224004 Palmetto_100% ADD 02 CIVIL_SS.pdf

PDF 5 MB Posted

Attached to
224004 Palmetto Revamp
Solicitation number
ITB-15884
Issued by
St. Johns County, Florida

About this file

Construction Document Submittal for Palmetto ESP Renovation

This is a 100% construction document submittal prepared by Hamilton Engineering & Surveying, LLC for the Palmetto ESP Renovation project, a full facility sustainment initiative for the State of Florida Department of Military Affairs. The project involves comprehensive maintenance, repairs, and lifecycle replacement work for the National Guard Armory located at 1107 14th Avenue W, Palmetto, Florida 34221 (Manatee County, Tax Parcel 2804400059). Construction work includes mechanical equipment replacement (exhaust fans, dehumidifiers, mini-split HVAC units), electrical outlet upgrades, plumbing fixture installation, ADA-compliant improvements, window re-caulking and tinting, interior and exterior painting, flooring replacements, weather sealing on exterior doors, and site infrastructure improvements. The documents reference an estimated construction cost of $2,173,045.00. The construction documents comply with the 8th Edition 2023 Florida Building Code, 2020 NEC electrical standards, the 8th Edition 2023 Florida Fire Prevention Code, NFPA 2019 standards, and City of Palmetto specifications. Key deliverables include demolition plans, site plans, grading and drainage plans, general construction notes addressing erosion control, water quality management, utility installation standards, ADA accessibility requirements, and detailed specifications for concrete sidewalk, asphalt pavement, sanitary sewer, potable water, and irrigation systems.

The submittal contains six sheets of construction documents prepared as of July 10, 2025, with an addendum dated June 17, 2026, including detailed notes on pavement markings, traffic control signage, utility separation requirements, and as-built documentation procedures. All construction work must comply with City of Palmetto standards, Florida Department of Environmental Protection requirements, and Florida Department of Transportation standards. The contractor is responsible for establishing accurate grade elevations referenced to the North American Vertical Datum 1988 (NAVD88), maintaining certified as-built records including coordinate data in State Plane Coordinates, and compliance with all federal, state, and local environmental protection regulations. Specific construction requirements address stormwater management, sediment control, utility locating (811 notification required), tree preservation, erosion control measures, handicap accessibility compliance, pipe material specifications (PVC, ductile iron, HDPE), water main pressure testing, and sanitary sewer slope minimums.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOR:

PALMETTO ESP RENOVATION

STATE OF FLORIDA

DEPARTMENT OF MILITARY AFFAIRS

82 MARINE STREET

ST. AUGUSTINE, FLORIDA 32086

OWNER

RENKER EICH PARKS ARCHITECTS

ATTN: RICHARD HEADLAND

1609 DR. MARTIN LUTHER KING JR. STREET N.

ST. PETERSBURG, FLORIDA 33704

P:(727) 821-2986 rheadland@reparch.com

ARCHITECT

LEGAL DESCRIPTION

HAMILTON ENGINEERING

& SURVEYING, LLC

ATTN: LUCAS CARLO, PE

3409 W LEMON STREET

TAMPA, FLORIDA 33609

(813) 250-3535 lucasc@hamiltonengineering.us

ENGINEER/SURVEYOR

P R

O

FES S ION ENGI N

EE

R

A L

I ENCL SE

NO. 61636

LUCAS CARLO

LF

O R I D A

STATE OF

This item has been digitally signed and sealed by Lucas Carlo, PE on the date adjacent to the seal.

Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.

VICINITY MAP

NTS

N

Call 811 or visit sunshine811.com two full business days before digging to have buried facilities locared and marked.

Check positive response codes before you dig!

SHEET INDEX

SHEET DWG No SHEET TITLE

1 C1.1 COVER SHEET

2 C2.1 GENERAL CONSTRUCTION NOTES

3 C3.1 DEMOLITION PLAN

4 C4.1 SITE PLAN

5 C5.1 GRADING & DRAINAGE PLAN

6 C6.1 DETAILSPROJECT LOCATION

100% CONSTRUCTION DOCUMENT SUBMITTAL

PALMETTO, FLORIDA 34221

SECTION 15, TOWNSHIP 34S, RANGE 17E

1107 14TH AVENUE W

TH

A

VE

W

DMA CFMO #224004

TAX PARCEL NUMBER: 2804400059

2/ 5/

:1

6:

P M

Au to de sk

D oc s:

//1

0.

N

G A

D ad e C ity /1

0.

D

M A

C

FM

O D

AD

E

C

IT

Y

ES

P R

EN

O

VA

TI

O N

S.

rv t

C1.1

0%

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IT

TA

L

10TH ST W

NOTE:

ALL CONSTRUCTION WILL COMPLY WITH THE 8TH EDITION 2023

FLORIDA BUILDING CODE FOR BUILDING, PLUMBING, MECHANICAL

AND ACCESSIBILITY. ELECTRICAL CODE 2020 NEC, THE 8TH

EDITION 2023 FLORIDA FIRE PREVENTION CODE AND NFPA 2019.

3409 W LEMON ST

TAMPA, FL 33609

TEL: 8I3.250.3535

775 WARNER LANE

ORLANDO, FL 32803

TEL: 407.362.5929www.HamiltonEngineering.US

LB #7013 CA #8474

SHEET NO.:

PROJECT NO.:

DATE:

SHEET TITLE:

DRAWN BY:

REVISIONS:

RG

1910.09

JULY 10, 2025

PA

LM

ET

TO

E

SP

R

EN

O

VA

TI

O

N

4T

H A

VE

W

, P

AL

M

ET

TO

, F

L

N

AT

IO

N

AL

G

U

AR

D A

R M

O R

Y

D M

A C

FM

O

4ALL OF BLK 3 LOTS 1,2,3,4,12,13, 14 BLK 4 LOTS 1,2,3,12,13,14 BLK 7 ALL OF BLK 8 LESS LOTS

5,6,7 RESUB OF JACKSON FACTORY SURVEY, TOGETHER WITH THE FOLLOWING VACATED

STREETS & ALLEYS: THAT PART OF 11TH ST LYING BETWEEN ABOVE DESC PROPERTY;

ALLEY BETWEEN LOTS 1,2,3 & LOTS 12,13,14 BLK 4; N 1/2 ALLEY BETWEEN LOTS 4 & 11 BLK 4;

ALLEY BETWEEN LOTS 1,2,3 & LOTS 12,13,14 BLK 7; ALL VACATED BY RESOLUTION REC IN OR

1298 P 1977, ALSO TOGETHER WITH VACATED STREETS AND ALLEYWAY VACATED BY

RESOLUTION 62-2 ATTACHED TO AFFADAVIT REC IN OR 2303 PG 1114 DESC AS FOLLOWS:

THAT PORTION OF LEE ST BETWEEN BOULEVARD AND BARRY AVE BOUNDED ON THE E BY

LOTS 8 & 9, BLK 3 & LOT 4 OF BLK 8 & BOUNDED ON THE W BY LOTS 1 & 14 OF BLK 4 AND

LOTS 1 & 14 OF BLK 7, THAT PORTION OF SPEAR AVE LYING BETWEEN THE FOLL LOTS; LOT

12 THROUGH 14 OF BLK 4, LOTS 9 THROUGH 16 OF BLK 3 ON THE N & LOTS 1 THROUGH 3 OF

BLK 7, & LOTS 1 THROUGH 4 OF BLK 8 ON THE S, THAT PORTION OF THE ALLEYWAY LYING

BETWEEN THE FOLL LOTS: LOTS 1 THROUGH 8 BLK 3 & LOTS 1 THROUGH 3 OF BLK 4 ON THE

N & LOTS 9 THROUGH 16 OF BLK 3 & LOTS 12 THROUGH 14 OF BLK 4 ON THE S, THAT

PORTION OF THE ALLEYWAY LYING BETWEEN THE FOLL LOTS: LOT 1, 2 & 3 OF BLK 7 ON THE

N & LOTS 12,13 & 14 OF BLK 7 ON THE S, LESS THAT PART PREVIOUSLY VACATED BY

RESOLUTION 90-11 REC IN OR 1298 PG 1977 LESS THAT PART INCLUDED IN OR 2309/6867

DESC AS FOLLOWS: A PORTION OF BLKS 3,4,5, 6,7 & 8 RE-PLAT OF JACKSON FACTORY SUB, AS REC IN PB 1, PG 317 PRMCF, ALG WITH THE VACATED STREETS & ALLEYS VACATED BY

RES 90-11, AS REC IN ORB 1298 PG 1977 & IN ORB 1569 PG 3497 & BY ORD NO.09-993 REC IN ORB 2301 PG 1057 & BY RES 62-2 AS REC IN ORB 2303 PG 1114 PRMCF, LYING WITHIN THE

FOLLOWING DESC PARCEL BDRY: COM AT THE SW COR OF LOT 8, BLK 6, RE-PLAT OF

JACKSON FACTORY SUB, AS REC IN PB 1 PG 317 PRMCF, SD PT BEING THE PI OF THE N R/W LN OF 10TH ST W & THE E R/W LN OF 17TH AVE W; TH N 00 DEG 02 MIN 07 SEC W, ALG SD E R/W LN, A DIST OF 341.14 FT FOR A POB; TH CONT N 00 DEG 02 MIN 07 SEC W, ALG SD R/W LN, A DIST OF 265.50 FT TO THE PI OF SD R/W LN & THE S R/W N OF 12TH ST W; TH S 89 DEG 55 MIN 39 SEC E, ALG SD R/W N, A DIST OF 856.48 FT; TH S 00 DEG 11 MIN 21 SEC E, 606.64 FT TO A PT ON THE AFOREMENTIONED N R/W LN OF 10TH ST W; TH N 89 DEG 55 MIN 39 SEC W, ALG SD R/W LN, A DIST OF 55.00 FT; TH N 00 DEG 11 MIN 21 SEC W, 350.00 FT; TH N 89 DEG 55 MIN

39 SEC W, 166.00 FT; TH S 00 DEG 11 MIN 21 SEC E, 350.00 FT TO A PT ON THE

AFOREMENTIONED N R/W LN OF 10TH ST W; TH N 89 DEG 55 MIN 39 SEC W, ALG SD N R/W LN, A DIST OF 367.10 FT; TH N 00 DEG 02 MIN 07 SEC W, 146.64 FT; TH N 31 DEG 07 MIN 22 SEC W,

128.25 FT; TH N 00 DEG 04 MIN 22 SEC E, 154.79 FT; TH N 89 DEG 55 MIN 38 SEC W, 60.00 FT;

TH S 00 DEG 04 MIN 22 SEC W, 70.00 FT; TH N 89 DEG 55 MIN 39 SEC W, 143.94 FT TO THE POB.

ALSO LESS THAT PART INCLUDED IN OR 2309/6943 DESC AS FOLLOWS: A PORTION OF BLKS 4

BLK 7, RE-PLAT OF JACKSON FACTORY SUB, AS REC IN PB 1, PG 317 PRMCF, TOGETHER

WITH THAT PORTION OF THE VACATED ALLEY, VACATED BY RES 90-11, REC IN ORB 1298 PG

1977 & IN ORB 1569 PG 3497 PRMCF, LYING WITHIN THE FOLLOWING DESC PARCEL BDRY:

COM AT THE SW COR OF LOT 8, BLK 6, RE-PLAT OF JACKSON FACTORY SUB, AS REC IN PB 1

PG 317 PRMCF, SD PT BEING THE PI OF THE E R/W LN OF 17TH AVE W & THE N R/W LN OF

10TH ST W; TH S 89 DEG 55 MIN 39 SEC E, ALG SD N R/W, A DIST OF 637.10 FT FOR A POB; TH CONT S 89 DEG 55 MIN 39 SEC E, ALG SD R/W LN, A DIST OF 166.00 FT; TH N 00 DEG 11 MIN 21 SEC W, 350.00 FT; TH N 89 DEG 55 MIN 39 SEC W, 166.00 FT; TH S 00 DEG 11 MIN 21 SEC E,

350.00 FT TO THE POB.

PROJECT LOCATION

MANATEE COUNTY

12TH ST W

COVER SHEET

06/17/26 -

ADDENDUM # 2

GENERAL CONSTRUCTION NOTES:

1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE LATEST STANDARDS OF CITY OF PALMETTO, FDEP, AND FDOT.

2. NO ENGINEERING PLANS SHALL BE USED FOR CONSTRUCTION UNLESS SPECIFICALLY MARKED "FOR

CONSTRUCTION". PRIOR TO COMMENCEMENT OF CONSTRUCTION THE CONTRACTOR SHALL VERIFY

THAT THE DIMENSIONS AND DETAILS SHOWN ON THE ENGINEERING PLANS ARE CORRECT AND ARE CONSTRUCTIBLE PRIOR TO ORDERING ANY MATERIALS. IN ADDITION, THE ACTUAL CONDITIONS AT THE JOB SITE SHOULD BE CONSIDERED IN THE VERIFICATION OF THE DIMENSIONS AND DETAILS. IF THERE

ARE ANY DISCREPANCIES WITH WHAT IS SHOWN ON THE CONSTRUCTION PLANS, THEY MUST

IMMEDIATELY REPORT THEM TO THE ENGINEER BEFORE DOING ANY WORK, OTHERWISE THE

CONTRACTOR ASSUMES FULL RESPONSIBILITY.

3. IN THE EVENT OF A DISAGREEMENT BETWEEN THE ENGINEERING PLANS, NOTES AND/OR DETAILS, THE CONTRACTOR SHALL SECURE WRITTEN INSTRUCTIONS FROM THE ENGINEER PRIOR TO PROCEEDING WITH ANY PART OF THE WORK AFFECTED BY OMISSIONS OR DISCREPANCIES. FAILING TO SECURE SUCH INSTRUCTION, THE CONTRACTOR WILL BE CONSIDERED TO HAVE PROCEEDED AT HIS OWN RISK AND EXPENSE. IN THE EVENT OF ANY DOUBT OR QUESTIONS ARISING WITH RESPECT TO THE TRUE MEANING OF THE CONSTRUCTION PLANS OR SPECIFICATIONS, THE DECISION OF THE ENGINEER SHALL BE FINAL

AND CONCLUSIVE.

4. ANY FIELD CHANGES OR DEVIATIONS FROM THESE PLANS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND IS SUBJECT TO THE APPROVAL OF BOTH THE OWNER AND CITY OF PALMETTO.

5. ALL TRENCH EXCAVATIONS IN EXCESS OF FIVE FEET IN DEPTH SHALL BE IN ACCORDANCE WITH THE

"TRENCH SAFETY ACT", EFFECTIVE DATE OCTOBER 1, 1990.

6. BEFORE ANY TREES ARE REMOVED BUT AFTER INITIAL CONSTRUCTION SURVEYING, THE CONTRACTOR

WILL CLEARLY FLAG ALL TREES TO BE PRESERVED AS APPROVED BY THE ENGINEER.

7. ALL DISTURBED AREAS WITHIN ROAD RIGHT OF WAY TO BE SODDED WITH BAHIA SOD. ALL DISTURBED

AREAS BEYOND ROAD RIGHT OF WAY TO BE RE-SODDED TO MATCH EXISTING CONDITIONS.

8. BENCHMARK DATUM MUST BE REFERRED TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88).

9. MAINTENANCE OF TRAFFIC SHALL BE IN ACCORDANCE WITH CURRENT FLORIDA D.O.T. STANDARDS AND

THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES.

10. LOCATIONS AND DIMENSIONS OF EXISTING RIGHTS-OF-WAY AND EASEMENTS ARE BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL VERIFY THE LIMITS OF THE RIGHTS-OF-WAY AND

EASEMENTS IN ORDER TO AVOID ENCROACHMENTS.

11. FIELD VERIFY SITE CONDITIONS AND THE SIZE AND LOCATION OF ALL EXISTING UTILITIES AND RELATED

CONSTRUCTION PRIOR TO COMMENCEMENT OF WORK.

12. THE CONTRACTOR SHALL ESTABLISH A BRASS DISK BENCHMARK ON THE CONTROL STRUCTURE WITH AN ELEVATION CERTIFIED IN WRITING TO THE COUNTY/CITY BY A REGISTERED PROFESSIONAL LAND

SURVEYOR.

13. ALL SIGNAGE AND STRIPING TO BE INSTALLED IN ACCORDING WITH MUTCD (LATEST EDITION)

STANDARDS AND SPECIFICATIONS.

LOT GRADING NOTES:

1. GRADES SHOWN ARE FINISHED GRADES.

2. INTERSECTING ROADS AND DRIVEWAYS TO BE GRADED AS DIRECTED BY THE ENGINEER, UNLESS

OTHERWISE NOTED.

3. LOT GRADING SHALL NOT IMPOSE ANY ADDITIONAL RUNOFF ONTO NOR IMPEDE RUNOFF FROM

ADJACENT PROPERTIES.

EROSION CONTROL & WATER QUALITY MANAGEMENT:

1. THE CONTRACTOR SHALL TAKE MEASURES DURING CONSTRUCTION TO PREVENT EROSION, TURBIDITY

AND SEDIMENTATION IN OFF-SITE SWALES, WETLANDS OR WATER BODIES.

2. ALL DISTURBED AREAS SHALL BE NEATLY GRADED, SEEDED AND MULCHED OR SODDED AS NOTED.

3. THE CONTRACTOR SHALL EXECUTE ALL MEASURES NECESSARY TO LIMIT THE TRANSPORT OF

SEDIMENTS OUTSIDE THE LIMITS OF THE PROJECT TO THE VOLUME AND AMOUNT THAT ARE EXISTING PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. THIS CONDITION WILL BE SATISFIED FOR THE TOTAL ANTICIPATED CONSTRUCTION PERIOD. PROVISION MUST BE MADE TO PRESERVE THE INTEGRITY OF GRADING PATTERNS, ETC. REQUIRED TO MEET THIS PROVISION THROUGHOUT THE LIFE OF THE

CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE HAY BALES, SILT BARRIERS, TEMPORARY

GRASSING, ETC. AS REQUIRED TO FULLY COMPLY WITH THE INTENT OF THIS SPECIFICATION.

4. NO EXCAVATED MATERIAL SHALL BE STOCKPILED IN SUCH A MANNER AS TO DIRECT RUNOFF DIRECTLY OFF THE PROJECT SITE OR INTO ANY ADJACENT WATER BODY OR STORMWATER COLLECTION FACILITY.

5. THE SURFACE AREA OF OPEN, RAW ERODIBLE SOIL EXPOSED BY CLEARING AND GRUBBING OPERATIONS OR EXCAVATION AND FILLING OPERATIONS SHALL NOT EXCEED 10 ACRES. THIS REQUIREMENT MAY BE WAIVED, FOR LARGE PROJECTS WITH A DUST CONTROL PLAN, WHICH DEMONSTRATES THAT OPENING OF ADDITIONAL AREAS WILL NOT SIGNIFICANTLY AFFECT OFF-SITE DEPOSIT OF SEDIMENTS. THIS

WAIVER WILL BE BY WRITTEN AUTHORIZATION FROM THE COUNTY ENGINEER.

6. INLETS AND CATCH BASINS SHALL BE PROTECTED FROM SEDIMENT LADEN STORMWATER RUNOFF UNTIL THE COMPLETION OF ALL CONSTRUCTION OPERATIONS THAT MAY CONTRIBUTE SEDIMENT TO THE INLET.

7. AREAS OPENED BY CONSTRUCTION OPERATIONS THAT ARE NOT ANTICIPATED TO BE DRESSED OR RECEIVE FINAL GRASSING TREATMENT WITH IN THIRTY DAYS SHALL BE SEEDED WITH A QUICK GROWING GRASS SPECIES WHICH WILL PROVIDE AN EARLY COVER, DURING THE SEASON IN WHICH IT IS PLANTED.

TEMPORARY SEEDING SHALL BE CONTROLLED SO AS TO NOT ALTER OR COMPETE WITH PERMANENT

GRASSING. THE RATE OF SEEDING SHALL BE 30 POUNDS PER ACRE.

8. THE SODDED OR SEEDED AND MULCHED AREA(S) SHALL BE ROLLED AND WATERED AS REQUIRED TO

ASSURE OPTIMUM GROWING CONDITIONS FOR THE ESTABLISHMENT OF A GOOD GRASS COVER.

9. IF AFTER 14 DAYS, THE TEMPORARY GRASSES AREAS HAVE NOT ATTAINED A MINIMUM OF 75% GOOD GRASS COVER, THE AREA WILL BE REWORKED AND ADDITIONAL SEED APPLIED TO ESTABLISH THE

DESIRED VEGETATION COVER.

10. ALL FEATURES OF THE PROJECT SHALL BE CONSTRUCTED TO PREVENT EROSION AND SEDIMENT AND SHALL BE MAINTAINED DURING THE LIFE OF THE CONSTRUCTION SO AS TO FUNCTION PROPERLY

WITHOUT THE TRANSPORT OF SEDIMENTS OUTSIDE THE LIMITS OF THE PROJECT.

11. ALL DISTURBED AREAS OUTSIDE THE EXCAVATION AND FILL LIMITS WILL BE RESTORED TO A CONDITION

EQUAL TO OR BETTER THAN THEIR CONDITION PRIOR TO CONSTRUCTION.

12. THE CONTRACTOR WILL BE RESPONSIBLE FOR MAINTENANCE OF ALL NEWLY PLANTED GRASSES OR VEGETATION AND RETENTION/DETENTION FACILITIES UNTIL THE WORK HAS BEEN ACCEPTED BY THE

COUNTY.

13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILITY OF EMBANKMENTS AND SHALL REPLACE ANY PORTION, WHICH IN THE OPINION OF THE ENGINEER, HAS BECOME DISPLACED DUE TO EROSION OR

DUE TO CARELESSNESS OR NEGLIGENCE ON THE PART OF THE CONTRACTOR.

14. THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL LAWS AND REGULATIONS CONTROLLING POLLUTION OF THE ENVIRONMENT. MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO CONTROL EROSION AND SEDIMENT RUNOFF FROM THE SITE DURING CONSTRUCTION. SUCH METHODS

SHALL BE IN ACCORDANCE WITH THE CURRENT FLORIDA DEPARTMENT OF TRANSPORTATION

STANDARDS.

15. ABSOLUTELY NO WORK WILL BE ALLOWED WITHIN ANY CONSERVATION AREA, BUFFER AREA, MITIGATION AREA OR DESIGNATED WETLAND AREA UNLESS SO SPECIFICALLY DESCRIBED BY THE PLANS AND GRANTED BY REASON OF PERMIT FROM THE GOVERNMENTAL ENTITY HAVING JURISDICTION OVER SAID

AREA.

16. PRIOR TO CLEARING AND GRUBBING, THE LIMITS OF WETLANDS, BUFFERS WETLANDS, BUFFERS AND

MITIGATION AREAS SHALL BE CLEARLY MARKED ALONG THE PROPOSED RIGHT OF WAY LINE TO

PROTECT THESE AREAS FROM ENCROACHMENT FROM CONSTRUCTION ACTIVITIES.

17. ALL FILL EMBANKMENT AND GRADED AREAS SHALL BE PROTECTED AGAINST EROSION BY METHODS STATED IN INDEX 570-001 F.D.O.T. STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION.

SIDE SLOPE MAY BE SEEDED AND MULCHED, PROVIDED THAT THE MULCH MATERIAL IS DISC HARROWED AND THE SIDE SLOPES ARE NEITHER GREATER THAN 3:1 NOR PART OF A DRAINAGE CONVEYANCE.

18. REFER TO POND DETAIL SHEETS FOR EROSION CONTROL MEASURES AT POND OUTFALLS.

19. EROSION CONTROL AT ALL INLET DRAINAGE STRUCTURES DURING CONSTRUCTION SHALL BE DONE IN

ACCORDANCE WITH FDOT INDEX.

20. LAND PREPARATION PROCESSES SHALL CONFORM TO "CHAPTER 6: STORMWATER, EROSION AND

SEDIMENT CONTROL BEST MANAGEMENT PRACTICES FOR DEVELOPING AREAS OF THE FLORIDA

DEVELOPMENT MANUAL: A GUIDE TO SOUND LAND AND WATER MANAGEMENT" (JUNE 1988) PREPARED

BY THE FLORIDA DEPARTMENT OF ENVIRONMENTAL REGULATION.

21. THE CONTRACTOR SHALL NOT LET DUST LEAVE THE SITE BY AIR. USE OF A WATER TRUCK TO CONTROL

DUST IS ADVISED.

PAVING AND DRAINAGE NOTES:

1. PIPE LENGTHS SHOWN REPRESENT SCALED DISTANCE BETWEEN TWO CENTERLINES OF DRAINAGE

STRUCTURE.

2. ALL MEDIANS AND ISLANDS TO BE FILLED WITH CLEAN SOIL.

3. ALL PAVEMENT RETURN RADI SHALL BE 25' AND MEASURED FROM THE INTERFACE TO THE CONCRETE

CURB AND PAVEMENT SURFACE UNLESS OTHERWISE NOTED.

4. ALL CONCRETE DRAINAGE STRUCTURES TO BE CONSTRUCTED PER D.O.T. ROADWAY AND TRAFFIC

DESIGN STANDARDS UNLESS OTHERWISE NOTED.

5. DITCH BOTTOM AND CONTROL STRUCTURE INLET GRATES SHALL BE SECURE WITH CHAIN AND EYE BOLT.

6. FIVE(5) FEET OF SOD IS REQUIRED AROUND ALL DITCH BOTTOM INLETS, MANHOLES, HEADWALLS AND

MITERED END SECTIONS.

7. CONTRACTOR SHALL PLACE BLUE REFLECTIVE MARKERS ON PAVEMENT IN FRONT OF FIRE HYDRANTS.

8. CONCRETE SIDEWALKS (AS SPECIFIED BY APPROPRIATE ROADWAY SECTION) ADJACENT TO ALL LOTS TO BE INSTALLED BY HOME BUILDER. SIDEWALKS ADJACENT TO PONDS, PARKS, AND OPEN SPACE, AS

SHOWN ON PLANS, ARE TO BE CONSTRUCTED WITH INFRASTRUCTURE.

9. THE CONTRACTOR SHALL INSTALL, AS PART OF THE INFRASTRUCTURE AND PRIOR TO CERTIFICATE OF COMPLETION, DROP CURBS AND HANDICAP RAMPS AT ALL INTERSECTIONS OF SIDEWALK WITH THE

PROPOSED PAVEMENT TO MEET CITY OF PALMETTO A.D.A. SPECIFICATIONS

10. TOP ELEVATION MANHOLES IN GRASSED AREAS SHALL BE AT A MINIMUM 4 INCHES ABOVE FINISH GRADE.

11. MINIMUM LONGITUDINAL SLOPE OF CURB SHALL BE 0.24%.

12. IT SHALL BE CONTRACTOR'S RESPONSIBILITY TO PROVIDE DOCUMENTATION, FOR THE ADS HP STORM PIPE, FROM THE PIPE MANUFACTURER CONFIRMING SUFFICIENT COVER HAS BEEN PROVIDED TO

PREVENT FLOTATION. IN THE EVENT THAT ADEQUATE COVER IS NOT PROVIDED, IT IS THE

CONTRACTOR'S RESPONSIBILITY TO OBTAIN DESIGN AND CONSTRUCTION SPECIFICATIONS FROM THE MANUFACTURER, FOR THE ADS N-12 HP PIPE ANCHORING SYSTEM. IF ADS HP STORM PIPE IS USED THEN MITERED END SECTIONS (MES) MAY BE SUBSTITUTED FOR FLARED END SECTIONS (FES) AT PIPE RUN

TERMINATIONS.

AS-BUILT NOTES:

1. THE CONTRACTOR SHALL SUBMIT A CERTIFIED SET OF RECORD DRAWINGS TO THE ENGINEER. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING INFORMATION ON THE APPROVED PLANS

CURRENTLY WITH CONSTRUCTION PROGRESS. RECORD DRAWINGS SUBMITTED TO THE ENGINEER AS

PART OF THE PROJECT ACCEPTANCE SHALL COMPLY WITH CITY OF PALMETTO SUBDIVISION

REQUIREMENTS AND THE FOLLOWING REQUIREMENTS:

1.1. DRAWINGS SHALL BE LEGIBLY MARKED TO RECORD ACTUAL CONSTRUCTION.

1.2. DRAWINGS SHALL SHOW LOCATION OF ALL UNDERGROUND AND ABOVE GROUND WATER,

WASTEWATER AND RECLAIMED WATER PIPING AND RELATED APPURTENANCES, BASED UPON

RECORD SURVEY INFORMATION. ALL CHANGES TO PIPING LOCATION INCLUDING HORIZONTAL AND

VERTICAL LOCATIONS OF UTILITIES AND APPURTENANCES SHALL BE CLEARLY SHOWN AND

REFERENCED TO PERMANENT SURFACE IMPROVEMENTS AND ROAD RIGHTS-OF-WAY.

1.3. DRAWINGS SHALL ALSO IDENTIFY ACTUAL INSTALLED PIPE, VALVES, FITTINGS, HYDRANTS AND

OTHER ASSETS. THESE ASSETS SHALL BE ATTRIBUTED WITH MATERIALS, CLASS, PRESSURE

RATING, SPECIFICATIONS, ETC.

1.4. DRAWINGS SHALL CLEARLY SHOW ALL FIELD CHANGES OF DIMENSION AND DETAIL INCLUDING

CHANGES MADE BY FIELD ORDER OR BY CHANGE ORDER.

1.5. DRAWINGS SHALL CLEARLY SHOW ALL DETAILS NOT ON ORIGINAL CONTRACT DRAWINGS BUT

CONSTRUCTED IN THE FIELD. ALL EQUIPMENT AND PIPING RELOCATION SHALL BE CLEARLY

SHOWN.

1.6. DRAWINGS SHALL CLEARLY SHOW THE ACTUAL HORIZONTAL LOCATIONS, DISTANCES, AND

VERTICAL ELEVATIONS OF THE UTILITY ASSETS. STATE PLANE COORDINATES SHALL BE UTILIZED

FOR HORIZONTAL LOCATIONS.

1.7. DIMENSIONS BETWEEN ALL MANHOLES, SLOPE OF GRAVITY MAINS, INVERT AND TOP ELEVATIONS

SHALL BE SHOWN.

1.8. CONTRACTOR SHALL PROVIDE AS-BUILT SURVEY FOR POND GRADING. AS-BUILT POND CONTOURS SHALL BE PROVIDED AT TOP OF BANK, POND BOTTOM, AND ALL GRADE BREAKS AND ELEVATIONS SPECIFIED ON THE PLANS. CONTRACTOR SHALL BE RESPONSIBLE FOR RE-GRADING POND SLOPES THAT ARE STEEPER THAN 5:1 (HORIZONTAL:VERTICAL) TO A DEPTH OF 2 FEET BELOW THE SLWT.

1.9. EACH SHEET OF THE PLANS SHALL BE SIGNED, SEALED AND DATED BY REGISTERED SURVEYOR

WITH A NOTE READING, "THESE AS-BUILT DRAWINGS ACCURATELY DEPICT THE ACTUAL

IMPROVEMENTS AS CONSTRUCTED."

1.10. DRAWINGS SHALL INCLUDE THE AS-BUILT COORDINATE ASSET TABLE, PIPE DEFLECTION, AND

GRAVITY MAIN TABLE.

2. CONTRACTOR TO PLACE GRADE STAKES AT CENTER OF FRONT AND REAR LIMITS OF EACH BUILDING PAD

FOR OWNER/ENGINEER INSPECTION AND APPROVAL.

3. CERTIFIED AS-BUILT DRAWINGS SHALL BE PROVIDED TO THE ENGINEER PRIOR TO BACTERIOLOGICAL TESTING. FAILURE TO PROVIDE ACCURATE DRAWINGS MAY RESULT IN EXPIRED TEST RESULTS AND

REQUIRE ADDITIONAL TESTING AT THE CONTRACTOR'S EXPENSE.

4. THE CONTRACTOR SHALL SUBMIT TWO (2) CERTIFIED COPIES AND EXCEL FILES OF THE COMPLETED UTILITY ASSET TABLES USING THE CITY OF PALMETTO STANDARD ASSET TABLES TEMPLATE AVAILABLE ON THEIR WEBSITE. COMPLETE ASSET TABLE REQUIRED PRIOR TO ANY CERTIFICATION OF RESPECTIVE

SYSTEM. COORDINATE DATA SHALL BE PROVIDED IN STATE PLANE COORDINATES.

AS-BUILT - RECORD DRAWINGS NOTES:

GENERAL:

CONTRACTOR SHALL PROVIDE THE ENGINEER OF RECORD WITH AN ACCURATE "AS-BUILT" SURVEY DEPICTING THE IMPROVEMENTS AS CONSTRUCTED AND NOTING ANY CHANGES. AS-BUILT SURVEY SHALL BE SIGNED AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL LAND SURVEYOR AND MAPPER. A PAPER COPY SHALL BE SUBMITTED ALONG WITH AN ELECTRONIC FILE IN AUTOCAD FORMAT. "AS-BUILT" SURVEY

SHALL MEET THE STANDARDS AND SPECIFICATIONS OF CITY OF PALMETTO, AND SWFWMD.

UTILITIES:

AT A MINIMUM, UTILITY "AS-BUILT" INFORMATION WILL REQUIRE THE LOCATION OF ALL FITTINGS, VALVES, HYDRANTS, ETC. AND THE CHANGE OF DIRECTION AND ELEVATION OF ALL WATER MAINS, INCLUDING VERTICAL AND HORIZONTAL SEPARATION OF ALL CROSSINGS AND CONFLICTS. CONTRACTOR SHALL MAKE PROVISIONS DURING CONSTRUCTION TO FACILITATE THE COLLECTION OF "AS-BUILT" DATA, INCLUDING, IF NECESSARY, INSTALLING PVC SLEEVES OVER WATER MAIN FITTINGS, COLLECTING SURVEY DATA AS IT IS

INSTALLED, OR TAKING FIELD MEASUREMENTS OF CONFLICTS PRIOR TO PLACING COVER.

IRRIGATION NOTES

1. ALL IRRIGATION PIPING CROSSING UNDER DRIVES AND ROADS SHALL BE IN PVC SLEEVES TWICE THE

DIAMETER OF THE PIPE, 4" O.D. MAX.

2. IRRIGATION EQUIPMENT (SPRINKLER HEADS, VALVES, CONTROLLER, ETC.) TO BE AS MANUFACTURED BY

RAINBIRD SPRINKLER MFG. CO. OR APPROVED EQUIVALENT.

3. ALL HEADS AND VALVES SHALL BE LOCATED IN ADJACENT PLANTING AREA AS DETAILED.

4. HEAD ON SHRUB RISERS SHALL NOT EXTEND MORE THAN 6" ABOVE ADJACENT PLANT MATERIAL.

5. ALL EXPOSED PVC WILL BE PAINTED BLACK.

6. CONTRACTOR SHALL USE CARE AND MINIMIZE ROOT DAMAGE WHEN INSTALLING IRRIGATION

COMPONENTS NEAR EXISTING TREES. WHEN ANY ROOTS OF EXISTING TREES ARE ENCOUNTERED

DURING INSTALLATION OF UTILITIES, THE LINES SHALL BE ADJUSTED BY THE ARCHITECT. IF ROOTS MUST BE CUT, THEY SHALL BE CUT OFF EVENLY WITH CLEAN SHARP PRUNING TOOLS. THE INSTALLER

SHALL MINIMIZE THE DAMAGE TO EXISTING TREE ROOT SYSTEMS.

7. IRRIGATION DIAGRAM SHOWN FOR SPRINKLER HEAD SPACING IS TYPICAL. IRRIGATION CONTRACTOR SHOULD REFER TO IRRIGATION DESIGN PLANS FOR HEAD LAYOUT AND SPACING. IF NO IRRIGATION

DESIGN HAS BEEN PREPARED, THE CONTRACTOR SHALL SIZE HEADS, ZONES AND LATERALS AS

APPROPRIATE TO PROVIDE FULL COVERAGE OF ALL LANDSCAPED AREAS.

8. SYSTEM SHALL PROVIDE 100% GREEN SPACE COVERAGE.

SIDEWALKS:

1. ALL OTHER SIDEWALKS TO BE CONSTRUCTED WITH SITE IMPROVEMENTS.

2. HANDICAP (HC) RAMPS MUST BE CONSTRUCTED AT THE STREET INTERSECTION(S) AND DRIVEWAY CONNECTION(S) TO COMPLY WITH THE AMERICAN WITH DISABILITY ACT (ADA) AND WILL MEET FDOT

DESIGN STANDARDS.

SANITARY SEWER NOTES

1. ALL MATERIALS AND CONSTRUCTION SHALL BE IN COMPLIANCE WITH CITY OF PALMETTO MANUAL OF

STANDARD SPECIFICATIONS FOR WASTEWATER AND WATERMAIN CONSTRUCTION.

2. ALL MANHOLES SHALL HAVE A MINIMUM DIAMETER OF 48 INCHES AND A MINIMUM ACCESS DIAMETER OF

22 INCHES.

3. PIPE LENGTHS SHOWN REPRESENT SCALED DISTANCES BETWEEN MANHOLE CENTERLINE.

4. ALL SANITARY SERVICE LATERALS SHALL BE 6 INCH DIAMETER PVC. LATERALS SHALL END WITH A CLEAN

OUT AT RIGHT-OF-WAY LINE.

5. INVERTS OF SANITARY SERVICE LATERALS AT THEIR CONNECTION TO SANITARY MANHOLES SHALL BE

NO MORE THAN ONE (1) FOOT ABOVE THE MANHOLE INVERT.

6. PRIOR TO PAVING, CONTRACTOR SHALL VERIFY THE AS-BUILT SANITARY SEWER PIPE SLOPES. MINIMUM AS SHALL BE IN ACCORDANCE WITH FDEP MINIMUM CRITERIA BUILT FOR 8" PVC SEWER LINE SLOPE WILL BE 0.28%, FOR 12" PVC WILL BE 0.17%, AND FOR 15" PVC WILL BE 0.12%. ANY LINE NOT MEETING MINIMUM

SLOPE WILL BE RELAYED BY CONTRACTOR TO MEET THE MINIMUM SLOPE REQUIREMENT AT NO

ADDITIONAL COST.

7. MARK LATERALS WITH 6' HIGH PIECE OF 2" X 4" PLANK PAINTED GREEN W/ LOT NUMBER CLEARLY

MARKED AND A 'S' IMPRESSED IN THE CURB.

8. MINIMUM SEPARATION BETWEEN POTABLE WATER LINES AND SANITARY HAZARDS (SANITARY SEWER, FORCE MAIN, STORM SEWER, REUSE WATER) SHALL BE MAINTAINED. A HORIZONTAL CLEARANCE OF TEN

(10) FEET IN PARALLEL INSTALLATION AND 12 INCHES VERTICALLY AT CROSSINGS. SHOULD A VERTICAL SEPARATION OF LESS THAN THAT STIPULATED BE REQUIRED, THE WATER LINE SHALL BE CONSTRUCTED OF 20 FEET OF PRESSURE TIGHT JOINT DUCTILE IRON PIPE. IF THE REQUIRED 10 FT. HORIZONTAL CLEARANCE CANNOT BE MAINTAINED, THE SEWER MAIN SHALL BE PLACED IN A D.I.P. SLEEVE OR

ENCASED IN CONCRETE IN ACCORDANCE WITH FDEP SPECIFICATIONS.

9. PVC GRAVITY SEWER PIPE SHALL MEET ASTM D3034, SDR35.

10. ALL SANITARY SEWER PIPE SHALL BE COLORED GREEN.

11. FIBERGLASS LINE ALL MANHOLES WHICH RECEIVE DISCHARGE FROM A FORCE MAIN AND NEXT

DOWNSTREAM MANHOLE.

12. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SERVICES AT EACH LOT. SERVICES SHALL HAVE 3' MIN

AND 4' MAX COVER AT LOT CLEAN OUT.

POTABLE WATER NOTES (PRIVATE):

1. ALL CONSTRUCTION AND MATERIALS SHALL BE IN COMPLIANCE WITH AWWA STANDARDS AND IN

ACCORDANCE WITH CITY OF PALMETTO REGULATIONS.

2. PIPE LENGTHS SHOWN REPRESENT SCALED DISTANCES BETWEEN FITTINGS OF BRANCHES AND MAINS.

3. DEFLECTIONS AT PIPE JOINTS SHALL NOT EXCEED THOSE RECOMMENDED BY THE PIPE MANUFACTURER.

4. ALL GATE VALVES SHALL BE EQUIPPED WITH AN ADJUSTABLE CAST IRON VALVE BOX WITH COVER, WITH

THREADED CAST BRONZE EXTENSION WHERE NEEDED.

5. ALL PUBLIC WATER SYSTEM COMPONENTS, EXCLUDING FIRE HYDRANTS, THAT WILL BE INSTALLED UNDER THIS PROJECT AND THAT WILL COME INTO CONTACT WITH DRINKING WATER WILL CONFORM TO

NSF INTERNATIONAL STANDARD 61 AND WILL BE MARKED WITH THE NSF SEAL OF APPROVAL.

6. ALL PIPE AND PIPE FITTINGS INSTALLED UNDER THIS PROJECT SHALL BE COLOR CODED IN ACCORDANCE WITH THE SUB PARAGRAPH 62-555.320(21)(B)3, F.A.C. USING BLUE AS A PREDOMINANT COLOR. ALL DUCTILE IRON WATER MAINS SHALL BE MARKED WITH A CONTINUOUS STRIPE LOCATED WITHIN THE TOP 90 DEGREES OF THE PIPE. SAID STRIPE SHALL BE A MINIMUM 2 INCHES IN WITH AND SHALL BE BLUE IN COLOR. BACKFILL SHALL NOT BE PLACED FOR 30 MINUTES FOLLOWING PAINT APPLICATION. FOR PIPE WITH AN INTERNAL DIAMETER OF 24" OR GREATER, TAPE OR PAINT SHALL BE APPLIED IN CONTINUOUS LINES ALONG EACH SIDE OF THE PIPE AS WELL AS ALONG THE TOP OF THE

PIPE.

7. ALL NON-METALLIC WATERMAINS SHALL BE INSTALLED WITH A CONTINUOUS, INSULATED 10 GAUGE COPPER WIRE INSTALLED DIRECTLY ON TOP OF THE PIPE FOR LOCATION PURPOSES. SEE STANDARD DRAWINGS. IN ADDITION, ALL PVC WATERMAINS SHALL BE A SOLID BLUE COLOR. ALL LETTERING SHALL APPEAR LEGIBLY ON PIPE AND SHALL RUN THE ENTIRE LENGTH OF THE PIPE. LETTERING SHALL READ AS

IS ACCEPTABLE FOR THE INTENDED USE.

8. WATERMAIN CONNECTION SHALL BE MADE UNDER THE SUPERVISION OF CITY OF PALMETTO

PERSONNEL. ALL VALVES SHALL BE OPERATED BY CITY OF PALMETTO PERSONNEL ONLY. WATERMAINS

ARE TO BE DISINFECTED PER ANSI/AAWA C651-92 REGULATIONS.

9. VERTICAL SEPARATION BETWEEN UNDERGROUND POTABLE WATERMAINS AND SANITARY OR STORM

SEWERS, WASTEWATER OR STORMWATER FORCE MAINS, AND RECLAIMED WATER PIPELINES:

9.1. NEW OR RELOCATED, UNDERGROUND WATERMAINS CROSSING ANY EXISTING OR PROPOSED

GRAVITY- OR VACUUM-TYPE SANITARY SEWER OR STORM SEWER SHALL BE LAID SO THE OUTSIDE OF THE WATERMAIN IS AT LEAST SIX INCHES, AND PREFERABLY 12 INCHES ABOVE OR BELOW THE OUTSIDE OF THE OTHER PIPELINE. HOWEVER, IT IS PREFERABLE TO LAY THE WATERMAIN ABOVE

THE OTHER PIPELINE.

9.2. NEW OR RELOCATED, UNDERGROUND WATERMAINS CROSSING ANY EXISTING OR PROPOSED

PRESSURE-TYPE SANITARY SEWER, WASTEWATER OR STORMWATER FORCE MAIN, OR PIPELINE

CONVEYING RECLAIMED WATER SHALL BE LAID SO THE OUTSIDE OF THE WATERMAIN IS AT LEAST 12 INCHES ABOVE OR BELOW THE OUTSIDE OF THE OTHER PIPELINE. HOWEVER, IT IS PREFERABLE

TO LAY THE WATERMAIN ABOVE THE OTHER PIPELINE.

9.3. AT THE UTILITY CROSSINGS DESCRIBED IN PARAGRAPHS (A) AND (B) ABOVE, ONE FULL LENGTH OF

WATERMAIN PIPE SHALL BE CENTERED ABOVE OR BELOW THE OTHER PIPELINE SO THE

WATERMAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE OTHER PIPELINE. ALTERNATIVELY, AT SUCH CROSSING, THE PIPES SHALL BE ARRANGED SO THAT ALL WATERMAIN JOINTS ARE AT LEAST

THREE FEET FROM ALL JOINTS IN VACUUM-TYPE SANITARY SEWERS, STORM SEWERS,

STORMWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER REGULATED UNDER

PART III OF CHAPTER 62-610, F.A.C., AND AT LEAST SIX FEET FROM ALL JOINTS IN GRAVITY-OR

PRESSURE-TYPE SANITARY SEWERS, WASTEWATER FORCE MAINS, OR PIPELINES CONVEYING

RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.

10. HORIZONTAL SEPARATION BETWEEN UNDERGROUND WATERMAINS AND SANITARY OR STORM SEWERS, WASTEWATER OR STORMWATER FORCE MAINS, RECLAIMED WATER PIPELINES, AND ON-SITE SEWAGE

TREATMENT AND DISPOSAL SYSTEMS:

10.1. NEW OR RELOCATED, UNDERGROUND WATERMAINS SHALL BE LAID TO PROVIDE A HORIZONTAL

DISTANCE OF AT LEAST THREE FEET BETWEEN THE OUTSIDE OF THE WATERMAIN AND THE

OUTSIDE OF ANY EXISTING OR PROPOSED STORM SEWER, STORWATER FORCE MAIN, OR PIPELINE

CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.

10.2. NEW OR RELOCATED, UNDERGROUND WATERMAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST THREE FEET, AND PREFERABLY 10 FEET, BETWEEN THE OUTSIDE OF THE WATERMAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED VACUUM-TYPE SANITARY SEWER.

10.3. NEW OR RELOCATED, UNDERGROUND WATERMAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST SIX FEET, AND PREFERABLY 10 FEET, BETWEEN THE OUTSIDE OF THE

WATERMAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED GRAVITY-OR PRESSURE-TYPE

SANITARY SEWER, WASTEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER NOT

REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C. THE MINIMUM HORIZONTAL SEPARATION

DISTANCE BETWEEN WATERMAINS AND GRAVITY-TYPE SANITARY SEWERS SHALL BE REDUCED TO

THREE FEET WHERE THE BOTTOM OF THE WATERMAINS IS LAID AT LEAST SIX INCHES ABOVE THE

TOP OF THE SEWER.

10.4. NEW OR RELOCATED, UNDERGROUND WATERMAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST TEN FEET BETWEEN THE OUTSIDE OF THE WATERMAIN AND ALL PARTS OF ANY EXISTING OR PROPOSED "ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEM" AS DEFINED

IN SECTION 381.0065(2), F.S., AND RULE 64E-6.002, F.A.C.

11. A MINIMUM OF 3 FEET OF COVER SHALL BE MAINTAINED OVER WATERMAINS, UNLESS OTHERWISE

NOTED.

12. ALL PIPE AND PIPE FITTINGS INSTALLED UNDER THIS PROJECT SHALL CONTAIN NO MORE THAN 8.0% LEAD, AND ANY SOLDER OR FLUX USED IN THIS PROJECT SHALL CONTAIN NO MORE THAN 0.2% LEAD.

13. NEW OR ALTERED DEAD-END WATERMAINS INCLUDED IN THIS PROJECT SHALL BE PROVIDED WITH A FIRE

OR FLUSHING HYDRANT OF BLOW-OFF FOR FLUSHING PURPOSES.

14. NEW OR ALTERED FIRE HYDRANTS LEADS SHALL HAVE A MINIMUM INSIDE DIAMETER OF 6" AND SHALL

INCLUDE AN AUXILIARY VALVE.

15. IF AGGRESSIVE SOIL CONDITIONS ARE FOUND DURING CONSTRUCTION, WATERMAINS SHALL BE PROTECTED THROUGH THE USE OF CORROSION RESISTANT MATERIALS, THROUGH ENCASEMENT OF

THE WATERMAINS IN POLYETHYLENE, OR THROUGH PROVISION OF CATHODIC PROTECTION.

16. A CONTINUOUS AND UNIFORM BEDDING WILL BE PROVIDED IN TRENCHES FOR UNDERGROUND PIPE

INSTALLED UNDER THIS PROJECT; BACKFILL MATERIAL WILL BE TAMPED IN LAYERS AROUND

UNDERGROUND PIPE INSTALLED UNDER THIS PROJECT AND TO A SUFFICIENT HEIGHT ABOVE THE PIPE TO ADEQUATELY SUPPORT AND PROTECT THE PIPE; AND UNSUITABLY SIZED STONES (AS DESCRIBED IN

APPLICABLE AWWA STANDARDS OR MANUFACTURERS' RECOMMENDED INSTALLATION PROCEDURES)

FOUND IN TRENCHES WILL BE REMOVED FOR A DEPTH OF AT LEAST SIX INCHES BELOW THE BOTTOM OF

UNDERGROUND PIPE INSTALLED UNDER THIS PROJECT.

WATER - MATERIALS (PRIVATE):

1. PVC PIPE:

1.1. PVC WATER DISTRIBUTION MAINS SHALL BE MANUFACTURED IN ACCORDANCE WITH AWWA

STANDARD C900 OR C909, LATEST EDITION.

1.2. PIPE SHALL HAVE A MINIMUM PRESSURE RATING OF 150 PSI AND HAVE A MAXIMUM DIMENSION

RATIO OF 18.

1.3. PIPE SHALL BE BLUE IN COLOR.

1.4. PVC PIPE SHALL HAVE INTEGRAL BELL PUSH ON TYPE JOINTS CONFORMING TO ASTM D3139.

2. DUCTILE IRON PIPE:

2.1. DUCTILE IRON PIPE SHALL CONFORM TO ANSI/AWWA A21.51/C151.

2.2. PIPE SHALL BE PRESSURE CLASS OF 350 FOR PIPE 4 TO 12 INCHES IN DIAMETER. PIPES 16 TO 24 INCHES IN DIAMETER SHALL BE PRESSURE CLASS 250. PIPES 30 TO 64 INCHES IN DIAMETER SHALL

BE PRESSURE CLASS 200.

2.3. PIPE SHALL BE COLOR CODED BLUE WITH TAPE.

2.4. THE TAPE (MIN 2”) SHALL BE PERMANENTLY AFFIXED TO THE TOP AND EACH SIDE OF THE PIPE (THREE LOCATIONS PARALLEL TO THE AXIS OF THE PIPE). FOR PIPES LESS THAN 24 INCHES IN

DIAMETER, A SINGLE TAPE MAY BE USED ALONG THE TOP OF THE PIPE.

2.5. JOINTS FOR DUCTILE IRON PIPE SHALL BE PUSH-ON OR MECHANICAL JOINTS CONFORMING TO ANSI/AWWA A21.11/C111, RESTRAINED OR FLANGED JOINTS SHALL BE PROVIDED WHERE CALLED FOR IN THE PLANS. FLANGED POINTS SHALL CONFORM TO ANSI STANDARD B 16.1-125 POUNDS.

3. HDPE PIPE:

3.1. HDPE PIPE SHALL BE IN ACCORDANCE WITH AWWA C906 AND SHALL HAVE AN OUTSIDE DIAMETER

EQUAL TO DUCTILE IRON PIPE FOR THE SAME SIZE.

3.2. PIPE SHALL HAVE A MINIMUM DIMENSION RATIO OF 11 FOR USE WITH DUCTILE IRON PIPE FITTINGS

AND HAVE A WORKING PRESSURE OF 150 PSI.

3.3. HDPE JOINTS SHALL CONFORM TO AWWA C906.

4. POLYETHYLENE ENCASEMENT SHALL BE IN ACCORDANCE WITH ANSI/AWWA A21.51/C105, WRAPPING

COLORS TO BE BLUE.

5. GATE VALVES SHALL BE RESILIENT SEAT GATE VALVES, MANUFACTURED TO MEET OR EXCEED THE

REQUIREMENTS OF AWWA C509 / C515, LATEST REVISION, AND IN ACCORDANCE WITH THESE

SPECIFICATIONS. VALVES SHALL HAVE AN UNOBSTRUCTED WATERWAY EQUAL TO OR GREATER THAN THE FULL NOMINAL DIAMETER OF THE VALVE. VALVES SHALL HAVE A MINIMUM PRESSURE RATING OF 250

PSI.

6. ALL VALVES SHALL OPEN LEFT OR COUNTER CLOCKWISE.

WATER - TESTING (PRIVATE):

1. HYDROSTATIC TESTS SHALL CONSIST OF PRESSURE TEST AND LEAKAGE TEST. HYDROSTATIC TESTS SHALL BE CONDUCTED ON ALL NEWLY LAID PRESSURE PIPES, JOINTS AND VALVES INCLUDING ALL

SERVICE LINES TO THE CURB STOPS.

2. ALL PIPE SECTIONS TO BE PRESSURE TESTED SHALL BE SUBJECTED TO A MINIMUM HYDROSTATIC PRESSURE OF 150 PSI. THE DURATION OF EACH PRESSURE TEST SHALL BE FOR A PERIOD OF TWO

HOURS. PROVISIONS OF AWWA C600, AND C651 WHERE APPLICABLE, SHALL APPLY.

3. AFTER COMPLETION OF THE PRESSURE TEST, A LEAKAGE TEST SHALL BE CONDUCTED TO DETERMINE THE QUANTITY OF WATER LOST BY LEAKAGE UNDER THE SPECIFIED TEST PRESSURE. APPLICABLE

PROVISIONS OF AWWA C600 SHALL APPLY.

4. NEWLY INSTALLED MAINS SHALL BE FILLED, FLUSHED WITH A MINIMUM VELOCITY OF 2.5 FEET PER

SECOND AND DISINFECTED IN ACCORDANCE WITH THE ANSI/AWWA C651.

WATER - MATERIALS (PRIVATE):

1. PVC PIPE:

1.1. PVC WATER DISTRIBUTION MAINS SHALL BE MANUFACTURED IN ACCORDANCE WITH AWWA

STANDARD C900 OR C909, LATEST EDITION.

1.2. PIPE SHALL HAVE A MINIMUM PRESSURE RATING OF 150 PSI AND HAVE A MAXIMUM DIMENSION

RATIO OF 18.

1.3. PIPE SHALL BE BLUE IN COLOR.

1.4. PVC PIPE SHALL HAVE INTEGRAL BELL PUSH ON TYPE JOINTS CONFORMING TO ASTM D3139.

2. DUCTILE IRON PIPE:

2.1. DUCTILE IRON PIPE SHALL CONFORM TO ANSI/AWWA A21.51/C151.

2.2. PIPE SHALL BE PRESSURE CLASS OF 350 FOR PIPE 4 TO 12 INCHES IN DIAMETER. PIPES 16 TO 24

INCHES IN DIAMETER SHALL BE PRESSURE CLASS 250. PIPES 30 TO 64 INCHES IN DIAMETER SHALL

BE PRESSURE CLASS 200.

2.3. PIPE SHALL BE COLOR CODED BLUE WITH TAPE.

2.4. THE TAPE (MIN 2”) SHALL BE PERMANENTLY AFFIXED TO THE TOP AND EACH SIDE OF THE PIPE

(THREE LOCATIONS PARALLEL TO THE AXIS OF THE PIPE). FOR PIPES LESS THAN 24 INCHES IN

DIAMETER, A SINGLE TAPE MAY BE USED ALONG THE TOP OF THE PIPE.

2.5. JOINTS FOR DUCTILE IRON PIPE SHALL BE PUSH-ON OR MECHANICAL JOINTS CONFORMING TO ANSI/AWWA A21.11/C111, RESTRAINED OR FLANGED JOINTS SHALL BE PROVIDED WHERE CALLED FOR IN THE PLANS. FLANGED POINTS SHALL CONFORM TO ANSI STANDARD B 16.1-125 POUNDS.

3. HDPE PIPE:

3.1. HDPE PIPE SHALL BE IN ACCORDANCE WITH AWWA C906 AND SHALL HAVE AN OUTSIDE DIAMETER

EQUAL TO DUCTILE IRON PIPE FOR THE SAME SIZE.

3.2. PIPE SHALL HAVE A MINIMUM DIMENSION RATIO OF 11 FOR USE WITH DUCTILE IRON PIPE FITTINGS

AND HAVE A WORKING PRESSURE OF 150 PSI.

3.3. HDPE JOINTS SHALL CONFORM TO AWWA C906.

4. POLYETHYLENE ENCASEMENT SHALL BE IN ACCORDANCE WITH ANSI/AWWA A21.51/C105, WRAPPING

COLORS TO BE BLUE.

5. GATE VALVES SHALL BE RESILIENT SEAT GATE VALVES, MANUFACTURED TO MEET OR EXCEED THE

REQUIREMENTS OF AWWA C509 / C515, LATEST REVISION, AND IN ACCORDANCE WITH THESE

SPECIFICATIONS. VALVES SHALL HAVE AN UNOBSTRUCTED WATERWAY EQUAL TO OR GREATER THAN THE FULL NOMINAL DIAMETER OF THE VALVE. VALVES SHALL HAVE A MINIMUM PRESSURE RATING OF 250

PSI.

6. ALL VALVES SHALL OPEN LEFT OR COUNTER CLOCKWISE.

WATER - TESTING:

1. HYDROSTATIC TESTS SHALL CONSIST OF PRESSURE TEST AND LEAKAGE TEST. HYDROSTATIC TESTS SHALL BE CONDUCTED ON ALL NEWLY LAID PRESSURE PIPES, JOINTS AND VALVES INCLUDING ALL

SERVICE LINES TO THE CURB STOPS.

2. ALL PIPE SECTIONS TO BE PRESSURE TESTED SHALL BE SUBJECTED TO A MINIMUM HYDROSTATIC PRESSURE OF 150 PSI. THE DURATION OF EACH PRESSURE TEST SHALL BE FOR A PERIOD OF TWO

HOURS. PROVISIONS OF AWWA C600, AND C651 WHERE APPLICABLE, SHALL APPLY.

3. AFTER COMPLETION OF THE PRESSURE TEST, A LEAKAGE TEST SHALL BE CONDUCTED TO DETERMINE THE QUANTITY OF WATER LOST BY LEAKAGE UNDER THE SPECIFIED TEST PRESSURE. APPLICABLE

PROVISIONS OF AWWA C600 SHALL APPLY.

4. NEWLY INSTALLED MAINS SHALL BE FILLED, FLUSHED WITH A MINIMUM VELOCITY OF 2.5 FEET PER

SECOND AND DISINFECTED IN ACCORDANCE WITH THE ANSI/AWWA C651.

SIGNING AND STRIPING NOTES:

1. ALL PAVEMENTS MARKINGS MUST COMPLY WITH FDOT INDEX 711-001.

2. ALL PAVEMENT MARKINGS IN THE ROW WILL BE THERMOPLASTIC, AND THEY WILL FOLLOW THE FDOT

STANDARDS PLANS 711-001.

3. TRAFFIC SIGNS NOT TO BE INSTALLED IN CONCRETE.

4. STREET SIGNS POSTS TO BE SQUARE GALVANIZED STEEL AND HOLES SHALL BE CORED. 2 INCH SQUARE

GALVANIZED POLES SHALL BE PRE-SCORED ALSO CALLED QUICK PUNCH.

5. ALL TRAFFIC CONTROL SIGNS WITHIN THE RIGHT-OF-WAY SHALL BE MANUFACTURED USING DIAMOND GRADE REFLECTIVE SHEETING. ALL SIGNS SHALL BE CONSTRUCTED IN ACCORDANCE WITH MUTCD AND

CITY OF PALMETTO CRITERIA FOR SIGN SIZE AND SHAPE AND LETTERING DIMENSIONS.

2/ 5/

:1

6:

P M

Au to de sk

D oc s:

//1

0.

N

G A

D ad e C ity /1

0.

D

M A

C

FM

O D

AD

E

C

IT

Y

ES

P R

EN

O

VA

TI

O N

S.

rv t

C2.1

GENERAL CONSTRUCTION

NOTES

SHEET NO.:

PROJECT NO.:

DATE:

SHEET TITLE:

DRAWN BY:

REVISIONS:

RG

1910.09

JULY 10, 2025

PA

LM

ET

TO

E

SP

R

EN

O

VA

TI

O

N

4T

H A

VE

W

, P

AL

M

ET

TO

, F

L

N

AT

IO

N

AL

G

U

AR

D A

R M

O R

Y

D M

A C

FM

O

0% C

O N

ST

R

U C

TI

O

N D

O C

U M

EN

T

SU

BM

IT

TA

L

06/17/26 -

ADDENDUM # 2

FLAGPOLE

PLAQUE MYRTLE 4 4

3 3

10.43

GI

8.21

INV S 15 RCP

MYRTLE 4 4

3 3

MYRTLE 4 4

3 3

MYRTLE 4 4

3 3

MYRTLE 5 4

3 4

10.35

GI

8.12

N INV 15 RCP

8.08

S INV 15 RCP

GA

PED

10.54

GI

7.96

N INV 15 RCP

8.06

S INV 15 RCP

36 30

MHS

11.80

MHS

11.65

16 16 15 15PED

GA

10.17

EBX

PED

MHS

10.01

10.38

BFP

10.29

BFP

10.34

ELEC OUTLET

22 18

1415 9

15 15

9.75

GI

6.70

INV E 15 RCP

6.72

INV NW 15 RCP

6.16

MES INV 15 RCP

10.24

SKIMMER

10.28

SKIMMER

10.28

SKIMMER

10.25

SKIMMER

8.45

8 PVC 8.89

8 PVC

6.48

8 PVC

8.34

BOTT SKIMM

8.66

ORIFICE 10X8

8.14

INV 8 PVC

8.01

INV 12 PLASTIC

PED

GA

10.33

GI

8.06

INV 15 CPP

10.30

GI

8.35

W INV12 CPP11.00

PROP TANK

11.38

PROP TANK

10.32

GI

7.81

INV N 12 CPP

7.61

INV E 12 CPP

7.53

INV W 15 CPP

X

XXXXXXXXXX

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X X X X X X X X X X X

X

X X X X X X X X

X X

X X

X X

X X

X X

X X

X X

X

XXX

X X

X X

X X

X

1 STORY BUILDING

F.F.E. = 12.12

EXIST MOTOR POOL

STORAGE BLDG.

2 STORY BUILDING

F.F.E. = 13.94

SHED

SHED

F.F.E.= 12.07

CONCRETE SIDEWALK

CONCRETE SIDEWALK

C O

N C

W

AL

K

C O

N C

S

ID

EW

AL

K

CONCRETE

CONCRETE

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

CONCRETE

CONCRETE

12TH STREET W

T H

A V

E N

U E

W

DY

H

X X

X

GATE

X

AS

PH

AL

T

R O

AD

W

AY

ASPHALT ROADWAY

C O

N C

W

AL

K

STEP

DN

DN

20'

14 14

5 14

LEGEND

CONC / ASPHALT / CURB TO BE REMOVED

DEMOLITION NOTES

1. ABI #07 MILL AND OVERLAY THE EAST PARKING LOT

AND NORTH 7 PARKING STALLS (1.5" WITH SP-12.5).

SEE SITE PLAN FOR NEW STRIPING.

2. ADA PARKING SPACE, ACCESSIBLE AISLE, AND HC

SIGN TO BE RELOCATED. SEE SITE PLAN FOR NEW

STRIPING

3. CROSSWALK TO BE REMOVED AND DISPOSED OF.

SEE SITE PLAN

4. CONCRETE SIDEWALK TO BE REMOVED AND

DISPOSED OF.

5. ABI #1 ASPHALT TO BE REMOVED FOR THE NORTH

AND WEST PAVEMENT TO INSTALL STORM DRAIN TO

THE POND. NEW ASPHALT TO BE INSTALLED. SEE

GRADING AND DRAINAGE PLAN

6. CONCRETE RAMP TO BE REMOVED AND DISPOSED

OF.

7. ASPHALT RAMP TO BE REMOVED

8. NOT USED

9. NOT USED

10. CLEAR VEGETATION AS REQUIRED FOR NEW STORM

LINE.

11. REMOVE INVASIVE PLANTS. MITERED END SECTION

BLOCKED / HOLDING WATER

12. CONC SIDEWALK RAMP TO BE REMOVED

13. CONC CURB TO BE REMOVED

14. REMOVE SHRUBS, ADD FILL AND RE-GRADE AREA TO

DRAIN AWAY FROM BUILDING

15. REMOVE 4'± OF EXISTING FE-7 FENCE FOR NEW 4'

SWING GATE.

16. REMOVE 20'± OF EXISTING K-8 FENCE FOR NEW 20'

ROLLING GATE.

17. REMOVE EXISTING FLAG POLE LIGHT FIXTURE AND

CONCRETE SLAB ONLY. FLAG POLE AND FOUNDATION

TO REMAIN / PROTECT. REFER TO A6.2 SHEET FOR

COMPLETE SCOPE OF WORK. PROTECT EXISTING

MEMORIAL STONE.

18. EXISTING UNIT SIGN TO BE RENOVATED. REFER TO

A6.2 SHEET FOR COMPLETE SCOPE OF WORK

19. WHEEL STOPS TO BE REMOVED AND DISPOSED OF.

(TYP)

2/ 5/

:1

6:

P M

Au to de sk

D oc s:

//1

0.

N

G A

D ad e C ity /1

0.

D

M A

C

FM

O D

AD

E

C

IT

Y

ES

P R

EN

O

VA

TI

O N

S.

rv t

C3.1

DEMOLITION PLAN

N

S

EW

15 30 60

SCALE: 1" = 30'

SHEET NO.:

PROJECT NO.:

DATE:

SHEET TITLE:

DRAWN BY:

REVISIONS:

RG

1910.09

JULY 10, 2025

PA

LM

ET

TO

E

SP

R

EN

O

VA

TI

O

N

4T

H A

VE

W

, P

AL

M

ET

TO

, F

L

N

AT

IO

N

AL

G

U

AR

D A

R M

O R

Y

D M

A C

FM

O

TREE LEGEND

SYMBOL NAME SYMBOL NAME

OAK PINE

PALM OTHER

NOTE: TREE SIZES IN INCHES

DEAD

0%

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IT

TA

L

ABI #07 MILL AND OVERLAY

A. IF ABI #07 IS NOT SELECTED POV PARKING LOT TO BE

SEALED AND STRIPED.

B. ANY ASPHALT THAT IS DAMAGED WILL REQUIRE

PATCHING PER THE ASPHALT PAVEMENT SPECIFICATIONS

ON SHEET C6.1

GENERAL NOTE

06/17/26 -

ADDENDUM # 2

10.94

PK

FLAGPOLE

PLAQUE MYRTLE 4 4

3 3

10.43

GI

8.21

INV S 15 RCP

MYRTLE 4 4

3 3

MYRTLE 4 4

3 3

MYRTLE 4 4

3 3

MYRTLE 5 4

3 4

10.35

GI

8.12

N INV 15 RCP

8.08

S INV 15 RCP

GA

PED

10.54

GI

7.96

N INV 15 RCP

8.06

S INV 15 RCP

36 30

MHS

11.80

MHS

11.65

16 16 15 15PED

GA

10.17

EBX

PED

MHS

10.01

10.38

BFP

10.29

BFP

10.34

ELEC OUTLET

22 18

1415 9

15 15

9.75

GI

6.70

INV E 15 RCP

6.72

INV NW 15 RCP

6.16

MES INV 15 RCP

10.24

SKIMMER

10.28

SKIMMER

10.28

SKIMMER

10.25

SKIMMER

8.45

8 PVC 8.89

8 PVC

6.48

8 PVC

8.34

BOTT SKIMM

8.66

ORIFICE 10X8

8.14

INV 8 PVC

8.01

INV 12 PLASTIC

PEDA/C

GA

A/C

10.33

GI

8.06

INV 15 CPP

10.30

GI

8.35

W INV12 CPP11.00

PROP TANK

11.38

PROP TANK

10.32

GI

7.81

INV N 12 CPP

7.61

INV E 12 CPP

7.53

INV W 15 CPP

X

XXXXXXXXXX

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X X X X X X X X X X X

X

X X X X X X X X

X X

X X

X X

X X

X X

X X

X X

X

XX

X X

X X

X X

X

1 STORY BUILDING

F.F.E. = 12.12

EXIST MOTOR POOL

STORAGE BLDG.

2 STORY BUILDING

F.F.E. = 13.94

SHED

SHED

F.F.E.= 12.07

CONCRETE SIDEWALK

CONCRETE SIDEWALK

C O

N C

W

AL

K

CONCRETE

CONCRETE

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

CONCRETE

CONCRETE

12TH STREET W

T H

A V

E N

U E

W

DY

H

X X

X

GATE

X

AS

PH

AL

T

R O

AD

W

AY

ASPHALT ROADWAY

C O

N C

W

AL

K

STEP

DN

DN

9 9

LAND USE

EXISTING MUNICIPAL

PARCEL ID

2804400059

PROJECT LOCATION

1107 14TH AVENUE W

PALMETTO, FLORIDA 34221

MANATEE COUNTY

FUTURE LAND USE

CITY

ZONING

P PUBLIC

LEGEND

CONCRETE SIDEWALK

ASPHALT PAVEMENT

1. WALKING SURFACES WITH A RUNNING SLOPE NOT STEEPER

THAN 1:20 (5%) AND A CROSS SLOPE OF 1:48 (2%).

2. WALKING SURFACES SHALL HAVE A MINIMUM CLEAR WIDTH

OF 36 INCHES AND A CLEAR WIDTH OF 48 INCHES AT ALL

TURNS AND WHEN SIDEWALKS CHANGE DIRECTION THERE

SHALL BE 5-FOOT FLAT AREA WITH A 1:48 (2%) MAXIMUM

SLOPE AT THE TRANSITION AREA.

3. MINIMUM WIDTH REQUIREMENT OF 32 INCHES FOR

DOORWAYS AND RAMPS SHALL COMPLY WITH

FBC-ACCESSIBILITY 405.

4. ALL COMPONENTS OF AN ACCESSIBLE ROUTE SHALL

COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC-A

SECTION 208 AND CHAPTERS 4 & 5.

5. SLOPES BETWEEN 5% AND 8.33% SHALL MEET THE RAMP

REQUIREMENTS OF ADA.

6. ACCESSIBLE PARKING AND ACCESS AISLES SHALL NOT

EXCEED 2% IN ANY DIRECTION.

7. INTERSECTING SIDEWALKS SHALL NOT EXCEED 2% IN ANY

DIRECTION.

8. ANY SLOPE GREATER THAN 8.33% SHALL NOT BE PART OF

AN ACCESSIBLE ROUTE.

ADA ACCESSIBLE NOTES

2/ 5/

:1

6:

P M

Au to de sk

D oc s:

//1

0.

N

G A

D ad e C ity /1

0.

D

M A

C

FM

O D

AD

E

C

IT

Y

ES

P R

EN

O

VA

TI

O N

S.

rv t

C4.1

SITE PLAN

N

S

EW

15 30 60

SCALE: 1" = 30'

SHEET NO.:

PROJECT NO.:

DATE:

SHEET TITLE:

DRAWN BY:

REVISIONS:

RG

1910.09

JULY 10, 2025

PA

LM

ET

TO

E

SP

R

EN

O

VA

TI

O

N

4T

H A

VE

W

, P

AL

M

ET

TO

, F

L

N

AT

IO

N

AL

G

U

AR

D A

R M

O R

Y

D M

A C

FM

O

TREE LEGEND

SYMBOL NAME SYMBOL NAME

OAK PINE

PALM OTHER

NOTE: TREE SIZES IN INCHES

DEAD

CONSTRUCTION NOTES

1. NEW 5' WIDE CONC SIDEWALK, 4" THICK.

SEE SHEET C6.1 FOR SIDEWALK DETAIL

2. NEW ADA COMPLIANT SIDEWALK RAMP W/

DETECTABLE WARNING

3. NEW 5' WIDE ADA AISLE

4. NEW 12' WIDE H/C PARKING SPACE

5. NEW H/C PARKING SIGN

6. NEW WHEEL STOPS (TYP)

7. ABI #7 MILL AND OVERLAY THE EAST

PARKING LOT AND NORTH 7 PARKING

STALLS (1.5" WITH SP-12.5).

8. NEW 6' WIDE CONC SIDEWALK

9. NEW 12" WIDE FLUSH CONC RIBBON CURB

10. NEW 4' WIDE GATE, 6' HIGH CLF. SEE FE-7

FENCE GATE DETAIL ON ARCHITECTURAL

FOR REQUIRED SPECIFICATION.

11. NEW 20' WIDE SWING GATE. SEE K-8 FENCE

DETAIL ON ARCHITECTURAL FOR

REQUIRED SPECIFICATION.

12. RENOVATED LED FLAG POLE LIGHT

FIXTURE AND CONCRETE SLAB. REFER TO

A6.2 SHEET FOR COMPLETE SCOPE OF

WORK.

13. RENOVATED UNIT SIGN. REFER TO A6.2

SHEET FOR COMPLETE SCOPE OF WORK.

14. ADD #57 STONE BETWEEN THE

MECHANICAL PADS AND BUILDING ACCESS

PADS

15. NEW CONCRETE RAMP

16. NEW ASPHALT RAMP

0%

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IT

TA

L

WHEEL STOP

12" WIDE FLUSH CONC RIBBON CURB

ABI #07 MILL AND OVERLAY

A. IF ABI #07 IS NOT SELECTED POV PARKING LOT TO BE

SEALED AND STRIPED.

B. ANY ASPHALT THAT IS DAMAGED WILL REQUIRE

PATCHING PER THE ASPHALT PAVEMENT SPECIFICATIONS

ON SHEET C6.1

GENERAL NOTE

06/17/26 -

ADDENDUM # 2

10.94

PK

.64

.72 11

.07

.01

.40

.12

.84

.56

.86 11 .07 11 .23

.46

.21

.12

.3

.96

.19

.93

.78

.40

.67

.35

.70

.37

.26

.00

.02

.0511 .0611

.06

.1 10

.90

.92 11 .08 11 .54

.4010

.8610 .72

.85

.30

.63

.91

.25

.44

.35

FLAGPOLE

PLAQUE

.4

.28

.03

.66

.00

.44

.37 11

.26

.36

.42

.38

.20

.22

.34

.4110 .6

.92

.05

.4

MYRTLE 4 4

3 3

.6

.84

.80

.77

.81

.5 11 .1

.96

.88 10 .5

.39

10.43

GI

8.21

INV S 15 RCP

.4

.38

.610 .90

.9611

.4

MYRTLE 4 4

3 3

MYRTLE 4 4

3 3

MYRTLE 4 4

3 3

.2

MYRTLE 5 4

3 4

.9

.00

.74

.5

.33

10.35

GI

8.12

N INV 15 RCP

8.08

S INV 15 RCP

.2910 .8

.92

.03

.211

.4

GA

PED

.24

.7

.8010 .9211

.0

.1

.8

.8

.89

.80

.8

.17

10.54

GI

7.96

N INV 15 RCP

8.06

S INV 15 RCP

.31 11

.15

.35

.40

.35

.33

.30

.25

.19

.26

.26

.25

.64

.63

.68

.41

.32

.85

.68

.46

.01

.310

.0

.8810 .3610

.6710 .17

.18

.18

.5

36 30 9.2

.6810 .02

.59

.49

.35

.76

.41

.33

.51

.50

.54

.31

.29

.52

.45

.52

.55 10 .62

.45

.34 10

.63

.69

.711 .02

.10

.53

.27

.74

.17

.69 10

.4

.6

.24

.77

.61

.63

.6611

.63

.64

.66

MHS

11.80

.74

.73

.71

.68 11 .79

.78

.72

.8011

.70

.77

.74

.68

.65

.60

.63

.58

.61

.67

MHS

11.65

.3310

.82

.05

.17

.1011

.07

.0910

.78

.93

.16

.22

.7

.00

.96

.7210

.61

.8010 .72

.47

.61

.83

.89

.6

.511

16 16 15 15

.65

.60

.5910

.39

.55

.55

.33

.48

.40

.37

.1

9.9

9.9

.2

PED

.34

.40

.2810

.03

.4010

.23

9.9

.14

.28

.23

9.8 9.7

.0

GA

10.17

EBX

PED10

.0

.16

.15

.059.9

.05

MHS

10.01

9.8

9.8

9.9

.24

.27

.2

.1

.4

.26

.21

9.7 79.6

9.8 39.7

9.6

9.7

.14

.17

.1

.4

.76

.75

.75

.76

.93

.7

.60

.58

.6010 .6910

.66

.65

.71

.68

10.38

BFP

10.29

BFP

.2

.4

.85 10 .88 10

.7

.82

.59

.66

.86

.9010 .91

.92

.82

.86

.6010

.76

.85

.04

.0

9.7 10 .5

.9210 .88

.77

.60

.5

.4

.52

.88

.9910

.67

.44

.32

.2

.0

.21

.39

.44

.39

.50

.42

.31

.1

.28

.36

.44

.85

.8

D

11.28

MH

.25

.30

.910

.97

.65

.29

.32

.1

.00

.67

.13

.72

.38

.04

.36

.56 11 .43

.10

.11

.21

.3110 .89

.0

.20

.86 10

.86

.20

.31

.27

.15

.13

.27

.92

.07

.12 11

.311 .30

.97

.1411

.1510 .94

.82

.9911 .30

.3

10.34

ELEC OUTLET

.75

.64

.49

.90

.0

.4

.1

.2

.54

.51

.66

.55

.1

.2

.2

.4

.2

.3

.1

.06

9.9

22 18

.8

.2

.10 10 .12

.3

.3

.2

.4

.6

.6

.4

.4

.6

.9

.6

.28

.34

.39

.9

.1

.66

.7

.6

.17 23

.6

.76

.70

.4

.5

.63

.5

1415 9

15 15

.3

.7

.4

9.75

GI

6.70

INV E 15 RCP

6.72

INV NW 15 RCP

8.9

6.16

MES INV 15 RCP

9.2

6.8

6.7 9.8

.66.5

.1

6.4

.8

.7

.2

.3

.3

10.32

CTRL STR

10.24

SKIMMER

10.28

SKIMMER

10.28

SKIMMER

10.25

SKIMMER

8.45

8 PVC 8.89

8 PVC

6.48

8 PVC

8.34

BOTT SKIMM

8.66

ORIFICE 10X8

8.14

INV 8 PVC

7.0

6.99.5

.6

.6

.1

6.7

6.8

9.7

.5

.8

.1

6.7

8.01

INV 12 PLASTIC

.4910 .50

.34

.30

.0

9.8

6.9

.01

.87

.69

.66

.08

.78

.1410 .76

.78

.88

.96

.93

.5

.5

.78

.85

.5

.96

.04

.08

.35

.44

.74

.27

.07

.06

.31

.3

.9011 .70

.65

.81

.4

.92

.8

.0

.1

.2

.0

.5

9.9

.8

.44

.67

.9511 .43

.08

.63

.78

.46

.50

.3

.64

.58 11

.38

.33

.36

.4911 .50

.51

.98

.49

.17

.07

.90

.19

.84

.92

.69

.68

.66

.60

.36

.46

.3

.310

.6

.4 10

.5

.6

.37

.1

PED

D

MH

11.14

A/C

.0GA10

.9

.2

.9

.2

D

MH

11.16

A/C11 .0

.6

.2

.80

10.33

GI

8.06

INV 15 CPP

.7

.92

.90

.61

.81

.8

.1

.88

.70

.47

.48

.54

.49

.54

.14

.15

.08

.6

10.30

GI

8.35

W INV12 CPP

.5

.89

.32

.11

.11

.17

.23

.05

11.00

PROP TANK

11.38

PROP TANK

.5

.50

.48

.28

.14

.00

.80

.2

10.32

GI

7.81

INV N 12 CPP

7.61

INV E 12 CPP

7.53

INV W 15 CPP

.35

.78

.211

.3

.5

.63

.84

.69

.71

.64

.86

.72

.69

.82

.53

.74

.7910

.84

.72

.74

.24

.68

.9810 .79

.64

.61

.1512 .24

.79

.8811

.26

.06

.22

.54D

11.12

MH12

.7811 .76

.7510

.8

D

11.17

MH

.64

.36

.70

.45

.83

.67

.60

.48 10 .60 11

.31

.00

.04

.30

.29

.46

.810 .5010 .56

.35

.6

.4

.46

.47

.49

.8

.78

.9

.48

.29

.24

.31

.40

.48

.1

X

XXXXXXXXXX

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X X X X X X X X X X X

X

X X X X X X X X

X X

X X

X X

X X

X X

X X

X X

X

XX

X X

X X

X X

X

1 STORY BUILDING

F.F.E. = 12.12

EXIST MOTOR POOL

STORAGE BLDG.

2 STORY BUILDING

F.F.E. = 13.94

SHED

SHED

F.F.E.= 12.07

CONCRETE SIDEWALK

CONCRETE SIDEWALK

C O

N C

W

AL

K

CONCRETE

CONCRETE

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

CONCRETE

CONCRETE

12TH STREET W

T H

A V

E N

U E

W

DY

H

X X

X

GATE

X

AS

PH

AL

T

R O

AD

W

AY

ASPHALT ROADWAY

C O

N C

W

AL

K

STEP

DN

DN

ST-01

ST-02

ST-06

10.55

10.65

10.25

11.40

11.67 TC

11.33 EP

11.24 TC

10.90 EP

10.82

8"RD

8"RD

8" R

D

8"RD

8" R

D

8" R

D 8"

R D

8"RD

2 2

ST-04

8"RD8"RD

8" R

D

ST-0510.40

4"RD

4"RD

6" R

D

PROP SWALE

10.20 10.00

ST-03

9.80

10.50 10.5010.40

10.50

10.50

10.40 10.35

DRAINAGE STRUCTURES

NO.

ST-01

ST-02

ST-03

ST-04

ST-05

ST-06

STRUCTURE DATA

FDOT TYPE "F" INLET

TOP= 10.55

15"(W) INV= 7.20

FDOT TYPE "F" INLET

TOP= 10.25

15"(E) INV= 6.80

18"(N) INV= 6.80

FDOT TYPE "C" INLET

BUBBLER OUTLET

TOP= 9.80

18"(S) INV= 6.55

STORM MH TYPE "P"

TOP= 11.02

18"(W) INV= 6.55

12" ADS YARD DRAIN

TOP= 10.40

6"(N) INV= 8.00

18" MES

TOP= 8.04

18"(E) INV= 6.40

LOCATION

N: 1159669.32 E: 467733.59

N: 1159661.44 E: 467545.94

N: 1159733.42 E: 467557.72

N: 1159554.37 E: 467532.33

N: 1159538.12 E: 467518.08

N: 1159552.76 E: 467465.14

STORM PIPE DATA

PIPE RUN

ST-01 TO ST-02

ST-02 TO ST-03

ST-04 TO ST-06

ST-05 TO

LENGTH

188'

73'

67'

15'

DIA & TYPE

15" N12 HDPE

18" N12 HDPE

18" N12 HDPE

6" N12 HDPE

SLOPE

0.21%

0.34%

0.22%

7.97%

LEGEND

ROOF DRAIN (SIZE PER PLAN)

@ 1% MIN SLOPERD

6" PVC ROOF DRAIN

@ 1% MIN SLOPE

2/ 5/

:1

6:

P M

Au to de sk

D oc s:

//1

0.

N

G A

D ad e C ity /1

0.

D

M A

C

FM

O D

AD

E

C

IT

Y

ES

P R

EN

O

VA

TI

O N

S.

rv t

C5.1

GRADING & DRAINAGE PLAN

N

S

EW

15 30 60

SCALE: 1" = 30'

RG

1910.09

JULY 10, 2025

PA

LM

ET

TO

E

SP

R

EN

O

VA

TI

O

N

4T

H A

VE

W

, P

AL

M

ET

TO

, F

L

N

AT

IO

N

AL

G

U

AR

D A

R M

O R

Y

D M

A C

FM

O

TREE LEGEND

SYMBOL NAME SYMBOL NAME

OAK PINE

PALM OTHER

NOTE: TREE SIZES IN INCHES

DEAD

CONSTRUCTION NOTES

1. CLEAN AND FLUSH OUT EX STORM INLETS

AND PIPES

2. REPLACE EXISTING GROUND LEVEL

TRANSITION COUPLINGS TO THE EXISTING

ROOF DRAIN CONNECTIONS (10 TOTAL)

3. CONNECT ALL ROOF DRAINS TO STORM.

CUT ASPHALT/CONC/BASE AS NECESSARY

TYPICAL.

4. CONNECT ALL A/C DRAINS TO STORM

TYPICAL.

5. REMOVE SHRUBS, ADD FILL AND RE-GRADE

AREA TO DRAIN AWAY FROM BUILDING.

SHEET NO.:

PROJECT NO.:

DATE:

SHEET TITLE:

DRAWN BY:

REVISIONS:

0%

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IT

TA

L

06/17/26 -

ADDENDUM # 2

2/ 5/

:1

6:

P M

Au to de sk

D oc s:

//1

0.

N

G A

D ad e C ity /1

0.

D

M A

C

FM

O D

AD

E

C

IT

Y

ES

P R

EN

O

VA

TI

O N

S.

rv t

C6.1

DETAILS

SHEET NO.:

PROJECT NO.:

DATE:

SHEET TITLE:

DRAWN BY:

REVISIONS:

RG

1910.09

JULY 10, 2025

PA

LM

ET

TO

E

SP

R

EN

O

VA

TI

O

N

4T

H A

VE

W

, P

AL

M

ET

TO

, F

L

N

AT

IO

N

AL

G

U

AR

D A

R M

O R

Y

D M

A C

FM

O

(COORDINATE WITH PLUMBING

PLANS FOR CONNECTION)

4', 5' OR 6' (TYP)

NEW BUILDING PAD

(TYP.)

BETWEEN EXP. JT. (TYP)

50' MAX. SPACING

NOTES:

1. ALL SIDEWALKS SHALL BE 4" THICK, 3,000 PSI

2. FIBER MESH REINFORCEMENT MAY BE USED

IN LIEU OF WIRE MESH. USE 1.5 POUNDS PER

CUBIC YARD TYPE III SYNTHETIC FIBER (ASTM

C1116-95).

3. GROUND IS TO BE COMPACTED PRIOR TO

POURING (TOP 6" @ 95% MOD. PROCTOR)

4. ALL EXPOSED EDGES TO BE CHAMFERED.

5. WHERE SIDEWALK ABUTS PAVEMENT

THICKEN TO 6" OVER 3'.

6. CONTRACTION JOINTS SHALL BE SPACED @

4' INTERVALS FOR 4' SIDEWALKS, 5'

INTERVALS FOR 5' SIDEWALKS AND 6'

INTERVALS FOR 6'-0" SIDEWALKS.

7. CONTRACTION JOINTS SHALL BE 1" DEEP

AND EDGED WITH 1/8" RADIUS.

8. 1/2" EXPANSION MATERIAL REQUIRED WHERE

CONCRETE SIDEWALK ABUT CONCRETE

STRUCTURE, CURB, OR PAVEMENT.

9. A LAYER OF 15# FELT IS REQUIRED BETWEEN

WALK AND ADJACENT PARALLELING

CONCRETE CURB.

10. ALL ACCESSIBLE ROUTES ARE TO BE IN

STRICT ACCORDANCE WITH STATE OR

FEDERAL ADA REQUIREMENTS, WHICHEVER

IS STRICTER.

STANDARD PAVEMENT

1. 2" TYPE SP 12.5 ASPHALTIC SURFACE COURSE

2. 10" CRUSHED CONCRETE (125 LBR) or 6" SOIL CEMENT (300 psi MIN)

NTS

ASPHALT PAVEMENT SECTION

1 2

1/2" EXPANSION JOINT (TYP)

1/4" EXPANSION JOINT (TYP)

CONTRACTION

JOINT (TYP)

4', 5' OR 6'

NTS

TYPICAL SIDEWALK DETAIL

0%

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

T

SU

BM

IT

TA

L

12"

NTS

CONCRETE RIBBON CURB

MIN. 12" COMPACTED SUBGRADE

(98% MODIFIED PROCTOR)

EXISTING SUBGRADE CAN BE USED,

HOWEVER WILL NEED TO BE COMPACTED

ACCORDINGLY TO THE SPECIFICATION

06/17/26 -

ADDENDUM # 2

File details come from the government source that posted it. Updated .