This document provides details for a federal contract opportunity to design and install a saltwater system for Dry Dock 8 at Norfolk Naval Shipyard in Portsmouth, Virginia. The solicitation number is N40085-22-R-2598 and related drawings and specifications can be accessed through Notice IDs N40085-22-R-2598_Drawings and N40085-22-R-2598_Specifications. The opportunity type is a special notice and the Naval Facilities Engineering Command is the contracting agency. Offerors are required to review the drawings and specifications to understand the full scope of designing and installing the saltwater system for Dry Dock 8, which will support maintenance of the aircraft carrier CVN-78. No pricing, response dates or other procedural details are provided in this document.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

POWER

SURFACE MOUNTED DUPLEX CONVENIENCE RECEPTACLE. 20A,

120V. GFI DENOTES GROUND FAULT INTERRUPTER, AC DENOTES

ABOVE COUNTER, WPIU DENOTES WEATHER PROOF ENCLOSURE

AND C DENOTES CEILING MOUNT (FLUSH).

SURFACE MOUNTED QUAD CONVENIENCE RECEPTACLE. 20A, 120V.

GFI DENOTES GROUND FAULT INTERRUPTER, AC DENOTES ABOVE

COUNTER, WPIU DENOTES WEATHER PROOF ENCLOSURE AND C

DENOTES CEILING MOUNT (FLUSH).

MOTOR RATED SWITCH OR MANUAL MOTOR STARTER WITH

OVERLOADS. M

M MOTOR / EQUIPMENT CONNECTION

HOMERUN TO PANEL. PANEL & CIRCUIT DESIGNATIONS AS

INDICATED.

MOTOR CONTROL / SAFETY SWITCH. 600V, 30A, IN NEMA 1

ENCLOSURE, UON. CROSS INDICATES COMINATION STARTER /

DISCONNECT, SLASH INDICATES COMBINATION VFD / SAFETY

SWITCH.

480Y/277V PANELBOARD.

208Y/120V PANELBOARD.

BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. CONDUIT

LARGER THAN 1/2" & WIRE LARGER THAN #12 MUST BE INDICATED.

FUSE SIZE IF INDICATED

DS30/F30

AMPACITY

D = SAFETY SWITCH

DS = COMBINATION STARTER / SAFETY SWITCH

V = VFD

ENCLOSED CIRCUIT BREAKER.

GROUNDING BUS BAR, MOUNT 7'-0" AFF UON.

SPD SURGE PROTECTIVE DEVICE

M DIGITAL METER

LIGHTING

120/277V TOGGLE SWITCH. SINGLE POLE, SUBSCRIPTS (A - E) WHEN

USED, DENOTES FIXTURES CONTROLLED.

TOGGLE SWITCH. SUBSCRIPT "3" = 3 WAY, "4" = 4 WAY.43

LED LUMINAIRE

LED EMERGENCY LUMINAIRE. EMERGENCY BATTERY DRIVER, 1400

LUMENS MINIMUM FOR 90 MINUTES, UON (NOTE: ALL FIXTURES

NOTED ON PLAN WITH HATCH AND/OR LABELED WITH AN 'E' AFTER

THE FIXTURE TYPE INDICATES EMERGENCY)

'E' DENOTES EMERGENCY F1E

MOUNTING HEIGHT

MUST BE SAME AS CEILING UON.

LOWER CASE LETTER DENOTES SWITCH

'LEG'. THE SWITCH WITH THE SAME

LETTER OPERATES THIS FIXTURE.

LUMINAIRE TYPE

8'-0" a

GROUND ROD, SUBSCRIPT INDICATES TYPE.

T: TEST WELL; SEE 1-ES516/C1

AIR TERMINAL.

DOWN CONDUCTOR.

LIGHTING PROTECTION AND GROUNDING

ROOF MAIN CONDUCTOR.

GENERAL

KEYNOTE TAG - REFER TO SHEET KEYNOTES ON EACH SHEET?

ABBREVIATIONS

Ø PHASE

1/C ONE CONDUCTOR

A AMPERAGE OR AMPS

AFF ABOVE FINISHED FLOOR

ARF ABOVE RAISED FLOOR

AHU AIR HANDLING UNIT

BKR BREAKER

CONDUIT

CIRCUIT BREAKER

CIRCUIT

DRAWING

EACH

EMPTY CONDUIT

ELECTRICAL

ELECTRICAL METALLIC TUBING

ENCLOSURE

EQUIPMENT

ELECTRIC WATER COOLER

ELECTRIC WATER HEATER

EXISTING

EXPLOSION PROOF EQUIPMENT

FAN COIL UNIT

FEET

GOVERNMENT FURNISHED CONTRACTOR INSTALLED

GOVERNMENT FURNISHED EQUIPMENT

GOVERNMENT FURNISHED GOVERNMENT INSTALLED

GROUND FAULT INTERRUPTER

GROUND

HEIGHT

HIGH INTENSITY DISCHARGE

HORSEPOWER

COMPUTER DISTRIBUTION HUB

LIGHT EMITTING DIODE

LUMINAIRE

MAIN CIRCUIT BREAKER

MAIN DISTRIBUTION PANEL

MECHANICAL

MAIN LUGS ONLY

MOUNTED

MOUNTING HEIGHT

NATIONAL ELECTRICAL CODE

NON FUSIBLE

NOT IN CONTRACT

NIGHT LIGHT

NOT TO SCALE

OUTLET BASE INFEED

OCCUPANCY SENSOR

PANEL

PANELBOARD

POLYVINYL CHLORIDE CONDUIT

QUANTITY

RECEPTACLE

REQUIRED

RIGID GALVANIZED STEEL

ROOM

SHEET

SUBSTATION

SWITCHBOARD

TELEPHONE

TYPICAL

UNLESS OTHERWISE NOTED

UNINTERUPTABLE POWER SUPPLY

WIRE

WEATHERPROOF WHILE IN USE

WIREWAY (TROUGH)

IN SCHEDULES, ITEM NOT APPLICABLE

VARIABLE REFRIGERANT FLOW UNIT

BH BASEBOARD HEATER

C

CB

CKT

DWG

EA

EC

ELEC

EMT

ENCL

EQUIP

EWC

EWH

EXIST

EXP

FCU

FT

GFCI

GFE

GFGI

GFI

GND

HGT

HID

HP

HUB

LED

LTS

MCB

MDP

MECH

MLO

MTD

MTG HT

NEC

NF

NIC

NL

NTS

OBI

OC

PNL

PNLBD

PVC

QU

REC

REQ'D

RGS

RM

SHT

SUB

SWBD

T

TYP

UON

UPS

VRF

W

WPIU

WW

X

TRANSFORMERXFMR

VARIABLE FREQUENCY DRIVEVFD

PANEL LP1A

100A, 208Y/120V-30, 4W

FEEDS FROM PANEL MDP

DEVICE ID

DEVICE RATING

POWER SOURCE

SWITCHGEARSWGR

GROUND RING COUNTERPOISE.

PROGRAMMABLE LOGIC CONTROLLERPLC

PLC PROGRAMABLE LOGIC CONTROLLER

PANEL - CIRCUIT NUMBERPA-1,3,5

NORMALLY OPENN.O.

VOLTAGE OR VOLTSV

MEDIUM VOLTAGE CIRCUIT BREAKER

MEDIUM VOLTAGE DRAW OUT CIRCUIT BREAKER

CURRENT TRANSFORMER

TRANSFORMER

LOW VOLTAGE CIRCUIT BREAKER

XXX - Y

ONE LINE DIAGRAM WIRE SIZE TAG; SEE 1-EP501/B2

XXX: AMPERAGE RATING OF THE CONDUCTORS

Y: NUMBER OF CONDUCTORS

T

RADIO TRANSMITTERRT

FIRE ALARM CONTROL PANELFACP

CONTRACT LINE ITEMCLIN

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

Y S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

C

R e v it P ro je c ts

\D R

Y D

P -1

-E

-P S ra ke m p .r v t

/2

/2

:3

:3

P

M

2-E-001

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

LE

G

E N

D , A

B B

R E

V

IA

TI

O

N S

A N

D G

E N

E R

A L

N O

TE

S

RHS

12858021

JCC RAK

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL/TLH

1364315

N40085-22-R-2598

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

JAS

DSN

GENERAL NOTES

1. ALL 2-E-001 SYMBOLS, ABBREVIATIONS, AND NOTES APPLY ONLY TO ED, EG,

EL, AND EP SERIES SHEETS. FOR ALL SITE ELECTRICAL SYMBOLS,

ABBREVIATIONS, AND NOTES SEE 2-E-011 AND 2-E-012.

2. PROVIDE EQUIPMENT GROUND WIRE(S) WITH FEEDERS AND BRANCH

CIRCUITS.

3. PROVIDE WIRING PER NATIONAL ELECTRICAL CODE (NEC).

4. LABEL AND IDENTIFY ELECTRICAL EQUIPMENT.

5. IDENTIFY FEEDERS/CIRCUITS AT EACH END OF THE WIRE AND AT EVERY

SPLICE OR JUNCTION/PULL BOX.

6. PROVIDE NAMEPLATES ON THE EXTERIOR OF ELECTRICAL PANELS AND

ENCLOSURES AS FOLLOWS:

FOR SAFETY SWITCHES, MOTOR STARTERS & VFDs, INSCRIBE THE TOP

LINE WITH THE NAME/DESIGNATION OF EQUIPMENT BEING FED BY SAME.

7. PROVIDE TYPED DIRECTORIES FOR PANELS (NEW OR EXISTING).

INCLUDED IN THIS PROJECT.

8. INTERIOR WIRING SYSTEMS MUST BE CONCEALED WITH FLUSH MOUNTED

BOXES/DEVICES, UON.

9. DRAWINGS ARE BASED ON EXISTING BUILDING PLANS AND FIELD

INVESTIGATIONS. VISIT THE EXISTING BUILDING AND ACQUAINT

HIMSELF/HERSELF WITH THE EXISTING CONDITIONS. EXAMINE EXISTING

DRAWINGS TO AVOID CONFLICTS.

10. COORDINATE LOCATION AND POWER REQUIREMENTS OF ELECTRICAL

DEVICES WITH MECHANICAL, PLUMBING, ARCHITECTURAL AND FIRE

PROTECTION DRAWINGS.

11. ELECTRICAL DEVICES SHOWN BUT NOT CIRCUITED MUST REMAIN ON THEIR

EXISTING CIRCUIT.

12. PROVIDE ARC-FLASH LABELS ON ALL SWITCHBOARDS / SWITCHGEAR /

PANELS / SAFETY SWITCHES / MOTOR STARTS / VFDs PER UFC 3-560-01

AND NFPA 70E. SEE DETAIL PLATE ON SHEET 2-EP-501.

13. SINGLE PHASE (120/208V) BRANCH CIRCUITS MUST CONSIST OF 2 #12, #12 G

IN 1/2" C, UON. THREE PHASE BRANCH CIRCUITS CONSIST OF 3 #12, #12 G IN

1/2" C, UON.

14. REFER TO PLANS FOR CONDUCTOR SIZING. COMPLY WITH THE

FOLLOWING GUIDELINES FOR CONDUCTOR RUN LENGTHS:

20A,120V CIRCUITS LONGER THAN 100' - USE #10 AWG TO LIMIT VOLTAGE

DROP ON BRANCH CIRCUITS TO 3%

20A, 120V CIRCUITS LONGER THAN 150' - USE #8 AWG TO LIMIT VOLTAGE

DROP ON BRANCH CIRCUITS TO 3%

20A, 277V CIRCUITS LONGER THAN 150' - USE #10 AWG TO

LIMIT VOLTAGE DROP ON BRANCH CIRCUITS TO 3%

15. COORDINATE ELECTRICAL WORK WITH ARCHITECTURAL, MECHANICAL AND

FIRE PROTECTION WORK PRIOR TO FABRICATION AND INSTALLATION TO

PREVENT CONFLICTS. NOTIFY THE CONTRACTING OFFICER WHERE

CONFLICTS ARE DISCOVERED PRIOR TO CONSTRUCTION AND BEFORE

BEGINNING WORK IN THOSE AREAS. ALL CONFLICTS THAT ARISE DUE TO

LACK OF COORDINATION MUST BE RECTIFIED AT NO COST TO THE

GOVERNMENT.

16. SEE SECTION 26 05 48.00 10 SEISMIC PROTECTION FOR ELECTRICAL

EQUIPMENT FOR ALL SYSTEMS REQUIRING SEISMIC BRACING, AND

SEISMICALLY RATED EQUIPMENT.

17. SEE PHASE 1 ELECTRICAL DRAWINGS FOR ALL DETAILS NOT SHOWN IN

PHASE 2 ELECTRICAL DRAWINGS.

18. CLIN EQUIPMENT IS ONLY INDICATED ON 2-EP1** AND 2-EP2** SERIES

SHEETS.

CONSTRUCTION NOTES

1. PROVIDE WRITTEN REQUESTS TO THE CONTRACTING OFFICER A MINIMUM

OF 14 CALENDAR DAYS PRIOR TO ANY POWER OUTAGES.

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R C

O N

S

TR

U C

T

IO

N

/2 8/

IS

SU

ED

F

OR

B

ID

D E

P A

R T

M E

N T

O

F

T

H

A V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

C

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

L

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

R

I D

ELECTRICAL LEGEND-(EXTERIOR UNDERGROUND)

UNDERGROUND DUCTBANK, CONCRETE ENCASED UON. DESCRIPTION AS INDICATED

EXISTING UNDERGROUND DUCTBANK, CONCRETE ENCASED UON. DESCRIPTION AS INDICATED

REMOVE EXISTING UNDERGROUND DUCTBANK, CONCRETE ENCASED UON DESCRIPTION AS INDICATED

UNDERGROUND CONDUIT DESCRIPTION AS INDICATED

EXISTING UNDERGROUND CONDUIT DESCRIPTION AS INDICATED

SYMBOL REFERS TO DEPTH OF DUCTBANK SECTION. SEE DUCTBANK DETAILS

UNDERGROUND ELECTRICAL DISTRIBUTION CONCRETE ENCASED DUCTBANK SECTION LOOKING IN DIRECTION OF

ARROWS

SPARE DUCT (TYPICAL). DESCRIPTION PER CABLE AND CONDUIT SCHEDULES ON SHEET 1-ES603

HEAVY LINE INDICATES BOTTOM OF DUCT

EXISTING CABLE DESIGNATION WITHIN CIRCLE (TYPICAL) DESCRIPTION PER CABLE AND CONDUIT SCHEDULES

ON SHEET 1-ES603

OCCUPIED CONDUIT, UNIDENTIFIED EXISTING CABLE

CABLE DESIGNATION (TYPICAL)

DESCRIPTION PER CABLE AND CONDUIT SCHEDULES ON SHEET 1-ES603

GROUNDING CONDUCTOR

EXOTHERMIC CONNECTION

GROUND ROD

MANHOLE OR HANDHOLE AS NOTED

EQUIPMENT CODE CLEARANCE

EQUIPMENT MAINTENANCE/VENTILATION CLEARANCE

EQUIPMENT MAINTENANCE/VENTILATION AND EGRESS CLEARANCE

JUNCTION BOX

LIGHT POLE

SPEAKER

EQUIPMENT CONNECTION

MOTOR CONNECTION, HP INDICATED

GENERATOR AS NOTED

DISCONNECT SWITCH, 600V IN NEMA 4X ENCLOSURE UON

3P = NO. OF POLES, 60 = SWITCH RATING, 40 = FUSE RATING

(NF INDICATES NON-FUSIBLE)

MOTOR CONTROLLER BY DIVISION 21 CONTRACTOR

EQUIPMENT AS NOTED

ELECTRICAL PANELBOARD (208Y/120 VOLT)

ELECTRICAL PANELBOARD (480Y/277 VOLT)

REMOVE EXISTING EQUIPMENT INDICATED

LIMIT OF DEMOLITION

NEW TO EXISTING CONNECTION

LIGHTING FIXTURE TYPE

COPING WALL JUNCTION CHAMBER

L - LIGHTING

F

P - PUBLIC ADDRESS

2 S1

X N1

J

M

3P

ELECTRICAL LEGEND (ONE-LINE & RISER DIAGRAMS)

POWER TRANSFORMER

POTENTIAL TRANSFORMER

CONTROL POWER TRANSFORMER

SURGE ARRESTOR

FUSED SWITCH

SWITCH

TRANSFER SWITCH

MOLDED CASE CIRCUIT BREAKER

LOW VOLTAGE DRAW-OUT POWER CIRCUIT BREAKER

MEDIUM VOLTAGE POWER CIRCUIT BREAKER

POWER DRAW OUT CIRCUIT BREAKER

GROUNDED WYE CONNECTION

UNGROUNDED WYE CONNECTION

CURRENT TRANSFORMER - SINGLE RATIO AS SHOWN

SURGE PROTECTIVE DEVICE

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

CONTROL SWITCH

CABLE TERMINATIONS

GROUNDING ELECTRODE CONNECTION

CABLE OR BUS, TYPE AND CHARACTERISTICS AS INDICATED

EXISTING CABLE OR BUS, TYPE AND CHARACTERISTICS AS INDICATED

NEW TO EXISTING CABLE SPLICE OR TAP

HOMERUN TO PANELBOARD. NO. OF ARROWS INDICATE NO. OF CIRCUITS.

TICKMARKS INDICATE NO. OF AWG CONDUCTORS.

REMOVE CABLE OR BUS, TYPE AND CHARACTERISTICS AS INDICATED

RELAY AND ANSI CONTROL FUNCTION SYMBOL.

CONTACTS - NORMALLY OPEN

CONTACTS - NORMALLY CLOSED

FUSE

GROUND

PUSHBUTTON

WHD METER

ASTRONOMICAL TIME CLOCK

PT

CPT

CT

600/S

ABBREVIATIONS

ELECTRICAL LEGEND (MISCELLANEOUS)

KEYNOTE SYMBOL

SPD

PT

CS

1/C SINGLE CONDUCTOR

3/C THREE CONDUCTOR

A AMP/AMPERE

AC ALTERNATING CURRENT

AF AMPERE FRAME

AFF ABOVE FINISHED FLOOR

AIC AMPS INTERRUPTING CAPACITY

AMI ADVANCED METERING INFRASTRUCTURE

AS AIR SWITCH

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AWG AMERICAN WIRE GAGE

BFG BELOW FINISHED GRADE

BLDG. BUILDING

BOD BASIS OF DESIGN

BRKR BREAKER

C CONDUIT

CAP CAPSTAN

CB CIRCUIT BREAKER

CFM CUBIC FEET/MINUTE

CHP CRANE HOTEL POWER

CKT CIRCUIT

CLR CLEAR

CONT CONTINUOUS

CPT CURRENT POTENTIAL TRANSFORMER

CST COMMUNICATIONS SHORE TIE

CT CURRENT TRANSFORMER

CU COPPER

D DEPTH

DDC DIRECT DIGITAL CONTROL

DIST DISTRIBUTION

DPDT DOUBLE POLE DOUBLE THROW

ECB ENCLOSED CIRCUIT BREAKER

EDC ENVIRONMENTAL DISTRIBUTION CENTER

EMH ELECTRIC MANHOLE

EPR ETHYLENE PROPYLENE RUBBER

EQ EQUAL

EQUIP EQUIPMENT

EX,EXIST EXISTING

FA FIRE ALARM

FLA FULL LOAD AMPS

FO FIBER OPTIC CABLE

FPMT FUTURE PAD-MOUNTED TRANSFORMER

GFI/GFCI GROUND FAULT CURRENT INTERRUPTER

GND GROUND

GOVT GOVERNMENT

GS GAS SWITCH

H HEIGHT

HMI HUMAN MACHINE INTERFACE

HOA HAND-OFF-AUTOMATIC

HP HORSE POWER

HPS HIGH PRESSURE SODIUM

JBOX JUNCTION BOX

KAIC THOUSAND AMPERE INTERRUPTING CAPACITY

KCMIL/MCM THOUSAND CIRCULAR MILS

KV KILOVOLT

KVA KILOVOLT AMPERE

KW KILOWATT

L LENGTH, ANGLE

LAN LOCAL AREA NETWORK

LTS LIGHTS

LV LOW VOLTAGE

LVCB LOW VOLTAGE CONNECTION BOX

LVST LOW VOLTAGE SHORE TIE STATION

MCB MAIN CIRCUIT BREAKER

MAX MAXIMUM

MESG METAL ENCLOSED INTERRUPTER SWITCHGEAR

MH MANHOLE

MIN MINIMUM

MM MULTIMODE

MT MOUNT

MTG HT MOUNTING HEIGHT

MV MEDIUM VOLTAGE

MVA THOUSAND KILOVOLT VOLT AMPERES

N.C. NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NESC NATIONAL ELECTRICAL SAFETY CODE

NF NON FUSED

NNSY NORFOLK NAVAL SHIPYARD

N.O. NORMALLY OPEN

NO. NUMBER

NTS NOT TO SCALE

NU NAVFAC UTILITIES

O/C ON CENTER

OSP OUTSIDE PLANT

P POLE

PA PUBLIC ADDRESS

PLC PROGRAMMABLE LOGIC CONTROL

PMS PAD-MOUNTED SWITCH

PMT PAD-MOUNTED TRANSFORMER

PT POTENTIAL TRANSFORMER

PW PUMPWELL

PVC POLYVINYL CHLORIDE

REC RECEPTACLE

REOL REMOVABLE END OF LINE RESISTOR

REQ'D. REQUIRED

RSC RIGID STEEL CONDUIT

RTU REMOTE TERMINAL UNIT (SCADA)

SCADA SUPERVISORY CONTROL AND DATA AQUISITION

SCH SCHEDULE

SE SERVICE ENTRANCE

SER SERVICE ENTRANCE RATED (UL LISTED)

SM SINGLE-MODE

SMFO SINGLE MODE FIBER OPTIC

SPA SPACE, SPACING

SMH SIGNAL MANHOLE

SS STAINLESS STEEL

SUB SUBSTATION

T TRANSFORMER

TB TURTLEBACK

TOD TOP OF DUCTBANK ELEVATION

TOM TOP OF MANHOLE ELEVATION

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

UL UNDERWRITERS LABORATORIES

V VOLT, VOLTAGE

VAC VOLTS ALTERNATING CURRENT

VFI VACUUM FAULT INTERRUPTER

W WATT, WIRE, WIDTH

WI WEATHERPROOF IN-USE

WP WEATHERPROOF

XFMR TRANSFORMER

E

G

WHD

ATC

S

A

J

FEEDER DESIGNATION. SEE SCHEDULES

FIRE ALARM PULL BOX, 18" X 12" X 18"

J

GROUND TEST PIT

DZ RAD WAS

12858022

L E

G E

N D

A

B B

R E

V I A

T I O

M

B O

L S

2-E-011

AS NOTED

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

D

1. ALL 2-E-011 AND 2-E-012 SYMBOLS, ABBREVIATIONS AND NOTES APPLY ONLY TO ED AND ES

SERIES SHEETS.

2. CONDUIT AND DUCT ROUTINGS SHALL NOT INTERFERE WITH NEW OR EXISTING EQUIPMENT,

PIPING, OR CONDUIT AND SHALL NOT OBSTRUCT ACCESS TO ANY EQUIPMENT.

3. THE EQUIPMENT GROUND CONDUCTOR SHALL BE CONNECTED TO ALL DEVICES SUCH THAT

REMOVAL OF ANY DEVICE CANNOT INTERRUPT THE CONTINUITY OF THE EQUIPMENT

GROUNDING CONDUCTOR TO AND FROM OTHER DEVICES OR EQUIPMENT.

4. WIRE AND CONDUIT FOR EQUIPMENT AND MOTOR LOADS SHALL BE CONTINUOUS IN SIZE AND

COUNT FROM THE SOURCE TO THE FINAL CONNECTION. SIZE AND COUNT SHALL BE AS

INDICATED ON THE CIRCUIT HOMERUN OR FEEDER SCHEDULE, UNLESS OTHERWISE NOTED.

5. CONTRACTOR SHALL PERFORM A FEEDER, MANHOLE AND DUCT-ROUTE SURVEY PRIOR TO

BEGINNING CONSTRUCTION TO VERIFY THE ROUTING OF THE EXISTING FEEDERS,

AVAILABILITY OF EXISTING MANHOLES AND DUCTS INTENDED TO BE USED. PROVIDE THE

CONTRACTING OFFICER WITH RESULTS OF THIS SURVEY AND SKETCH OF DUCTBANK

SECTIONS SHOWING LOCATIONS OF OCCUPIED DUCTS AND CABLES TO BE INSTALLED.

6. THE CONTRACTOR SHALL DE-WATER MANHOLES AND HANDHOLES BEFORE COMMENCING

WORK. THE CONTRACTORS DE-WATERING PUMPS SHALL BE AVAILABLE IN CASE WATER

SEEPAGE DOES NOT SUBSIDE. UNDER NO CIRCUMSTANCES SHALL OPEN CABLE SPLICES OR

CUT TERMINATIONS EVER COME IN CONTACT WITH WATER.

7. UNLESS SPECIFICALLY NOTED TO BE EXISTING, ALL WORK AND MATERIAL SHALL BE

PROVIDED BY THE CONTRACTOR. WHEREVER AN EXISTING TO PROPOSED CONNECTION IS

REQUIRED, PROVIDE EXTENSION RINGS, SPLICES, WIRE, CONDUIT FITTINGS, AND

ASSOCIATED APPURTENANCES. PERFORM ALL CUTTING AND PATCHING AS REQUIRED TO

MAKE THE CONNECTIONS.

8. THE CONTRACTOR SHALL COORDINATE INSTALLATION OF ALL COMMUNICATIONS (NAVFAC

UTILITIES, SCADA, ETC.) CABLES AND EQUIPMENT INTO EXISTING FACILITIES AND BUILDINGS

WITH CONTRACTING OFFICER AND NNSY PRIOR TO COMMENCING THIS WORK.

COORDINATION AND DISCUSSION BETWEEN ALL PARTIES INVOLVED WITH THIS WORK SHALL

TAKE PLACE IN WEEKLY MEETING AND ADDITIONAL MEETINGS AS REQUIRED ESPECIALLY

FOR THIS PURPOSE.

9. THE CONTRACTOR SHALL CLOSELY STUDY THE CONSTRUCTION PLANS AND NOTES AS

OUTLINED. SLIGHT DEVIATIONS FROM CONFINED WORK SPACES MAY BE NECESSARY TO

FULLY COMPLETE A CONSTRUCTION AREA AS OUTLINED ON THOSE SHEETS. THE DEVIATIONS

SHALL BE HELD TO A MINIMUM AND SHALL BE FULLY COORDINATED WITH THE CONTRACTING

OFFICER. ALL SUCH DEVIATIONS SHALL BE MADE WITH NO ADDITIONAL COST TO THE

GOVERNMENT.

10. DURING THE EXECUTION OF THIS WORK, THE GOVERNMENT WILL CONTINUE TO OCCUPY AND

OPERATE ALL ADJACENT FACILITIES, PIERS, BERTHS, WHARFS, BUILDINGS AND UTILITIES,

AND, THEREFORE, WILL REQUIRE CONTINUOUS OPERATION OF ALL EXISTING ELECTRIC AND

TELECOMMUNICATIONS SERVICES. OUTAGES REQUIRED FOR CONSTRUCTION PURPOSES

SHALL BE SCHEDULED FOR THE SHORTEST PRACTICAL PERIODS OF TIME, AND THEN ONLY

BY PRE-ARRANGEMENT WITH THE CONTRACTING OFFICER FOR MUTUALLY AGREEABLE

PERIODS. AFTER EACH OF WHICH THE INTERRUPTION SHALL CEASE AND SERVICE SHALL BE

RESTORED.

11. THE CONTRACTOR SHALL PERFORM WORK ON UNENERGIZED CABLES WITH ENERGIZED

CABLES IN MANHOLE.

12. SPLICING OF FEEDERS WITHIN MANHOLES OR UNDERGROUND IS DISCOURAGED.

13. PLATFORM MOUNTED EQUIPMENT (SUBSTATIONS, MV SWITCVHES, SWITCHGEAR,

GENERATORS, FUEL STORAGE SYSTEMS, ETC.) LAYOUT IS PARTIALLY DIAGRAMMATIC.

CONTRACTOR SHALL VERIFY THE CODE REQUIRED CLEARANCES FOR APPROVED

EQUIPMENT AND ADJUST THE EQUIPMENT LAYOUT, DUCTBANK AND CONDUIT ROUTING, AND

SUPPORTING STRUCTURES AS NECESSARY.

1. COORDINATE ALL DUCTBANK ROUTING WITH EXISTING AND NEW STRUCTURES, INCLUDING

PLATFORM PILES. ROUTE DUCTBANKS TO AVOID CONFLICTS.

2. LOCATIONS AND ROUTING OF CONDUITS, DUCTBANKS AND ELECTRICAL STRUCTURES SHOWN

ON THE DRAWINGS ARE APPROXIMATE. PRIOR TO EXCAVATION AND INSTALLATION, THE

CONTRACTOR SHALL COORDINATE AND VERIFY LOCATIONS, ROUTING AND DEPTHS OF ALL

CONDUITS, DUCTS AND STRUCTURES WITH ALL OTHER TRADES TO AVOID CONFLICTS WITH ALL

NEW AND EXISTING UTILITIES AND STRUCTURAL FEATURES.

3. THE CONTRACTOR SHALL COORDINATE THE ROUTING OF THE DUCTBANKS AND MAKE ANY

ADJUSTMENTS REQUIRED IN HORIZONTAL AND VERTICAL DIRECTIONS OF THE ENTIRE

DUCTBANK RUN TO MISS ANY UTILITIES INCLUDING OTHER DUCTBANKS. THE ADJUSTMENTS

SHALL CONSIDER THE ENTIRE CABLING RUN SHALL NOT EXCEED 360 DEGREES WORTH OF

BENDS BETWEEN PULLING POINTS IN A SINGLE RUN PER THE NEC.

4. PROVIDE 20 MIL PLASTIC SHEETING IN BETWEEN DUCTBANKS WHERE DUCTBANKS COME IN

CONTACT.

5. PROVIDE PULL STRING IN EVERY DUCT WHERE EXISTING CABLING IS REMOVED PER

DEMOLITION DRAWINGS.

GENERAL DEMOLITION NOTES:

1. SEE DEMOLITION ONE-LINE DIAGRAMS AND CABLE SCHEDULES ON ES600 SERIES SHEETS.

2. REMOVE CONDUCTORS FROM CONDUITS AND DUCTS AND DISCONNECT FROM ALL POWER

SOURCES AS REQUIRED TO ACCOMPLISH THE WORK OF THIS CONTRACT. REFER TO SHEETS ED

SERIES DRAWINGS FOR DEMOLITION, INCLUDING UTILITIES, DUCTBANKS AND OTHER

STRUCTURES.

3. DEMOLITION OF DUCTBANKS SHALL INCLUDE REMOVAL OF SECTIONS INDICATED IN ED100

SERIES DRAWINGS. ALL MANHOLES ARE EXISTING TO REMAIN, UON.

4. EXCEPT AS NOTED ELSEWHERE AND AS REQUIRED BY CONSTRUCTION PHASING, ALL EXISTING

SERVICES (ELECTRIC, TELEPHONE, LAN, NAVFAC UTILITIES, CATV, PA, NAVFAC UTILITIES

SECURITY, ETC.) SHALL REMAIN ACTIVE.

5. THE ENTIRE RUN OF ABANDONED CONDUITS WITHIN DUCTBANKS SHALL BE GROUTED

COMPLETE. GROUT ABANDONED CONDUITS WITHIN DUCTBANKS FLUSH WITH THE INTERIOR OF

MANHOLES AND FLUSH WITH THE ENDS OF THE CONDUITS.

6. SEE ELECTRICAL GENERAL NOTES FOR ADDITIONAL DEMOLITION AND REDISTRIBUTION

REQUIREMENTS.

ELECTRICAL GENERAL NOTES (APPLICABLE TO ALL SHEETS)ELECTRICAL GENERAL DUCTBANK NOTES

GENERAL CONSTRUCTION NOTES:

1. THE CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING OFFICER FOR OTHER WORK

AROUND DRY DOCK 8.

2. SCHEDULE WORK AROUND ALL TEMPORARY AND PERMANENT EQUIPMENT ASSOCIATED WITH

THE GOVERNMENT WORK IN DRY DOCK 8.

3. ALL OUTAGES REQUIRED WILL BE SCHEDULED WITH THE GOVERNMENT AT LEAST 30 DAYS

PRIOR. THE CONTRACTOR SHALL WORK AROUND THE SCHEDULE OF THE GOVERNMENT WITHIN

DRY DOCK 8.

DZ RAD WAS

12858023

G E

N E

R A

L

N

O T

E S

2-E-012

EMH-584

EMH-583A

EMH-583

2 4 6

2 4 6

2 4 6

SUBSTATION Z15

SUBSTATION Z-1B3

2 4 6

BUILDING #271

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

D

SHEET NOTES

NORTH

PLAN

KEY PLAN

4 5

11 12

2 3

13 14

SHEET KEYNOTES

SCALE: 1" = 20'

PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 4

A1

PLAN

NORTH

40'10'0 20'

1. DISCONNECT FEEDER 30 FROM AIR SWITCH AS-5 INSIDE BUILDING

271.

2. REMOVE FEEDER 30 CONDUCTORS FROM DUCTBANK.

3. DISCONNECT FEEDER 28 FROM SUBSTATION Z-1B DISTRIBUTION

CIRCUIT BREAKER INSIDE BUILDING 271.

4. REMOVE FEEDERS 28 CONDUCTORS FROM DUCKBANK.

5. DISCONNECT FEEDER 29 FROM SUBSTATION Z1 DISTRIBUTION

CIRCUIT BREAKER INSIDE BUILDING 271.

6. REMOVED FEEDER 29 CONDUCTORS FROM DUCKBANK.

1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.

2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND

ABBREVIATIONS.

MATCH LINE

A1/2-ED129

DZ RAD WAS

12858024

E L

E C

T R

I C

T

E

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

2-ED124

EMH-877

TMH-1498

EMH-1499

EMH-1501

TMH-1-10

062306

062306

F1

23XX

230606

060606

060606

XX

XX

XX

X

X

XX 06

X

X

X

060606 06 0606 06 06

F1

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

D

SHEET NOTES

NORTH

PLAN

KEY PLAN

4 5

11 12

2 3

13 14

MATCH LINE

A1/2-ED132

M A

T C

H

L I N

E

A E

D

SCALE: 1" = 20'

PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 7

A1

PLAN

NORTH

40'10'0 20'

1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.

2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND

ABBREVIATIONS.

DZ RAD WAS

12858025

E L

E C

T R

I C

T

E

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

2-ED127

EMH-1501

TMH-1-11

EMH-N11

PRIMARY UNIT SUBSTATION

DD8-S/S-1N

MV SWITCH DD8-G/S-3N

REFER TO "ENLARGED PLAN - SUBSTATION

PLATFORM" ON SHEET 2-E-405

F1

060606

062315

062317

062306

X

X

060606

23XX

230606

060606

060606

XX

XX

XX

X

X

XX 06

X

X

X

060606 06 0606 06 06

F1

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

D

SHEET NOTES

NORTH

PLAN

KEY PLAN

4 5

11 12

2 3

13 14

MATCH LINE

A1/2-ED133

M A

T C

H

L I N

E

A E

D

M A

T C

H

L I N

E

A E

D

SCALE: 1" = 20'

PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 8

A1

PLAN

NORTH

40'10'0 20'

1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.

2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND

ABBREVIATIONS.

DZ RAD WAS

12858026

E L

E C

T R

I C

T

E

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

2-ED128

EMH-N12

MV SWITCH

DD8-G/S-2N

MV

SWITCH

DD8-G/S-1N

TMH-1-12

EMH-585

EMH-866

EMH-865

EMH-864

EMH-863

CAPSTAN 34

M18

EMH-862

EMH-861

1 2 1 2

BUILDING #273

X

X

X

X

X

060606

X

X

X

X

X

M5

X

X

C1

X

X

X

X

X

M5

X

X

C1

04 X

X

M6

X

X

C1

04 04

C1

M6

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

D

SHEET NOTES

NORTH

PLAN

KEY PLAN

4 5

11 12

2 3

13 14

SCALE: 1" = 20'

PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 9

A1

PLAN

NORTH

40'10'0 20'

1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.

2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND

ABBREVIATIONS.

MATCH LINE

A1/2-ED134

M A

T C

H

L I N

E

A E

D

M A

T C

H

L I N

E

A E

D

1. REMOVE POWER FEEDER M6 FROM EMH-860 TO A SPLICE WITH

FEEDERS M65 AND M18 INSIDE EMH-863. PROVIDE PULL WIRE IN

VACATED CONDUIT. PROTECT THE REMAINING FEEDERS M5 AND

M18 CONDUCTORS INSIDE EMH-863 FOR FUTURE RECONNECTION.

2. REMOVE SLUICE GATE CONTROL CABLE C1 BACK TO ITS SOURCE

IN BUILDING 273.

SHEET KEYNOTES

DZ RAD WAS

12858027

E L

E C

T R

I C

T

E

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

2-ED129

EMH-587

EMH-586

EMH-585

PAD

MOUNTED

TRANSFORMER

SHORE POWER

PEDESTAL

4 14

CRANE POWER

RECEPTACLE

6 7

6 7

2 6 7

SHORE POWER

PEDESTAL TB39-3

BUILDING #829

EMH-860 13

CAISSON POWER

PEDESTAL

P1

SLUICE GATE

VALVE

CAPSTAN 33

M8

C1

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

M7

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

D

NORTH

PLAN

KEY PLAN

4 5

11 12

2 3

13 14

MATCH LINE

A1/2-ED135

SHEET NOTES

SHEET KEYNOTES

SCALE: 1" = 20'

PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 10

A1

PLAN

NORTH

40'10'0 20'

1. REMOVE SERVICE LATERAL CONDUCTORS TO PUMP STATION SERVICE

ENTRANCE EQUIPMENT. REFER TO SHEET 2-GD160 FOR EQUIPMENT

LOCATION.

2. REMOVE FEEDER 30 CONDUCTORS FROM DUCTBANK.

3. REMOVE SWPS-2 SERVICE TRANSFORMER. TURN TRANSFORMER TO

THE GOVERNMENT.

4. DISCONNECT AND DEMOLISH SHORE POWER PEDESTAL TB39-5.

5. DISCONNECT AND DEMOLISH CRANE POWER RECEPTACLE AND

DISCONNECT.

6. REMOVE FEEDERS 28 CONDUCTORS FROM DUCTBANK.

7. REMOVE FEEDER 29 CONDUCTORS FROM DUCTBANK.

8. DISCONNECT SLUICE GATE VALVE POWER FEEDER M8 AND CONTROL

CABLE C1. REMOVE FEEDER M8 BACK TO A SPLICE INSIDE EMH-860.

9. DISCONNECT CAISSON POWER PEDESTAL FEEDER P1. REMOVE

CONDUCTORS BACK TO A SPLICE INSIDE EMH-860.

10. REMOVE CAPSTAN 33 FEEDER M7 BACK TO EMH-860. PROVIDE PULL

WIRE IN VACATED CONDUIT.

11. REMOVE POWER FEEDER M6 FROM EMH-860 TO A SPLICE WITH FEEDERS

M65 AND M18 INSIDE EMH-863. PROVIDE PULL WIRE IN VACATED

CONDUIT. PROTECT THE REMAINING FEEDERS M5 AND M18

CONDUCTORS INSIDE EMH-863 FOR FUTURE RECONNECTION.

12. REMOVE SLUICE GATE CONTROL CABLE C1 BACK TO ITS SOURCE IN

BUILDING 273.

13. FACILITATE PARTIAL DEMOLITION OF EMH860 AND CONNECTING

PATHWAYS. REFER TO SHEETS 2-SD110 AND 2-ES503 FOR ADDITIONAL

INFORMATION.

14. DISCONNECT TB39-5 TELEPHONE CABLE AND REMOVE IT BACK TO

TB39-3.

1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.

2. REFER TO SHEET 1-E011 FOR ELECTRICAL LEGEND AND

ABBREVIATIONS.

M A

T C

H

L I N

E

A E

D

DZ RAD WAS

12858028

E L

E C

T R

I C

T

E

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

2-ED130

EMH-631

EMH-S631

BUILDING 272

EMH-632

EMH-881

EMH-878

MV SWITCH G/S-4

MV SWITCH G/S-3

EMH-1490

MV SWITCH

DD8-G/S-1S

EMH-632S

TMH-1-09

EMH-1-09

MV SWITCH

DD8-G/S-1S

F2

F5 04

X

X

X

X

XXX

X0606

X0606

11 X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XXXX

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XXXX

F4

F3

X

X

XXX

X

X

X

X

XXX

X0606

X0606

F1

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XXXXX

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

D

NORTH

PLAN

KEY PLAN

4 5

11 12

2 3

13 14

M A

T C

H

L I N

E

A E

D

SHEET NOTES

SHEET KEYNOTES

1. DISCONNECT FEEDERS 32 FROM DISTRIBUTION VI 2.3KV BUS

INSIDE BUILDING 272.

2. REMOVE FEEDER 32 CONDUCTORS FROM DUCTBANK.

SCALE: 1" = 20'

PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 12

A1

PLAN

NORTH

40'10'0 20'

1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.

2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND

ABBREVIATIONS.

MATCH LINE

A1/2-ED127

DZ RAD WAS

12858029

E L

E C

T R

I C

T

E

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

2-ED132

14'

EMH-640S

BUILDING 274

EMH-885

EXISITNG

EMH-888

EMH-640

EMH-1487

UNIT

SUBSTATIONS

REFER TO "ENLARGED PLAN - SUBSTATION

PLATFORM" ON SHEET 2-E-406

EMH-1-08

EMH-1-08A

PRIMARY UNIT

SUBSTATION DD8-S/S-1S

MV SWITCH DD8-G/S-3S

TMH-1-08

F3

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XXX

F4

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XXXX

F4

200606 23

200606 23

200606 23

060606 06

06 06 06

20 06 06

20 06 06

20 06 06

200606 23

200606 23

200606 23

060606 06

X

X

X

X

XXX

X0606

X0606

X

X

X

X

XXX

X0606

X0606

X

X

X

X

XXX

X0606

X0606

F3

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

D

NORTH

PLAN

KEY PLAN

4 5

11 12

2 3

13 14

M A

T C

H

L I N

E

A E

D

M A

T C

H

L I N

E

A E

D

SHEET NOTES

SHEET KEYNOTES

SCALE: 1" = 20'

PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 13

A1

PLAN

NORTH

40'10'0 20'

1. REMOVE FEEDER 32 CONDUCTORS FROM DUCTBANK.

1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.

2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND

ABBREVIATIONS.

MATCH LINE

A1/2-ED128

DZ RAD WAS

12858030

E L

E C

T R

I C

T

E

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

2-ED133

EMH-634S

EMH-S635

EMH-635

EMH-S5

EMH-634

PUMPWELL

EMH-891

MV

SWITCH

DD8-G/S-2S

SUBSTATION Z4-E

SUBSTATION

Z4-F

EMH-892

EMH-890

EMH-893

EMH-1-07

EMH-895

EMH-896

TMH-1-07

200606 23

XX

XX

X

XX

XX

X

X

XX

XX

X XX

200606 23

200606 23

060606 06

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X X

F4

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XXX

F4

F4

2006 23

2006 23

2006 23

0606 06

X

X

X

X

X

X

X

X

X X

X X

X X

X X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XXX

X0606

X0606

XX

X X XX

X

X

X

X

X

X

X

X

X

X

X X XX

X

X

XX

X

X

X

X

45 06

38 46

39 47

T1

T2

F4

F4

T1

T2

GENERATOR

FUEL STORAGE

SWITCHGEAR

T1

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

D

KEY PLAN

4 5

11 12

2 3

13 14

MATCH LINE

A1/2-ED129

M A

T C

H

L I N

E

A E

D

M A

T C

H

L I N

E

A E

D

SHEET NOTES

SHEET KEYNOTES

SCALE: 1" = 20'

PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 14

A1

PLAN

NORTH

40'10'0 20'

1. REMOVE FEEDERS 32 CONDUCTORS FROM DUCTBANK.

1. REFER TO SHEET 1-ES603 FOR CABLE AND CONDUIT SCHEDULE.

2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND

ABBREVIATIONS.

DZ RAD WAS

12858031

E L

E C

T R

I C

T

E

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

2-ED134

T L

EMH-636

TMH-636S

MV SWITCH

EMH-913

EMH-898

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XX31

1 2

BUILDING #828

D E

P A

R T

M E

T

V

Y

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

DES DRW

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

DRAWFORM REVISION: 25 AUG 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N A

V A

L

S

T A

T I O

N

N

O R

F O

L K

V

A

N O

R F

O L

K

N

A V

I P

Y A

R D

P O

R T

S M

O U

T H

V

I R

G I N

I A

P

D

R Y

D O

C K

S A

LT

W

A

TE

R S

Y S

TE

M

FO

R

C V

N -7

JTL/TLH

EJA

DSN

1364315

N40085-22-R-2598

DLB

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

02/02/2022

I S

S U

D

SHEET NOTES

KEY PLAN

MATCH LINE

A1/2-ED130

SHEET KEYNOTES

4 5

11 12

2 3

13 14

SCALE: 1" = 20'

PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 15

A1

PLAN

NORTH

40'10'0 20'

1. REMOVE FEEDER 32 CONDUCTORS FROM DUCTBANK.

2. REMOVE FEEDER 31 CONDUCTORS FROM DUCTBANK

3. REMOVE DISCONNECT AND REMOVE MV SWITCH. TURN EQUIPMENT TO THE

GOVERNMENT.

4. REMOVE SERVICE FEEDER CONDUCTORS TO PUMP STATION SERVICE

ENTRANCE EQUIPMENT. REFER TO SHEET 2-GD160 FOR EQUIPMENT

LOCATION.

1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.

2. REFER TO SHEET 1-E011 FOR ELECTRICAL LEGEND AND

ABBREVIATIONS.

M A

T C

H

L I N

E

A E

D

DZ RAD WAS

12858032

E L

E C

T R

I C

T

E

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

2-ED135

T

T

PS6-GENERATOR

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

C

R e v it P ro je c ts

\D R

Y D

P -1

-E

-P S ra ke m p .r v t

/2

/2

:3

:3

P

M

2-EG151

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

P U

M P

S T

A T

IO

N

LI

G

H

TI

N

IN

G P

R O

T E

C

TI

O N

A N

D G

R O

U N

D

IN

G P

LA

N

RHS

12858033

JCC RAK

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL/TLH

1364315

N40085-22-R-2598

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

JAS

DSN

3/16" = 1'-0" A3

PUMP STATION 6 - LIGHTNING PROTECTION PLAN

SHEET NOTES

1. PROVIDE A FRANKLIN ROD TYPE LIGHTNING PROTECTION SYSTEM IN

ACCORDANCE WITH NFPA780, AND UL96A. THIS IS A PERFORMANCE

BASED SYSTEM, DESIGN AND INSTALLATION MUST FOLLOW APPLICABLE

STANDARDS AND SPECIFICATIONS.

2. ALL SYSTEM MATERIALS MUST BE UL LISTED FOR LIGHTNING

PROTECTION SYSTEMS. LABEL ALL CONDUCTORS EVERY 10' WITH UL

LISTING.

3. ENSURE THAT MATERIALS USED ARE COMPATIBLE WITH THE ROOFING

SYSTEM. PROVIDE COPPER CONDUCTORS. DO NOT USED DISSIMILAR

METALS.

4. SEE ARCHITECTURAL ROOF PLAN FOR PRICING AND DESIGN PURPOSES.

5. SEE SHEET 2-EG502 FOR LIGHTNING PROTECTION DETAILS.

6. ELECTRICAL DISTRIBUTION GROUNDING MUST COMPLY WITH NEC ART.

250.

7. BOND ALL METAL HARDWARE SUCH AS LADDERS, VENT PIPING, ETC. AND

TO COORDINATE WITH ALL EXISTING STRUCTURES.

8. PATCH AND REPAIR EXISTING PAVED AREAS.

9. COMPLY WITH FAA STD-19F.

0' 4' 8' 12'

PLAN

NORTH

PLAN

NORTH

KEY PLAN

PS-6

T

T

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R C

O N

S

TR

U C

T

IO

N

/2 8/

1" = 10'-0" (2-EL151)

PUMP STATION 6 - SITE EQUIPMENT GROUNDING PLAN

SHEET NOTES

1. PROVIDE GROUND CONNECTION TO PLATFORM REBAR AND FOUNDATION

PILE.

2. PROVIDE GROUND CONNECTION TO EQUIPMENT AND ENCLOSURE.

3. PROVIDE GROUND ROD TEST WELL; SEE1-ES516/C1.

4. PROVIDE GROUND CONNECTION TO PLATFORM HANDRAIL. IF HANDRAIL IS

NOT CONTINUOUS, BOND ALL NONCONTINOUS SECTIONS TOGETHER.

0" 10' 30'20'

PLAN

NORTH

IS

SU

ED

F

OR

PS8-FOT-1 PS8-GENERATOR

T

T

2 4 3

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

C

R e v it P ro je c ts

\D R

Y D

P -1

-E

-P S ra k e m p .r v t

/2

/2

:4

:5

P

M

2-EG161

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

P U

M P

S T

A T

IO

N

LI

G

H

TN

IN

G

P R

O T

E C

TI

O

N A

N D

G R

O U

N D

IN

G

P

LA

N

RHS

12858034

JCC RAK

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL/TLH

1364315

N40085-22-R-2598

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

JAS

DSN

SHEET NOTES

1. PROVIDE A FRANKLIN ROD TYPE LIGHTNING PROTECTION SYSTEM IN

ACCORDANCE WITH NFPA780, AND UL96A. THIS IS A PERFORMANCE

BASED SYSTEM, DESIGN AND INSTALLATION MUST FOLLOW APPLICABLE

STANDARDS AND SPECIFICATIONS.

2. ALL SYSTEM MATERIALS MUST BE UL LISTED FOR LIGHTNING

PROTECTION SYSTEMS. LABEL ALL CONDUCTORS EVERY 10' WITH UL

LISTING.

3. ENSURE THAT MATERIALS USED ARE COMPATIBLE WITH THE ROOFING

SYSTEM. PROVIDE COPPER CONDUCTORS. DO NOT USED DISSIMILAR

METALS.

4. SEE ARCHITECTURAL ROOF PLAN FOR PRICING AND DESIGN PURPOSES.

5. SEE SHEET 2-EG502 FOR LIGHTNING PROTECTION DETAILS.

6. ELECTRICAL DISTRIBUTION GROUNDING MUST COMPLY WITH NEC ART.

250.

7. BOND ALL METAL HARDWARE SUCH AS LADDERS, VENT PIPING, ETC. AND

TO COORDINATE WITH ALL EXISTING STRUCTURES.

8. PATCH AND REPAIR EXISTING PAVED AREAS.

9. COMPLY WITH FAA STD-19F.

3/16" = 1'-0" A2

PUMP STATION 8 - LIGHTNING PROTECTION PLAN

0' 4' 8' 12'

PLAN

NORTH

PLAN

NORTH

KEY PLAN

PS-8

T

T

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/2

8/

1" = 10'-0" C2

PUMP STATION 8 - SITE EQUIPMENT GROUNDING PLAN

SHEET NOTES

1. PROVIDE GROUND CONNECTION TO PLATFORM REBAR AND FOUNDATION

PILE.

2. PROVIDE GROUND CONNECTION TO EQUIPMENT AND ENCLOSURE.

3. PROVIDE GROUND ROD TEST WELL; SEE1-ES516/C1.

4. PROVIDE GROUND CONNECTION TO PLATFORM HANDRAIL. IF HANDRAIL IS

NOT CONTINUOUS, BOND ALL NONCONTINOUS SECTIONS TOGETHER.

0" 10' 30'20'

PLAN

NORTH

IS

SU

ED

F

OR

NOTES:

1. THIS DETAIL DOES NOT PRECLUDE THE REQUIREMENTS OF

NEC ART. 250 OR NFPA 780. GROUNDING SYSTEM MUST

STRICTLY ADHERE TO NEC ART. 250, WHICH SUPERCEDES

THIS DETAIL.

2. BOND ALL METAL HARDWARE, SUCH AS STAIRS, LADDER,

ETC., TO THE ELECTRICAL GROUNDING SYSTEM.

N

G

MAIN GND BUS

(MGB) UPPER LEVEL

TYP OF ALL

MAJOR ELEC

EQUIPMENT

SWGR/PANEL BOARD

TYP.

ROOF LEVEL

LOWER LEVEL

TYP OF ALL

MAJOR MECH

EQUIPMENT

GENERATOR

GROUNDING COUNTERPOISEEXOTHERMIC WELD

TYP.

GROUNDING

ELECTRODE

CONDUCTOR

LIGHTNING PROTECTION DOWN

CONDUCTOR PER NFPA 780

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

C

R e v it P ro je c ts

\D R

Y D

P -1

-E

-P S ra ke m p .r v t

/2

/2

:3

:3

P

M

2-EG501

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

G R

O U

N D

IN

G

D E

T A

IL

S

RHS

12858035

JCC RAK

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL/TLH

1364315

N40085-22-R-2598

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

JAS

DSN

NOT TO SCALE

A2

TYPICAL GROUNDING RISER SCHEMATIC

SHEET NOTES

1. SEE 1-EG501 FOR ADDITIONAL GROUNDING DETAILS.

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R C

O N

S

TR

U C

T

IO

N

/2 8/

IS

SU

ED

F

OR

1.

2.

NOTES:

1. AIR TERMINALS OVER 24 INCHES

ARE SUPPORTED.

2. AIR TERMINAL SUPPORTS ARE

LOCATED AT A POINT NOT LESS

THAN ONE-HALF THE HEIGHT OF

THE AIR TERMINAL.

3'-0" MIN OFF DRIP LINE

PROVIDE MINIMUM #2 AWG GREEN INSULATED

COPPER DOWN CONDUCTOR

1" UV STABILIZED PVC CONDUIT

FOR DOWNCONDUCTORS.

MOUNT TO BUILDING

EXTERIOR WALL (TYP.)

AIR TERMINAL

ROUTE DOWN CONDUCTOR

ON OUTSIDE OF WALL

PROVIDE CLASS II MECHANICAL

CONNECTION

MAIN ROOF

CONDUCTOR

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

C

R e v it P ro je c ts

\D R

Y D

P -1

-E

-P S ra ke m p .r v t

/2

/2

:3

:3

P

M

2-EG502

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

LI

G

H

TN

IN

G

P R

O T

E C

TI

O

N D

E T

A

IL

S

RHS

12858036

JCC RAK

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL/TLH

1364315

N40085-22-R-2598

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

JAS

DSN

NOT TO SCALE

C2

AIR TERMINAL 24" OR TALLER ROOF MOUNTING DETAIL

NOT TO SCALE

C4

TYPICAL DOWN CONDUCTOR DETAIL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R C

O N

S

TR

U C

T

IO

N

/2 8/

IS

SU

ED

F

OR

ROOF TOS

136' - 0"

GRADING LEVEL

103' - 0"

SECOND LEVEL

121' - 0"

ENTRY LEVEL

109' - 0"

FIRST LEVEL

103' - 6"

C1E

PS6-1-3

C1E

PS6-1-3

8'

0" 8'

0"

C1

PS6-1-3

C1E

PS6-1-3

8'

0"

8'

0"

ROOF TOS

136' - 0"

GRADING LEVEL

103' - 0"

SECOND LEVEL

121' - 0"

ENTRY LEVEL

109' - 0"

FIRST LEVEL

103' - 6"

C1E

PS6-1-3

C1E

PS6-1-3

8'

0"

C1E

PS6-1-3

C1E

PS6-1-3

8'

0"

8'

0" 8'

0"

C1

2-EL151

A1

2-EL151

C1E C1E

A1E A1

A1 A1

A1 A1E

A1 A1

A1E A1

C2

PS6-1-3

C2

PS6-1-3

C2

PS6-1-3

C2

PS6-1-3

C1E C1E

15'-0" AFF

C2

PS6-1-3

C2

PS6-1-3

C2

PS6-1-3

C2

PS6-1-3

A1

PS6-1-2

A1

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

C

R e v it P ro je c ts

\D R

Y D

P -1

-E

-P S ra ke m p .r v t

/2

/2

:3

:4

P

M

2-EL151

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

P U

M P

S T

A T

IO

N

LI

G

H

TI

N G

P

LA

N

F

IR

S T

L E

V E

L

RHS

12858037

JCC RAK

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL/TLH

1364315

N40085-22-R-2598

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

JAS

DSN

SHEET NOTES

1. PENDANT MOUNT TYPE A2 LIGHTING FIXTURES, UON.

2. ALL OUTDOOR LIGHTING FIXTURES WILL BE CONTROLLED BY BUILDING

MOUNTED PHOTOCELL.

0' 4' 8' 12'

PLAN

NORTH

1/4" = 1'-0" C1

PUMP STATION 6 - LIGHTING ELEVATION - PLAN NORTH

1/4" = 1'-0" A1

PUMP STATION 6 - LIGHTING ELEVATION - PLAN SOUTH

2' 4' 8'0'

2' 4' 8'0'

PLAN

NORTH

KEY PLAN

PS-6

SHEET KEYNOTES

1. MOUNT FIXTURES 15'-0" ABOVE GRADING LEVEL.

2. MOUNT LIGHTING SWITCH 4'-0" ABOVE STRUCTURAL PLATFORM.

3/16" = 1'-0" (2-EL151)

A3

PUMP STATION 6 - LIGHTING PLAN - FIRST LEVEL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R C

O N

S

TR

U C

T

IO

N

/2 8/

IS

SU

ED

F

OR

C1E C1E

C1E

A1

PS6-1-1

A1E

A1 A1

A1E A1

A1 A1E

A1 A1

A1E A1

C1E

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

C

R e v it P ro je c ts

\D R

Y D

P -1

-E

-P S ra ke m p .r v t

/2

/2

:3

:4

P

M

2-EL152

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

P U

M P

S T

A T

IO

N

LI

G

H

TI

N G

P

LA

N

S E

C O

N D

L E

V E

L

RHS

12858038

JCC RAK

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL/TLH

1364315

N40085-22-R-2598

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

JAS

DSN

SHEET NOTES

1. PENDANT MOUNT TYPE A1 LIGHTING FIXTURES, UON.

2. ALL OUTDOOR LIGHTING FIXTURES WILL BE CONTROLLED BY BUILDING

MOUNTED PHOTOCELL.

0' 4' 8' 12'

PLAN

NORTH

PLAN

NORTH

KEY PLAN

PS-6

SHEET KEYNOTES

1. PROVIDE PHOTOCELL FOR CONTROL OF OUTDOOR LIGHTING FIXTURES.

3/16" = 1'-0" A2

PUMP STATION 6 - LIGHTING PLAN - SECOND LEVEL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R C

O N

S

TR

U C

T

IO

N

/2 8/

IS

SU

ED

F

OR

FIRST LEVEL

103' - 6"

ROOF/T.O.S.

136' - 0"

GRADING LEVEL

103' - 0"

SECOND LEVEL

121' - 0"

ENTRY LEVEL

109' - 0"

ROOF/T.O.S.

136' - 0"

SECOND LEVEL

121' - 0"

GRADING LEVEL

103' - 0"

C1E

PS8-1-8

C1E

PS8-1-8

8'

0" 8'

0"

C1E

PS8-1-8

8'

0" 8'

0"

C1E

PS8-1-8

FIRST LEVEL

103' - 6"

ROOF/T.O.S.

136' - 0"

GRADING LEVEL

103' - 0"

SECOND LEVEL

121' - 0"

ENTRY LEVEL

109' - 0"

ROOF/T.O.S.

136' - 0"

SECOND LEVEL

121' - 0"

GRADING LEVEL

103' - 0"

SECOND LEVEL

121' - 0"

C1E

PS8-1-8

8'

0" 8'

0"

C1E

PS8-1-8

C1E

PS8-1-8

8'

0" 8'

0"

C1E

PS8-1-8

B1

2-EL161

B3

2-EL161

C1E C1E

C2

PS8-1-8

C2

PS8-1-8

C2

PS8-1-8

C2

PS8-1-8

A1 A1E A1 A1 A1E

A1 A1 A1E A1 A1

1 1 1 1

2 2

C1E C1E

15'-0" AFF

C2

PS8-1-8

C2

PS8-1-8

C2

PS8-1-8

C2

PS8-1-81 1 1 1

A1

PS8-1-7

A1E

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

C

R e v it P ro je c ts

\D R

Y D

P -1

-E

-P S ra k e m p .r v t

/2

/2

:4

:5

P

M

2-EL161

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

P U

M P

S T

A T

IO

N

LI

G

H

TI

N G

P

LA

N

F

IR

S T

L E

V E

L

RHS

12858039

JCC RAK

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL/TLH

1364315

N40085-22-R-2598

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

JAS

DSN

SHEET NOTES

1. PENDANT MOUNT TYPE A2 LIGHTING FIXTURE, UON.

2. ALL OUTDOOR LIGHTING FIXTURES WILL BE CONTROLLED BY BUILDING

MOUNTED PHOTOCELL.

0' 4' 8' 12'

PLAN

NORTH

1/4" = 1'-0" B1

PUMP STATION 8 - LIGHTING ELEVATION - PLAN WEST

1/4" = 1'-0"

B3

PUMP STATION 8 - LIGHTING ELEVATION - PLAN EAST

0' 4' 8' 12'0' 4' 8' 12'

PLAN

NORTH

KEY PLAN

PS-8

SHEET KEYNOTES

1. MOUNT FIXTURES 15'-0" ABOVE GRADING LEVEL.

2. MOUNT LIGHTING SWITCH 4'-0" ABOVE STRUCTURAL PLATFORM.

3/16" = 1'-0" A2

PUMP STATION 8 - LIGHTING PLAN - FIRST LEVEL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/2

8/

IS

SU

ED

F

OR

3 3

C1E C1E

A1

PS8-1-9

A1 A1E A1 A1 A1E

A1A1A1EA1A1A1E

12'-0" AFF

C1EC1E

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

C

R e v it P ro je c ts

\D R

Y D

P -1

-E

-P S ra k e m p .r v t

/2

/2

:4

:5

P

M

2-EL162

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

P U

M P

S T

A T

IO

N

LI

G

H

TI

N G

P

LA

N

S E

C O

N D

L E

V E

L

RHS

12858040

JCC RAK

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL/TLH

1364315

N40085-22-R-2598

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

JAS

DSN

SHEET NOTES

1. PENDANT MOUNT TYPE A1 LIGHTING FIXTURE, UON.

2. ALL OUTDOOR LIGHTING FIXTURES WILL BE CONTROLLED BY BUILDING

MOUNTED PHOTOCELL.

0' 4' 8' 12'

PLAN

NORTH

PLAN

NORTH

KEY PLAN

PS-8

3/16" = 1'-0"

A2

PUMP STATION 8 - LIGHTING PLAN - SECOND LEVEL

SHEET KEYNOTES

1. PROVIDE PHOTOCELL FOR CONTROL OF OUTDOOR LIGHTING FIXTURES.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/2

8/

IS

SU

ED

F

OR

REVISED: SEPTEMBER 2020 TYPE: A1LIGHTING PLATE:

LUMINAIRE REQUIREMENTS:

HOUSING - LOW PROFILE, ONE-PIECE, FIBERGLASS HOUSING WITH INTEGRAL

PERIMETER CHANNEL.

LENS - INJECTION MOLDED, HIGH IMPACT-RESISTANCE ACRYLIC LENS.

LIGHT SOURCE - HIGH-EFFICIENCY LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,

3500K CCT UON, MINIMUM 80 CRI.

MOUNTING - SURFACE, WALL.6.

5.

4.

3.

2.

1.

7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE

THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE

A CERTAIN MANU FACTURER OR PREFERENCE.

CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.

COMPLIES WITH LM79, LM80, AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED

WITH EMERGENCY BATTERY BACK-UP.

DRIVER - INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF, OPERATING

VOLTAGE OF 120-277V, THERMAL MANAGEMENT, <20% TOTAL HARMONIC DISTORTION.

ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.

LED ENCLOSED AND GASKETED

4' NOMINAL

4 0.69

RCR

1.03

0.78 0.89

CU

NOMINAL 25W INPUT/

4000 LUMENS

TYPE A1

LPW - 160

MINIMUM

LED WALL PACK

REVISED: JANUARY 2014 TYPE: C1, C2LIGHTING PLATE:

LUMINAIRE REQUIREMENTS:

HOUSING - STAINLESS STEEL EXTRUDED HOUSING AND MILLED ENDCAPS.

FINISH - ELECTROSTATICALLY APPLIED POWDER COATED FINISH.

LENS - 100% ACRYLIC, FROSTED

ELECTRONIC DRIVER - IES LM-80 PERFORMANCE FOR 60,000

HOURS MINIMUM. SOUND RATING "A" WITH LESS THAN 20% THD, MINIMUM 0.9 POWER

FACTOR, INHERENT THERMAL PROTECTION, SHORT-CIRCUIT AND OVERLOAD

PROTECTION, AND COMPLIES WITH ANSI C62.41 CATEGORY A TRANSIENT PROTECTION.

PROVIDE 0-10V DIMMING DRIVER FOR 5-100% DIMMING RANGE OR BI-LEVEL STEP-

DIMMING IF INDICATED. PROVIDE WITH EMERGENCY BATTERY DRIVER.

CERTIFICATION - UL LISTED AND LABELED, DAMP LOCATION

6.

5.

4.

3.

2.

1.

MOUNTING - LUMINAIRE MUST HAVE A "FLANGLESS" AND FLUSH

APPEARENCE WHEN MOUNTED IN GYPSUM HARD CEILING OR WALL.

7. OPTICS - LUMINAIRE MUST PROVIDE A SYMMETRICAL DISTRIBUTION

PATTERN.

PHOTOMETRICS - MINIMUM VALUE OF COEFFICIENT OF

UTILIZATION (CU), GIVEN INTERIOR CAVITY REFLECTANCES OF

80-50-20:

8.

RCR CU

NOMINAL 25W INPUT/

4000 LUMENS

TYPE C1

LPW - 160

MINIMUM

0.84

1.10 1.01

0.92

RCR CU

NOMINAL 54W INPUT/

8000 LUMENS

TYPE C2

LPW - 150

MINIMUM

0.84

1.10 1.01

0.92

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

C

R e v it P ro je c ts

\D R

Y D

P -1

-E

-P S ra ke m p .r v t

/2

/2

:3

:4

P

M

2-EL501

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

LI

G

H

TI

N G

S C

H E

D U

LE

S

A N

D D

E

TA

IL

S

RHS

12858041

JCC RAK

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL/TLH

1364315

N40085-22-R-2598

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

JAS

DSN

LIGHT FIXTURES SCHEDULE

FIXTURE LAMP INFORMATION FIXTURE INFORMATION

TYPE TYPE COLOR TEMP

FIXTURE

LUMENS VOLTAGE WATTAGE DESCRIPTION MOUNTING

A1 LED 3500 K 4000 lm 277 V 25 W 4' ENCLOSED & GASKETED LED LUMINAIRE WITH SHALLOW ACRYLIC LINEAL

RIBBED FROSTED LENS

CEILING, SURFACE, PENDANT

C1 LED 3500 K 4000 lm 277 V 24 W EXTERIOR EGRESS WALLPACK. PROVIDE WITH EMERGENCY BATTERY

DRIVER.

WALL, SURFACE

C2 LED 3500 K 8000 lm 277 V 54 W EXTERIOR WALLPACK WALL, SURFACE, 14'-6" ABOVE GRADE, UON

LIGHTING CONTROL SCHEDULE

NAME CONTROLS

PUMP STATION 6 - SECOND LEVEL SW

PUMP STATION 6 - SUMP LEVEL SW

PUMP STATION 8 - SECOND LEVEL SW

PUMP STATION 8 - SUMP LEVEL SW

LIGHTING SEQUENCE OF OPERATIONS:

1. SPACES INDICATED WITH "SW" MUST HAVE THE FOLLOWING

FEATURES AND FUNCTIONS:

A. STANDARD LOCAL SNAP SWITCH FOR COMPLETE

MANUAL ON-OFF CONTROLL BY THE USER

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

IS

S U

E D

F O

R C

O N

S

TR

U C

T

IO

N

/2 8/

IS

SU

ED

F

OR

M

M

M

M

M

M

M

M

M

M M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

WPIU

GFI

WPIU

GFI

WPIU

GFI

WPIU

GFI

WPIU

GFI

FACP

PS6-SP-1

PS6-SP-2

PS6-P-3

PS6-P-2

PS6-P-1

PS6-DSS-CU-1

PS6-DSS-CU-2

PS6-DSS-CU-3

PS6-DSS-CU-4

PS6-3-12,14

PS6-3-13,15

PS6-3-8,10

PS6-DSS-2

PS6-DSS-3

D30

D30

D301

PS6-2-5

PS6-MONORAIL

RT

PS6-3-3

PS6-3-3

PS6-3-6

PS6-3-7

PS6-2-5

PS6-2-5

PS6-ACT-4

PS6-ACT-8

PS6-ACT-12

PS6-3-4

PS6-ACT-18

PS6-3-4

PS6-1-22,24,26

PS6-1-28,30,32

PS6-1-25,27,29

PS6-1-16,18,20

PS6-3-…