This is a Structural Interior Design Package submittal for the repair of Bachelor Enlisted Quarters (BEQ) Building FC555 at U.S. Marine Corps Base Camp Lejeune, North Carolina. The sealed final submittal is dated May 2026 and was prepared by Within Interior Design in coordination with MBF Architects and other design disciplines.
The document outlines comprehensive interior finish specifications across flooring, partitions, and specialty elements. Flooring finishes include luxury vinyl tile (LVT-1, Mannington Crisscross Zoom Charcoal) for sleeping quarters; epoxy resinous flooring (RES-1, Sherwin Williams Deco Quartz Caterpillar) for common lounge areas; quarry tile (T-4, Daltile Arid Flash) for kitchen spaces; and color-body porcelain tile (T-1, Crossville Shade 2.0 Thunder) for bathrooms. Laundry spaces receive resinous epoxy flooring (RES-1), while exterior walkways utilize non-slip epoxy coating (RES-2, Interstate Traction-N-More). Interior partitions are finished with textured acrylic paint (PNT-1, Benjamin Moore Classic Grey for primary walls; PNT-2, Benjamin Moore River Reflections for accents), with vinyl wall graphics in lounge areas. Casework incorporates plastic laminate finishes (PLAM-1, Formica Blackened Legno) with solid surface countertops (SS-1, Corian Neutral Aggregate). Signage systems utilize 2/90 Sign Systems components with high-contrast, accessible design standards including tactile lettering and Grade 2 braille. Design compliance addresses Navy & Marine Corps standards (FC 1-300-09N, FC 4-721-10N), DoD Building Code (UFC 1-200-01), High Performance and Sustainable Building Requirements (UFC 1-200-02), and Lodging Facilities standards (UFC 4-720-01), with emphasis on durability, sustainability through long-life products and low-VOC finishes, and accessibility requirements. Review meetings conducted at 50%, 95%, and final stages documented coordinated corrections to room designations, floor finishes, casework configurations, and signage details, with a digital final submittal deadline of February 12, 2026.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0008.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0004.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| N4008525B0009 Specs.pdf | ||
| 25-0009 BOD.pdf | ||
| 25-0009 Asbestos and Lead Survey.pdf | ||
| 25-0009 APPD.pdf | ||
| 25-0009 ACM Report.pdf | ||
| RFP 250009.pdf | ||
| N4008525B0009 DWGs.pdf | ||
| 25-0009 DM.pdf | ||
| 25-0009 GEO.pdf | ||
| 25-0009 FPDA.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INTERIOR DESIGN
within
Repair BEQ FC555 U.S. Marine Corps Base, Camp Lejeune, NC
Structural Interior Design Package Sealed Final Submittal May 2026
Repair BEQ FC555 U.S. Marine Corps Base, Camp Lejeune, NC Structural Interior Design Package interior design within
Table of Contents
1. Point of Contact List
2. Narrative of Interior Design Objectives
3. Meeting Minutes
4. Finish Plans & Schedules
5. Finish Boards
Structural Interior Design Package interior design within
Point of Contact List
Base Architectural Supervisor Cathy Martin, Department of the Navy Public Works Division Marine Corps Base Camp Lejeune, NC
(910) 451-0394 catherine.martin@usmc.mil
A&E Project Manager John Schmied, AIA, LEED AP, BD+C MBF Architects 317-C Pollock Street New Bern, NC 28560
(252) 637-6373 schmied@mbfarchitects.com
A&E Interior Designer Jamie Kissel, NCIDQ Within Interior Design 1008 Granby Street Norfolk, VA 23510
(757) 224-0489 jkissel@withindesigns.com
Structural Interior Design Package interior design within
SID Narrative This Basis of Design Narrative outlines the proposed Structural Interior Design requirements for Repairs to BEQ FC555 at MCB Camp Lejeune, NC. The interior finishes are the most exposed interior elements in a building and must be durable to withstand the daily traffic and demands of the environment. Structural finishes in accordance with the following guidelines will provide longevity and timeless aesthetics without compromising the functional integrity of the facility.
FLOORING
Luxury vinyl tile flooring will be used in sleeping quarters, common lounge areas will receive epoxy resinous flooring. Laundry spaces will receive resinous epoxy flooring while bathrooms will receive color-body porcelain tile flooring. Kitchen will recieve quarry tile flooring.
PARTITIONS
Interior partitions will be painted with a textured acrylic coating. Vinyl wall graphics will be utilized in lounge areas to provide visual variety.
SPECIALTIES
Interior Signage will include identification, directional and informational systems utilizing permanent and changeable signage systems.
SUSTAINABILITY
Products with a long-life span have been selected to reduce the need for replacing materials.
Products with recycled content have also been selected. Finishes with low VOC content and bio-based materials are given higher priority.
INTERIOR DESIGN CRITERIA
Interior Design work will comply with the latest edition of the following codes and standards:
FC 1-300-09N Navy & Marine Corps Design Requirements, 07-09-2021 FC 4-721-10N Navy & Marine Corps Unaccompanied Housing, 05-19-2022 UFC 1-200-01 DoD Building Code, 02-26-2024 UFC 1-200-02 High Performance and Sustainable Building Requirements, 06-01-2022 UFC 3-120-01 Design: Sign Standards, 02-01-2023 UFC 3-120-10 Interior Design, 06-15-2021 UFC 3-190-06 Protective Coatings and Paints, 03-01-2021 UFC 4-720-01 Lodging Facilities, 02-13-2012
Structural Interior Design Package interior design
Meeting Minutes interior design
1 | P a g e
1008 Granby Street | Norfolk, VA 23510 | 757.224.0489
MEETING MINUTES
Project: Repair BEQ FC555 Meeting: 50% Review Meeting Date: October 30th, 2025 Location: Microsoft Teams Meeting
PROJECT TEAM IN ATTENDANCE:
Architecture MBF Architects (252) 637-6373 Civil Engineer Avolis Engineering (252) 633-0068 Structural Engineer Kaydos-Daniels Engineers (919) 828-4966 Mechanical/Electrical/Plumbing Crenshaw Consulting (919) 871-1070 Fire Protection Jensen Hughes (757) 213-6856 Cost Estimating Aiken Cost Consultants (864) 232-9342 Geotechnical ECS Southeast (919) 861-9910 Interior Design Within Interior Design (757) 224-0489
Below are the items that were addressed at the 50% Review Meeting.
50% REVIEW COMMENTS
REVIEWER: KELLY ROOT
Item #3 I-111 – I-113: Bachelor housing is requesting we keep existing room numbers. They've had trouble with signage.
Response: Concur. Coordinate with MBF.
Item #37 I-101: I’m thinking we make the offices Resinous Flooring. Throughs?
Response: Concur. Floor finish in offices will be updated to Resinous Flooring RES-1.
Item #38 I-102: Rm 239 is telecom. Rm 238 is linen.
Response: Concur. Room name will be corrected.
Item #39 I-103: Rm 339 is office. Rm 338 is linen.
Response: Concur. Room name will be corrected.
Item #40 I-101 – I-103: Coordinate washer/dryer counts with arch
Response: Concur. Linked model will be updated to match Arch drawings.
Item #41 I-101 – I-103: Can you add the exterior walkway finish called out on these plans?
Response: Concur. RES-2 will be added to the exterior walkways on the finish plans.
2 | P a g e
Item #42 A2,C2/I-201: Can we put all drawers on this cabinet where section marker is taken?
Response: Concur. Base cabinet will be changed to 4 drawer cabinet.
Item #43 A3,C3/I-201: Add (5) 8-12" shelves on plan north wall. Make closet rod and shelf full width
Response: Concur. Closet casework will be revised.
Item #44 C1/I-201: Add medicine cabinet(s).
Response: Concur. WID will coordinate with MBF to update mirrors to include recessed medicine cabinet.
Item #45 A1,C1/I-201: Add corner cabinet and extend upper cabinets to the same extent of lower cabinets. Max size for fridge/microwave unit is 72" so I don't think we can fit cabinets above that.
Response: Concur. Casework will be revised.
Item #46 D4/I-301: Add additional shelf.
Response: Concur. Shelf will be added.
Item #47 I-201 & I-301: Continue SS to bottom of cabinets, not just a backsplash as kitchenette.
Response: Concur. Casework will be revised to show full-height solid surface backsplash.
Item #48 I-301: Bathroom vanity should have integral SS bowl.
Response: Concur. Section drawing will be revised to show integral SS bowl.
REVIEWER: FRANKLIN ETIENNE
Item #5 I-402: Room 239 is COMM (not linen storage).
Response: Concur. Room name will be revised.
Item #6 I-601: Room 239 is COMM (Not Linen Storage).
Response: Concur. Room name will be revised.
Item #7 I-601: Flooring should be SC-1 (Not RES-1).
Response: Concur. Floor finish will be revised.
ACTION ITEMS
1. 95% Submittal due to government on 12/22/25.
Meeting: 95% Review Meeting Date: January 22nd, 2026 Location: 1005 Michael Rd, Camp Lejeune, NC
PROJECT TEAM IN ATTENDANCE:
Architecture MBF Architects (252) 637-6373 Civil Engineer Avolis Engineering (252) 633-0068 Structural Engineer Kaydos-Daniels Engineers (919) 828-4966 Mechanical/Electrical/Plumbing Crenshaw Consulting (919) 871-1070 Fire Protection Jensen Hughes (757) 213-6856 Cost Estimating Aiken Cost Consultants (864) 232-9342 Geotechnical ECS Southeast (919) 861-9910 Interior Design Within Interior Design (757) 224-0489
Below are the items that were addressed at the 95% Review Meeting.
95% REVIEW COMMENTS
REVIEWER: TREVOR STREETER
Item #12 I-501: Reflect the accessible sign design, layout, and fonts as additional typical signage details.
Response: Concur. Details regarding high contrast/non-glare finishes, sans serif fonts, signage clarity and domed braille have been added to the SIGNAGE NOTES.
Item #16 I-101: Concrete flooring in the vending/corridor area changes to Resilient flooring in the kitchen and is not "technically" combustible-proof.
Response: Concur. Kitchen flooring will be changed to quarry tile.
Item #17 Is there a reason why sleeping rooms 131 and 315 have signage pointing to S7? When all of the other sleeping rooms have S1? Ensure all rooms have the correct exterior signage and that the overall count of these signs is reflected on the signage schedule on I-111, I- 112, and I-113.
Response: Concur. These signs have been corrected.
Item #25 I-202: Label grout joint thickness (A1, A3).
Response: Concur. Grout thickness note will be added.
REVIEWER: CATHY MARTIN
Item #28 I-Sheets: The drawing package is missing the sleeping room furniture sheets, please add.
Response: FF&E & Furniture Plans are not included in the Interiors scope – MBF confirmed furniture layouts will be covered in Arch drawings.
Item #29 I-103: Replace room tag for room 339 to reflect OFFICE in lieu of COMM room.
Response: Concur. Room name will be corrected.
Item #35 I-301: Bathroom vanity should have integral ss bowl. (from 50% comments)
Response: Concur. Section drawing will be revised with added notation.
Item #36 I-601: Add mechanical buildings to room finish schedule
Response: Concur. Mechanical Building will be added.
ADDITIONAL NOTES
• Cathy Martin will provide a revised FF&E layout to MBF that will accommodate the PTAC and bump out at corner rooms.
ACTION ITEMS
1. Digital Final Submittal due to government on 2/12/26.
Meeting: Final Review Meeting Date: March 24th, 2026 Location: 1005 Michael Rd, Camp Lejeune, NC
PROJECT TEAM IN ATTENDANCE:
Architecture MBF Architects (252) 637-6373 Civil Engineer Avolis Engineering (252) 633-0068 Structural Engineer Kaydos-Daniels Engineers (919) 828-4966 Mechanical/Electrical/Plumbing Crenshaw Consulting (919) 871-1070 Fire Protection Jensen Hughes (757) 213-6856 Cost Estimating Aiken Cost Consultants (864) 232-9342 Geotechnical ECS Southeast (919) 861-9910 Interior Design Within Interior Design (757) 224-0489
Below are the items that were addressed at the 95% Review Meeting.
FINAL REVIEW COMMENTS
REVIEWER: CATHY MARTIN
Item #17 I-601: Add mechanical buildings to room finish schedule
Response: Concur. Mechanical Building will be added.
Item #18 I-Sheets: The drawing package is missing the sleeping room furniture sheets, please add.
Response: FF&E & Furniture Plans are not included in the Interiors scope – MBF confirmed furniture layouts will be covered in Arch drawings.
Item #19 I-103: Replace room tag for room 339 to reflect OFFICE in lieu of COMM room.
Response: Concur. Room name will be corrected.
REVIEWER: TREVOR STREETER
Item #20 I-112/113: Should sleeping rooms 213, 215, 313, and 315 have signage reflect the other sleeping rooms (S1) instead of (S7)?
Response: Concur. These signs have been corrected
Item #21 I-202: Label grout joint thickness (A1, A3).
Response: Concur. Grout thickness to be added
Item #22 I-501: Reflect the accessible sign design, layout, and fonts as additional typical signage details.
Response: Avolis - Will provide Hc parking signage,route.
Concur. Details regarding high contrast/non-glare finishes, sans serif fonts, signage clarity and domed braille have been added to the SIGNAGE NOTES.
Item #23 I-101/102/103: If fixtures are shown in one room, it should be reflected throughout. Ensure towel bars, toilet paper dispensers, etc... are either all shown in the respective drawing sets, or are hidden until notated later. I'd hate for the wrong amount of something to be ordered or not factored into installation because it wasn't visually portrayed when it should have been, or hidden and given its own detail/enlarged sheet later-on. (A small note to tack on, women's toilet 140 and 147 is like this, where the hand dryer/paper towel dispenser is in one, but not another.)
Response: Updated. (MBFA)
Item #24 I-111: Can we have Janitor Room 141 swing into the laundry room 133? Might make access easier for the maintenance staff, rather than trapsing through an admin office during the middle of the day.
Response: MBF will make adjustments.
REVIEWER: DOUG STULTZ
Item #90 Spec Section 10 14 00.20: Related to Previous Comment GI10x floor Plans: (General Note 5: Please spell out the fire rating barrier marking per IBC section 703.5.) Prime Contractor and their sub-tier painting contractor need these requirements within a spec section. Insert the fire/smoke barrier signage requirements of IBC §703.5 into Spec Section 10 14 00.20 Interior Signage of if more appropriate Spec Section 09 90 00 Paints and Coatings
Response: Within will make adjustment. Verbiage provided by Doug will be added to the interior signage spec.
Structural Interior Design Package interior design
Finish Plans & Schedules
FLOOR FINISH KEY
LVT-1
T-1
RES-1
SC-1
RES-2
T-4
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
CLERK'S
OFFICE
ADMINISTRATIVE
OFFICE
NO. 1
ADMINISTRATIVE
OFFICE
NO. 2
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
X.O.
OFFICE
C.O.
OFFICE
STORAGE
1ST SGT'S
OFFICE
143 MEN'S
TOILET
MECH.
WOMEN'S
TOILET
MECH
JAN
LAUNDRY
LAUNDRY
CORR.
JAN
OFFICE
ADMINISTRATIVE
OFFICE NO.
JAN
WOMEN'S
TOILET
KITCHEN
X.O.
OFFICE
1ST SGT'S
OFFICE
ADMINISTRATIVE
OFFICE NO.
CLERK'S
OFFICE
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
ELECTRICAL
VENDING
MECH.MECH. MECH.
I-401 B1
I-401 B5
SLEEPING
ROOM
***HATCH PATTERN DOES NOT INDICATE DIRECTION OR METHOD OF FLOORING INSTALLATION.
Fi le
P at h:
Pr in t D at e:
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
1008 GRANBY
STREET
NORFOLK, VA 23510
757.224.0489
05-25-0009
CHRIS MAAS
W :\2
FC
BE
Q R en ov at io n C
L\ R ev it\
B
FC
W
ID
R
.rv t
5/
/2
4:
:4
PM
I-101
APG
JDK
JDK REPAIR BEQ FC555
FIRST FLOOR FINISH PLAN
60042659 : N40085-25-B-0009
SCALE: 1/8" = 1'-0"A1 1ST FLOOR FINISH PLAN
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO
CONVEY COLOR, PATTERN, TEXTURE AND SALIENT
CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER
INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF
PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED
AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF
RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND
APPROVED BY THE CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING
LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO
ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT
SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF
A WALL.
FINISH NOTES
J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO
BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE
PAINTED (PNT-6).
K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
M. ALL INTERIOR WOOD DOORS TO BE (WD-1).
N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING
SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH
(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).
SEE DETAIL A3/1-202.
O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO
MATCH EXISTING CONDITIONS.
P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH
SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE
TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.
Q. SEE I-601 FOR FINISH LEGEND.
FINISH NOTES
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,
AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.
PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE
CENTERED UNDER DOOR.
H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE
METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS
WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE
WHERE APPLICABLE FOR A COMPLETE INSTALLATION.
I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
I G
IV R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR
DE
SI
GN
ENo.
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECH.
LAUNDRY
LOUNGE
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
JAN
ELECTRICAL
LINEN
STORAGE
COMM
CORR.
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECH. MECH.
WG-1
WG-1
***HATCH PATTERN DOES NOT INDICATE DIRECTION OR METHOD OF FLOORING INSTALLATION.
FLOOR FINISH KEY
LVT-1
T-1
RES-1
SC-1
RES-2
T-4
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0009
CHRIS MAAS
W :\2
FC
BE
Q R en ov at io n C
L\ R ev it\
B
FC
W
ID
R
.rv t
5/ 8/
:4
2:
P M
I-102
APG
JDK
JDK REPAIR BEQ FC555
SECOND FLOOR FINISH PLAN
60042660 : N40085-25-B-0009
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
SCALE: 1/8" = 1'-0"A1 2ND FLOOR FINISH PLAN
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO
CONVEY COLOR, PATTERN, TEXTURE AND SALIENT
CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER
INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF
PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED
AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF
RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND
APPROVED BY THE CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING
LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO
ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT
SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF
A WALL.
FINISH NOTES
J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO
BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE
PAINTED (PNT-6).
K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
M. ALL INTERIOR WOOD DOORS TO BE (WD-1).
N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING
SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH
(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).
SEE DETAIL A3/1-202.
O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO
MATCH EXISTING CONDITIONS.
P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH
SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE
TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.
Q. SEE I-601 FOR FINISH LEGEND.
FINISH NOTES
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,
AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.
PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE
CENTERED UNDER DOOR.
H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE
METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS
WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE
WHERE APPLICABLE FOR A COMPLETE INSTALLATION.
I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
I G
IV R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR
DE
SI
E No.
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECH.
LOUNGE
LAUNDRY
JAN
ELECTRICAL
LINEN
STORAGE
CORR.
OFFICE
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECH. MECH.
WG-1
WG-1
***HATCH PATTERN DOES NOT INDICATE DIRECTION OR METHOD OF FLOORING INSTALLATION.
FLOOR FINISH KEY
LVT-1
T-1
RES-1
SC-1
RES-2
T-4
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0009
CHRIS MAAS
W :\2
FC
BE
Q R en ov at io n C
L\ R ev it\
B
FC
W
ID
R
.rv t
5/ 8/
:4
2:
P M
I-103
APG
JDK
JDK REPAIR BEQ FC555
THIRD FLOOR FINISH PLAN
60042661 : N40085-25-B-0009
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
SCALE: 1/8" = 1'-0"A1 3RD FLOOR FINISH PLAN
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO
CONVEY COLOR, PATTERN, TEXTURE AND SALIENT
CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER
INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF
PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED
AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF
RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND
APPROVED BY THE CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING
LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO
ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT
SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF
A WALL.
FINISH NOTES
J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO
BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE
PAINTED (PNT-6).
K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
M. ALL INTERIOR WOOD DOORS TO BE (WD-1).
N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING
SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH
(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).
SEE DETAIL A3/1-202.
O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO
MATCH EXISTING CONDITIONS.
P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH
SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE
TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.
Q. SEE I-601 FOR FINISH LEGEND.
FINISH NOTES
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,
AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.
PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE
CENTERED UNDER DOOR.
H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE
METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS
WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE
WHERE APPLICABLE FOR A COMPLETE INSTALLATION.
I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
I G
IV R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR
DE
SI
MECH.MECH. MECH. MECH.
S1 S1 S1 S1 S1 S7 S1 S1 S1 S1 S1
S1S1S1S1S1S1S1S1S1S1 S2 S2
S6S6
S4S4
S8 S8
S7
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
CLERK'S
OFFICE
ADMINISTRATIVE
OFFICE
NO. 1
ADMINISTRATIVE
OFFICE
NO. 2
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
X.O.
OFFICE
C.O.
OFFICE
STORAGE
MEN'S
TOILET
WOMEN'S
TOILET
MECH
JAN
LAUNDRY
LAUNDRY
CORR.
JAN
OFFICE
ADMINISTRATIVE
OFFICE NO.
JAN
WOMEN'S
TOILET
KITCHEN
X.O.
OFFICE
1ST SGT'S
OFFICE
CLERK'S
OFFICE
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
ELECTRICAL
VENDING
SLEEPING
ROOM
ADMINISTRATIVE
OFFICE NO.
1ST SGT'S
OFFICE
I-402 B1
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0009
CHRIS MAAS
W :\2
FC
BE
Q R en ov at io n C
L\ R ev it\
B
FC
W
ID
R
.rv t
5/ 8/
:4
2:
P M
I-111
APG
JDK
JDK REPAIR BEQ FC555
FIRST FLOOR SIGNAGE PLAN
60042662 : N40085-25-B-0009
SIGNAGE SCHEDULE
TYPE DESCRIPTION QTY
S1 SLEEPING QUARTERS IDENTIFICATION SIGN 80
S2 PERMANENT ROOM IDENTIFICATION SIGN 37
S3 NON-PERMANENT ROOM IDENTIFICATION SIGN 3
S4 STAIRWELL LEVEL INDICATOR 9
S5M MENS RESTROOM IDENTIFICATION SIGN 1
S5W WOMENS RESTROOM IDENTIFICATION SIGN 2
S6 SMALL DIRECTIONAL SIGN 11
S7 EXTERIOR ROOM SIGN 13
S8 STAIRWELL IDENTIFICATION SIGN 10
SIGNAGE NOTES
A. ALL SIGNAGE TO COMPLY WITH UFC 3 120 01.
B. ALL SIGN TYPES, TEXT WORDING, AND ROOM NUMBERS TO BE VERIFIED
WITH END USER AND REVIEWED BY NAVFAC INTERIOR DESIGNER PRIOR TO
FABRICATION.
C. ALL GRADE 2 BRAILLE TO BE TACTILE RAISED 0.8 MM FROM THE SURFACE
WITH ROUNDED DOTS.
D. SIGNS MUST USE HIGH CONTRAST, NON-GLARE FINISHES. CHARACTERS
MUST BE UPPER CASE AND USE SANS SERIF FONTS.
E. SIGNS MUST INCLUDE CLEAR VISUAL ELEMENTS FOR INDIVIDUALS WITH
LOW VISION, BLINDNESS AND COGNITIVE DISABILITIES.
F. SIGNS THAT MOUNT TO GLASS MUST INCLUDE AN EQUALLY SIZED BLANK
SIGN PANEL ALIGNED TO OPPOSITE SIDE OF THE GLASS.
G. REFER TO SHEET I-501 FOR SIGNAGE DETAILS.
H. REFER TO SHEET I-601 FINISH LEGEND FOR SIGNAGE FINISHES.
I. MOUNTING OF SIGNAGE SYSTEM MUST INCLUDE SURFACE MOUNTING
WITH SCREW-ON APPLICATION FOR INTERIOR WALLS.
J. SEE ELEVATION I-501 FOR MOUNTING HEIGHT OF ACRYLIC SIGNAGE.
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
SCALE: 1/8" = 1'-0"A1 1ST FLOOR SIGNAGE PLAN
I G
IV R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR
DE
SI
MECH. MECH.
S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1
S1S1S1S1S1S1S1S1S1S1
S6S6
S4S4
S1 S1
S8 S8
S2 S2S1S1S1 S1
S1S1S1
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECH.
LAUNDRY
LOUNGE
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
JAN
ELECTRICAL
LINEN
STORAGE
COMM
CORR.
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
I-402 B5
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0009
CHRIS MAAS
W :\2
FC
BE
Q R en ov at io n C
L\ R ev it\
B
FC
W
ID
R
.rv t
5/ 8/
:4
2:
P M
I-112
APG
JDK
JDK REPAIR BEQ FC555
SECOND FLOOR SIGNAGE PLAN
60042663 : N40085-25-B-0009
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
SCALE: 1/8" = 1'-0"A1 2ND FLOOR SIGNAGE PLAN
SIGNAGE SCHEDULE
TYPE DESCRIPTION QTY
S1 SLEEPING QUARTERS IDENTIFICATION SIGN 80
S2 PERMANENT ROOM IDENTIFICATION SIGN 37
S3 NON-PERMANENT ROOM IDENTIFICATION SIGN 3
S4 STAIRWELL LEVEL INDICATOR 9
S5M MENS RESTROOM IDENTIFICATION SIGN 1
S5W WOMENS RESTROOM IDENTIFICATION SIGN 2
S6 SMALL DIRECTIONAL SIGN 11
S7 EXTERIOR ROOM SIGN 13
S8 STAIRWELL IDENTIFICATION SIGN 10
SIGNAGE NOTES
A. ALL SIGNAGE TO COMPLY WITH UFC 3 120 01.
B. ALL SIGN TYPES, TEXT WORDING, AND ROOM NUMBERS TO BE VERIFIED
WITH END USER AND REVIEWED BY NAVFAC INTERIOR DESIGNER PRIOR TO
FABRICATION.
C. ALL GRADE 2 BRAILLE TO BE TACTILE RAISED 0.8 MM FROM THE SURFACE
WITH ROUNDED DOTS.
D. SIGNS MUST USE HIGH CONTRAST, NON-GLARE FINISHES. CHARACTERS
MUST BE UPPER CASE AND USE SANS SERIF FONTS.
E. SIGNS MUST INCLUDE CLEAR VISUAL ELEMENTS FOR INDIVIDUALS WITH
LOW VISION, BLINDNESS AND COGNITIVE DISABILITIES.
F. SIGNS THAT MOUNT TO GLASS MUST INCLUDE AN EQUALLY SIZED BLANK
SIGN PANEL ALIGNED TO OPPOSITE SIDE OF THE GLASS.
G. REFER TO SHEET I-501 FOR SIGNAGE DETAILS.
H. REFER TO SHEET I-601 FINISH LEGEND FOR SIGNAGE FINISHES.
I. MOUNTING OF SIGNAGE SYSTEM MUST INCLUDE SURFACE MOUNTING
WITH SCREW-ON APPLICATION FOR INTERIOR WALLS.
J. SEE ELEVATION I-501 FOR MOUNTING HEIGHT OF ACRYLIC SIGNAGE.
I G
IV R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR
DE
SI
MECH. MECH.
S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1
S1S1S1S1S1S1S1S1S1S1
S6S6
S4S4
S1 S1
S8 S8
S2 S2S1S1S1 S1
S1S1S1
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECH.
LAUNDRY
LOUNGE
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
JAN
ELECTRICAL
LINEN
STORAGE
OFFICE
CORR.
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
MECHANICAL
SLEEPING
ROOM
SLEEPING
ROOM
SLEEPING
ROOM
I-402 B5
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0009
CHRIS MAAS
W :\2
FC
BE
Q R en ov at io n C
L\ R ev it\
B
FC
W
ID
R
.rv t
5/ 8/
:4
2:
P M
I-113
APG
JDK
JDK REPAIR BEQ FC555
THIRD FLOOR SIGNAGE PLAN
60042664 : N40085-25-B-0009
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
SCALE: 1/8" = 1'-0"A1 3RD FLOOR SIGNAGE PLAN
SIGNAGE SCHEDULE
TYPE DESCRIPTION QTY
S1 SLEEPING QUARTERS IDENTIFICATION SIGN 80
S2 PERMANENT ROOM IDENTIFICATION SIGN 37
S3 NON-PERMANENT ROOM IDENTIFICATION SIGN 3
S4 STAIRWELL LEVEL INDICATOR 9
S5M MENS RESTROOM IDENTIFICATION SIGN 1
S5W WOMENS RESTROOM IDENTIFICATION SIGN 2
S6 SMALL DIRECTIONAL SIGN 11
S7 EXTERIOR ROOM SIGN 13
S8 STAIRWELL IDENTIFICATION SIGN 10
SIGNAGE NOTES
A. ALL SIGNAGE TO COMPLY WITH UFC 3 120 01.
B. ALL SIGN TYPES, TEXT WORDING, AND ROOM NUMBERS TO BE VERIFIED
WITH END USER AND REVIEWED BY NAVFAC INTERIOR DESIGNER PRIOR TO
FABRICATION.
C. ALL GRADE 2 BRAILLE TO BE TACTILE RAISED 0.8 MM FROM THE SURFACE
WITH ROUNDED DOTS.
D. SIGNS MUST USE HIGH CONTRAST, NON-GLARE FINISHES. CHARACTERS
MUST BE UPPER CASE AND USE SANS SERIF FONTS.
E. SIGNS MUST INCLUDE CLEAR VISUAL ELEMENTS FOR INDIVIDUALS WITH
LOW VISION, BLINDNESS AND COGNITIVE DISABILITIES.
F. SIGNS THAT MOUNT TO GLASS MUST INCLUDE AN EQUALLY SIZED BLANK
SIGN PANEL ALIGNED TO OPPOSITE SIDE OF THE GLASS.
G. REFER TO SHEET I-501 FOR SIGNAGE DETAILS.
H. REFER TO SHEET I-601 FINISH LEGEND FOR SIGNAGE FINISHES.
I. MOUNTING OF SIGNAGE SYSTEM MUST INCLUDE SURFACE MOUNTING
WITH SCREW-ON APPLICATION FOR INTERIOR WALLS.
J. SEE ELEVATION I-501 FOR MOUNTING HEIGHT OF ACRYLIC SIGNAGE.
I G
IV R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR
DE
SI
D1 I-301
_______ A1 I-301
D3 I-301
SS-1
PLAM-1
FILLER STRIPS
PLAM-1
CABINETS
RB-1
TOE KICK
PLAM-1
CABINETS
SINKS CENTERED
ON CASEWORK
PLAM-1
FILLER STRIP
PNT-1
1" 28" 2"
24"1"30"1"
1" 26"
ANGLED
12" 15"
A2 I-301
D4 I-301
SS-1
PLAM-1
CABINETS
RB-1
TOE KICK
GFGI MICRO-
FRIDGE UNIT
PNT-1
PLAM-1
CABINETS
SCRIBE TO
CEILING
24" 2" 14"
FIELD VERIFY
25"
15"
ANGLED
12" 12"
A4 I-301
36" 12"
48"
3/4" PLYWOOD SHELF WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
1"X6" HARDWOOD CLEAT,
CONTINUOUS 3 SIDES
CLOSET ROD AS SPECIFIED
SECURE CASEWORK TO
WALL WITH MASONARY
ANCHOR , 10" O.C.
3/4" PLYWOOD SHEVES WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
RB-1
WALL BASE
A3 I-301
12" 36"
48"
3/4" PLYWOOD SHELF WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
1"X6" HARDWOOD CLEAT,
CONTINUOUS 3 SIDES
CLOSET ROD AS SPECIFIED
SECURE CASEWORK TO
WALL WITH MASONARY
ANCHOR , 10" O.C.
3/4" PLYWOOD SHELVES WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
RB-1
WALL BASE
A2 I-301
D4 I-301
SS-1
PLAM-1
CABINETS
RB-1
TOE KICK
GFGI MICRO-
FRIDGE UNIT
PNT-1
PLAM-1
CABINETS
FIELD VERIFY
25" 14" 2" 24"
12"
ANGLED
12" 15"
1"30"1"
SS-1
PLAM-1
FILLER STRIPS
PLAM-1
CABINETS
RB-1
TOE KICK
PLAM-1
CABINETS
SINKS CENTERED
ON CASEWORK
PLAM-1
FILLER STRIP
MIRRORED
CABINET
SS-1
PNT-1
CP-1
CABINET PULLS
24" 2" 28" 1"
26"
ANGLED
12"15"
D3 I-301
A1 I-301
_______ D1 I-301
30"18"
3/4" PLYWOOD SHELF WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
1"X6" HARDWOOD CLEAT,
CONTINUOUS 3 SIDES
CLOSET ROD AS SPECIFIED
SECURE CASEWORK TO
WALL WITH MASONARY
ANCHOR , 10" O.C.
3/4" PLYWOOD SHELVES WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
RB-1
WALL BASE
A3 I-301
48"
30" 18"
3/4" PLYWOOD SHELF WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
1"X6" HARDWOOD CLEAT,
CONTINUOUS 3 SIDES
CLOSET ROD AS SPECIFIED
SECURE CASEWORK TO
WALL WITH MASONARY
ANCHOR , 10" O.C.
3/4" PLYWOOD SHELVES WITH
3/4"X1-1/2" HARDWOOD
NOSING. STAIN
RB-1
WALL BASE
A3 I-301
48"
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0009
CHRIS MAAS
W :\2
FC
BE
Q R en ov at io n C
L\ R ev it\
B
FC
W
ID
R
.rv t
5/ 8/
:4
2:
P M
I-201
APG
JDK
JDK REPAIR BEQ FC555
INTERIOR ELEVATIONS
60042665 : N40085-25-B-0009
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO
CONVEY COLOR, PATTERN, TEXTURE AND SALIENT
CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER
INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF
PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED
AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF
RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND
APPROVED BY THE CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING
LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO
ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT
SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF
A WALL.
FINISH NOTES
J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO
BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE
PAINTED (PNT-6).
K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
M. ALL INTERIOR WOOD DOORS TO BE (WD-1).
N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING
SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH
(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).
SEE DETAIL A3/1-202.
O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO
MATCH EXISTING CONDITIONS.
P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH
SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE
TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.
Q. SEE I-601 FOR FINISH LEGEND.
CASEWORK NOTES
1. CASEWORK CONSTRUCTION AS INDICATED IN THE
DOCUMENTS MUST BE IN ACCORDANCE WITH A.W.I. QUALITY
STANDARDS FOR FLUSH OVERLAY CONSTRUCTION.
SEMI-EXPOSED SURFACES TO BE CONSTRUCTED USING
CUSTOM GRADE STANDARDS
2. ALL CASEWORK MUST BE IN COMPLIANCE WITH UFGS
SECTION 06 41 16.0 AND SECTION 06 61 1.
3. ALL COUNTERTOP AND BACK/SIDE SPLASHES TO BE SOLID
SURFACE (SS-1). BACK/SIDE SPLASHES ARE ONLY TO BE
APPLIED AT WALLS WITHOUT FULL HEIGHT SPLASH OR TILE.
4. ALL BASE CABINETS, WALL CABINETS, APRONS AND
SHROUDS WILL BE PLASTIC LAMINATE (PLAM-1).
5. ALL BASE CABINET TOE KICKS WILL BE RUBBER BASE (RB-1).
6. SEE SHEET I-601 FOR FINISH LEGEND.
SCALE: 3/4" = 1'-0"C1 TYP. BATHROOM VANITY & KITCHENETTE
0' 1' 2' 3' 3/4" =1'-0"
GRAPHIC SCALE:
SCALE: 3/4" = 1'-0"C2 TYP. KITCHENETTE
SCALE: 3/4" = 1'-0"C3 TYP. CLOSET ROD
FINISH NOTES
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,
AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.
PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE
CENTERED UNDER DOOR.
H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE
METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS
WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE
WHERE APPLICABLE FOR A COMPLETE INSTALLATION.
I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
SCALE: 3/4" = 1'-0"A3 TYP. CLOSET ROD
SCALE: 3/4" = 1'-0"A2 TYP. KITCHENETTE
SCALE: 3/4" = 1'-0"A1 TYP. BATHROOM VANITY & KITCHENETTE
SCALE: 3/4" = 1'-0"C4 TYP. CLOSET CASEWORK
SCALE: 3/4" = 1'-0"A4 TYP. CLOSET CASEWORK
I G
IV R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR
DE
SI
36" 36" 36" 4" 24"
SS-1
PLAM-1
FILLER STRIP
PLAM-1
CABINETS
RB-1
TOE KICK
PLAM-1
CABINETS
SINK CENTERED
ON CASEWORK
CP-1
CABINET PULLS
36" 36" 36"
ANGLED
12" 15"
D3 I-301
_______ D4 I-301
D2 I-301
_______ A1 I-301
GFGI ICE
MACHINE
SS-1
PLAM-1
CABINETS
RB-1
TOE KICK
PLAM-1
CABINETS
PNT-1
CP-1
CABINET PULLS
GFGI
APPLIANCES
24" 4" 18" 18"
VERIFY W/ EQUIP.
30" 18" 18"
15"
ANGLED
12" 36" 30" 36"
CFCI
APPLIANCE
D4 I-301
_______ D3 I-301
A2 I-301
_______ D2 I-301
GFGI
APPLIANCE
C
O U
R
SE
S
C O
U R
SE
S
TO
C
EI
LI
N G
T-3
T-2
TS-5
T-2
B1 I-502
1/8" GROUT
THICKNESS
FRP-1
RB-2
PNT-1
C4 I-502
B3 I-502
TS-7
PNT-7
PNT-5
±7
STRINGER ACCENT PAINT (PNT-7) TO
REPLACE EXISTING PAINTED FINISH.
U P
TO
C
EI
LI
N G
FRP-1
RB-2C4
I-502
Fi le
P at h:
Pr in t D at e:
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
1008 GRANBY
STREET
NORFOLK, VA 23510
757.224.0489
05-25-0009
CHRIS MAAS
W :\2
FC
BE
Q R en ov at io n C
L\ R ev it\
B
FC
W
ID
R
.rv t
5/
/2
2:
:1
PM
I-202
APG
JDK
JDK REPAIR BEQ FC555
INTERIOR ELEVATIONS
60042666 : N40085-25-B-0009
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO
CONVEY COLOR, PATTERN, TEXTURE AND SALIENT
CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER
INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF
PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED
AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF
RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND
APPROVED BY THE CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING
LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO
ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT
SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF
A WALL.
FINISH NOTES
J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO
BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE
PAINTED (PNT-6).
K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
M. ALL INTERIOR WOOD DOORS TO BE (WD-1).
N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING
SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH
(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).
SEE DETAIL A3/1-202.
O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO
MATCH EXISTING CONDITIONS.
P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH
SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE
TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.
Q. SEE I-601 FOR FINISH LEGEND.
CASEWORK NOTES
1. CASEWORK CONSTRUCTION AS INDICATED IN THE
DOCUMENTS MUST BE IN ACCORDANCE WITH A.W.I. QUALITY
STANDARDS FOR FLUSH OVERLAY CONSTRUCTION.
SEMI-EXPOSED SURFACES TO BE CONSTRUCTED USING
CUSTOM GRADE STANDARDS
2. ALL CASEWORK MUST BE IN COMPLIANCE WITH UFGS
SECTION 06 41 16.0 AND SECTION 06 61 1.
3. ALL COUNTERTOP AND BACK/SIDE SPLASHES TO BE SOLID
SURFACE (SS-1). BACK/SIDE SPLASHES ARE ONLY TO BE
APPLIED AT WALLS WITHOUT FULL HEIGHT SPLASH OR TILE.
4. ALL BASE CABINETS, WALL CABINETS, APRONS AND
SHROUDS WILL BE PLASTIC LAMINATE (PLAM-1).
5. ALL BASE CABINET TOE KICKS WILL BE RUBBER BASE (RB-1).
6. SEE SHEET I-601 FOR FINISH LEGEND.
0' 1' 2' 3' 3/4" =1'-0"
GRAPHIC SCALE:
FINISH NOTES
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,
AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.
PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE
CENTERED UNDER DOOR.
H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE
METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS
WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE
WHERE APPLICABLE FOR A COMPLETE INSTALLATION.
I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
SCALE: 3/4" = 1'-0"C1 COMMON KITCHEN 116 ELEVATION
SCALE: 3/4" = 1'-0"C3 COMMON KITCHEN 116 ELEVATION
SCALE: 3/4" = 1'-0"A1 TYP. RESTROOM TILE ELEVATION
SCALE: 3/4" = 1'-0"A2 TYP. JANITOR FRP ELEVATION
SCALE: 1 1/2" = 1'-0"A4 STAIR STRINGER PAINT DETAIL
4"0' 1 1/2" =1'-0"
8" 1'-4"
SCALE: 3/4" = 1'-0"A3 TYP.DRYER CHASE ELEVATION
I G
IV R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR
DE
SI
ENo.
SOLID SURFACE
COUNTERTOP WITH
EASED EDGE
HPL OVER 3/4"
PLYWOOD ON ALL
EXPOSED SURFACES
24"
HPL
INTERIOR
1/
2"
1/ 2"
4"
3" 21"
STAINLESS STEEL
BAR PULL
RUBBER BASE
AT TOE KICK
FULL HEIGHT SOLID
SURFACE BACKSPLASH
24"
3/ 4"
4" 3/
4"
UNDERMOUNT
STAINLESS STEEL SINK
I-502 B4
HPL ADJUSTABLE
SHELVES W/ 1-1/4"
LINE BORE
3/4" X 1-1/2"
HARDWOOD NOSING.
STAIN
SECURE
CASEOWORK W/
MASONRY ANCHOR,
10" O.C.
18"
1/
2"
1/ 2"
1/
2"
1/ 2"
1/
2"
1/ 2"
1X6 PLYWOOD CLEAT,
CONTINUOUS 3 SIDES
CLOSET ROD AS
SPECIFIED
HPL FIXED SHELF W/ 3/4"
PLYWOOD SUBSTRATE
3/4" X 1-1/2"
HARDWOOD NOSING.
STAIN TO MATCH HPL.
6"
18"
1/
2"
15"
FULL OVERLAY
FLUSH DOOR
FINISHED IN HPL
W/ MATCHING PVC
EDGEBAND
1/4" CABINET BACK
HPL INTERIOR
15"
FULL OVERLAY
FLUSH DOOR
FINISHED IN HPL
W/ MATCHING PVC
EDGEBAND
1/4" CABINET BACK
3/4" HPL ADJUSTABLE
SHELVES
HPL INTERIOR
RECESSED STANDARDS
SOLID SURFACE
COUNTERTOP
1/4" DRAWER
BOTTOM - DADO INTO
DRAWER BACK &
FRONT
INTERIOR
DRAWER BOXES
FINISHED IN HPL
1/4" CABINET BACK
DRAWER FRONTS
FINISHED IN HPL
W/ MATCHING PVC
EDGEBAND
RUBBER BASE
AT TOE KICK
FULL EXTENSION
DRAWER SLIDES
3" 21"
24"
1/
2"
3/ 8"
3/
4"
1/ 8"
1/
2"
1/ 8"
1/
2"
1/ 8"
9" 4"
FULL HEIGHT SOLID
SURFACE BACKSPLASH
24"
SOLID SURFACE
COUNTERTOP WITH
EASED EDGE
HPL OVER 3/4"
PLYWOOD ON ALL
EXPOSED INTERIOR &
EXTERIOR SURFACES
24"
1/
2"
1/ 2"
4"
3" 21"
RUBBER BASE
AT TOE KICK
24"
3/ 4"
4" 3/
4"
INTERIOR DRAWER
BOX FINISHED IN HPL
FULL EXTENSION
DRAWER SLIDES
FULL HEIGHT SOLID
SURFACE BACKSPLASH
3/4" HPL ADJUSTABLE
SHELF
RECESSED STANDARDS
SOLID SURFACE
COUNTERTOP WITH
EASED EDGE
HPL OVER 3/4"
PLYWOOD ON ALL
EXPOSED SURFACES
24"
HPL
INTERIOR
1/
2"
1/ 2"
4"
3" 21"
STAINLESS STEEL
BAR PULL
RUBBER BASE
AT TOE KICK
4" INTEGRAL
BACKSPLASH (FULL
HEIGHT SPLASH AT
KITCHENETTE)
24"
3/ 4"
4" 3/
4"
INTEGRAL SOLID
SURFACE BOWL
I-502 B4
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0009
CHRIS MAAS
W :\2
FC
BE
Q R en ov at io n C
L\ R ev it\
B
FC
W
ID
R
.rv t
5/ 8/
:4
2:
P M
I-301
APG
JDK
JDK REPAIR BEQ FC555
CASEWORK SECTIONS
60042667 : N40085-25-B-0009
CASEWORK NOTES
1. CASEWORK CONSTRUCTION AS INDICATED IN THE
DOCUMENTS MUST BE IN ACCORDANCE WITH A.W.I. QUALITY
STANDARDS FOR FLUSH OVERLAY CONSTRUCTION.
SEMI-EXPOSED SURFACES TO BE CONSTRUCTED USING
CUSTOM GRADE STANDARDS
2. ALL CASEWORK MUST BE IN COMPLIANCE WITH UFGS
SECTION 06 41 16.0 AND SECTION 06 61 1.
3. ALL COUNTERTOP AND BACK/SIDE SPLASHES TO BE SOLID
SURFACE (SS-1). BACK/SIDE SPLASHES ARE ONLY TO BE
APPLIED AT WALLS WITHOUT FULL HEIGHT SPLASH OR TILE.
4. ALL BASE CABINETS, WALL CABINETS, APRONS AND
SHROUDS WILL BE PLASTIC LAMINATE (PLAM-1).
5. ALL BASE CABINET TOE KICKS WILL BE RUBBER BASE (RB-1).
6. SEE SHEET I-601 FOR FINISH LEGEND.
4"0' 1 1/2" =1'-0"
GRAPHIC SCALE:
8" 1'-4"
SCALE: 1 1/2" = 1'-0"A1 SECTION - SINK CABINET
SCALE: 1 1/2" = 1'-0"A3 SECTION - CLOSET SHELVING
SCALE: 1 1/2" = 1'-0"A4 SECTION - CLOSET HANGING ROD
SCALE: 1 1/2" = 1'-0"D3 SECTION - UPPER CABINET 18"H
SCALE: 1 1/2" = 1'-0"D4 SECTION - UPPER CABINET 30"H
SCALE: 1 1/2" = 1'-0"A2 SECTION - 4 DRAWER BASE CAB.
SCALE: 1 1/2" = 1'-0"D2 SECTION - DOOR/DRAWER BASE CAB.
SCALE: 1 1/2" = 1'-0"D1 SECTION - RESTROOM SINK CABINET
I G
IV R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR
DE
SI
FLOOR FINISH KEY
LVT-1
T-1
RES-1
SC-1
RES-2
T-4
***HATCH PATTERN DOES NOT INDICATE DIRECTION OR METHOD OF FLOORING INSTALLATION.
LAUNDRY
MECH
LAUNDRY
JAN
CORR.
VENDING
ELECTRICAL
JAN
WOMEN'S
TOILET
MECH.
KITCHEN
ADMINISTRATIVE
OFFICE NO.
ADMINISTRATIVE
OFFICE NO.
1ST SGT'S
OFFICE
X.O.
OFFICE
OFFICE
PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
ADMINISTRATIVE
OFFICE
NO. 1
ADMINISTRATIVE
OFFICE
NO. 2
WOMEN'S
TOILET
JAN
MECH.
STORAGE
MEN'S
TOILET
C.O.
OFFICE
X.O.
OFFICE
PNT-2
1ST SGT'S
OFFICE
PNT-2
I-202
C1
C3
PN
T-
2CLERK'S
OFFICE
CLERK'S
OFFICE
PN
T-
I-202A3 A3
I-201
C1
SLEEPING
ROOM
PN
T-
PN
T-
2 SLEEPING
ROOM
C2
I-201 A3I-201C3I-201C3 I-201 A3
I-201
A1
A2
C4 A4C4 A4
MECHACNICAL
BLDG.
EXISTING
MECH.
BLDG.
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY STREET
NORFOLK, VA 23510
757.224.0489
05-25-0009
CHRIS MAAS
W :\2
FC
BE
Q R en ov at io n C
L\ R ev it\
B
FC
W
ID
R
.rv t
5/ 8/
:4
2:
P M
I-401
APG
JDK
JDK REPAIR BEQ FC555
ENLARGED FINISH PLANS
60042668 : N40085-25-B-0009
2' 4' 8'0' 1/4" =1'-0"
GRAPHIC SCALE:
SCALE: 1/4" = 1'-0"B1 ENLARGED 1ST FLOOR COMMON AREA FINISH PLAN
SCALE: 1/4" = 1'-0"B5 ENLARGED SLEEPING ROOMS FINISH PLAN
FINISH NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO
CONVEY COLOR, PATTERN, TEXTURE AND SALIENT
CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER
INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF
PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED
AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF
RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND
APPROVED BY THE CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING
LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO
ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT
SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF
A WALL.
FINISH NOTES
J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO
BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE
PAINTED (PNT-6).
K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID
SURFACE (SS-3).
M. ALL INTERIOR WOOD DOORS TO BE (WD-1).
N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING
SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH
(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).
SEE DETAIL A3/1-202.
O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO
MATCH EXISTING CONDITIONS.
P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH
SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE
TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.
Q. SEE I-601 FOR FINISH LEGEND.
FINISH NOTES
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,
AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.
PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE
CENTERED UNDER DOOR.
H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE
METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS
WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE
WHERE APPLICABLE FOR A COMPLETE INSTALLATION.
I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE
EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY
RESINOUS FLOORING.
0' 2' 4' 6' 3/8" =1'-0"
SCALE: 1/4" = 1'-0"A1 ENLARGED MECHANICAL BLDG. 556A FINISH PLAN
SCALE: 1/4" = 1'-0"A2 ENLARGED MECHANICAL BLDG. 555A FINISH PLAN
I G
IV R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR
DE
SI
S6
S4
S6
S2
S2
S2
S2
S8
MECH
LAUNDRY
LAUNDRY
OFFICE
VENDING
ELECTRICAL
JAN
CORR.
S2
S2
S2
S7
S2
S2
ADMINISTRATIVE
OFFICE NO.
117 ADMINISTRATIVE
OFFICE NO.
WOMEN'S
TOILET
JAN
MECH.
KITCHEN
1ST SGT'S
OFFICE
X.O.
OFFICE
S3
X.O.
OFFICE
C.O.
OFFICE
STORAGE
MEN'S
TOILET
1ST SGT'S
OFFICE
ADMINISTRATIVE
OFFICE
NO. 1
ADMINISTRATIVE
OFFICE
NO. 2
JAN
WOMEN'S
TOILET
S3 S3
S2
S7 S7 S7 S7
S7
S2
S5W S5W
S5M
S2
MECH.
S8
S2
S6
S4
S8
S2
S2
S2
S2
S2
S2
S2
MECH.
LAUNDRY
JAN
ELECTRICAL
LINEN
STORAGE
COMM
CORR.
LOUNGE
S7
S2
S2
S6
S4
S8
S6
S2
S2
S2
S2
S2
S2
S7
S2
S2 S2
MECHACNICAL
BLDG.
S7
S7
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
M
A.
P.
STCETIHCRA
FB
BERN N.C.NEW
CERT. NO.
UTCETIHCRA
DERETSIG E R NOI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED:…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .