224004 Palmetto_100% ADD 02 PLUMBING_SS.pdf

PDF 1 MB Posted

Attached to
224004 Palmetto Revamp
Solicitation number
ITB-15884
Issued by
St. Johns County, Florida

About this file

This is a plumbing specification document for the Palmetto Readiness Center renovation project (Project No. 224004) being executed by the State of Florida, Department of Military Affairs, with design services provided by BAL Engineering, Inc. and Renker Eich Park Architects. The scope of work encompasses replacement of fixture trim packages for existing lavatories, water closets, urinals, and sinks; refresh of existing showers with new valves, arms, and shower heads; replacement of existing shower trench drains; and replacement of existing electric tank-type water heaters with a hot water recirculation loop system. The work must comply with the 8th Edition (2023) Florida Building Code, applicable NFPA standards, ASHRAE guidelines, and SMACNA specifications. All plumbing materials, including PVC and cast iron drainage piping, copper and CPVC water piping, and isolation valves, must meet specified ASTM standards. The project includes detailed fixture schedules specifying acceptable manufacturers for components such as electric water coolers (Elkay VRCTL8WSK), tankless electric water heaters (EEMAX SPEX3208), commercial electric water heaters (A.O. Smith Gold XI DVE-120-27), and shower fixtures (Moen brand items). Hot water piping requires minimum one-inch fiberglass insulation with white ASJ or three-quarter-inch closed-cell foam split insulation. The project includes eight alternate bid items covering parking improvements, LED lighting upgrades, exterior facade refinishing, glazing replacement, fence installation, parking lot overlay, and dehumidifier installation in vault rooms.

The specifications establish comprehensive material and workmanship requirements, with all plumbing fixtures, pipes, and fittings warranted for one year after substantial completion. The contractor is responsible for coordinating all trade schedules, ensuring fixed work such as ductwork and plumbing is installed prior to easily relocable systems, and maintaining minimum clearances for service access, including 18 inches for wall cleanouts and 12-by-12-inch minimum locking access panels for valve access. Fire-rated penetrations must be sealed to maintain assembly ratings, and water hammer arrestors and air chambers must be provided at appropriate fixture connections. The specifications include detailed plumbing fixture schedules identifying connection sizes, trap configurations, and installation requirements for lavatories, water closets, urinals, service sinks, showers, and electric water coolers, with many existing fixtures to be removed and reinstalled or remain in place. The project document was prepared as 100% Construction Documents dated March 30, 2026, with Addendum 02 providing acceptable manufacturer specifications and additional technical requirements for specialty items.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FCO

VTR

WCO

GENERAL PLUMBING NOTES

P

220000

1. IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC AND SHOULD NOT BE SCALED.

2. INTENT OF THESE NOTES AND PLUMBING NOTES ON DRAWINGS IS TO CLARIFY THE SCOPE OF WORK.

3. THE CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL DAMAGE TO OWNER'S PROPERTY OR OTHER UNCOORDINATED TRADES

DURING THE COURSE OF CONSTRUCTION.

4. THE CONTRACTOR IS RESPONSIBLE FOR ALL TRADES INSTALLATION SCHEDULES. FIXED WORK SUCH AS DUCTWORK AND

PLUMBING SHALL BE INSTALLED PRIOR TO ANY TRADE WORK THAT CAN BE EASILY RELOCATED OR OFFSET SUCH AS ELECTRIC

CONDUITS, SMALL WATER LINES, ETC.

5. CONTRACTOR SHALL NOTIFY ARCHITECT/ENGINEER IN WRITING OF ANY CONFLICTS BETWEEN THE TRADES.

6. IN THE EVENT OF A CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND THE CODES, THE CODES SHALL TAKE PRECEDENCE.

7. CONTRACTOR SHALL PROVIDE ANY NECESSARY ITEMS NOT EXPRESSLY MENTIONED IN THE CONTRACT DOCUMENTS NEEDED TO

PROVIDE A COMPLETE PLUMBING SYSTEM.

8. UNLESS OTHERWISE NOTED, ALL PIPING SHALL BE LOCATED IN CONCEALED SPACES. PROVIDE MIN. 12"x12" LOCKING ACCESS

PANELS IN WALLS AND HARD CEILINGS FOR ACCESS TO VALVES.

9. PENETRATIONS FOR PIPES THROUGH ASSEMBLIES (FLOORS, ROOF, WALLS, PARTITIONS, ETC) WITH A REQUIRED FIRE RESISTANCE

RATING SHALL BE SEALED TO THE PENETRATING MEMBER IN AN APPROVED MANNER WHICH MAINTAINS THE REQUIRED FIRE

RESISTANCE RATING OF THE ASSEMBLY.

10. ALL PLUMBING FIXTURES, PIPES AND FITTINGS SHALL BE WARRANTED FOR 1 YEAR AFTER DATE OF SUBSTANTIAL COMPLETION.

11. PROVIDE WATER HAMMER ARRESTORS SIZE PDI "A" AT EACH PLUMBING FIXTURE CONNECTION INCORPORATING QUICK CLOSING

FAUCETS OR VALVES. PROVIDE AIR CHAMBERS AT ALL REMAINING FIXTURES WITHOUT SELF CLOSING VALVES.

12. WALL CLEANOUTS SHALL MAINTAIN A MINIMUM 18" CLEARANCE FOR SERVICE ACCESS.

13. ALL DRAINAGE AND VENT PIPING SHALL BE:

A. ALL MATERIALS SHALL BE NEW, FREE OF DAMAGE AND MEET THE FOLLOWING REQUIREMENTS:

a. PVC PIPE: SHALL BE MARKED AS MEETING ASTM D 2665 SPECIFICATION FOR PVC PLASTIC DRAIN, WASTE, AND

VENT PIPE AND FITTINGS AND/OR ASTM D 1785 SPECIFICATION FOR PVC PLASTIC PIPE, SCHEDULES 40, 80 AND 120.

b. CAST IRON: SHALL BE MARKED AS MEETING ASTM A888 OR CISPI 301 FOR CAST IRON PIPING

14. ALL DOMESTIC HOT AND COLD WATER PIPING SHALL BE:

A. ALL MATERIALS SHALL BE NEW, FREE OF DAMAGE AND MEETING THE FOLLOWING REQUIREMENTS:

a. COPPER PIPE: SHALL BE TYPE 'L' HARD TEMPER COPPER TUBING, ASTM B-88, WROUGHT COPPER FITTINGS, 95/5

TIN/ANTIMONY, NO-LEAD SOLDER.

b. CPVC PIPE: SHALL BE COPPER TUBE SIZE CPVC PIPE, ASTM 2846 WITH ASTM F 493 SOLVENT CEMENTS FOR

JOINING CPVC PIPE AND SOCKET FITTINGS.

15. ALL PLUMBING ISOLATION VALVES SHALL BE:

A. 1/2" - 3" SHALL BE QUARTER TURN , FULL PORT, ONE-PIECE BALL VALVES, BLOW OUT PROOF STEM, BRONZE BODY, STAINLESS STEEL BALL, TFE SEATS, EXTENDED NECK SUITABLE FOR INSULATION, SOLDERED, SCREWED OR

COMPRESSION FITTINGS. PUSH-ON FITTINGS WILL NOT BE ACCEPTED.

B. 4" - 12" SHALL BE RESILIENT WEDGE GATE VALVES, FLANGED CONNECTIONS, DUCTILE IRON AWWA/ANSI C515 BODY, DUCTILE IRON WEDGE WITH EPDM RUBBER SEALS, MUST BE NSF 61 AND NSF 372 LISTED.

16. INSULATION FOR HOT WATER PIPING:

A. MIN. 1" THICK FIBERGLASS INSULATION WITH WHITE ASJ. PREFORMED FITTINGS SHALL BE UTILIZED AT ALL STANDARD

ELBOWS AND FITTINGS.

B. MIN. 3/4" THICK CLOSED CELL FOAM SPLIT INSULATION.

CODE COMPLIANCE

P

220000

1. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE 8TH EDITION (2023) FLORIDA BUILDING CODE

A. BUILDING EDITION

B. EXISTING BUILDING EDITION

C. MECHANICAL EDITION

D. PLUMBING EDITION

E. FUEL GAS EDITION

F. ENERGY EFFICIENCY EDITION

G. 8TH EDITION (2023) FLORIDA FIRE PREVENTION CODE.

2. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

A. NFPA-1 NATIONAL FIRE CODE WITH FLORIDA MODIFICATIONS

B. NFPA-70 NATIONAL ELECTRIC CODE

C. NFPA-72 NATIONAL FIRE ALARM CODE

D. NFPA-101 NATIONAL LIFE SAFETY CODE

3. AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS, INC. (ASHRAE)

4. SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION (SMACNA)

SCOPE OF WORKP

220000

1. REPLACE EXISTING FIXTURE TRIM PACKAGES WITH NEW FOR EXISTING LAVATORIES, WATER

CLOSETS, URINALS AND SINKS.

2. REFRESH EXISTING SHOWERS WITH NEW VALVES, ARMS AND SHOWER HEADS.

3. REPLACE EXISTING SHOWER TRENCH DRAIN.

4. REPLACE EXISTING ELECTRIC TANK TYPE WATER HEATERS.

COTG

CO

HOT WATER RECIRC. LOOP

COLD WATER

DRAWING SYMBOL DESCRIPTION DRAWING SYMBOL

ABBREVIATION

HOT WATER (110°F)

UP TO LEVEL ABOVE

NOT IN CONTRACT

WATER CLOSET

URINAL

SERVICE SINK

FLOOR SINK

HOSE BIBB

ROOF HYDRANT

ELECTRIC WATER HEATER

GAS WATER HEATER

2-WAY CLEAN-OUT TO GRADE

STORM PIPING

SANITARY PIPING BELOW

SANITARY PIPING

KEYED NOTE

VENT PIPING

UNION

REVISION NOTE

PRESSURE GAUGE WITH

GAUGE COCK

HOSE BIBB OR WALL HYDRANT

THERMOMETER

FLOOR DRAIN

ROOF DRAIN

FLOOR SINK

WALL CLEAN OUT

VENT THRU ROOF

FLOOR CLEAN OUT

TWO-WAY CLEAN OUT

TO

GRADE

END OF PIPE CLEAN OUT

FLEXIBLE CONNECTION

GLOBE VALVE

PLUG VALVE

CHECK VALVE

Y-STRAINER WITH

DRAIN

VALVE

Y-STRAINER

BALL VALVE

ANGLE VALVE

GATE VALVE

PIPE DOWN

PIPE UP

HOT WATER RETURN LOOP

TEE FITTING PIPE UP

TEE FITTING PIPE DOWN

DOMESTIC HOT WATER

DOMESTIC COLD WATER

NEW EQUIPMENT

HB

VALVE

CONDENSATE DRAIN

SANITARY SEWER

ABBREVIATION

STORM WATER

DOWN TO LEVEL BELOW

UNLESS NOTED OTHERWISE

LAVATORY

SINK

FLOOR DRAIN

ROOF DRAIN

WALL HYDRANT

1/2" TRAP PRIMER

ELECTRIC WATER COOLER

DRINKING FOUNTAIN

HUB DRAIN

THE STANDARD SYMBOLS AND ABBREVIATION ABOVE MAY NOT BE USED. CONTRACTOR IS ONLY RESPONSIBLE FOR SYMBOLS CONTAINED WITHIN THE DOCUMENTS USED TO IDENTIFY REQUIRED SCOPE OF WORK.

DESCRIPTION

DESCRIPTIONDESCRIPTION

SUPPLY RETURN

COTG

GWH

HB

EWH

RH

FS

SS

NIC

UR

WC

UP

HWR

CW

HW

DN

CD

SS

ST

UNO

HD

DF

WH

EWC

TP

RD

FD

S

L

S R

LEGEND

P

220000

ABBREVIATIONS

EXISTING[E]

NEW[N]

REPLACE[R]

DEMOLISH[D]

DEMOLITION NOTE SYSTEM NOTE##

ALTERNATE BID ITEMS

A. ALTERNATE BID ITEM NO. 1: PARKING AREA - STORMWATER MITIGATION, ASPHALT MILLING, AND RESURFACE. CONNECT MAIN ARMORY ROOF DRAINS TO

UNDERGROUND STORM DRAIN SYSTEM.

B. ALTERNATE BID ITEM NO. 2: UPGRADE MAIN ARMORY BUILDING INTERIOR AND EXTERIOR LIGHTING TO LED TO INCLUDE UNIT SIGN AND FLAGPOLE.

C. ALTERNATE BID ITEM NO. 3: REFINISH AND REPAINT COMPLETE EXTERIOR STUCCO / BRICK FACADE WITH UP TO 4 COLOR SCHEME. INCLUDE THE PAINTING OF ALL

EXTERIOR HM DOORS AND FRAMES INCLUDING ALL INSIDE AND OUTSIDE FACES.

D. ALTERNATE BID ITEM NO. 4: COMPLETE GLAZING REPLACEMENT OF ALL EXISTING LAMINATED IMPACT GLAZING IN EXISTING ALUMINUM WINDOW FRAME SYSTEMS AT

THE EXTERIOR CLERESTORY LEVEL.

E. ALTERNATE BID ITEM NO. 5: COMPLETE GLAZING REPLACEMENT OF ALL EXISTING LAMINATED IMPACT GLAZING IN ALL EXISTING ALUMINUM WINDOW FRAME SYSTEMS AT ALL THE EXTERIOR 1ST FLOOR LEVEL GLAZED OPENINGS EXCEPT NEW EXTERIOR FIXED WINDOWS & IMPACT GLAZING

FOR KITCHEN ONLY.

F. ALTERNATE BID ITEM NO. 6: PROVIDE NEW 20'-0" WIDE (K-8 FORCE PROTECTION) FENCE SYSTEM) DOUBLE SWING GATE WITH MANUAL FUNCTION TO SOUTH SIDE OF POV PARKING. EXISTING DEAD MAN ANCHOR LAYOUT TO BE RE-CONFIGURED FOR NEW GATE. COMPLETE FUNCTIONAL INSTALLATION

REQUIRED.

G. ALTERNATE BID ITEM NO. 7: PROVIDE MILL AND OVERLAY OF THE NORTH & EAST POV PARKING LOT AS INDICATED IN THE ATTACHED CIVIL DRAWINGS.

H. ALTERNATE BID ITEM NO. 8: PROVIDE NEW DEHUMIDIFIER AND MECHANICAL AIR INSTALLED INTO THE TO THE EXISTING VAULT ROOM # 110 & #111.

SHEET NO.:

PROJECT NO.:

DATE:

SHEET TITLE:

DRAWN BY:

REVISIONS:

CONSULTING ENGINEERS

154A Whitaker Rd.

Lutz, Florida 33549

813.333.2103 www.balengineering.com

Registry No. 31211

TO THE BEST OF THE KNOWLEDGE OF

THE ENGINEERS AND ARCHITECTS,

SAID PLANS AND SPECIFICATIONS

COMPLY WITH THE APPLICABLE

MINIMUM BUILDING CODES AND THE

APPLICABLE MINIMUM FIRE SAFETY

STANDARDS

/1

/2

:1 :2

P

M

C U s e rs \A d a m

G o re c k i\ B

A L E n g in e e ri n g In c \B

A L E n g in e e ri n g In c In te rn a l

D o c u m e n ts

P ro je c ts

\2

\2

D M

A C

F M

O P a lm e tt o \W o rk in g

D ra w in g s \2

M

P

R

.r v t

AG

P0.1

NOTES, LEGENDS

AND SCHEDULES

T

H A

V E

W E

S T

P

A L M

E T

T O

F

L

1910.08

MARCH 30, 2026

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

N A

T

IO

N A

L G

U A

R D

A R

M O

R Y

D M

A C

F M

O

P A

L M

E T

T O

E S

P R

E N

O V

A T

IO

N

1 06-17-26 ADDENDUM 02

ACCEPTABLE MANUFACTURERS:

WOODFORD MODEL 24

HB-1 HOSE BIBB CAST BRASS CHROME FINISH WHEEL HANDLE HOSE BIBB WITH 3/4" MALE

HOSE THREAD AND ANTI-SIPHON VACUUM BREAKER.

1/2" N/A N/A

NOTE: PVC TRAPS MUST BE PROVIDED. ELKAY 36281C VOLTAGE SPIKE

LIMITER (SNUBBER) SHALL BE SPECIFIED TO AVOID ISSUES WITH GFI OUTLETS

TRIPPING.

ACCEPTABLE MANUFACTURERS:

ZURN Z1225

CARRIER (STUD WALL):

WATER COOLER SUPPORT SYSTEM WITH TOP AND BOTTOM PLATES,

COMPLETE WITH DURA-COATED RECTANGULAR STEEL UPRIGHTS WITH

WELDED FEET, CAST IRON ADJUSTABLE HEADERS, STEEL SLEEVES,

ALIGNMENT TRUSS AND MOUNTING FASTENERS.

ACCEPTABLE MANUFACTURERS:

ZURN Z1259

CARRIER (BLOCK WALL):

WATER COOLER SUPPORT WITH ADJUSTABLE DURA-COATED TOP AND

BOTTOM SUPPORT PLATES, COMPLETE WITH MOUNTING FASTENERS.

ACCEPTABLE MANUFACTURERS:

ELKAY MODEL NO. VRCTL8WSK

HALSEY

EWC-1 ELECTRIC WATER

COOLER ADA

COMPLIANT

WITH BOTTLE

FILLING STATION

(DOUBLE UNIT)

BI-LEVEL DRINKING FOUNTAIN WATER COOLER:

BI-LEVEL STAINLESS-STEEL BASIN WITH GREY STONE POWDER COATED

GALVANIZED STEEL CABINET WITH BOTTLE FILLING STATION, VANDAL

RESISTANT PUSHBUTTON ACTIVATION, 8.0 GPH COOLED TO 50 °F AT 370 WATTS,

5.0 FLA. UNIT SHALL INCORPORATE A MECHANICALLY OPERATED VALVE TO

MAINTAIN WATER STREAM WITHOUT POWER TO UNIT, AUTOMATIC 20 SECOND

SHUTOFF. INSTALL LOWER UNIT IN COMPLIANCE WITH CHILDREN ’S ADA...

1/2" N/A 2"

TD-1 TRENCH DRAIN 6" WIDE MODULAR TRENCH DRAIN WITH POLISHED NICKLE BRONZE TOP,

PROVIDE WITH DEEP SEAL TRAP. FIELD MEASURE EXISTING FOR EXACT

REQUIREMENTS. COORDINATE WITH ARCHITECTURAL DRAWINGS. PROVIDE

SECTIONS AS REQUIRED.

N/A N/A 3" U.N.O

EWH-3 ELECTRIC WATER

HEATER

TANKLESS WATER HEATER SHALL BE AN EEMAX MODEL NUMBER SPEX3208 WITH

A 3KW ELEMENT AT 208/1. UNIT SHALL HAVE ABS-UL 94 5VA RATED COVER. UNIT

SHALL ALLOW MOUNTING IN ANY ORIENTATION. ELEMENT SHALL BE

REPLACEABLE CARTRIDGE INSERT. ELEMENT SHALL BE IRON-FREE,

NICKEL-CHROME MATERIAL. UNIT SHALL HAVE REPLACEABLE FILTER IN THE

INLET CONNECTOR. UNIT SHALL INCLUDE AN INTEGRATED FLOW METER TO

ENSURE ACCURATE TURN-ON / TURN-OFF FLOW RATE. HEATER SHALL BE FITTED

WITH 3/8 ” COMPRESSION FITTINGS TO ELIMINATE THE NEED FOR SOLDERING.

MAXIMUM OPERATING PRESSURE OF 150 PSI. DIAGNOSTIC FEATURES TO

INCLUDE LED ERROR/FAULT INDICATOR. HEATER SHALL EMPLOY TECHNOLOGY

THAT ENGAGES UPON START-UP TO AVOID DRY-FIRE OCCURRENCE. HOT WATER

STORAGE TANKS PROHIBITED. UNIT SHALL BE EEMAX OR APPROVED EQUAL.

3/8" 3/8" N/A

EWH-1 &

EWH-2

ELECTRIC WATER

HEATER

THE HEATER(S) SHALL BE GOLD XI COMMERCIAL ELECTRIC MODEL NUMBER

DVE-120-27 AS MANUFACTURED BY A. O. SMITH WATER PRODUCTS COMPANY

OR EQUIVALENT. HEATER(S) SHALL BE RATED AT 27 KW 208V 3-PHASE, 60

CYCLE AC AS LISTED BY UNDERWRITERS ’ LABORATORIES. ALL MODELS MEET

NATIONAL SANITATION FOUNDATION NSF-5 REQUIREMENTS. WATER HEATER

SHALL HAVE LCD DISPLAY WITH BUILT-IN DIAGNOSTIC AND TROUBLESHOOTING

INFORMATION. TANK(S) SHALL BE 119 GALLON CAPACITY WITH 160 [ASME] PSI

WORKING PRESSURE AND EQUIPPED WITH DUAL EXTRUDED HIGH-DENSITY

ANODES. ALL INTERNAL SURFACES OF THE HEATER(S) EXPOSED TO WATER

SHALL BE GLASS-LINED WITH AN ALKALINE BOROSILICATE COMPOSITION THAT

HAS BEEN FUSED TO STEEL BY FIRING AT A TEMPERATURE RANGE OF 1400 °F

TO 1600 °F. INTERNAL POWER CIRCUIT FUSING SHALL BE PROVIDED. ELEMENT

OPERATION SHALL BE LINEAR SEQUENCING THROUGH INDIVIDUAL MAGNETIC

CONTACTORS. CONTROL CIRCUIT SHALL BE FACTORY FUSED AND INCLUDE AN

IMMERSION THERMISTOR TEMPERATURE PROBE WITH BUILT IN ECO

CONTROL. CONTROL CABINET AND JACKET SHALL BE OF BAKED ENAMEL F

FINISH AND SHALL PROVIDE FULL SIZE CONTROL AND ELEMENT

COMPARTMENT FOR COMPLETE SERVICE AND MAINTENANCE PERFORMANCE

THROUGH FRONT HINGED COMPARTMENT DOOR, AND ENCLOSE TANK WITH

FOAM INSULATION. 1 1/4 ” INLET AND OUTLET CONNECTION SHALL BE

PROVIDED. THE HEATER TANK SHALL HAVE A THREE YEAR LIMITED WARRANTY

AND CONTROLS AND ACCESSORIES SHALL HAVE A ONE YEAR LIMITED

WARRANTY AS OUTLINED IN THE WRITTEN WARRANTY. FULLY ILLUSTRATED

INSTRUCTION MANUAL TO BE INCLUDED. FOR MULTIPLE INSTALLATION,

FACTORY BUILT MANIFOLD KITS FOR 2 HEATER INSTALLATION SHALL BE

PROVIDED. MEETS OR EXCEEDS THE THERMAL EFFICIENCY AND STANDBY

LOSS REQUIREMENTS OF THE U.S. DEPARTMENT OF ENERGY AND CURRENT

EDITION OF ASHRAE/IES 90.1.

1-1/4" 1-1/4" N/A

SS-1 SERVICE SINK BOWL:

EXISTING TO REMAIN

1/2" 1/2" 3"

SHOWER ARM:

1/2" IPS MALE THREADS WITH CHROME FINISH AND CHROME FLANGE. EQUAL

TO MOEN MODEL NO. S122.

SHOWER HEAD:

METAL CONSTRUCTION WITH CHROME PLATED FINISH, VANDAL RESISTANT

SHOWER HEAD WITH EASY CLEANING RUBBER NOZZLES. EQUAL TO MOEN

WATERSENSE CERTIFIED NO. 9263EP15.

VALVE:

PROVIDE BRASS VALVE WITH 1/4 TURN INTEGRAL STOPS ON EACH INLET.

METAL HANDLE CONSTRUCTION WITH CHROME FINISH EQUAL TO MOEN

MODEL NO. U8350

DRAIN:

EXISTING TO REMAIN

SH-1 &

SH-2

SHOWER ENCLOSURE:

SEE ARCHITECTURAL

1/2" 1/2" 2"

EWC-1 ELECTRIC WATER

COOLER

EXISTING TO REMAIN 1/2" N/A 1-1/4"

PROVIDE LAV SHIELD RIGID ENCLOSURE TO COMPLY WITH ADA

REQUIREMENTS. COORDINATE TRUEBRO LAV SHIELD MODEL WITH LAVATORY

BOWL MANUFACTURER.

SUPPLY STOPS:

TWO REQUIRED, 1/2" x 3/8" O.D. HEAVY CAST BRASS ANGLE STOP, ANNEALED

VERTICAL TUBES, CHROME PLATED CAST BRASS SET SCREW ESCUTCHEON,

CHROME PLATED BRASS NIPPLE TO WALL. EQUAL TO McGUIRE MODEL

LFHST09LK OR EQUAL.

TAILPIECE:

1-1/4" INLET WITH 1/2" TRAP PRIMER OUTLET WHERE INDICATED TO PROVIDE

PRIMER WATER FOR FLOOR DRAIN SEE PLANS. STANDARD TAILPIECE TO BE

UTILIZED IN LOCATIONS NOT SERVING FLOOR DRAINS. EQUAL TO OATEY PART

NO. 831-1.

P-TRAP:

1-1/4" INLET AND 1-1/2" OUTLET POLISHED CHROME PLATED CAST BRASS BODY

ADJUSTABLE P-TRAP WITHOUT CLEANOUT, WITH 17-GAUGE SEAMLESS

TUBULAR WALL BEND, CAST BRASS SLIP NUTS AND CHROME PLATED SET

SCREW ESCUTCHEON. EQUAL TO OATEY PART NO. 700-1.

DRAIN: GRID TYPE STRAINER WITH 4" TAIL PIECE.

FAUCET:

TWO-HANDLE ADA COMPLIANT, 4" CENTERSET MOUNTING, CHROME PLATED

SOLID BRASS CONSTRUCTION, VANDAL RESISTANT, 1/2" IPS SUPPLY SHANKS.

EQUAL TO MOEN MODEL 8215SMF12 OR EQUAL

L-1 LAVATORY

HANDICAPPED OR

NON-HANDICAPPED

BOWL:

EXISTING TO BE REMOVED AND RE-INSTALLED

1/2" 1/2" 1-1/4"

FLUSH VALVE:

EXPOSED, QUIET DIAPHRAGM-TYPE, CHROME PLATED FLUSHOMETER VALVE

WITH A POLISHED EXTERIOR. ADA COMPLIANT WITH A NON-HOLD OPEN AND

NO LEAK HANDLE FEATURE. POSITION HANDLE TO RIGHT SIDE. EQUAL TO

ZURN MODEL Z6003AV.

UR-1 URINAL

NON-HANDICAPPED

URINAL:

EXISTING TO REMAIN

3/4" N/A 2"

SEAT:

ELONGATED, STANDARD WHITE, OPEN FRONT TOILET SEAT, LESS COVER, WITH

CHECK HINGE. EQUAL TO BEMIS MODEL 1955CT 000.

FLUSH VALVE:

EXPOSED, QUIET DIAPHRAGM-TYPE, CHROME PLATED FLUSHOMETER VALVE

WITH A POLISHED EXTERIOR. ADA COMPLIANT WITH A NON-HOLD OPEN AND

NO LEAK HANDLE FEATURE. DUAL FLUSH ACTION, POSITION HANDLE TO WIDE

SIDE OF ROOM. EQUAL TO ZURN MODEL Z6000AV.

WC-1 &

WC-2

WATER CLOSET

NON-HANDICAPPED

/ HANDICAPPED

WATER CLOSET:

EXISTING TO REMAIN

1" N/A 4"

ID NAME DESCRIPTION CW HW SAN

220000

P PLUMBING FIXTURE SCHEDULE

THIS ITEM HAS BEEN ELECTRONICALLY

SIGNED AND SEALED BY BRYANT A. LYLE ON

JUNE 16, 2026 USING A DIGITAL SIGNATURE.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

Sheets
P0.1 - NOTES, LEGENDS AND SCHEDULES
2026-06-16T17:52:42-0400
Bryant A Lyle

File details come from the government source that posted it. Updated .