P03 Sole Source BNOE 503-19-112 Repalce Steam System.pdf
PDF 135 KB Posted
- Attached to
- Z1DA--NRM | 503-19-112 Replace Steam System Project (VA-24-00009779) Federal contract opportunity
- Solicitation number
- 36C24424R0001
About this file
This document is a Sole Source Justification related to a federal contract opportunity for the replacement of a steam system at the Altoona VA Medical Center.
The document lists several sole source manufacturers and products required for the project, including ball valves, fire alarm system, HVAC controls, and sprinkler heads. It states that no "equal" products will be considered. It also provides a list of "brand name or equal" products that are required, including pressure relief valves, hydronic pumps, condensate pumps, steam pressure reducing valves, and various steam traps. The project is numbered 503-19-112 and has a performance period of 720 calendar days.
The related federal contract opportunity is a Request for Proposal (RFP) for construction services to replace the steam system at the Altoona VAMC, with a magnitude of construction cost between $5,000,000 and $10,000,000. The solicitation will be issued as a tiered evaluation, considering Service Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, and other small businesses before non-small businesses. A pre-bid conference and site visit are planned.
View the file
Other files for this federal contract opportunity
Show all 40
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
503-315
SOLE SOURCE
In accordance with VAAR clause 852.236-90, RESTRICTION ON SUBMISSION AND
USE OF EQUAL PRODUCTS (NOV 1986)
List of sole source manufacturers and referenced locations for Altoona James E.
VanZandt DEPARTMENT OF VETERANS AFFAIRS VA Medical Center project #503- 19-112 Replace Steam System Project. Contractor is required to use these sole source items without exception. Justifications are included in the bid package.
1. Ball valves shall be “Apollo Conbraco”.
2. Fire alarm system shall be “Honeywell Notifier”.
3. Fire alarm Installer shall be “Bettwy Systems”
4. HVAC controls shall be “Trane Tracer Ensemble”
5. Sprinkler heads shall be “Viking”
Notwithstanding the “Material and Workmanship” clause of this contract, FAR 52.236- 5(a), nor any other contractual provision, “equal” products will not be considered by the Department of Veterans Affairs and may not be used.
BRAND NAME OR EQUAL
Per FAR clause 52.211-6 – the following are basis of design and are required to be brand name or equal:
• 1-SV-BB15F-L. Watts F41 Series Pressure Relief Valves. Drawing M-601.
• 1-SV-BA10-M. Watts F41 Series Pressure Relief Valves Drawing M-601.
• 1-SV-BA10-L. Watts F41 Series Pressure Relief Valves Drawing M-601.
• 1-SV-BE01F-L. Watts F41 Series Pressure Relief Valves Drawing M-601.
• 1-HW-BB12A. Bell & Gossett Hydronic Pump Drawing M-601.
• 1-HW-BB12B. Bell & Gossett Hydronic Pump Drawing M-601.1-CP-BA10a.
Armstrong DPT 300 Series Steam Motive Duplex Condensate Pump with Integral Vented Receiver. Drawing M-601.
• 1-CP-BA10a. Armstrong DPT 300 Series Steam Motive Duplex Condensate Pump with Integral Vented Receiver. Drawing M-601.
• 1-CP-BA10b. Armstrong DPT 300 Series Steam Motive Duplex Condensate Pump with Integral Vented Receiver. Drawing M-601.
• 1-CP-BB12. Armstrong DPT 300 Series Steam Motive Duplex Condensate Pump with Integral Vented Receiver. Drawing M-601.
• 1-CP-BB15F. Armstrong DPT 300 Series Steam Motive Duplex Condensate Pump with Integral Vented Receiver. Drawing M-601.
• 1-CP-BC11. Armstrong DPT 300 Series Steam Motive Duplex Condensate Pump with Integral Vented Receiver. Drawing M-601.
• 1-CP-BE01F. Armstrong DPT 300 Series Steam Motive Duplex Condensate Pump with Integral Vented Receiver. Drawing M-601.
https://www.acquisition.gov/far/current/html/52_233_240.html#wp1113390 https://www.acquisition.gov/far/current/html/52_233_240.html#wp1113390
• 1-SPVR-BB15F-L-1/3. Armstrong Steam Pressure Reducing Valve. Drawing M- 601.
• 1-SPVR-BB15F-L-2/3. Armstrong Steam Pressure Reducing Valve. Drawing M- 601.
• 1-SPVR-BA10-M-1/3. Armstrong Steam Pressure Reducing Valve. Drawing M- 601.
• 1-SPVR-BA10-M-2/3. Armstrong Steam Pressure Reducing Valve. Drawing M- 601.
• 1-SPVR-BA10-L-1/3. Armstrong Steam Pressure Reducing Valve. Drawing M- 601.
• 1-SPVR-BA10-L-2/3. Armstrong Steam Pressure Reducing Valve. Drawing M- 601.
• 1-SPVR-BE01F-L-1/3. Armstrong Steam Pressure Reducing Valve. Drawing M- 601.
• 1-SPVR-BE01F-L-2/3. Armstrong Steam Pressure Reducing Valve. Drawing M- 601.
• LSD-1. Titus FL Series Lineal Slot Diffuser. Drawing M601
• SD-1. Titus FL Series Slot Diffuser. Drawing M601
• Armstrong International. Steameye Monitoring System. Specification 23 21 11 and Specification 23 22 13. Drawing M-701
• All marked 01-H Thermal Steam Humidifiers. Armstrong Model 90, Series 9000.
Drawing M-602.
• 1-ST-1. Armstrong IB-973 Steam Trap. Drawing M-602.
• 1-ST-1-RTUA. Armstrong AIC6 Steam Trap. Drawing M-602.
• 1-ST-1-RTUB. Armstrong AIC6 Steam Trap. Drawing M-602.
• 1-ST-2. Armstrong IB-973 Steam Trap. Drawing M-602.
• 1-ST-AC. Armstrong FT-ICS6 Steam Trap. Drawing M-602.
• 1-ST-AH1. Armstrong IB-973 Steam Trap. Drawing M-602.
• 1-ST-AH2. Armstrong AIC6 Steam Trap. Drawing M-602.
• 1-ST-AH4. Armstrong 1CS6 Steam Trap. Drawing M-602.
• 1-ST-AH-5. Armstrong IB-973 Steam Trap. Drawing M-602.
• 1-ST-AHU-3. Armstrong FT-AIC6 Steam Trap. Drawing M-602.
• 1-ST-AHU-11. Armstrong FT-AIC6 Steam Trap. Drawing M-602.
• 1-ST-AHU-12. Armstrong FT-AIC6 Steam Trap. Drawing M-602.
• 1-ST-DH1. Armstrong 310 Steam Trap. Drawing M-602.
• 1-ST-DH2. Armstrong IB-973 Steam Trap Drawing M-602.
• 1-ST-DWH-1. Armstrong FT-AIC6 Steam Trap. Drawing M-602.
• 1-ST-DWH-2. Armstrong FT-AIC6 Steam Trap. Drawing M-602.
• 1-ST-HX-1. Armstrong FT-AIC6 Steam Trap. Drawing M-602.
• 1-ST-HX-1F69. Armstrong CS6/8 Steam Trap. Drawing M-602.
• 1-ST-HX-2A. Armstrong FT-AIC6 Steam Trap. Drawing M-602.
• 1-ST-HX-2B. Armstrong FT-AIC6 Steam Trap. Drawing M-602.
• 1-ST-HX-3. Armstrong FT-AIC6 Steam Trap. Drawing M-602.
• 1-ST-K. Armstrong ICS4 Steam Trap. Drawing M-602.
• 1-ST-L-SP. Armstrong CS6/8 Steam Trap. Drawing M-602.
• 1-ST-LD. Armstrong CS6/8 Steam Trap. Drawing M-602.
• 1-ST-SPS. Armstrong CS6/8 Steam Trap. Drawing M-602.
• 1-ST-UH-1. Armstrong IB-973 Steam Trap. Drawing M-602.
• 1-ST-UH-2. Armstrong IB-973 Steam Trap. Drawing M-602.
• 1-ST-UH-3. Armstrong IB-973 Steam Trap. Drawing M-602.
• 2-ST-HX-1. Armstrong FT-ICS6 Steam Trap. Drawing M-602.
• 3-ST-B1. Armstrong 1CS6 Steam Trap. Drawing M-602.
• 3-ST-HX-1. Armstrong FT-1CS6 Steam Trap. Drawing M-602.
• 7-ST-HX-1. Armstrong FT-1CS4 Steam Trap. Drawing M-602.
• 32-ST-DWH-1. Armstrong 1CS6 Steam Trap. Drawing M-602.
• 32-ST-HX-1. Armstrong CS6/8 Steam Trap. Drawing M-602.
• 32-ST-HX-2. Armstrong CS6/8 Steam Trap. Drawing M-602.
• Procore Technologies, Inc. Specification 01 31 23 (2.1A) – Project Website.
• Electromagnetic Water Flow Sensor. Onicom F3500. Specification 23 09 23
(2.9E)
• CO2 Sensor. Veris CWE. Specification 23 09 23 (2.9N.2)
• Bi-Directional Through Wall Differential Pressure Sensor. TSI 80024.
Specification 23 09 23 (2.9.O)
• Magnetic Door Contact Switch. Interlogic 2500. Specification 23 09 23 (2.9P)
• Ari Flow Measuring Station. Ebtron GTx108-F. Specification 23 09 23 (2.9P)