This is a Structural Interior Design Package submittal for the repair of Bachelor Enlisted Quarters (BEQ) Building FC555 at U.S. Marine Corps Base Camp Lejeune, North Carolina. The sealed final submittal is dated May 2026 and was prepared by Within Interior Design in coordination with MBF Architects and other design disciplines.

The document outlines comprehensive interior finish specifications across flooring, partitions, and specialty elements. Flooring finishes include luxury vinyl tile (LVT-1, Mannington Crisscross Zoom Charcoal) for sleeping quarters; epoxy resinous flooring (RES-1, Sherwin Williams Deco Quartz Caterpillar) for common lounge areas; quarry tile (T-4, Daltile Arid Flash) for kitchen spaces; and color-body porcelain tile (T-1, Crossville Shade 2.0 Thunder) for bathrooms. Laundry spaces receive resinous epoxy flooring (RES-1), while exterior walkways utilize non-slip epoxy coating (RES-2, Interstate Traction-N-More). Interior partitions are finished with textured acrylic paint (PNT-1, Benjamin Moore Classic Grey for primary walls; PNT-2, Benjamin Moore River Reflections for accents), with vinyl wall graphics in lounge areas. Casework incorporates plastic laminate finishes (PLAM-1, Formica Blackened Legno) with solid surface countertops (SS-1, Corian Neutral Aggregate). Signage systems utilize 2/90 Sign Systems components with high-contrast, accessible design standards including tactile lettering and Grade 2 braille. Design compliance addresses Navy & Marine Corps standards (FC 1-300-09N, FC 4-721-10N), DoD Building Code (UFC 1-200-01), High Performance and Sustainable Building Requirements (UFC 1-200-02), and Lodging Facilities standards (UFC 4-720-01), with emphasis on durability, sustainability through long-life products and low-VOC finishes, and accessibility requirements. Review meetings conducted at 50%, 95%, and final stages documented coordinated corrections to room designations, floor finishes, casework configurations, and signage details, with a digital final submittal deadline of February 12, 2026.

View the file

Other files

File Type Posted
Amend 0008.pdf PDF
Amend 0007.pdf PDF
Amend 0006.pdf PDF
Amend 0005.pdf PDF
Amend 0004.pdf PDF
Amend 0003.pdf PDF
Amend 0002.pdf PDF
Amend 0001.pdf PDF
N4008525B0009 Specs.pdf PDF
25-0009 BOD.pdf PDF
25-0009 Asbestos and Lead Survey.pdf PDF
25-0009 APPD.pdf PDF
25-0009 ACM Report.pdf PDF
RFP 250009.pdf PDF
N4008525B0009 DWGs.pdf PDF
25-0009 DM.pdf PDF
25-0009 GEO.pdf PDF
25-0009 FPDA.pdf PDF
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INTERIOR DESIGN

within

Repair BEQ FC555 U.S. Marine Corps Base, Camp Lejeune, NC

Structural Interior Design Package Sealed Final Submittal May 2026

Repair BEQ FC555 U.S. Marine Corps Base, Camp Lejeune, NC Structural Interior Design Package interior design within

Table of Contents

1. Point of Contact List

2. Narrative of Interior Design Objectives

3. Meeting Minutes

4. Finish Plans & Schedules

5. Finish Boards

Structural Interior Design Package interior design within

Point of Contact List

Base Architectural Supervisor Cathy Martin, Department of the Navy Public Works Division Marine Corps Base Camp Lejeune, NC

(910) 451-0394 catherine.martin@usmc.mil

A&E Project Manager John Schmied, AIA, LEED AP, BD+C MBF Architects 317-C Pollock Street New Bern, NC 28560

(252) 637-6373 schmied@mbfarchitects.com

A&E Interior Designer Jamie Kissel, NCIDQ Within Interior Design 1008 Granby Street Norfolk, VA 23510

(757) 224-0489 jkissel@withindesigns.com

Structural Interior Design Package interior design within

SID Narrative This Basis of Design Narrative outlines the proposed Structural Interior Design requirements for Repairs to BEQ FC555 at MCB Camp Lejeune, NC. The interior finishes are the most exposed interior elements in a building and must be durable to withstand the daily traffic and demands of the environment. Structural finishes in accordance with the following guidelines will provide longevity and timeless aesthetics without compromising the functional integrity of the facility.

FLOORING

Luxury vinyl tile flooring will be used in sleeping quarters, common lounge areas will receive epoxy resinous flooring. Laundry spaces will receive resinous epoxy flooring while bathrooms will receive color-body porcelain tile flooring. Kitchen will recieve quarry tile flooring.

PARTITIONS

Interior partitions will be painted with a textured acrylic coating. Vinyl wall graphics will be utilized in lounge areas to provide visual variety.

SPECIALTIES

Interior Signage will include identification, directional and informational systems utilizing permanent and changeable signage systems.

SUSTAINABILITY

Products with a long-life span have been selected to reduce the need for replacing materials.

Products with recycled content have also been selected. Finishes with low VOC content and bio-based materials are given higher priority.

INTERIOR DESIGN CRITERIA

Interior Design work will comply with the latest edition of the following codes and standards:

FC 1-300-09N Navy & Marine Corps Design Requirements, 07-09-2021 FC 4-721-10N Navy & Marine Corps Unaccompanied Housing, 05-19-2022 UFC 1-200-01 DoD Building Code, 02-26-2024 UFC 1-200-02 High Performance and Sustainable Building Requirements, 06-01-2022 UFC 3-120-01 Design: Sign Standards, 02-01-2023 UFC 3-120-10 Interior Design, 06-15-2021 UFC 3-190-06 Protective Coatings and Paints, 03-01-2021 UFC 4-720-01 Lodging Facilities, 02-13-2012

Structural Interior Design Package interior design

Meeting Minutes interior design

1 | P a g e

1008 Granby Street | Norfolk, VA 23510 | 757.224.0489

MEETING MINUTES

Project: Repair BEQ FC555 Meeting: 50% Review Meeting Date: October 30th, 2025 Location: Microsoft Teams Meeting

PROJECT TEAM IN ATTENDANCE:

Architecture MBF Architects (252) 637-6373 Civil Engineer Avolis Engineering (252) 633-0068 Structural Engineer Kaydos-Daniels Engineers (919) 828-4966 Mechanical/Electrical/Plumbing Crenshaw Consulting (919) 871-1070 Fire Protection Jensen Hughes (757) 213-6856 Cost Estimating Aiken Cost Consultants (864) 232-9342 Geotechnical ECS Southeast (919) 861-9910 Interior Design Within Interior Design (757) 224-0489

Below are the items that were addressed at the 50% Review Meeting.

50% REVIEW COMMENTS

REVIEWER: KELLY ROOT

Item #3 I-111 – I-113: Bachelor housing is requesting we keep existing room numbers. They've had trouble with signage.

Response: Concur. Coordinate with MBF.

Item #37 I-101: I’m thinking we make the offices Resinous Flooring. Throughs?

Response: Concur. Floor finish in offices will be updated to Resinous Flooring RES-1.

Item #38 I-102: Rm 239 is telecom. Rm 238 is linen.

Response: Concur. Room name will be corrected.

Item #39 I-103: Rm 339 is office. Rm 338 is linen.

Response: Concur. Room name will be corrected.

Item #40 I-101 – I-103: Coordinate washer/dryer counts with arch

Response: Concur. Linked model will be updated to match Arch drawings.

Item #41 I-101 – I-103: Can you add the exterior walkway finish called out on these plans?

Response: Concur. RES-2 will be added to the exterior walkways on the finish plans.

2 | P a g e

Item #42 A2,C2/I-201: Can we put all drawers on this cabinet where section marker is taken?

Response: Concur. Base cabinet will be changed to 4 drawer cabinet.

Item #43 A3,C3/I-201: Add (5) 8-12" shelves on plan north wall. Make closet rod and shelf full width

Response: Concur. Closet casework will be revised.

Item #44 C1/I-201: Add medicine cabinet(s).

Response: Concur. WID will coordinate with MBF to update mirrors to include recessed medicine cabinet.

Item #45 A1,C1/I-201: Add corner cabinet and extend upper cabinets to the same extent of lower cabinets. Max size for fridge/microwave unit is 72" so I don't think we can fit cabinets above that.

Response: Concur. Casework will be revised.

Item #46 D4/I-301: Add additional shelf.

Response: Concur. Shelf will be added.

Item #47 I-201 & I-301: Continue SS to bottom of cabinets, not just a backsplash as kitchenette.

Response: Concur. Casework will be revised to show full-height solid surface backsplash.

Item #48 I-301: Bathroom vanity should have integral SS bowl.

Response: Concur. Section drawing will be revised to show integral SS bowl.

REVIEWER: FRANKLIN ETIENNE

Item #5 I-402: Room 239 is COMM (not linen storage).

Response: Concur. Room name will be revised.

Item #6 I-601: Room 239 is COMM (Not Linen Storage).

Response: Concur. Room name will be revised.

Item #7 I-601: Flooring should be SC-1 (Not RES-1).

Response: Concur. Floor finish will be revised.

ACTION ITEMS

1. 95% Submittal due to government on 12/22/25.

Meeting: 95% Review Meeting Date: January 22nd, 2026 Location: 1005 Michael Rd, Camp Lejeune, NC

PROJECT TEAM IN ATTENDANCE:

Architecture MBF Architects (252) 637-6373 Civil Engineer Avolis Engineering (252) 633-0068 Structural Engineer Kaydos-Daniels Engineers (919) 828-4966 Mechanical/Electrical/Plumbing Crenshaw Consulting (919) 871-1070 Fire Protection Jensen Hughes (757) 213-6856 Cost Estimating Aiken Cost Consultants (864) 232-9342 Geotechnical ECS Southeast (919) 861-9910 Interior Design Within Interior Design (757) 224-0489

Below are the items that were addressed at the 95% Review Meeting.

95% REVIEW COMMENTS

REVIEWER: TREVOR STREETER

Item #12 I-501: Reflect the accessible sign design, layout, and fonts as additional typical signage details.

Response: Concur. Details regarding high contrast/non-glare finishes, sans serif fonts, signage clarity and domed braille have been added to the SIGNAGE NOTES.

Item #16 I-101: Concrete flooring in the vending/corridor area changes to Resilient flooring in the kitchen and is not "technically" combustible-proof.

Response: Concur. Kitchen flooring will be changed to quarry tile.

Item #17 Is there a reason why sleeping rooms 131 and 315 have signage pointing to S7? When all of the other sleeping rooms have S1? Ensure all rooms have the correct exterior signage and that the overall count of these signs is reflected on the signage schedule on I-111, I- 112, and I-113.

Response: Concur. These signs have been corrected.

Item #25 I-202: Label grout joint thickness (A1, A3).

Response: Concur. Grout thickness note will be added.

REVIEWER: CATHY MARTIN

Item #28 I-Sheets: The drawing package is missing the sleeping room furniture sheets, please add.

Response: FF&E & Furniture Plans are not included in the Interiors scope – MBF confirmed furniture layouts will be covered in Arch drawings.

Item #29 I-103: Replace room tag for room 339 to reflect OFFICE in lieu of COMM room.

Response: Concur. Room name will be corrected.

Item #35 I-301: Bathroom vanity should have integral ss bowl. (from 50% comments)

Response: Concur. Section drawing will be revised with added notation.

Item #36 I-601: Add mechanical buildings to room finish schedule

Response: Concur. Mechanical Building will be added.

ADDITIONAL NOTES

• Cathy Martin will provide a revised FF&E layout to MBF that will accommodate the PTAC and bump out at corner rooms.

ACTION ITEMS

1. Digital Final Submittal due to government on 2/12/26.

Meeting: Final Review Meeting Date: March 24th, 2026 Location: 1005 Michael Rd, Camp Lejeune, NC

PROJECT TEAM IN ATTENDANCE:

Architecture MBF Architects (252) 637-6373 Civil Engineer Avolis Engineering (252) 633-0068 Structural Engineer Kaydos-Daniels Engineers (919) 828-4966 Mechanical/Electrical/Plumbing Crenshaw Consulting (919) 871-1070 Fire Protection Jensen Hughes (757) 213-6856 Cost Estimating Aiken Cost Consultants (864) 232-9342 Geotechnical ECS Southeast (919) 861-9910 Interior Design Within Interior Design (757) 224-0489

Below are the items that were addressed at the 95% Review Meeting.

FINAL REVIEW COMMENTS

REVIEWER: CATHY MARTIN

Item #17 I-601: Add mechanical buildings to room finish schedule

Response: Concur. Mechanical Building will be added.

Item #18 I-Sheets: The drawing package is missing the sleeping room furniture sheets, please add.

Response: FF&E & Furniture Plans are not included in the Interiors scope – MBF confirmed furniture layouts will be covered in Arch drawings.

Item #19 I-103: Replace room tag for room 339 to reflect OFFICE in lieu of COMM room.

Response: Concur. Room name will be corrected.

REVIEWER: TREVOR STREETER

Item #20 I-112/113: Should sleeping rooms 213, 215, 313, and 315 have signage reflect the other sleeping rooms (S1) instead of (S7)?

Response: Concur. These signs have been corrected

Item #21 I-202: Label grout joint thickness (A1, A3).

Response: Concur. Grout thickness to be added

Item #22 I-501: Reflect the accessible sign design, layout, and fonts as additional typical signage details.

Response: Avolis - Will provide Hc parking signage,route.

Concur. Details regarding high contrast/non-glare finishes, sans serif fonts, signage clarity and domed braille have been added to the SIGNAGE NOTES.

Item #23 I-101/102/103: If fixtures are shown in one room, it should be reflected throughout. Ensure towel bars, toilet paper dispensers, etc... are either all shown in the respective drawing sets, or are hidden until notated later. I'd hate for the wrong amount of something to be ordered or not factored into installation because it wasn't visually portrayed when it should have been, or hidden and given its own detail/enlarged sheet later-on. (A small note to tack on, women's toilet 140 and 147 is like this, where the hand dryer/paper towel dispenser is in one, but not another.)

Response: Updated. (MBFA)

Item #24 I-111: Can we have Janitor Room 141 swing into the laundry room 133? Might make access easier for the maintenance staff, rather than trapsing through an admin office during the middle of the day.

Response: MBF will make adjustments.

REVIEWER: DOUG STULTZ

Item #90 Spec Section 10 14 00.20: Related to Previous Comment GI10x floor Plans: (General Note 5: Please spell out the fire rating barrier marking per IBC section 703.5.) Prime Contractor and their sub-tier painting contractor need these requirements within a spec section. Insert the fire/smoke barrier signage requirements of IBC §703.5 into Spec Section 10 14 00.20 Interior Signage of if more appropriate Spec Section 09 90 00 Paints and Coatings

Response: Within will make adjustment. Verbiage provided by Doug will be added to the interior signage spec.

Structural Interior Design Package interior design

Finish Plans & Schedules

FLOOR FINISH KEY

LVT-1

T-1

RES-1

SC-1

RES-2

T-4

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

CLERK'S

OFFICE

ADMINISTRATIVE

OFFICE

NO. 1

ADMINISTRATIVE

OFFICE

NO. 2

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

X.O.

OFFICE

C.O.

OFFICE

STORAGE

1ST SGT'S

OFFICE

143 MEN'S

TOILET

MECH.

WOMEN'S

TOILET

MECH

JAN

LAUNDRY

LAUNDRY

CORR.

JAN

OFFICE

ADMINISTRATIVE

OFFICE NO.

JAN

WOMEN'S

TOILET

KITCHEN

X.O.

OFFICE

1ST SGT'S

OFFICE

ADMINISTRATIVE

OFFICE NO.

CLERK'S

OFFICE

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

ELECTRICAL

VENDING

MECH.MECH. MECH.

I-401 B1

I-401 B5

SLEEPING

ROOM

***HATCH PATTERN DOES NOT INDICATE DIRECTION OR METHOD OF FLOORING INSTALLATION.

Fi le

P at h:

Pr in t D at e:

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

1008 GRANBY

STREET

NORFOLK, VA 23510

757.224.0489

05-25-0009

CHRIS MAAS

W :\2

FC

BE

Q R en ov at io n C

L\ R ev it\

B

FC

W

ID

R

.rv t

5/

/2

4:

:4

PM

I-101

APG

JDK

JDK REPAIR BEQ FC555

FIRST FLOOR FINISH PLAN

60042659 : N40085-25-B-0009

SCALE: 1/8" = 1'-0"A1 1ST FLOOR FINISH PLAN

4' 8' 16'0' 1/8" =1'-0"

GRAPHIC SCALE:

FINISH NOTES

A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO

CONVEY COLOR, PATTERN, TEXTURE AND SALIENT

CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER

INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF

PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED

AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF

RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND

APPROVED BY THE CONTRACTING OFFICER.

B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING

LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO

ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.

C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL

DRAWINGS AND CONSTRUCTION MANAGER. INSTALL

THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT

SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF

A WALL.

FINISH NOTES

J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE

INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO

BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE

PAINTED (PNT-6).

K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).

L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID

SURFACE (SS-3).

M. ALL INTERIOR WOOD DOORS TO BE (WD-1).

N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING

SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH

(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).

SEE DETAIL A3/1-202.

O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO

MATCH EXISTING CONDITIONS.

P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH

SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE

TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.

Q. SEE I-601 FOR FINISH LEGEND.

FINISH NOTES

D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,

AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.

E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS

F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.

PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE

G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.

FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE

CENTERED UNDER DOOR.

H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE

METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS

WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE

WHERE APPLICABLE FOR A COMPLETE INSTALLATION.

I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE

EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY

RESINOUS FLOORING.

I G

IV R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR

DE

SI

GN

ENo.

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECH.

LAUNDRY

LOUNGE

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

JAN

ELECTRICAL

LINEN

STORAGE

COMM

CORR.

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECH. MECH.

WG-1

WG-1

***HATCH PATTERN DOES NOT INDICATE DIRECTION OR METHOD OF FLOORING INSTALLATION.

FLOOR FINISH KEY

LVT-1

T-1

RES-1

SC-1

RES-2

T-4

A B

C D

Fi le

P at h:

P rin t D at e:

E

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

2 3 4 5 6

A B

C D

E

1 2 3 4 5 6

1008 GRANBY STREET

NORFOLK, VA 23510

757.224.0489

05-25-0009

CHRIS MAAS

W :\2

FC

BE

Q R en ov at io n C

L\ R ev it\

B

FC

W

ID

R

.rv t

5/ 8/

:4

2:

P M

I-102

APG

JDK

JDK REPAIR BEQ FC555

SECOND FLOOR FINISH PLAN

60042660 : N40085-25-B-0009

4' 8' 16'0' 1/8" =1'-0"

GRAPHIC SCALE:

SCALE: 1/8" = 1'-0"A1 2ND FLOOR FINISH PLAN

FINISH NOTES

A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO

CONVEY COLOR, PATTERN, TEXTURE AND SALIENT

CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER

INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF

PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED

AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF

RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND

APPROVED BY THE CONTRACTING OFFICER.

B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING

LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO

ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.

C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL

DRAWINGS AND CONSTRUCTION MANAGER. INSTALL

THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT

SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF

A WALL.

FINISH NOTES

J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE

INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO

BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE

PAINTED (PNT-6).

K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).

L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID

SURFACE (SS-3).

M. ALL INTERIOR WOOD DOORS TO BE (WD-1).

N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING

SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH

(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).

SEE DETAIL A3/1-202.

O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO

MATCH EXISTING CONDITIONS.

P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH

SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE

TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.

Q. SEE I-601 FOR FINISH LEGEND.

FINISH NOTES

D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,

AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.

E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS

F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.

PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE

G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.

FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE

CENTERED UNDER DOOR.

H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE

METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS

WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE

WHERE APPLICABLE FOR A COMPLETE INSTALLATION.

I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE

EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY

RESINOUS FLOORING.

I G

IV R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR

DE

SI

E No.

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECH.

LOUNGE

LAUNDRY

JAN

ELECTRICAL

LINEN

STORAGE

CORR.

OFFICE

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECH. MECH.

WG-1

WG-1

***HATCH PATTERN DOES NOT INDICATE DIRECTION OR METHOD OF FLOORING INSTALLATION.

FLOOR FINISH KEY

LVT-1

T-1

RES-1

SC-1

RES-2

T-4

A B

C D

Fi le

P at h:

P rin t D at e:

E

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

2 3 4 5 6

A B

C D

E

1 2 3 4 5 6

1008 GRANBY STREET

NORFOLK, VA 23510

757.224.0489

05-25-0009

CHRIS MAAS

W :\2

FC

BE

Q R en ov at io n C

L\ R ev it\

B

FC

W

ID

R

.rv t

5/ 8/

:4

2:

P M

I-103

APG

JDK

JDK REPAIR BEQ FC555

THIRD FLOOR FINISH PLAN

60042661 : N40085-25-B-0009

4' 8' 16'0' 1/8" =1'-0"

GRAPHIC SCALE:

SCALE: 1/8" = 1'-0"A1 3RD FLOOR FINISH PLAN

FINISH NOTES

A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO

CONVEY COLOR, PATTERN, TEXTURE AND SALIENT

CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER

INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF

PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED

AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF

RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND

APPROVED BY THE CONTRACTING OFFICER.

B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING

LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO

ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.

C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL

DRAWINGS AND CONSTRUCTION MANAGER. INSTALL

THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT

SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF

A WALL.

FINISH NOTES

J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE

INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO

BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE

PAINTED (PNT-6).

K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).

L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID

SURFACE (SS-3).

M. ALL INTERIOR WOOD DOORS TO BE (WD-1).

N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING

SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH

(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).

SEE DETAIL A3/1-202.

O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO

MATCH EXISTING CONDITIONS.

P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH

SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE

TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.

Q. SEE I-601 FOR FINISH LEGEND.

FINISH NOTES

D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,

AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.

E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS

F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.

PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE

G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.

FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE

CENTERED UNDER DOOR.

H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE

METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS

WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE

WHERE APPLICABLE FOR A COMPLETE INSTALLATION.

I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE

EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY

RESINOUS FLOORING.

I G

IV R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR

DE

SI

MECH.MECH. MECH. MECH.

S1 S1 S1 S1 S1 S7 S1 S1 S1 S1 S1

S1S1S1S1S1S1S1S1S1S1 S2 S2

S6S6

S4S4

S8 S8

S7

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

CLERK'S

OFFICE

ADMINISTRATIVE

OFFICE

NO. 1

ADMINISTRATIVE

OFFICE

NO. 2

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

X.O.

OFFICE

C.O.

OFFICE

STORAGE

MEN'S

TOILET

WOMEN'S

TOILET

MECH

JAN

LAUNDRY

LAUNDRY

CORR.

JAN

OFFICE

ADMINISTRATIVE

OFFICE NO.

JAN

WOMEN'S

TOILET

KITCHEN

X.O.

OFFICE

1ST SGT'S

OFFICE

CLERK'S

OFFICE

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

ELECTRICAL

VENDING

SLEEPING

ROOM

ADMINISTRATIVE

OFFICE NO.

1ST SGT'S

OFFICE

I-402 B1

A B

C D

Fi le

P at h:

P rin t D at e:

E

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

2 3 4 5 6

A B

C D

E

1 2 3 4 5 6

1008 GRANBY STREET

NORFOLK, VA 23510

757.224.0489

05-25-0009

CHRIS MAAS

W :\2

FC

BE

Q R en ov at io n C

L\ R ev it\

B

FC

W

ID

R

.rv t

5/ 8/

:4

2:

P M

I-111

APG

JDK

JDK REPAIR BEQ FC555

FIRST FLOOR SIGNAGE PLAN

60042662 : N40085-25-B-0009

SIGNAGE SCHEDULE

TYPE DESCRIPTION QTY

S1 SLEEPING QUARTERS IDENTIFICATION SIGN 80

S2 PERMANENT ROOM IDENTIFICATION SIGN 37

S3 NON-PERMANENT ROOM IDENTIFICATION SIGN 3

S4 STAIRWELL LEVEL INDICATOR 9

S5M MENS RESTROOM IDENTIFICATION SIGN 1

S5W WOMENS RESTROOM IDENTIFICATION SIGN 2

S6 SMALL DIRECTIONAL SIGN 11

S7 EXTERIOR ROOM SIGN 13

S8 STAIRWELL IDENTIFICATION SIGN 10

SIGNAGE NOTES

A. ALL SIGNAGE TO COMPLY WITH UFC 3 120 01.

B. ALL SIGN TYPES, TEXT WORDING, AND ROOM NUMBERS TO BE VERIFIED

WITH END USER AND REVIEWED BY NAVFAC INTERIOR DESIGNER PRIOR TO

FABRICATION.

C. ALL GRADE 2 BRAILLE TO BE TACTILE RAISED 0.8 MM FROM THE SURFACE

WITH ROUNDED DOTS.

D. SIGNS MUST USE HIGH CONTRAST, NON-GLARE FINISHES. CHARACTERS

MUST BE UPPER CASE AND USE SANS SERIF FONTS.

E. SIGNS MUST INCLUDE CLEAR VISUAL ELEMENTS FOR INDIVIDUALS WITH

LOW VISION, BLINDNESS AND COGNITIVE DISABILITIES.

F. SIGNS THAT MOUNT TO GLASS MUST INCLUDE AN EQUALLY SIZED BLANK

SIGN PANEL ALIGNED TO OPPOSITE SIDE OF THE GLASS.

G. REFER TO SHEET I-501 FOR SIGNAGE DETAILS.

H. REFER TO SHEET I-601 FINISH LEGEND FOR SIGNAGE FINISHES.

I. MOUNTING OF SIGNAGE SYSTEM MUST INCLUDE SURFACE MOUNTING

WITH SCREW-ON APPLICATION FOR INTERIOR WALLS.

J. SEE ELEVATION I-501 FOR MOUNTING HEIGHT OF ACRYLIC SIGNAGE.

4' 8' 16'0' 1/8" =1'-0"

GRAPHIC SCALE:

SCALE: 1/8" = 1'-0"A1 1ST FLOOR SIGNAGE PLAN

I G

IV R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR

DE

SI

MECH. MECH.

S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1

S1S1S1S1S1S1S1S1S1S1

S6S6

S4S4

S1 S1

S8 S8

S2 S2S1S1S1 S1

S1S1S1

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECH.

LAUNDRY

LOUNGE

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

JAN

ELECTRICAL

LINEN

STORAGE

COMM

CORR.

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

I-402 B5

A B

C D

Fi le

P at h:

P rin t D at e:

E

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

2 3 4 5 6

A B

C D

E

1 2 3 4 5 6

1008 GRANBY STREET

NORFOLK, VA 23510

757.224.0489

05-25-0009

CHRIS MAAS

W :\2

FC

BE

Q R en ov at io n C

L\ R ev it\

B

FC

W

ID

R

.rv t

5/ 8/

:4

2:

P M

I-112

APG

JDK

JDK REPAIR BEQ FC555

SECOND FLOOR SIGNAGE PLAN

60042663 : N40085-25-B-0009

4' 8' 16'0' 1/8" =1'-0"

GRAPHIC SCALE:

SCALE: 1/8" = 1'-0"A1 2ND FLOOR SIGNAGE PLAN

SIGNAGE SCHEDULE

TYPE DESCRIPTION QTY

S1 SLEEPING QUARTERS IDENTIFICATION SIGN 80

S2 PERMANENT ROOM IDENTIFICATION SIGN 37

S3 NON-PERMANENT ROOM IDENTIFICATION SIGN 3

S4 STAIRWELL LEVEL INDICATOR 9

S5M MENS RESTROOM IDENTIFICATION SIGN 1

S5W WOMENS RESTROOM IDENTIFICATION SIGN 2

S6 SMALL DIRECTIONAL SIGN 11

S7 EXTERIOR ROOM SIGN 13

S8 STAIRWELL IDENTIFICATION SIGN 10

SIGNAGE NOTES

A. ALL SIGNAGE TO COMPLY WITH UFC 3 120 01.

B. ALL SIGN TYPES, TEXT WORDING, AND ROOM NUMBERS TO BE VERIFIED

WITH END USER AND REVIEWED BY NAVFAC INTERIOR DESIGNER PRIOR TO

FABRICATION.

C. ALL GRADE 2 BRAILLE TO BE TACTILE RAISED 0.8 MM FROM THE SURFACE

WITH ROUNDED DOTS.

D. SIGNS MUST USE HIGH CONTRAST, NON-GLARE FINISHES. CHARACTERS

MUST BE UPPER CASE AND USE SANS SERIF FONTS.

E. SIGNS MUST INCLUDE CLEAR VISUAL ELEMENTS FOR INDIVIDUALS WITH

LOW VISION, BLINDNESS AND COGNITIVE DISABILITIES.

F. SIGNS THAT MOUNT TO GLASS MUST INCLUDE AN EQUALLY SIZED BLANK

SIGN PANEL ALIGNED TO OPPOSITE SIDE OF THE GLASS.

G. REFER TO SHEET I-501 FOR SIGNAGE DETAILS.

H. REFER TO SHEET I-601 FINISH LEGEND FOR SIGNAGE FINISHES.

I. MOUNTING OF SIGNAGE SYSTEM MUST INCLUDE SURFACE MOUNTING

WITH SCREW-ON APPLICATION FOR INTERIOR WALLS.

J. SEE ELEVATION I-501 FOR MOUNTING HEIGHT OF ACRYLIC SIGNAGE.

I G

IV R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR

DE

SI

MECH. MECH.

S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1

S1S1S1S1S1S1S1S1S1S1

S6S6

S4S4

S1 S1

S8 S8

S2 S2S1S1S1 S1

S1S1S1

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECH.

LAUNDRY

LOUNGE

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

JAN

ELECTRICAL

LINEN

STORAGE

OFFICE

CORR.

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

MECHANICAL

SLEEPING

ROOM

SLEEPING

ROOM

SLEEPING

ROOM

I-402 B5

A B

C D

Fi le

P at h:

P rin t D at e:

E

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

2 3 4 5 6

A B

C D

E

1 2 3 4 5 6

1008 GRANBY STREET

NORFOLK, VA 23510

757.224.0489

05-25-0009

CHRIS MAAS

W :\2

FC

BE

Q R en ov at io n C

L\ R ev it\

B

FC

W

ID

R

.rv t

5/ 8/

:4

2:

P M

I-113

APG

JDK

JDK REPAIR BEQ FC555

THIRD FLOOR SIGNAGE PLAN

60042664 : N40085-25-B-0009

4' 8' 16'0' 1/8" =1'-0"

GRAPHIC SCALE:

SCALE: 1/8" = 1'-0"A1 3RD FLOOR SIGNAGE PLAN

SIGNAGE SCHEDULE

TYPE DESCRIPTION QTY

S1 SLEEPING QUARTERS IDENTIFICATION SIGN 80

S2 PERMANENT ROOM IDENTIFICATION SIGN 37

S3 NON-PERMANENT ROOM IDENTIFICATION SIGN 3

S4 STAIRWELL LEVEL INDICATOR 9

S5M MENS RESTROOM IDENTIFICATION SIGN 1

S5W WOMENS RESTROOM IDENTIFICATION SIGN 2

S6 SMALL DIRECTIONAL SIGN 11

S7 EXTERIOR ROOM SIGN 13

S8 STAIRWELL IDENTIFICATION SIGN 10

SIGNAGE NOTES

A. ALL SIGNAGE TO COMPLY WITH UFC 3 120 01.

B. ALL SIGN TYPES, TEXT WORDING, AND ROOM NUMBERS TO BE VERIFIED

WITH END USER AND REVIEWED BY NAVFAC INTERIOR DESIGNER PRIOR TO

FABRICATION.

C. ALL GRADE 2 BRAILLE TO BE TACTILE RAISED 0.8 MM FROM THE SURFACE

WITH ROUNDED DOTS.

D. SIGNS MUST USE HIGH CONTRAST, NON-GLARE FINISHES. CHARACTERS

MUST BE UPPER CASE AND USE SANS SERIF FONTS.

E. SIGNS MUST INCLUDE CLEAR VISUAL ELEMENTS FOR INDIVIDUALS WITH

LOW VISION, BLINDNESS AND COGNITIVE DISABILITIES.

F. SIGNS THAT MOUNT TO GLASS MUST INCLUDE AN EQUALLY SIZED BLANK

SIGN PANEL ALIGNED TO OPPOSITE SIDE OF THE GLASS.

G. REFER TO SHEET I-501 FOR SIGNAGE DETAILS.

H. REFER TO SHEET I-601 FINISH LEGEND FOR SIGNAGE FINISHES.

I. MOUNTING OF SIGNAGE SYSTEM MUST INCLUDE SURFACE MOUNTING

WITH SCREW-ON APPLICATION FOR INTERIOR WALLS.

J. SEE ELEVATION I-501 FOR MOUNTING HEIGHT OF ACRYLIC SIGNAGE.

I G

IV R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR

DE

SI

D1 I-301

_______ A1 I-301

D3 I-301

SS-1

PLAM-1

FILLER STRIPS

PLAM-1

CABINETS

RB-1

TOE KICK

PLAM-1

CABINETS

SINKS CENTERED

ON CASEWORK

PLAM-1

FILLER STRIP

PNT-1

1" 28" 2"

24"1"30"1"

1" 26"

ANGLED

12" 15"

A2 I-301

D4 I-301

SS-1

PLAM-1

CABINETS

RB-1

TOE KICK

GFGI MICRO-

FRIDGE UNIT

PNT-1

PLAM-1

CABINETS

SCRIBE TO

CEILING

24" 2" 14"

FIELD VERIFY

25"

15"

ANGLED

12" 12"

A4 I-301

36" 12"

48"

3/4" PLYWOOD SHELF WITH

3/4"X1-1/2" HARDWOOD

NOSING. STAIN

1"X6" HARDWOOD CLEAT,

CONTINUOUS 3 SIDES

CLOSET ROD AS SPECIFIED

SECURE CASEWORK TO

WALL WITH MASONARY

ANCHOR , 10" O.C.

3/4" PLYWOOD SHEVES WITH

3/4"X1-1/2" HARDWOOD

NOSING. STAIN

RB-1

WALL BASE

A3 I-301

12" 36"

48"

3/4" PLYWOOD SHELF WITH

3/4"X1-1/2" HARDWOOD

NOSING. STAIN

1"X6" HARDWOOD CLEAT,

CONTINUOUS 3 SIDES

CLOSET ROD AS SPECIFIED

SECURE CASEWORK TO

WALL WITH MASONARY

ANCHOR , 10" O.C.

3/4" PLYWOOD SHELVES WITH

3/4"X1-1/2" HARDWOOD

NOSING. STAIN

RB-1

WALL BASE

A2 I-301

D4 I-301

SS-1

PLAM-1

CABINETS

RB-1

TOE KICK

GFGI MICRO-

FRIDGE UNIT

PNT-1

PLAM-1

CABINETS

FIELD VERIFY

25" 14" 2" 24"

12"

ANGLED

12" 15"

1"30"1"

SS-1

PLAM-1

FILLER STRIPS

PLAM-1

CABINETS

RB-1

TOE KICK

PLAM-1

CABINETS

SINKS CENTERED

ON CASEWORK

PLAM-1

FILLER STRIP

MIRRORED

CABINET

SS-1

PNT-1

CP-1

CABINET PULLS

24" 2" 28" 1"

26"

ANGLED

12"15"

D3 I-301

A1 I-301

_______ D1 I-301

30"18"

3/4" PLYWOOD SHELF WITH

3/4"X1-1/2" HARDWOOD

NOSING. STAIN

1"X6" HARDWOOD CLEAT,

CONTINUOUS 3 SIDES

CLOSET ROD AS SPECIFIED

SECURE CASEWORK TO

WALL WITH MASONARY

ANCHOR , 10" O.C.

3/4" PLYWOOD SHELVES WITH

3/4"X1-1/2" HARDWOOD

NOSING. STAIN

RB-1

WALL BASE

A3 I-301

48"

30" 18"

3/4" PLYWOOD SHELF WITH

3/4"X1-1/2" HARDWOOD

NOSING. STAIN

1"X6" HARDWOOD CLEAT,

CONTINUOUS 3 SIDES

CLOSET ROD AS SPECIFIED

SECURE CASEWORK TO

WALL WITH MASONARY

ANCHOR , 10" O.C.

3/4" PLYWOOD SHELVES WITH

3/4"X1-1/2" HARDWOOD

NOSING. STAIN

RB-1

WALL BASE

A3 I-301

48"

A B

C D

Fi le

P at h:

P rin t D at e:

E

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

2 3 4 5 6

A B

C D

E

1 2 3 4 5 6

1008 GRANBY STREET

NORFOLK, VA 23510

757.224.0489

05-25-0009

CHRIS MAAS

W :\2

FC

BE

Q R en ov at io n C

L\ R ev it\

B

FC

W

ID

R

.rv t

5/ 8/

:4

2:

P M

I-201

APG

JDK

JDK REPAIR BEQ FC555

INTERIOR ELEVATIONS

60042665 : N40085-25-B-0009

FINISH NOTES

A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO

CONVEY COLOR, PATTERN, TEXTURE AND SALIENT

CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER

INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF

PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED

AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF

RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND

APPROVED BY THE CONTRACTING OFFICER.

B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING

LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO

ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.

C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL

DRAWINGS AND CONSTRUCTION MANAGER. INSTALL

THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT

SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF

A WALL.

FINISH NOTES

J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE

INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO

BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE

PAINTED (PNT-6).

K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).

L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID

SURFACE (SS-3).

M. ALL INTERIOR WOOD DOORS TO BE (WD-1).

N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING

SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH

(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).

SEE DETAIL A3/1-202.

O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO

MATCH EXISTING CONDITIONS.

P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH

SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE

TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.

Q. SEE I-601 FOR FINISH LEGEND.

CASEWORK NOTES

1. CASEWORK CONSTRUCTION AS INDICATED IN THE

DOCUMENTS MUST BE IN ACCORDANCE WITH A.W.I. QUALITY

STANDARDS FOR FLUSH OVERLAY CONSTRUCTION.

SEMI-EXPOSED SURFACES TO BE CONSTRUCTED USING

CUSTOM GRADE STANDARDS

2. ALL CASEWORK MUST BE IN COMPLIANCE WITH UFGS

SECTION 06 41 16.0 AND SECTION 06 61 1.

3. ALL COUNTERTOP AND BACK/SIDE SPLASHES TO BE SOLID

SURFACE (SS-1). BACK/SIDE SPLASHES ARE ONLY TO BE

APPLIED AT WALLS WITHOUT FULL HEIGHT SPLASH OR TILE.

4. ALL BASE CABINETS, WALL CABINETS, APRONS AND

SHROUDS WILL BE PLASTIC LAMINATE (PLAM-1).

5. ALL BASE CABINET TOE KICKS WILL BE RUBBER BASE (RB-1).

6. SEE SHEET I-601 FOR FINISH LEGEND.

SCALE: 3/4" = 1'-0"C1 TYP. BATHROOM VANITY & KITCHENETTE

0' 1' 2' 3' 3/4" =1'-0"

GRAPHIC SCALE:

SCALE: 3/4" = 1'-0"C2 TYP. KITCHENETTE

SCALE: 3/4" = 1'-0"C3 TYP. CLOSET ROD

FINISH NOTES

D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,

AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.

E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS

F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.

PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE

G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.

FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE

CENTERED UNDER DOOR.

H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE

METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS

WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE

WHERE APPLICABLE FOR A COMPLETE INSTALLATION.

I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE

EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY

RESINOUS FLOORING.

SCALE: 3/4" = 1'-0"A3 TYP. CLOSET ROD

SCALE: 3/4" = 1'-0"A2 TYP. KITCHENETTE

SCALE: 3/4" = 1'-0"A1 TYP. BATHROOM VANITY & KITCHENETTE

SCALE: 3/4" = 1'-0"C4 TYP. CLOSET CASEWORK

SCALE: 3/4" = 1'-0"A4 TYP. CLOSET CASEWORK

I G

IV R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR

DE

SI

36" 36" 36" 4" 24"

SS-1

PLAM-1

FILLER STRIP

PLAM-1

CABINETS

RB-1

TOE KICK

PLAM-1

CABINETS

SINK CENTERED

ON CASEWORK

CP-1

CABINET PULLS

36" 36" 36"

ANGLED

12" 15"

D3 I-301

_______ D4 I-301

D2 I-301

_______ A1 I-301

GFGI ICE

MACHINE

SS-1

PLAM-1

CABINETS

RB-1

TOE KICK

PLAM-1

CABINETS

PNT-1

CP-1

CABINET PULLS

GFGI

APPLIANCES

24" 4" 18" 18"

VERIFY W/ EQUIP.

30" 18" 18"

15"

ANGLED

12" 36" 30" 36"

CFCI

APPLIANCE

D4 I-301

_______ D3 I-301

A2 I-301

_______ D2 I-301

GFGI

APPLIANCE

C

O U

R

SE

S

C O

U R

SE

S

TO

C

EI

LI

N G

T-3

T-2

TS-5

T-2

B1 I-502

1/8" GROUT

THICKNESS

FRP-1

RB-2

PNT-1

C4 I-502

B3 I-502

TS-7

PNT-7

PNT-5

±7

STRINGER ACCENT PAINT (PNT-7) TO

REPLACE EXISTING PAINTED FINISH.

U P

TO

C

EI

LI

N G

FRP-1

RB-2C4

I-502

Fi le

P at h:

Pr in t D at e:

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

1008 GRANBY

STREET

NORFOLK, VA 23510

757.224.0489

05-25-0009

CHRIS MAAS

W :\2

FC

BE

Q R en ov at io n C

L\ R ev it\

B

FC

W

ID

R

.rv t

5/

/2

2:

:1

PM

I-202

APG

JDK

JDK REPAIR BEQ FC555

INTERIOR ELEVATIONS

60042666 : N40085-25-B-0009

FINISH NOTES

A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO

CONVEY COLOR, PATTERN, TEXTURE AND SALIENT

CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER

INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF

PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED

AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF

RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND

APPROVED BY THE CONTRACTING OFFICER.

B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING

LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO

ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.

C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL

DRAWINGS AND CONSTRUCTION MANAGER. INSTALL

THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT

SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF

A WALL.

FINISH NOTES

J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE

INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO

BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE

PAINTED (PNT-6).

K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).

L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID

SURFACE (SS-3).

M. ALL INTERIOR WOOD DOORS TO BE (WD-1).

N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING

SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH

(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).

SEE DETAIL A3/1-202.

O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO

MATCH EXISTING CONDITIONS.

P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH

SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE

TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.

Q. SEE I-601 FOR FINISH LEGEND.

CASEWORK NOTES

1. CASEWORK CONSTRUCTION AS INDICATED IN THE

DOCUMENTS MUST BE IN ACCORDANCE WITH A.W.I. QUALITY

STANDARDS FOR FLUSH OVERLAY CONSTRUCTION.

SEMI-EXPOSED SURFACES TO BE CONSTRUCTED USING

CUSTOM GRADE STANDARDS

2. ALL CASEWORK MUST BE IN COMPLIANCE WITH UFGS

SECTION 06 41 16.0 AND SECTION 06 61 1.

3. ALL COUNTERTOP AND BACK/SIDE SPLASHES TO BE SOLID

SURFACE (SS-1). BACK/SIDE SPLASHES ARE ONLY TO BE

APPLIED AT WALLS WITHOUT FULL HEIGHT SPLASH OR TILE.

4. ALL BASE CABINETS, WALL CABINETS, APRONS AND

SHROUDS WILL BE PLASTIC LAMINATE (PLAM-1).

5. ALL BASE CABINET TOE KICKS WILL BE RUBBER BASE (RB-1).

6. SEE SHEET I-601 FOR FINISH LEGEND.

0' 1' 2' 3' 3/4" =1'-0"

GRAPHIC SCALE:

FINISH NOTES

D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,

AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.

E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS

F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.

PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE

G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.

FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE

CENTERED UNDER DOOR.

H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE

METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS

WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE

WHERE APPLICABLE FOR A COMPLETE INSTALLATION.

I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE

EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY

RESINOUS FLOORING.

SCALE: 3/4" = 1'-0"C1 COMMON KITCHEN 116 ELEVATION

SCALE: 3/4" = 1'-0"C3 COMMON KITCHEN 116 ELEVATION

SCALE: 3/4" = 1'-0"A1 TYP. RESTROOM TILE ELEVATION

SCALE: 3/4" = 1'-0"A2 TYP. JANITOR FRP ELEVATION

SCALE: 1 1/2" = 1'-0"A4 STAIR STRINGER PAINT DETAIL

4"0' 1 1/2" =1'-0"

8" 1'-4"

SCALE: 3/4" = 1'-0"A3 TYP.DRYER CHASE ELEVATION

I G

IV R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR

DE

SI

ENo.

SOLID SURFACE

COUNTERTOP WITH

EASED EDGE

HPL OVER 3/4"

PLYWOOD ON ALL

EXPOSED SURFACES

24"

HPL

INTERIOR

1/

2"

1/ 2"

4"

3" 21"

STAINLESS STEEL

BAR PULL

RUBBER BASE

AT TOE KICK

FULL HEIGHT SOLID

SURFACE BACKSPLASH

24"

3/ 4"

4" 3/

4"

UNDERMOUNT

STAINLESS STEEL SINK

I-502 B4

HPL ADJUSTABLE

SHELVES W/ 1-1/4"

LINE BORE

3/4" X 1-1/2"

HARDWOOD NOSING.

STAIN

SECURE

CASEOWORK W/

MASONRY ANCHOR,

10" O.C.

18"

1/

2"

1/ 2"

1/

2"

1/ 2"

1/

2"

1/ 2"

1X6 PLYWOOD CLEAT,

CONTINUOUS 3 SIDES

CLOSET ROD AS

SPECIFIED

HPL FIXED SHELF W/ 3/4"

PLYWOOD SUBSTRATE

3/4" X 1-1/2"

HARDWOOD NOSING.

STAIN TO MATCH HPL.

6"

18"

1/

2"

15"

FULL OVERLAY

FLUSH DOOR

FINISHED IN HPL

W/ MATCHING PVC

EDGEBAND

1/4" CABINET BACK

HPL INTERIOR

15"

FULL OVERLAY

FLUSH DOOR

FINISHED IN HPL

W/ MATCHING PVC

EDGEBAND

1/4" CABINET BACK

3/4" HPL ADJUSTABLE

SHELVES

HPL INTERIOR

RECESSED STANDARDS

SOLID SURFACE

COUNTERTOP

1/4" DRAWER

BOTTOM - DADO INTO

DRAWER BACK &

FRONT

INTERIOR

DRAWER BOXES

FINISHED IN HPL

1/4" CABINET BACK

DRAWER FRONTS

FINISHED IN HPL

W/ MATCHING PVC

EDGEBAND

RUBBER BASE

AT TOE KICK

FULL EXTENSION

DRAWER SLIDES

3" 21"

24"

1/

2"

3/ 8"

3/

4"

1/ 8"

1/

2"

1/ 8"

1/

2"

1/ 8"

9" 4"

FULL HEIGHT SOLID

SURFACE BACKSPLASH

24"

SOLID SURFACE

COUNTERTOP WITH

EASED EDGE

HPL OVER 3/4"

PLYWOOD ON ALL

EXPOSED INTERIOR &

EXTERIOR SURFACES

24"

1/

2"

1/ 2"

4"

3" 21"

RUBBER BASE

AT TOE KICK

24"

3/ 4"

4" 3/

4"

INTERIOR DRAWER

BOX FINISHED IN HPL

FULL EXTENSION

DRAWER SLIDES

FULL HEIGHT SOLID

SURFACE BACKSPLASH

3/4" HPL ADJUSTABLE

SHELF

RECESSED STANDARDS

SOLID SURFACE

COUNTERTOP WITH

EASED EDGE

HPL OVER 3/4"

PLYWOOD ON ALL

EXPOSED SURFACES

24"

HPL

INTERIOR

1/

2"

1/ 2"

4"

3" 21"

STAINLESS STEEL

BAR PULL

RUBBER BASE

AT TOE KICK

4" INTEGRAL

BACKSPLASH (FULL

HEIGHT SPLASH AT

KITCHENETTE)

24"

3/ 4"

4" 3/

4"

INTEGRAL SOLID

SURFACE BOWL

I-502 B4

A B

C D

Fi le

P at h:

P rin t D at e:

E

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

2 3 4 5 6

A B

C D

E

1 2 3 4 5 6

1008 GRANBY STREET

NORFOLK, VA 23510

757.224.0489

05-25-0009

CHRIS MAAS

W :\2

FC

BE

Q R en ov at io n C

L\ R ev it\

B

FC

W

ID

R

.rv t

5/ 8/

:4

2:

P M

I-301

APG

JDK

JDK REPAIR BEQ FC555

CASEWORK SECTIONS

60042667 : N40085-25-B-0009

CASEWORK NOTES

1. CASEWORK CONSTRUCTION AS INDICATED IN THE

DOCUMENTS MUST BE IN ACCORDANCE WITH A.W.I. QUALITY

STANDARDS FOR FLUSH OVERLAY CONSTRUCTION.

SEMI-EXPOSED SURFACES TO BE CONSTRUCTED USING

CUSTOM GRADE STANDARDS

2. ALL CASEWORK MUST BE IN COMPLIANCE WITH UFGS

SECTION 06 41 16.0 AND SECTION 06 61 1.

3. ALL COUNTERTOP AND BACK/SIDE SPLASHES TO BE SOLID

SURFACE (SS-1). BACK/SIDE SPLASHES ARE ONLY TO BE

APPLIED AT WALLS WITHOUT FULL HEIGHT SPLASH OR TILE.

4. ALL BASE CABINETS, WALL CABINETS, APRONS AND

SHROUDS WILL BE PLASTIC LAMINATE (PLAM-1).

5. ALL BASE CABINET TOE KICKS WILL BE RUBBER BASE (RB-1).

6. SEE SHEET I-601 FOR FINISH LEGEND.

4"0' 1 1/2" =1'-0"

GRAPHIC SCALE:

8" 1'-4"

SCALE: 1 1/2" = 1'-0"A1 SECTION - SINK CABINET

SCALE: 1 1/2" = 1'-0"A3 SECTION - CLOSET SHELVING

SCALE: 1 1/2" = 1'-0"A4 SECTION - CLOSET HANGING ROD

SCALE: 1 1/2" = 1'-0"D3 SECTION - UPPER CABINET 18"H

SCALE: 1 1/2" = 1'-0"D4 SECTION - UPPER CABINET 30"H

SCALE: 1 1/2" = 1'-0"A2 SECTION - 4 DRAWER BASE CAB.

SCALE: 1 1/2" = 1'-0"D2 SECTION - DOOR/DRAWER BASE CAB.

SCALE: 1 1/2" = 1'-0"D1 SECTION - RESTROOM SINK CABINET

I G

IV R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR

DE

SI

FLOOR FINISH KEY

LVT-1

T-1

RES-1

SC-1

RES-2

T-4

***HATCH PATTERN DOES NOT INDICATE DIRECTION OR METHOD OF FLOORING INSTALLATION.

LAUNDRY

MECH

LAUNDRY

JAN

CORR.

VENDING

ELECTRICAL

JAN

WOMEN'S

TOILET

MECH.

KITCHEN

ADMINISTRATIVE

OFFICE NO.

ADMINISTRATIVE

OFFICE NO.

1ST SGT'S

OFFICE

X.O.

OFFICE

OFFICE

PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

ADMINISTRATIVE

OFFICE

NO. 1

ADMINISTRATIVE

OFFICE

NO. 2

WOMEN'S

TOILET

JAN

MECH.

STORAGE

MEN'S

TOILET

C.O.

OFFICE

X.O.

OFFICE

PNT-2

1ST SGT'S

OFFICE

PNT-2

I-202

C1

C3

PN

T-

2CLERK'S

OFFICE

CLERK'S

OFFICE

PN

T-

I-202A3 A3

I-201

C1

SLEEPING

ROOM

PN

T-

PN

T-

2 SLEEPING

ROOM

C2

I-201 A3I-201C3I-201C3 I-201 A3

I-201

A1

A2

C4 A4C4 A4

MECHACNICAL

BLDG.

EXISTING

MECH.

BLDG.

A B

C D

Fi le

P at h:

P rin t D at e:

E

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

2 3 4 5 6

A B

C D

E

1 2 3 4 5 6

1008 GRANBY STREET

NORFOLK, VA 23510

757.224.0489

05-25-0009

CHRIS MAAS

W :\2

FC

BE

Q R en ov at io n C

L\ R ev it\

B

FC

W

ID

R

.rv t

5/ 8/

:4

2:

P M

I-401

APG

JDK

JDK REPAIR BEQ FC555

ENLARGED FINISH PLANS

60042668 : N40085-25-B-0009

2' 4' 8'0' 1/4" =1'-0"

GRAPHIC SCALE:

SCALE: 1/4" = 1'-0"B1 ENLARGED 1ST FLOOR COMMON AREA FINISH PLAN

SCALE: 1/4" = 1'-0"B5 ENLARGED SLEEPING ROOMS FINISH PLAN

FINISH NOTES

A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO

CONVEY COLOR, PATTERN, TEXTURE AND SALIENT

CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER

INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF

PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED

AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF

RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND

APPROVED BY THE CONTRACTING OFFICER.

B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO ORDERING

LEAD TIMES. IT IS THE CONTRACTOR’S RESPONSIBILITY TO

ORDER ALL MATERIALS IN TIME TO AVOID DELAYS.

C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL

DRAWINGS AND CONSTRUCTION MANAGER. INSTALL

THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT

SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER OF

A WALL.

FINISH NOTES

J. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE

INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES TO

BE PAINTED (PNT-5). ALL GWB & EXPOSED CEILINGS TO BE

PAINTED (PNT-6).

K. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).

L. ALL SHOWER FLOORS AND SHOWER WALLS TO BE SOLID

SURFACE (SS-3).

M. ALL INTERIOR WOOD DOORS TO BE (WD-1).

N. ALL STAIRS, STAIR LANDINGS, AND EXTERIOR FLOORING

SURFACES TO RECEIVE EPOXY RESINOUS FLOOR FINISH

(RES-2). STAIR STRINGERS TO RECEIVE PAINT FINISH (PNT-7).

SEE DETAIL A3/1-202.

O. EXTERIOR WALLS MUST BE CLEANED AND REPAINTED TO

MATCH EXISTING CONDITIONS.

P. LVT FLOORING COVERAGE INCLUDES THE ENTIRETY OF EACH

SLEEPING ROOM ALL THE WAY UP TO THE DOORWAY INTO THE

TOILET/SHOWER COMPARTMENT. SEE ENLARGED PLAN B5/I-401.

Q. SEE I-601 FOR FINISH LEGEND.

FINISH NOTES

D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT LOBBIES,

AND EXIT CORRIDORS MUST MEET MINIMUM CLASS A RATING.

E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS

F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.

PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE

G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.

FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST BE

CENTERED UNDER DOOR.

H. ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS MUST INCLUDE

METAL TRANSITIONS ON ALL OUTSIDE AND INSIDE CORNERS AS

WELL AS THE INTERSECTION BETWEEN FLOOR AND WALL TILE

WHERE APPLICABLE FOR A COMPLETE INSTALLATION.

I. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1) WITH THE

EXCEPTION OF AREAS RECEIVING FLOOR TILE OR EPOXY

RESINOUS FLOORING.

0' 2' 4' 6' 3/8" =1'-0"

SCALE: 1/4" = 1'-0"A1 ENLARGED MECHANICAL BLDG. 556A FINISH PLAN

SCALE: 1/4" = 1'-0"A2 ENLARGED MECHANICAL BLDG. 555A FINISH PLAN

I G

IV R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR

DE

SI

S6

S4

S6

S2

S2

S2

S2

S8

MECH

LAUNDRY

LAUNDRY

OFFICE

VENDING

ELECTRICAL

JAN

CORR.

S2

S2

S2

S7

S2

S2

ADMINISTRATIVE

OFFICE NO.

117 ADMINISTRATIVE

OFFICE NO.

WOMEN'S

TOILET

JAN

MECH.

KITCHEN

1ST SGT'S

OFFICE

X.O.

OFFICE

S3

X.O.

OFFICE

C.O.

OFFICE

STORAGE

MEN'S

TOILET

1ST SGT'S

OFFICE

ADMINISTRATIVE

OFFICE

NO. 1

ADMINISTRATIVE

OFFICE

NO. 2

JAN

WOMEN'S

TOILET

S3 S3

S2

S7 S7 S7 S7

S7

S2

S5W S5W

S5M

S2

MECH.

S8

S2

S6

S4

S8

S2

S2

S2

S2

S2

S2

S2

MECH.

LAUNDRY

JAN

ELECTRICAL

LINEN

STORAGE

COMM

CORR.

LOUNGE

S7

S2

S2

S6

S4

S8

S6

S2

S2

S2

S2

S2

S2

S7

S2

S2 S2

MECHACNICAL

BLDG.

S7

S7

A B

C D

Fi le

P at h:

P rin t D at e:

E

SYM. DESCRIPTION DATE APP.

REVISIONS

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

CERT. NO.

UTCETIHCRA

DERETSIG E R NOI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED:…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .