This document is an architectural drawing detailing roof and hangar door construction specifications for Gateway National Recreation Area at Floyd Bennett Field. The drawing sheet (A5.0.2) contains nine detailed construction sections addressing parapet walls, hangar doors, roof assemblies, and drainage systems.

The specifications require installation of multi-layer roof systems incorporating hot-applied rubberized asphalt, polyester and fiberglass reinforcing sheets, polyurethane base and top coats, rigid insulation with tapered layers for slope creation, and roof coverboard over existing concrete decks. Hangar door work includes cleaning and painting existing upper tracks, removing and reinstalling aluminum panels with aluminum rivets, replacing rolling wheels with historic in-kind replacements, and installing neoprene and nylon brush weatherstripping. Copper components throughout include scuppers, counter flashing, coping, conductor heads, downspouts, and corrugated copper sheathing, all requiring matching of existing profiles and sizes. Roof drainage details specify drain bodies with perforated extensions, clamp rings, and deck clamps positioned at specified on-center spacing with overflow drains set 2 inches minimum above main drains. The contractor is required to verify all existing field dimensions, completely remove hangar doors from tracks for restoration, review salvaged door wheels for reusable parts, and ensure all doors are reinstalled to full operability. Wood blocking, plywood substrates, and exterior-grade tongue-and-groove wood decking require installation or replacement as specified in related structural drawings.

View the file

Other files

File Type Posted
Sol_140P2026R0060_Amd_0004.pdf PDF
28_20_00_Video_Surveillance_-_06_23_26_0003.pdf PDF
A3-0_-_BUILDING_SECTIONS_06_23_26_0003.pdf PDF
Sol_140P2026R0060_Amd_0003.pdf PDF
Sign-in_Sheet_for_06_16_26_Site_Visit_0003.pdf PDF
FINAL_BID_QUESTIONS_AND_ANSWERS__UPDATED_06_23_26_0003.pdf PDF
GATE_308504_-_140P2026R0060_Bid_Questions_and_Answers_-_06_11_26_0002.docx DOCX document
B08_Solicitation_P2026R0060_Revisions_to_Section_L_06_11_26_0002.docx DOCX document
S2-6_-_WPA_INFILL_ROOF_FRAMING_PLAN_06_11_26_0002.pdf PDF
012700_DefinitionOfContractLineItems_Revised_06_11_26_0002.pdf PDF
G0_-_COVER_SHEET_06_11_26_0002.pdf PDF
Sol_140P2026R0060_Amd_0002.pdf PDF
B08_Fillable_Past_Performance_Questionnaire_0002.docx DOCX document
A0-4_-_EXTERIOR_ELEVATIONS_-_DEMOLITION_06_11_26_0002.pdf PDF
Solicitation_P2026R0060_GATE_308504_Contract_Price_Schedule_Revised_06_11_26_0002.xlsx XLSX spreadsheet
A0-6_-_EXISTING_CONDITIONS_PHOTOS_-_EXTERIOR_06_11_26_0002.pdf PDF
B08_Fillable_Project_Experience_Questionnaire_0002.docx DOCX document
S6-3_-_MASONRY_REPAIR_AND_LINTEL_REPLACEMENT_DETAILS_06_11_26_0002.pdf PDF
S6-5_-_TYPICAL_CONCRETE_REPAIR_DETAILS_06_11_26_0002.pdf PDF
A4-2-1_-_ENLARGED_ELEVATIONS_-_HANGAR_4_DOORS_06_11_26_0002.pdf PDF
S6-2_-_STEEL_BEAM_REPAIR_DETAILS_06_11_26_0002.pdf PDF
WD_NY20260003_05_26_26_-_Issued_06_11_26_0002.pdf PDF
P4_-_PLUMBING_SCHEDULES_06_11_26_0002.pdf PDF
Sol_140P2026R0060_Amd_0001.pdf PDF
Amendment_0001_P2026R0060_0001.pdf PDF
Sol_140P2026R0060.pdf PDF
1__25-1219_GATE_308504_Final_CD_Project_Specifications.pdf PDF
3_25-1219_GATE_308504_Final_CD_Structural_Design_Calculations.pdf PDF
B08_GATE_308504_Hangars_3_and_4_Solicitation_140P2026R0060.pdf PDF
2_Final_CD_Drawings_-_Condensed.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COPPER SCUPPER

TO MATCH

EXISTING.

SEALANT.

TERMINATION BAR

FASTENED 8" O.C.

COPPER COUNTER

FLASHING - LAP JOINTS

3" - EMBED AND SEAL

IN EXISTING JOINT.

TAPER INSULATION TO

MEET EXISTING

SCUPPER LOCATION.

1/2" PLYWOOD.

9"

6" DIA

NOM 2X WOOD

BLOCKING

COPPER

CONDUCTOR

HEAD AND

DOWNSPOUT TO

MATCH

EXISTING.

COPPER

CONDUCTOR

HEAD AND

DOWNSPOU

T TO MATCH

EXISTING.

COPPER

SCUPPER TO

MATCH

EXISTING.

POLYURETHANE TOP COAT.

FIBERGLASS REINFORCING SHEET.

POLYURETHANE BASE COAT.

HOT APPLIED

RUBBERIZED ASPHALT.

POLYESTER

REINFORCING SHEET.

1/2" ROOF

COVERBOARD.

2 1/2" RIGID

INSULATION.

10 MIL POLYETHYLENE

VAPOR BARRIER

EXISTING CONCRETE

DECK TO REMAIN.

POLYURETHANE TOP COAT.

FIBERGLASS REINFORCING

SHEET.

POLYURETHANE BASE COAT.

HOT APPLIED RUBBERIZED

ASPHALT.

POLYESTER REINFORCING

SHEET.

1/2" ROOF COVERBOARD.

2 1/2" RIGID INSULATION.

TAPER TOP LAYER TO

CREATE 1/4":12" SLOPE.

10 MIL POLYETHYLENE

VAPOR BARRIER

EXISTING CONCRETE

DECK TO REMAIN.

CANT STRIP.

VIF

2' - 6 1/2" ±

V

IF

2X NOM. WOOD BLOCKING.

EXISTING CURB.

CONTRACTOR TO VIF DIMS.

6" DIA 6" DIA

MATCH EXISTING. VIF.

3' - 0" O.C.

POLYURETHANE TOP COAT.

FIBERGLASS REINFORCING SHEET.

POLYURETHANE BASE COAT.

HOT APPLIED RUBBERIZED ASPHALT.

POLYESTER REINFORCING SHEET.

1/2" ROOF COVERBOARD.

2 1/2" RIGID INSULATION. TAPER FOR

SLOPE.

DRAIN BODY AND

ACCESSORIES.

PERFORATED

EXTENSION.

CLAMP RING.

DECK CLAMP. NOTE: SEE WPA AND BOILER ROOM DETAILS

FOR DECK MATERIALS. OVER FLOW DRAIN

SET 2" MIN ABOVE MAIN DRAIN.

6" DIA

POLYURETHANE TOP COAT.

FIBERGLASS REINFORCING SHEET.

POLYURETHANE BASE COAT.

HOT APPLIED RUBBERIZED ASPHALT.

POLYESTER REINFORCING SHEET.

1/2" ROOF COVERBOARD.

2 1/2" RIGID INSULATION. TAPER FOR

SLOPE.

1/2" PLYWOOD.

2X8 T&G WOOD DECK.

DRAIN BODY AND ACCESSORIES.

PERFORATED EXTENSION.

CLAMP RING.

DECK CLAMP.

POLYURETHANE TOP COAT.

FIBERGLASS REINFORCING

SHEET.

1/2" PLYWOOD

1/2" ROOF COVERBOARD.

2 1/2" RIGID INSULATION.

2"X8" EXTERIOR GRADE T&G

WOOD BOARD TO MATCH

EXISTING.

POLYURETHANE BASE COAT.

HOT APPLIED RUBBERIZED

ASPHALT.

POLYESTER REINFORCING

SHEET.

TERMINATION BAR FASTENED 8" O.C.

COPPER COUNTER FLASHING - LAP JOINTS

3" - EMBED AND SEALANT IN EXISTING JOINT.

SEALANT.

COPPER COPING TO MATCH EXISTING

IN SIZE AND PROFILE.

FORMED COPPER

SHEET TRIM. IF

REPLACEMENT IS

REQUIRED (REFER TO

ELEVATIONS) PROFILE

TO MATCH EXISTING.

FASTEN TO WOOD

BLOCKING BEHIND

USING STAINLESS

STEEL FASTENERS.

CORRUGATED

COPPER SHEATHING

06-06

: HANGAR 3 ONLY

07-15

:TYP ALL HANGAR

DOORS

08-02.RW

05-23

/2

05-24

3" ±

06-04 M

IN3

07-32

05-10

06-06

:HANGAR 3 ONLY

WPA INFILL FLR

±-0' - 0 7/16"

07-14

/2

REFER TO

STRUCTURAL

FOR SILL TRACK

REPAIR SCOPE

:TYP ALL

HANGAR

DOORS

08-02.RW

08-01

HANGAR DOOR

WHEELS, EXISTING

CONDITION

CONTRACTOR TO REVIEW

EXISTING SALVAGED HANGAR

DOOR WHEELS FOR SOUND

PARTS BEFORE CREATING

REPLICA WHEELS.

1. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS IN

FIELD.

2. ALL HANGAR DOORS SHOULD BE REMOVED COMPLETELY

FROM THEIR TRACKS FOR RESTORATION.

3. REFER TO STRUCTURAL DRAWINGS FOR

REPLACEMENT/REPAIR OF HANGAR DOOR STRUCTURAL

MEMBERS.

4. HANGAR DOORS ARE TO BE REINSTALLED TO BE FULLY

OPERABLE.

5. FOR HANGAR DOOR STRUTURAL MEMBER REPAIRS, SEE

DETAILS ON STRUCTURAL DRAWINGS.

SHEET NOTES

SCALE AA5.0.2

6 LEAN TO THRU PARAPET SCUPPER DETAIL

DATE:

DESIGNED:

TECH. REVIEW:

SUB SHEET NO.

PMIS/PKG NO.

DRAWING NO.

SHEET

TITLE OF SHEET

OF

190066

GATE 308504

GATEWAY NATIONAL RECREATION AREA

CT

SW

AK

10/17/2025

/1

/2

:1

:1

P M

A u to d e s k D o c s /G

A T

E F lo y d B e n n e tt F ie ld

/G A

T E

F lo y d B e n n e tt F ie ld

R

.r v t

A5.0.2

ROOF & HANGAR DOOR

DETAILS

SCALE AA5.0.2

7 LEAN TO SCUPPER ELEVATION

SCALE AA5.0.2

4 BOILER ROOM ROOF DETAIL

SCALE AA5.0.2

5 BOILER ROOM ROOF OPENING DETAIL

SCALE OF FEET

6"12" 0" 1'

SCALE AA5.0.2

8 WPA ROOF DRAIN DETAIL

SCALE AA5.0.2

9 DOOR POCKET ROOF DRAIN DETAIL

SCALE AA5.0.2

1 HANGAR PARAPET WALL DETAIL

SCALE AA5.0.2

2 HANGAR DOOR - HEAD - TYP

SCALE AA5.0.2

3 HANGAR DOOR - SILL - TYP

KEYNOTES

KEY

VALUE TEXT

05-10 INSTALL CORRUGATED COPPER SHEETING

TO MATCH EXISTING.

05-23 CLEAN, PRIME AND PAINT EXISTING UPPER

HANGAR DOOR TRACKS TO ENSURE FULL

DOOR OPERABILITY. SEE STRUCTURAL.

05-24 FORMED COPPER SHEET TRIM. IF

REPLACEMENT IS REQUIRED (REFER TO

ELEVATIONS) PROFILE TO MATCH EXISTING.

FASTEN TO WOOD PLANKING BEHIND USING

STAINLESS STEEL FASTENERS.

06-04 INSTALL REPLACEMENT WOOD PLANKING

SUBSTRATE. ASSUME 1X6 BOARDS.

06-06 AT HANGAR 3, ASSUME THERE IS 2 X

TREATED WOOD BLOCKING AT ALL VERTICAL

AND HORIZONTAL FRIEZE TRUSS ELEMENTS,

AS WELL AS ALONG THE BOTTOM OF THE

TRUSS. REPLACE 100%.

07-14 3/16" NEOPRENE CONTINUOUS

WEATHERSTRIPPING WITH POWDER COATED

ALUMINUM RETAINER AND ALUMINUM RIVET

FASTENERS. POWDER COATING COLOR TO

MATCH HANGAR DOORS. VERIFY REQUIRED

NEOPRENE WIDTH IN FIELD.

07-15 NYLON BRUSH 90 DEGREE CONTINUOUS

WEATHERSTRIPPING WITH POWDER COATED

ALUMINUM RETAINER AND ALUMINUM RIVET

FASTENERS. POWDER COATING COLOR TO

MATCH HANGAR DOORS. VERIFY REQUIRED

NYLON BRUSH WIDTH IN FIELD. TRIM IF

NECESSARY ACCORDING TO

MANUFACTURER'S INSTRUCTIONS.

07-32 CONTINUOUS COPPER SHEET FLASHING

WITH DRIP EDGE ALONG ENTIRE LENGTH OF

FACADE. FASTEN TO WOOD PLANK

SUBSTRATE WITH STAINLESS STEEL

FASTENERS.

08-01 REMOVE EXISTING ALUMINUM PANEL. STRIP

EXISTING PAINT. SHOP PRIME AND PAINT.

REINSTALL WITH ALUMINUM RIVETS TO

MATCH EXISTING HISTORIC FASTENERS.

PRIME AND PAINT RIVETS TO MATCH.

08-02.RW REPLACE EXISTING ROLLING WHEEL WITH

IN-KIND REPLACEMENT HISTORIC ROLLING

WHEEL AND HARDWARE.

SCALE A

Sheets
A5.0.2 - ROOF & HANGAR DOOR DETAILS

File details come from the government source that posted it. Updated .