Justification MPT-SAT 03-Trane Tracer Ensemble_Redacted.pdf

PDF 276 KB Posted

Attached to
Z1DA--NRM | 503-19-112 Replace Steam System Project (VA-24-00009779) Federal contract opportunity
Solicitation number
36C24424R0001
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4

About this file

This document is a Justification for Limiting Sources under Micro-Purchase Threshold (MPT) up to the Simplified Acquisition Threshold (SAT) for acquiring Trane Tracer Ensemble Building Automation System. The justification cites the unique technical requirements and interoperability needs that can only be met by the Trane Tracer Ensemble system, as it is the existing system installed and maintained at the facility. The justification is for a federal contract opportunity related to replacing the steam system at the Altoona VA Medical Center, with an estimated construction value between $5-10 million. The solicitation will be issued as an RFP open to Service-Disabled Veteran-Owned Small Businesses (SDVOSB), Veteran-Owned Small Businesses (VOSB), and other small businesses, with the NAICS code 236220 Commercial & Institutional Building Construction. A pre-bid site visit is planned for December 13, 2023 at 10:00 AM. Offerors must be registered in SAM and verified in the VA's CVE at the time of proposal submission.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--NRM | 503-19-112 Replace Steam System Project (VA-24-00009779), newest first.
File Type Posted
36C24424R0001 0004 10-23-24.pdf PDF
36C24424R0001 0004_1 10-23-24.pdf PDF
EXHIBIT D - Sample Transmittal Letter for Past Performance Evaluation 36C24424R0001 10-11-24.pdf PDF
SCHEDULE Line Item replace steam system w alternate 10-11-24.pdf PDF
36C24424R0001 0003 10-11-24.pdf PDF
36C24424R0001 0003_1.pdf PDF
EXHIBIT E - Past Performance Questionnaire 36C24424R0001 _ Replace Steam System 10-11-24.pdf PDF
36C24424R0001 0002 10-8-24.pdf PDF
Bid RFIs 12.6.23 - 503-19-112 Replace Steam Project.pdf PDF
P03 Sole Source BNOE 503-19-112 Repalce Steam System.pdf PDF
Cast Iron Operational Alert VHA 121621.pdf PDF
VA Directive 1810.pdf PDF
36C24424R0001 0002_1 10-8-2024.pdf PDF
PN 503-19-112 100PCT ACM Specs and Survey.pdf PDF
Bid RFIs - 503-19-112 Replace Steam Project - Dec. 2023.pdf PDF
PN 503-19-112 100PCT Specifications.pdf PDF
General Decision Number PA20240002 08-16-2024.pdf PDF
Water Safety Plan Requirements 11.22.2021.pdf PDF
PN 503-19-112 100PCT Drawings.pdf PDF
Justification-MPT-SAT 01-Apollo Conbraco Ball Valves_Redacted.pdf PDF
Justification MPT-SAT-02-Bettwy Systems_Redacted.pdf PDF
Two Valve Isolation Per VA Directive 1810 Appendix A.pdf PDF
36C24424R0001_3.pdf PDF
36C24424R0001 0001 1-18-24.pdf PDF
Bid RFIs - 503-19-112 Replace Steam Project.pdf PDF
EXHIBIT B - Subcontractor Information and Consent Form 36C24424R0001 _ Replace Steam System.pdf PDF
EXHIBIT A - Past Performance Relevancy Questionnaire 36C24424R0001 _ Replace Steam System.pdf PDF
503-19-112 -CD- Drawings_Part3.pdf PDF
PM-Part808-405-6-Atch1-Limiting Sources Justification MPT-SAT 04 Viking Sprinkler Heads (s) 10-2-23_Redacted(s).pdf PDF
EXHIBIT D - Sample Transmittal Letter for Past Performance Evaluation 36C24424R0001 _ Replace Steam System.pdf PDF
503-19-112 -CD- Drawings_Part2.pdf PDF
36C24424R0001_1 11-16-23.pdf PDF
PM-Part808-405-6 - Atch1MPT-SAT 01-Apollo Conbraco Ball Valves (s) 10-2-23_Redacted (s).pdf PDF
PM-Part808-405-6 Atch1 Limiting Sources Justification MPT-SAT-02-Bettwy Systems (s) 10-2-23_Redacted(s).pdf PDF
EXHIBIT E - Past Performance Questionnaire 36C24424R0001 _ Replace Steam System.pdf PDF
PM-Part808-405-6 Atch1 Limiting Sources Justification MPT-SAT 03-Trane Tracer Ensemble (s) 10-2-23_Redacted (s).pdf PDF
503-19-112 -CD- Drawings_Part1.pdf PDF
503-19-112 - CD - Specifications.pdf PDF
36C24424R0001 12-8-23.pdf PDF
36C24424R0001_2.docx DOCX document
Show all 40

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VHAPM Part 808.405-6 Limiting Sources Attachment 1: Justification for Limiting Sources for Micro-Purchase Threshold up to the SAT

VHAPM Part 808.405-6 Limiting Sources Page 1 of 2 Original Date: 08/30/2017 Revision 03 Effective Date: 03/18/2021

DEPARTMENT OF VETERANS AFFAIRS

FAR 8 – Justification for Limiting Sources (LSJ) For

Limiting Sources (<SAT)

Acquisition Plan Action ID:_503-23-4-5071-0019____________________

1. Contracting Activity: Department of Veterans Affairs, VISN 4, James E. Van Zandt VA

Medical Center, Altoona PA. Station 503. “Justification for Limiting Sources.” Construction Project Number 503-19-112 – Replace Steam System.

2. Description of Action: This facility has a requirement to replace steam systems. As part of the renovation, the replacement of HVAC controls are required. The solicitation for this procurement shall be advertised for a minimum of 30 calendar days in order to obtain competition from qualified Service Disabled Veteran Owned Small Business (SDVOSB) concerns. This Sole Source Product is for the HVAC Controls “Trane Tracer Ensemble”, this action will be awarded as part of the new contract requirement as described above “Renovate Mens and Womens Locker Rooms”.

Name of Proposed Contractor: Trane Pittsburgh Street Address: 400 Business Center Drive City, State, Zip: Pittsburgh, PA 15205 Phone: 888-690-0280

3. Description of Supplies or Services: Tracer Ensemble HVAC Controls manufactured and programmed by Trane. These controls are facility standard. The facility stocks and maintains Trane controls components only. These controls are installed throughout the hospital and the software/programming is proprietary in nature. Therefore, any other controls vendor would incur additional cost of controls integration and components to the existing Trane Building Automation Systems (BAS), as well as substantial duplication of maintenance cost.

VHAPM Part 808.405-6 Limiting Sources Attachment 1: Justification for Limiting Sources for Micro-Purchase Threshold up to the SAT

VHAPM Part 808.405-6 Limiting Sources Page 2 of 2 Original Date: 08/30/2017 Revision 03 Effective Date: 03/18/2021

4. Authority:

Order Against FSS: Authority of the Multiple Award Schedule Program, Title III of the Federal Property and Administrative Services Act of 1949 (41 USC 251, et seq.); Title 40 USC 501, Services for Executive Agencies; and Section 803 of the National Defense Authorization Act of 2002 (PL 107-107) and implemented by FAR 8.405-6. Mark the applicable exception:

An urgent and compelling need exists, and following the procedures would result in unacceptable delays(FAR 8.405-6(a)(1)(i)(A);

Only one source is capable of providing the supplies or services required at the level of quality required because the supplies or services are unique or highly specialized;

(FAR 8.405-6(a)(1)(i)(B));

In the interest of economy and efficiency, the new work is a logical follow-on to an original Federal Supply Schedule order and the original order was placed in accordance with the applicable Federal Supply Schedule ordering procedures. The original order was not previously issued under sole-source or limited-sources procedures (FAR 8.405- 6(a)(1)(i)(C)); or

Items peculiar to one manufacturer. An item peculiar to one manufacturer can be a particular brand name, product, or a feature of a product, peculiar to one manufacturer). A brand name item, whether available on one or more schedule contracts, is an item peculiar to one manufacturer (FAR 8.405-6(b)).

5. Rationale/explanation to support cited authority: The HVAC controls manufactured by Trane are currently the hospital’s standard. Only Trane OEM Factory Building Automation Systems Technicians can provide programing, service, and maintenance for Trane Tracer Summit controls equipment. Should another controls provider be utilized for the new air handlers, there would be the need to hire a controls integrator to facilitate the integration of the new controls with the existing Trane Tracer Summit BAS. The “duplication of cost” is a factor when required to hold multiple maintenance contracts for the separate controls systems due to their proprietary nature.

6. Note that this determination satisfies the requirements of FAR 8.405-6. The requirement to prepare a written justification IAW FAR 6.303 does not apply to Federal Supply Schedules.

Elijah McIntosh Contracting Officer Construction Team West/NCO 04 Date: _______________

2023-04-21T14:21:23-0400
ELIJAH MCINTOSH

File details come from the government source that posted it. Updated .