Attachment_10_25-102-510-R-_Ventilation_Modifications_0002.pdf

PDF 219 KB Posted

Attached to
HAULOUT OF THE R/V KIYI
Solicitation number
140G0225R0017
Issued by

About this file

This document is a technical drawing for a ventilation modification plan for the R/V Kiyi, a research vessel operated by the US Geological Survey. The drawing details specific ventilation improvements, including the installation of a new 120 VAC axial fan with 115 CFM capacity and modifications to existing ventilation systems. The technical specifications include precise measurements, welding requirements, and material specifications, with notes specifying that all components must conform to ABS (American Bureau of Shipping) rules for marine vessel construction. The modifications involve changes to vents, sea chest areas, and piping, with detailed diagrams showing installation methods for the new ventilation components on the vessel's main deck and around ballast tank areas.

View the file

Other files

File Type Posted
Sol_140G0225R0017_Amd_0006.pdf PDF
Attachment_16_20-127-03-R1__KIYI__Stability_Report_126135316_126153827_0005.pdf PDF
Attachment_17_KIYI_Stability_Letter_126152428_0005.pdf PDF
Sol_140G0225R0017_Amd_0005.pdf PDF
Attachment_18_D105-01-1-_Lines_and_Offsets_0005.pdf PDF
Sol_140G0225R0017_Amd_0004.pdf PDF
Sol_140G0225R0017_Amd_0003.pdf PDF
Attachment_4a_25-102-238-R-_Emergency_Helm_Pump_Installation_0002.pdf PDF
Attachment_6_D589-660-01-1_Bilge-Ballast_System_0002.pdf PDF
Attachment_12_25-102-445-R-_Starlink_Antenna_Mounting_Modification_0002.pdf PDF
Attachment_2_589-D610-01-1-_Shafting_Arrangement___Details_0002.pdf PDF
Sol_140G0225R0017_Amd_0002.pdf PDF
Attachment_11_589-D645-01-1-_Fresh_Water_System_0002.pdf PDF
Attachment_14_18-139-260_Keel_Cooler_Modifications_0002.pdf PDF
Attachment_13_589-D640-01-1-Engine___Generator_Cooling_0002.pdf PDF
Attachment_3_589-D610-02-1-_Bow_Thruster_Details_0002.pdf PDF
Attachment_15_SFLC-Std-Spec-0740-(2020)_0002.pdf PDF
Attachment_8_589-D410-01-1-_Hull_Outfit_and_Fittings_0002.pdf PDF
Attachment_7_25-102-870-R-_Davit_Modification_0002.pdf PDF
Attachment_4_598-D615-01-1-_Steering_Arrangement_and_Details_0002.pdf PDF
Attachment_1_589-D501-01-1-_Sonar_and_Transducer_Well_Details_0002.pdf PDF
Attachment_5_25-102-225-R-_Shaft_Seal_Modifications_0002.pdf PDF
Attachment_9_589-D670-01-1-_Vents_Sounds_and_Sea_Chest_0002.pdf PDF
B08_Attachment_C_Schedule_of_Work_Items_Rev1_0001.docx DOCX document
Sol_140G0225R0017_Amd_0001.pdf PDF
Attachment_A_KIYI_Haulout_Specification_2025.pdf PDF
Attachment_C_Schedule_of_Work_Items.docx DOCX document
Attachment_B_PWS_KIYI_Shipyard_2025.pdf PDF
Sol_140G0225R0017.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REVISIONS

GENERAL NOTES

REFERENCES

REV DESCRIPTION DATE APPROVED

REF DESCRIPTION DRAWING REV

VENTILATION MODIFICATION PLAN

ABV LKG DOWN

SCALE: 1/4" = 1'-0"

REVISION: SHEET:DRAWING NO:

CHECKED BY: REVIEWED BY:DRAWN BY:

SCALE: DATE:SIZE:

1 VENTS, SOUNDS AND SEA CHEST 589-D670-01 0

R/V KIYI, MDC HULL 589

106'-7" X 27' X 11'-10 3/4"

US GEOLOGICAL SURVEY

ASHLAND, WI

VENTILATION MODIFICATION

A

B

C

A

B

C

70 Essex St.

Mystic, CT 06355 voice 860.536.0009 fax 860.536.9117 jms@jmsnet.com

THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF JMS AND IS FURNISHED ON A CONFIDENTIAL BASIS.

THE RECIPIENT OF THE INFORMATION CONTAINED HEREIN MAY NOT DISCLOSE OR MAKE AVAILABLE THE SAME TO ANY OTHER PERSON OR BUSINESS FIRM, NOR MAY THE SAME BE USED EXCEPT FOR THE SPECIFIC PURPOSE INTENDED. JMS SHALL NOT BE HELD RESPONSIBLE FOR ANY UNAUTHORIZED

CHANGES TO THIS DOCUMENT OR ITS INTENT.

1 2 3 4

LML

AS NOTED

25-102-510 - SHEET 1 0F 1

05/21/2025

-DJF

ANSI B

1 2 3 4

EXISTING 3" BALLAST TANK VENT (P/S)

SEE REF 1

BALLAST NO. 2

BALLAST

NO. 2

EXISTING 2" NET STORAGE

COMPARTMENT VENT

SEE REF 1

EXISTING 3" BALLAST TANK VENT (P/S)

SEE REF 1

EXISTING 2" LAZZARETTE VENT

SEE REF 1

50 49 48 47 46 45 44 43 42

NEW 2" NET STORAGE

COMPARTMENT VENT

SEE DETAIL 3-A

NEW 120 VAC AXIAL

FAN, 115 CFM

SEE DETAIL 3-C

NEW 120 VAC AXIAL

FAN, 115 CFM

SEE DETAIL 3-C

NEW 2" LAZZARETTE VENT

SEE DETAIL 3-A

CL

1. ALL DIMENSIONS AND MEASUREMENTS TO BE CONFIRMED PRIOR TO

INSTALLATION.

2. ALL WELDING AND WELD SIZING TO BE I.A.W. ABS RULES FOR BUILDING AND

CLASSING MARINE VESSELS

3. ALL WORKMANSHIP, MATERIALS AND COMPONENTS TO CONFORM TO ABS

REQUIREMENTS. ALL STEEL TO BE ABS GRADE A. PLATE UNDER 1/2" THICK

MAY BE ASTM A-36 INSPECTED ACCORDING TO ABS RULES FOR MARINE

VESSEL CONSTRUCTION.

4. VENTILATION FAN TO BE INSTALLED FOR INTAKE OPERATION, DRAWING AIR

INTO THE SPACE. ENSURE FAN ORIENTATION AND WIRING SUPPORT AIRFLOW

DIRECTION AS SPECIFIED.

5. SHIPYARD TO CONFIRM VENTILATION FAN MOUNTING SPECIFICATIONS,

INCLUDING HOLE SIZE AND SPACING, WITH MANUFACTURER PRIOR TO

INSTALLATION.

6. PIPE TO BE SCH 80, ASTM A53 GR B.

7. PLATE TO BE A36 OR EQUAL.

DETAIL 3-A

OTBD LKG INBD

PORT SIDE SHOWN STBD SIDE SIMILAR

SCALE: 1" = 1'-0"

DETAIL 3-C

INBD LKG OTBD

SCALE: 3" = 1'-0"

SWLDG COUPLING

ASTM A234 GR WPB

MAIN DECK

2" SCH 80 PIPE

SEE NOTE 6

VERTICAL VENT CHECK

ABS TYPE APPROVED

WAGER MDL# 1500-1

OR EQUAL, THREADED

30" MIN

WT BHD

SWLDG COUPLING

ASTM A234 GR WPB

2" SCH 80 PIPE

NEW 120 VAC

AXIAL FAN

115 CFM

1" X 1/4" FLANGE

WELDED TO END OF PIPE

5" SCH 40 PIPE

1/4" THICK PIPE CAP WITH

HOLD CUT IN CENTER TO

FIT AND WELD VENT PIPE

SEE NOTE 7

STUD WELDED TO

FLANGE ON PIPE

FOR MOUNTING FAN

(4 PLACES)

SHIPYARD TO

CONFIRM STUD SIZE

WITH FAN MOUNTING

HOLE SIZE

SHIPYARD TO

PROVIDE MOUNTING

HARDWARE FOR

MOUNTING FAN

3/16 3/16

3/16 (3/16)

(3/16) 3/16

9"

3/16 3/16

3/16

TYP

Sheets and Views