1364315_dwg_18of18_PH2_V4_Electrical.pdf
PDF 13 MB Posted
- Attached to
- P-678 Dry Dock 8 Saltwater System for CVN-78, Norfolk Naval Shipyard, Portsmouth, Virginia
- Solicitation number
- N40085-22-R-2598_Drawings
About this file
This document provides details for a federal contract opportunity to design and install a saltwater system for Dry Dock 8 at Norfolk Naval Shipyard in Portsmouth, Virginia. The solicitation number is N40085-22-R-2598 and related drawings and specifications can be accessed through Notice IDs N40085-22-R-2598_Drawings and N40085-22-R-2598_Specifications. The opportunity type is a special notice and the Naval Facilities Engineering Command is the contracting agency. Offerors are required to review the drawings and specifications to understand the full scope of designing and installing the saltwater system for Dry Dock 8, which will support maintenance of the aircraft carrier CVN-78. No pricing, response dates or other procedural details are provided in this document.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
POWER
SURFACE MOUNTED DUPLEX CONVENIENCE RECEPTACLE. 20A,
120V. GFI DENOTES GROUND FAULT INTERRUPTER, AC DENOTES
ABOVE COUNTER, WPIU DENOTES WEATHER PROOF ENCLOSURE
AND C DENOTES CEILING MOUNT (FLUSH).
SURFACE MOUNTED QUAD CONVENIENCE RECEPTACLE. 20A, 120V.
GFI DENOTES GROUND FAULT INTERRUPTER, AC DENOTES ABOVE
COUNTER, WPIU DENOTES WEATHER PROOF ENCLOSURE AND C
DENOTES CEILING MOUNT (FLUSH).
MOTOR RATED SWITCH OR MANUAL MOTOR STARTER WITH
OVERLOADS. M
M MOTOR / EQUIPMENT CONNECTION
HOMERUN TO PANEL. PANEL & CIRCUIT DESIGNATIONS AS
INDICATED.
MOTOR CONTROL / SAFETY SWITCH. 600V, 30A, IN NEMA 1
ENCLOSURE, UON. CROSS INDICATES COMINATION STARTER /
DISCONNECT, SLASH INDICATES COMBINATION VFD / SAFETY
SWITCH.
480Y/277V PANELBOARD.
208Y/120V PANELBOARD.
BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. CONDUIT
LARGER THAN 1/2" & WIRE LARGER THAN #12 MUST BE INDICATED.
FUSE SIZE IF INDICATED
DS30/F30
AMPACITY
D = SAFETY SWITCH
DS = COMBINATION STARTER / SAFETY SWITCH
V = VFD
ENCLOSED CIRCUIT BREAKER.
GROUNDING BUS BAR, MOUNT 7'-0" AFF UON.
SPD SURGE PROTECTIVE DEVICE
M DIGITAL METER
LIGHTING
120/277V TOGGLE SWITCH. SINGLE POLE, SUBSCRIPTS (A - E) WHEN
USED, DENOTES FIXTURES CONTROLLED.
TOGGLE SWITCH. SUBSCRIPT "3" = 3 WAY, "4" = 4 WAY.43
LED LUMINAIRE
LED EMERGENCY LUMINAIRE. EMERGENCY BATTERY DRIVER, 1400
LUMENS MINIMUM FOR 90 MINUTES, UON (NOTE: ALL FIXTURES
NOTED ON PLAN WITH HATCH AND/OR LABELED WITH AN 'E' AFTER
THE FIXTURE TYPE INDICATES EMERGENCY)
'E' DENOTES EMERGENCY F1E
MOUNTING HEIGHT
MUST BE SAME AS CEILING UON.
LOWER CASE LETTER DENOTES SWITCH
'LEG'. THE SWITCH WITH THE SAME
LETTER OPERATES THIS FIXTURE.
LUMINAIRE TYPE
8'-0" a
GROUND ROD, SUBSCRIPT INDICATES TYPE.
T: TEST WELL; SEE 1-ES516/C1
AIR TERMINAL.
DOWN CONDUCTOR.
LIGHTING PROTECTION AND GROUNDING
ROOF MAIN CONDUCTOR.
GENERAL
KEYNOTE TAG - REFER TO SHEET KEYNOTES ON EACH SHEET?
ABBREVIATIONS
Ø PHASE
1/C ONE CONDUCTOR
A AMPERAGE OR AMPS
AFF ABOVE FINISHED FLOOR
ARF ABOVE RAISED FLOOR
AHU AIR HANDLING UNIT
BKR BREAKER
CONDUIT
CIRCUIT BREAKER
CIRCUIT
DRAWING
EACH
EMPTY CONDUIT
ELECTRICAL
ELECTRICAL METALLIC TUBING
ENCLOSURE
EQUIPMENT
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
EXISTING
EXPLOSION PROOF EQUIPMENT
FAN COIL UNIT
FEET
GOVERNMENT FURNISHED CONTRACTOR INSTALLED
GOVERNMENT FURNISHED EQUIPMENT
GOVERNMENT FURNISHED GOVERNMENT INSTALLED
GROUND FAULT INTERRUPTER
GROUND
HEIGHT
HIGH INTENSITY DISCHARGE
HORSEPOWER
COMPUTER DISTRIBUTION HUB
LIGHT EMITTING DIODE
LUMINAIRE
MAIN CIRCUIT BREAKER
MAIN DISTRIBUTION PANEL
MECHANICAL
MAIN LUGS ONLY
MOUNTED
MOUNTING HEIGHT
NATIONAL ELECTRICAL CODE
NON FUSIBLE
NOT IN CONTRACT
NIGHT LIGHT
NOT TO SCALE
OUTLET BASE INFEED
OCCUPANCY SENSOR
PANEL
PANELBOARD
POLYVINYL CHLORIDE CONDUIT
QUANTITY
RECEPTACLE
REQUIRED
RIGID GALVANIZED STEEL
ROOM
SHEET
SUBSTATION
SWITCHBOARD
TELEPHONE
TYPICAL
UNLESS OTHERWISE NOTED
UNINTERUPTABLE POWER SUPPLY
WIRE
WEATHERPROOF WHILE IN USE
WIREWAY (TROUGH)
IN SCHEDULES, ITEM NOT APPLICABLE
VARIABLE REFRIGERANT FLOW UNIT
BH BASEBOARD HEATER
C
CB
CKT
DWG
EA
EC
ELEC
EMT
ENCL
EQUIP
EWC
EWH
EXIST
EXP
FCU
FT
GFCI
GFE
GFGI
GFI
GND
HGT
HID
HP
HUB
LED
LTS
MCB
MDP
MECH
MLO
MTD
MTG HT
NEC
NF
NIC
NL
NTS
OBI
OC
PNL
PNLBD
PVC
QU
REC
REQ'D
RGS
RM
SHT
SUB
SWBD
T
TYP
UON
UPS
VRF
W
WPIU
WW
X
TRANSFORMERXFMR
VARIABLE FREQUENCY DRIVEVFD
PANEL LP1A
100A, 208Y/120V-30, 4W
FEEDS FROM PANEL MDP
DEVICE ID
DEVICE RATING
POWER SOURCE
SWITCHGEARSWGR
GROUND RING COUNTERPOISE.
PROGRAMMABLE LOGIC CONTROLLERPLC
PLC PROGRAMABLE LOGIC CONTROLLER
PANEL - CIRCUIT NUMBERPA-1,3,5
NORMALLY OPENN.O.
VOLTAGE OR VOLTSV
MEDIUM VOLTAGE CIRCUIT BREAKER
MEDIUM VOLTAGE DRAW OUT CIRCUIT BREAKER
CURRENT TRANSFORMER
TRANSFORMER
LOW VOLTAGE CIRCUIT BREAKER
XXX - Y
ONE LINE DIAGRAM WIRE SIZE TAG; SEE 1-EP501/B2
XXX: AMPERAGE RATING OF THE CONDUCTORS
Y: NUMBER OF CONDUCTORS
T
RADIO TRANSMITTERRT
FIRE ALARM CONTROL PANELFACP
CONTRACT LINE ITEMCLIN
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
C
R e v it P ro je c ts
\D R
Y D
P -1
-E
-P S ra ke m p .r v t
/2
/2
:3
:3
P
M
2-E-001
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
LE
G
E N
D , A
B B
R E
V
IA
TI
O
N S
A N
D G
E N
E R
A L
N O
TE
S
RHS
12858021
JCC RAK
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL/TLH
1364315
N40085-22-R-2598
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
JAS
DSN
GENERAL NOTES
1. ALL 2-E-001 SYMBOLS, ABBREVIATIONS, AND NOTES APPLY ONLY TO ED, EG,
EL, AND EP SERIES SHEETS. FOR ALL SITE ELECTRICAL SYMBOLS,
ABBREVIATIONS, AND NOTES SEE 2-E-011 AND 2-E-012.
2. PROVIDE EQUIPMENT GROUND WIRE(S) WITH FEEDERS AND BRANCH
CIRCUITS.
3. PROVIDE WIRING PER NATIONAL ELECTRICAL CODE (NEC).
4. LABEL AND IDENTIFY ELECTRICAL EQUIPMENT.
5. IDENTIFY FEEDERS/CIRCUITS AT EACH END OF THE WIRE AND AT EVERY
SPLICE OR JUNCTION/PULL BOX.
6. PROVIDE NAMEPLATES ON THE EXTERIOR OF ELECTRICAL PANELS AND
ENCLOSURES AS FOLLOWS:
FOR SAFETY SWITCHES, MOTOR STARTERS & VFDs, INSCRIBE THE TOP
LINE WITH THE NAME/DESIGNATION OF EQUIPMENT BEING FED BY SAME.
7. PROVIDE TYPED DIRECTORIES FOR PANELS (NEW OR EXISTING).
INCLUDED IN THIS PROJECT.
8. INTERIOR WIRING SYSTEMS MUST BE CONCEALED WITH FLUSH MOUNTED
BOXES/DEVICES, UON.
9. DRAWINGS ARE BASED ON EXISTING BUILDING PLANS AND FIELD
INVESTIGATIONS. VISIT THE EXISTING BUILDING AND ACQUAINT
HIMSELF/HERSELF WITH THE EXISTING CONDITIONS. EXAMINE EXISTING
DRAWINGS TO AVOID CONFLICTS.
10. COORDINATE LOCATION AND POWER REQUIREMENTS OF ELECTRICAL
DEVICES WITH MECHANICAL, PLUMBING, ARCHITECTURAL AND FIRE
PROTECTION DRAWINGS.
11. ELECTRICAL DEVICES SHOWN BUT NOT CIRCUITED MUST REMAIN ON THEIR
EXISTING CIRCUIT.
12. PROVIDE ARC-FLASH LABELS ON ALL SWITCHBOARDS / SWITCHGEAR /
PANELS / SAFETY SWITCHES / MOTOR STARTS / VFDs PER UFC 3-560-01
AND NFPA 70E. SEE DETAIL PLATE ON SHEET 2-EP-501.
13. SINGLE PHASE (120/208V) BRANCH CIRCUITS MUST CONSIST OF 2 #12, #12 G
IN 1/2" C, UON. THREE PHASE BRANCH CIRCUITS CONSIST OF 3 #12, #12 G IN
1/2" C, UON.
14. REFER TO PLANS FOR CONDUCTOR SIZING. COMPLY WITH THE
FOLLOWING GUIDELINES FOR CONDUCTOR RUN LENGTHS:
20A,120V CIRCUITS LONGER THAN 100' - USE #10 AWG TO LIMIT VOLTAGE
DROP ON BRANCH CIRCUITS TO 3%
20A, 120V CIRCUITS LONGER THAN 150' - USE #8 AWG TO LIMIT VOLTAGE
DROP ON BRANCH CIRCUITS TO 3%
20A, 277V CIRCUITS LONGER THAN 150' - USE #10 AWG TO
LIMIT VOLTAGE DROP ON BRANCH CIRCUITS TO 3%
15. COORDINATE ELECTRICAL WORK WITH ARCHITECTURAL, MECHANICAL AND
FIRE PROTECTION WORK PRIOR TO FABRICATION AND INSTALLATION TO
PREVENT CONFLICTS. NOTIFY THE CONTRACTING OFFICER WHERE
CONFLICTS ARE DISCOVERED PRIOR TO CONSTRUCTION AND BEFORE
BEGINNING WORK IN THOSE AREAS. ALL CONFLICTS THAT ARISE DUE TO
LACK OF COORDINATION MUST BE RECTIFIED AT NO COST TO THE
GOVERNMENT.
16. SEE SECTION 26 05 48.00 10 SEISMIC PROTECTION FOR ELECTRICAL
EQUIPMENT FOR ALL SYSTEMS REQUIRING SEISMIC BRACING, AND
SEISMICALLY RATED EQUIPMENT.
17. SEE PHASE 1 ELECTRICAL DRAWINGS FOR ALL DETAILS NOT SHOWN IN
PHASE 2 ELECTRICAL DRAWINGS.
18. CLIN EQUIPMENT IS ONLY INDICATED ON 2-EP1** AND 2-EP2** SERIES
SHEETS.
CONSTRUCTION NOTES
1. PROVIDE WRITTEN REQUESTS TO THE CONTRACTING OFFICER A MINIMUM
OF 14 CALENDAR DAYS PRIOR TO ANY POWER OUTAGES.
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R C
O N
S
TR
U C
T
IO
N
/2 8/
IS
SU
ED
F
OR
B
ID
D E
P A
R T
M E
N T
O
F
T
H
A V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
C
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
L
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
R
I D
ELECTRICAL LEGEND-(EXTERIOR UNDERGROUND)
UNDERGROUND DUCTBANK, CONCRETE ENCASED UON. DESCRIPTION AS INDICATED
EXISTING UNDERGROUND DUCTBANK, CONCRETE ENCASED UON. DESCRIPTION AS INDICATED
REMOVE EXISTING UNDERGROUND DUCTBANK, CONCRETE ENCASED UON DESCRIPTION AS INDICATED
UNDERGROUND CONDUIT DESCRIPTION AS INDICATED
EXISTING UNDERGROUND CONDUIT DESCRIPTION AS INDICATED
SYMBOL REFERS TO DEPTH OF DUCTBANK SECTION. SEE DUCTBANK DETAILS
UNDERGROUND ELECTRICAL DISTRIBUTION CONCRETE ENCASED DUCTBANK SECTION LOOKING IN DIRECTION OF
ARROWS
SPARE DUCT (TYPICAL). DESCRIPTION PER CABLE AND CONDUIT SCHEDULES ON SHEET 1-ES603
HEAVY LINE INDICATES BOTTOM OF DUCT
EXISTING CABLE DESIGNATION WITHIN CIRCLE (TYPICAL) DESCRIPTION PER CABLE AND CONDUIT SCHEDULES
ON SHEET 1-ES603
OCCUPIED CONDUIT, UNIDENTIFIED EXISTING CABLE
CABLE DESIGNATION (TYPICAL)
DESCRIPTION PER CABLE AND CONDUIT SCHEDULES ON SHEET 1-ES603
GROUNDING CONDUCTOR
EXOTHERMIC CONNECTION
GROUND ROD
MANHOLE OR HANDHOLE AS NOTED
EQUIPMENT CODE CLEARANCE
EQUIPMENT MAINTENANCE/VENTILATION CLEARANCE
EQUIPMENT MAINTENANCE/VENTILATION AND EGRESS CLEARANCE
JUNCTION BOX
LIGHT POLE
SPEAKER
EQUIPMENT CONNECTION
MOTOR CONNECTION, HP INDICATED
GENERATOR AS NOTED
DISCONNECT SWITCH, 600V IN NEMA 4X ENCLOSURE UON
3P = NO. OF POLES, 60 = SWITCH RATING, 40 = FUSE RATING
(NF INDICATES NON-FUSIBLE)
MOTOR CONTROLLER BY DIVISION 21 CONTRACTOR
EQUIPMENT AS NOTED
ELECTRICAL PANELBOARD (208Y/120 VOLT)
ELECTRICAL PANELBOARD (480Y/277 VOLT)
REMOVE EXISTING EQUIPMENT INDICATED
LIMIT OF DEMOLITION
NEW TO EXISTING CONNECTION
LIGHTING FIXTURE TYPE
COPING WALL JUNCTION CHAMBER
L - LIGHTING
F
P - PUBLIC ADDRESS
2 S1
X N1
J
M
3P
ELECTRICAL LEGEND (ONE-LINE & RISER DIAGRAMS)
POWER TRANSFORMER
POTENTIAL TRANSFORMER
CONTROL POWER TRANSFORMER
SURGE ARRESTOR
FUSED SWITCH
SWITCH
TRANSFER SWITCH
MOLDED CASE CIRCUIT BREAKER
LOW VOLTAGE DRAW-OUT POWER CIRCUIT BREAKER
MEDIUM VOLTAGE POWER CIRCUIT BREAKER
POWER DRAW OUT CIRCUIT BREAKER
GROUNDED WYE CONNECTION
UNGROUNDED WYE CONNECTION
CURRENT TRANSFORMER - SINGLE RATIO AS SHOWN
SURGE PROTECTIVE DEVICE
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
CONTROL SWITCH
CABLE TERMINATIONS
GROUNDING ELECTRODE CONNECTION
CABLE OR BUS, TYPE AND CHARACTERISTICS AS INDICATED
EXISTING CABLE OR BUS, TYPE AND CHARACTERISTICS AS INDICATED
NEW TO EXISTING CABLE SPLICE OR TAP
HOMERUN TO PANELBOARD. NO. OF ARROWS INDICATE NO. OF CIRCUITS.
TICKMARKS INDICATE NO. OF AWG CONDUCTORS.
REMOVE CABLE OR BUS, TYPE AND CHARACTERISTICS AS INDICATED
RELAY AND ANSI CONTROL FUNCTION SYMBOL.
CONTACTS - NORMALLY OPEN
CONTACTS - NORMALLY CLOSED
FUSE
GROUND
PUSHBUTTON
WHD METER
ASTRONOMICAL TIME CLOCK
PT
CPT
CT
600/S
ABBREVIATIONS
ELECTRICAL LEGEND (MISCELLANEOUS)
KEYNOTE SYMBOL
SPD
PT
CS
1/C SINGLE CONDUCTOR
3/C THREE CONDUCTOR
A AMP/AMPERE
AC ALTERNATING CURRENT
AF AMPERE FRAME
AFF ABOVE FINISHED FLOOR
AIC AMPS INTERRUPTING CAPACITY
AMI ADVANCED METERING INFRASTRUCTURE
AS AIR SWITCH
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAGE
BFG BELOW FINISHED GRADE
BLDG. BUILDING
BOD BASIS OF DESIGN
BRKR BREAKER
C CONDUIT
CAP CAPSTAN
CB CIRCUIT BREAKER
CFM CUBIC FEET/MINUTE
CHP CRANE HOTEL POWER
CKT CIRCUIT
CLR CLEAR
CONT CONTINUOUS
CPT CURRENT POTENTIAL TRANSFORMER
CST COMMUNICATIONS SHORE TIE
CT CURRENT TRANSFORMER
CU COPPER
D DEPTH
DDC DIRECT DIGITAL CONTROL
DIST DISTRIBUTION
DPDT DOUBLE POLE DOUBLE THROW
ECB ENCLOSED CIRCUIT BREAKER
EDC ENVIRONMENTAL DISTRIBUTION CENTER
EMH ELECTRIC MANHOLE
EPR ETHYLENE PROPYLENE RUBBER
EQ EQUAL
EQUIP EQUIPMENT
EX,EXIST EXISTING
FA FIRE ALARM
FLA FULL LOAD AMPS
FO FIBER OPTIC CABLE
FPMT FUTURE PAD-MOUNTED TRANSFORMER
GFI/GFCI GROUND FAULT CURRENT INTERRUPTER
GND GROUND
GOVT GOVERNMENT
GS GAS SWITCH
H HEIGHT
HMI HUMAN MACHINE INTERFACE
HOA HAND-OFF-AUTOMATIC
HP HORSE POWER
HPS HIGH PRESSURE SODIUM
JBOX JUNCTION BOX
KAIC THOUSAND AMPERE INTERRUPTING CAPACITY
KCMIL/MCM THOUSAND CIRCULAR MILS
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATT
L LENGTH, ANGLE
LAN LOCAL AREA NETWORK
LTS LIGHTS
LV LOW VOLTAGE
LVCB LOW VOLTAGE CONNECTION BOX
LVST LOW VOLTAGE SHORE TIE STATION
MCB MAIN CIRCUIT BREAKER
MAX MAXIMUM
MESG METAL ENCLOSED INTERRUPTER SWITCHGEAR
MH MANHOLE
MIN MINIMUM
MM MULTIMODE
MT MOUNT
MTG HT MOUNTING HEIGHT
MV MEDIUM VOLTAGE
MVA THOUSAND KILOVOLT VOLT AMPERES
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NESC NATIONAL ELECTRICAL SAFETY CODE
NF NON FUSED
NNSY NORFOLK NAVAL SHIPYARD
N.O. NORMALLY OPEN
NO. NUMBER
NTS NOT TO SCALE
NU NAVFAC UTILITIES
O/C ON CENTER
OSP OUTSIDE PLANT
P POLE
PA PUBLIC ADDRESS
PLC PROGRAMMABLE LOGIC CONTROL
PMS PAD-MOUNTED SWITCH
PMT PAD-MOUNTED TRANSFORMER
PT POTENTIAL TRANSFORMER
PW PUMPWELL
PVC POLYVINYL CHLORIDE
REC RECEPTACLE
REOL REMOVABLE END OF LINE RESISTOR
REQ'D. REQUIRED
RSC RIGID STEEL CONDUIT
RTU REMOTE TERMINAL UNIT (SCADA)
SCADA SUPERVISORY CONTROL AND DATA AQUISITION
SCH SCHEDULE
SE SERVICE ENTRANCE
SER SERVICE ENTRANCE RATED (UL LISTED)
SM SINGLE-MODE
SMFO SINGLE MODE FIBER OPTIC
SPA SPACE, SPACING
SMH SIGNAL MANHOLE
SS STAINLESS STEEL
SUB SUBSTATION
T TRANSFORMER
TB TURTLEBACK
TOD TOP OF DUCTBANK ELEVATION
TOM TOP OF MANHOLE ELEVATION
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
UL UNDERWRITERS LABORATORIES
V VOLT, VOLTAGE
VAC VOLTS ALTERNATING CURRENT
VFI VACUUM FAULT INTERRUPTER
W WATT, WIRE, WIDTH
WI WEATHERPROOF IN-USE
WP WEATHERPROOF
XFMR TRANSFORMER
E
G
WHD
ATC
S
A
J
FEEDER DESIGNATION. SEE SCHEDULES
FIRE ALARM PULL BOX, 18" X 12" X 18"
J
GROUND TEST PIT
DZ RAD WAS
12858022
L E
G E
N D
A
B B
R E
V I A
T I O
M
B O
L S
2-E-011
AS NOTED
P A
R T
M E
T
V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
D
1. ALL 2-E-011 AND 2-E-012 SYMBOLS, ABBREVIATIONS AND NOTES APPLY ONLY TO ED AND ES
SERIES SHEETS.
2. CONDUIT AND DUCT ROUTINGS SHALL NOT INTERFERE WITH NEW OR EXISTING EQUIPMENT,
PIPING, OR CONDUIT AND SHALL NOT OBSTRUCT ACCESS TO ANY EQUIPMENT.
3. THE EQUIPMENT GROUND CONDUCTOR SHALL BE CONNECTED TO ALL DEVICES SUCH THAT
REMOVAL OF ANY DEVICE CANNOT INTERRUPT THE CONTINUITY OF THE EQUIPMENT
GROUNDING CONDUCTOR TO AND FROM OTHER DEVICES OR EQUIPMENT.
4. WIRE AND CONDUIT FOR EQUIPMENT AND MOTOR LOADS SHALL BE CONTINUOUS IN SIZE AND
COUNT FROM THE SOURCE TO THE FINAL CONNECTION. SIZE AND COUNT SHALL BE AS
INDICATED ON THE CIRCUIT HOMERUN OR FEEDER SCHEDULE, UNLESS OTHERWISE NOTED.
5. CONTRACTOR SHALL PERFORM A FEEDER, MANHOLE AND DUCT-ROUTE SURVEY PRIOR TO
BEGINNING CONSTRUCTION TO VERIFY THE ROUTING OF THE EXISTING FEEDERS,
AVAILABILITY OF EXISTING MANHOLES AND DUCTS INTENDED TO BE USED. PROVIDE THE
CONTRACTING OFFICER WITH RESULTS OF THIS SURVEY AND SKETCH OF DUCTBANK
SECTIONS SHOWING LOCATIONS OF OCCUPIED DUCTS AND CABLES TO BE INSTALLED.
6. THE CONTRACTOR SHALL DE-WATER MANHOLES AND HANDHOLES BEFORE COMMENCING
WORK. THE CONTRACTORS DE-WATERING PUMPS SHALL BE AVAILABLE IN CASE WATER
SEEPAGE DOES NOT SUBSIDE. UNDER NO CIRCUMSTANCES SHALL OPEN CABLE SPLICES OR
CUT TERMINATIONS EVER COME IN CONTACT WITH WATER.
7. UNLESS SPECIFICALLY NOTED TO BE EXISTING, ALL WORK AND MATERIAL SHALL BE
PROVIDED BY THE CONTRACTOR. WHEREVER AN EXISTING TO PROPOSED CONNECTION IS
REQUIRED, PROVIDE EXTENSION RINGS, SPLICES, WIRE, CONDUIT FITTINGS, AND
ASSOCIATED APPURTENANCES. PERFORM ALL CUTTING AND PATCHING AS REQUIRED TO
MAKE THE CONNECTIONS.
8. THE CONTRACTOR SHALL COORDINATE INSTALLATION OF ALL COMMUNICATIONS (NAVFAC
UTILITIES, SCADA, ETC.) CABLES AND EQUIPMENT INTO EXISTING FACILITIES AND BUILDINGS
WITH CONTRACTING OFFICER AND NNSY PRIOR TO COMMENCING THIS WORK.
COORDINATION AND DISCUSSION BETWEEN ALL PARTIES INVOLVED WITH THIS WORK SHALL
TAKE PLACE IN WEEKLY MEETING AND ADDITIONAL MEETINGS AS REQUIRED ESPECIALLY
FOR THIS PURPOSE.
9. THE CONTRACTOR SHALL CLOSELY STUDY THE CONSTRUCTION PLANS AND NOTES AS
OUTLINED. SLIGHT DEVIATIONS FROM CONFINED WORK SPACES MAY BE NECESSARY TO
FULLY COMPLETE A CONSTRUCTION AREA AS OUTLINED ON THOSE SHEETS. THE DEVIATIONS
SHALL BE HELD TO A MINIMUM AND SHALL BE FULLY COORDINATED WITH THE CONTRACTING
OFFICER. ALL SUCH DEVIATIONS SHALL BE MADE WITH NO ADDITIONAL COST TO THE
GOVERNMENT.
10. DURING THE EXECUTION OF THIS WORK, THE GOVERNMENT WILL CONTINUE TO OCCUPY AND
OPERATE ALL ADJACENT FACILITIES, PIERS, BERTHS, WHARFS, BUILDINGS AND UTILITIES,
AND, THEREFORE, WILL REQUIRE CONTINUOUS OPERATION OF ALL EXISTING ELECTRIC AND
TELECOMMUNICATIONS SERVICES. OUTAGES REQUIRED FOR CONSTRUCTION PURPOSES
SHALL BE SCHEDULED FOR THE SHORTEST PRACTICAL PERIODS OF TIME, AND THEN ONLY
BY PRE-ARRANGEMENT WITH THE CONTRACTING OFFICER FOR MUTUALLY AGREEABLE
PERIODS. AFTER EACH OF WHICH THE INTERRUPTION SHALL CEASE AND SERVICE SHALL BE
RESTORED.
11. THE CONTRACTOR SHALL PERFORM WORK ON UNENERGIZED CABLES WITH ENERGIZED
CABLES IN MANHOLE.
12. SPLICING OF FEEDERS WITHIN MANHOLES OR UNDERGROUND IS DISCOURAGED.
13. PLATFORM MOUNTED EQUIPMENT (SUBSTATIONS, MV SWITCVHES, SWITCHGEAR,
GENERATORS, FUEL STORAGE SYSTEMS, ETC.) LAYOUT IS PARTIALLY DIAGRAMMATIC.
CONTRACTOR SHALL VERIFY THE CODE REQUIRED CLEARANCES FOR APPROVED
EQUIPMENT AND ADJUST THE EQUIPMENT LAYOUT, DUCTBANK AND CONDUIT ROUTING, AND
SUPPORTING STRUCTURES AS NECESSARY.
1. COORDINATE ALL DUCTBANK ROUTING WITH EXISTING AND NEW STRUCTURES, INCLUDING
PLATFORM PILES. ROUTE DUCTBANKS TO AVOID CONFLICTS.
2. LOCATIONS AND ROUTING OF CONDUITS, DUCTBANKS AND ELECTRICAL STRUCTURES SHOWN
ON THE DRAWINGS ARE APPROXIMATE. PRIOR TO EXCAVATION AND INSTALLATION, THE
CONTRACTOR SHALL COORDINATE AND VERIFY LOCATIONS, ROUTING AND DEPTHS OF ALL
CONDUITS, DUCTS AND STRUCTURES WITH ALL OTHER TRADES TO AVOID CONFLICTS WITH ALL
NEW AND EXISTING UTILITIES AND STRUCTURAL FEATURES.
3. THE CONTRACTOR SHALL COORDINATE THE ROUTING OF THE DUCTBANKS AND MAKE ANY
ADJUSTMENTS REQUIRED IN HORIZONTAL AND VERTICAL DIRECTIONS OF THE ENTIRE
DUCTBANK RUN TO MISS ANY UTILITIES INCLUDING OTHER DUCTBANKS. THE ADJUSTMENTS
SHALL CONSIDER THE ENTIRE CABLING RUN SHALL NOT EXCEED 360 DEGREES WORTH OF
BENDS BETWEEN PULLING POINTS IN A SINGLE RUN PER THE NEC.
4. PROVIDE 20 MIL PLASTIC SHEETING IN BETWEEN DUCTBANKS WHERE DUCTBANKS COME IN
CONTACT.
5. PROVIDE PULL STRING IN EVERY DUCT WHERE EXISTING CABLING IS REMOVED PER
DEMOLITION DRAWINGS.
GENERAL DEMOLITION NOTES:
1. SEE DEMOLITION ONE-LINE DIAGRAMS AND CABLE SCHEDULES ON ES600 SERIES SHEETS.
2. REMOVE CONDUCTORS FROM CONDUITS AND DUCTS AND DISCONNECT FROM ALL POWER
SOURCES AS REQUIRED TO ACCOMPLISH THE WORK OF THIS CONTRACT. REFER TO SHEETS ED
SERIES DRAWINGS FOR DEMOLITION, INCLUDING UTILITIES, DUCTBANKS AND OTHER
STRUCTURES.
3. DEMOLITION OF DUCTBANKS SHALL INCLUDE REMOVAL OF SECTIONS INDICATED IN ED100
SERIES DRAWINGS. ALL MANHOLES ARE EXISTING TO REMAIN, UON.
4. EXCEPT AS NOTED ELSEWHERE AND AS REQUIRED BY CONSTRUCTION PHASING, ALL EXISTING
SERVICES (ELECTRIC, TELEPHONE, LAN, NAVFAC UTILITIES, CATV, PA, NAVFAC UTILITIES
SECURITY, ETC.) SHALL REMAIN ACTIVE.
5. THE ENTIRE RUN OF ABANDONED CONDUITS WITHIN DUCTBANKS SHALL BE GROUTED
COMPLETE. GROUT ABANDONED CONDUITS WITHIN DUCTBANKS FLUSH WITH THE INTERIOR OF
MANHOLES AND FLUSH WITH THE ENDS OF THE CONDUITS.
6. SEE ELECTRICAL GENERAL NOTES FOR ADDITIONAL DEMOLITION AND REDISTRIBUTION
REQUIREMENTS.
ELECTRICAL GENERAL NOTES (APPLICABLE TO ALL SHEETS)ELECTRICAL GENERAL DUCTBANK NOTES
GENERAL CONSTRUCTION NOTES:
1. THE CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING OFFICER FOR OTHER WORK
AROUND DRY DOCK 8.
2. SCHEDULE WORK AROUND ALL TEMPORARY AND PERMANENT EQUIPMENT ASSOCIATED WITH
THE GOVERNMENT WORK IN DRY DOCK 8.
3. ALL OUTAGES REQUIRED WILL BE SCHEDULED WITH THE GOVERNMENT AT LEAST 30 DAYS
PRIOR. THE CONTRACTOR SHALL WORK AROUND THE SCHEDULE OF THE GOVERNMENT WITHIN
DRY DOCK 8.
DZ RAD WAS
12858023
G E
N E
R A
L
N
O T
E S
2-E-012
EMH-584
EMH-583A
EMH-583
2 4 6
2 4 6
2 4 6
SUBSTATION Z15
SUBSTATION Z-1B3
2 4 6
BUILDING #271
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
D E
P A
R T
M E
T
V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
D
SHEET NOTES
NORTH
PLAN
KEY PLAN
4 5
11 12
2 3
13 14
SHEET KEYNOTES
SCALE: 1" = 20'
PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 4
A1
PLAN
NORTH
40'10'0 20'
1. DISCONNECT FEEDER 30 FROM AIR SWITCH AS-5 INSIDE BUILDING
271.
2. REMOVE FEEDER 30 CONDUCTORS FROM DUCTBANK.
3. DISCONNECT FEEDER 28 FROM SUBSTATION Z-1B DISTRIBUTION
CIRCUIT BREAKER INSIDE BUILDING 271.
4. REMOVE FEEDERS 28 CONDUCTORS FROM DUCKBANK.
5. DISCONNECT FEEDER 29 FROM SUBSTATION Z1 DISTRIBUTION
CIRCUIT BREAKER INSIDE BUILDING 271.
6. REMOVED FEEDER 29 CONDUCTORS FROM DUCKBANK.
1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.
2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
MATCH LINE
A1/2-ED129
DZ RAD WAS
12858024
E L
E C
T R
I C
T
E
D
E M
O L
I T
I O
N
P
L A
N
A
R E
A
2-ED124
EMH-877
TMH-1498
EMH-1499
EMH-1501
TMH-1-10
062306
062306
F1
23XX
230606
060606
060606
XX
XX
XX
X
X
XX 06
X
X
X
060606 06 0606 06 06
F1
D E
P A
R T
M E
T
V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
D
SHEET NOTES
NORTH
PLAN
KEY PLAN
4 5
11 12
2 3
13 14
MATCH LINE
A1/2-ED132
M A
T C
H
L I N
E
A E
D
SCALE: 1" = 20'
PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 7
A1
PLAN
NORTH
40'10'0 20'
1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.
2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
DZ RAD WAS
12858025
E L
E C
T R
I C
T
E
D
E M
O L
I T
I O
N
P
L A
N
A
R E
A
2-ED127
EMH-1501
TMH-1-11
EMH-N11
PRIMARY UNIT SUBSTATION
DD8-S/S-1N
MV SWITCH DD8-G/S-3N
REFER TO "ENLARGED PLAN - SUBSTATION
PLATFORM" ON SHEET 2-E-405
F1
060606
062315
062317
062306
X
X
060606
23XX
230606
060606
060606
XX
XX
XX
X
X
XX 06
X
X
X
060606 06 0606 06 06
F1
D E
P A
R T
M E
T
V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
D
SHEET NOTES
NORTH
PLAN
KEY PLAN
4 5
11 12
2 3
13 14
MATCH LINE
A1/2-ED133
M A
T C
H
L I N
E
A E
D
M A
T C
H
L I N
E
A E
D
SCALE: 1" = 20'
PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 8
A1
PLAN
NORTH
40'10'0 20'
1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.
2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
DZ RAD WAS
12858026
E L
E C
T R
I C
T
E
D
E M
O L
I T
I O
N
P
L A
N
A
R E
A
2-ED128
EMH-N12
MV SWITCH
DD8-G/S-2N
MV
SWITCH
DD8-G/S-1N
TMH-1-12
EMH-585
EMH-866
EMH-865
EMH-864
EMH-863
CAPSTAN 34
M18
EMH-862
EMH-861
1 2 1 2
BUILDING #273
X
X
X
X
X
060606
X
X
X
X
X
M5
X
X
C1
X
X
X
X
X
M5
X
X
C1
04 X
X
M6
X
X
C1
04 04
C1
M6
D E
P A
R T
M E
T
V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
D
SHEET NOTES
NORTH
PLAN
KEY PLAN
4 5
11 12
2 3
13 14
SCALE: 1" = 20'
PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 9
A1
PLAN
NORTH
40'10'0 20'
1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.
2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
MATCH LINE
A1/2-ED134
M A
T C
H
L I N
E
A E
D
M A
T C
H
L I N
E
A E
D
1. REMOVE POWER FEEDER M6 FROM EMH-860 TO A SPLICE WITH
FEEDERS M65 AND M18 INSIDE EMH-863. PROVIDE PULL WIRE IN
VACATED CONDUIT. PROTECT THE REMAINING FEEDERS M5 AND
M18 CONDUCTORS INSIDE EMH-863 FOR FUTURE RECONNECTION.
2. REMOVE SLUICE GATE CONTROL CABLE C1 BACK TO ITS SOURCE
IN BUILDING 273.
SHEET KEYNOTES
DZ RAD WAS
12858027
E L
E C
T R
I C
T
E
D
E M
O L
I T
I O
N
P
L A
N
A
R E
A
2-ED129
EMH-587
EMH-586
EMH-585
PAD
MOUNTED
TRANSFORMER
SHORE POWER
PEDESTAL
4 14
CRANE POWER
RECEPTACLE
6 7
6 7
2 6 7
SHORE POWER
PEDESTAL TB39-3
BUILDING #829
EMH-860 13
CAISSON POWER
PEDESTAL
P1
SLUICE GATE
VALVE
CAPSTAN 33
M8
C1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
M7
D E
P A
R T
M E
T
V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
D
NORTH
PLAN
KEY PLAN
4 5
11 12
2 3
13 14
MATCH LINE
A1/2-ED135
SHEET NOTES
SHEET KEYNOTES
SCALE: 1" = 20'
PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 10
A1
PLAN
NORTH
40'10'0 20'
1. REMOVE SERVICE LATERAL CONDUCTORS TO PUMP STATION SERVICE
ENTRANCE EQUIPMENT. REFER TO SHEET 2-GD160 FOR EQUIPMENT
LOCATION.
2. REMOVE FEEDER 30 CONDUCTORS FROM DUCTBANK.
3. REMOVE SWPS-2 SERVICE TRANSFORMER. TURN TRANSFORMER TO
THE GOVERNMENT.
4. DISCONNECT AND DEMOLISH SHORE POWER PEDESTAL TB39-5.
5. DISCONNECT AND DEMOLISH CRANE POWER RECEPTACLE AND
DISCONNECT.
6. REMOVE FEEDERS 28 CONDUCTORS FROM DUCTBANK.
7. REMOVE FEEDER 29 CONDUCTORS FROM DUCTBANK.
8. DISCONNECT SLUICE GATE VALVE POWER FEEDER M8 AND CONTROL
CABLE C1. REMOVE FEEDER M8 BACK TO A SPLICE INSIDE EMH-860.
9. DISCONNECT CAISSON POWER PEDESTAL FEEDER P1. REMOVE
CONDUCTORS BACK TO A SPLICE INSIDE EMH-860.
10. REMOVE CAPSTAN 33 FEEDER M7 BACK TO EMH-860. PROVIDE PULL
WIRE IN VACATED CONDUIT.
11. REMOVE POWER FEEDER M6 FROM EMH-860 TO A SPLICE WITH FEEDERS
M65 AND M18 INSIDE EMH-863. PROVIDE PULL WIRE IN VACATED
CONDUIT. PROTECT THE REMAINING FEEDERS M5 AND M18
CONDUCTORS INSIDE EMH-863 FOR FUTURE RECONNECTION.
12. REMOVE SLUICE GATE CONTROL CABLE C1 BACK TO ITS SOURCE IN
BUILDING 273.
13. FACILITATE PARTIAL DEMOLITION OF EMH860 AND CONNECTING
PATHWAYS. REFER TO SHEETS 2-SD110 AND 2-ES503 FOR ADDITIONAL
INFORMATION.
14. DISCONNECT TB39-5 TELEPHONE CABLE AND REMOVE IT BACK TO
TB39-3.
1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.
2. REFER TO SHEET 1-E011 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
M A
T C
H
L I N
E
A E
D
DZ RAD WAS
12858028
E L
E C
T R
I C
T
E
D
E M
O L
I T
I O
N
P
L A
N
A
R E
A
2-ED130
EMH-631
EMH-S631
BUILDING 272
EMH-632
EMH-881
EMH-878
MV SWITCH G/S-4
MV SWITCH G/S-3
EMH-1490
MV SWITCH
DD8-G/S-1S
EMH-632S
TMH-1-09
EMH-1-09
MV SWITCH
DD8-G/S-1S
F2
F5 04
X
X
X
X
XXX
X0606
X0606
11 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXX
F4
F3
X
X
XXX
X
X
X
X
XXX
X0606
X0606
F1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXX
D E
P A
R T
M E
T
V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
D
NORTH
PLAN
KEY PLAN
4 5
11 12
2 3
13 14
M A
T C
H
L I N
E
A E
D
SHEET NOTES
SHEET KEYNOTES
1. DISCONNECT FEEDERS 32 FROM DISTRIBUTION VI 2.3KV BUS
INSIDE BUILDING 272.
2. REMOVE FEEDER 32 CONDUCTORS FROM DUCTBANK.
SCALE: 1" = 20'
PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 12
A1
PLAN
NORTH
40'10'0 20'
1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.
2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
MATCH LINE
A1/2-ED127
DZ RAD WAS
12858029
E L
E C
T R
I C
T
E
D
E M
O L
I T
I O
N
P
L A
N
A
R E
A
2-ED132
14'
EMH-640S
BUILDING 274
EMH-885
EXISITNG
EMH-888
EMH-640
EMH-1487
UNIT
SUBSTATIONS
REFER TO "ENLARGED PLAN - SUBSTATION
PLATFORM" ON SHEET 2-E-406
EMH-1-08
EMH-1-08A
PRIMARY UNIT
SUBSTATION DD8-S/S-1S
MV SWITCH DD8-G/S-3S
TMH-1-08
F3
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXX
F4
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXX
F4
200606 23
200606 23
200606 23
060606 06
06 06 06
20 06 06
20 06 06
20 06 06
200606 23
200606 23
200606 23
060606 06
X
X
X
X
XXX
X0606
X0606
X
X
X
X
XXX
X0606
X0606
X
X
X
X
XXX
X0606
X0606
F3
D E
P A
R T
M E
T
V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
D
NORTH
PLAN
KEY PLAN
4 5
11 12
2 3
13 14
M A
T C
H
L I N
E
A E
D
M A
T C
H
L I N
E
A E
D
SHEET NOTES
SHEET KEYNOTES
SCALE: 1" = 20'
PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 13
A1
PLAN
NORTH
40'10'0 20'
1. REMOVE FEEDER 32 CONDUCTORS FROM DUCTBANK.
1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.
2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
MATCH LINE
A1/2-ED128
DZ RAD WAS
12858030
E L
E C
T R
I C
T
E
D
E M
O L
I T
I O
N
P
L A
N
A
R E
A
2-ED133
EMH-634S
EMH-S635
EMH-635
EMH-S5
EMH-634
PUMPWELL
EMH-891
MV
SWITCH
DD8-G/S-2S
SUBSTATION Z4-E
SUBSTATION
Z4-F
EMH-892
EMH-890
EMH-893
EMH-1-07
EMH-895
EMH-896
TMH-1-07
200606 23
XX
XX
X
XX
XX
X
X
XX
XX
X XX
200606 23
200606 23
060606 06
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
F4
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXX
F4
F4
2006 23
2006 23
2006 23
0606 06
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXX
X0606
X0606
XX
X X XX
X
X
X
X
X
X
X
X
X
X
X X XX
X
X
XX
X
X
X
X
45 06
38 46
39 47
T1
T2
F4
F4
T1
T2
GENERATOR
FUEL STORAGE
SWITCHGEAR
T1
D E
P A
R T
M E
T
V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
D
KEY PLAN
4 5
11 12
2 3
13 14
MATCH LINE
A1/2-ED129
M A
T C
H
L I N
E
A E
D
M A
T C
H
L I N
E
A E
D
SHEET NOTES
SHEET KEYNOTES
SCALE: 1" = 20'
PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 14
A1
PLAN
NORTH
40'10'0 20'
1. REMOVE FEEDERS 32 CONDUCTORS FROM DUCTBANK.
1. REFER TO SHEET 1-ES603 FOR CABLE AND CONDUIT SCHEDULE.
2. REFER TO SHEET 1-E-011 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
DZ RAD WAS
12858031
E L
E C
T R
I C
T
E
D
E M
O L
I T
I O
N
P
L A
N
A
R E
A
2-ED134
T L
EMH-636
TMH-636S
MV SWITCH
EMH-913
EMH-898
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX31
1 2
BUILDING #828
D E
P A
R T
M E
T
V
Y
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V A
L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 25 AUG 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
A
N O
R F
O L
K
N
A V
I P
Y A
R D
P O
R T
S M
O U
T H
V
I R
G I N
I A
P
D
R Y
D O
C K
S A
LT
W
A
TE
R S
Y S
TE
M
FO
R
C V
N -7
JTL/TLH
EJA
DSN
1364315
N40085-22-R-2598
DLB
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
02/02/2022
I S
S U
D
SHEET NOTES
KEY PLAN
MATCH LINE
A1/2-ED130
SHEET KEYNOTES
4 5
11 12
2 3
13 14
SCALE: 1" = 20'
PHASE II - ELECTRICAL DEMOLITION PLAN - AREA 15
A1
PLAN
NORTH
40'10'0 20'
1. REMOVE FEEDER 32 CONDUCTORS FROM DUCTBANK.
2. REMOVE FEEDER 31 CONDUCTORS FROM DUCTBANK
3. REMOVE DISCONNECT AND REMOVE MV SWITCH. TURN EQUIPMENT TO THE
GOVERNMENT.
4. REMOVE SERVICE FEEDER CONDUCTORS TO PUMP STATION SERVICE
ENTRANCE EQUIPMENT. REFER TO SHEET 2-GD160 FOR EQUIPMENT
LOCATION.
1. REFER TO SHEET 2-ES603 FOR CABLE AND CONDUIT SCHEDULE.
2. REFER TO SHEET 1-E011 FOR ELECTRICAL LEGEND AND
ABBREVIATIONS.
M A
T C
H
L I N
E
A E
D
DZ RAD WAS
12858032
E L
E C
T R
I C
T
E
D
E M
O L
I T
I O
N
P
L A
N
A
R E
A
2-ED135
T
T
PS6-GENERATOR
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
C
R e v it P ro je c ts
\D R
Y D
P -1
-E
-P S ra ke m p .r v t
/2
/2
:3
:3
P
M
2-EG151
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
P U
M P
S T
A T
IO
N
LI
G
H
TI
N
IN
G P
R O
T E
C
TI
O N
A N
D G
R O
U N
D
IN
G P
LA
N
RHS
12858033
JCC RAK
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL/TLH
1364315
N40085-22-R-2598
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
JAS
DSN
3/16" = 1'-0" A3
PUMP STATION 6 - LIGHTNING PROTECTION PLAN
SHEET NOTES
1. PROVIDE A FRANKLIN ROD TYPE LIGHTNING PROTECTION SYSTEM IN
ACCORDANCE WITH NFPA780, AND UL96A. THIS IS A PERFORMANCE
BASED SYSTEM, DESIGN AND INSTALLATION MUST FOLLOW APPLICABLE
STANDARDS AND SPECIFICATIONS.
2. ALL SYSTEM MATERIALS MUST BE UL LISTED FOR LIGHTNING
PROTECTION SYSTEMS. LABEL ALL CONDUCTORS EVERY 10' WITH UL
LISTING.
3. ENSURE THAT MATERIALS USED ARE COMPATIBLE WITH THE ROOFING
SYSTEM. PROVIDE COPPER CONDUCTORS. DO NOT USED DISSIMILAR
METALS.
4. SEE ARCHITECTURAL ROOF PLAN FOR PRICING AND DESIGN PURPOSES.
5. SEE SHEET 2-EG502 FOR LIGHTNING PROTECTION DETAILS.
6. ELECTRICAL DISTRIBUTION GROUNDING MUST COMPLY WITH NEC ART.
250.
7. BOND ALL METAL HARDWARE SUCH AS LADDERS, VENT PIPING, ETC. AND
TO COORDINATE WITH ALL EXISTING STRUCTURES.
8. PATCH AND REPAIR EXISTING PAVED AREAS.
9. COMPLY WITH FAA STD-19F.
0' 4' 8' 12'
PLAN
NORTH
PLAN
NORTH
KEY PLAN
PS-6
T
T
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R C
O N
S
TR
U C
T
IO
N
/2 8/
1" = 10'-0" (2-EL151)
PUMP STATION 6 - SITE EQUIPMENT GROUNDING PLAN
SHEET NOTES
1. PROVIDE GROUND CONNECTION TO PLATFORM REBAR AND FOUNDATION
PILE.
2. PROVIDE GROUND CONNECTION TO EQUIPMENT AND ENCLOSURE.
3. PROVIDE GROUND ROD TEST WELL; SEE1-ES516/C1.
4. PROVIDE GROUND CONNECTION TO PLATFORM HANDRAIL. IF HANDRAIL IS
NOT CONTINUOUS, BOND ALL NONCONTINOUS SECTIONS TOGETHER.
0" 10' 30'20'
PLAN
NORTH
IS
SU
ED
F
OR
PS8-FOT-1 PS8-GENERATOR
T
T
2 4 3
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
C
R e v it P ro je c ts
\D R
Y D
P -1
-E
-P S ra k e m p .r v t
/2
/2
:4
:5
P
M
2-EG161
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
P U
M P
S T
A T
IO
N
LI
G
H
TN
IN
G
P R
O T
E C
TI
O
N A
N D
G R
O U
N D
IN
G
P
LA
N
RHS
12858034
JCC RAK
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL/TLH
1364315
N40085-22-R-2598
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
JAS
DSN
SHEET NOTES
1. PROVIDE A FRANKLIN ROD TYPE LIGHTNING PROTECTION SYSTEM IN
ACCORDANCE WITH NFPA780, AND UL96A. THIS IS A PERFORMANCE
BASED SYSTEM, DESIGN AND INSTALLATION MUST FOLLOW APPLICABLE
STANDARDS AND SPECIFICATIONS.
2. ALL SYSTEM MATERIALS MUST BE UL LISTED FOR LIGHTNING
PROTECTION SYSTEMS. LABEL ALL CONDUCTORS EVERY 10' WITH UL
LISTING.
3. ENSURE THAT MATERIALS USED ARE COMPATIBLE WITH THE ROOFING
SYSTEM. PROVIDE COPPER CONDUCTORS. DO NOT USED DISSIMILAR
METALS.
4. SEE ARCHITECTURAL ROOF PLAN FOR PRICING AND DESIGN PURPOSES.
5. SEE SHEET 2-EG502 FOR LIGHTNING PROTECTION DETAILS.
6. ELECTRICAL DISTRIBUTION GROUNDING MUST COMPLY WITH NEC ART.
250.
7. BOND ALL METAL HARDWARE SUCH AS LADDERS, VENT PIPING, ETC. AND
TO COORDINATE WITH ALL EXISTING STRUCTURES.
8. PATCH AND REPAIR EXISTING PAVED AREAS.
9. COMPLY WITH FAA STD-19F.
3/16" = 1'-0" A2
PUMP STATION 8 - LIGHTNING PROTECTION PLAN
0' 4' 8' 12'
PLAN
NORTH
PLAN
NORTH
KEY PLAN
PS-8
T
T
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/2
8/
1" = 10'-0" C2
PUMP STATION 8 - SITE EQUIPMENT GROUNDING PLAN
SHEET NOTES
1. PROVIDE GROUND CONNECTION TO PLATFORM REBAR AND FOUNDATION
PILE.
2. PROVIDE GROUND CONNECTION TO EQUIPMENT AND ENCLOSURE.
3. PROVIDE GROUND ROD TEST WELL; SEE1-ES516/C1.
4. PROVIDE GROUND CONNECTION TO PLATFORM HANDRAIL. IF HANDRAIL IS
NOT CONTINUOUS, BOND ALL NONCONTINOUS SECTIONS TOGETHER.
0" 10' 30'20'
PLAN
NORTH
IS
SU
ED
F
OR
NOTES:
1. THIS DETAIL DOES NOT PRECLUDE THE REQUIREMENTS OF
NEC ART. 250 OR NFPA 780. GROUNDING SYSTEM MUST
STRICTLY ADHERE TO NEC ART. 250, WHICH SUPERCEDES
THIS DETAIL.
2. BOND ALL METAL HARDWARE, SUCH AS STAIRS, LADDER,
ETC., TO THE ELECTRICAL GROUNDING SYSTEM.
N
G
MAIN GND BUS
(MGB) UPPER LEVEL
TYP OF ALL
MAJOR ELEC
EQUIPMENT
SWGR/PANEL BOARD
TYP.
ROOF LEVEL
LOWER LEVEL
TYP OF ALL
MAJOR MECH
EQUIPMENT
GENERATOR
GROUNDING COUNTERPOISEEXOTHERMIC WELD
TYP.
GROUNDING
ELECTRODE
CONDUCTOR
LIGHTNING PROTECTION DOWN
CONDUCTOR PER NFPA 780
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
C
R e v it P ro je c ts
\D R
Y D
P -1
-E
-P S ra ke m p .r v t
/2
/2
:3
:3
P
M
2-EG501
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
G R
O U
N D
IN
G
D E
T A
IL
S
RHS
12858035
JCC RAK
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL/TLH
1364315
N40085-22-R-2598
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
JAS
DSN
NOT TO SCALE
A2
TYPICAL GROUNDING RISER SCHEMATIC
SHEET NOTES
1. SEE 1-EG501 FOR ADDITIONAL GROUNDING DETAILS.
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R C
O N
S
TR
U C
T
IO
N
/2 8/
IS
SU
ED
F
OR
1.
2.
NOTES:
1. AIR TERMINALS OVER 24 INCHES
ARE SUPPORTED.
2. AIR TERMINAL SUPPORTS ARE
LOCATED AT A POINT NOT LESS
THAN ONE-HALF THE HEIGHT OF
THE AIR TERMINAL.
3'-0" MIN OFF DRIP LINE
PROVIDE MINIMUM #2 AWG GREEN INSULATED
COPPER DOWN CONDUCTOR
1" UV STABILIZED PVC CONDUIT
FOR DOWNCONDUCTORS.
MOUNT TO BUILDING
EXTERIOR WALL (TYP.)
AIR TERMINAL
ROUTE DOWN CONDUCTOR
ON OUTSIDE OF WALL
PROVIDE CLASS II MECHANICAL
CONNECTION
MAIN ROOF
CONDUCTOR
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
C
R e v it P ro je c ts
\D R
Y D
P -1
-E
-P S ra ke m p .r v t
/2
/2
:3
:3
P
M
2-EG502
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
LI
G
H
TN
IN
G
P R
O T
E C
TI
O
N D
E T
A
IL
S
RHS
12858036
JCC RAK
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL/TLH
1364315
N40085-22-R-2598
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
JAS
DSN
NOT TO SCALE
C2
AIR TERMINAL 24" OR TALLER ROOF MOUNTING DETAIL
NOT TO SCALE
C4
TYPICAL DOWN CONDUCTOR DETAIL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R C
O N
S
TR
U C
T
IO
N
/2 8/
IS
SU
ED
F
OR
ROOF TOS
136' - 0"
GRADING LEVEL
103' - 0"
SECOND LEVEL
121' - 0"
ENTRY LEVEL
109' - 0"
FIRST LEVEL
103' - 6"
C1E
PS6-1-3
C1E
PS6-1-3
8'
0" 8'
0"
C1
PS6-1-3
C1E
PS6-1-3
8'
0"
8'
0"
ROOF TOS
136' - 0"
GRADING LEVEL
103' - 0"
SECOND LEVEL
121' - 0"
ENTRY LEVEL
109' - 0"
FIRST LEVEL
103' - 6"
C1E
PS6-1-3
C1E
PS6-1-3
8'
0"
C1E
PS6-1-3
C1E
PS6-1-3
8'
0"
8'
0" 8'
0"
C1
2-EL151
A1
2-EL151
C1E C1E
A1E A1
A1 A1
A1 A1E
A1 A1
A1E A1
C2
PS6-1-3
C2
PS6-1-3
C2
PS6-1-3
C2
PS6-1-3
C1E C1E
15'-0" AFF
C2
PS6-1-3
C2
PS6-1-3
C2
PS6-1-3
C2
PS6-1-3
A1
PS6-1-2
A1
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
C
R e v it P ro je c ts
\D R
Y D
P -1
-E
-P S ra ke m p .r v t
/2
/2
:3
:4
P
M
2-EL151
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
P U
M P
S T
A T
IO
N
LI
G
H
TI
N G
P
LA
N
F
IR
S T
L E
V E
L
RHS
12858037
JCC RAK
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL/TLH
1364315
N40085-22-R-2598
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
JAS
DSN
SHEET NOTES
1. PENDANT MOUNT TYPE A2 LIGHTING FIXTURES, UON.
2. ALL OUTDOOR LIGHTING FIXTURES WILL BE CONTROLLED BY BUILDING
MOUNTED PHOTOCELL.
0' 4' 8' 12'
PLAN
NORTH
1/4" = 1'-0" C1
PUMP STATION 6 - LIGHTING ELEVATION - PLAN NORTH
1/4" = 1'-0" A1
PUMP STATION 6 - LIGHTING ELEVATION - PLAN SOUTH
2' 4' 8'0'
2' 4' 8'0'
PLAN
NORTH
KEY PLAN
PS-6
SHEET KEYNOTES
1. MOUNT FIXTURES 15'-0" ABOVE GRADING LEVEL.
2. MOUNT LIGHTING SWITCH 4'-0" ABOVE STRUCTURAL PLATFORM.
3/16" = 1'-0" (2-EL151)
A3
PUMP STATION 6 - LIGHTING PLAN - FIRST LEVEL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R C
O N
S
TR
U C
T
IO
N
/2 8/
IS
SU
ED
F
OR
C1E C1E
C1E
A1
PS6-1-1
A1E
A1 A1
A1E A1
A1 A1E
A1 A1
A1E A1
C1E
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
C
R e v it P ro je c ts
\D R
Y D
P -1
-E
-P S ra ke m p .r v t
/2
/2
:3
:4
P
M
2-EL152
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
P U
M P
S T
A T
IO
N
LI
G
H
TI
N G
P
LA
N
S E
C O
N D
L E
V E
L
RHS
12858038
JCC RAK
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL/TLH
1364315
N40085-22-R-2598
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
JAS
DSN
SHEET NOTES
1. PENDANT MOUNT TYPE A1 LIGHTING FIXTURES, UON.
2. ALL OUTDOOR LIGHTING FIXTURES WILL BE CONTROLLED BY BUILDING
MOUNTED PHOTOCELL.
0' 4' 8' 12'
PLAN
NORTH
PLAN
NORTH
KEY PLAN
PS-6
SHEET KEYNOTES
1. PROVIDE PHOTOCELL FOR CONTROL OF OUTDOOR LIGHTING FIXTURES.
3/16" = 1'-0" A2
PUMP STATION 6 - LIGHTING PLAN - SECOND LEVEL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R C
O N
S
TR
U C
T
IO
N
/2 8/
IS
SU
ED
F
OR
FIRST LEVEL
103' - 6"
ROOF/T.O.S.
136' - 0"
GRADING LEVEL
103' - 0"
SECOND LEVEL
121' - 0"
ENTRY LEVEL
109' - 0"
ROOF/T.O.S.
136' - 0"
SECOND LEVEL
121' - 0"
GRADING LEVEL
103' - 0"
C1E
PS8-1-8
C1E
PS8-1-8
8'
0" 8'
0"
C1E
PS8-1-8
8'
0" 8'
0"
C1E
PS8-1-8
FIRST LEVEL
103' - 6"
ROOF/T.O.S.
136' - 0"
GRADING LEVEL
103' - 0"
SECOND LEVEL
121' - 0"
ENTRY LEVEL
109' - 0"
ROOF/T.O.S.
136' - 0"
SECOND LEVEL
121' - 0"
GRADING LEVEL
103' - 0"
SECOND LEVEL
121' - 0"
C1E
PS8-1-8
8'
0" 8'
0"
C1E
PS8-1-8
C1E
PS8-1-8
8'
0" 8'
0"
C1E
PS8-1-8
B1
2-EL161
B3
2-EL161
C1E C1E
C2
PS8-1-8
C2
PS8-1-8
C2
PS8-1-8
C2
PS8-1-8
A1 A1E A1 A1 A1E
A1 A1 A1E A1 A1
1 1 1 1
2 2
C1E C1E
15'-0" AFF
C2
PS8-1-8
C2
PS8-1-8
C2
PS8-1-8
C2
PS8-1-81 1 1 1
A1
PS8-1-7
A1E
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
C
R e v it P ro je c ts
\D R
Y D
P -1
-E
-P S ra k e m p .r v t
/2
/2
:4
:5
P
M
2-EL161
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
P U
M P
S T
A T
IO
N
LI
G
H
TI
N G
P
LA
N
F
IR
S T
L E
V E
L
RHS
12858039
JCC RAK
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL/TLH
1364315
N40085-22-R-2598
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
JAS
DSN
SHEET NOTES
1. PENDANT MOUNT TYPE A2 LIGHTING FIXTURE, UON.
2. ALL OUTDOOR LIGHTING FIXTURES WILL BE CONTROLLED BY BUILDING
MOUNTED PHOTOCELL.
0' 4' 8' 12'
PLAN
NORTH
1/4" = 1'-0" B1
PUMP STATION 8 - LIGHTING ELEVATION - PLAN WEST
1/4" = 1'-0"
B3
PUMP STATION 8 - LIGHTING ELEVATION - PLAN EAST
0' 4' 8' 12'0' 4' 8' 12'
PLAN
NORTH
KEY PLAN
PS-8
SHEET KEYNOTES
1. MOUNT FIXTURES 15'-0" ABOVE GRADING LEVEL.
2. MOUNT LIGHTING SWITCH 4'-0" ABOVE STRUCTURAL PLATFORM.
3/16" = 1'-0" A2
PUMP STATION 8 - LIGHTING PLAN - FIRST LEVEL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/2
8/
IS
SU
ED
F
OR
3 3
C1E C1E
A1
PS8-1-9
A1 A1E A1 A1 A1E
A1A1A1EA1A1A1E
12'-0" AFF
C1EC1E
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
C
R e v it P ro je c ts
\D R
Y D
P -1
-E
-P S ra k e m p .r v t
/2
/2
:4
:5
P
M
2-EL162
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
P U
M P
S T
A T
IO
N
LI
G
H
TI
N G
P
LA
N
S E
C O
N D
L E
V E
L
RHS
12858040
JCC RAK
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL/TLH
1364315
N40085-22-R-2598
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
JAS
DSN
SHEET NOTES
1. PENDANT MOUNT TYPE A1 LIGHTING FIXTURE, UON.
2. ALL OUTDOOR LIGHTING FIXTURES WILL BE CONTROLLED BY BUILDING
MOUNTED PHOTOCELL.
0' 4' 8' 12'
PLAN
NORTH
PLAN
NORTH
KEY PLAN
PS-8
3/16" = 1'-0"
A2
PUMP STATION 8 - LIGHTING PLAN - SECOND LEVEL
SHEET KEYNOTES
1. PROVIDE PHOTOCELL FOR CONTROL OF OUTDOOR LIGHTING FIXTURES.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/2
8/
IS
SU
ED
F
OR
REVISED: SEPTEMBER 2020 TYPE: A1LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
HOUSING - LOW PROFILE, ONE-PIECE, FIBERGLASS HOUSING WITH INTEGRAL
PERIMETER CHANNEL.
LENS - INJECTION MOLDED, HIGH IMPACT-RESISTANCE ACRYLIC LENS.
LIGHT SOURCE - HIGH-EFFICIENCY LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
3500K CCT UON, MINIMUM 80 CRI.
MOUNTING - SURFACE, WALL.6.
5.
4.
3.
2.
1.
7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE
A CERTAIN MANU FACTURER OR PREFERENCE.
CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80, AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED
WITH EMERGENCY BATTERY BACK-UP.
DRIVER - INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF, OPERATING
VOLTAGE OF 120-277V, THERMAL MANAGEMENT, <20% TOTAL HARMONIC DISTORTION.
ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
LED ENCLOSED AND GASKETED
4' NOMINAL
4 0.69
RCR
1.03
0.78 0.89
CU
NOMINAL 25W INPUT/
4000 LUMENS
TYPE A1
LPW - 160
MINIMUM
LED WALL PACK
REVISED: JANUARY 2014 TYPE: C1, C2LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
HOUSING - STAINLESS STEEL EXTRUDED HOUSING AND MILLED ENDCAPS.
FINISH - ELECTROSTATICALLY APPLIED POWDER COATED FINISH.
LENS - 100% ACRYLIC, FROSTED
ELECTRONIC DRIVER - IES LM-80 PERFORMANCE FOR 60,000
HOURS MINIMUM. SOUND RATING "A" WITH LESS THAN 20% THD, MINIMUM 0.9 POWER
FACTOR, INHERENT THERMAL PROTECTION, SHORT-CIRCUIT AND OVERLOAD
PROTECTION, AND COMPLIES WITH ANSI C62.41 CATEGORY A TRANSIENT PROTECTION.
PROVIDE 0-10V DIMMING DRIVER FOR 5-100% DIMMING RANGE OR BI-LEVEL STEP-
DIMMING IF INDICATED. PROVIDE WITH EMERGENCY BATTERY DRIVER.
CERTIFICATION - UL LISTED AND LABELED, DAMP LOCATION
6.
5.
4.
3.
2.
1.
MOUNTING - LUMINAIRE MUST HAVE A "FLANGLESS" AND FLUSH
APPEARENCE WHEN MOUNTED IN GYPSUM HARD CEILING OR WALL.
7. OPTICS - LUMINAIRE MUST PROVIDE A SYMMETRICAL DISTRIBUTION
PATTERN.
PHOTOMETRICS - MINIMUM VALUE OF COEFFICIENT OF
UTILIZATION (CU), GIVEN INTERIOR CAVITY REFLECTANCES OF
80-50-20:
8.
RCR CU
NOMINAL 25W INPUT/
4000 LUMENS
TYPE C1
LPW - 160
MINIMUM
0.84
1.10 1.01
0.92
RCR CU
NOMINAL 54W INPUT/
8000 LUMENS
TYPE C2
LPW - 150
MINIMUM
0.84
1.10 1.01
0.92
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
C
R e v it P ro je c ts
\D R
Y D
P -1
-E
-P S ra ke m p .r v t
/2
/2
:3
:4
P
M
2-EL501
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
LI
G
H
TI
N G
S C
H E
D U
LE
S
A N
D D
E
TA
IL
S
RHS
12858041
JCC RAK
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL/TLH
1364315
N40085-22-R-2598
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
JAS
DSN
LIGHT FIXTURES SCHEDULE
FIXTURE LAMP INFORMATION FIXTURE INFORMATION
TYPE TYPE COLOR TEMP
FIXTURE
LUMENS VOLTAGE WATTAGE DESCRIPTION MOUNTING
A1 LED 3500 K 4000 lm 277 V 25 W 4' ENCLOSED & GASKETED LED LUMINAIRE WITH SHALLOW ACRYLIC LINEAL
RIBBED FROSTED LENS
CEILING, SURFACE, PENDANT
C1 LED 3500 K 4000 lm 277 V 24 W EXTERIOR EGRESS WALLPACK. PROVIDE WITH EMERGENCY BATTERY
DRIVER.
WALL, SURFACE
C2 LED 3500 K 8000 lm 277 V 54 W EXTERIOR WALLPACK WALL, SURFACE, 14'-6" ABOVE GRADE, UON
LIGHTING CONTROL SCHEDULE
NAME CONTROLS
PUMP STATION 6 - SECOND LEVEL SW
PUMP STATION 6 - SUMP LEVEL SW
PUMP STATION 8 - SECOND LEVEL SW
PUMP STATION 8 - SUMP LEVEL SW
LIGHTING SEQUENCE OF OPERATIONS:
1. SPACES INDICATED WITH "SW" MUST HAVE THE FOLLOWING
FEATURES AND FUNCTIONS:
A. STANDARD LOCAL SNAP SWITCH FOR COMPLETE
MANUAL ON-OFF CONTROLL BY THE USER
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
IS
S U
E D
F O
R C
O N
S
TR
U C
T
IO
N
/2 8/
IS
SU
ED
F
OR
M
M
M
M
M
M
M
M
M
M M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
WPIU
GFI
WPIU
GFI
WPIU
GFI
WPIU
GFI
WPIU
GFI
FACP
PS6-SP-1
PS6-SP-2
PS6-P-3
PS6-P-2
PS6-P-1
PS6-DSS-CU-1
PS6-DSS-CU-2
PS6-DSS-CU-3
PS6-DSS-CU-4
PS6-3-12,14
PS6-3-13,15
PS6-3-8,10
PS6-DSS-2
PS6-DSS-3
D30
D30
D301
PS6-2-5
PS6-MONORAIL
RT
PS6-3-3
PS6-3-3
PS6-3-6
PS6-3-7
PS6-2-5
PS6-2-5
PS6-ACT-4
PS6-ACT-8
PS6-ACT-12
PS6-3-4
PS6-ACT-18
PS6-3-4
PS6-1-22,24,26
PS6-1-28,30,32
PS6-1-25,27,29
PS6-1-16,18,20
PS6-3-…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .