLOOR ELECTRICAL DEMOLITION PLAN - AREA A 4 26
ED102B SECOND FLOOR ELECTRICAL DEMOLITION PLAN - AREA B 5 26
ED111A FIRST FLOOR ELECTRICAL CEILING DEMOLITION PLAN - AREA A 6 26
ED111B FIRST FLOOR ELECTRICAL CEILING DEMOLITION PLAN - AREA B 7 26
ED112A SECOND FLOOR ELECTRICAL CEILING DEMOLITION PLAN - AREA A 8 26
ED112B SECOND FLOOR ELECTRICAL CEILING DEMOLITION PLAN - AREA B 9 26
EP101A FIRST FLOOR POWER PLAN - AREA A 10 26
EP101B FIRST FLOOR POWER PLAN - AREA B 11 26
EP102A SECOND FLOOR POWER PLAN - AREA A 12 26
EP102B SECOND FLOOR POWER PLAN - AREA B 13 26
EM101A FIRST FLOOR MECHANICAL POWER PLAN - AREA A 14 26
EM101B FIRST FLOOR MECHANICAL POWER PLAN - AREA B 15 26
EM102A SECOND FLOOR MECHANICAL POWER PLAN - AREA A 16 26
EM102B SECOND FLOOR MECHANICAL POWER PLAN - AREA B 17 26
EL111A FIRST FLOOR LIGHTING PLAN - AREA A 18 26
EL111B FIRST FLOOR LIGHTING PLAN - AREA B 19 26
EL112A SECOND AND GROUND FLOOR LIGHTING PLANS - AREA A 20 26
EL112B SECOND FLOOR LIGHTING PLAN - AREA B 21 26
E-501 ELECTRICAL DETAILS 22 26
E-601 ELECTRICAL SCHEDULES 23 26
E-602 ELECTRICAL SCHEDULES 24 26
E-603 ELECTRICAL SCHEDULES 25 26
E-604 ELECTRICAL SCHEDULES 26 26
TECHNOLOGY
T-001 TECHNOLOGY GENERAL NOTES, SYMBOL LEGEND, AND ABBREVIATIONS 1 8
T-101A FIRST FLOOR TECHNOLOGY PLAN - AREA A 2 8
T-101B FIRST FLOOR TECHNOLOGY PLAN - AREA B 3 8
T-102A SECOND FLOOR TECHNOLOGY PLAN - AREA A 4 8
T-102B SECOND FLOOR TECHNOLOGY PLAN - AREA B 5 8
T-401 TECHNOLOGY ENLARGEMENTS 6 8
T-501 TECHNOLOGY DETAILS 7 8
T-601 TECHNOLOGY RISERS 8 8
FIRE ALARM
FA001 FIRE ALARM GENERAL NOTES, SYMBOL LEGEND, AND RISER 1 5
FA101A FIRST FLOOR FIRE ALARM PLAN - AREA A 2 5
FA101B FIRST FLOOR FIRE ALARM PLAN - AREA B 3 5
FA102A SECOND FLOOR FIRE ALARM PLAN - AREA A 4 5
FA102B SECOND FLOOR FIRE ALARM PLAN - AREA B 5 5
GENERAL SYMBOL LEGEND
DocuSign Envelope ID: 3E675697-45AF-4826-B2BA-4DFD242CA0AF
12/15/2023
DN DN
UP
DN
UP
UP
DN
UP
D N
DN
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE SLOPE
SLOPE
SLOPE
S SS S S
S S
S SS S
S
S
S
SS
S S
S S
S S
S S
S
S
S
S
S
S SS
S
S SS S
S S
S S
S
S S
S S
S
S SS S
S S
S
S
S
S
S S S
SS
S
DN
S SS
S S
SS SS
S S
S S
S S
SS
S S
S
UP
OFFICE
C1-65
OFFICE
C1-63
TOILET
C1-59
TOILET
C1-58
STORAGE
C1-59
POLICE
INTERVIEW
RM
C1-56D
POLICE
TRAINING/
LOCKER
C1-56D
POLICE
OFFICE
C1-24
BED
STORAGE
C1-23
IT
C1-22D
CONF
ROOM
A1-10
OFFICE
A1-09
OFFICE
A1-09A
EXAM
A1-08
EXAM
A1-11
EXAM
A1-14
EXAM
A1-16
EXAM
A1-07
EXAM
A1-06
EXAM
A1-20
EXAM
A1-15
EXAM
A1-12
EXAM
A1-23
CLEAN
LINEN
A1-02
T L
T
A
-2
A
EXAM
A1-27
ELEC
A1-03
ELEC
A1-30
ELEV
S-1
ELEV
S-2
ELEV
S-3
ELEV
P-3
ELEV
P-2
ELEV
P-1
CORR
A1-01
ATRIUM
CORR
A1-04
CORR
A1-13
STAIR
STAIR
3VOLUNTARY
C1-77
STOR
C1-78A
ELEC
C1-76
MECH
C1-78
MECH
ELEV
ELEV
ELEV
ELEV
ELEV
ELEV
IT
C1-21B
IT
C1-21C
MECHANICAL
C1-22C
IT
C1-22E
MECH
C1-22G
MECHANICAL
BASEMENT
ROOF
CRAWL
SPACE
CRAWL
SPACE
MECHANICAL
COURTYARD
CRAWL
SPACE
BASEMENT ROOF
STAIR
ELEV
LOBBY
A1-31A
SOILED
LINEN
A1-29
BASEMENT
ROOF
BASEMENT
ROOF
MECH ELEC
ELEC ELEC
A1-05
A1-28
OFFICE
C1-74
OFFICE
C1-74A
OFFICE
C1-73
OFFICE
C1-72
OFFICE
C1-71
OFFICE
C1-70A
OFFICE
C1-70
OFFICE
C1-01B
OFFICE
C1-01A
ROI
C1-02
ROI
WAITING
C1-03
OFFICE
C1-03A
C1-01
CORRIDOR
21-13
C1-08
STORAGE
1-A
STORAGE
1-B
STORAGE
2-A
STORAGE
2-B
OFFICE
C1-12
OFFICE
C1-09
OFFICE
C1-11
OFFICE
C1-06
OFFICE
C1-07
TOILET
C1-14
MY
HEALTH
VET
C1-05
OFFICE
C1-68
OFFICE
C1-67
OFFICE
C1-66
21-4
POLICE
STORAGE
C1-27
CORR
C1-18
OFFICE
C1-55
OFFICE
C1-54
POLICE
OFFICE
C1-28
TOILET
C1-32A
EMS
STORAGE
C1-31
TOILET
C1-32B
CORR
C1-34
ELEC
C1-35
MECH
C1-35A
STAIR
C1-28
WAITING
C1-32
CHECK
IN
C1-32C
OFFICE
C1-36A
OFFICE
C1-36
OFFICE
C1-37
OFFICE
C1-38
GROUP
RM
C1-39
CONFERENCE
RM
C1-40
OFFICE
C1-41
OFFICE
C1-42
OFFICE
C1-43
OFFICE
C1-44
OFFICE
C1-45
OFFICE
C1-51
OFFICE
C1-52
OFFICE
C1-53
CORR
C1-18A
CORR
C1-50B
OFFICE
C1-49A
BREAK
RM
C1-49B
TOILET
C1-50A
OFFICE
C1-46
HAC
C1-46A
ELEC
C1-46B
TOILET
C1-49
OFFICE
C1-48B
OFFICE
C1-48A
OFFICE
C1-48
OFFICE
C1-47B
OFFICE
C1-47A MECHANICAL
C1-47
OFFICE
C1-71
OFFICE
C1-70
ROI
C1-02
ROI
WAITING
C1-03
OFFICE
C1-03A
C1-01
CORRIDOR
21-13
CORRIDOR
21-14
C1-08
OFFICE
C1-09
OFFICE
C1-10
TOILET
C1-15
MY
HEALTH
VET
C1-05
OFFICE
C1-68
OFFICE
C1-67
OFFICE
C1-66
CORRIDOR
C1-69
CORRIDOR
C1-18
CORRIDOR
C1-16
MECHANICAL
COURTYARD
CRAWL
SPACE
TR
AB
B A
IT
SERVER
ROOM
C1-85
IT
SERVER
ROOM
C1-88
IT
SERVER
ROOM
C1-89
IT
SERVER
ROOM
C1-90
ELEV
LOBBY
C1-75
C1-08
OFFICE
C1-09
OFFICE
C1-10
IT
SERVER
ROOM
C1-85
TOUCHDOWN
A5-005
EXAM
RM
A2-007
TOILET
A2-009
OFFICE
A2-010
STAFF
TOILET
A2-008
WAITING
RM
A2-003
TOILET
A2-05A
CHECK-IN
A2-004
CLEAN
LINEN
A2-18
SOILED
A2-017
CORRIDOR
A2-013
A2-002
STAIR
CORRIDOR
C2-11
OFFICE
C2-03
MECH
C2-10 ELEC
C2-02
STAIR
CORRIDOR
A2-001
CORRIDOR
C2-32
STORAGE
C2-118
STORAGE
C2-119
STORAGE
C2-120
STORAGE
C2-117
CORRIDOR
C2-116
OFFICE
C2-121
OFFICE
C1-70A
ROOF
U L
T R
A S
O U
N D
W A
IT
IN
G
C
-2
ULTRASOUND
TECHS/FILES
C2-30
CLEAN
HOLDING
C2-31D
CORRIDOR
C2-32
CORRIDOR
C2-32A
FILE
RM
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
224OFFICE
STRESS
LAB
BREAK
RM
PRE-TEST
C2-25
CORRIDOR
C2-26
OFFICE
C2-24D
M E
C H
C
-2
A
E L
E C
C
-2
T O
IL
E
T
C
-2
C O
R R
ID
O
R
TLT
TLT
WAITING
STAIR
S-2
STOR
CG-18C
LOCKER
CG-22
STORAGE
CG-23
STORAGE
CG-25
STORAGE
CG-26
BREAK
RM
CG-28
MECHANICAL
RM
CG-51A
CORRIDOR
EG-48
MECHANICAL
RM
CG-20A
REPRODUCTION
OFFICE
CG-59
REPRODUCTION
OFFICE
CG-58
EMS
STORAGE
CG-57
BREAL
RM
CG-56
TOILET
CG-21
STAIR
CG-18A
CG-18
CG-55
THESE AREAS ARE KNOWN TO
HAVE ASBESTOS CONTAINING
MATERIALS. FOR ALL
CONSTRUCTION DEMOLITION
ACTIVITY, CONTRACTORS TO
TREAT ENTIRE SHADED AREAS
AS ASBESTOS CONTAINMENT
AREAS. CONTRACTOR TO
REFERENCE VA SURVEY 2014 -
VA PROJECT # 10013.00-IN.
ALL WORK IN THE CORRIDORS
NEED TO BE AFTER-HOURS
WITH CLEAN UP AFTER EACH
SHIFT. CORRIDORS TO REMAIN
PUBLIC USE DURING BUSINESS
HOURS.
COORDINATE SEQUENCING
WITH VA COR PRIOR TO ANY
DEMOLITION. SEE SHEET G-008
FOR PROPOSED PHASING.
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1 /2
:4
:4
P M
C U s e rs
\g s c o tt \D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h g s c o tt a c g -p a .c o m
.r v t
G-002
ACM FLOOR PLANS
2 12GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 DECEMBER 15, 2023
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 1/16" = 1'-0"
FIRST FLOOR ACM PLAN
NORTH
0 8 16 32
Scale: 1/16" = 1'-0"
SECOND FLOOR ACM PLAN AREA B
Scale: 1/16" = 1'-0"
SECOND FLOOR ACM PLAN -
AREA A
3 NORTH
0 8 16 32
NORTH
0 8 16 32
Scale: 1/16" = 1'-0"
GROUND FLOOR ACM PLAN
NORTH
0 8 16 32
LEGEND
AB
B A
E A
S T E
N D
B O
U L E
V A
R D
BEAR CREEK BOULEVARD
EAST END BLVD
EAST END BLVD
3 3
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
EXISTING BUILDING ENTRANCE
PROPOSED CRANE LOCATION
EXISTING BUILDING FOOTPRINT
MENTAL HEALTH ADDITION
PROPOSED TEMPORARY
FENCING LOCATION
MATCHLINE
AREA OF WORK
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1 /2
:4
:5
P M
C U s e rs
\g s c o tt \D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h g s c o tt a c g -p a .c o m
.r v t
G-003
CONSTRUCTION LOGISTICS PLAN
3 12GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 DECEMBER 15, 2023
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 1" = 40'-0"
CONSTRUCTION LOGISTICS PLAN
NORTH
0 4020 80
A. LOCATION AND EXTENTS OF STAGING AREA
SHALL BE FULLY COORDINATED WITH THE
VA/COR. THE DESIGNATED ELEVATOR AND
STAIRS TO BE USED BY THE CONTRACTOR
SHALL BE ASSIGNED AND APPROVED BY THE
VA COR.
B. BEFORE PROCEEDING WITH ANY WORK, IT
SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO PROVIDE NECESSARY
SAFEGUARDS TO MAINTAIN ALL PARTS OF
THIS PROJECT UNDER THIS CONTRACT IN A
SAFE CONDITION AT ALL TIMES AND PROTECT
FROM DAMAGE THOSE PORTIONS WHICH ARE
TO REMAIN.
C. CONTRACTOR SHALL REPAIR DAMAGES TO
THE EXISTING PAVED AREAS, CURB,
LANDSCAPE/VEGETATION, ETC. CAUSED BY
DEMOLITION WORK.
D. CONTRACTOR TO VERIFY ALL UNDERGROUND
UTILITIES PRIOR TO CRANE PLACEMENT.
E. CONTRACTOR TO COORDINATE WITH COR
AND DEVELOP A WORK PLAN TO INCLUDE
CONSTRUCTION ROUTE ACCESS, WORKING
HOURS BY PHASE (SEE PHASING PLANS NEXT
SHEET), MATERIALS STORAGE, AND REMOVAL
OF HAZARDOUS MATERIALS.
SITE LEGEND
1 CONTRACTOR RESPONSIBLE TO PROVIDE 2
TEMPORARY TOILETS FOR THE ENTIRE
CONSTRUCTION PERIOD OF NEW ADDITION.
2 PROPOSED CRANE LOCATION. VERIFY ALL
UNDERGROUND UTILITIES AND SOIL BEARING
CAPACITY PRIOR TO CRANE PLACEMENT. ALL
DAMAGED PAVEMENT TO BE RESTORED TO
ORIGINAL CONDITION.
3 EXISTING STAIRS DOWN TO LOWER LOT. ALL
CONTRACTOR PARKING TO BE IN LOWER LOT.
4 PROPOSED DUMPSTER LOCATION.
5 PROPOSED CONSTRUCTION TRAILER LOCATION.
6 CONSTRUCTION ACCESS.
7 DESIGNATED CONTRACTOR PARKING AREA TO BE
COORDINATED WITH COR.
8 PROPOSED CONTRACTOR STAGING AREA.
9 CONSTRUCTION CHAIN LINK FENCE AND GATE.
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF
1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL
AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL"
BUILDING CODES. THE FEDERAL PARTICIPATION IN THE
DEVELOPMENT AND USE OF VOLUNTARY STANDARDS,
OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR
A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON
VOLUNTARY STANDARDS, BOTH DOMESTIC AND
INTERNATIONAL, WHENEVER FEASIBLE, AND TO
PARTICIPATE IN VOLUNTARY STANDARD BODIES.
GENERAL - BASED ON THE VA PG-18-3 DESIGN AND
CONSTRUCTION PROCEDURES, THIS PROJECT HAS BEEN
DESIGNED TO, AND CONSTRUCTION SHALL COMPLY WITH
THE FOLLOWING CODES AND GUIDELINES:
(AS OF EFFECTIVE PROJECT DESIGN CONTRACT DATE,
MAY 04, 2021)
• VA DIRECTIVES, DESIGN MANUALS, MASTER
SPECIFICATIONS, VA NATIONAL CAD STANDARD
APPLICATION GUIDE, AND OTHER GUIDANCE ON THE
TECHNICAL INFORMATION LIBRARY (TIL)
(HTTP://WWW.CFM.VA.GOV/TIL/).
• INTERNATIONAL BUILDING CODE (IBC) 2021 (ONLY WHEN
SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS,
SEE NOTES BELOW)
• NFPA 101 LIFE SAFETY CODE 2021 (SEE NOTES BELOW)
• NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF
NFPA 5000 AND NFPA 900
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION
(OSHA) STANDARDS.
• VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• NATIONAL ELECTRICAL CODE (NEC)
• INTERNATIONAL PLUMBING CODE (IPC) 2021
• SAFETY CODE FOR ELEVATORS AND ESCALATORS,
AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)
A 17.1.
• ASME BOILER AND PRESSURE VESSEL CODE
• ASME CODE FOR PRESSURE PIPING
• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY
STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT,
BARRIER FREE DESIGN STANDARD (PG-18-13)
• BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE, AMERICAN CONCRETE INSTITUTE AND
COMMENTARY (ACI 318)
• MANUAL OF STEEL CONSTRUCTION, LOAD AND
RESISTANCE FACTOR DESIGN SPECIFICATIONS FOR
STRUCTURAL STEEL BUILDINGS, AMERICAN INSTITUTE OF
STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• DOE INTERIM FINAL RULE: ENERGY CONSERVATION
STANDARDS FOR NEW FEDERAL, COMMERCIAL AND
MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND
NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS
433, 434 AND 435.
• FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND
SUSTAINABLE BUILDINGS: MEMORANDUM OF
UNDERSTANDING (MOU)
• THE PROVISIONS FOR CONSTRUCTION AND SAFETY
SIGNS. STATED IN THE GENERAL REQUIREMENTS
SECTION 01010 OF THE VA MASTER CONSTRUCTION
SPECIFICATION.
• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY –
ASHRAE STANDARD 62.1- 2022.
• SAFETY STANDARD FOR REFRIGERATION SYSTEMS –
ASHRAE STANDARD 15 – 2022.
LOCAL CODES: AS AN AGENCY OF THE FEDERAL
GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION
OF CODE ENFORCEMENT PROCEDURES (DRAWING
REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.).
VA MUST FUNCTION AS THE AUTHORITY HAVING
JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY
TO GUARD PUBLIC HEALTH AND SAFETY THROUGH
ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL
AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED
PROJECTS AND GIVEN OPPORTUNITY TO REVIEW
DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR
REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND
FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES
A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT
NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC
STABILITY, SANITATION, ADEQUATE LIGHT AND
VENTILATION, AND ENERGY CONSERVATION. VA
BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101
AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER
TO COMPLY WITH THE ACCREDITATION REQUIREMENTS
OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL
COMPLY WITH THE REQUIREMENTS OF THE LATEST
EDITION OF NFPA 101 AND DOCUMENTS REFERENCED
THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA
101 OR DOCUMENTS REFERENCED THEREIN SHALL
COMPLY WITH THE REQUIREMENTS OF THE LATEST
EDITION OF THE IBC OR AS OTHERWISE ADDRESSED
ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES
THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS
NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101,
THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT
REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY
(THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE
DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED
CODES AND STANDARDS AND VA REQUIREMENTS –
SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS
AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND
STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE
ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT
SHALL BE MADE BY THE AUTHORITY HAVING
JURISDICTION FOR VA TO ENSURE A CONSISTENCY
SYSTEM WIDE.
CODE SUMMARY -
WILKES-BARRE VAMC
FIRST FLOOR OUTPATIENT
METAL HEALTH AREA
OCCUPANCY
PRIMARY OCCUPANCY:
MALE FEMALE MALE FEMALE STD.
PLUMBING FIXTURE REQUIREMENTS
WATER CLOSETS DRINKING FOUNTAINS
USE
LAVATORIES
URINALS
SHOWERS/
TUBS
ACCESS.
OUTPATIENT
MENTAL HEALTH
BUSINESS
MECHANICAL SUMMARY - SEE MECHANICAL DRAWINGS
ELECTRICAL SUMMARY - SEE ELECTRICAL DRAWINGS
STRUCTURAL DESIGN - SEE STRUCTURAL DRAWINGS
AMBULATORY HEALTH CARE
MALE FEMALE MALE FEMALE
REQUIRED EXISTING
WATER CLOSETS
LAVATORY 6 6 8 11
SERVICE SINKS
DRINKING
FOUNTAINS
1 2
1 2
OUTPATIENT MENTAL HEATLH = 19,549 - USE GROUP B - OUTPATIENT 19,549/100 = 195 ADJUSTED 196
98 MEN / 98 WOMEN
SEE SHEET S-001 FOR STRUCTURAL
CODE AND DESIGN CRITERIA
PROVIDED
MALE FEMALE MALE FEMALE
TOTAL
X X
X
X
X X
X
X
CONSTRUCTED:
ADDITION:
ORIGINAL USE(S):
CURRENT USE(S):
PROPOSED USE(S):
NEW CONSTRUCTION ADDITION UPFIT
RECONSTRUCTION ALTERATION REPAIR RENOVATION
SCOPE TYPE:
HEALTHCARE
GROSS BUILDING AREA:
HIGH RISE:
NEW ADDITION BUILDING DATA (NFPA 220):
FIRE DISTRICT:
SPRINKLERS:
MEZZANINE:
ALLOWABLE BUILDING HEIGHT:
CONSTRUCTION TYPE:
STANDPIPES:
IV (2HH)
I (442)
III (211)
II (222)I (332)
III (200)
II (111)
V (111)
NO NFPA 13YES NFPA 13R NFPA 13D
NO CLASSYES
NO YES
FEET # STORIES
NO YES
NO YES CENTRAL REFERENCE SHEET #
NFPA 13 NFPA 13R NFPA 13D
UNLIMITED UNLIMITED
FLOOR EXISTING (SQ FT) NEW (SQ FT) RENOVATED SUB-TOTAL ALLOWABLE
GROUND
TOTAL
ACTUAL BUILDING HEIGHT: FEET # STORIES17 2
1ST FLOOR
2ND FLOOR 91,011
80,210
132,647
303,868
3,697
4,036
15,220
15,513
II (000)
V (000)
(ASSUMED EXISTING TYPE)
(STORIES ABOVE LEVEL OF DISCHARGE PER NFPA 101 4.6.3)
18,917 UNLIMITED
19,549
GROSS BUILDING AREA:
HIGH RISE:
EXISTING BUILDING DATA (NFPA 220):
FIRE DISTRICT:
SPRINKLERS:
MEZZANINE:
ALLOWABLE BUILDING HEIGHT:
CONSTRUCTION TYPE:
STANDPIPES:
IV (2HH)
I (442)
III (211)
II (222)I (332)
III (200)
II (111)
V (111)
NO NFPA 13YES NFPA 13R NFPA 13D
NO CLASSYES
NO YES
FEET # STORIES
NO YES
NO YES CENTRAL REFERENCE SHEET #
NFPA 13 NFPA 13R NFPA 13D
UNLIMITED UNLIMITED
FLOOR EXISTING (SQ FT) NEW (SQ FT) RENOVATED SUB-TOTAL ALLOWABLE
GROUND
TOTAL
ACTUAL BUILDING HEIGHT: FEET # STORIES141 11
1ST FLOOR 64,185
3,726
12,938
II (000)
V (000)
(ASSUMED EXISTING TYPE)
(STORIES ABOVE LEVEL OF DISCHARGE PER NFPA 101 4.6.3)
67,980 UNLIMITED
FIRE PROTECTION REQUIREMENTS *
LIFE SAFETY PLAN SHEET #: G-005, G-006, G-007
HEALTHCARE
HEALTHCARE
2ND FLOOR 64,185 3,726 12,938 67,980 UNLIMITED
UNLIMITED
UNLIMITED
UNLIMITED
CODE SUMMARY -
WILKES-BARRE VAMC SECOND
FLOOR POLICE OFFICE
GROSS BUILDING AREA:
HIGH RISE:
EXISTING BUILDING DATA (NFPA 220):
FIRE DISTRICT:
SPRINKLERS:
MEZZANINE:
ALLOWABLE BUILDING HEIGHT:
CONSTRUCTION TYPE:
STANDPIPES:
OCCUPANCY
EXISTING 2ND FLOOR PRIMARY OCCUPANCY:
FIRE PROTECTION REQUIREMENTS *
PLUMBING FIXTURE REQUIREMENTS
IV (2HH)
I (442)
III (211)
II (222)I (332)
III (200)
II (111)
V (111)
NO NFPA 13YES NFPA 13R NFPA 13D
NO CLASSYES
NO YES
FEET # STORIES
NO YES
NO YES CENTRAL REFERENCE SHEET #
BUSINESS
LIFE SAFETY PLAN SHEET #:
NFPA 13 NFPA 13R NFPA 13D
NEW CONSTRUCTION ADDITION UPFIT
RECONSTRUCTION ALTERATION REPAIR RENOVATION
UNLIMITED UNLIMITED
FLOOR EXISTING (SQ FT) NEW (SQ FT) RENOVATED SUB-TOTAL ALLOWABLE
TOTAL
SCOPE TYPE:
ACTUAL BUILDING HEIGHT: FEET # STORIES141 11
2ND FLOOR 91,011 0
2,890
2,890
II (000)
V (000)
AMBULATORY HEALTH CARE
(ASSUMED EXISTING TYPE)
(STORIES ABOVE LEVEL OF DISCHARGE PER NFPA 101 4.6.3)
2,890
2,890
UNLIMITED
G-007
POLICE SUITE = 2890 - USE GROUP B - POLICE SUITE 2890/100 = 28.9 ADJUSTED 30
15 MEN / 15 WOMEN
MALE FEMALE MALE FEMALE
REQUIRED PROVIDED
WATER CLOSETS
LAVATORY 1 1 1 1
SERVICE SINKS
DRINKING
FOUNTAINS
1 1
1 1
MIXED OCCUPANCY:
NO YES SEPARATION: HR. EXCEPTION:
OCCUPANCY
BLDG AREA PER STORY
(ACTUAL)
3 HEALTHCARE
2 HEALTHCARE
1 BUSINESS
BUILDING AREA
G BUSINESS
0 NFPA CH. 43.7
PRIMARY
SECONDARY BASED
OFF 2017 LSA PRIMARY
SECONDARY BASED
OFF 2017 LSA
MECHANICAL SUMMARY - SEE MECHANICAL DRAWINGS
ELECTRICAL SUMMARY - SEE ELECTRICAL DRAWINGS
STRUCTURAL DESIGN - SEE STRUCTURAL DRAWINGS
SEE SHEET S-001 FOR STRUCTURAL
CODE AND DESIGN CRITERIA
NEW POLICE SUITE OCCUPANCY:
78,355
91,011
80,210
132,6471,328
UNLIMITED91,011
CODE SUMMARY - WILKES-BARRE VAMC
HIGH RISE:
EXISTING BUILDING DATA (NFPA 220):
FIRE DISTRICT:
SPRINKLERS:
MEZZANINE:
ALLOWABLE BUILDING HEIGHT:
CONSTRUCTION TYPE:
STANDPIPES:
OCCUPANCY
IV (2HH)
I (442)
III (211)
II (222)I (332)
III (200)
II (111)
V (111)
NO NFPA 13YES NFPA 13R NFPA 13D
NO CLASSYES
NO YES
FEET # STORIES
NO YES
NO YES CENTRAL REFERENCE SHEET #
NFPA 13 NFPA 13R NFPA 13D
UNLIMITED UNLIMITED
ACTUAL BUILDING HEIGHT: FEET # STORIES141 11
II (000)
V (000)
(ASSUMED EXISTING TYPE)
(STORIES ABOVE LEVEL OF DISCHARGE PER NFPA 101 4.6.3)
MIXED OCCUPANCY:
NO YES SEPARATION: HR. EXCEPTION:
OCCUPANCY
BLDG AREA
PER STORY
(ACTUAL)
11 HEALTHCARE
10 HEALTHCARE
9 BUSINESS
BUILDING AREA
8 BUSINESS
PRIMARY
SECONDARY BASED
OFF 2017 LSA PRIMARY
SECONDARY BASED
OFF 2017 LSA
13,788
21,044
21,914
26,680
7 HEALTHCARE
6 HEALTHCARE
5 BUSINESS
4 BUSINESS
29,714
30,543
42,886
3 HEALTHCARE
2 HEALTHCARE
1 BUSINESS
G BUSINESS
81,701
78,355
91,011
80,210
FIRE PROTECTION REQUIREMENTS *
LIFE SAFETY PLAN SHEET #:
BUILDING ELEMENT
FIRE
SEPARATION
DISTANCE (FEET)
STRUCTURAL FRAME, INCLUDING
COLUMNS, GIRDERS, TRUSSES
DETAIL #
AND
SHEET #
RATING
PROVIDED
REQ'D
(HRS)
BEARING WALLS
EXTERIOR
INTERIOR
FLOOR CONSTRUCTION, INCLUDING
SUPPORTING BEAMS AND DECKING
ROOF CONSTRUCTION, INCLUDING
SUPPORTING BEAMS AND DECKING
SHAFTS-EXIT
SHAFTS-OTHER
CORR. SEP.
OCC'Y SEP. (C)
PARTY/FIRE WALL SEP.
SMOKE BARRIER SEPARATION
TENANT SEP.
INCID. USE SEP.
* INDICATE SECTION NUMBER PERMITTING REDUCTION
N/A -- --
N/A -- --
N/A -- --
2 --
1.5
N/A -- --
1.5 --
G-005, G-006, G-007
PROJECT DESCRIPTION:
FIRST FLOOR RENOVATION OF 12,938 S.F. EXISTING SPACE AND NEW 3,726 S.F. ADDITION FOR A NEW
MENTAL HEALTH OUTPATIENT DEPARTMENT. SECOND FLOOR RENOVATION OF 2,890 S.F. EXISTING
SPACE TO CREATE A NEW POLICE OFFICE.
LIFE SAFETY PLAN REQUIREMENTS
MECHANICAL SUMMARY - SEE MECHANICAL DRAWINGS
ELECTRICAL SUMMARY - SEE ELECTRICAL DRAWINGS
FIRE AND/OR SMOKE RATED WALL LOCATIONS
ASSUMED AND REAL PROPERTY LINE LOCATIONS
EXTERIOR WALL OPNEING AREA WITH RESPECT TO DISTANCE TO ASSUMED
PROPERTY LINES
EXISTING STRUCTURES WITHIN 30' OF THE PROPOSED BUILDING
OCCUPANCY TYPES FOR EACH AREA
OCCUPANT LOADS FOR EACH AREA
EXIT ACCESS TRAVEL DISTANCES
COMMON PATH OF TRAVEL DISTANCE
DEAD END LENGTHS
CLEAR EXIT WIDTHS FOR EACH EXIT DOOR
MAXIMUM CALCULATED OCCUPANT LOAD CAPACITY EACH EXIT DOOR CAN
ACCOMMODATE BASED ON EGRESS WIDTH
ACTUAL OCCUPANT LOAD FOR EACH EXIT DOOR
A SEPARATE SCHEMATIC PLAN INDICATING WHERE FIRE RATED FLOOR/
CEILING AND/OR ROOF STRUCTURE IS PROVIDED FOR PURPOSES OF
OCCUPANCY SEPARATION
LOCATION OF DOORS WITH PANIC HARDWARE
LOCATION OF DOORS WITH DELAYED EGRESS LOCKS AND THE AMOUNT OF
DELAY
LOCATION OF DOORS WITH ELECTROMAGNETIC EGRESS LOCKS
LOCATION OF DOORS EQUIPPED WITH HOLD-OPEN DEVICES
LOCATION OF EMERGENCY ESCAPE WINDOWS
THE SQUARE FOOTAGE OF EACH FIRE AREA
THE SQUARE FOOTAGE OF EACH SMOKE COMPARTMENT
NOTE ANY CODE EXCEPTIONS OR TABLE NOTES THAT MAY HAVE BEEN
UTILIZED REGARDING THE ITEMS ABOVE
STRUCTURAL DESIGN - SEE STRUCTURAL DRAWINGS
EMERGENCY LIGHTING:
EXIT SIGNS:
FIRE ALARM:
SMOKE DETECTION SYSTEMS:
PANIC HARDWARE:
LIFE SAFETY SYSTEM REQUIREMENTS
NO YES
NO YES
NO YES
NO YES
NO YES
PARTIAL
SEE SHEET S-001 FOR STRUCTURAL
CODE AND DESIGN CRITERIA
DESIGN
PROFESSIONAL FIRM NAME LIC.# PHONE#
CONSTRUCTED:
ADDITION:
ORIGINAL USE(S):
CURRENT USE(S):
PROPOSED USE(S):
FIRE
PROTECTION:
RETAINING
WALLS >5' HIGH:
STRUCTURAL:
MECHANICAL:
ELECTRICAL:
FIRE ALARM:
PLUMBING:
CODE ENFORCEMENT JURISDICTION:
ARCHITECTURAL:
CIVIL:
OWNER OR
OWNED BY: FEDERAL CITY/COUNTY PRIVATE STATE
NAME OF PROJECT:
PROPOSED USE:
ADDRESS:
OTHER:
STATE
COUNTY
WILKES-BARRE - EXPAND MENTAL HEALTH CLINIC
1111 EAST END BLVD, WILKES-BARRE, PA ZIP CODE: 18711
HEALTHCARE
CITY
APOGEE CONSULTING WALTER VAN SCOTER OHARC.1716954 (919) 535-5917
APOGEE CONSULTING JOHN KEVIN MASON
NEW CONSTRUCTION ADDITION UPFIT
RECONSTRUCTION ALTERATION REPAIR RENOVATION
HOSPITAL
UNITED STATES DEPTARTMENT OF VETERAN AFFAIRS
(919) 858-7420
FEDERAL DEPT OF VETERAN AFFAIRS
PA 085263
APOGEE CONSULTING JOHN KEVIN MASON (919) 858-7420PA 085263
APOGEE CONSULTING SEAN REID (919) 535-37690402064126
APOGEE CONSULTING SEAN REID 040264126
APOGEE CONSULTING RAJESH KAUL -028706
SCOPE TYPE:
HOSPITAL
HOSPITAL
FORESITE GROUP JANICE WEAVER
FORESITE GROUP (770) 368-1399CLAY MASSEY
(770) 368-1399
(919) 535-3769
PE 038853
38677
132,6471,328
ALL NEW STRUCTURAL STEEL COLUMNS AT THE MENTAL HEALTH ADDITION TO BE
FIREPROOFED VIA INTUMESCENT PAINT. SUBMITTAL REQUIRED.
ALL NEW ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS AND DECKING AT THE
MENTAL HEALTH ADDITION TO BE FIREPROOFED - CONTRACTOR'S CHOICE:
INTUMESCENT PAINT OR SPRAY ON FIREPROOFING. SUBMITTAL REQUIRED.
ALL STRUCTURAL STEEL AND NEW ROOF DECKING AT AHU ENCLOSURE TO BE
FIREPROOFED VIA INUMESCENT PAINT. SUBMITTAL REQUIRED.
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1 /2
:4
:5
P M
C U s e rs
\g s c o tt \D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h g s c o tt a c g -p a .c o m
.r v t
G-004
CODE INFORMATION
4 12GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 DECEMBER 15, 2023
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
CODE STANDARDS AND
EXECUTIVE ORDERS
STORE
CB-18C
CB-18A
LOCKER
CB-22
FORMS RM
CB-23
STORAGE
CB-25
STORAGE
CB-26
OFFICE
CB-28
SHUTTER
ROLLING
ROLL UP DOOR
EWC
FRZ FRZ
REF
REF
FEC
WORK STATION
UP
UP
UP
DN
UP
UP
UP
UP
UP
S S
S S
S S
S
SSS
S
S S S S SS S S
S S
S
SS S S S
S S
S S
S
S
S
S S
S S
S S
S S
S S
S S
SS
S S
S S
S S
SS SS
S SS
EGRESS PATH
EGRESS PATH TAG
EGRESS IDENTIFICATION
AREA OF REFUGE
HAZARDOUS LOCATION
FIRE EXTINGUISHER CABINET
FIRE BLANKET CABINET
CONSTRUCTION MATERIALS
ACCESS ROUTE
XXX
FEC
FBC
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH
EGRESS
CAPACITY
A
B A
B A
G-005
BIO-TERRORISM
CACHE
NB-124
OUTDATED
STOCK
STORAGE
NB-125A
BULK
STORAGE
NB-125
PHARM
CHIEF
NB-123 SECY
NB-122
CONTROL
RM
NB-121
LOCK
OUT
A101
CASHIER
NB-119
NB-115
NB-116
CHECK
IN
NB-114
TREATMENT
RM
NB-112
TREATMENT
RM
NB-111
TREATMENT
RM
NB-110A
TREATMENT
RM
NB-110B
OXYGEN
STORAGE
NB-136
CORRIDOR
NB-108B
RM
NB-108
REPRODUCTION
NB-109
SORTING
BOX
RM
NB-107
BOX
NB-107A
TREATMENT
RM
NB-106
TREATMENT
RM
NB-104
TREATMENT
RM
NB-102
VAN
COORDINATOR
NB-101
WAITING
RM
NB-98
STAIR
WAREHOUSE
L1-100HM
L1-100C
L1-100B
L1-100A
REFR
CB-70
REFR
CB-71
REFR
CB-71A
STORAGE
CB-72
CB-73
CB-76
CB-74
CB-79
CB-80
CB-78
CB-77
CB-80
CORRIDOR
CB-80E
CORRIDOR
CB-69
CORRIDOR
LD-2
CORRIDOR
CB-49
WM
CB-51
REFR
CB-53
REFR
CB-2
CORRIDOR
CB-54
CB-55
PUMP
RM
CB-51A
CORRIDOR
EB-48
EMS
OFFICE
EB-45
OFFICE
CB-28
STORAGE
CB-26STORAGE
CB-25
FORMS
RM
CB-23
LOCKER
CB-22
TOILET
CB-21
STAIR
CB-20B
CORRIDOR
CB-48
CB-20
MECH
CB-20A
CB-18
OFFICE
CB-16B
CB-19
CB-18B
CB-18B
CB-18A
STORE
CB-18C
ELECTRICAL
CB-11
CB-16A
CONFERENCE
RM
CB-16
CB-14
TOILET
CB-15
ELECTRICAL
CB-8ESTORAGE
CB-8D
CB-9
ELECTRICAL
CB-8
COMMAND
CENTER
CB-10
KITCHENETTE
CB-12MECH
CG-29
CORRIDOR
CB-2
X-RAY
RM
CG-17
CORRIDOR
CB-1
STAFF
LOUNGE
CG-22
LOCKER
AG-22
LOCKER
AG-22
ON
CALL
CG-24
CONF.
CB-26
ADMIN
OFFICE
CB-12
ADMIN
OFFICE
CB-14
CB-64
OFFICE
OFFICE
CB-65
REFR
CB-68
REFR
CB-67
CORRIDOR
CB-61A
CB-61
CB-56
SIGN
PAINTER
CB-57
OFFICE
CB-58
OFFICE
CB-59CB-59ACB-60
CB-61B
CB-61C
CB-61
HAC
CB-62
CB-62A
ELEC
CB-60A
CORRIDOR
CB-81
ELEV
ELEV
ELEV
ELEV
ELEV
ELEV
CORRIDOR
CB-136
REFR
CB-80G CB-80B
NB-108A NB-109A
ELEV.
ELEV.
HAC
NB-96
OUT-PAT
SUPV
CB-92B
OUT-PAT
SUPV
CB-92CCLERK
PUR
AGENT
CB-92A
OUT-PAT
PHARMACY
CB-91
CONSULT
RM
NB-129B
CONSULT
RM
NB-128B
CORRIDOR
NB-134
WAITING
RM
NB-127
CORRIDOR
NB-133
OUT-PAT
AREA
ACTIVE
STORAGE
WORK
AREA
PHARMACISTS
CONTROLLED
SUBSTANCES
VAULT
CB-93A
BULK
STORAGE
IN-PAT
WORK
AREA
CB-90
CORRIDOR
CB-135
OFFICE
AB-14
OFFICE
AB-15
OFFICE
AB-13
COFFEE
SHOP
AB-12
TOILET
AB-49
CORRIDOR
AB-47
POLICE
OFFICE
AB-46
COPY
NB-130A
OFFICE
CLINICAL
PHARMACY
NB-130D
OFFICE
CLINICAL
PHARMACY
NB-130F
PROF
OFFICE
NB-130E
TLT
AB-48
OFFICE
CLINICAL
PHARMACY
NB-130C
OFFICE
CLINICAL
PHARMACY
NB-130B
ELECTRICAL
AB-46A
STAIR
COFFEE
SHOP
AB-10
CORRIDOR
AB-10A
VESTIBULE
AB-1A
WAITING
AB-22
WAITING
AB-24
CORRIDOR
AB-1
OFFICE
AB-41
ATRIUM
AB-100
LOCKERS
CB-88A
TLT
CB-88B
HSKPG
CB-85
STAFF
LOUNGE
CB-88
CB-84
ANTE
CB-89A
CHEMO
IV
PREP
CB-89C
IV
PREP
CB-89B
IV
STORAGE
CB-89D
STAFF
TLT
AG-22C
STAFF
TLT
AG-22D
STAFF
TLT
AG-24A
SOILED
UTILITY
CG-19
EXAM-10
AG-53
EXAM-9
AG-55
EXAM-8
AG-57
EXAM-7
AG-59
STORAGE
AG-40E
CLEAN
SUPPLY
AG-40D
EXAM
AG-41
MECH
AG-40B
EXAM
AB-43
EXAM
AB-45
RESUCITATION
AB-37
DECON
AB-39
EXISTING
AMBULANCE
ENTRANCE
AB-31
HK
AB-38B
SOLID
AB-38A PATIENT
TLT
AB-3A
EXAM
AB-36
ELECTRICAL
CORRIDOR
AB-3
WOMEN'S/BARIATRIC
EXAM
AB-34
ISO
EXAM
AB-32
TRIAGE
AB-25
TRIAGE
AB-27
FAST
TRACK
AB-23
CORRIDOR
AB-2
AB-23
MECH
CORR.
AB-20
FAST
TRACK
AB-21
CORRIDOR
AB-2
RCEPTION/SECURITY
AB-24
ELECTRICAL
AB-024B
ELEVATOR
S-1
ELEVATOR
S-2
ELEVATOR
S-3
ELEVATOR
LOBBY
AB-6
ELEV
P-3
ELEV
P-2
ELEV
P-1
TLT
AB-6A
STAIR
MEDICATION
AB-44
PSYCH
ANTE
AB-56
CAPACITYCLR
EXTERIOR
EXIT
70" 233
DN
_____A-402
CORRIDOR
(LOADING
DOCK)
LD-2
REFR.
CB-53
CORRIDOR
CB-59
WM
CB-51
CORRIDOR
CB-54C-61C
A-402
AREA OF WORK LIMIT LINE
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1 /2
:4
:0
P M
C U s e rs
\g s c o tt \D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h g s c o tt a c g -p a .c o m
.r v t
G-005
GROUND FLOOR LIFE SAFETY PLAN
5 12GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 DECEMBER 15, 2023
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
NORTH
0 8 16 32
LIFE SAFETY LEGEND
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
BASED ON LIFE SAFETY PLANS PROVIDED BY THE VA
DATED 04-20-17. THE OCCUPANCY OF THE FLOOR
ABOVE FOR COMPARTMENT 1B.2 IS 172 PERSONS.
WORST CASE SCENARIO - ALL OCCUPANTS FROM 1B.2
USE STAIR AND ALL OCCUPANTS 1/3 OCCUPANTS FROM
BB.2 USE NEW EXIT AT LOADING DOCK.
172 + 140 = 312 OCCUPANTS.
REQUIRED WIDTH OF DOOR = 312 X .2" = 51.6"
PROVIDED - 70"
MAXIMUM ALLOWABLE TRAVEL DISTANCE
(NFPA 101 38.2.6.3) (BUSINESS OCCUPANCY)
300'-0"
Scale: 1/16" = 1'-0"
GROUND FLOOR LIFE SAFETY PLAN
Scale: 1/8" = 1'-0"
GROUND FLOOR PLAN - AREA A, INTERM LIFE SAFTEY
MEASURES
NORTH
0 4 8 16
1 TEMPORARY NEW TREATED WOOD STAIRS,
HANDRAILS AND LANDING TO BE ERECTED PRIOR
TO BEGINNING CONSTRUCTION OF PHASE 1. TO
BE DEMOLISHED UPON COMPLETION OF PROJECT
IN ITS ENTIRETY.
2 EXISTING OVERHEAD ROLL-UP DOOR AT LOADING
DOCK TO BE LOCKED OPEN FOR THE DURATION
OF CONSTRUCTION.
3 NEW MMA3 PARTITION WALL INFILL EXISTING
ROLL-UP DOOR OPENING, WITH 1" INSULATED
METAL PANEL TO EXTERIOR. TO BE SEALED ALL
AROUND, TO BE REMOVED UPON COMPLETION OF
MENTAL HEALTH ADDITION
4 NEW TEMPORARY HM HALF-LITE DOUBLE DOORS
TO BE INSTALLED WITHIN NEW WALL, REMOVED
UPON PROJECT COMPLETION.
CODE SUMMARY
EGRESS PATH "A"
PATH ID LENGTH
A 181' - 5"
TOTAL PATH LENGTH 181' - 5"
LEGEND
UP
DN
UP
DN UP
UP
DN
UP
DN
UP
D N
DN
S SS S S
S S
S SS S
S
SS S
S S
S S
S S
S S
S
S
S
S
S
S
S
S S
S S
S
S S
S S
S S
S SS S S S S S
S S
S
S
S
S
S S SS
SS
S
S
S
S
S S
S S
S
S
S S S S
S S
S S
CONF
ROOM
A1-10
OFFICE
A1-09
OFFICE
A1-09A
EXAM
A1-08
EXAM
A1-11
EXAM
A1-14
EXAM
A1-16
EXAM
A1-07
EXAM
A1-06
EXAM
A1-20
EXAM
A1-15
EXAM
A1-12
EXAM
A1-23
CLEAN
LINEN
A1-02
T L T
A -2
A
EXAM
A1-27
ELEC
A1-03
SOILED
LINEN
A1-29
ELEC
A1-30
ELEV
S-1
ELEV
S-2
ELEV
S-3
ELEV
P-3
ELEV
P-2
ELEV
P-1
ELEVATOR
LOBBY
A1-31A
ATRIUM
CORR
A1-04
CORR
A1-13
STAIR
5T L T
A -0
A
STAIR
VOLUNTARY
C1-77
STOR
C1-78A
ELEC
C1-76
MECH
C1-78
MECH
ELEV
ELEV
ELEV
ELEV
ELEV
ELEV
IT
C1-21B
IT
C1-21C
MECHANICAL
C1-22C
IT
C1-22E
MECH
C1-22
MECHANICAL
C1-146
BASEMENT
ROOF
CHAPEL
21-1
CRAWL
SPACE
CRAWL
SPACE
BASEMENT
ROOF
BASEMENT
ROOF
STAIR
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULTOFFICE/
CONSULT
OFFICE/
CONSULTOFFICE/
CONSULT
GROUP
MEETING
MH
WAITING
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
HAC
FAMILY
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
GROUP
THERAPY
STAFF
BREAK
ROOM
MECHANICAL
CORRIDOR
PATIENT
TOILET
PATIENT
TOILET
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
OFFICE/
CONSULT
STAFF
TLTELEC
TELE-
HEALTH
OFFICE/
CONSULT
ELECTRICALOFFICE/
CONSULT
ELEC MECH
S T
A
IR
STAFF
TLT
STOR
FAMILY
CONSULT
334 SF
NURSE WORK AREA
(7 NURSES)
ELEVATOR
LOBBY
CORRIDOR
CORRIDOR NURSE
WORK
AREA
R E
C E
P T
IO
N
MEDS
EXAM/
OFFICE/
CONSULT
PROCEDURE/
TMS
OFFICE/
CONSULTOFFICE/
CONSULT
EXAM/
OFFICE/
CONSULT
OFFICE/
CONSULT
ELEC.
OFFICE/
CONSULT
EXAM/INJ
NURSE
OFFICE
EXAM/
OFFICE/
CONSULT
VITALS
SUITE
ACCESS
TELE-
HEALTH
SUITE
ACCESS
STAFF
LOCKERS
FAMILY
CONSULT
STOR
MSA
A1-28
STAIR
A1-05
CORR
A1-01
ELEC
A1-22B
HAC
A1-26
CORR
A1-22A
M E
C
H ELEC
ELEC
ELEC21-3
21-4
ALTAR
21-1A
CHAPEL
21-1
CHAPEL
21-1
21-10
21-9
-8
CRAWL
SPACE
E C
D
OFFICE
C1-01B
OFFICE
C1-01A
OFFICE
C1-03A
OFFICE
C1-74
OFFICE
C1-74A
OFFICE
C1-73
OFFICE
C1-72
OFFICE
C1-71
OFFICE
C1-70A
OFFICE
C1-70
C1-01
TOILET
C1-74B
C1-08
STORAGE
1-A
STORAGE
A-B
STORAGE
2-A
STORAGE
2-B
OFFICE
C1-12
OFFICE
C1-09
OFFICE
C1-10
OFFICE
C1-11
OFFICE
C1-06
OFFICE
C1-07
TOILET
C1-14
TOILET
C1-15
MY
HEALTH
VET
C1-05
OFFICE
C1-68
OFFICE
C1-67
OFFICE
C1-66
ROI
C1-02
ROI
WAITING
C1-03
OFFICE/
CONSULT
OFFICE/
CONSULT
NURSE
WORK
AREA(1)
STERILE
SUPPLY
B A
B A
FEC FEC FEC
FEC FEC
FEC
F E
C
FEC
F E
C
FEC
IT
SERVER
RM
C1-19
IT
SERVER
RM
C1-20
IT
SERVER
RM
C1-21A
IT
SERVER
RM
C1-21
WOMEN'S
RESTROOM
C1-64
MEN'S
RESTROOM
C1-63
HAC
C1-62
TR
C1-100A
CAPACITYCLR
EXTERIOR
EXIT
41" 205
CAPACITYCLR
STAIR
EXIT
41" 205
B
SHAFT
EGRESS PATH
EGRESS PATH TAG
EGRESS IDENTIFICATION
AREA OF REFUGE
HAZARDOUS LOCATION
FIRE EXTINGUISHER CABINET
FIRE BLANKET CABINET
CONSTRUCTION MATERIALS
ACCESS ROUTE
XXX
FEC
FBC
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH
EGRESS
CAPACITY
AREA OF WORK LIMIT LINE
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1 /2
:4
:1
P M
C U s e rs
\g s c o tt \D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h g s c o tt a c g -p a .c o m
.r v t
G-006
FIRST FLOOR LIFE SAFETY PLAN
6 12GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 DECEMBER 15, 2023
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
NORTH
0 8 16 32
Scale: 1/16" = 1'-0"
FIRST FLOOR LIFE SAFETY PLAN
LIFE SAFETY LEGEND
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
A. CONTRACTOR TO PROVIDE SHOP DRAWINGS
FOR APPROVAL SHOWING FIREPROOFING FOR
ALL STEEL AND ASSEMBLIES, SHOP DRAWINGS
TO SHOW MATERIALS USED TO ATTAIN FIRE
RATING.
B. WHERE FIRE-RATED CONSTRUCTION IS SHOWN
OR NOTED, CONTACTOR SHALL SUBMIT
CERTIFIED ASSEMBLIES IN ACCORDANCE WITH
SPECIFICATION SECTION 078400 FIRESTOPPING.
THIS INCLUDES PARTITIONS, FLOOR
ASSEMBLIES, ROOF ASSEMBLIES, TOP AND
BOTTOM OF WALL ASSEMBLIES, PENETRATIONS,
AND RECESSED ITEMS.
2021 NFPA 101 38.2.6.3 MAXIMUM ALLOWABLE
TRAVEL DISTANCE - 300'-0"
EGRESS PATH "B"
PATH ID LENGTH
B 228' - 8"
TOTAL PATH LENGTH 228' - 8"
EGRESS PATH "C"
PATH ID LENGTH
C 122' - 10"
TOTAL PATH LENGTH 122' - 10"
EGRESS PATH "D"
PATH ID LENGTH
D 139' - 7"
TOTAL PATH LENGTH 139' - 7"
LEGEND
EGRESS PATH "E"
PATH ID LENGTH
E 188' - 4"
TOTAL PATH LENGTH 188' - 4"
DN
DN
UP
UP
DN
UP
DN
UP
DN
UP
UP
DN
UPDN
S SS
S S
S SS
S
S
S SS S S
S S
S S
S S
S S
S SS
S S
S S
S
S S
S S
S S
S S
SS
S S
S
S S
S S
S S
S
S
S S
S S
S
S S
S
SS
S
SS
S S
S
S
S
S
S
S
S
S SS S
S S
ARMORY
C2-210
TRAINING
ROOM
C2-211
MEN'S
LOCKERS
C2-212
117 SF
MEN'S TLT
WOMEN'S
LOCKERS
C2-214
WOMEN'S
TLT
C2-215
OFFICE
C2-209
OFFICE
C2-208
OFFICE
C2-207
INTERVIEW
ROOM
C2-206
CORRIDOR
C2-200
BREAK
AREA
C2-216
RECEPTION
C2-203
OFFICE
C2-201
OFFICE
C2-202ENTRANCE
C2-204
HOLDING
C2-205
WAITING
TOILET
S T
A
IR
TOUCHDOWN
A2-005
EXAM
RM
A2-007
EXAM
RM
A2-011
TOILET
A2-009A
TOILET
A2-009
OFFICE
A2-010
STAFF
TOILET
A2-008
WAITING
RM
A2-003
TOILET
A2-05A
CHECK
IN
A2-004
CLEAN
LINEN
A2-18
SOILED
A2-017
CORR
A2-006
A2-002
ELEC
A2-019
ELEV
S-1
ELEV
S-2
ELEV
S-3
ELEV
PP-3
ELEV
P-2
ELEV
P-1
ELEC
A2-069
IT
A2-066
WAITING
A2-065
LOCKER
RM
C2-115
OFFICE
C2-113
OFICE
C2-112
OCCUPATIONAL
THERAPY
C2-109
TLT
C2-108
TOILET
C2-106
TOILET
C2-107
MECH
C2-106A
IT
C2-106B
IT
C2-106C
WAITING
C2-105
CHECK IN
C2-104
SOILED
UTILITY/
HOLDING
C2-47
STAIR
S-3
ELEC
C2-46A
ELEC
C2-46
ELEVATOR
LOBBY
C2-45
ELEV
ELEV
ELEV
ELEV
ELEV
ELEV
CORRIDOR
C2-32
VOLUNTARY
STORAGE
C2-44
ELEC
C2-43A
ELEC
C2-43B
OT
CLINIC
C2-43
CLOSET
C2-43A
CARDIAC
REHAB
C2-40
OFFICE
C2-40A
OFFICE
C2-39A
RECREATION
THERAPY
C2-39
MECHANICAL
RM
C2-39B
ELEC
C2-39C
TOILET
C2-41B
TOILET
C2-41A
OT
CLINIC
OFFICE
C2-42
VESTIBULE
MECH
C2-36
TOILET
C2-38
TOILET
C2-37
OFFICE
C2-35
CONF
RM
C2-35A
OFFICE
C2-34 TOILET
C2-33A
BARIATRIC
ULTRASOUND
EXAM
C2-33B
TOILET
C2-33C
SOILED
UTILITY
C2-33D
BARIATRIC
ULTRASOUND
EXAM
C2-33E
ULTRA
SOUND
EXAM
C2-31B
ULTRASOUND
WAITING
C2-29
ULTRASOUND
TECH/FILES
C2-30
ULTRA
SOUND
EXAM
C2-31A
CLEAN
HOLDING
C2-31D
TOILET
C2-31C
CORRIDOR
C2-32
CORRIDOR
C2-32A
CORRIDOR
WAITING
TOILET
EXISTING
ISOTOPIC
PRE/STORAGE
EQUIP
RM
219B
CARDIOLOGY
FILE
RM
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
224OFFICE
STRESS
LAB
BREAK
RM
PRE-TEST
C2-25
CORR
C2-26
OFFICE
C2-24D
OFFICE
C2-24C
OFFICE
C2-24B
STAFF
TRAINING
C2-24A
OFFICE
C2-23
CANTEEN
C2-14
PHYSICAL
THERAPY
C2-22
TOILET
C2-20
C2-21
STORAGE
C2-14F
STORAGE
C2-14E
STORAGE
C2-14D
OFFICE
C2-14C
OFFICE
C2-14B
C2-3C C2-3B
C2-3A
STORAGE
2-133
STAIR
2-003
OFFICE
C2-17
OFFICE
C2-16
OFFICE
C2-15
OFFICE
C2-13
OFFICE
C2-13
STAIR
C2-13
CORR
C2-11
BED
PREPARE
C2-08
OFFICE
C2-04
OFFICE
C2-03
MECH
C2-10
ELEC
C2-02
C2-09
C2-10
STORAGE
C2-05B
OFFICE
C2-05A
RECREATION/
VOLUNTARY
KITCHEN
C2-06
STORAGE
C2-05
TOILET
2-130
TOILET
2-129
STAIR
2-002
GROUP
RM/
KITCHEN
2-114
STORAGE
2-115
HAC
2-116
ROOF
C2-40
OPEN
SHAFT
ATRIUM
C2-40
STAIR
A2-004
MECH
C2-27A
ELEC
C2-27
TOILET
C2-28
ROOF
C2-40
CORRIDOR
A2-001
CORRIDOR
C2-32
CORRIDOR
C2-114
CORRIDOR
A2-65A
A
AB
B
FEC
F
CAPACITYCLR
EXTERIOR
EXIT
41" 205
SLOPE: 1/4"SLOPE: 1/4"
G
EGRESS PATH
EGRESS PATH TAG
EGRESS IDENTIFICATION
AREA OF REFUGE
HAZARDOUS LOCATION
FIRE EXTINGUISHER CABINET
FIRE BLANKET CABINET
CONSTRUCTION MATERIALS
ACCESS ROUTE
XXX
FEC
FBC
CAPACITYCLR
EXTERIOR
EXIT
XX" ###
EXIT
IDENTIFICATION
EGRESS CLEAR
WIDTH
EGRESS
CAPACITY
AREA OF WORK LIMIT LINE
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1 /2
:4
:2
P M
C U s e rs
\g s c o tt \D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h g s c o tt a c g -p a .c o m
.r v t
G-007
SECOND FLOOR LIFE SAFETY PLAN
7 12GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 DECEMBER 15, 2023
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 1/16" = 1'-0"
SECOND FLOOR LIFE SAFETY PLAN
LIFE SAFETY LEGEND
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
NORTH
0 8 16 32
A. CONTRACTOR TO PROVIDE SHOP DRAWINGS
FOR APPROVAL SHOWING FIREPROOFING FOR
ALL STEEL AND ASSEMBLIES, SHOP DRAWINGS
TO SHOW MATERIALS USED TO ATTAIN FIRE
RATING.
B. WHERE FIRE-RATED CONSTRUCTION IS SHOWN
OR NOTED, CONTACTOR SHALL SUBMIT
CERTIFIED ASSEMBLIES IN ACCORDANCE WITH
SPECIFICATION SECTION 078400 FIRESTOPPING.
THIS INCLUDES PARTITIONS, FLOOR
ASSEMBLIES, ROOF ASSEMBLIES, TOP AND
BOTTOM OF WALL ASSEMBLIES, PENETRATIONS,
AND RECESSED ITEMS.
2021 NFPA 101 38.2.6.3 MAXIMUM ALLOWABLE
TRAVEL DISTANCE - 300'-0"
LEGEND
EGRESS PATH "F"
PATH ID LENGTH
F 105' - 2"
TOTAL PATH LENGTH 105' - 2"
EGRESS PATH "G"
PATH ID LENGTH
G 61' - 1"
TOTAL PATH LENGTH 61' - 1"
DN
UP
UP
DN
UP
DN
UP
S SS
S S
S SS
S S
S SS S S
S S
S S
S SS
S S
S S
S
S S
S S
S S
S S
SS
S S
S
S S
S S
S S
S
S
S
S
S
S
S SS S
DN DN
UP
DN
UP
UP
DN
UP
D N
DN
SLOPE
SLOPE
SLOPE
SLOPE
SLOPESLOPE
SLOPE
SLOPE SLOPE
SLOPE
SLOPE
S SS S S
S S
S SS S
S
SS S
S S
S S
S S
S S
S
S
S
S
S S
S S
S
S S
S S
S S
S SS S S S S S
S S
S
S
S
S
S
TOUCHDOWN
A2-005
EXAM
RM
A2-007
EXAM
RM
A2-011
TOILET
A2-009A
TOILET
A2-009
OFFICE
A2-010
STAFF
TOILET
A2-008
WAITING
RM
A2-003
TOILET
A2-05A
CHECK
IN
A2-004
CLEAN
LINEN
A2-18
SOILED
A2-017
CORR
A2-006
A2-002
ELEC
A2-019
ELEV
S-1
ELEV
S-2
ELEV
S-3
ELEV
PP-3
ELEV
P-2
ELEV
P-1
ELEC
A2-069 IT
A2-066
WAITING
A2-065
LOCKER
RM
C2-115
OFFICE
C2-113
OFFICE
C2-112
OCCUPATIONAL
THERAPY
C2-109
TLT
C2-108
TOILET
C2-106
TOILET
C2-107
MECH
C2-106A
IT
C2-106B
IT
C2-106C
WAITING
C2-105
CHECK IN
C2-104
SOILED
UTILITY/
HOLDING
C2-47
STAIR
S-3
ELEC
C2-46A
ELEC
C2-46
ELEVATOR
LOBBY
C2-45
ELEV
ELEV
ELEV
ELEV
ELEV
ELEV
CORRIDOR
C2-32
VOLUNTARY
STORAGE
C2-44
ELEC
C2-43A
ELEC
C2-43B
OT
CLINIC
C2-43
CLOSET
C2-43A
CARDIAC
REHAB
C2-40
OFFICE
C2-40A
OFFICE
C2-39A
RECREATION
THERAPY
C2-39
MECHANICAL
RM
C2-39B
ELEC
C2-39C
TOILET
C2-41B
TOILET
C2-41A
OT
CLINIC
OFFICE
C2-42
VESTIBULE
MECH
C2-36
TOILET
C2-38
TOILET
C2-37
OFFICE
C2-35
CONF
RM
C2-35A
OFFICE
C2-34 TOILET
C2-33A
BARIATRIC
ULTRASOUND
EXAM
C2-33B
TOILET
C2-33C
SOILED
UTILITY
C2-33D
BARIATRIC
ULTRASOUND
EXAM
C2-33E
ULTRASOUND
EXAM
C2-31B
ULTRASOUND
WAITING
C2-29
ULTRASOUND
TECH/FILES
C2-30
ULTRASOUND
EXAM
C2-31A
CLEAN
HOLDING
C2-31D
TOILET
C2-31C
CORRIDOR
C2-32
CORRIDOR
C2-32A
FILE
RM
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
224OFFICE
STRESS
LAB
BREAK
RM
PRE-TEST
C2-25
CORR
C2-26
OFFICE
C2-24D
OFFICE
C2-24C
OFFICE
C2-24B
STAFF
TRAINING
C2-24A
OFFICE
C2-23
CANTEEN
C2-14
PHYSICAL
THERAPY
C2-22
TOILET
C2-20
C2-21
STORAGE
C2-14F
STORAGE
C2-14E
STORAGE
C2-14D
OFFICE
C2-14C
OFFICE
C2-14B
C2-3C C2-3B
OFFICE
C2-17
OFFICE
C2-16
OFFICE
C2-15
OFFICE
C2-13
OFFICE
C2-13
STAIR
C2-13
CORR
C2-11
BED
PREPARE
C2-08
OFFICE
C2-04
OFFICE
C2-03
MECH
C2-10
ELEC
C2-02 C2-09
C2-10
STORAGE
C2-05B
OFFICE
C2-05A
RECREATION/
VOLUNTARY
KITCHEN
C2-06
STORAGE
C2-05
TOILET
2-130
TOILET
2-129
ROOF
C2-40
OPEN
SHAFT
ATRIUM
C2-40
STAIR
A2-004
M E
C H
C -2
A
E L E
C
C -2
TOILET
C2-28
ROOF
C2-40
CORRIDOR
A2-001
CORRIDOR
C2-32
CORRIDOR
C2-114
CORRIDOR
A2-65A
PHASE 1A
PHASE
1C PHASE 1B
AB
B A
TLT
BASEMENT ROOF
CONF
ROOM
A1-10
OFFICE
A1-09
OFFICE
A1-09A
EXAM
A1-08
EXAM
A1-11
EXAM
A1-14
EXAM
A1-07
EXAM
A1-06
EXAM
A1-15
EXAM
A1-12
EXAM
A1-23
CLEAN
LINEN
A1-02
T L T
A -2
A
ELEC
A1-03
ELEC
A1-30
ELEV
S-1
ELEV
S-2
ELEV
S-3
ELEV
P-3
ELEV
P-2
ELEV
P-1
ELEVATOR
LOBBY
A1-31A
ATRIUM
CORR
A1-04
CORR
A1-13
STAIR
5T L T
A -0
A
STAIR
VOLUNTARY
C1-77
STOR
C1-78A
ELEC
C1-76
MECH
C1-78
MECH
ELEV
ELEV
ELEV
ELEV
ELEV
ELEV
IT
C1-21B
IT
C1-21C
MECHANICAL
C1-22C
IT
C1-22E
MECH
C1-22
MECHANICAL
C1-146
CRAWL
SPACE
A1-28
STAIR
A1-05
CORR
A1-01
M E
C
H ELEC
ELEC
ELEC
21-4
CRAWL
SPACE
OFFICE
C1-01B
OFFICE
C1-01A
OFFICE
C1-03A
OFFICE
C1-74
OFFICE
C1-74A
OFFICE
C1-73
OFFICE
C1-72
OFFICE
C1-71
OFFICE
C1-70A
OFFICE
C1-70
C1-01
TOILET
C1-74B
C1-08
STORAGE
1-A
STORAGE
A-B
STORAGE
2-A
STORAGE
2-B
OFFICE
C1-12
OFFICE
C1-09
OFFICE
C1-10
OFFICE
C1-11
OFFICE
C1-06
OFFICE
C1-07
TOILET
C1-14
TOILET
C1-15
MY
HEALTH
VET
C1-05
OFFICE
C1-68
OFFICE
C1-67
OFFICE
C1-66
ROI
C1-02
ROI
WAITING
C1-03
PHASE 1B
PHASE 2B PHASE 2A
B A
B A
IT
SERVER
RM
C1-19
IT
SERVER
RM
C1-20
IT
SERVER
RM
C1-21A
IT
SERVER
RM
C1-21
SHAFT
PHASING LEGEND
PHASE 1A - POLICE SUITE AND
AHU ENCLOSURE
PHASE 1B - TEMP. STAIR TOWER EXIT
AND MENTAL HEALTH
ADDITION SHELL
PHASE 1C - STAIR TOWER EXITS
AND ADJACENT SPACES
PHASE 2A - MENTAL HEALTH SUITE
PHASE 2B - GROUP MEETING,
GANG RESTROOMS, AND
HALLS AND WALLS
DELETE ALL WORK ASSOCIATED WITH THE
NEW SECOND FLOOR POLICE SUITE,
INCLUDING BUT NOT LIMITED TO ALL
ASSOCIATED DEMOLITION AND NEW
CONSTRUCTION.
DEDUCTIVE ALTERNATES:
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1 /2
:4
:2
P M
C U s e rs
\g s c o tt \D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h g s c o…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .