This file is Appendix D of UFC 1-300-08, a Building Information Checklist template for collecting real property facility data for entry into federal real property databases.
The checklist serves as a standardized data collection instrument organized into five sections. Section 1 captures building dimensions and construction materials, including outside dimensions for the main building, wings, basement, attic, roof, and foundation, along with ceiling heights, door specifications, fire rating codes, and material types for structural components, exterior/interior walls, floors, and sub-floors. Section 2 documents utility connections and fuel data, specifying the number of pipes, diameters, and capacity for water, gas, sewer, storm sewer, steam, condensate, and communications systems, as well as energy system details including heating, air conditioning, hot water, steam, and electrical specifications with phase, voltage, wire size, and connected load information. Section 3 addresses building systems with nomenclature and quantities of fire protection systems, security systems, heating systems, air conditioning equipment, electrical generators, and hot water systems. Section 4 catalogs installed building equipment classified as real property, such as evaporative coolers, water heaters, exhaust fans, plumbing fixtures, heating plants, dehumidifiers, elevators, and theater seating. Section 5 provides a checklist for associated utilities and structures to be documented on DD Form 1354, including electrical distribution lines, transformers, gas mains, sanitary/storm sewer systems, water distribution, fire hydrants, curbs, driveways, roadways, parking areas, fencing, sidewalks, and telephone infrastructure. The template is designed for architect-engineer firms to provide data electronically in formats such as XML or GIS-compatible formats.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0013.pdf | ||
| Amend 0012.pdf | ||
| Amend 0011.pdf | ||
| Amend 0010.pdf | ||
| Amend 0009.pdf | ||
| Amend 0008.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0004.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| RFP 250010.pdf | ||
| 25-0051 SID.pdf | ||
| 25-0051 BOD.pdf | ||
| 25-0010 BOD.pdf | ||
| 25-0010 APPD.pdf | ||
| N4008525B0051 DWG_Signed.pdf | ||
| N4008525B0051 Specs.pdf | ||
| N4008525B0010 Specs.pdf | ||
| 25-0010 SID.pdf | ||
| 25-0051 GEO.pdf | ||
| 25-0010 DM for Repair BEQ 702.pdf | ||
| 25-0010 Lead and Asbestos Report.pdf | ||
| 25-0051 DM.pdf | ||
| 25-0010 GEO.pdf | ||
| 25-0051 Asbestos and Lead Report.pdf | ||
| N4008525B0010 DWG_Signed.pdf |
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UFC 1-300-08
30 JUNE 2004Const. Contract No:
APPENDIX D
BUILDING INFORMATION CHECKLIST
Use Appendix D as a checklist of required information to be entered into the real property database. Provide this information for each Real Property Facility listed on the DD Form 1354 in a format that allows easy data entry into the real property system. Normally this information is provided by the A/E electronically, often in XML format or GIS compatible format.
BUILDING IDENTIFICATION for this 5-Part CHECKLIST
Facility Number Building Name Number of Floors Gross SF Net SF
1. Building Dimensions and Construction Materials
Building Outside Dimensions Length (LF) Width (LF)
Main Building
Wings
Offsets
Basement
Attic
Porches, covered
Roof
Foundation
Other Building Data Feet
Ceiling Height Main Bldg.
Ceiling Height Basement
Door Height
Door Width
Code
Fire Rating Code
Construction Materials Type Principal Structural Material
Secondary Structural Material
Exterior Wall Material
Interior Wall Material
Floor Surface Material
Sub-Floor Material
D-1
30 JUNE 2004
Additional Construction Materials Type
Foundation Form Pile or Foundation Material
Foundation
Roof Type Roof Material
Roof Support
Roof Deck
Roof Surface
Construction Materials (Pavements) Type
Surface Course Materials
Base Course Materials
2. Utility Connections, Information and Fuel Data
Utility Connections
Number of Pipes
Diameter of each pipe
Capacity of all inlet pipes
Available or Connected?
(Yes/No)
Water
Gas
Sewer Pipe
Storm Sewer Pipe
Steam
Condensate
Communications
System Energy Type
Source Location
Fuel Description Air Circulation
Heating
Air Conditioning
Hot Water
Steam
Electrical
Electric Phase Voltage Wire Size
Connected Load - AMPS
Connected Load - KVA
D-2
3. Building Systems
Nomenclature UM Amount of UM Description
Fire Protection System
Closed Head Auto Sprinkler HD
Open Head Deluge System HD
Auto Fire Detection System HD
Manual Fire Alarm System EA
CO2 Fire System EA
Foam Fire System EA
Other Fire System EA
Halon 1301 Fire System EA
Security System
Security Alarm System EA
Heating System
Heating Plant MB
Storage Tank for Heating Fuel GA
Air Conditioning System
Central A/C Plant TN
Electrical System
Emergency Electrical Power Generator KW/KVA
Storage Tank for Generator Fuel GA
Hot Water
D-3
4. Installed Building Equipment (Real Property)
Item Size/Quantity Units Model Description
Evaporative Coolers CFM
Hot Water Heater GA
Exhaust Fan CFM
Wash Basin EACH
Water Closet EACH
Urinal EACH
Utility Sink EACH
Refrigerated Drinking Fountain EACH
Heating Plant Under 750 MB/Hr MB
Forced Air Heating BTU
Other Heating BTU
Dehumidifiers GPM
Elevators LBS & PN
Theater-type Seats, bolted to floor PN
Other (SPECIFY)
D-4
5. Checklist for Associated Utilities and Structures to be specifically listed as an item on DD Form 1354, column 10, if part of the project.
Nomenclature UM Amount of UM Cost Comments
Primary Elect. Distr. Line OH LF
Transformers KVA
Power Poles EA
Secondary Elect. Distr. Line OH LF
Exterior Street Lighting or Parking Area Lights EA
Gas Mains LF
Septic Systems KG
Sanitary Sewer LF
Water Distr. Mains LF
Fire Hydrants EA
Curbs & Gutters LF
Driveway SY
Roadway SY
Vehicle Parking SY
Storm Drain LF
Fence, Security LF
Fence, Interior LF
Sidewalk SY
Transformer Vault (four or more transformers) SF
Telephone Duct LF
Telephone Pole LF
Bridge Abutment EA
D5
Untitled
30 JUNE 2004
APPENDIX D
BUILDING INFORMATION CHECKLIST
Use Appendix D as a checklist of required information to be entered into the real property database. Provide this information for each Real Property Facility listed on the DD Form 1354 in a format that allows easy data entry into the real property system. Normally this information is provided by the A/E electronically, often in XML format or GIS compatible format.
BUILDING IDENTIFICATION for this 5-Part CHECKLIST Facility Number Building Name Number of Floors Gross SF Net SF
1. Building Dimensions and Construction Materials Building Outside Dimensions Length (LF) Width (LF) Main Building Wings Offsets Basement Attic Porches, covered Roof Foundation Other Building Data Feet Ceiling Height Main Bldg.
Ceiling Height Basement Door Height Door Width Code Fire Rating Code Construction Materials Type Principal Structural Material Secondary Structural Material Exterior Wall Material Interior Wall Material Floor Surface Material Sub-Floor Material D-1
UFC 1-300-08
30 JUNE 2004
Additional Construction Materials Type Foundation Form Pile or Foundation Material Foundation Roof Type Roof Material Roof Support Roof Deck Roof Surface Construction Materials (Pavements) Type Surface Course Materials Base Course Materials
2. Utility Connections, Information and Fuel Data Utility Connections Number of Pipes Diameter of each pipe Capacity of all inlet pipes Available or Connected?
(Yes/No) Water Gas Sewer Pipe Storm Sewer Pipe Steam Condensate Communications System Energy Type Source Location Fuel Description Air Circulation Heating Air Conditioning Hot Water Steam Electrical Electric Phase Voltage Wire Size Connected Load - AMPS Connected Load - KVA D-2
UFC 1-300-08
30 JUNE 2004
3. Building Systems Nomenclature
UM
Amount of UM Description Fire Protection System Closed Head Auto Sprinkler
HD
Open Head Deluge System
HD
Auto Fire Detection System
HD
Manual Fire Alarm System
EA
CO2 Fire System
EA
Foam Fire System
EA
Other Fire System
EA
Halon 1301 Fire System
EA
Security System Security Alarm System
EA
Heating System Heating Plant
MB
Storage Tank for Heating Fuel
GA
Air Conditioning System Central A/C Plant
TN
Electrical System Emergency Electrical Power Generator
KW/KVA
Storage Tank for Generator Fuel
GA
Hot Water D-3
UFC 1-300-08
30 JUNE 2004
4. Installed Building Equipment (Real Property) Item Size/Quantity Units Model Description Evaporative Coolers
CFM
Hot Water Heater
GA
Exhaust Fan
CFM
Wash Basin
EACH
Water Closet
EACH
Urinal
EACH
Utility Sink
EACH
Refrigerated Drinking Fountain
EACH
Heating Plant Under 750 MB/Hr
MB
Forced Air Heating
BTU
Other Heating
BTU
Dehumidifiers
GPM
Elevators
LBS & PN
Theater-type Seats, bolted to floor
PN
Other (SPECIFY) D-4
UFC 1-300-08
30 JUNE 2004
5. Checklist for Associated Utilities and Structures to be specifically listed as an item on DD Form 1354, column 10, if part of the project.
Nomenclature
UM
Amount of UM Cost Comments Primary Elect. Distr. Line OH
LF
Transformers
KVA
Power Poles
EA
Secondary Elect. Distr. Line OH
LF
Exterior Street Lighting or Parking Area Lights
EA
Gas Mains
LF
Septic Systems
KG
Sanitary Sewer
LF
Water Distr. Mains
LF
Fire Hydrants
EA
Curbs & Gutters
LF
Driveway
SY
Roadway
SY
Vehicle Parking
SY
Storm Drain
LF
Fence, Security
LF
Fence, Interior
LF
Sidewalk
SY
Transformer Vault (four or more transformers)
SF
Telephone Duct
LF
Telephone Pole
LF
Bridge Abutment
EA
D5 8.0.1291.1.339988.308172 Print Form
Const. Contract No:
N40085-25-B-0051
APPENDIX D
BUILDING INFORMATION CHECKLIST
Use Appendix D as a checklist of required information to be entered into the real property database. Provide this information for each Real Property Facility listed on the DD Form 1354 in a format that allows easy data entry into the real property system. Normally this information is provided by the A/E electronically, often in XML format or
GIS compatible format.
BUILDING IDENTIFICATION for this 5-Part CHECKLIST
Facility
Number Building Name
Number of Floors Gross SF Net SF G703 G703 37707 27230
1. Building Dimensions and Construction Materials
Building Outside
Dimensions Length (LF) Width (LF) Main Building 108'-8" 196'-4" Wings Offsets Basement Attic 108'-8" 196'-4" Porches, covered Roof 116'-8" 204'-4" Foundation Other Building Data Feet Ceiling Height Main Bldg.
10'-8" Ceiling Height Basement Door Height 7'-0" Door Width 3'-0" Code Fire Rating Code Type IIB Sprinklered Construction Materials Type Principal Structural Material Cast-in-Place concrete Secondary Structural Material CMU/Brick infill Exterior Wall Material CMU + brick cavity wall Interior Wall Material CMU painted Floor Surface Material vinyl plank, porcelain tile, resinous Sub-Floor Material Concrete slab & cast-in-place concrete D-1
Additional Construction Materials Type Foundation Form Pile or Foundation Material Foundation Existing concrete grade beam Concrete Roof Type Roof Material Roof Support Wood Roof Deck Roof Surface aluminum standing seam
Construction Materials
(Pavements) Type Surface Course Materials Asphalt Base Course Materials ABC Stone Base
2. Utility Connections, Information and Fuel Data
Utility
Connections
Number of
Pipes
Diameter of each pipe
Capacity of all inlet pipes
Available or
Connected?
(Yes/No) Water 4"
180 GPM
Yes Gas 2"
2,155 CFH
Yes Sewer Pipe 6"
530.5 F.U.'s
Yes Storm Sewer Pipe 12" Yes Steam Condensate Communications System
Energy
Type
Source
Location
Fuel
Description Air Circulation Heating Gas Mech Bldg Natural Gas Yes Air Conditioning Yes Chiller Yard Yes Yes Hot Water Steam Electrical UG Electrical
PMT
Electric Phase Voltage
Wire
Size
Connected
Load - AMPS
Connected
Load - KVA
BEQ
4 runs, 4-350 MCM 1198.8 431.9 Mech Building 2 runs, 4-#3/0 306.9 255.2 D-2
3. Building Systems Nomenclature
UM
Amount of UM Description Fire Protection System Closed Head Auto Sprinkler
HD
38,000-sf Wet pipe sprinkler system Open Head Deluge System
HD
N/A Auto Fire Detection System
HD
1 System Automatic fire detection system comprised of smoke detectors and waterflow switches Manual Fire Alarm System
EA
1 System Manual fire detection system comprised of manual pull stations CO2 Fire System
EA
N/A Foam Fire System
EA
N/A Other Fire System
EA
N/A Halon 1301 Fire System
EA
N/A Security System Security Alarm System
EA
Heating System Heating Plant
MB
1197 MBH
3 NG Condensing Boiler System Storage Tank for Heating Fuel
GA
Air Conditioning System Central A/C Plant
TN
Air-cooled Scroll Chiller Electrical System
Emergency Electrical Power
Generator
KW/KVA
n/a Storage Tank for Generator Fuel
GA
n/a Hot Water D-3
4. Installed Building Equipment (Real Property) Item Size/Quantity Units Model Description Evaporative Coolers
CFM
Hot Water Heater
GA
Exhaust Fan
CFM
Wash Basin
EACH
Stainless Wall mounted Water Closet
EACH
Stainless Floor mounted, flush valve Urinal
EACH
Stainless Wall mounted, flush valve Utility Sink
EACH
Terrazzo Floor mounted mop basin Refrigerated Drinking Fountain
EACH
Stainless Wall mounted
Heating Plant Under
750 MB/Hr 3 Boilers
MB
399,000 BTU's each Forced Air Heating 1,328,200
BTU
DOAS, UH, AHU
Other Heating
BTU
Dehumidifiers 70 Pints/Day / 6
GPM
(6) Dehumidifiers Elevators
LBS & PN
Theater-type Seats, bolted to floor
PN
Other (SPECIFY) D-4
5. Checklist for Associated Utilities and Structures to be specifically listed as an item on DD
Form 1354, column 10, if part of the project.
Nomenclature
UM
Amount of UM Cost Comments Primary Elect. Distr. Line OH
LF
n/a Transformers
KVA
(1) 300 kVA and (1) 225 kVA Power Poles
EA
n/a Secondary Elect. Distr. Line OH
LF
n/a
Exterior Street Lighting or Parking
Area Lights
EA
n/a Gas Mains
LF
Septic Systems
KG
Sanitary Sewer
LF
6" Building Service Water Distr. Mains
LF
4" Building Service Fire Hydrants
EA
Curbs & Gutters
LF
Driveway
SY
Mechanical Building Drive, Dumpster Area Roadway
SY
Vehicle Parking
SY
1,775 Storm Drain
LF
Roof Gutter Leader System Fence, Security
LF
At Mechanical Yard Fence, Interior
LF
Sidewalk
SY
Transformer Vault (four or more transformers)
SF
n/a Telephone Duct
LF
n/a Telephone Pole
LF
Bridge Abutment
EA
D5
| PrintButton1: |
| TextField1: |
N40085-25-B-0051 TextField2:
G703 TextField2:
G703 TextField2:
TextField2:
37707 TextField2:
27230 TextField3:
108'-8" TextField3:
196'-4" TextField3:
TextField3:
TextField3:
TextField3:
TextField3:
TextField3:
TextField3:
108'-8" TextField3:
196'-4" TextField3:
TextField3:
TextField3:
116'-8" TextField3:
204'-4" TextField3:
TextField3:
TextField5:
10'-8" TextField5:
TextField5:
7'-0" TextField5:
3'-0" TextField5:
Type IIB Sprinklered TextField4:
Cast-in-Place concrete TextField4:
CMU/Brick infill TextField4:
CMU + brick cavity wall TextField4:
CMU painted TextField4:
vinyl plank, porcelain tile, resinous TextField4:
Concrete slab & cast-in-place concrete TextField6:
Existing concrete grade beam TextField6:
Concrete TextField7:
Wood TextField7:
TextField7:
TextField7:
TextField7:
TextField7:
aluminum standing seam TextField8:
Asphalt TextField8:
ABC Stone Base TextField9:
TextField9:
4" TextField9:
180 GPM
TextField9:
Yes TextField9:
TextField9:
2" TextField9:
2,155 CFH
TextField9:
Yes TextField9:
TextField9:
6" TextField9:
530.5 F.U.'s
TextField9:
Yes TextField9:
TextField9:
12" TextField9:
TextField9:
Yes TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField10:
Gas TextField10:
Mech Bldg TextField10:
Natural Gas TextField10:
Yes TextField10:
Yes TextField10:
Chiller Yard TextField10:
Yes TextField10:
Yes TextField10:
TextField10:
TextField10:
TextField10:
TextField10:
TextField10:
TextField10:
TextField10:
TextField10:
UG Electrical TextField10:
PMT
TextField10:
TextField10:
TextField10:
TextField10:
TextField10:
TextField10:
TextField11:
BEQ
TextField11:
TextField11:
TextField11:
4 runs, 4-350 MCM TextField11:
1198.8 TextField11:
431.9 TextField11:
Mech Building TextField11:
TextField11:
TextField11:
2 runs, 4-#3/0 TextField11:
306.9 TextField11:
255.2 TextField11:
TextField11:
TextField11:
TextField11:
TextField11:
TextField11:
TextField12:
38,000-sf TextField12:
Wet pipe sprinkler system TextField12:
N/A TextField12:
TextField12:
1 System TextField12:
Automatic fire detection system comprised of smoke detectors and waterflow switches TextField12:
1 System TextField12:
Manual fire detection system comprised of manual pull stations TextField12:
N/A TextField12:
TextField12:
N/A TextField12:
TextField12:
N/A TextField12:
TextField12:
N/A TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
1197 MBH
TextField12:
3 NG Condensing Boiler System TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
Air-cooled Scroll Chiller TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
n/a TextField12:
TextField12:
n/a TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
Stainless TextField13:
Wall mounted TextField13:
TextField13:
Stainless TextField13:
Floor mounted, flush valve TextField13:
TextField13:
Stainless TextField13:
Wall mounted, flush valve TextField13:
TextField13:
Terrazzo TextField13:
Floor mounted mop basin TextField13:
TextField13:
Stainless TextField13:
Wall mounted TextField13:
3 Boilers TextField13:
TextField13:
399,000 BTU's each TextField13:
1,328,200 TextField13:
TextField13:
DOAS, UH, AHU
TextField13:
TextField13:
TextField13:
TextField13:
70 Pints/Day / 6 TextField13:
TextField13:
(6) Dehumidifiers TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField15:
n/a TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
(1) 300 kVA and (1) 225 kVA TextField15:
n/a TextField15:
TextField15:
TextField15:
n/a TextField15:
TextField15:
TextField15:
n/a TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
6" Building Service TextField15:
TextField15:
TextField15:
4" Building Service TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
Mechanical Building Drive, Dumpster Area TextField15:
TextField15:
TextField15:
TextField15:
1,775 TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
Roof Gutter Leader System TextField15:
TextField15:
TextField15:
At Mechanical Yard TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
n/a TextField15:
TextField15:
TextField15:
n/a TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField14:
TextField14:
TextField14:
TextField14:
TextField14:
TextField14:
TextField14:
TextField14:
File details come from the government source that posted it. Updated .