This document is a technical drawing for a ventilation modification plan for the R/V Kiyi, a research vessel operated by the US Geological Survey. The drawing details specific ventilation improvements, including the installation of a new 120 VAC axial fan with 115 CFM capacity and modifications to existing ventilation systems. The technical specifications include precise measurements, welding requirements, and material specifications, with notes specifying that all components must conform to ABS (American Bureau of Shipping) rules for marine vessel construction. The modifications involve changes to vents, sea chest areas, and piping, with detailed diagrams showing installation methods for the new ventilation components on the vessel's main deck and around ballast tank areas.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REVISIONS
GENERAL NOTES
REFERENCES
REV DESCRIPTION DATE APPROVED
REF DESCRIPTION DRAWING REV
VENTILATION MODIFICATION PLAN
ABV LKG DOWN
SCALE: 1/4" = 1'-0"
REVISION: SHEET:DRAWING NO:
CHECKED BY: REVIEWED BY:DRAWN BY:
SCALE: DATE:SIZE:
1 VENTS, SOUNDS AND SEA CHEST 589-D670-01 0
R/V KIYI, MDC HULL 589
106'-7" X 27' X 11'-10 3/4"
US GEOLOGICAL SURVEY
ASHLAND, WI
VENTILATION MODIFICATION
A
B
C
A
B
C
70 Essex St.
Mystic, CT 06355 voice 860.536.0009 fax 860.536.9117 jms@jmsnet.com
THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF JMS AND IS FURNISHED ON A CONFIDENTIAL BASIS.
THE RECIPIENT OF THE INFORMATION CONTAINED HEREIN MAY NOT DISCLOSE OR MAKE AVAILABLE THE SAME TO ANY OTHER PERSON OR BUSINESS FIRM, NOR MAY THE SAME BE USED EXCEPT FOR THE SPECIFIC PURPOSE INTENDED. JMS SHALL NOT BE HELD RESPONSIBLE FOR ANY UNAUTHORIZED
CHANGES TO THIS DOCUMENT OR ITS INTENT.
1 2 3 4
LML
AS NOTED
25-102-510 - SHEET 1 0F 1
05/21/2025
-DJF
ANSI B
1 2 3 4
EXISTING 3" BALLAST TANK VENT (P/S)
SEE REF 1
BALLAST NO. 2
BALLAST
NO. 2
EXISTING 2" NET STORAGE
COMPARTMENT VENT
SEE REF 1
EXISTING 3" BALLAST TANK VENT (P/S)
SEE REF 1
EXISTING 2" LAZZARETTE VENT
SEE REF 1
50 49 48 47 46 45 44 43 42
NEW 2" NET STORAGE
COMPARTMENT VENT
SEE DETAIL 3-A
NEW 120 VAC AXIAL
FAN, 115 CFM
SEE DETAIL 3-C
NEW 120 VAC AXIAL
FAN, 115 CFM
SEE DETAIL 3-C
NEW 2" LAZZARETTE VENT
SEE DETAIL 3-A
CL
1. ALL DIMENSIONS AND MEASUREMENTS TO BE CONFIRMED PRIOR TO
INSTALLATION.
2. ALL WELDING AND WELD SIZING TO BE I.A.W. ABS RULES FOR BUILDING AND
CLASSING MARINE VESSELS
3. ALL WORKMANSHIP, MATERIALS AND COMPONENTS TO CONFORM TO ABS
REQUIREMENTS. ALL STEEL TO BE ABS GRADE A. PLATE UNDER 1/2" THICK
MAY BE ASTM A-36 INSPECTED ACCORDING TO ABS RULES FOR MARINE
VESSEL CONSTRUCTION.
4. VENTILATION FAN TO BE INSTALLED FOR INTAKE OPERATION, DRAWING AIR
INTO THE SPACE. ENSURE FAN ORIENTATION AND WIRING SUPPORT AIRFLOW
DIRECTION AS SPECIFIED.
5. SHIPYARD TO CONFIRM VENTILATION FAN MOUNTING SPECIFICATIONS,
INCLUDING HOLE SIZE AND SPACING, WITH MANUFACTURER PRIOR TO
INSTALLATION.
6. PIPE TO BE SCH 80, ASTM A53 GR B.
7. PLATE TO BE A36 OR EQUAL.
DETAIL 3-A
OTBD LKG INBD
PORT SIDE SHOWN STBD SIDE SIMILAR
SCALE: 1" = 1'-0"
DETAIL 3-C
INBD LKG OTBD
SCALE: 3" = 1'-0"
SWLDG COUPLING
ASTM A234 GR WPB
MAIN DECK
2" SCH 80 PIPE
SEE NOTE 6
VERTICAL VENT CHECK
ABS TYPE APPROVED
WAGER MDL# 1500-1
OR EQUAL, THREADED
30" MIN
WT BHD
SWLDG COUPLING
ASTM A234 GR WPB
2" SCH 80 PIPE
NEW 120 VAC
AXIAL FAN
115 CFM
1" X 1/4" FLANGE
WELDED TO END OF PIPE
5" SCH 40 PIPE
1/4" THICK PIPE CAP WITH
HOLD CUT IN CENTER TO
FIT AND WELD VENT PIPE
SEE NOTE 7
STUD WELDED TO
FLANGE ON PIPE
FOR MOUNTING FAN
(4 PLACES)
SHIPYARD TO
CONFIRM STUD SIZE
WITH FAN MOUNTING
HOLE SIZE
SHIPYARD TO
PROVIDE MOUNTING
HARDWARE FOR
MOUNTING FAN
3/16 3/16
3/16 (3/16)
(3/16) 3/16
9"
3/16 3/16
3/16
TYP