224004 Palmetto_100% ADD 02 PLUMBING_SS.pdf
PDF 1 MB Posted
- Attached to
- 224004 Palmetto Revamp
- Solicitation number
- ITB-15884
- Issued by
- St. Johns County, Florida
About this file
This is a plumbing specification document for the Palmetto Readiness Center renovation project (Project No. 224004) being executed by the State of Florida, Department of Military Affairs, with design services provided by BAL Engineering, Inc. and Renker Eich Park Architects. The scope of work encompasses replacement of fixture trim packages for existing lavatories, water closets, urinals, and sinks; refresh of existing showers with new valves, arms, and shower heads; replacement of existing shower trench drains; and replacement of existing electric tank-type water heaters with a hot water recirculation loop system. The work must comply with the 8th Edition (2023) Florida Building Code, applicable NFPA standards, ASHRAE guidelines, and SMACNA specifications. All plumbing materials, including PVC and cast iron drainage piping, copper and CPVC water piping, and isolation valves, must meet specified ASTM standards. The project includes detailed fixture schedules specifying acceptable manufacturers for components such as electric water coolers (Elkay VRCTL8WSK), tankless electric water heaters (EEMAX SPEX3208), commercial electric water heaters (A.O. Smith Gold XI DVE-120-27), and shower fixtures (Moen brand items). Hot water piping requires minimum one-inch fiberglass insulation with white ASJ or three-quarter-inch closed-cell foam split insulation. The project includes eight alternate bid items covering parking improvements, LED lighting upgrades, exterior facade refinishing, glazing replacement, fence installation, parking lot overlay, and dehumidifier installation in vault rooms.
The specifications establish comprehensive material and workmanship requirements, with all plumbing fixtures, pipes, and fittings warranted for one year after substantial completion. The contractor is responsible for coordinating all trade schedules, ensuring fixed work such as ductwork and plumbing is installed prior to easily relocable systems, and maintaining minimum clearances for service access, including 18 inches for wall cleanouts and 12-by-12-inch minimum locking access panels for valve access. Fire-rated penetrations must be sealed to maintain assembly ratings, and water hammer arrestors and air chambers must be provided at appropriate fixture connections. The specifications include detailed plumbing fixture schedules identifying connection sizes, trap configurations, and installation requirements for lavatories, water closets, urinals, service sinks, showers, and electric water coolers, with many existing fixtures to be removed and reinstalled or remain in place. The project document was prepared as 100% Construction Documents dated March 30, 2026, with Addendum 02 providing acceptable manufacturer specifications and additional technical requirements for specialty items.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FCO
VTR
WCO
GENERAL PLUMBING NOTES
P
220000
1. IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC AND SHOULD NOT BE SCALED.
2. INTENT OF THESE NOTES AND PLUMBING NOTES ON DRAWINGS IS TO CLARIFY THE SCOPE OF WORK.
3. THE CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL DAMAGE TO OWNER'S PROPERTY OR OTHER UNCOORDINATED TRADES
DURING THE COURSE OF CONSTRUCTION.
4. THE CONTRACTOR IS RESPONSIBLE FOR ALL TRADES INSTALLATION SCHEDULES. FIXED WORK SUCH AS DUCTWORK AND
PLUMBING SHALL BE INSTALLED PRIOR TO ANY TRADE WORK THAT CAN BE EASILY RELOCATED OR OFFSET SUCH AS ELECTRIC
CONDUITS, SMALL WATER LINES, ETC.
5. CONTRACTOR SHALL NOTIFY ARCHITECT/ENGINEER IN WRITING OF ANY CONFLICTS BETWEEN THE TRADES.
6. IN THE EVENT OF A CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND THE CODES, THE CODES SHALL TAKE PRECEDENCE.
7. CONTRACTOR SHALL PROVIDE ANY NECESSARY ITEMS NOT EXPRESSLY MENTIONED IN THE CONTRACT DOCUMENTS NEEDED TO
PROVIDE A COMPLETE PLUMBING SYSTEM.
8. UNLESS OTHERWISE NOTED, ALL PIPING SHALL BE LOCATED IN CONCEALED SPACES. PROVIDE MIN. 12"x12" LOCKING ACCESS
PANELS IN WALLS AND HARD CEILINGS FOR ACCESS TO VALVES.
9. PENETRATIONS FOR PIPES THROUGH ASSEMBLIES (FLOORS, ROOF, WALLS, PARTITIONS, ETC) WITH A REQUIRED FIRE RESISTANCE
RATING SHALL BE SEALED TO THE PENETRATING MEMBER IN AN APPROVED MANNER WHICH MAINTAINS THE REQUIRED FIRE
RESISTANCE RATING OF THE ASSEMBLY.
10. ALL PLUMBING FIXTURES, PIPES AND FITTINGS SHALL BE WARRANTED FOR 1 YEAR AFTER DATE OF SUBSTANTIAL COMPLETION.
11. PROVIDE WATER HAMMER ARRESTORS SIZE PDI "A" AT EACH PLUMBING FIXTURE CONNECTION INCORPORATING QUICK CLOSING
FAUCETS OR VALVES. PROVIDE AIR CHAMBERS AT ALL REMAINING FIXTURES WITHOUT SELF CLOSING VALVES.
12. WALL CLEANOUTS SHALL MAINTAIN A MINIMUM 18" CLEARANCE FOR SERVICE ACCESS.
13. ALL DRAINAGE AND VENT PIPING SHALL BE:
A. ALL MATERIALS SHALL BE NEW, FREE OF DAMAGE AND MEET THE FOLLOWING REQUIREMENTS:
a. PVC PIPE: SHALL BE MARKED AS MEETING ASTM D 2665 SPECIFICATION FOR PVC PLASTIC DRAIN, WASTE, AND
VENT PIPE AND FITTINGS AND/OR ASTM D 1785 SPECIFICATION FOR PVC PLASTIC PIPE, SCHEDULES 40, 80 AND 120.
b. CAST IRON: SHALL BE MARKED AS MEETING ASTM A888 OR CISPI 301 FOR CAST IRON PIPING
14. ALL DOMESTIC HOT AND COLD WATER PIPING SHALL BE:
A. ALL MATERIALS SHALL BE NEW, FREE OF DAMAGE AND MEETING THE FOLLOWING REQUIREMENTS:
a. COPPER PIPE: SHALL BE TYPE 'L' HARD TEMPER COPPER TUBING, ASTM B-88, WROUGHT COPPER FITTINGS, 95/5
TIN/ANTIMONY, NO-LEAD SOLDER.
b. CPVC PIPE: SHALL BE COPPER TUBE SIZE CPVC PIPE, ASTM 2846 WITH ASTM F 493 SOLVENT CEMENTS FOR
JOINING CPVC PIPE AND SOCKET FITTINGS.
15. ALL PLUMBING ISOLATION VALVES SHALL BE:
A. 1/2" - 3" SHALL BE QUARTER TURN , FULL PORT, ONE-PIECE BALL VALVES, BLOW OUT PROOF STEM, BRONZE BODY, STAINLESS STEEL BALL, TFE SEATS, EXTENDED NECK SUITABLE FOR INSULATION, SOLDERED, SCREWED OR
COMPRESSION FITTINGS. PUSH-ON FITTINGS WILL NOT BE ACCEPTED.
B. 4" - 12" SHALL BE RESILIENT WEDGE GATE VALVES, FLANGED CONNECTIONS, DUCTILE IRON AWWA/ANSI C515 BODY, DUCTILE IRON WEDGE WITH EPDM RUBBER SEALS, MUST BE NSF 61 AND NSF 372 LISTED.
16. INSULATION FOR HOT WATER PIPING:
A. MIN. 1" THICK FIBERGLASS INSULATION WITH WHITE ASJ. PREFORMED FITTINGS SHALL BE UTILIZED AT ALL STANDARD
ELBOWS AND FITTINGS.
B. MIN. 3/4" THICK CLOSED CELL FOAM SPLIT INSULATION.
CODE COMPLIANCE
P
220000
1. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE 8TH EDITION (2023) FLORIDA BUILDING CODE
A. BUILDING EDITION
B. EXISTING BUILDING EDITION
C. MECHANICAL EDITION
D. PLUMBING EDITION
E. FUEL GAS EDITION
F. ENERGY EFFICIENCY EDITION
G. 8TH EDITION (2023) FLORIDA FIRE PREVENTION CODE.
2. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
A. NFPA-1 NATIONAL FIRE CODE WITH FLORIDA MODIFICATIONS
B. NFPA-70 NATIONAL ELECTRIC CODE
C. NFPA-72 NATIONAL FIRE ALARM CODE
D. NFPA-101 NATIONAL LIFE SAFETY CODE
3. AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS, INC. (ASHRAE)
4. SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION (SMACNA)
SCOPE OF WORKP
220000
1. REPLACE EXISTING FIXTURE TRIM PACKAGES WITH NEW FOR EXISTING LAVATORIES, WATER
CLOSETS, URINALS AND SINKS.
2. REFRESH EXISTING SHOWERS WITH NEW VALVES, ARMS AND SHOWER HEADS.
3. REPLACE EXISTING SHOWER TRENCH DRAIN.
4. REPLACE EXISTING ELECTRIC TANK TYPE WATER HEATERS.
COTG
CO
HOT WATER RECIRC. LOOP
COLD WATER
DRAWING SYMBOL DESCRIPTION DRAWING SYMBOL
ABBREVIATION
HOT WATER (110°F)
UP TO LEVEL ABOVE
NOT IN CONTRACT
WATER CLOSET
URINAL
SERVICE SINK
FLOOR SINK
HOSE BIBB
ROOF HYDRANT
ELECTRIC WATER HEATER
GAS WATER HEATER
2-WAY CLEAN-OUT TO GRADE
STORM PIPING
SANITARY PIPING BELOW
SANITARY PIPING
KEYED NOTE
VENT PIPING
UNION
REVISION NOTE
PRESSURE GAUGE WITH
GAUGE COCK
HOSE BIBB OR WALL HYDRANT
THERMOMETER
FLOOR DRAIN
ROOF DRAIN
FLOOR SINK
WALL CLEAN OUT
VENT THRU ROOF
FLOOR CLEAN OUT
TWO-WAY CLEAN OUT
TO
GRADE
END OF PIPE CLEAN OUT
FLEXIBLE CONNECTION
GLOBE VALVE
PLUG VALVE
CHECK VALVE
Y-STRAINER WITH
DRAIN
VALVE
Y-STRAINER
BALL VALVE
ANGLE VALVE
GATE VALVE
PIPE DOWN
PIPE UP
HOT WATER RETURN LOOP
TEE FITTING PIPE UP
TEE FITTING PIPE DOWN
DOMESTIC HOT WATER
DOMESTIC COLD WATER
NEW EQUIPMENT
HB
VALVE
CONDENSATE DRAIN
SANITARY SEWER
ABBREVIATION
STORM WATER
DOWN TO LEVEL BELOW
UNLESS NOTED OTHERWISE
LAVATORY
SINK
FLOOR DRAIN
ROOF DRAIN
WALL HYDRANT
1/2" TRAP PRIMER
ELECTRIC WATER COOLER
DRINKING FOUNTAIN
HUB DRAIN
THE STANDARD SYMBOLS AND ABBREVIATION ABOVE MAY NOT BE USED. CONTRACTOR IS ONLY RESPONSIBLE FOR SYMBOLS CONTAINED WITHIN THE DOCUMENTS USED TO IDENTIFY REQUIRED SCOPE OF WORK.
DESCRIPTION
DESCRIPTIONDESCRIPTION
SUPPLY RETURN
COTG
GWH
HB
EWH
RH
FS
SS
NIC
UR
WC
UP
HWR
CW
HW
DN
CD
SS
ST
UNO
HD
DF
WH
EWC
TP
RD
FD
S
L
S R
LEGEND
P
220000
ABBREVIATIONS
EXISTING[E]
NEW[N]
REPLACE[R]
DEMOLISH[D]
DEMOLITION NOTE SYSTEM NOTE##
ALTERNATE BID ITEMS
A. ALTERNATE BID ITEM NO. 1: PARKING AREA - STORMWATER MITIGATION, ASPHALT MILLING, AND RESURFACE. CONNECT MAIN ARMORY ROOF DRAINS TO
UNDERGROUND STORM DRAIN SYSTEM.
B. ALTERNATE BID ITEM NO. 2: UPGRADE MAIN ARMORY BUILDING INTERIOR AND EXTERIOR LIGHTING TO LED TO INCLUDE UNIT SIGN AND FLAGPOLE.
C. ALTERNATE BID ITEM NO. 3: REFINISH AND REPAINT COMPLETE EXTERIOR STUCCO / BRICK FACADE WITH UP TO 4 COLOR SCHEME. INCLUDE THE PAINTING OF ALL
EXTERIOR HM DOORS AND FRAMES INCLUDING ALL INSIDE AND OUTSIDE FACES.
D. ALTERNATE BID ITEM NO. 4: COMPLETE GLAZING REPLACEMENT OF ALL EXISTING LAMINATED IMPACT GLAZING IN EXISTING ALUMINUM WINDOW FRAME SYSTEMS AT
THE EXTERIOR CLERESTORY LEVEL.
E. ALTERNATE BID ITEM NO. 5: COMPLETE GLAZING REPLACEMENT OF ALL EXISTING LAMINATED IMPACT GLAZING IN ALL EXISTING ALUMINUM WINDOW FRAME SYSTEMS AT ALL THE EXTERIOR 1ST FLOOR LEVEL GLAZED OPENINGS EXCEPT NEW EXTERIOR FIXED WINDOWS & IMPACT GLAZING
FOR KITCHEN ONLY.
F. ALTERNATE BID ITEM NO. 6: PROVIDE NEW 20'-0" WIDE (K-8 FORCE PROTECTION) FENCE SYSTEM) DOUBLE SWING GATE WITH MANUAL FUNCTION TO SOUTH SIDE OF POV PARKING. EXISTING DEAD MAN ANCHOR LAYOUT TO BE RE-CONFIGURED FOR NEW GATE. COMPLETE FUNCTIONAL INSTALLATION
REQUIRED.
G. ALTERNATE BID ITEM NO. 7: PROVIDE MILL AND OVERLAY OF THE NORTH & EAST POV PARKING LOT AS INDICATED IN THE ATTACHED CIVIL DRAWINGS.
H. ALTERNATE BID ITEM NO. 8: PROVIDE NEW DEHUMIDIFIER AND MECHANICAL AIR INSTALLED INTO THE TO THE EXISTING VAULT ROOM # 110 & #111.
SHEET NO.:
PROJECT NO.:
DATE:
SHEET TITLE:
DRAWN BY:
REVISIONS:
CONSULTING ENGINEERS
154A Whitaker Rd.
Lutz, Florida 33549
813.333.2103 www.balengineering.com
Registry No. 31211
TO THE BEST OF THE KNOWLEDGE OF
THE ENGINEERS AND ARCHITECTS,
SAID PLANS AND SPECIFICATIONS
COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODES AND THE
APPLICABLE MINIMUM FIRE SAFETY
STANDARDS
/1
/2
:1 :2
P
M
C U s e rs \A d a m
G o re c k i\ B
A L E n g in e e ri n g In c \B
A L E n g in e e ri n g In c In te rn a l
D o c u m e n ts
P ro je c ts
\2
\2
D M
A C
F M
O P a lm e tt o \W o rk in g
D ra w in g s \2
M
P
R
.r v t
AG
P0.1
NOTES, LEGENDS
AND SCHEDULES
T
H A
V E
W E
S T
P
A L M
E T
T O
F
L
1910.08
MARCH 30, 2026
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
N A
T
IO
N A
L G
U A
R D
A R
M O
R Y
D M
A C
F M
O
P A
L M
E T
T O
E S
P R
E N
O V
A T
IO
N
1 06-17-26 ADDENDUM 02
ACCEPTABLE MANUFACTURERS:
WOODFORD MODEL 24
HB-1 HOSE BIBB CAST BRASS CHROME FINISH WHEEL HANDLE HOSE BIBB WITH 3/4" MALE
HOSE THREAD AND ANTI-SIPHON VACUUM BREAKER.
1/2" N/A N/A
NOTE: PVC TRAPS MUST BE PROVIDED. ELKAY 36281C VOLTAGE SPIKE
LIMITER (SNUBBER) SHALL BE SPECIFIED TO AVOID ISSUES WITH GFI OUTLETS
TRIPPING.
ACCEPTABLE MANUFACTURERS:
ZURN Z1225
CARRIER (STUD WALL):
WATER COOLER SUPPORT SYSTEM WITH TOP AND BOTTOM PLATES,
COMPLETE WITH DURA-COATED RECTANGULAR STEEL UPRIGHTS WITH
WELDED FEET, CAST IRON ADJUSTABLE HEADERS, STEEL SLEEVES,
ALIGNMENT TRUSS AND MOUNTING FASTENERS.
ACCEPTABLE MANUFACTURERS:
ZURN Z1259
CARRIER (BLOCK WALL):
WATER COOLER SUPPORT WITH ADJUSTABLE DURA-COATED TOP AND
BOTTOM SUPPORT PLATES, COMPLETE WITH MOUNTING FASTENERS.
ACCEPTABLE MANUFACTURERS:
ELKAY MODEL NO. VRCTL8WSK
HALSEY
EWC-1 ELECTRIC WATER
COOLER ADA
COMPLIANT
WITH BOTTLE
FILLING STATION
(DOUBLE UNIT)
BI-LEVEL DRINKING FOUNTAIN WATER COOLER:
BI-LEVEL STAINLESS-STEEL BASIN WITH GREY STONE POWDER COATED
GALVANIZED STEEL CABINET WITH BOTTLE FILLING STATION, VANDAL
RESISTANT PUSHBUTTON ACTIVATION, 8.0 GPH COOLED TO 50 °F AT 370 WATTS,
5.0 FLA. UNIT SHALL INCORPORATE A MECHANICALLY OPERATED VALVE TO
MAINTAIN WATER STREAM WITHOUT POWER TO UNIT, AUTOMATIC 20 SECOND
SHUTOFF. INSTALL LOWER UNIT IN COMPLIANCE WITH CHILDREN ’S ADA...
1/2" N/A 2"
TD-1 TRENCH DRAIN 6" WIDE MODULAR TRENCH DRAIN WITH POLISHED NICKLE BRONZE TOP,
PROVIDE WITH DEEP SEAL TRAP. FIELD MEASURE EXISTING FOR EXACT
REQUIREMENTS. COORDINATE WITH ARCHITECTURAL DRAWINGS. PROVIDE
SECTIONS AS REQUIRED.
N/A N/A 3" U.N.O
EWH-3 ELECTRIC WATER
HEATER
TANKLESS WATER HEATER SHALL BE AN EEMAX MODEL NUMBER SPEX3208 WITH
A 3KW ELEMENT AT 208/1. UNIT SHALL HAVE ABS-UL 94 5VA RATED COVER. UNIT
SHALL ALLOW MOUNTING IN ANY ORIENTATION. ELEMENT SHALL BE
REPLACEABLE CARTRIDGE INSERT. ELEMENT SHALL BE IRON-FREE,
NICKEL-CHROME MATERIAL. UNIT SHALL HAVE REPLACEABLE FILTER IN THE
INLET CONNECTOR. UNIT SHALL INCLUDE AN INTEGRATED FLOW METER TO
ENSURE ACCURATE TURN-ON / TURN-OFF FLOW RATE. HEATER SHALL BE FITTED
WITH 3/8 ” COMPRESSION FITTINGS TO ELIMINATE THE NEED FOR SOLDERING.
MAXIMUM OPERATING PRESSURE OF 150 PSI. DIAGNOSTIC FEATURES TO
INCLUDE LED ERROR/FAULT INDICATOR. HEATER SHALL EMPLOY TECHNOLOGY
THAT ENGAGES UPON START-UP TO AVOID DRY-FIRE OCCURRENCE. HOT WATER
STORAGE TANKS PROHIBITED. UNIT SHALL BE EEMAX OR APPROVED EQUAL.
3/8" 3/8" N/A
EWH-1 &
EWH-2
ELECTRIC WATER
HEATER
THE HEATER(S) SHALL BE GOLD XI COMMERCIAL ELECTRIC MODEL NUMBER
DVE-120-27 AS MANUFACTURED BY A. O. SMITH WATER PRODUCTS COMPANY
OR EQUIVALENT. HEATER(S) SHALL BE RATED AT 27 KW 208V 3-PHASE, 60
CYCLE AC AS LISTED BY UNDERWRITERS ’ LABORATORIES. ALL MODELS MEET
NATIONAL SANITATION FOUNDATION NSF-5 REQUIREMENTS. WATER HEATER
SHALL HAVE LCD DISPLAY WITH BUILT-IN DIAGNOSTIC AND TROUBLESHOOTING
INFORMATION. TANK(S) SHALL BE 119 GALLON CAPACITY WITH 160 [ASME] PSI
WORKING PRESSURE AND EQUIPPED WITH DUAL EXTRUDED HIGH-DENSITY
ANODES. ALL INTERNAL SURFACES OF THE HEATER(S) EXPOSED TO WATER
SHALL BE GLASS-LINED WITH AN ALKALINE BOROSILICATE COMPOSITION THAT
HAS BEEN FUSED TO STEEL BY FIRING AT A TEMPERATURE RANGE OF 1400 °F
TO 1600 °F. INTERNAL POWER CIRCUIT FUSING SHALL BE PROVIDED. ELEMENT
OPERATION SHALL BE LINEAR SEQUENCING THROUGH INDIVIDUAL MAGNETIC
CONTACTORS. CONTROL CIRCUIT SHALL BE FACTORY FUSED AND INCLUDE AN
IMMERSION THERMISTOR TEMPERATURE PROBE WITH BUILT IN ECO
CONTROL. CONTROL CABINET AND JACKET SHALL BE OF BAKED ENAMEL F
FINISH AND SHALL PROVIDE FULL SIZE CONTROL AND ELEMENT
COMPARTMENT FOR COMPLETE SERVICE AND MAINTENANCE PERFORMANCE
THROUGH FRONT HINGED COMPARTMENT DOOR, AND ENCLOSE TANK WITH
FOAM INSULATION. 1 1/4 ” INLET AND OUTLET CONNECTION SHALL BE
PROVIDED. THE HEATER TANK SHALL HAVE A THREE YEAR LIMITED WARRANTY
AND CONTROLS AND ACCESSORIES SHALL HAVE A ONE YEAR LIMITED
WARRANTY AS OUTLINED IN THE WRITTEN WARRANTY. FULLY ILLUSTRATED
INSTRUCTION MANUAL TO BE INCLUDED. FOR MULTIPLE INSTALLATION,
FACTORY BUILT MANIFOLD KITS FOR 2 HEATER INSTALLATION SHALL BE
PROVIDED. MEETS OR EXCEEDS THE THERMAL EFFICIENCY AND STANDBY
LOSS REQUIREMENTS OF THE U.S. DEPARTMENT OF ENERGY AND CURRENT
EDITION OF ASHRAE/IES 90.1.
1-1/4" 1-1/4" N/A
SS-1 SERVICE SINK BOWL:
EXISTING TO REMAIN
1/2" 1/2" 3"
SHOWER ARM:
1/2" IPS MALE THREADS WITH CHROME FINISH AND CHROME FLANGE. EQUAL
TO MOEN MODEL NO. S122.
SHOWER HEAD:
METAL CONSTRUCTION WITH CHROME PLATED FINISH, VANDAL RESISTANT
SHOWER HEAD WITH EASY CLEANING RUBBER NOZZLES. EQUAL TO MOEN
WATERSENSE CERTIFIED NO. 9263EP15.
VALVE:
PROVIDE BRASS VALVE WITH 1/4 TURN INTEGRAL STOPS ON EACH INLET.
METAL HANDLE CONSTRUCTION WITH CHROME FINISH EQUAL TO MOEN
MODEL NO. U8350
DRAIN:
EXISTING TO REMAIN
SH-1 &
SH-2
SHOWER ENCLOSURE:
SEE ARCHITECTURAL
1/2" 1/2" 2"
EWC-1 ELECTRIC WATER
COOLER
EXISTING TO REMAIN 1/2" N/A 1-1/4"
PROVIDE LAV SHIELD RIGID ENCLOSURE TO COMPLY WITH ADA
REQUIREMENTS. COORDINATE TRUEBRO LAV SHIELD MODEL WITH LAVATORY
BOWL MANUFACTURER.
SUPPLY STOPS:
TWO REQUIRED, 1/2" x 3/8" O.D. HEAVY CAST BRASS ANGLE STOP, ANNEALED
VERTICAL TUBES, CHROME PLATED CAST BRASS SET SCREW ESCUTCHEON,
CHROME PLATED BRASS NIPPLE TO WALL. EQUAL TO McGUIRE MODEL
LFHST09LK OR EQUAL.
TAILPIECE:
1-1/4" INLET WITH 1/2" TRAP PRIMER OUTLET WHERE INDICATED TO PROVIDE
PRIMER WATER FOR FLOOR DRAIN SEE PLANS. STANDARD TAILPIECE TO BE
UTILIZED IN LOCATIONS NOT SERVING FLOOR DRAINS. EQUAL TO OATEY PART
NO. 831-1.
P-TRAP:
1-1/4" INLET AND 1-1/2" OUTLET POLISHED CHROME PLATED CAST BRASS BODY
ADJUSTABLE P-TRAP WITHOUT CLEANOUT, WITH 17-GAUGE SEAMLESS
TUBULAR WALL BEND, CAST BRASS SLIP NUTS AND CHROME PLATED SET
SCREW ESCUTCHEON. EQUAL TO OATEY PART NO. 700-1.
DRAIN: GRID TYPE STRAINER WITH 4" TAIL PIECE.
FAUCET:
TWO-HANDLE ADA COMPLIANT, 4" CENTERSET MOUNTING, CHROME PLATED
SOLID BRASS CONSTRUCTION, VANDAL RESISTANT, 1/2" IPS SUPPLY SHANKS.
EQUAL TO MOEN MODEL 8215SMF12 OR EQUAL
L-1 LAVATORY
HANDICAPPED OR
NON-HANDICAPPED
BOWL:
EXISTING TO BE REMOVED AND RE-INSTALLED
1/2" 1/2" 1-1/4"
FLUSH VALVE:
EXPOSED, QUIET DIAPHRAGM-TYPE, CHROME PLATED FLUSHOMETER VALVE
WITH A POLISHED EXTERIOR. ADA COMPLIANT WITH A NON-HOLD OPEN AND
NO LEAK HANDLE FEATURE. POSITION HANDLE TO RIGHT SIDE. EQUAL TO
ZURN MODEL Z6003AV.
UR-1 URINAL
NON-HANDICAPPED
URINAL:
EXISTING TO REMAIN
3/4" N/A 2"
SEAT:
ELONGATED, STANDARD WHITE, OPEN FRONT TOILET SEAT, LESS COVER, WITH
CHECK HINGE. EQUAL TO BEMIS MODEL 1955CT 000.
FLUSH VALVE:
EXPOSED, QUIET DIAPHRAGM-TYPE, CHROME PLATED FLUSHOMETER VALVE
WITH A POLISHED EXTERIOR. ADA COMPLIANT WITH A NON-HOLD OPEN AND
NO LEAK HANDLE FEATURE. DUAL FLUSH ACTION, POSITION HANDLE TO WIDE
SIDE OF ROOM. EQUAL TO ZURN MODEL Z6000AV.
WC-1 &
WC-2
WATER CLOSET
NON-HANDICAPPED
/ HANDICAPPED
WATER CLOSET:
EXISTING TO REMAIN
1" N/A 4"
ID NAME DESCRIPTION CW HW SAN
220000
P PLUMBING FIXTURE SCHEDULE
THIS ITEM HAS BEEN ELECTRONICALLY
SIGNED AND SEALED BY BRYANT A. LYLE ON
JUNE 16, 2026 USING A DIGITAL SIGNATURE.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
| Sheets |
| P0.1 - NOTES, LEGENDS AND SCHEDULES |
| 2026-06-16T17:52:42-0400 | |
| Bryant A Lyle |
File details come from the government source that posted it. Updated .