This is an architectural drawing sheet depicting exterior elevation demolition plans for a hangar facility at Gateway National Recreation Area's Floyd Bennett Field. The document shows four elevation views (North, South, East, and West) at Scale A, illustrating the current condition of the structure with detailed keynotes and specifications.
The demolition scope includes removal of two existing overhead coiling doors on the north elevation, while existing concrete masonry unit (CMU) infill walls are designated to remain. The drawings establish baseline elevations for the hangar and lean-to floors at ±0'-0", with hangar roofs at ±33'-4 1/16" and lean-to roofs at ±14'-7 11/16". Additional work identified includes exterior masonry wall rebuilds and window repair/replacement as detailed on the new work elevations and window schedule. The document is part of a larger project set (Drawing No. 190066, PMIS/PKG No. 646, Sheet 33 of 153) prepared for the National Park Service Gateway National Recreation Area facility.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HANGAR AND
LEAN-TO FLOORS
±0' - 0"
WPA INFILL ROOF
±20' - 9 29/32"
HANGAR ROOFS
±33' - 4 1/16"
LEAN-TO ROOFS
±14' - 7 11/16"
A0.5
02-18
A0.5
123456
OPEN
TWO (2) SLIDING HANGAR
DOORS DO NOT EXIST.
HANGAR AND
LEAN-TO FLOORS
±0' - 0"
WPA INFILL ROOF
±20' - 9 29/32"
HANGAR ROOFS
±33' - 4 1/16"
LEAN-TO ROOFS
±14' - 7 11/16"
02-18
A0.5
A0.5
1 2 3 4 5 6
HANGAR AND
LEAN-TO FLOORS
±0' - 0"
HANGAR ROOFS
±33' - 4 1/16"
LEAN-TO ROOFS
±14' - 7 11/16"
ABCDEFGHIJ
02-29
HANGAR AND
LEAN-TO FLOORS
±0' - 0"
HANGAR ROOFS
±33' - 4 1/16"
LEAN-TO ROOFS
±14' - 7 11/16"
A B C D E F G H I J
1. ALL EXTERIOR MASONRY WALL REBUILD
SCOPE IS INDICATED ON THE NEW WORK
ELEVATIONS.
2. SEE NEW WORK EXTERIOR ELEVATIONS AND
WINDOW SCHEDULE FOR REPAIR/REPLACEMENT
WINDOW SCOPE.
SHEET NOTES
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
190066
GATE 308504
GATEWAY NATIONAL RECREATION AREA
CT
SW
AK
10/17/2025
/9
/2
:4
:1
P
M A u to d e s k D o c s /G
A T
E F lo y d B e n n e tt F ie ld
/G A
T E
F lo y d B e n n e tt F ie ld
R
.r v t
A0.4
EXTERIOR ELEVATIONS -
DEMOLITION
SCALE AA0.4
1 ELEVATION - DEMO NORTH
SCALE AA0.4
2 ELEVATION - DEMO SOUTH
SCALE AA0.4
3 ELEVATION - DEMO EAST
SCALE AA0.4
4 ELEVATION - DEMO WEST
KEYNOTES
KEY
VALUE TEXT
02-18 REMOVE EXISTING OVERHEAD
COILING DOORS.
02-29 EXISTING CMU INFILL TO
REMAIN.
016 16 328
SCALE OF FEET
SCALE A
| Sheets |
| A0.4 - EXTERIOR ELEVATIONS - DEMOLITION |
| A0.6 - EXISTING CONDITIONS PHOTOS - EXTERIOR |
| A4.2.1 - ENLARGED ELEVATIONS - HANGAR 4 DOORS |