This is an Asbestos and Lead-Paint Survey Report for Repair BEQ G703 at Camp Geiger, MCB Camp Lejeune, North Carolina. The survey was conducted by ECS Southeast, LLC on behalf of MBF Architects PA to identify asbestos-containing materials (ACMs) and lead-containing paint (LCP) prior to building renovation. The report was issued January 9, 2026.
The 37,825-square-foot Bachelor's Enlisted Quarters building, constructed in 1980, was surveyed for suspect ACMs and LCP through non-invasive visual inspection (September 18, 2025) and destructive sampling (December 30, 2025). A total of 44 bulk samples from 17 homogeneous areas were submitted to Scientific Analytical Institute, Inc. for Polarized Light Microscopy (PLM) analysis via EPA Method 600/R-93/116. Results from 46 analyzed layers showed none of the materials contained detectable asbestos concentrations. Twenty-three paint chip samples were analyzed for lead concentration using Flame Atomic Absorption Spectroscopy. All paint samples tested below method detection limits for lead. The report notes that unseen ACMs may remain in inaccessible areas such as sub-grade walls, structural members, and areas behind exterior walls. If suspect materials are discovered during construction, they should be presumed to contain asbestos and sampled by a certified asbestos inspector in accordance with 29 CFR 1926.1101. The survey covered interior and exterior areas of both the main G703 building and the detached mechanical building G713.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0013.pdf | ||
| Amend 0011.pdf | ||
| Amend 0012.pdf | ||
| Amend 0010.pdf | ||
| Amend 0009.pdf | ||
| Amend 0008.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0004.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| 25-0010 GEO.pdf | ||
| 25-0051 APPD.pdf | ||
| N4008525B0010 DWG_Signed.pdf | ||
| 25-0010 SID.pdf | ||
| 25-0051 GEO.pdf | ||
| 25-0010 DM for Repair BEQ 702.pdf | ||
| 25-0010 Lead and Asbestos Report.pdf | ||
| 25-0051 DM.pdf | ||
| RFP 250010.pdf | ||
| 25-0051 SID.pdf | ||
| 25-0051 BOD.pdf | ||
| 25-0010 BOD.pdf | ||
| 25-0010 APPD.pdf | ||
| N4008525B0051 DWG_Signed.pdf | ||
| N4008525B0051 Specs.pdf | ||
| N4008525B0010 Specs.pdf |
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS AND LEAD-PAINT SURVEY
REPAIR BEQ G703
CAMP GEIGER
MCB CAMP LEJEUNE, NORTH CAROLINA 28542
ECS PROJECT NO. 49:26342
FOR: MBF ARCHITECTS PA
JANUARY 9, 2026
Braxton B. Dawson Jenny Clark, REM Environmental Senior Project Manager Associate Environmental Principal bdawson@ecslimited.com jclark@ecslimited.com 910-686-9114 404-640-9257
January 9, 2026 Mr. Bill Faulkenberry MBF Architects PA 317-C Pollock Street New Bern, North Carolina 28560 faulkenberry@mbfarchitects.com
ECS Project No. 49:26342
Reference: Asbestos and Lead-Paint Survey, Repair BEQ G703, Camp Geiger, MCB Camp Lejeune, North Carolina
Dear Mr. Faulkenberry:
ECS Southeast, LLC (ECS) is pleased to provide MBF Architects PA with the results of the above referenced Asbestos and Lead-Paint Survey performed for the Repair BEQ G703 project located at Camp Geiger in MCB Camp Lejeune, North Carolina. This report summarizes our observations, analytical results, findings, and recommendations related to the work performed. The work described in this report was performed by ECS in general accordance with the Scope of Services described in ECS Proposal Number 49:50782P and the terms and conditions of the agreement authorizing those services.
ECS appreciates this opportunity to provide MBF Architects PA with our services. If we can be of further assistance to you, please do not hesitate to contact us.
Sincerely, ECS Southeast, LLC
6714 Netherlands Drive, Wilmington, North Carolina 28405 • T:910-686-9114 NC Engineering No. F-1519 NC Geology No. C-553
ECS Florida, LLC • ECS Mid-Atlantic LLC • ECS Midwest, LLC • ECS Pacific, Inc. • ECS Southeast, LLC • ECS Southwest, LLP
ECS New York Engineering, PLLC - An Associate of ECS Group of Companies • ecslimited.com
"ONE FIRM. ONE MISSION."
EXECUTIVE SUMMARY
The subject property is improved with a Bachelor's Enlisted Quarters building located at Camp Geiger in MCB Camp Lejeune, Onslow County, North Carolina. The structure consists of 37,825 square feet and was reportedly originally constructed in 1980. G713 is a detached mechanical building that services G703. At the time of our survey, the subject buildings were occupied and are currently scheduled to be renovated.
The purpose of the survey was to determine whether asbestos-containing materials (ACMs) or lead-containing paint (LCP) are present on the subject property. The survey was performed within the interior and exterior areas of the subject building as well as the roof.
Asbestos Survey
On September 18, 2025, Mr. Braxton B. Dawson, an accredited inspector, performed the initial asbestos assessment. A subsequent destructive sampling scope was performed on December 30, 2025 to determine if damp-proofing mastic on CMU behind exterior brick veneer contained asbestos.
The destructive assessment also included shower pans and vanity mirrors inside the east squadron bay bathrooms on the second floor. Bulk samples were submitted to Scientific Analytical Institute, Inc.
(SAI) in Greensboro, North Carolina for analysis via Polarized Light Microscopy (PLM) in accordance with the current EPA-600 methodology.
A total of 44 bulk samples from 17 homogeneous areas were submitted to the laboratory, of which 46 layers were analyzed from the first sampling event. For destructive testing, 4 more bulk samples from 2 homogeneous areas were submitted to the laboratory, of which 8 additional layers were analyzed. Based on the laboratory analysis of the bulk samples collected during the survey, none of the materials were reported to contain asbestos.
Due to inaccessibility or the destructive means that asbestos sampling requires, unseen ACMs may remain within the building hidden behind inaccessible areas, which include, but are not limited to, sub-grade walls, structural members, topping slabs, sub-grade sealants, flooring located below underlayments, areas behind exterior walls, pipe trenches, and subsurface utilities.
If suspect materials are discovered during construction activities, they should be presumed to contain asbestos and be treated as ACMs or be sampled immediately upon discovery and prior to disturbance for asbestos content by an accredited or certified asbestos inspector in accordance with 29 Code of Federal Regulations (CFR) 1926.1101.
Lead Paint Survey
The lead paint assessment was conducted by the collection of paint chip samples from suspect lead paint materials. The paint chip samples were submitted to a laboratory that participates in the American Industrial Hygiene Association (AIHA) Environmental Lead Proficiency Analytical Testing (ELPAT) Program for analysis of lead concentration (percent by weight) using Flame Atomic Absorption Spectroscopy.
January 9, 2026 ii
Based on the laboratory analysis of the paint chips collected during the survey, none of the building components was reported as lead-containing paint.
Paint and surface coatings that contain detectable concentrations of lead are considered “lead-containing paints.” Since OSHA has no specific action level for lead in paint, all paint on the site found to have a measurable concentration of lead should be assumed to be lead-containing. Work performed that may disturb lead-containing paint is regulated under OSHA, as referenced under 29
CFR 1926.62.
The executive summary is an integral portion of this report; however, ECS recommends that the report be read in its entirety.
iii
PAGETABLE OF CONTENTS
1.0 SITE DESCRIPTION
2.0 PURPOSE
3.0 METHODOLOGY
3.1 Asbestos-Containing Materials
3.2 Lead in Paint and Surface Coatings
4.0 RESULTS
4.1 Asbestos Sampling
4.2 Suspect or Assumed Asbestos-Containing Materials
4.3 Lead in Paint and Surface Coatings
5.0 RECOMMENDATIONS AND REGULATORY REQUIREMENTS
5.1 Asbestos-Containing Materials
5.2 Lead in Paint and Surface Coatings
6.0 LIMITATIONS
iv
TABLE OF APPENDICES
Appendix I: Figures
Appendix II: Site Photographs
Appendix III: Asbestos Bulk Sample Results
Appendix IV: Lead Laboratory Analytical Results
Appendix V: Licenses & Certifications v
1.0 SITE DESCRIPTION
The subject property is developed with Bachelor's Enlisted Quarters (BEQ) Building G703, located at Marine Corps Base (MCB) Camp Geiger in Jacksonville, Onslow County, North Carolina. Based on the information available, BEQ G703 comprises approximately 37,825 square feet of space and was reportedly constructed in 1980. ECS was requested to conduct an asbestos and lead paint survey prior to the proposed renovations. The exterior is comprised of a brick facade, with slab-on-grade, and a metal roof on G703. Interior finishes consist of suspended ceiling tiles, concrete masonry unit (CMU) block, drywall, ceiling texture, and coated concrete floors. G713 is a detached mechanical building that services G703.
2.0 PURPOSE
The purpose of the Asbestos and Lead-Paint Survey was to identify asbestos-containing materials (ACM) and lead-containing paint (LCP) which require special handling and/or disposal if disturbed during construction activities. The identification of ACMs require trained labor, regulated work practices, and special disposal. The identification of LCP or other lead hazards requires disclosure to contractors and monitoring of lead exposure.
3.0 METHODOLOGY
ECS performed the authorized Scope of Services in general accordance with our proposal, standard industry practice(s) and methods specified by regulation(s) for the identification of ACMs and LCPs.
3.1 Asbestos-Containing Materials
The non-invasive asbestos survey was performed by Mr. Braxton B. Dawson (NC Asbestos Inspector No. 12830) on September 18, 2025. The survey consisted of observing the accessible areas of the buildings for the presence of suspect materials that may contain asbestos. The survey involved detecting both friable materials (materials that can be pulverized or reduced to a powder by hand pressure when dry) and non-friable materials (materials that pose a hazard when sawn, sanded, drilled, or pulverized). Homogeneous materials (based on material type, color, texture, etc.) were identified during the survey. A subsequent destructive sampling scope was performed on December 30, 2025 to determine if damp-proofing mastic on CMU behind exterior brick veneer contained asbestos. The destructive assessment also included shower pans and vanity mirrors inside the east squadron bay bathrooms on the second floor.
The EPA National Emissions Standard for Hazardous Air Pollutants (NESHAP) requires a survey for asbestos before renovation or demolition. Demolition is defined under NESHAP as the removal of a load-bearing structural member, and renovation is an action that disturbs building materials. Based on requirements under NESHAP and the North Carolina Asbestos Hazard Management Program (AHMP), administered by the Health Hazards Control Unit (HHCU) for renovation or demolition activities, ECS conducted a limited survey for potential ACM. The ACM survey was limited in that we did not conduct demolition, such as jack/sledgehammering, to expose potentially concealed materials. Samples were collected in general accordance with Environmental Protection Agency
January 9, 2026
ECS Project # 49:26342
(EPA) Standard 40 CFR 763 Subpart E, Asbestos Hazard Emergency Response Act (AHERA), and Occupational Safety and Health Administration (OSHA) Standard 29 CFR 1926.1101 Inspection Protocol.
Representative bulk samples were collected, placed in sealed packages, and submitted to Scientific Analytical Institute, Inc. (SAI) for analysis using the Environmental Protection Agency (EPA) recommended method of Polarized Light Microscopy (PLM) coupled with dispersion staining (Method No. EPA 600/R-93/116). SAI participates in the National Voluntary Laboratory Accreditation Program (NVLAP). Their NVLAP accreditation number is 200664-0. Several of the samples were layered and analyzed as multiple samples. EPA regulations require collecting multiple samples of each homogeneous area for laboratory analysis. The material type, sample location, and analytical results of each bulk sample are also summarized in the attached Asbestos Bulk Analysis report in Appendices.
Samples were analyzed using the “Positive Stop” methodology. If one sample of a homogeneous material is reported to contain asbestos, the remaining samples are not analyzed. If one sample of a material from a homogeneous area is reported to contain greater than 1% asbestos, then by EPA definition, it is characterized as an ACM regardless of additional analysis.
During the survey, ECS attempted to identify suspect ACMs in readily accessible areas. However, due to the destructive means required to identify some materials, certain areas were deemed inaccessible (i.e. behind walls or sub-grade materials) and were not surveyed for suspect ACMs.
3.2 Lead in Paint and Surface Coatings
ECS completed a lead paint screening within the building as part of our assessment activities. The collection of representative paint chip samples was performed throughout the G703 and G713.
Samples collected were containerized, labeled, and transported to SAI. Each of the paint chip samples was subsequently analyzed for the presence of lead, reported in percent lead by weight, via EPA Method SW 846, 7000B (Flame AAS). The chain-of-custody, which includes sample numbers and sample locations, is included in an Appendix of this report.
4.0 RESULTS
The following is a summary of laboratory results, findings and observations.
4.1 Asbestos Sampling
In total, 44 bulk samples from 17 homogeneous areas were submitted to the laboratory, of which 46 layers were analyzed.
An ACM is defined as any material containing more than one percent (>1%) asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, PLM. The U.S. EPA categorizes ACM as follows:
• Friable ACMs are defined as any ACM that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Non-friable ACMs are defined as any ACM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
January 9, 2026
• Category I non-friable ACM includes packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than one percent (>1%) asbestos.
• Category II non-friable ACM is listed as any material, excluding Category I non-friable ACM, containing more than one percent (>1%) asbestos.
Regulated Asbestos Containing Materials (RACM) are friable ACM or non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or has crumbled, been pulverized, or reduced to powder in the course of renovation and/or demolition operations.
SAI submitted a signed final laboratory report to ECS on September 24, 2025 and January 6, 2025.
None of the bulk samples submitted for analysis were reported to contain asbestos in detectable concentrations. A complete list of the sampled materials submitted for analysis and sample locations is included below. Photographs of representative building materials are located in Appendix II of this report.
Asbestos Bulk Sample Locations and Analysis Results
Sample ID Material
Description Sample
Location Analytical
Results Category
Estimated Quantity
First Sample Event, September 18, 2025
01-1,2 Caulk Interior Masonry Joints
None Detected
(ND)
Not Applicable (N/A)
N/A
02-1,2 Floor Coating
Interior ND N/A N/A
03-1,2 Drywall & Joint Compound
Barrack Wing Ceilings
ND N/A N/A
04-1,2,3,4,5, 6,7
Block Coating
Interior Walls
ND N/A N/A
05-1,2 White Mastic
HVAC -
Mechanical Rooms - On Fiberglass
TSI
ND N/A N/A
06-1,2,3,4,5, 6,7
Ceiling Texture
Barrack Wings
ND N/A N/A
07-1,2 Caulk Interior Windows
ND N/A N/A
January 9, 2026
Sample ID Material
Description Sample
Location Analytical
Results Category
Estimated Quantity
08-1,2 Ventilator Duct Sealant
Attic ND N/A N/A
09-1,2 Vent Pipe Tar
Attic ND N/A N/A
10-1,2 Caulk Exterior Doors
ND N/A N/A
11-1,2 Caulk Exterior Windows
ND N/A N/A
12-1,2 Caulk Exterior Masonry Joints
ND N/A N/A
13-1,2 Drywall & Joint Compound
1st Floor Common Areas
ND N/A N/A
14-1,2 Caulk Mechanical Building G713 - Doors
ND N/A N/A
15-1,2 Caulk HVAC - Mechanical Building G713
ND N/A N/A
16-1,2 Caulk Aluminum Jacketed TSI
- HVAC
G713
ND N/A N/A
17-1,2 Backer Board & Stucco
Exterior Soffit
ND N/A N/A
Destructive Sampling Event, December 30, 2025
3-1,2 Damp proofing Black Mastic
Exterior behind Brick Veneer
ND N/A N/A
4-1,2 Tile, Grout, & Mortar Bed
Squadron Bay Showers
ND N/A N/A
January 9, 2026
4.2 Suspect or Assumed Asbestos-Containing Materials
Due to the inaccessibility or the destructive means that asbestos sampling requires, additional suspect ACMs may remain within the building hidden behind inaccessible areas that include but are not limited to sub-grade walls, structural members, topping slabs, sub-grade sealants, flooring located below underlayments, areas behind exterior walls, pipe trenches, and subsurface utilities, etc.
These areas were deemed inaccessible and were not assessed.
If these materials are discovered during construction activities, they should be presumed to contain asbestos and be treated as ACMs or sampled immediately upon discovery and prior to disturbance for asbestos content by a certified asbestos inspector in accordance with 29 CFR 1926.1101.
A subsequent destructive sampling scope was performed on December 30, 2025 to determine if damp-proofing mastic on CMU behind exterior brick veneer contained asbestos. The destructive assessment also included shower pans and vanity mirrors inside the east squadron bay bathrooms on the second floor. The results of the destructive testing are as followed:
• Black damp-proofing mastic was sampled on the CMU behind exterior brick veneer. The mastic was not reported to contain asbestos.
• Shower pan membranes and mastic were not observed in the bathrooms tested. Samples of tile, grout, and mortar bed were submitted and reported to be negative for asbestos.
• The vanity mirrors in the living quarters were determined to be mechanically fastened.
Mirror mastic was not observed.
4.3 Lead in Paint and Surface Coatings
Paint and surface coatings that contain detectable concentrations of lead are considered to be “lead-containing paints” (LCP). Because OSHA has no specific action level for lead in paint, all paint on the site found to have measurable lead concentrations should be assumed to be lead-containing.
Work performed that may disturb lead-containing paint is regulated under OSHA, as referenced under 29 CFR 1926.62.
Lead was not detected above the method detection limit in the paint chip samples analyzed.
Summary Paint Chip Sampling Results
Sample ID Location Substrate Component Condition Color Result
PC-1 Mechanic al Room
Metal Pipe Good Red <0.0057%
PC-2 Common Areas
Metal Door Good Blue <0.0057%
PC-3 Common Areas
Metal Door Frames
Good Blue <0.0044%
January 9, 2026
Sample ID Location Substrate Component Condition Color Result
PC-4 Barracks CMU Walls Good Beige <0.0071%
PC-5 Laundry Drywall Walls Good Beige <0.0052%
PC-6 Interior Stairwell & Lobby
CMU Walls Good Gray <0.0034%
PC-7 Common Areas
CMU Walls Good Beige <0.0073
PC-8 Mechanic al Rooms & Janitor's Closet
CMU Walls Good White <0.0043%
PC-9 Exterior Stairwells
Metal Doors Good Brown <0.0050%
PC-10 Exterior Stairwells
Metal Door Frames
Good Brown <0.0053%
PC-11 Attic Metal Hatch Good White <0.0046
PC-12 Barrack Ceilings
Drywall Ceiling Good White <0.0038%
PC-13 Interior 1st Floor Lounge
CMU Walls Good Beige <0.0042%
PC-14 Interior Drywall Ceiling Good White <0.0039
PC-15 Exterior Doors
Metal Doors Good Brown <0.0065
PC-16 Exterior Doors
Metal Door Frames
Good Brown <0.0061%
PC-17 Exterior Metal Downspo uts
Good White <0.0040
PC-18 Mechanic al Building G713
Metal Door Good Blue <0.0048%
January 9, 2026
Sample ID Location Substrate Component Condition Color Result
PC-19 Mechanic al Building G713
Metal Door Frames
Good Blue <0.0065%
PC-20 Exterior Metal Window Frames
Good Brown <0.0068%
PC-21 Central Entrance/ Exit
Metal Double Doors
Good Gray/Blue <0.0040
PC-22 Central Entrance/ Exit
Metal Double Door Frames
Good Gray/Blue <0.0071%
PC-23 Lobby CMU Walls Good Gray <0.0066%
5.0 RECOMMENDATIONS AND REGULATORY REQUIREMENTS
Based on our understanding of the purpose of the Asbestos and Lead-Paint Survey, the results of laboratory analysis, and our findings and observations, ECS presents the following recommendations.
5.1 Asbestos-Containing Materials
None of the bulk samples submitted to Scientific Analytical Institute, Inc. were reported to contain detectable concentrations of asbestos. If additional suspect asbestos-containing materials are uncovered which were not accessible during this sampling event, it is recommended that these materials be sampled or tested immediately upon discovery for asbestos content by an asbestos inspector in accordance with 29 CFR 1926.1101.
5.2 Lead in Paint and Surface Coatings
Based on laboratory analysis of the paint chip samples collected and analyzed for lead content, lead was not detected above the method detection limit.
6.0 LIMITATIONS
The conclusions and recommendations presented within this report are based upon a reasonable level of assessment within normal bounds and standards of professional practice for a site in this particular geographic setting. ECS is not responsible or liable for the discovery and elimination of hazards that may potentially cause damage, accidents, or injuries.
The observations, conclusions, and recommendations pertaining to environmental conditions at the subject site are necessarily limited to conditions observed, and/or materials reviewed at the time this study was undertaken. No warranty, expressed or implied, is made with regard to the conclusions
January 9, 2026 and recommendations presented within this report. This report is provided for the exclusive use of the client. This report is not intended to be used or relied upon in connection with other projects or by other unidentified third parties without the written consent of ECS and the client.
During this study, samples were submitted for analysis at an accredited laboratory via polarized light microscopy. As with any similar survey of this nature, actual conditions exist only at the precise locations from which samples were collected. Certain inferences are based on the results of this sampling and related testing to form a professional opinion of conditions in areas beyond those from which the samples were collected. No warranty, expressed or implied, is made.
Our recommendations are in part based on federal, state, and local regulations and guidelines. ECS does not assume the responsibility of the person(s) in charge of the site, or otherwise undertake responsibility for reporting to any local, state, or federal public agencies, any conditions at the site that may present a potential danger to public health, safety, or the environment. Under this scope of services, ECS assumes no responsibility regarding any response actions initiated as a result of these findings. General compliance with regulations and response actions are the sole responsibility of the Client and should be conducted in accordance with local, state, and/or federal requirements.
January 9, 2026
Appendix I: Figures
Asbestos & Lead Survey
Figure 1
Site Overview
Repair BEQ G703 Camp Geiger
Jacksonville, North Carolina
ECS Project No. 49-26366
IMAGE SOURCE:
Google Earth
Subject Structure
NOTES:
Floor plan not to scale.
Asbestos & Lead Survey Figure 2
Asbestos Sample Locations
Repair BEQ G703 Camp Geiger
Jacksonville, North Carolina
ECS Project No. 49-26366
XX-XX
SAMPLE LEGEND:
Sample Location
Asbestos Not Detected
Asbestos Detected >1%
Trace Asbestos Detected <1%
1st Floor
RC1
12-1
11-1
10-1
17-2 17-1
13-2
13-1
06-2 06-1
04-1
03-2
RC1
05-2
12-211-2
10-2
16-1,2 15-1,2
07-2
06-3
04-2
01-1
Mech Building G713 14-1,2
Asbestos & Lead Survey Figure 3
Asbestos Sample Locations
Repair BEQ G703 Camp Geiger
Jacksonville, North Carolina
ECS Project No. 49-26366
XX-XX
SAMPLE LEGEND:
Sample Location
Asbestos Not Detected
Asbestos Detected >1%
Trace Asbestos Detected <1%
2nd Floor
06-5
06-4
04-5
04-4 04-3
03-1 02-1
01-2
Asbestos & Lead Survey Figure 4
Asbestos Sample Locations
Repair BEQ G703 Camp Geiger
Jacksonville, North Carolina
ECS Project No. 49-26366
XX-XX
SAMPLE LEGEND:
Sample Location
Asbestos Not Detected
Asbestos Detected >1%
Trace Asbestos Detected <1%
3rd Floor
RC1
09-2
08-2
07-1
05-1
RC1
09-1
08-1
06-7
04-7
04-6
02-2
06-6
Asbestos & Lead Survey Figure 5
Lead Sample Locations
Repair BEQ G703 Camp Geiger
Jacksonville, North Carolina
ECS Project No. 49-26366
1st Floor
SAMPLE LEGEND:
Lead-Containing Paint
Below Detection Limit
XX
Mech Building G713
PC-1
PC-23
PC-22
PC-21
PC-20
PC-11
PC-10PC-9
PC-6
PC-5
PC-4
PC-3
PC-2
Asbestos & Lead Survey Figure 6
Lead Sample Locations
Repair BEQ G703 Camp Geiger
Jacksonville, North Carolina
ECS Project No. 49-26366
2nd Floor
SAMPLE LEGEND:
Lead-Containing Paint
Below Detection Limit
XX
PC-17PC-18
PC-16 PC-15
PC-8
PC-7
Asbestos & Lead Survey Figure 7
Lead Sample Locations
Repair BEQ G703 Camp Geiger
Jacksonville, North Carolina
ECS Project No. 49-26366
3rd Floor
SAMPLE LEGEND:
Lead-Containing Paint
Below Detection Limit
XX
PC-19
PC-14
PC-13
PC-12
Appendix II: Site Photographs
1 - View of G703
2 - View of the back of the building
ECS Project No. 49:26342
3 - View of G713 - Mechanical Building
4 - View of the laundry room
5 - View of the open bay barracks.
6 - View of the squadron bathrooms
7 - Additional view of bathrooms
8 - View of the first floor offices
9 - View of the typical mechanical rooms
10 - View of the attic
11 - View of stairwells
12 - View of exterior stairwells
13 - View of the duty office
14 - View of typical vanity mirrors mechanically fastened
15 - View of non-ACM damp proofing mastic behind brick veneer
16 - View of the squadron showers
17 - View of shower threshold - No Mastic observed
18 - View of exterior repairs
Appendix III: Asbestos Bulk Sample Results
Bulk Asbestos Analysis By Polarized Light Microscopy EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10092582Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Date Amended:
Braxton Dawson Bailey Proctor
PLM
09/19/2025
Project: BEQ 703 Camp Lejune, NC Date Reported: 09/24/2025
10/06/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
01-1
10092582_0001
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
White
Homogeneous
01-2
10092582_0002
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
White
Homogeneous
02-1
10092582_0003
Floor Coating
None Detected 100% Other
Non-Fibrous
Ashed
Yellow
Homogeneous
02-2
10092582_0004
Floor Coating
None Detected 100% Other
Non-Fibrous
Ashed
Yellow
Homogeneous
03-1
10092582_0005
Drywall & Joint Compound
None Detected 100% Other
Non-Fibrous
Teased
White, Brown
Heterogeneous drywall:none detect; joint compound:none detect
03-2
10092582_0006
Drywall & Joint Compound
None Detected 100% Other
Non-Fibrous
Teased
White, Brown
Heterogeneous drywall:none detect; joint compound:none detect
04-1
10092582_0007
Block Coating
None Detected 100% Other
Non-Fibrous
Crushed, Dissolved
Black, White
Heterogeneous
04-2
10092582_0008
Block Coating
None Detected 100% Other
Non-Fibrous
Dissolved, Crushed
White, Black
Heterogeneous
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Byron Stroble (40) Jalen Moore (6)
Analyst Approved Signatory
Page 1 of 6P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10092582Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Date Amended:
Braxton Dawson Bailey Proctor
PLM
09/19/2025
Project: BEQ 703 Camp Lejune, NC Date Reported: 09/24/2025
10/06/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
04-3
10092582_0009
Block Coating
None Detected 100% Other
Non-Fibrous
Dissolved, Crushed
White, Black
Heterogeneous
04-4
10092582_0010
Block Coating
None Detected 100% Other
Non-Fibrous
Crushed, Dissolved
White, Black
Heterogeneous
04-5
10092582_0011
Block Coating
None Detected 100% Other
Non-Fibrous
Dissolved, Crushed
White, Black
Heterogeneous
04-6
10092582_0012
Block Coating
None Detected 100% Other
Non-Fibrous
Dissolved, Crushed
White, Black
Heterogeneous
04-7
10092582_0013
Block Coating
None Detected 100% Other
Non-Fibrous
Crushed, Dissolved
White, Black
Heterogeneous
05-1
10092582_0014
White Mastic
None Detected 100% Other
Non-Fibrous
Ashed
White
Homogeneous
05-2
10092582_0015
White Mastic
None Detected 100% Other
Non-Fibrous
Ashed
White
Homogeneous
06-1
10092582_0016
Ceiling Texture
None Detected 100% Other
Non-Fibrous
Teased
White
Homogeneous
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Byron Stroble (40) Jalen Moore (6)
Page 2 of 6P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10092582Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Date Amended:
Braxton Dawson Bailey Proctor
PLM
09/19/2025
Project: BEQ 703 Camp Lejune, NC Date Reported: 09/24/2025
10/06/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
06-2
10092582_0017
Ceiling Texture
None Detected 100% Other
Non-Fibrous
Teased
White
Homogeneous
06-3
10092582_0018
Ceiling Texture
None Detected 100% Other
Non-Fibrous
Teased
White
Homogeneous
06-4
10092582_0019
Ceiling Texture
None Detected 100% Other
Non-Fibrous
Teased
White
Homogeneous
06-5
10092582_0020
Ceiling Texture
None Detected 100% Other
Non-Fibrous
Teased
White
Homogeneous
06-6
10092582_0021
Ceiling Texture
None Detected 100% Other
Non-Fibrous
Teased
White
Homogeneous
06-7
10092582_0022
Ceiling Texture
None Detected 100% Other
Non-Fibrous
Ashed
White
Homogeneous
07-1
10092582_0023
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
White
Homogeneous
07-2
10092582_0024
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Byron Stroble (40) Jalen Moore (6)
Page 3 of 6P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10092582Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Date Amended:
Braxton Dawson Bailey Proctor
PLM
09/19/2025
Project: BEQ 703 Camp Lejune, NC Date Reported: 09/24/2025
10/06/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
08-1
10092582_0025
Ventilator Duct Sealant
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
08-2
10092582_0026
Ventilator Duct Sealant
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
09-1
10092582_0027
Vent Pipe Tar
None Detected 10% Cellulose 90% Other
Non-Fibrous
Dissolved
Black
Homogeneous
09-2
10092582_0028
Vent Pipe Tar
None Detected 10% Cellulose 90% Other
Non-Fibrous
Dissolved
Black
Homogeneous
10-1
10092582_0029
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
10-2
10092582_0030
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
11-1
10092582_0031
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
11-2
10092582_0032
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Byron Stroble (40) Jalen Moore (6)
Page 4 of 6P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10092582Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Date Amended:
Braxton Dawson Bailey Proctor
PLM
09/19/2025
Project: BEQ 703 Camp Lejune, NC Date Reported: 09/24/2025
10/06/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
12-1
10092582_0033
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
12-2
10092582_0034
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
13-1
10092582_0035
Drywall & Joint Compound
None Detected 10% Cellulose 90% Other
Non-Fibrous
Teased
Brown, White
Heterogeneous drywall: none detected, joint compound: none detected
13-2
10092582_0036
Drywall & Joint Compound
None Detected 10% Cellulose 90% Other
Non-Fibrous
Teased
Brown, White
Heterogeneous drywall: none detected, joint compound: none detected
14-1
10092582_0037
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
14-2
10092582_0038
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous
15-1
10092582_0039
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray, Black
Homogeneous
15-2
10092582_0040
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Gray, Black
Homogeneous
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Byron Stroble (40) Jalen Moore (6)
Page 5 of 6P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10092582Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Date Amended:
Braxton Dawson Bailey Proctor
PLM
09/19/2025
Project: BEQ 703 Camp Lejune, NC Date Reported: 09/24/2025
10/06/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
16-1
10092582_0041
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Silver
Homogeneous
16-2
10092582_0042
Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Silver
Homogeneous
17-1 - A
10092582_0043
Backer Board & Stucco
None Detected 100% Other
Non-Fibrous
Crushed
Gray, White
Heterogeneous stucco
17-1 - B
10092582_0045
Backer Board & Stucco
None Detected 10% Fiber Glass 90% Other
Non-Fibrous
Crushed
Gray
Homogeneous backer board
17-2 - A
10092582_0044
Backer Board & Stucco
None Detected 100% Other
Non-Fibrous
Crushed
Gray, White
Heterogeneous stucco
17-2 - B
10092582_0046
Backer Board & Stucco
None Detected 10% Fiber Glass 90% Other
Non-Fibrous
Crushed
Gray
Homogeneous backer board
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Byron Stroble (40) Jalen Moore (6)
Page 6 of 6P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Client: ECS Southeast, LLC •tnatructJotq:
Contact: Braxton Dawson Use Column "B" for your contact Info Addreu: 6714 Netherlands Drive
Wilmington, NC 28405 Phone: 910-899-1289 To See an Example Click th8 Fu: 910-686-9666 bottom Example Tab.
Email: bda~n@ecslimlt~.!.Qm cc: t111rQ!;!or<al!!!,~limtt~.g2m Emer ump/es betwNn •,cc• and•»• Project: BEQ 703 Begin S.mplu with a "<< "above the first umple
Camp Lejune, NC and end with a "»>" below the last ump/a.
Client Notas: Only Eifler your data on the first sheet "Sheat1 • Data Sampled: 9/18/2025 0:00 P.O.#. 49-26366 Nole: Data t end Data 2 8f8 optional Date Submitted: 9/18/2025 0:00 fields that do nol show up on th8 ofllclal report, however they will be Included Analysls: PLM Bulk w/ Positive Stop In the eleclronlc data returned to you TumArounclTlme: 72-hrTAT to f&cl/tate ,,,,.., r&lnt_,.tion of th8 ,.,,,.,,, data.
Sam-Number INotas ~ Descrl....,.n 01-1 Caulk 01-2 Caulk 02-1 Floor Coatino 02-2 Floor Caatino 03-1 Drvwall & Joint Com= •nd 03-2 Drvwall & Joint Com=•nd 04-1 Block Caatina 04-2 Block Coatinn 04-3 Block Coatino 04-4 Block Coatina 04-5 Block Coatina 04-6 Block Coatina 04-7 Block Coatina 05-1 White Mastic 05-2 Whtte Mastic 06-1 Ceilino Texture 06-2 Ceilino Texture 06-3 Ceilino Texture 06-4 Ceilina Texture 06-5 Ceil inn Texture 06-6 Ceilino Texture 06-7 Ceilino Texture 07-1 Caulk 07-2 Caulk 08-1 Ventilator Duct Sealant 08-2 Ventilator Duct Sealant 09-1 Vent Pioe Tar 09-2 Vent Pioe Tar 10-1 Caulk 10-2 Caulk 11-1 Caulk 11-2 Caulk 12-1 Caulk 12-2 Caulk 13-1 Drywall & Joint Comnnund 13-2 Drvwall & Joint Com=•nd 14-1 Caulk 14-2 Caulk 15-1 Caulk 15-2 Caulk 16-1 Caulk 16-2 Caulk 17-1 Backer Board & Stucco 17-2 Backer Board & Stucco
I
Braxton B. Dawson
Sclentlfk:
Analytk:a/ OPi Institute , 4604 Dundas Drive Greensboro, NC 27407 Phone: 336.292.3888
Fax: 336.292.33J3 Email: labOsallab.com llocatlon
Interior Masonry Joints Interior Masonrv Joints Throuohout Interior Throuohout Interior Barrack Wino Ceilinos Barrack Wino Ceilinos Interior Walls Interior Walls Interior Walls Interior Walls Interior Walls Interior Walls Interior Walls HVAC • Mechanical Rooms · On Fil HVAC • Mechanical Rooms· On Fil Barrack Winos Barrack Winos Barrack Winos Barrack Winos Barrack Wings Barrack Winos Barrack Winos Interior Windows Interior Windows Attic Attic Attic Attic Exterior Doors Exterior Doors Exterior Windows Exterior Windows Exterior Masonrv Joints Exterior Masonrv Joints 1st Floor Common Areas 1st Floor Common Areas Mechanical Buildina G713 - Doors Mechanical Buildino G713 • Doors HVAC - Mechanical Buildina G713 HVAC • Mechanical Building G713 Aluminum Jacketed TSI - HVAC G7 Aluminum Jacketed TSI • HVAC G7 Exterior Soffit Exterior Soffit
Accepted d Rejected O
Fa:
lfflall:
cc:
l'nljeot:
CIIIIINolN:
o.......-.
P.O.t.
0.. .......... :
01-1 01-2 02-1 02-2 03-1 03-2 04-1 04-2 04-3 04-4 04-5 04-6 04-7 05-1 05-2 06-1 06-2 06-3 06-4 06-5 ..
06-6 06-7 07-1 07-2 08-1 08-2 09-1 09-2
,tt-1 - ,t0.2 - 11-1
1t1-,2 ~ -
12.1 _
12..0 i 13-1 13-2 14-1 14-2 15-1 15-2 16-1 16-2 17-1 17-2
I
Brutono-, 714 Ne1heflands Drive
Wilmington, NC 28405 910-899-1289 91o-886-9866 bdawson@ecslimited.com bproctor@ecslimited.com
BEQ703
C8mp Lejwle, NC
911812025 0:00 9-26366
9118/2025 0:00
PlM Buk w/ Poslllwl Stop 72-ttTAT
Samples were missing on previous shipment .,..mp1es were missing on previous shlnmant :;ampMtS were missing on previous ahinmAnt Samples were missing on previous shloment 581np1GS were missing on previous ahloment Samples were mlaslng on previous ahlnmant u.. Counn 'B"•)'IU'onac:f t'IAI
To SN_,~ Clr:lr Ille boaan,~Tm.
...,....,_,,__. ._.Md"»" ....,.._..._. •• cc•.,_. ... ...,...,.
MdMdwMe "» Oll/yEnllr)Gl'detlon,_lht,,_,"SIINt1.
,..: Defll 1 end Defll 2 - opllonel ffllde fhet do not lhow .., on Ille allr:IIII ,wpa,t. ,__l,ey .. belnduded In,,,. Mdnlnlc .,...,.,,,,.., ,oc, '° --- alflle da.
Ceulk :a.•
Floor Coellna Floor LOllllflD
.,.,,...., & Joint r ., Drvwall&Jolntf',nmnnund Block Coeting Block Coetina Block Coetina Block Coatina Block Coetina Block Coatina Block Coatina White Mastic White Mastic CeiHna Texture Celtina Texture Celllna Texture CeiUna Texture Calllna Texture Celtina Texture Caillna Texture Caulk Caulk Vantllator Duct Sealant Ventilator Duct Sealant Vent Ptpe Tar Vent Ptoe Tar
Caulk
Caulk
Caulk
Caulk
Caulk
Caulk urvwall & Joint ·-urvwall & Joint ·- Caulk Caulk Caulk Caulk Caulk Caulk Backer Board & Stucco Backer Board & Stucco
4604 Dundas Drive Greensboro, NC 27407 Phone: 33f.ZtZ.3 ...
Fax: 33f.ZtZ.3313 Email: lab sallab.com
Interior Mnonry Joints Interior M~ Joints fhroualx>ut Interior fhroualx>ut Interior Bam,ck Wino Ceilings Bam,ck Wlna Ceilinas Interior Walls Interior Walls Interior Walls Interior Walls Interior Walls Interior Walls Interior Walls HVAC • Mechanical Rooms. On Fil HVAC • Mechanical Rooms • On Fil Bam,ck Winos Bam,ck Winos Bam,ckWlnas Barrack Winas Barrack Wings Barrack WI..,..
Bam,ck Winos Interior Windows Interior Windows Attic Attic Attic Attic
Exterior Doors
Exterior Doors
Exterior Windows
Exterior Windows
ExteriorMasonrvJolnts
Exterior Masonrv Joints 1st Floor Common Arees 1 at Floor Common Areas Mechanical Bulldino G713 • Doors Mechanical Bulldina G713 • Doors HVAC -Mechanical Buildlna G713 HVAC • Mechanical Bulldina G713 Aluminum Jacketed TSI • HVAC G7 Aluminum Jacketed TSI - HVAC G7 ExteriorSoffit Exterior Soffit
Accep ed
Rejccl~d dJ D
Received By l 0\1 • { {J\ ?JU(VI\
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10099362Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Braxton Dawson
PLM
01/05/2026
Project: G-703 Date Reported: 01/06/2026
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
1-1
10099362_0001
Damp Proofing
None Detected 20% Cellulose 80% Other
Non-Fibrous
Dissolved, Crushed
Black
Heterogeneous
1-2
10099362_0002
Damp Proofing
None Detected 20% Cellulose 80% Other
Non-Fibrous
Dissolved, Crushed
Black
Heterogeneous
2-1 - A
10099362_0003
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Dissolved, Crushed
Red
Homogeneous ceramic tile
2-1 - B
10099362_0009
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed
Gray
Homogeneous grout
2-1 - C
10099362_0010
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed
Off-white
Homogeneous mortar
2-2 - A
10099362_0004
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed, Dissolved
Red
Homogeneous ceramic tile
2-2 - B
10099362_0011
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed
Gray
Homogeneous grout
2-2 - C
10099362_0012
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed
Off-white
Homogeneous mortar
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Lachlan Krenz (16)
Page 1 of 2P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10099362Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Braxton Dawson
PLM
01/05/2026
Project: G-703 Date Reported: 01/06/2026
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
3-1
10099362_0005
Damp Proofing
None Detected 20% Cellulose 80% Other
Non-Fibrous
Dissolved
Black
Homogeneous
3-2
10099362_0006
Damp Proofing
None Detected 20% Cellulose 80% Other
Non-Fibrous
Dissolved
Black
Homogeneous
4-1 - A
10099362_0007
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed, Dissolved
Red
Homogeneous ceramic tile
4-1 - B
10099362_0013
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed
Gray
Homogeneous grout
4-1 - C
10099362_0014
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed
Off-white
Homogeneous mortar
4-2 - A
10099362_0008
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed, Dissolved
Red
Homogeneous ceramic tile
4-2 - B
10099362_0015
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed
Gray
Homogeneous grout
4-2 - C
10099362_0016
Tile, Grout, Mortar
None Detected 100% Other
Non-Fibrous
Crushed
Off-white
Homogeneous mortar
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Lachlan Krenz (16)
Page 2 of 2P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Scientific Analytical Institute 4604 Dundas Dr. Greensboro, NC 27407
Phone: 336.292.3888 Fax: 336.292.3313 www.sailab.com lab@sailab.com
Company Contact Information -- -
Company: ECS Southeast. LLP Contact: Braxton Dawson
Address: 6714 Netherlands Drive Phone [XI : 910-899-1289
Wilmington , NC 28405 Fax 0 :
Email IX] :
bdawson@ecslimited.com
Billin2flnvoice Information Turn Around Times Company: 90Min. □ 48 Hours □ Contact: 3 Hours □ 72 Hours □ Address: 6 Hours □ 96 Hours □
12 Hours D 120 Hours D 24 Hours [3 144+Hours D
~j{"'~ ·
PO Number: Y'i- :;L0 5 (ul, Project Name/Number: {.::r"7D]
Lab Use Only l'"i'\ n OI 2J11'1 Lab Order ID: lill. vl \ --1Y V Client Code: ______ _
Asbestos Test Types PLM EPA 600/R-93/116 (PLM) Ji?J .. -------------------------------- Positive slop !;21 PLM Point Count 400 (PT4) □ PLM Point Count I 000 (PTM) □ PCM NIOSH 7400-A Rules (PCM) □ B Rules (PCB) □ TWA(PTA) □
TEM AHERA (AHE) □
TEM Level II (Lil) □
TEM NIOSH 7402 (TN!) □
TEM Bulk Qualitative (TBL) □ TEM Bulk Chatfield (TBS) □ TEM Bulk Quantitative (TBQ) □ TEM Wipe ASTM D6480-05 □ TEM Microvac ASTM D5755-02 □ TEM Water EPA 100.2 (TWl) □ Other: □
Volume/ Area Comments
Date/Time
Received by
Accepted t=te1ected cr
{f I (
I I
Total # of Samples
Date/Time
Page_\ of L
A-F.0 17 EXP: 12-1-13
Appendix IV: Lead Laboratory Analytical Results
Analysis for Lead Concentration in Paint Chips by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Lab Order ID:Attn: 10092583Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Braxton Dawson Bailey Proctor
PBP
09/19/2025
Project: BEQ G703 Camp Lejune, NC Date Reported: 09/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes
Concentration (ppm)
Concentration (% by weight)
Mass (g)
Reporting Limit (ppm)
PC-1
10092583_0001
Red Sprinkler Pipe <57 <0.0057%570.0698
PC-2
10092583_0002
Blue Metal Doors <57 <0.0057%570.0705
PC-3
10092583_0003
Blue Metal Door Frames <44 <0.0044%440.0912
PC-4
10092583_0004
Beige CMU Walls <71 <0.0071%710.0562
PC-5
10092583_0005
Beige Drywall Walls <52 <0.0052%520.0774
PC-6
10092583_0006
Gray CMU Walls <34 <0.0034%340.0475
PC-7
10092583_0007
Beige CMU Walls <73 <0.0073%730.0550
PC-8
10092583_0008
White CMU Walls <43 <0.0043%430.0939
Disclaimer: Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 50ml sample is 4µg Total Pb). All sample dried before preparation and analysis.
Mark Doki (23)
Page 1 of 3L-F-021 r17 2/13/2027 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888 by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Lab Order ID:Attn: 10092583Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Braxton Dawson Bailey Proctor
PBP
09/19/2025
Project: BEQ G703 Camp Lejune, NC Date Reported: 09/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes
Concentration (ppm)
Concentration (% by weight)
Mass (g)
Reporting Limit (ppm)
PC-9
10092583_0009
Brown Metal Double Doors <50. <0.0050%50.0.0802
PC-10
10092583_0010
Brown Metal Double Door Frames
<53 <0.0053%530.0750
PC-11
10092583_0011
White Metal Attic Hatch <46 <0.0046%460.0866
PC-12
10092583_0012
White Drywall Ceilings <38 <0.0038%380.1043
PC-13
10092583_0013
Tan CMU Walls <42 <0.0042%420.0957
PC-14
10092583_0014
White Gypsum Ceilings <39 <0.0039%390.1031
PC-15
10092583_0015
Brown Metal Doors <65 <0.0065%650.0615
PC-16
10092583_0016
Brown Metal Door Frames <61 <0.0061%610.0651
Disclaimer: Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .