1604000 J Wastewater.pdf

PDF 139 KB Posted

Attached to
NAVAL RESEARCH LABORATORY (NRL) FACILITY SUPPORT SERVICES (FSS)
Solicitation number
N4008027R1001
Issued by

About this file

This document is Section J of a federal contract solicitation addressing Wastewater system maintenance and management requirements.

The section contains four attachments that establish the technical framework for wastewater collection system operations. Attachment J-1604000-01 provides definitions and acronyms relevant to wastewater management, including references to standards organizations (ANSI, AWWA, NASSCO) and regulatory frameworks (DoD FGS, FAC, NPDES). Attachment J-1604000-02 lists eight technical reference documents that govern wastewater system design and operation, including UFC (Unified Facilities Criteria) standards for wastewater treatment, collection, gravity sewers, and industrial/oily wastewater control, along with military handbooks and engineering criteria. Attachment J-1604000-03 specifies that the Contractor must develop and implement a Preventive Maintenance Program for the Wastewater Collection Systems and all mechanically and electrically interlocked ancillary components including aerators, air compressors, alarms, generators, pumps, lift stations, clarifiers, control panels, sensors, tanks, and monitoring systems. The wastewater collection system comprises approximately 15,570 linear feet of gravity mains, 7,955 linear feet of force mains, multiple mechanically equipped lift stations, and approximately 141 sanitary manholes distributed across four primary facility zones, with pipe sizes ranging from less than four inches to 30 inches. Attachment J-1604000-04 references a separate Spill Containment Plan document without providing specific details in this section.

View the file

Other files

File Type Posted
0100000 C General Information.pdf PDF
1602000 C Electrical.pdf PDF
1604000 C Wastewater.pdf PDF
1601000 C Utility Management.pdf PDF
Attachment J-0200000-05(e) Solid Waste Management Report.pdf PDF
1502000 J Facility Investment.pdf PDF
Attachment J-1502000-05 HVAC and Refrigeration Systems.xlsx XLSX spreadsheet
Attachment J-1502000-07 Interior and Exterior Lighting Systems.xlsx XLSX spreadsheet
Attachment J-1502000-10 Lightning Arrestors and Grounding Devices.xlsx XLSX spreadsheet
Attachment J-1502000-13 Auxiliary Generator Systems.xlsx XLSX spreadsheet
Attachment J-1502000-16 POL Systems.xlsx XLSX spreadsheet
Attachment J-1502000-22 Emergency Lighting Systems.xlsx XLSX spreadsheet
Attachment J-1502000-31 Mass Communication Systems.xlsx XLSX spreadsheet
1503030 J Integrated Solid Waste Management.pdf PDF
1503060 J Pavement Clearance.pdf PDF
Attachment J-1601000-04 (c)- NRL Update Utility Drawings - Chilled Water.pdf PDF
Attachment J-1601000-10 Electrical Assets.xlsx XLSX spreadsheet
Attachment J-1601000-13 UEM-DI Meter Group and the Direct Condition Rating.pdf PDF
1502000 C Facility Investment.pdf PDF
1503030 C Integrated Solid Waste Management.pdf PDF
1503060 C Pavement Clearance.pdf PDF
1606000 C Water.pdf PDF
Attachment J-0200000-04 NAVFAC 4330 INVOICE FORM.xlsx XLSX spreadsheet
Attachment J-0200000-05(b) Form Contractor Significant Incident Report.pdf PDF
Attachment J-0200000-05(f) Directions for Process Material Log Sheets.pdf PDF
Attachment J-0200000-05(j) Crane and Rigging Gear Accident Report.pdf PDF
Attachment J-0200000-11 MAXIMO Data Reporting.pdf PDF
Attachment J-0200000-15 ELINs Blank.xlsx XLSX spreadsheet
1501000 J Facility Management.pdf PDF
Attachment J-1501000-04 - NRL Site Map.pdf PDF
Attachment J-1502000-01 Definitions and Acronyms.pdf PDF
Attachment J-1502000-03 Sample of E_U_R Orders.pdf PDF
Attachment J-1502000-08 Boilers and UPVs.xlsx XLSX spreadsheet
Attachment J-1502000-12 Compressed Air.xlsx XLSX spreadsheet
Attachment J-1502000-19 Manual and Automated Doors.xlsx XLSX spreadsheet
Attachment J-1502000-21 Emergency Eye Wash and Emergency Showers.xlsx XLSX spreadsheet
Attachment J-1502000-24 Exhaust Hood and Duct Systems.xlsx XLSX spreadsheet
Attachment J-1502000-26 Boiler Water Testing and Treatment.xlsx XLSX spreadsheet
Attachment J-1502000-30 Miscellaneous Equipment.xlsx XLSX spreadsheet
Attachment J-1502000-32 Installation Facilities Monitoring.pdf PDF
1601000 J Utilities Management.pdf PDF
Attachment J-1601000-01 Points of Demarcation.pdf PDF
Attachment J-1601000-04 (b)- NRL Update Utility Drawings - Domestic Water.pdf PDF
Attachment J-1601000-04 (d) NRL 13.8KV SINGLE LINE REV-11.pdf PDF
Attachment J-1601000-08 Utility Asset Tagging Guidance.pdf PDF
Attachment J-1601000-12 Water Assets.xlsx XLSX spreadsheet
1501000 C Facility Management.pdf PDF
0200000 J Management and Administration.pdf PDF
Attachment J-0200000-02 Wage Determination.pdf PDF
Attachment J-0200000-05(c) SECNAV Form 5512-1.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Section J – 1604000 Wastewater

Attachment Number Attachment Title

J-1604000-01 Definitions and Acronyms J-1604000-02 References and Technical Documents J-1604000-03 Wastewater System Description and Inventory J-1604000-04 Spill Containment Plan

Attachment J-1604000-01 Definitions and Acronyms

Title Description ANSI American National Standards Institute AWWA American Water Works Association DoD FGS Department of Defense Environmental Final Governing Standards FAC Florida Administrative Code NASSCO National Association of Sewer Service Companies NPDES National Pollutant Discharge Elimination System SOP Standard Operating Procedures UFC Unified Facilities Criteria

Attachment J-1604000-02 References and Technical Documents

Reference Title EI 11C201 Wastewater Collection and Pumping MO-209 Engineering Criteria MIL-HDBK-1005/9 Industrial and Oily Wastewater Control UFC 3-240-02N Wastewater Treatment Systems UFC 3-240-04A Wastewater Collection UFC 3-240-07FA Sanitary and Industrial Wastewater Collection: Gravity Sewers and Appurtenances UFC 3-240-09FA Domestic Wastewater Treatment UFC 4-832-01N Design: Industrial and Oily Wastewater Control

Attachment J-1604000-03 Wastewater Systems Description and Inventory

The Contractor shall develop and implement an Preventive Maintenance Program for the Wastewater Collection Systems and all mechanically and electrically interlocked ancillary parts, equipment and components of the Wastewater Collection Systems; such as: aerators, air compressors, alarm devices, antennas, auxiliary generators, backflow prevention devices, barminutor, blowers, clarifiers, comminutor, control panels, ejectors, electric motors, filters, gauges, lift stations, meters, mixers, nozzles, overcurrent devices, piping, pumps, receivers, sensors, tanks, transmitters, valves, monitoring and controls systems, etc.

Wastewater Collection Systems Description

The wastewater collection system pipes size range from less than four inches to 30 inches. The total length of the sewer collection system is about 15,570 linear feet of gravity mains, 7.,955 linear feet of force mains, multiple mechanically equipped lift stations and about 141 sanitary manholes distributed across four primary facility zones.

Attachment J-1604000-04 Spill Containment Plan

Attachment J-1604000-04 Spill Containment Plan is attached.

File details come from the government source that posted it. Updated .