1364315_dwg_08of18_PH1_V2_Fire Protection.pdf

PDF 1 MB Posted

Attached to
P-678 Dry Dock 8 Saltwater System for CVN-78, Norfolk Naval Shipyard, Portsmouth, Virginia
Solicitation number
N40085-22-R-2598_Drawings
Issued by

About this file

This document package includes construction drawings and specifications for a federal solicitation seeking fire protection system upgrades at a naval shipyard. The solicitation, number N40085-22-R-2598, is for upgrades to the saltwater system and fire alarm infrastructure for Dry Dock 8 at Norfolk Naval Shipyard in Portsmouth, Virginia. Offerors are directed to separate notices for access to the detailed drawings and specifications. The drawings depict the existing pumpwell structure and layouts for the proposed fire alarm system at multiple levels, along with details of devices, panels, and wiring. Specifications include notes outlining requirements for equipment, installation, inspections, warranties, and as-built drawings. The work involves installation and integration of a new addressable fire alarm system with controls, detectors, strobes, horns, wiring and panels to replace existing non-addressable systems.

The soliciting agency is the Naval Facilities Engineering Command within the Department of the Navy. The opportunity type is listed as a Special Notice rather than a standard solicitation. No pricing, response dates or other procurement terms are included in the document package itself.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Mechanical | Electrical | Plumbing | Fire Protection 4456 Corporation Ln, Ste 320 Tel: (757) 502-8882

Virginia Beach, Virginia 23462 Fax: (757) 499-1757

ADVANCED

ENGINEERING

CONSULTANTS

SECTION, DETAIL OR ELEVATION

IDENTIFICATION MARK

PLATE NUMBER WHERE SECTION,

DETAIL OR ELEVATION IS TAKEN

SECTION, DETAIL OR ELEVATION TITLE

PLATE NUMBER WHERE

DETAIL IS DRAWN

DETAIL NUMBER

DETAIL CALLOUT SYMBOL

SECTION CUT SYMBOL

SECTION LETTER

PLATE NUMBER WHERE

SECTION IS DRAWN

VIEW SECTION

DETAIL/SECTION TITLE

XX

X-XXX

XX

X-XXX

XX

X-XXX

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

Y S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

DSN

N40085-22-R-2598

C U s e rs

\E ri n C

\D o c u m e n ts

\D R

Y D

P

-1

-F

-D R

Y D

E ri n C

V

E R

.r v t

/2

/2

:5

:5

A

M

1-FA001

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

F

IR

E A

LA

R

M G

E N

E R

A L

S H

E E

T

AEC

12857653

PJB EBC

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL / TLH

1364315

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

DSN

FIRE PROTECTION ABBREVIATIONS

AFF ABOVE FINSHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AWG AMERICAN WIRE GAUGE

CD CANDELA

dBA DECIBEL A-WEIGHTED

EMT ELECTRICAL METALLIC TUBE

EOLR END OF LINE RESISTOR

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

FM FACTORY MUTUAL

IDC INITIATING DEVICE CIRCUIT

NAC NOTIFICATION APPLIANCE CIRCUIT

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NICET NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING

TECHNOLOGIES

NTS NOT TO SCALE

SLC SIGNALING LINE CIRCUIT

SPD SURGE PROTECTION DEVICE

THHN THERMOPLASTIC HIGH HEAT-RESISTANT NYLON-COATED

TYP. TYPICAL

UFC UNITED FACILITIES GUIDE

UL UNDERWRITERS LABORATORIES

V VOLTS

WP WEATHER AND DIRECT HOSE STREAM PROOF (NEMA 4)

FIRE ALARM SYMBOLS

S

FACP

R

MANUAL PULL STATION (48" TO HANDLE OF DEVICE)

SMOKE DETECTOR

RELAY FOR CONNECTION WITH MECHANICAL CONTROLS AND

DEVICES

FIRE ALARM CONTROL PANEL

HORN (80" AFF TO BOTTOM OF DEVICE)

HORN WITH STROBE (80" AFF TO BOTTOM OF DEVICE)

XXcd, WHEN USED, INDICATE THE CANDELA RATING OF DEVICE

STROBE (80" AFF TO BOTTOM OF DEVICE)

XXcd, WHEN USED, INDICATE THE CANDELA RATING OF DEVICE

RADIO TRANSCEIVER

MONITOR MODULE

RT

MM

EOL END OF LINE RESISTOR

XXcd

XXcd

ADDRESSIBLE OUTPUT MODULEAOM

F

F H

GENERAL FIRE ALARM NOTES

1. THIS SYSTEM SHALL BE AN ANALOG/ADDRESSABLE FIRE ALARM SYSTEM.

2. THE FIRE ALARM DRAWINGS ARE SCHEMATIC IN NATURE AND SHOW A

MINIMAL QUANTITY OF DEVICES. CONTRACTOR SHALL DETERMINE THE FINAL

QUANTITY AND LOCATION OF ALL DEVICES IN ACCORDANCE WITH THE

SPECIFICATIONS, CONTRACT DRAWINGS, AND MANUFACTURER'S WRITTEN

RECOMMENDATIONS TO BE COMPLIANT WITH ALL APPLICABLE CODES AND

STANDARDS. ADDITIONAL DEVICES SHALL BE PROVIDED FOR A FULLY

FUNCTIONING FIRE ALARM SYSTEM AS REQUIRED BY NFPA 72, UFC 3-600-01.

3. SIGNALING LINE, NOTIFICATION APPLIANCE, AND INITIATING DEVICE

CIRCUITS SHALL BE CLASS B.

4. ALL EXPOSED FIRE ALARM CONDUITS AND JUNCTION BOXES IN UNFINISHED

AREAS SHALL BE PAINTED RED OR PRE-FINISHED RED FROM THE FACTORY.

CONDUIT AND JUNCTION BOXES EXPOSED IN FINISHED AREAS SHALL BE

FINISHED TO MATCH ADJACENT FINISHES. ALL JUCNTION BOXES SHALL HAVE

A PERMANENT, MACHINE PRINTED LABEL STATING "FIRE ALARM CIRCUIT" ON

THE INSIDE COVER.

5. ALL SYSTEM POWER AND GROUND CIRCUITS SHALL BE TYPE THHN SOLID

COPPER SIZED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS

AND THE APPLICABLE CODES AND BE INSTALLED IN EMT CONDUIT.

6. ALL WIRING, CABLES, BOXES, THROUGHS, AND OTHER RELATED EQUIPMENT

SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE.

7. CONDUCTORS SHALL BE RUN FROM DEVICE TO DEVICE WITHOUT SPLICES.

WIRE NUTS SHALL BE PROHIBITED. TERMINAL STRIPS BE UTILIZED WHERE

CONDUCTORS CANNOT BE DIRECTLY SHALL TERMINATED AT THE DEVICE

(E.G. PIGTAILS OFF A HEAT DETECTOR).

8. FIRE ALARM EQUIPMENT PANELS SHALL NOT BE USED AS RACEWAY FOR

ROUTING POWER WIRING OR LOW VOLTAGE WIRING. ONLY WIRING

TERMINATING WITH THE PANEL SHALL BE ROUTED INTO THE PANEL. POWER

WIRING AND POWER LIMITED WIRING SHALL BE SEPARATED BY A MINIMUM

OF TWO INCHES.

9. ALL DEVICES MUST BE UL LISTED AND NEMA 4 RATED.

10. ALL POWER SUPPLIES TO FACP AND TRANSMITTERS SHALL BE PROVIDED

WITH SPD. ALL SLC, NAC, OR IDC ENTERING OR LEAVING THE BUILDING

SHALL BE PROVIDED WITH SPD. EXCEPTION: CIRCUITS TO DEVICES

MOUNTED DIRECTLY ON THE EXTERIOR OF THE BUILDING.

11. HORNS AND STROBES PROVIDED AT THE SAME LOCATION MAY BE A SINGLE

UNIT.

12. SOUND PRESSURE LEVEL FROM AUDIBLE ALARM APPIANCES SHALL NOT

EXCEED 110 dBA IN ANY OCCUPIED AREA.

13. NO FABRICATION OR INSTALLATION OF FIRE ALARM SYSTEM IS ALLOWED

WITHOUT APPROVED SHOP DRAWING SUBMITTALS.

14. PROVIDE ALL HORNS WITHIN NOTIFICATION DEVICES FOR THE PUMPWELL

AND ENTRY WALKWAY AS LOW FREQUENCY (520 HERTZ) DEVICES.

GENERAL FIRE PROTECTION NOTES

1. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO

SHOW THE EXACT LOCATIONS OF COMPONENTS, NOR SHOW ALL SYSTEM

COMPONENTS. CONTRACTOR MUST PROVIDE ADDITIONAL OFFSETS OR

FITTINGS REQUIRED FOR PROPER INSTALLATION, COORDINATION WITH OTHER

TRADES, AND/OR TO MAINTAIN PROPER CLEARANCES.

2. DRAWINGS ARE NOT TO BE SCALED. DIMENSIONS MUST GOVERN. CONTRACTOR

MUST VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE CONCERNING

NEW WORK BEFORE PROCEEDING WITH INSTALLATION IN AREAS WITH

NUMEROUS OBSTRUCTIONS INCLUDING STRUCTURE, EQUIPMENT, AND PIPING.

THIS WILL REQUIRE ON SITE CUTTING AND VERIFICATION.

3. ANY INFORMATION CONFLICTS BETWEEN THE SPECIFICATIONS AND DRAWINGS

MUST BE BROUGHT TO ENGINEER'S AND CONTRACTING OFFICER'S ATTENTION.

THE CONTRACTOR(S) MUST NOT PROCEED WITH ANY WORK, EXCEPT AT THEIR

OWN RISK, UNTIL CLARIFICATIONS OF THE CONFLICTS ARE ISSUED TO THE

CONTRACTOR(S) BY THE CONTRACTING OFFICER.

4. NO ASBESTOS CONTAINING MATERIALS MUST BE USED ON THIS PROJECT.

5. THE TERM "PROVIDE" MUST MEAN THE CONTRACTOR MUST FURNISH, INSTALL,

AND CONNECT FOR A COMPLETE AND OPERATIONAL SYSTEM.

6. ALL WORK MUST COMPLY IN ALL RESPECTS WITH THE REQUIREMENTS OF

THESE BID DOCUMENTS.

7. ALL MATERIAL AND LABOR MUST BE UNDER WARRANTY FOR ONE YEAR FROM

THE DATE OF FINAL ACCEPTANCE BY THE CONTRACTING OFFICER. ANY

DEVICES OR EQUIPMENT FOUND FAULTY MUST BE REPLACED AS PART OF THE

WARRANTY,

8. A SET OF APPROVED DRAWINGS FOR EACH SYSTEM MUST BE MAINTAINED ON

SITE AND ALL FIELD CHANGES MUST BE RED LINED ON THE DRAWINGS.

CONTRACTOR MUST PREPARE "AS-BUILT" DRAWINGS IN ELECTRONIC

(AUTOCAD) FORMAT, REFLECTING ACCURATE FIELD CONDITIONS.

9. ALL OPENING OR DAMAGE TO WALLS OR FLOORS FROM PENETRATIONS,

REMOVALS, INSTALLATIONS, OR OTHER ACTIONS OF THE CONTRACTOR MUST

BE PATCHED, REPAIRED, AND PAINTED WITH MATERIALS BY THE CONTRACTOR

TO MATCH ADJACENT WORK, WHETHER SPECIFICALLY NOTED OR NOT. REPAIRS

ARE AT THE CONTRACTORS EXPENSE.

10. PIPING AND OTHER ELEMENTS MUST NOT BE UTILIZED AS LADDERS,

SCAFFOLDING OR WORK PLATFORMS.

11. NO STRUCTURAL MEMBERS MUST BE CUT, DRILLED, OR BURNED WITHOUT THE

KNOWLEDGE AND WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER AND

THE CONTRACTING OFFICER.

FACP FUNCTIONAL MATRIX - PUMPWELL

ALARM CONDITIONS A

C

T

IV

A T

E V

IS

U

A L

"F

IR

E

S T

R O

B E

S

A C

T

IV

A T

E N

O T

IF

IC

A T

IO

N

D E

V

IC

E O

N E

X T

E R

IO

R

O F

B U

IL

D

IN

G

A C

T

IV

A T

E A

U D

IB

LE

F

IR

E A

LA

R

M E

V A

C U

A T

IO

N

A

LA

R M

C O

N D

T

IO

N A

T F

A C

P

S U

P E

R V

IS

O

R Y

C O

N D

IT

IO

N A

T F

A C

P

T R

O U

B

LE

C O

N D

IT

IO

N A

T F

A C

P

T R

A N

S M

IT

A

LA

R

M S

IG

N

A L

T O

F

IR

E D

E P

T . V

IA

T

R A

N S

M

IT

T E

R

T R

A N

S M

IT

S

U P

E R

V

IS

O R

Y S

IG

N

A L

T O

F

IR

E D

E P

T . V

IA

T

R A

N S

M

IT

T E

R

T R

A N

S M

IT

T

R O

U B

LE

S

IG

N

A L

T O

F

IR

E D

E P

T . V

IA

T

R A

N S

M

IT

T E

R

S H

U T

D O

W N

A H

U

ALARM CONDITIONS

AREA SMOKE DETECTOR ACTIVATION • • • • •

DUCT SMOKE DETECTOR • • • • • •

MANUAL PULL STATION • • • • •

SUPERVISORY CONDITIONS

COMPONENT COMMON SUPERVISORY • •

TROUBLE CONDITIONS

AC POWER FAILURE • •

COMPONENT COMMON TROUBLE • •

GROUND FAULT • •

LOW BATTERY • •

NOTIFICATION APPLICANCE CIRCUIT SHORT • •

OPEN CIRCUIT FAULT • •

OTHER TROUBLE CONDITION • •

FIRE ALARM ANNUNCIATOR PANELFAA

S Y

M D

E S

C R

IP

T

I O N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/2

8/

IS

SU

ED

F

OR

B

ID

Virginia Beach, Virginia 23462 Fax: (757) 499-1757

ADVANCED

ENGINEERING

CONSULTANTS

MOTOR LEVEL

SEE SHEET 1-FA102

INTERMEDIATE LEVEL

SEE SHEET 1-FA103

MAIN PUMP LEVEL

SEE SHEET 1-FA104

PW8-DRAINAGE PUMP

-74' - 8 3/4"

SUCTION CHAMBER

-70' - 8 3/4"

PW8-MAIN PUMP

-57' - 0"

PW8-INTERMEDIATE

-35' - 0"

PW8-MOTOR

-20' - 0"

BOT PUMPWELL HALL

-15' - 0"

TOP PUMPWELL HALL

-6' - 0"

PW-MDP-2 PW-MDP-3 PW-MDP-4

PW-MDP-2

MOTOR

PW-MDP-3

MOTOR

PW-MDP-4

MOTOR

PW1 6

PW8-DP-5 (PW8-

DP-4 LOCATED

BEHIND PUMP)

PW8-DP-2 (PW8-DP-1

LOCATED BEHIND)

(E) DP-3

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

DSN

N40085-22-R-2598

C U s e rs

\E ri n C

\D o c u m e n ts

\D R

Y D

P

-1

-F

-D R

Y D

E ri n C

V

E R

.r v t

/2

/2

:5

:5

A

M

1-FA100

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

P U

M P

W E

LL

F

IR

E

A

LA

R M

K

E Y

P

LA

N

AEC

12857654

PJB EBC

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL / TLH

1364315

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

DSN

SHEET NOTES

1/8" = 1'-0" A1

KEY ELEVATION - PUMPWELL 8 FIRE ALARM

1 REFER TO SHEET 1-FA001 FOR LEGEND, SYMBOLS AND ABBREVIATIONS.

2 CANDELA RATINGS INDICATED ON THE DRAWINGS ARE THE MINIMUM

RATING BASED ON LAYOUT. CONTRACTOR'S NICET DESIGNER CAN

PROVIDE ALTERNATE SPACING AND INTENSITY LAYOUTS BASED ON

DEVICES FROM THEIR AVAILABLE SUPPLIER.

KEY PLAN

MOTOR

83'-0"

INTERMED.

68'-0"

MAIN PUMP

46'-0"

DRAINAGE

28'-3 1/4"

COPING

103'-0"

SUC. CHAM.

32'-3"4' 8' 16'0'

S Y

M D

E S

C R

IP

T

I O N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/2

8/

IS

SU

ED

F

OR

Virginia Beach, Virginia 23462 Fax: (757) 499-1757

ADVANCED

ENGINEERING

CONSULTANTS

S

F

15 CD, WP

15 CD, WP

34 CD

34 CD

34 CD

34 CD

15 CD

F A

C P

1RT

MDP-2 MDP-3 MDP-4

S D

F A

A

CONTROL RM.

D S

C

34 CD

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

DSN

N40085-22-R-2598

C U s e rs

\E ri n C

\D o c u m e n ts

\D R

Y D

P

-1

-F

-D R

Y D

E ri n C

V

E R

.r v t

/2

/2

:5

:0

A

M

1-FA102

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

P U

M P

W E

LL

F

IR

E A

LA

R

M P

LA

N

M

O

TO

R

AEC

12857655

PJB EBC

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL / TLH

1364315

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

DSN

SHEET NOTES

SHEET KEYNOTES#

1/8" = 1'-0" C1

PUMPWELL - FIRE ALARM PLAN - MOTOR LEVEL

1 FIRE ALARM CONTROL PANEL, BOTTOM OF DISPLAY READOUT NO MORE

THAN 5'-0" ABOVE FINISHED FLOOR

2 PROVIDE STOBE DEVICE WITHIN EXISTING TOLET/SHOWER ROOM.

3 CONNECT FIRE ALARM SYSTEM INTO EXISTING DUCT SMOKE DECTECTOR.

PROVIDE ANY MODULES NECESSARY TO MAKE THIS CONNECTION.

4 MOUNT AN ANTENNA FOR THE RADIO TRANSCEIVER ON THE ENTRY SHED

FOR THE PUMPWELL. ROUTE WIRING THROUGH ENTRY CORRIDOR AND TO

RECEIVER ON CONTROL ROOM WALL.

1 REFER TO SHEET 1-FA001 FOR LEGEND, SYMBOLS AND ABBREVIATIONS.

2 CANDELA RATINGS INDICATED ON THE DRAWINGS ARE THE MINIMUM

RATING BASED ON LAYOUT. CONTRACTOR'S NICET DESIGNER CAN

PROVIDE ALTERNATE SPACING AND INTENSITY LAYOUTS BASED ON

DEVICES FROM THEIR AVAILABLE SUPPLIER.

KEY PLAN

MOTOR

83'-0"

INTERMED.

68'-0"

MAIN PUMP

46'-0"

DRAINAGE

28'-3 1/4"

COPING

103'-0"

SUC. CHAM.

32'-3"

PLAN

NORTH

4' 8' 16'0'

S Y

M D

E S

C R

IP

T

I O N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/2

8/

IS

SU

ED

F

OR

Virginia Beach, Virginia 23462 Fax: (757) 499-1757

ADVANCED

ENGINEERING

CONSULTANTS

34 CD

34 CD34 CD34 CD34 CD

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

DSN

N40085-22-R-2598

C U s e rs

\E ri n C

\D o c u m e n ts

\D R

Y D

P

-1

-F

-D R

Y D

E ri n C

V

E R

.r v t

/2

/2

:5

:0

A

M

1-FA103

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

P U

M P

W E

LL

F

IR

E A

LA

R

M P

LA

N

IN

TE

R

M E

D

IA

TE

AEC

12857656

PJB EBC

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL / TLH

1364315

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

DSN

SHEET NOTES

1/8" = 1'-0" C1

PUMPWELL - FIRE ALARM PLAN - INTERMEDIATE LEVEL

1 REFER TO SHEET 1-FA001 FOR LEGEND, SYMBOLS AND ABBREVIATIONS.

2 CANDELA RATINGS INDICATED ON THE DRAWINGS ARE THE MINIMUM

RATING BASED ON LAYOUT. CONTRACTOR'S NICET DESIGNER CAN

PROVIDE ALTERNATE SPACING AND INTENSITY LAYOUTS BASED ON

DEVICES FROM THEIR AVAILABLE SUPPLIER.

KEY PLAN

MOTOR

83'-0"

INTERMED.

68'-0"

MAIN PUMP

46'-0"

DRAINAGE

28'-3 1/4"

COPING

103'-0"

SUC. CHAM.

32'-3"

PLAN

NORTH

4' 8' 16'0'

S Y

M D

E S

C R

IP

T

I O N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/2

8/

IS

SU

ED

F

OR

Virginia Beach, Virginia 23462 Fax: (757) 499-1757

ADVANCED

ENGINEERING

CONSULTANTS

34 CD34 CD34 CD

75 CD

MDP-2 MDP-3 MDP-4

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

DSN

N40085-22-R-2598

C U s e rs

\E ri n C

\D o c u m e n ts

\D R

Y D

P

-1

-F

-D R

Y D

E ri n C

V

E R

.r v t

/2

/2

:5

:0

A

M

1-FA104

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

P U

M P

W E

LL

F

IR

E A

LA

R

M P

LA

N

M

A

IN

P U

M P

AEC

12857657

PJB EBC

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL / TLH

1364315

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

DSN

SHEET NOTES

SHEET KEYNOTES#

1/8" = 1'-0" C1

PUMPWELL - FIRE ALARM PLAN - MAIN PUMP LEVEL

1 REFER TO SHEET 1-FA001 FOR LEGEND, SYMBOLS AND ABBREVIATIONS.

2 CANDELA RATINGS INDICATED ON THE DRAWINGS ARE THE MINIMUM

RATING BASED ON LAYOUT. CONTRACTOR'S NICET DESIGNER CAN

PROVIDE ALTERNATE SPACING AND INTENSITY LAYOUTS BASED ON

DEVICES FROM THEIR AVAILABLE SUPPLIER.

KEY PLAN

MOTOR

83'-0"

INTERMED.

68'-0"

MAIN PUMP

46'-0"

DRAINAGE

28'-3 1/4"

COPING

103'-0"

SUC. CHAM.

32'-3"

PLAN

NORTH

4' 8' 16'0'

1 HORN/STOBE TO BE MOUNTED 6'-8" ABOVE CATWALK WITHIN THIS

CHAMBER.

S Y

M D

E S

C R

IP

T

I O N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/2

8/

IS

SU

ED

F

OR

Virginia Beach, Virginia 23462 Fax: (757) 499-1757

ADVANCED

ENGINEERING

CONSULTANTS

RADIO TRANSCEIVER

TO TRANSMIT SIGNAL

TO BASE WIDE

SYSTEM

FACP

BATTERY CABINET

FINISHED FLOOR

5' -0

F

R O

M F

LO

O

R T

O D

IS

P

LA

Y

P A

N E

L O

N F

A C

P

CORNER OF CONTROL ROOM

F

FACP

S

RT

EOL

WP

POWER FOR FACP FROM PANEL PW8-4,

CIRCUIT 20 AND RADIO TRANSCEIVER FROM

PANEL PW-8-4, CIRCUIT 1, REFER TO SHEET

1-EP101

CONNECT TO EXISTING BASE FA

SYSTEM VIA SIGNAL FROM

ANTENNA, WHICH IS TO BE

INSTALLED ON PUMPWELL ENTRY

SHED.

PROVIDE 120VAC SURGE SUPPRESSION

DEVICES FOR EACH UNIT.

S D

NOTE: NOT ALL DEVICES ARE INDICATED ON RISER DIAGRAM

FAA

FAA POWERED FROM FACP

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

AS NOTED

F

IL

E N

A M

E

P

LO

T T

E D

DSN

N40085-22-R-2598

C U s e rs

\E ri n C

\D o c u m e n ts

\D R

Y D

P

-1

-F

-D R

Y D

E ri n C

V

E R

.r v t

/2

/2

:5

:0

A

M

1-FA501

P D

R Y

D O

C K

S

A L T

W A

T E

R S

Y S

T E

M

F O

R C

V N

-7

F

IR

E A

LA

R

M D

E

TA

IL

S

AEC

12857658

PJB EBC

02/02/2022

DEVIN POULIN,

C984 FACILITIES PLANNER, NNSY

JTL / TLH

1364315

P O

R T

S M

O U

T H

, V

IR

G

IN

IA

N

O R

F O

LK

N

A V

A L

S H

IP

Y

A R

D

EJA

DSN

NOT TO SCALE

A4

FIRE ALARM CONTROL PANEL DETAIL

NOT TO SCALE

C4

FIRE ALARM RISER DIAGRAM

S Y

M D

E S

C R

IP

T

I O N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/2

8/

IS

SU

ED

F

OR

1-FA001 - FIRE ALARM GENERAL SHEET
1-FA100 - PUMPWELL 8 - FIRE ALARM - KEY PLAN
1-FA102 - PUMPWELL - FIRE ALARM PLAN - MOTOR
1-FA103 - PUMPWELL - FIRE ALARM PLAN - INTERMEDIATE
1-FA104 - PUMPWELL - FIRE ALARM PLAN - MAIN PUMP
1-FA501 - FIRE ALARM DETAILS

2022-02-25T10:34:40-0500

2022-02-25T10:34:51-0500

2022-02-25T10:34:51-0500

2022-02-25T10:34:51-0500

2022-02-25T10:34:51-0500

2022-02-25T10:34:51-0500

2022-02-25T10:35:04-0500

2022-02-25T10:35:14-0500

2022-02-25T10:35:14-0500

2022-02-25T10:35:14-0500

2022-02-25T10:35:14-0500

2022-02-25T10:35:14-0500

2022-03-15T21:12:23-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:12:35-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:12:37-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:12:40-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:12:41-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:12:44-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:13:00-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:13:14-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:13:16-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:13:17-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:13:19-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-03-15T21:13:20-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.

File details come from the government source that posted it. Updated .