This document is a detailed naval engineering design drawing for a Great Lakes Research Vessel, specifically the Main Deck Plan and Vents and Sounds Schedule. The drawing, created by the Marine Design Center for Patti Shipyard Inc., provides comprehensive technical specifications for vessel systems including sea chest arrangements, tank vents, piping details, and deck layout. The main deck includes designated spaces such as a head, table/locker area, sorting tables, wet and dry labs, machine spaces, freezers, and various storage and technical areas. The drawing includes precise technical details like vent pipe specifications, strainer plate calculations, and compliance notes referencing U.S. Coast Guard (USCG) and American Bureau of Shipping (ABS) rules and regulations. The document is marked as Solicitation No. DACW61-98-R-0007 and was issued as a "Rev. 0" on 8-26-99, indicating it is a final design specification for a research vessel construction or modification project.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
DATE
REVISIONS
SYM.
DESCRIPTION
APPROVED
E
D
C
B
A
REV.
SHEET
589-D670-01
DWG. NO.
3/8" = 1'-0"
MARINE DESIGN CENTER
(MDC HULL 589)
CORPS OF ENGINEERS
DEPARTMENT OF THE ARMY
SOLICITATION NO.
N. STONE
DWG. NO.
CHECKED BY:
DACW61-98-R-0007
F
SCALE:
SIZE
T. CARVER
1-11-99
APPROVED BY:
DATE:
DRAWN BY:
DATE:
APPROVED:
MARINE DESIGN CENTER
PATTI SHIPYARD INC.
PROJECT NO.
NO.
REFERENCES
TITLE DWG. NO.
GREAT LAKES RESEARCH VESSEL
45678
F
MAIN DECK PLAN
E
D
C
B
A
50 49 4748 46 4445 43 4142 40 3839 37 3536 34 27303233 31 29 28 2426 25 23 2122 20 1819 17 1516 14 1213 11 10 9 8 67 45 3 12 0
HEAD
TABLE/LOCKER
SPACE
TABLE
SORTING
TABLE
LIFTER
LIFTER
(ELECTRONICS ROOM)
DRY LAB
MACHINE
ICE
FREEZER
LIVE
WELL
TABLE
SORTING
WET LAB
D N
PANTRY
LINE/CHAIN
LOCKER
(BELOW)
OPEN
CABLE PORT BHD
PENETRATION ABV.
AIR INTAKE STACK
ENGINE EXHAUST/
(BELOW)
OPEN
UP
VENTS, SOUNDS AND
SEA CHEST
FR
EE
ZE
R
R
EF
R
IG
TABLE
STORAGE
BLACK WATER SUMP
AFT VOID (P/S)
FORWARD VOID (P/S)
BALLAST No. 2 (P/S)
LAZZARETTE
NET STORAGE COMPARTMENT
BALLAST No. 1 (P/S)
DETAIL 6-A
SCALE: 1 1/2" = 1'-0"
LOCAL TANK PENETRATION VENT DETAILS
MAIN DECK
BOTTOM SHELL
MAIN DECK
6"x6"x1/4"
STRIKER PLATE
1" MIN.
2" MAX.
DETAIL 7-A
STRIPPING OR FILLING CONNECTION
SCALE: 1 1/2" = 1'-0"SCALE: 1 1/2" = 1'-0"
TYPICAL SOUNDING TUBE
DETAIL 8-A
COUPLING
BRASS CAP
MAIN DECK
SOUNDING TUBE
DECK CONNECTOR
(FLUSH w/DECK)
M
IN
DETAIL 5-A
SCALE: 1 1/2" = 1'-0"
REMOTE PENETRATION VENT DETAILS
M
IN
5/16" DOUBLER PLATE
MAIN DECK
SWLDG COUPLING
BULBOUS BOW
POTABLE WATER (P/S)
HYDRAULIC OIL
FUEL OIL (P/S)
OILY WATER
WASTE OIL
LUBE OIL
ALL PIPING MATERIALS AND WORKMANSHIP TO BE IN ACCORDANCE WITH
USCG AND ABS RULES AND REGULATIONS.
SUCH AS GRABRODS, STEPPING POINTS, AND HANDRAILS.
ALL NECESSARY UNIONS, FLANGES, FITTINGS, ETC., SHALL BE PROVIDED
TO COMPLETE INSTALLATION IF NOT SHOWN OR LISTED.
TO MECHANICAL INJURY AND TO PRECLUDE ITS USE FOR OTHER PURPOSES
ALL PIPING FOR VENTS AND SOUNDS SHALL BE SCH. 80.
PIPING SHALL BE ARRANGED SO THAT IT WILL NOT NORMALLY BE SUBJECT
S.S. FLAME SCREEN
S.S. FLAME SCREEN
S.S. FLAME SCREEN
S.S. FLAME SCREEN
S.S. FLAME SCREEN
16 MESH S.S. INSECT SCREEN
3"
1 1/2"
2"
2"
2"
2"
4"
2 1/2"
2"
2"
2"
2"
3"
3"
GENERAL NOTES
2.)
4.)
3.)
1.)
1 1/2"
1 1/2"
1 1/2"
1 1/2"
LUBE OIL, DIRTY OIL, & OILY BILGE
DOORS, WINDOWS, HATCHES, & MANHOLES
HULL OUTFIT & FITTINGS
BILGE AND BALLAST SYSTEM
FUEL OIL SYSTEM
POTABLE WATER
SANITARY AND SEWAGE SYSTEM
589-D660-01 589-D630-01 589-D665-01 589-D667-01 589-D635-01 589-D410-01 589-D420-01
WASTE OIL
AFT FUEL OIL
AFT FUEL OIL
WATER
OILY
LUBE OIL
OIL
HYDRAULIC
BALLAST No. 2
BALLAST No.1
BALLAST No.1
BALLAST No. 2
3" BALLAST TANK VENT (P/S)
SEE DETAIL 6-A
2" LAZZARETTE VENT
SEE DETAIL 5-A
1 1/2" BALLAST TANK S.T.
SEE DETAIL 8-A
2" NET STORAGE COMPARTMENT VENT
SEE DETAIL 6-A
1 1/2" BALLAST TANK S.T. (P/S)
SEE DETAIL 8-A
3" BALLAST TANK VENT (P/S)
SEE DETAIL 6-A
4" FUEL OIL TANK VENT (P/S)
4'-4" VENT HEIGHT, SEE DETAIL 6-A
2 1/2" POTABLE WATER TANK
VENT, SEE DETAIL 5-A
2" POTABLE WATER TANK
FILL, SEE DETAIL 7-A
2" AFT VOID VENT (P/S)
SEE DETAIL 6-A
2" FWD VOID VENT (P/S)
SEE DETAIL 5-A
1 1/2" AFT VOID S.T. (P/S)
SEE DETAIL 8-A
3" FUEL OIL FILLS
SEE DETAIL 7-A
2 1/2" BLACK WATER SUMP
TANK VENT, SEE DETAIL 5-A
2" WASTE WATER TANKS
STRIPPING CONNECTION
SEE DETAIL 7-A
1 1/2" FWD VOID S.T. (P/S)
SEE DETAIL 8-A
2" LINE/CHAIN LOCKER VENT
W/ 1 1/2" BULBOUS BOW
VENT BELOW (LOCATE AS
HIGH AS POSSIBLE)
1" ENGINE COOLER RECESS
VENT (P/S), SEE DETAIL 4-A
2" WASTE OIL STRIPPING CONNECTION
SEE DETAIL 7-A
2" HYDRAULIC OIL FILL
SEE DETAIL 7-A
2" OILY WATER STRIPPING CONNECTION
SEE DETAIL 7-A
2" LUBE OIL FILL
SEE DETAIL 7-A
2" WASTE OIL VENT
3'-0" VENT HEIGHT, SEE DETAIL 5-A
2" HYD. OIL VENT
3'-0" VENT HEIGHT, SEE DETAIL 6-A
2" OILY WATER VENT
3'-0" VENT HEIGHT ,SEE DETAIL 6-A
2" LUBE OIL TANK VENT
3'-0" VENT HEIGHT, SEE DETAIL 5-A
SEA CHEST ARRANGEMENT
DETAIL 4-C
VESSEL
LC
1" SEA CHEST VENT
SEE DETAIL 4-A
FLOOR LEVEL
SEA CHEST DETAILS (LKG AFT)
SCALE: 1 1/2" = 1'-0"
SEA CHEST STRAINER PLATE DETAILS
SCALE: 3" = 1'-0"
DETAIL 3-C
SEA CHEST DOUBLER PL. DETAILS
SCALE: 3" = 1'-0"
DETAIL 1-B
1'-2"
5/16" BOTTOM
SHELL PLATE
2'-0" O.D. x 3/8" DOUBLER
PLATE, SEE DETAIL 1-B
1/2" S.S. BOLT, NUT, & WASHERS
(TACK WELD NUT TO DOUBLER PL.)
BASELINE
3/8" STRAINER PLATE
SEE DETAIL 3-C
3/8" PLATE
13 1/2" O.D.
12"∅ SCH. 80 PIPE
3/4"∅ SCH. 80 SEA
CHEST BLOW-DOWN
LINE, SEE REF. 9
COMPRESSED AIR SYSTEM 589-D690-018
2" VENT PIPE
(UP TO MAIN DECK)
12"∅ SCH. 80
PIPE SEA CHEST
DRILL (4) 9/16"∅ HOLES
ON 9 1/2"∅ BOLT CIRCLE
DRILL (4) 9/16"∅ HOLES
ON 9 1/2"∅ BOLT CIRCLE
10 1/2" O.D. 3/8" PL.
1/2" TYP.
1/2" TYP.
1/2"
9" 8" 7" 5"
STRAINER PLATE SLOTS
TO BE ORIENTED
LONGITUDINALLY
CLEAR AREA REQUIRED IS TO BE 1.5 TIMES THE
(1997 ABS RULES FOR STEEL VESSELS UNDER 90 METERS)
SUCTION PIPE = 2 1/2" SCH. 80 PIPE
A =
STRAINER PLATE AREA CALCULATION
A = A x 1.5
THE CLEAR AREA OF THE SUCTION PIPE
4.24 in
STRAINER PIPE
PIPE
STRAINER REQ'DA = 4.24 in x 1.52
6.35 inSTRAINER REQ'DA = 2
29.0 in=A STRAINER OFF'D
1 1/2"
M
IN
VERTICAL VENT CHECK
WAGER MDL# 1500WSG
VERTICAL VENT CHECK
WAGER MDL# 1500WSG
2627 25
12" SCH. 80 PIPE
SEA CHEST SEE DETAIL 4-C
2 1/2" BILGE/BALLAST PUMP
SUCTION, SEE REF. 1
1'-0"
SCALE: 3/4" = 1'-0"
18 MESH S.S. INSECT SCREEN
18 MESH S.S. INSECT SCREEN
18 MESH S.S. INSECT SCREEN
18 MESH S.S. INSECT SCREEN
18 MESH S.S. INSECT SCREEN
18 MESH S.S. INSECT SCREEN
18 MESH S.S. INSECT SCREEN
SONAR TRUNK
FOREPEAK BALLAST TANK S.T.
SEE DETAIL 8-A
10" I.D.
1 1/2"1"
BLACK WATER
HOLD (BELOW)
HOLD (BELOW)
GREY WATER
TANK (BELOW)
AUX. FRESH WATER
TANK (BELOW)
AUX. FRESH WATER
1 1/2" FUEL OIL TANK S.T. (P/S)
SEE DETAIL 8-A
2 1/2" GREY WATER SUMP
TANK VENT, SEE DETAIL 5-A
2 1/2" AUX. FRESH WATER TANK
VENT (P/S), SEE DETAIL 5-A
2 1/2" GREY WATER HOLD
TANK VENT, SEE DETAIL 5-A
2 1/2" SEWAGE HOLD VENT
SEE DETAIL 5-A
18 MESH S.S. INSECT SCREEN3"GREY WATER SUMP --
18 MESH S.S. INSECT SCREEN2 1/2"GREY WATER HOLD --
18 MESH S.S. INSECT SCREEN2 1/2"BLACK WATER HOLD --
589-D610-01SHAFTING ARRANGEMENT & DETAILS9
M
IN
DETAIL 4-A
SCALE: 1 1/2" = 1'-0"
LOCAL TANK PENETRATION VENT DETAILS
MAIN DECK
DETAIL 3-A
SCALE: 1 1/2" = 1'-0"
REMOTE PENETRATION VENT DETAILS
M
IN
5/16" DBL. PL.
SCREEN
MAIN DECK
SWLDG COUPLING
SCREEN
3" FOREPEAK BALLAST TANK
VENT TO UPPER DECK
1" STERN TUBE VENT(P/S)
VENT, SEE DETAIL 4-A18 MESH S.S. INSECT SCREEN
SCREEN TYPE
VENTS AND SOUNDS SCHEDULE
TANK
FOREPEAK BALLAST
SIZE
3"
VENTS SOUNDING TUBES
1 1/2"
SIZE
QTY.
AUX. FRESH WATER (P/S) 2 1/2" 18 MESH S.S. INSECT SCREEN - -
SEA CHEST 2" NONE - -
ENGINE COOLER RECESS (P/S) 1" NONE - -
STERN TUBE (P/S) 1" NONE - -
2" FRESH WATER TANK
FILL (P/S), SEE DETAIL 7-A
2" BRONZE GATE VALVE
w/CAST STEEL TRIM
3/8" PLATE
24" O.D.
SEE REFERENCES BELOW FOR VENT PIPE MATERIAL SPECIFICATIONS5.)
0 AS BUILT; ISSUED AS 'REV. 0' 8-26-99
FOR EACH SPECIFIC PIPING SYSTEM.
NONE
LINE/CHAIN LOCKER 2" NONE - -
F. PATTI
2" FWD STORAGE
ROOM VENT
2" FWD MACHINERY
SPACE VENT