1364315_dwg_08of18_PH1_V2_Fire Protection.pdf
PDF 1 MB Posted
- Attached to
- P-678 Dry Dock 8 Saltwater System for CVN-78, Norfolk Naval Shipyard, Portsmouth, Virginia
- Solicitation number
- N40085-22-R-2598_Drawings
About this file
This document package includes construction drawings and specifications for a federal solicitation seeking fire protection system upgrades at a naval shipyard. The solicitation, number N40085-22-R-2598, is for upgrades to the saltwater system and fire alarm infrastructure for Dry Dock 8 at Norfolk Naval Shipyard in Portsmouth, Virginia. Offerors are directed to separate notices for access to the detailed drawings and specifications. The drawings depict the existing pumpwell structure and layouts for the proposed fire alarm system at multiple levels, along with details of devices, panels, and wiring. Specifications include notes outlining requirements for equipment, installation, inspections, warranties, and as-built drawings. The work involves installation and integration of a new addressable fire alarm system with controls, detectors, strobes, horns, wiring and panels to replace existing non-addressable systems.
The soliciting agency is the Naval Facilities Engineering Command within the Department of the Navy. The opportunity type is listed as a Special Notice rather than a standard solicitation. No pricing, response dates or other procurement terms are included in the document package itself.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Mechanical | Electrical | Plumbing | Fire Protection 4456 Corporation Ln, Ste 320 Tel: (757) 502-8882
Virginia Beach, Virginia 23462 Fax: (757) 499-1757
ADVANCED
ENGINEERING
CONSULTANTS
SECTION, DETAIL OR ELEVATION
IDENTIFICATION MARK
PLATE NUMBER WHERE SECTION,
DETAIL OR ELEVATION IS TAKEN
SECTION, DETAIL OR ELEVATION TITLE
PLATE NUMBER WHERE
DETAIL IS DRAWN
DETAIL NUMBER
DETAIL CALLOUT SYMBOL
SECTION CUT SYMBOL
SECTION LETTER
PLATE NUMBER WHERE
SECTION IS DRAWN
VIEW SECTION
DETAIL/SECTION TITLE
XX
X-XXX
XX
X-XXX
XX
X-XXX
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
DSN
N40085-22-R-2598
C U s e rs
\E ri n C
\D o c u m e n ts
\D R
Y D
P
-1
-F
-D R
Y D
E ri n C
V
E R
.r v t
/2
/2
:5
:5
A
M
1-FA001
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
F
IR
E A
LA
R
M G
E N
E R
A L
S H
E E
T
AEC
12857653
PJB EBC
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL / TLH
1364315
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
DSN
FIRE PROTECTION ABBREVIATIONS
AFF ABOVE FINSHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AWG AMERICAN WIRE GAUGE
CD CANDELA
dBA DECIBEL A-WEIGHTED
EMT ELECTRICAL METALLIC TUBE
EOLR END OF LINE RESISTOR
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FM FACTORY MUTUAL
IDC INITIATING DEVICE CIRCUIT
NAC NOTIFICATION APPLIANCE CIRCUIT
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NICET NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING
TECHNOLOGIES
NTS NOT TO SCALE
SLC SIGNALING LINE CIRCUIT
SPD SURGE PROTECTION DEVICE
THHN THERMOPLASTIC HIGH HEAT-RESISTANT NYLON-COATED
TYP. TYPICAL
UFC UNITED FACILITIES GUIDE
UL UNDERWRITERS LABORATORIES
V VOLTS
WP WEATHER AND DIRECT HOSE STREAM PROOF (NEMA 4)
FIRE ALARM SYMBOLS
S
FACP
R
MANUAL PULL STATION (48" TO HANDLE OF DEVICE)
SMOKE DETECTOR
RELAY FOR CONNECTION WITH MECHANICAL CONTROLS AND
DEVICES
FIRE ALARM CONTROL PANEL
HORN (80" AFF TO BOTTOM OF DEVICE)
HORN WITH STROBE (80" AFF TO BOTTOM OF DEVICE)
XXcd, WHEN USED, INDICATE THE CANDELA RATING OF DEVICE
STROBE (80" AFF TO BOTTOM OF DEVICE)
XXcd, WHEN USED, INDICATE THE CANDELA RATING OF DEVICE
RADIO TRANSCEIVER
MONITOR MODULE
RT
MM
EOL END OF LINE RESISTOR
XXcd
XXcd
ADDRESSIBLE OUTPUT MODULEAOM
F
F H
GENERAL FIRE ALARM NOTES
1. THIS SYSTEM SHALL BE AN ANALOG/ADDRESSABLE FIRE ALARM SYSTEM.
2. THE FIRE ALARM DRAWINGS ARE SCHEMATIC IN NATURE AND SHOW A
MINIMAL QUANTITY OF DEVICES. CONTRACTOR SHALL DETERMINE THE FINAL
QUANTITY AND LOCATION OF ALL DEVICES IN ACCORDANCE WITH THE
SPECIFICATIONS, CONTRACT DRAWINGS, AND MANUFACTURER'S WRITTEN
RECOMMENDATIONS TO BE COMPLIANT WITH ALL APPLICABLE CODES AND
STANDARDS. ADDITIONAL DEVICES SHALL BE PROVIDED FOR A FULLY
FUNCTIONING FIRE ALARM SYSTEM AS REQUIRED BY NFPA 72, UFC 3-600-01.
3. SIGNALING LINE, NOTIFICATION APPLIANCE, AND INITIATING DEVICE
CIRCUITS SHALL BE CLASS B.
4. ALL EXPOSED FIRE ALARM CONDUITS AND JUNCTION BOXES IN UNFINISHED
AREAS SHALL BE PAINTED RED OR PRE-FINISHED RED FROM THE FACTORY.
CONDUIT AND JUNCTION BOXES EXPOSED IN FINISHED AREAS SHALL BE
FINISHED TO MATCH ADJACENT FINISHES. ALL JUCNTION BOXES SHALL HAVE
A PERMANENT, MACHINE PRINTED LABEL STATING "FIRE ALARM CIRCUIT" ON
THE INSIDE COVER.
5. ALL SYSTEM POWER AND GROUND CIRCUITS SHALL BE TYPE THHN SOLID
COPPER SIZED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS
AND THE APPLICABLE CODES AND BE INSTALLED IN EMT CONDUIT.
6. ALL WIRING, CABLES, BOXES, THROUGHS, AND OTHER RELATED EQUIPMENT
SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE.
7. CONDUCTORS SHALL BE RUN FROM DEVICE TO DEVICE WITHOUT SPLICES.
WIRE NUTS SHALL BE PROHIBITED. TERMINAL STRIPS BE UTILIZED WHERE
CONDUCTORS CANNOT BE DIRECTLY SHALL TERMINATED AT THE DEVICE
(E.G. PIGTAILS OFF A HEAT DETECTOR).
8. FIRE ALARM EQUIPMENT PANELS SHALL NOT BE USED AS RACEWAY FOR
ROUTING POWER WIRING OR LOW VOLTAGE WIRING. ONLY WIRING
TERMINATING WITH THE PANEL SHALL BE ROUTED INTO THE PANEL. POWER
WIRING AND POWER LIMITED WIRING SHALL BE SEPARATED BY A MINIMUM
OF TWO INCHES.
9. ALL DEVICES MUST BE UL LISTED AND NEMA 4 RATED.
10. ALL POWER SUPPLIES TO FACP AND TRANSMITTERS SHALL BE PROVIDED
WITH SPD. ALL SLC, NAC, OR IDC ENTERING OR LEAVING THE BUILDING
SHALL BE PROVIDED WITH SPD. EXCEPTION: CIRCUITS TO DEVICES
MOUNTED DIRECTLY ON THE EXTERIOR OF THE BUILDING.
11. HORNS AND STROBES PROVIDED AT THE SAME LOCATION MAY BE A SINGLE
UNIT.
12. SOUND PRESSURE LEVEL FROM AUDIBLE ALARM APPIANCES SHALL NOT
EXCEED 110 dBA IN ANY OCCUPIED AREA.
13. NO FABRICATION OR INSTALLATION OF FIRE ALARM SYSTEM IS ALLOWED
WITHOUT APPROVED SHOP DRAWING SUBMITTALS.
14. PROVIDE ALL HORNS WITHIN NOTIFICATION DEVICES FOR THE PUMPWELL
AND ENTRY WALKWAY AS LOW FREQUENCY (520 HERTZ) DEVICES.
GENERAL FIRE PROTECTION NOTES
1. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO
SHOW THE EXACT LOCATIONS OF COMPONENTS, NOR SHOW ALL SYSTEM
COMPONENTS. CONTRACTOR MUST PROVIDE ADDITIONAL OFFSETS OR
FITTINGS REQUIRED FOR PROPER INSTALLATION, COORDINATION WITH OTHER
TRADES, AND/OR TO MAINTAIN PROPER CLEARANCES.
2. DRAWINGS ARE NOT TO BE SCALED. DIMENSIONS MUST GOVERN. CONTRACTOR
MUST VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE CONCERNING
NEW WORK BEFORE PROCEEDING WITH INSTALLATION IN AREAS WITH
NUMEROUS OBSTRUCTIONS INCLUDING STRUCTURE, EQUIPMENT, AND PIPING.
THIS WILL REQUIRE ON SITE CUTTING AND VERIFICATION.
3. ANY INFORMATION CONFLICTS BETWEEN THE SPECIFICATIONS AND DRAWINGS
MUST BE BROUGHT TO ENGINEER'S AND CONTRACTING OFFICER'S ATTENTION.
THE CONTRACTOR(S) MUST NOT PROCEED WITH ANY WORK, EXCEPT AT THEIR
OWN RISK, UNTIL CLARIFICATIONS OF THE CONFLICTS ARE ISSUED TO THE
CONTRACTOR(S) BY THE CONTRACTING OFFICER.
4. NO ASBESTOS CONTAINING MATERIALS MUST BE USED ON THIS PROJECT.
5. THE TERM "PROVIDE" MUST MEAN THE CONTRACTOR MUST FURNISH, INSTALL,
AND CONNECT FOR A COMPLETE AND OPERATIONAL SYSTEM.
6. ALL WORK MUST COMPLY IN ALL RESPECTS WITH THE REQUIREMENTS OF
THESE BID DOCUMENTS.
7. ALL MATERIAL AND LABOR MUST BE UNDER WARRANTY FOR ONE YEAR FROM
THE DATE OF FINAL ACCEPTANCE BY THE CONTRACTING OFFICER. ANY
DEVICES OR EQUIPMENT FOUND FAULTY MUST BE REPLACED AS PART OF THE
WARRANTY,
8. A SET OF APPROVED DRAWINGS FOR EACH SYSTEM MUST BE MAINTAINED ON
SITE AND ALL FIELD CHANGES MUST BE RED LINED ON THE DRAWINGS.
CONTRACTOR MUST PREPARE "AS-BUILT" DRAWINGS IN ELECTRONIC
(AUTOCAD) FORMAT, REFLECTING ACCURATE FIELD CONDITIONS.
9. ALL OPENING OR DAMAGE TO WALLS OR FLOORS FROM PENETRATIONS,
REMOVALS, INSTALLATIONS, OR OTHER ACTIONS OF THE CONTRACTOR MUST
BE PATCHED, REPAIRED, AND PAINTED WITH MATERIALS BY THE CONTRACTOR
TO MATCH ADJACENT WORK, WHETHER SPECIFICALLY NOTED OR NOT. REPAIRS
ARE AT THE CONTRACTORS EXPENSE.
10. PIPING AND OTHER ELEMENTS MUST NOT BE UTILIZED AS LADDERS,
SCAFFOLDING OR WORK PLATFORMS.
11. NO STRUCTURAL MEMBERS MUST BE CUT, DRILLED, OR BURNED WITHOUT THE
KNOWLEDGE AND WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER AND
THE CONTRACTING OFFICER.
FACP FUNCTIONAL MATRIX - PUMPWELL
ALARM CONDITIONS A
C
T
IV
A T
E V
IS
U
A L
"F
IR
E
S T
R O
B E
S
A C
T
IV
A T
E N
O T
IF
IC
A T
IO
N
D E
V
IC
E O
N E
X T
E R
IO
R
O F
B U
IL
D
IN
G
A C
T
IV
A T
E A
U D
IB
LE
F
IR
E A
LA
R
M E
V A
C U
A T
IO
N
A
LA
R M
C O
N D
T
IO
N A
T F
A C
P
S U
P E
R V
IS
O
R Y
C O
N D
IT
IO
N A
T F
A C
P
T R
O U
B
LE
C O
N D
IT
IO
N A
T F
A C
P
T R
A N
S M
IT
A
LA
R
M S
IG
N
A L
T O
F
IR
E D
E P
T . V
IA
T
R A
N S
M
IT
T E
R
T R
A N
S M
IT
S
U P
E R
V
IS
O R
Y S
IG
N
A L
T O
F
IR
E D
E P
T . V
IA
T
R A
N S
M
IT
T E
R
T R
A N
S M
IT
T
R O
U B
LE
S
IG
N
A L
T O
F
IR
E D
E P
T . V
IA
T
R A
N S
M
IT
T E
R
S H
U T
D O
W N
A H
U
ALARM CONDITIONS
AREA SMOKE DETECTOR ACTIVATION • • • • •
DUCT SMOKE DETECTOR • • • • • •
MANUAL PULL STATION • • • • •
SUPERVISORY CONDITIONS
COMPONENT COMMON SUPERVISORY • •
TROUBLE CONDITIONS
AC POWER FAILURE • •
COMPONENT COMMON TROUBLE • •
GROUND FAULT • •
LOW BATTERY • •
NOTIFICATION APPLICANCE CIRCUIT SHORT • •
OPEN CIRCUIT FAULT • •
OTHER TROUBLE CONDITION • •
FIRE ALARM ANNUNCIATOR PANELFAA
S Y
M D
E S
C R
IP
T
I O N
D A
T E
A P
P R
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/2
8/
IS
SU
ED
F
OR
B
ID
Virginia Beach, Virginia 23462 Fax: (757) 499-1757
ADVANCED
ENGINEERING
CONSULTANTS
MOTOR LEVEL
SEE SHEET 1-FA102
INTERMEDIATE LEVEL
SEE SHEET 1-FA103
MAIN PUMP LEVEL
SEE SHEET 1-FA104
PW8-DRAINAGE PUMP
-74' - 8 3/4"
SUCTION CHAMBER
-70' - 8 3/4"
PW8-MAIN PUMP
-57' - 0"
PW8-INTERMEDIATE
-35' - 0"
PW8-MOTOR
-20' - 0"
BOT PUMPWELL HALL
-15' - 0"
TOP PUMPWELL HALL
-6' - 0"
PW-MDP-2 PW-MDP-3 PW-MDP-4
PW-MDP-2
MOTOR
PW-MDP-3
MOTOR
PW-MDP-4
MOTOR
PW1 6
PW8-DP-5 (PW8-
DP-4 LOCATED
BEHIND PUMP)
PW8-DP-2 (PW8-DP-1
LOCATED BEHIND)
(E) DP-3
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
DSN
N40085-22-R-2598
C U s e rs
\E ri n C
\D o c u m e n ts
\D R
Y D
P
-1
-F
-D R
Y D
E ri n C
V
E R
.r v t
/2
/2
:5
:5
A
M
1-FA100
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
P U
M P
W E
LL
F
IR
E
A
LA
R M
K
E Y
P
LA
N
AEC
12857654
PJB EBC
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL / TLH
1364315
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
DSN
SHEET NOTES
1/8" = 1'-0" A1
KEY ELEVATION - PUMPWELL 8 FIRE ALARM
1 REFER TO SHEET 1-FA001 FOR LEGEND, SYMBOLS AND ABBREVIATIONS.
2 CANDELA RATINGS INDICATED ON THE DRAWINGS ARE THE MINIMUM
RATING BASED ON LAYOUT. CONTRACTOR'S NICET DESIGNER CAN
PROVIDE ALTERNATE SPACING AND INTENSITY LAYOUTS BASED ON
DEVICES FROM THEIR AVAILABLE SUPPLIER.
KEY PLAN
MOTOR
83'-0"
INTERMED.
68'-0"
MAIN PUMP
46'-0"
DRAINAGE
28'-3 1/4"
COPING
103'-0"
SUC. CHAM.
32'-3"4' 8' 16'0'
S Y
M D
E S
C R
IP
T
I O N
D A
T E
A P
P R
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/2
8/
IS
SU
ED
F
OR
Virginia Beach, Virginia 23462 Fax: (757) 499-1757
ADVANCED
ENGINEERING
CONSULTANTS
S
F
15 CD, WP
15 CD, WP
34 CD
34 CD
34 CD
34 CD
15 CD
F A
C P
1RT
MDP-2 MDP-3 MDP-4
S D
F A
A
CONTROL RM.
D S
C
34 CD
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
DSN
N40085-22-R-2598
C U s e rs
\E ri n C
\D o c u m e n ts
\D R
Y D
P
-1
-F
-D R
Y D
E ri n C
V
E R
.r v t
/2
/2
:5
:0
A
M
1-FA102
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
P U
M P
W E
LL
F
IR
E A
LA
R
M P
LA
N
M
O
TO
R
AEC
12857655
PJB EBC
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL / TLH
1364315
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
DSN
SHEET NOTES
SHEET KEYNOTES#
1/8" = 1'-0" C1
PUMPWELL - FIRE ALARM PLAN - MOTOR LEVEL
1 FIRE ALARM CONTROL PANEL, BOTTOM OF DISPLAY READOUT NO MORE
THAN 5'-0" ABOVE FINISHED FLOOR
2 PROVIDE STOBE DEVICE WITHIN EXISTING TOLET/SHOWER ROOM.
3 CONNECT FIRE ALARM SYSTEM INTO EXISTING DUCT SMOKE DECTECTOR.
PROVIDE ANY MODULES NECESSARY TO MAKE THIS CONNECTION.
4 MOUNT AN ANTENNA FOR THE RADIO TRANSCEIVER ON THE ENTRY SHED
FOR THE PUMPWELL. ROUTE WIRING THROUGH ENTRY CORRIDOR AND TO
RECEIVER ON CONTROL ROOM WALL.
1 REFER TO SHEET 1-FA001 FOR LEGEND, SYMBOLS AND ABBREVIATIONS.
2 CANDELA RATINGS INDICATED ON THE DRAWINGS ARE THE MINIMUM
RATING BASED ON LAYOUT. CONTRACTOR'S NICET DESIGNER CAN
PROVIDE ALTERNATE SPACING AND INTENSITY LAYOUTS BASED ON
DEVICES FROM THEIR AVAILABLE SUPPLIER.
KEY PLAN
MOTOR
83'-0"
INTERMED.
68'-0"
MAIN PUMP
46'-0"
DRAINAGE
28'-3 1/4"
COPING
103'-0"
SUC. CHAM.
32'-3"
PLAN
NORTH
4' 8' 16'0'
S Y
M D
E S
C R
IP
T
I O N
D A
T E
A P
P R
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/2
8/
IS
SU
ED
F
OR
Virginia Beach, Virginia 23462 Fax: (757) 499-1757
ADVANCED
ENGINEERING
CONSULTANTS
34 CD
34 CD34 CD34 CD34 CD
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
DSN
N40085-22-R-2598
C U s e rs
\E ri n C
\D o c u m e n ts
\D R
Y D
P
-1
-F
-D R
Y D
E ri n C
V
E R
.r v t
/2
/2
:5
:0
A
M
1-FA103
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
P U
M P
W E
LL
F
IR
E A
LA
R
M P
LA
N
IN
TE
R
M E
D
IA
TE
AEC
12857656
PJB EBC
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL / TLH
1364315
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
DSN
SHEET NOTES
1/8" = 1'-0" C1
PUMPWELL - FIRE ALARM PLAN - INTERMEDIATE LEVEL
1 REFER TO SHEET 1-FA001 FOR LEGEND, SYMBOLS AND ABBREVIATIONS.
2 CANDELA RATINGS INDICATED ON THE DRAWINGS ARE THE MINIMUM
RATING BASED ON LAYOUT. CONTRACTOR'S NICET DESIGNER CAN
PROVIDE ALTERNATE SPACING AND INTENSITY LAYOUTS BASED ON
DEVICES FROM THEIR AVAILABLE SUPPLIER.
KEY PLAN
MOTOR
83'-0"
INTERMED.
68'-0"
MAIN PUMP
46'-0"
DRAINAGE
28'-3 1/4"
COPING
103'-0"
SUC. CHAM.
32'-3"
PLAN
NORTH
4' 8' 16'0'
S Y
M D
E S
C R
IP
T
I O N
D A
T E
A P
P R
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/2
8/
IS
SU
ED
F
OR
Virginia Beach, Virginia 23462 Fax: (757) 499-1757
ADVANCED
ENGINEERING
CONSULTANTS
34 CD34 CD34 CD
75 CD
MDP-2 MDP-3 MDP-4
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
DSN
N40085-22-R-2598
C U s e rs
\E ri n C
\D o c u m e n ts
\D R
Y D
P
-1
-F
-D R
Y D
E ri n C
V
E R
.r v t
/2
/2
:5
:0
A
M
1-FA104
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
P U
M P
W E
LL
F
IR
E A
LA
R
M P
LA
N
M
A
IN
P U
M P
AEC
12857657
PJB EBC
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL / TLH
1364315
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
DSN
SHEET NOTES
SHEET KEYNOTES#
1/8" = 1'-0" C1
PUMPWELL - FIRE ALARM PLAN - MAIN PUMP LEVEL
1 REFER TO SHEET 1-FA001 FOR LEGEND, SYMBOLS AND ABBREVIATIONS.
2 CANDELA RATINGS INDICATED ON THE DRAWINGS ARE THE MINIMUM
RATING BASED ON LAYOUT. CONTRACTOR'S NICET DESIGNER CAN
PROVIDE ALTERNATE SPACING AND INTENSITY LAYOUTS BASED ON
DEVICES FROM THEIR AVAILABLE SUPPLIER.
KEY PLAN
MOTOR
83'-0"
INTERMED.
68'-0"
MAIN PUMP
46'-0"
DRAINAGE
28'-3 1/4"
COPING
103'-0"
SUC. CHAM.
32'-3"
PLAN
NORTH
4' 8' 16'0'
1 HORN/STOBE TO BE MOUNTED 6'-8" ABOVE CATWALK WITHIN THIS
CHAMBER.
S Y
M D
E S
C R
IP
T
I O N
D A
T E
A P
P R
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/2
8/
IS
SU
ED
F
OR
Virginia Beach, Virginia 23462 Fax: (757) 499-1757
ADVANCED
ENGINEERING
CONSULTANTS
RADIO TRANSCEIVER
TO TRANSMIT SIGNAL
TO BASE WIDE
SYSTEM
FACP
BATTERY CABINET
FINISHED FLOOR
5' -0
F
R O
M F
LO
O
R T
O D
IS
P
LA
Y
P A
N E
L O
N F
A C
P
CORNER OF CONTROL ROOM
F
FACP
S
RT
EOL
WP
POWER FOR FACP FROM PANEL PW8-4,
CIRCUIT 20 AND RADIO TRANSCEIVER FROM
PANEL PW-8-4, CIRCUIT 1, REFER TO SHEET
1-EP101
CONNECT TO EXISTING BASE FA
SYSTEM VIA SIGNAL FROM
ANTENNA, WHICH IS TO BE
INSTALLED ON PUMPWELL ENTRY
SHED.
PROVIDE 120VAC SURGE SUPPRESSION
DEVICES FOR EACH UNIT.
S D
NOTE: NOT ALL DEVICES ARE INDICATED ON RISER DIAGRAM
FAA
FAA POWERED FROM FACP
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K
V A
AS NOTED
F
IL
E N
A M
E
P
LO
T T
E D
DSN
N40085-22-R-2598
C U s e rs
\E ri n C
\D o c u m e n ts
\D R
Y D
P
-1
-F
-D R
Y D
E ri n C
V
E R
.r v t
/2
/2
:5
:0
A
M
1-FA501
P D
R Y
D O
C K
S
A L T
W A
T E
R S
Y S
T E
M
F O
R C
V N
-7
F
IR
E A
LA
R
M D
E
TA
IL
S
AEC
12857658
PJB EBC
02/02/2022
DEVIN POULIN,
C984 FACILITIES PLANNER, NNSY
JTL / TLH
1364315
P O
R T
S M
O U
T H
, V
IR
G
IN
IA
N
O R
F O
LK
N
A V
A L
S H
IP
Y
A R
D
EJA
DSN
NOT TO SCALE
A4
FIRE ALARM CONTROL PANEL DETAIL
NOT TO SCALE
C4
FIRE ALARM RISER DIAGRAM
S Y
M D
E S
C R
IP
T
I O N
D A
T E
A P
P R
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/2
8/
IS
SU
ED
F
OR
| 1-FA001 - FIRE ALARM GENERAL SHEET |
| 1-FA100 - PUMPWELL 8 - FIRE ALARM - KEY PLAN |
| 1-FA102 - PUMPWELL - FIRE ALARM PLAN - MOTOR |
| 1-FA103 - PUMPWELL - FIRE ALARM PLAN - INTERMEDIATE |
| 1-FA104 - PUMPWELL - FIRE ALARM PLAN - MAIN PUMP |
| 1-FA501 - FIRE ALARM DETAILS |
2022-02-25T10:34:40-0500
2022-02-25T10:34:51-0500
2022-02-25T10:34:51-0500
2022-02-25T10:34:51-0500
2022-02-25T10:34:51-0500
2022-02-25T10:34:51-0500
2022-02-25T10:35:04-0500
2022-02-25T10:35:14-0500
2022-02-25T10:35:14-0500
2022-02-25T10:35:14-0500
2022-02-25T10:35:14-0500
2022-02-25T10:35:14-0500
| 2022-03-15T21:12:23-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:12:35-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:12:37-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:12:40-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:12:41-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:12:44-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:13:00-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:13:14-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:13:16-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:13:17-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:13:19-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-03-15T21:13:20-0400 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
File details come from the government source that posted it. Updated .