Vol2_Drawings_Final_Construction_Documents_June_2021_0002.pdf
PDF 14 MB Posted
- Attached to
- GRCA - 229035 Phantom Ranch Wastewater Treatment P Federal contract opportunity
- Solicitation number
- 140P2021R0127
About this file
This document provides details on a federal contract opportunity for wastewater treatment plant improvements. The solicitation is number 140P2021R0127 for GRCA - 229035 Phantom Ranch Wastewater Treatment Plant Short Term Improvements through the Department of the Interior National Park Service National Office. Offerors are invited to bid on providing construction services to upgrade the existing wastewater treatment plant at Phantom Ranch in Grand Canyon National Park, as outlined in the construction drawings file Vol2_Drawings_Final_Construction_Documents_June_2021_0002.pdf. The improvements aim to address capacity issues and bring the facility into compliance with environmental regulations. The response deadline has not been specified, nor has the planned award date. No other terms or conditions are included in this document.
View the file
Other files for this federal contract opportunity
Show all 33
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K
M
44PRV
12200
NOTES:
NOTES:
S
44FV
12400
5/1 9/2
1 1 6:5
5 N H0
R2
1 C :\P
W _W
OR
KD
IR
\D
EN
3\C H2
MH
ILL
_N H0
8\D
3\1 0D
0_
D3
.D W
G
XR
EF
S:
D0
\X
G-
BO
RD
ER
.D W
G;
D0
\X D-
NE
W
-H
DW
RK
S_
PL
N.
DW
G;
D0
\X
S-
HD
W
RK
S_
PL
N-
.D W
G;
D0
\X S-
HD
W
RK
S_
PL
N-
.D
W G;
PI
LSH
PRV
PI
3.0000
BLOWER AIR
(2" G.S.P.)
INV. EL. 56.10
HWL 56.00
EQUALIZATION
TANK
AERATION
TANK
2"PVC
SLUDGE RETURN (OR
WASTE) PUMPS
2"PVC
EQUALIZATION PUMPS
BLOWER AIR
(2" G.S.P.)
HWL 56.00
4'-9" TOTAL LENGTH
OF SWING ARM
HWL 56.00
4"x3" REDUCING
ELBOWS
AEROBIC
DIGESTER
4" FLARED
LONG-RADIUS
90° BEND
AEROBIC
DIGESTER
2"G.S.P.
PLUG TOP LEG
OF TEE
S.S.U-BOLT
SLUDGE TRANSFER
PUMP SWING JOINT
2"PVC
SIGHT
GLASS
BRACKET EQ. TO
UNISTRUT P1775
8"Øx31
2" S.S.
EXPANSION
ANCHORS
TO SUMP
3.0000
5/1 9/2
1 1 6:5
4 N H0
R2
1 C :\P
W _W
OR
KD
IR
\D
EN
3\C H2
MH
ILL
_N H0
8\D
3\2 0D
1_
D3
.D W
G
XR
EF
S:
D0
\X
G-
BO
RD
ER
.D W
G;
D0
\X D-
NE
W
-S
TP
-S
CN
-0 1.D
W G;
SUMP
PUMPS
CHEMICAL STORAGE
BINS.
2" PVC
4" PVC
SUMP
TO EQ. TANK
SUMP
2" PVC
UNIONS
SUMP PUMPS
BLOWER #2 BLOWER #1
BLOWER
#3
MANOMETERS
TO AEROBIC
DIGESTER
TO AERATION TANK
2.0000
T 4" D.I.P.
2" SCHED. 80 PVC
CONCRETE
FILL
GRAVITY
DRAIN TO
SUMP
SCUM REMOVAL
THROTTLING VALVE
INLET BAFFLE (2 PRESSURE.
TREATED 2"x12"x4'-3" 'S' & 1-2"x6"x4'-3")
INLET TROUGH
OVERFLOW WEIR
SCUM BAFFLE (PRESSURE
TREATED 2"x6"x4'-3")
SCUM TROUGH
MAX. W.L.
55.45
4" OVERFLOW
PIPE
ALUMINUM GRATING
5/1 1/2
1 1 7:3
6 N H0
R2
1 C :\P
W _W
OR
KD
IR
\D
EN
3\C H2
MH
ILL
_N H0
8\D
3\2 0D
2_
D3
.D W
G
XR
EF
S:
D0
\X
G-
BO
RD
ER
.D W
G;
D0
\X D-
NE
W
-S
TP
-S
CN
-0 2.D
W G;
D0
\X
D-
NE
W -S
TP
-S
CN
-0
3.D W
G;
CHEM.
FEED
TANK
| 01G001 |
| 01G002 |
| 01G003 |
| 01C001 |
| 01N001 |
| 01N002 |
| 01S001 |
| 01S002 |
| 01S003 |
| 01D001 |
| 01E001 |
| 01E002 |
| 01G060 |
| 01G065 |
| 01G074 |
| 06C100 |
| 06C101 |
| 06C401 |
| 06C501 |
| 06E100 |
| 06E401 |
| 07C100 |
| 07S14C |
| 07D130 |
| 07D301 |
| 07D302 |
| 09N001 |
| 09N002 |
| 09N003 |
| 09N004 |
| 09N005 |
| 09N006 |
| 09N007 |
| 09N008 |
| 09N009 |
| 09N010 |
| 10S130 |
| 10D130 |
| 10E130 |
| 20S130 |
| 20S14C |
| 20D130 |
| 20D140 |
| 20D301 |
| 20D302 |
| 20E130 |
| 20E14C |
| 20E701 |
| 20E702 |
| 20E703 |
| 20E704 |
| 20E705 |
File details come from the government source that posted it. Updated .