25R5001 - Attachment 0073 - Personnel Licensing and Certs.pdf

PDF 472 KB Posted

Attached to
Base Operations Support Services - Fort Hamilton, NY Federal contract opportunity
Solicitation number
W15QKN-25-R-5001
Issued by
Department of the Army Materiel Command Contracting Command Picatinny Arsenal

About this file

This document contains the Minimum Personnel and License Requirements for a federal contract opportunity for Base Operations Support Services at Fort Hamilton, NY. The key details are:

The contract requires a Program Manager with at least 3 years of administrative/supervisory experience managing a similar contract, and an Alternate Program Manager. All supervisors and managers of hands-on workers must have at least 5 years of construction trade experience or an engineering degree. The contractor must provide two experienced electricians, two licensed or journeyman boiler mechanics, two licensed or journeyman plumbers, two journeyman HVAC mechanics, and a licensed locksmith. The contractor must also provide licensed and certified pest management specialists. All contractor personnel must be legal U.S. residents, communicate in English clearly, and comply with conduct standards. The contractor may be required to provide a New York State licensed engineering firm. This contract opportunity is a 100% HUBZone small business set-aside with a Firm Fixed Price contract type and anticipated 11-month base period with 4 option years.

View the file

Other files for this federal contract opportunity

Other files attached to Base Operations Support Services - Fort Hamilton, NY, newest first.
File Type Posted
25-R-5001 - GFP List (d 12.09.2024).xlsx XLSX spreadsheet
25-R-5001 - Industry Questions List w. Answers (Final).xlsx XLSX spreadsheet
Tech Exhibit 0806 Secretary of the Interior Standards for the Treatment of Historic Places.pdf PDF
25R5001 - Tech Exhibit 0419 Elevators_dumbwaiters_wheelchair lifts.docx DOCX document
25R5001 - Tech Exhibit 0009 Levels of Service.pdf PDF
25-R-5001 - BASOPS CDRLs A001_A057.pdf PDF
DBA_WD_New York_NY20240003_Mod._No._9_Rev._Date_09.27.2024.txt TXT text file
25-R-5001 - Site Visit Attendees List.docx DOCX document
25R5001 - Attachment 0073 - Personnel Licensing and Certs (v1).pdf PDF
25-R-5001 - Solicitation Amendment 0006.pdf PDF
25-R-5001 - Solicitation Amendment 0005.pdf PDF
25-R-5001 - Solicitation Amendment 0003.pdf PDF
25R5001 - Tech Exhibit 0205 Irrigation Systems.docx DOCX document
25R5001 - Tech Exhibit 0010 Priority Facilities.docx DOCX document
25R5001 - Tech Exhibit 0509 Backflow Preventers.xlsx XLSX spreadsheet
25R5001 - Attachment 0074 - Accounting System Checklist.pdf PDF
25R5001 - Tech Exhibit 0504 Uninterruptible Power Supply (UPS) Systems.docx DOCX document
25R5001 - Tech Exhibit 0805 Heating and Cooling.docx DOCX document
25R5001 - Tech Exhibit 0416 Hood Systems.docx DOCX document
25R5001 - Tech Exhibit 0501 Utilities Not Included.docx DOCX document
25R5001 - Tech Exhibit 0414 Fire Alarm Systems.docx DOCX document
25R5001 - Tech Exhibit 0408 Hot Water Tanks.docx DOCX document
25R5001 - Tech Exhibit 0405 Gates and Dock Levelers.docx DOCX document
25R5001 - Tech Exhibit 0403 Automatic Doors.docx DOCX document
25R5001 - Tech Exhibit 0303 Priority Pavement Clearing.docx DOCX document
25R5001 - Tech Exhibit 0402 Eye Washes and Safety Showers.docx DOCX document
25R5001 - Tech Exhibit 0009 Levels of Service.docx DOCX document
25R5001 - GFP List (d 06.11.2024).xlsx XLSX spreadsheet
25R5001 - Annex B - Facilities Maintenance Instruction.pdf PDF
25R5001 - Annex G Pavement Clearance Snow-Ice-Sand Removal PWS.pdf PDF
W15QKN-25-R-5001 - BASOPS Services - Solicitation (Released).pdf PDF
25R5001 - Tech Exhibit 0807 Utilities Map.docx DOCX document
25R5001 - Tech Exhibit 0602 ArMA.pdf PDF
25R5001 - Tech Exhibit 0808 Natural Gas Utility Map.docx DOCX document
25R5001 - Tech Exhibit 0901 Paving Plan.docx DOCX document
25R5001 - Tech Exhibit 0605 GSA VEHICLES.pdf PDF
25R5001 - Tech Exhibit 0601 IBE list per building GFEBS 2019_Revised.xlsx XLSX spreadsheet
25R5001 - Tech Exhibit 0603 lead lag procedures in the buildings.docx DOCX document
25R5001 - Tech Exhibit 0412 Auxiliary Generators.xlsx XLSX spreadsheet
25R5001 - Tech Exhibit 0410 Gas and Oil fired boilers.docx DOCX document
25R5001 - Tech Exhibit 0415 Sprinkler Systems.docx DOCX document
25R5001 - Tech Exhibit 0409 Grease Traps.docx DOCX document
25R5001 - Tech Exhibit 0407 Sump Pumps.docx DOCX document
25R5001 - Tech Exhibit 0008 Personnel Licensing and Certs.docx DOCX document
25R5001 - Annex A - Performance Work Statement (PWS).pdf PDF
25R5001 - Tech Exhibit 0201 Grass Areas for Grounds Maintenance.pdf PDF
25R5001 - Tech Exhibit 0502 Water Distribution Systems.pdf PDF
25R5001 - Tech Exhibit 0508 Fire Hydrant Map.pdf PDF
25R5001 - Tech Exhibit 0202_Bioretention Areas.pdf PDF
25R5001 - Tech Exhibit 0301 Sweeping and Snow Removal Areas.docx DOCX document
Show all 50

Base Operations Support Services - Fort Hamilton, NY has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Minimum Personnel and License Requirements, Project Support, and Plans Work

Minimum Personnel & License Requirements

The Contractor shall inspect, repair, and maintain systems and components associated with facilities listed in real property records as required throughout this contract utilizing properly trained, skilled, and qualified employees or subcontractor personnel. The Contractor shall provide evidence of key personnel qualifications and years of experience to the KO for review and acceptance.

Program Manager (PM) and Alternate Program Manager (APM) - The Contractor shall provide a Program Manager who is responsible for the performance of the work. The Program Manager shall have full authority to act for the Contractor on all contract matters relating to daily operation of the contract. The name of the Program Manager shall be provided by the Contractor to the KO.

The Contractor shall provide an Alternate Program Manager to act as the PM in their absence. The APM can additionally be a supervisor or manager for a particular aspect of the contract (e.g.

mechanical section supervisor).

The PM shall have a minimum of three (3) years of administrative and/or supervisory experience managing a contract of this size and scope with similar responsibilities and technical skills and requirements.

The PM shall also hold a 4 year engineering degree from a college accredited by an agency or association recognized by the US Department of Education. The engineering degree must be in the mechanical, electrical or civil engineering fields.

The PM will not be required to hold an engineering degree if the Alternate PM holds a 4 year engineering degree from a college accredited by an agency or association recognized by the US Department of Education. The engineering degree must be in the mechanical, electrical or civil engineering fields.

The individual with the engineering degree will be required to sign off on all technical and project proposals.

The Program Manager shall be available on-site between 0700 - 1600 hours, Monday through Friday except Federal holidays or when the Government facility is closed for administrative reasons.

In addition, the PM or the APM must also be available other hours (e.g. via phone or email) as necessary to address urgent or emergency concerns.

All supervisors and managers of hands-on workers (e.g. electricians, plumbers) of the Contractor’s employees shall have either a minimum of 5 years of hands on experience in a construction trade (e.g. as an electrician, as a plumber), or hold a 4 year engineering degree in the mechanical, electrical or civil engineering field, or a 2 year associates degree in the construction or engineering fields.

The Program Manager and all individuals designated as supervisory or management personnel shall be able to speak, read, and write the English language and communicate clearly.

Certain administrative personnel will require a Common Access Card (CAC) to access Government systems. All employees will require a limited CAC for access to the installation. All Contractor staff shall have, at a minimum, a favorable National Agency Check (NAC) at all times.

All Contractor and subcontractor employees shall be legal U.S. residents. The Contractor shall immediately remove any employee at any point in the contract term that is found to not be a legal U.S. resident. All Contractor personnel shall be able to communicate clearly in the English language.

Contractor Identification. The Contractor shall ensure all personnel be identified as a Contractor to distinguish themselves (e.g., badge, company logo, or uniform) from Government employees. The Contractor shall ensure all correspondence and reports produced are marked as Contractor products or that Contractor participation is disclosed.

Standards of Conduct. Contractor personnel’s conduct shall not reflect discredit upon the Government. The Contractor shall ensure all personnel present a professional appearance while working on the Government installation. The Contractor’s employees shall observe and comply with all local policies and procedures concerning fire, safety, environmental protection, sanitation, security, and possession of firearms or other lethal or illegal weapons or substance. The Contractor shall ensure all Contractor employees, providing services under this contract, conduct themselves and perform services in a professional, safe, and responsible manner. The Contractor shall remove, from the job site, any employee for reasons of misconduct or security. The Contractor shall ensure employee conduct complies with 41 USC 423, Procurement Integrity. The Contractor shall also ensure that no Contractor employees conduct political related activities or events on the installation.

Contractor Hiring Restrictions. The Contractor shall not hire or sub-contract with off duty or former Government employees whose employment would result in a conflict with AR 600-50, Standards of Conduct.

The Contractor staff shall include the services of a New York State licensed engineering firm. This service may be available on a retainer basis per Contractor preference, with engineering services available to be on-site given 24 hour notice. Copies of the retainer agreement must be provided to the Government.

Electricians The Contractor staff on-site shall include two (2) experienced electricians. One of the two electricians must be normally on site during normal operating hours (e.g. both not on vacation at the same time). To meet experience requirements, the electricians must meet one (1) of the following levels of experience.

- a journeyman electrician who has at least seven years of work experience working with tools on installation, alteration, and repair of wiring and appliances for light, heat, and power in/on buildings or comparable facilities.

- have a master of science (M.S.) or a bachelor of science (B.S.) in electrical engineering and:

- For applicants with master degrees, at least two years of experience working with tools on installation, alteration, and repair of wiring and appliances for electric light, heat, and power in/on buildings or comparable facilities

- For applicants with bachelor degrees, at least three years of experience working with tools on installation, alteration and repair of wiring and appliances for electric light, heat and power in/on buildings or comparable facilities.

- a graduate of a vocational, industrial, trade school, or apprenticeship program registered with the New York State Department of Labor specializing in electrical wiring, installation and design or applied electricity, and at least five years of experience working with tools on installation, alteration, and repair of wiring and appliances for electric light, heat, and power in or on buildings or comparable facilities

Boiler Mechanics The Contractor staff on-site shall include two (2) licensed or journeyman boiler mechanics. One of the two boiler mechanics must be normally on site during normal operating hours through the heating months (e.g. both not on vacation at the same time). To meet license requirements, the boiler personnel must either hold a license associated with boiler mechanics or operations from NYC or other municipality in New York State or New Jersey, or have over 5 years of documented experience in hot water boiler and controls work. Other municipal or state licenses will be considered on a case by case basis.

Plumbers The Contractor staff on-site shall include two (2) licensed or journeyman plumbers. One of the two plumbers must be normally on site during normal operating hours (e.g. both not on vacation at the same time). To meet license requirements, the plumbers must either hold a master plumber license or journeyman registration from NYC or other municipality in New York State or New Jersey. Other municipal or state licenses and registrations will be considered on a case by case basis.

HVAC Mechanics The Contractor staff on-site shall include two (2) journeyman HVAC mechanics, with minimum of one on-site during normal operating hours (e.g. both not on vacation at the same time). To meet qualification requirements, the mechanics must either hold a license from NYC or other municipality in New York State or New Jersey, or have over 5 years of documented experience in ventilation and air conditioning and associated controls work. Other municipal or state licenses will be considered on a case by case basis.

A Certificate of Qualification is required to oversee the operation of any air conditioning equipment that contains over 50 pounds of refrigerant. A certificate holder must be on duty at all times when the system is being used.

Locksmith A Locksmith license is required to repair, service, install, inspect, and open and close locks by mechanical means.

Pest Management

Pest Management Business Licenses and Certifications - The Contractor shall provide its business license and pest management specialist’s names, certification numbers (DOD or State), certification categories, and expiration dates with their proposal and annually by end of the performance period.

The Contractor shall ensure that any licenses/certificates and training of Contractor personnel are kept current.

Pest Management Personnel - The Contractor shall perform pest surveillance, pest control, inspection operations, and pesticide application, IAW DODI 4150.07 and Fort Hamilton IPMP. The

Contractor shall have a State pesticide application business license and the Contractor’s pest management specialists shall be Armed Forces Pest Management Board or State of New York certified in the following pest control categories/subcategories:

a. Turf (EPA Category 3/ NYSDEC Category 3B

b. Ornamental (EPA Category 3/ NYSDEC Category 3A

c. Aquatic (EPA Category 5/ NYSDEC Category 5B

d. Mosquito & General Use Pesticides (EPA Category 7/ NYSDEC Category 7)

e. Public Health Pest Management (EPA Category 8/ NYSDEC Category 8)

Weed Control - Reference above section for license requirements for weed control. Contract herbicides management employees shall not apply herbicides under someone else’s certification. If the Contractor spills or releases any hazardous substances (i.e., substances listed in 40 CFR 302, Designation, Reportable Quantities, and Notification), the Contractor shall notify the COR/ACOR and the Environmental Office by written notification within one (1) hour. The Contractor shall submit a consolidated list of all herbicides used during the month, in a monthly herbicide application record, to the COR/ACOR. The Contractor shall only use herbicides listed on the garrison’s Pesticide Use

Plan (PUP). The Contractor shall ensure that the licenses, certificates, and training of Contractor employees applying herbicide are valid and kept current. Copies of these licenses and certifications shall be included with the Offeror’s proposal, and again within ten (10) calendar days upon a change in personnel.

License Requirements for Work Not Addressed Above

The Contractor shall ensure that either Contractor employees meet the requirements of specific areas addressed by New York State and NYC regulation, or that associated subcontractors are certified or licensed in the specific areas required by the State of New York and New York City. The

Contractor shall ensure all required documentation of certification or licensure for Contractor employees are filed with the COR/ACOR within 3 business days prior to employees commencing performance.