Am4 Attach08 05.28.20 Water Addendum #2.pdf

PDF 12 MB Posted

Attached to
USFS Colorado Springs Air Tanker Base
Solicitation number
1282BH20R0003
Issued by

About this file

This document is an addendum to construction plans for a water utility project to support the USDA Forest Service Colorado Springs Airtanker Base. The addendum removes several proposed items from the project scope, including a 6-inch fire line, 1-inch and 2-inch domestic water lines, fire hydrant FH-2, and all associated valves and fittings. These removed items will instead be constructed as part of separate plans for the USFS Airtanker Base project to be submitted later by the engineering firm Robert Peccia & Associates. The water utility project construction plans show water and sanitary sewer infrastructure to serve the Airtanker Base, including over 2,100 feet of 12-inch water main along Milton E. Proby Parkway, fittings, valves, fire hydrants, utility crossings, and service connections. Colorado Springs Utilities provides approval of the plans.

View the file

Other files

File Type Posted
AMEND006 Drawings 20200729.pdf PDF
AMEND006 Bidder Questions FINAL PART2.pdf PDF
1282BH20R0003 Amendment6 SF30.pdf PDF
AMEND006 Bidder Questions FINAL PART1.pdf PDF
AMEND006 ScheduleOfItems COSATB 20200729.xlsx XLSX spreadsheet
AMEND006 QandA Amendment Instructions 20200729.docx DOCX document
AMEND006 Specifications 20200729.pdf PDF
Amendment5 SF30.pdf PDF
Am4 Attach06 DEICE - CCD 02_COMBINED_SIGNED.pdf PDF
Am4 Attach05 DEICE - CCD 01 COMPLETE_SIGNED.pdf PDF
Am4 Attach11 05.28.20 Sewer Addendum #1 and #2.pdf PDF
Am4 Attach03 Technical Requirements Briefing by Lacie.docx DOCX document
Am4 Attach10 01a. COSA USFS Wastewater Plans - Addendum#1.pdf PDF
Am4 Attach09 COSA USFS Wastewater Plans COMPLETE.pdf PDF
Am4 Attach07 COSA USFS Water Plans COMPLETE.pdf PDF
Amendment04 SF30.pdf PDF
Am4 Attach02 presolicitation attendees.docx DOCX document
Am4 Attach04 20200212 COS DEICE IFC PLANS.pdf PDF
Am4 Attach01 Preproposal Conference Agenda.docx DOCX document
Amendment3 SF30.pdf PDF
Amendment3 Attach_02_COSATB_SPECIFICATIONS COMBINED_20191023_20200430 v2.pdf PDF
AMENDMENT2 1282BH20R0003.pdf PDF
AMENDMENT1 1282BH20R0003.pdf PDF
Solicitation v2.pdf PDF
Attach_04_ScheduleOfItems_COSATB.xlsx XLSX spreadsheet
SF1442 Solicitation.pdf PDF
Attach_02_COSATB_SPECIFICATIONS COMBINED_20191023_20200430.pdf PDF
Attach_03_COS ATB Special Inspection Reqts.pdf PDF
Attach_01_COSATB_Final DWG w Cover Sheet 10-23-19.pdf PDF
Attach_07_Technical_Proposal_Submission_Aid.pdf PDF
Attach_05_EM_385_1_1_2014.pdf PDF
ATTACH_06_Wage_Determination.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SERVICE

ROAD

S E

R V

I C

E

R O

A D

M I L

T O

N

E

P

R O

B Y

P

A R

K W

A Y

M I L

T O

N

E

P

R O

R

K W

A Y

MILTON E. PROBY

PARKWAY AIRPORT EXIT

A I R

C

R

G O

A

D

MILTON E. PROBY PARKWAY

COLORADO SPRINGS

AIRPORT TERMINAL

INTEGRATION LOOP

C

R

E

S

T

E

R

K

W

Y

EMBRAER

HEIGHTS

G

R

I

N

N

E

L

V

D

PROJECT

S POWERS BLVD

C O

SA

U

SF

S

W A

TE

R

C O

N

ST

R U

C

TI

O N

P

LA

N S

C O

L O

R A

D

S

R

I N

G S

C

O L O

R A

D O

D A

T E

N O

A

M E

N D

M E

N T

DATE

SHEET

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

0 1"

OF

02/24/2020

BENCHMARK

VICINITY MAP

SCALE 1" = 2000'

COLORADO SPRINGS AIRPORT

COSA USFS

WATER CONSTRUCTION PLANS

LOCATED IN A PORTION OF SECTIONS 4, 5 AND 6 OF TOWNSHIP 15 SOUTH, RANGE 65 WEST, ALL OF THE 6TH

PRINCIPAL MERIDIAN, LOCATED IN THE CITY OF COLORADO SPRINGS, COUNTY OF EL PASO, STATE OF COLORADO

SHEET INDEX

C O

V

ER

S H

EE

T

CSFD ACCEPTANCE

ALL FIRE HYDRANTS SHALL BE INSTALLED ACCORDING TO COLORADO

SPRINGS UTILITIES' WATER LINE EXTENSION AND SERVICE STANDARDS.

THE NUMBER OF HYDRANTS AND HYDRANT LOCATIONS AS SHOWN ON THIS

WATER PLAN ARE CORRECT AND ADEQUATE TO SATISFY THE FIRE

PROTECTION REQUIREMENTS AS SPECIFIED BY THE CITY OF COLORADO

SPRINGS FIRE DEPARTMENT.

SIGNED: ____________________________________________________________

CSFD, DIVISION OF THE FIRE MARSHAL

CSFD PLAN REVIEW NO.: _______________________________________

ACCORDING TO CALCULATIONS REVIEWED BY COLORADO SPRINGS UTILITIES, THE THEORETICAL AVAILABLE FIRE FLOW AT

EACH FIRE HYDRANT NODE UNDER MAXIMUM DAY DEMAND CONDITIONS WITH A 20 PSI RESIDUAL IS AS FOLLOWS (ACTUAL

FIRE FLOW MAY VARY DUE TO VARIOUS PARAMETERS):

NODE

FIRE FLOW

(GPM)

PSI @ MDD

FOR BURIED UTILITY INFORMATION

THREE (3) BUSINESS DAYS

BEFORE YOU DIG

CALL 811

(OR 1-800-922-1987)

UTILITY NOTIFICATION

CENTER OF COLORADO (UNCC)

WWW.UNCC.ORG

R

PROJECT INFORMATION

FIRE FLOW INFORMATION

APPROVAL BLOCKS

ABBREVIATIONS

BO

B.O.P.

BV

CL

CRA

CTRB

DC

DEF

DIP

DTL

ESMT

EX

FH

GV

H BEND

HORIZ

I

BLOW-OFF

BOTTOM OF PIPE

BUTTERFLY VALVE

CENTERLINE

CONCRETE REVERSE ANCHOR

CONCRETE THRUST REACTION BLOCK

DEFLECTION COUPLING

DEFLECTION

DUCTILE IRON PIPE

DETAIL

EASEMENT

EXISTING

FIRE HYDRANT

GATE VALVE

HORIZONTAL BEND

HORIZONTAL

INVERT

LF

MJR

PIC

PR

PRV

PVC

RDWY

SD

SS

SSC

SSMH

STA

T.O.P.

TYP

V BEND

WL

X-ING

LINEAR FEET

MECHANICAL JOINT RESTRAINT

PUBLIC IMPROVEMENT CORRIDOR

PROPOSED

PRESSURE REDUCING VALVE

POLYVINYL CHLORIDE

ROADWAY

STORM DRAIN

SANITARY SEWER

SOLID SLEEVE COUPLING

SANITARY SEWER MANHOLE

STATION

TOP OF PIPE

TYPICAL

VERTICAL BEND

WATERLINE

CROSSING

LEGEND

8''SS

8''W

PR BEND FITTINGS

PR TEE & CROSS FITTINGS

PR FIRE HYDRANT

PR VALVE

CROSSING

PR REDUCER

PR PLUG

PR TEMPORARY BLOWOFF

PR 8" WATERLINE EXISTING MAJOR CONTOUR

EXISTING MINOR CONTOUR

PROPOSED MAJOR CONTOUR

PROPOSED MINOR CONTOUR

PR SANITARY SEWER & MANHOLE

(SIZE AS NOTED ON PLANS)

8''SS

EX SANITARY SEWER & MANHOLE

(SIZE AS NOTED ON PLANS)

8''W

PR WATERLINE

(SIZE AS NOTED ON PLANS)

8''W

EX WATERLINE

(SIZE AS NOTED ON PLANS)

PR STORM DRAIN

(SIZE AS NOTED ON PLANS)

EX STORM DRAIN

(SIZE AS NOTED ON PLANS)

COSA ROADWAY, PROPERTY LINE

EASEMENT

COLORADO SPRINGS UTILITIES

WATER CONSTRUCTION PLAN APPROVAL

PROJECT NUMBER: ______________

CSU SHEET _____ OF _____

APPROVAL EXPIRES ONE (1) YEAR FROM THE DATE ABOVE AND RESUBMITTAL OF THESE PLANS FOR REVIEW AND

APPROVAL IS REQUIRED IF CONSTRUCTION DOES NOT BEGIN DURING THIS PERIOD.

PROJECT TEAM

OWNER

COLORADO SPRINGS AIRPORT

7770 MILTON E. PROBY PARKWAY, SUITE 550

COLORADO SPRINGS, CO 80916

CONTACT: TROY STOVER

(719) 550-1967

CIVIL ENGINEER

ENERTIA CONSULTING GROUP, LLC

1529 MARKET STREET, SUITE 200

DENVER, CO 80202

CONTACT: BONNER GILMORE

(303) 875-7131

AVIATION ENGINEER

RS&H

7800 E. UNION AVE, SUITE 700

DENVER, CO 80237

CONTACT: ARLANDO GILBERT, PE

(303) 409-7956

SURVEYOR

POLARIS SURVEYING, INC.

1903 LELARAY STREET, SUITE 102

COLORADO SPRINGS, CO 80909

CONTACT: RANDALL HENCY, PLS

(719) 448-0844

SHEET NO DESCRIPTION

COVER SHEET

GENERAL NOTES

OVERALL UTILITY PLAN

WAT-1.0 STA: -1+00 - 11+00

WAT-1.0 STA: 11+00 - 23+00

WAT-2.0 STA: 0+00 TO 9+00

WATER DETAILS

FEB. 24, 2020

BENCH MARK: #5 REBAR LOCATED APPROXIMATELY 75' SOUTHEAST OF THE SOUTHEAST CORNER OF THE LIFT STATION

BUILDING MARKED WITH 4' CROSS LATH.

NORTHING: 62654.52

EASTING: 29107.44

ELEVATION: 5924.01

DATUM: NAVD 88

FIMS MAP NUMBER: Q-40

TAX SCHEDULE NO.: 5400000211 (A PORTION 0F)

PRESSURE ZONE: HIGHLINE

MAX STATIC PRESSURE: 135 PSI

UTILITY DESIGN CAD FILE NO.: N/A

DEVELOPMENT PLAN NO.: N/A

PLAT REC. NO.: 94150256

PUBLIC UTILITY EASEMENT REC. NO.: N/A

NOTICE OF PRIVATE WATER SYSTEM REC. NO.: N/A

2019-W185

FH-1 (DHA) 2,800

FH-2 (DHB) 3,000

SIGNED: ____________________________________________________________

OWNER/DEVELOPER

TROY STOVER_______________________________________________

OWNER/DEVELOPER (PRINT NAME)

DBA: COLORADO SPRINGS AIRPORT________________________________

ADDRESS: 7770 MILTON E. PROBY PKWY, SUITE 50_______________________

COLORADO SPRINGS, CO 80916______________________________

PHONE: (719) 550-1967______________________________________________

EMAIL: TSTOVER@SPRINGSGOV.COM________________________________

DATE: 02/24/2020________________

OWNER/DEVELOPER PLAN APPROVAL

THE UNDERSIGNED OWNER/DEVELOPER AGREES THAT THEY SHALL, AT THEIR EXPENSE, BE SOLELY RESPONSIBLE FOR 1)

THE INSTALLATION OF THE PROPOSED UTILITY INFRASTRUCTURE IN ACCORDANCE WITH THESE PLANS, AND 2) ALL

DAMAGES AND DEFECTS ARISING FROM, OR RELATED TO, THE INSTALLATION, MAINTENANCE OR OPERATION OF THE PUBLIC

UTILITY INFRASTRUCTURE FROM THE DATE OF PRELIMINARY ACCEPTANCE FOR A PERIOD OF TWO YEARS, OR UNTIL FINAL

ACCEPTANCE, WHICHEVER IS LATER.

THE UNDERSIGNED UNDERSTANDS THAT ALL PRIVATE UTILITY INFRASTRUCTURE, AS INDICATED ON THESE PLANS, SHALL

REMAIN THE PROPERTY OF THE OWNER AND SHALL BE MAINTAINED BY THE OWNER, AS REQUIRED BY COLORADO SPRINGS

UTILITIES' LINE EXTENSION AND SERVICE STANDARDS.

PUBLIC FACILITIES PROPOSED PRIVATE FACILITIES PROPOSED

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text W

AutoCAD SHX Text S

AutoCAD SHX Text S

FDRTP

Text Box

2020-0358-FH-1

FDRTP

Text Box Roland T. Peterson

FDRTP

CSFD Approval mgackle Snapshot mgackle Snapshot mgackle Text Box X mgackle Text Box mgackle Text Box mgackle CSU Water Approval

SA

U

SF

S

W A

TE

R

C O

N

ST

R U

C

TI

O N

P

LA

N S

C O

L O

R A

R

I N

G S

C

O L O

R A

D O

D A

T E

N O

A

M E

N D

M E

N T

DATE

SHEET

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

0 1"

OF

02/24/2020

G

EN

ER

A

L N

O

TE

S

GENERAL:

1. ALL CONSTRUCTION METHODS AND MATERIALS SHALL MEET COLORADO SPRINGS UTILITIES' WATER

LINE EXTENSION AND SERVICE STANDARDS (WATER LESS).

2. THE CONTRACTOR SHALL OBTAIN LOCATES PRIOR TO ANY EXCAVATION.

3. COLORADO SPRINGS UTILITIES DOES NOT GUARANTEE THE ACCURACY OF LOCATIONS OF EXISTING

PIPELINES, HYDRANTS, VALVES AND SERVICE LINES. IF FIELD CONDITIONS ARE FOUND TO BE

DIFFERENT THAN SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE INSPECTOR AND THE

ENGINEER OF RECORD IMMEDIATELY.

4. NO TREES OR STRUCTURES ARE PERMITTED WITHIN FIFTEEN FEET (15') OF A WATER MAIN.

5. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ANY UTILITY FACILITIES AS A RESULT OF HIS

ACTIONS. THE CONTRACTOR SHALL MAKE ALL THE REQUIRED REPAIRS IMMEDIATELY TO THE

SATISFACTION OF COLORADO SPRINGS UTILITIES.

6. ALL FIELD STAKING SHALL COMPLY WITH THE WATER LESS.

7. THE CONTRACTOR SHALL MAKE THEIR BEST EFFORT TO ENSURE THAT WATER SERVICE TO ADJACENT

PROPERTIES IS MAINTAINED DURING CONSTRUCTION.

8. CORROSION PROTECTION MEASURES SHALL COMPLY WITH THE WATER LESS.

9. NO SERVICE TAPS WILL BE ALLOWED UNTIL THE MAIN IS EXTENDED TO THE NEXT MAIN-LINE VALVE.

10. NO SERVICE TAPS SHALL BE MADE UNTIL AUTHORIZATION HAS BEEN GRANTED BY THE COLORADO

SPRINGS UTILITIES' INSPECTOR.

11. ALL BENDS SHALL BE FIELD STAKED PRIOR TO CONSTRUCTION AND THE STATIONING ON THE FIELD

STAKES SHALL MATCH THE STATIONING ON THE PLANS.

12. FIELD MODIFICATIONS TO A FIRE SERVICE LINE OR FIRE HYDRANT DESIGN OR LOCATION MAY NEED TO

BE APPROVED BY THE DESIGN ENGINEER, COLORADO SPRINGS FIRE DEPARTMENT AND COLORADO

SPRINGS UTILITIES, AS REQUIRED BY THE INSPECTOR.

13. REUSE OR SALVAGE OF ANY MATERIAL IS LEFT TO THE DISCRETION OF THE COLORADO SPRINGS

UTILITIES INSPECTOR.

14. ALL TRENCH BACKFILL AND COMPACTION SHALL BE IN ACCORDANCE WITH SECTION 206 OF THE CITY

OF COLORADO SPRINGS STANDARD SPECIFICATIONS MANUAL.

15. ALL WATER SERVICE LINES SHOULD ENTER THE BUILDING WITHIN 3 FEET OF AN EXTERIOR WALL.

EXPOSED WATER PLUMBING SHALL BE MINIMIZED INSIDE THE BUILDING PRIOR TO THE WATER METER

AND/OR APPROVED BACKFLOW PREVENTION ASSEMBLY OR METHOD.

ANY EXISTING STUBS AND APPURTENANCES THAT WILL NOT BE USED SHALL BE

REMOVED AND REPLACED WITH AN ACCEPTABLE SECTION OF MAIN AT THE EXPENSE OF

THE CONTRACTOR.

A CONNECTION TO AN EXISTING STUB IS PROPOSED. COLORADO SPRINGS UTILITIES

DOES NOT GUARANTEE THE ACCURACY OF THE DEPTHS OR LOCATIONS OF EXISTING

STUBS SHOWN ON ANY “AS-BUILT” DRAWINGS.

A WATER STUB-OUT(S) IS/ARE PROPOSED. COLORADO SPRINGS UTILITIES DOES

NOT GUARANTEE THAT THE DESIGN OR INSTALLATION OF THE PROPOSED WATER

STUB-OUT WILL MEET FUTURE DEVELOPMENT NEEDS.

A WATER QUALITY PLAN HAS BEEN APPROVED FOR THIS PROJECT

N O

T

A P

P L I C

A B

L E

WATER PLAN NOTES

A P

P L I C

A B

L E

WATER PROJECT - SPECIFIC NOTES

COLORADO SPRINGS UTILITIES

WATER CONSTRUCTION PLAN APPROVAL

APPROVAL EXPIRES ONE (1) YEAR FROM THE DATE ABOVE AND RESUBMITTAL OF THESE PLANS FOR REVIEW AND

APPROVAL IS REQUIRED IF CONSTRUCTION DOES NOT BEGIN DURING THIS PERIOD.

FEB. 24, 2020

AutoCAD SHX Text THE CONTRACTOR SHALL NOTIFY COLORADO SPRINGS UTILITIES' INSPECTIONS OFFICE 719-668-4658 A MINIMUM OF 48 HOURS PRIOR TO THE START OF CONSTRUCTION.

AutoCAD SHX Text 1.

AutoCAD SHX Text 2.

AutoCAD SHX Text 3.

AutoCAD SHX Text 4.

mgackle Snapshot mgackle Text Box mgackle Text Box

S

S S

S S

S

S

S S

S S

S

S

S

S S

S S

S

12''W

12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W

W

12''W 12''W 12''W 12''W 12''W 12''W 12''W

12''W

W

W

W

W

S

W

W

W

W

S

S

S

8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS

S

S

8''SS 8''SS 8''SS 8''SS 8''SS 8''SS

S

S

W

AT

-2 .0

WAT-1.0

WAT-1.0

DE-ICE APRON

DE-ICE POND

DETENTION

POND

M

IL

TO

N

E . P

RO

BY

P

AR

K W

AY

OLD DRENNAN ROAD

EX

A

C C

ES

S

RO

AD

PR

B

UI

LD

IN

G

PR

B

UI

LD

IN

G

EXISTING 12" DI PUBLIC

SANITARY SEWER

(PN:1996-S185)

EXISTING 12" PVC PUBLIC

SANITARY SEWER

(PN:1994-S115)

EXISTING 16" DIP WL

(PN: NONE)

PROPOSED 12" WATER

PROPOSED 12" WATER

PROPOSED 8" SANITARY SEWER.

SEE WASTEWATER PLANS

PREPARED BY ENERTIA

CONSULTING GROUP, LLC.

PROPOSED DE-ICE

POND OUTLET WORKS-

SEE DE-ICE APRON

PLANS BY RS&H

20' MAINTENANCE ROAD

SEE DETAIL ON SHEET 7.

CONNECT TO

EXISTING 16" WATER

CONNECT TO

EXISTING 16" WATER

PROPOSED HYDRANT

FH-1 TEMPORARY BLOWOFF

EXISTING 16" DIP WL

(PN: NONE)

EXTEND EXIST 24" SD. SEE

DE-ICE APRON PLANS BY

RS&H

EXISTING SANITARY

SEWER MANHOLE

(PN:199-S185)

EXIST EMERGENCY

SPILLWAY. DO NOT DISTURB.

EXISTING 16" DIP WL

(PN: NONE)

EXISTING 16" DIP WL

(PN: NONE)

PROPOSED HYDRANT

FH-2

SAN-1.0

SA

N

-1 .0

EXISTING 60" & 30" SD

EXISTING 30" SD

EXISTING PAVED ROAD

PR 30" SD. SEE DE-ICE

APRON PLANS BY RS&H

PROPOSED 8" SANITARY SEWER.

SEE WASTEWATER PLANS

PREPARED BY ENERTIA

CONSULTING GROUP, LLC.

PROPOSED 8" SANITARY SEWER.

SEE WASTEWATER PLANS

PREPARED BY ENERTIA

CONSULTING GROUP, LLC.

4" FIRE LINE-SEE CIVIL

PLANS BY RPA.

2" DOMESTIC LINE-SEE

CIVIL PLANS BY RPA.

1" DOMESTIC LINE-SEE

CIVIL PLANS BY RPA.

EXISTING 12" DIP WL

(PN: 2006-W051)

EXISTING 18" CULVERT

PROPOSED 36" SD.

SEE DE-ICE APRON

PLANS BY RS&H

PROPOSED 15" ARCH RCP.

SEE RPA STORM DRAIN

PLANS.

EXISTING 60"

STORM DRAIN

30' PIC

50' PIC

50' PIC

EX 50' PIC (APPROX)

FIMS#800171 (MAY 1, 2006)

30' PIC

30' PIC

O V

ER

A

LL

U

TI

LI

TY

P

LA

N

M I L

T O

N

E

P

R O

W

Y

M I L

T O

N

E

P

R O

W

Y

A

R

MILTON E. PROBY PKWY

COLORADO SPRINGS

AIRPORT TERMINAL

INTEGRATION

LOOP

C

R

E

S

T

E

R

R

A

P

K

W

Y

EMBRAER

HEIGHTS

KEY MAP

C O

SA

U

SF

S

W A

TE

R

C O

N

ST

R U

C

TI

O N

P

LA

N S

C O

L O

R A

R

I N

G S

C

O L O

R A

D O

D A

T E

N O

A

M E

N D

M E

N T

DATE

SHEET

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

0 1"

OF

02/24/2020

FEB. 24, 2020

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

12" DIP

AutoCAD SHX Text 0'

AutoCAD SHX Text 100'

AutoCAD SHX Text 200'

AutoCAD SHX Text 50'

AutoCAD SHX Text

SCALE: 1"=100'

AutoCAD SHX Text N

GirtenA Cloud

GirtenA Cloud

GirtenA Cloud

GirtenA Text Box 2 5/28/20 Remove 6" Fire line, 1" and 2" Domestic Services, and FH-2

GirtenA PolyLine

GirtenA PolyLine

GirtenA Text Box

GirtenA PolyLine

GirtenA PolyLine

GirtenA Text Box

GirtenA Text Box

GirtenA Text Box Addendum #2 2 Sanitary Sewer Project No. 2019-S086 Water Project No. 2019-W185 Sheets 3 and 6 are provided as Addendum #2 to remove the proposed 6" Fire line, 1" Domestic Line, 2" Domestic Line, Fire Hydrant #2 and all associated valves and fittings from this project scope of work. These items will be constructed as part of the USFS Airtanker Base plans to be submitted by Robert Peccia & Associates Inc. (RPA) at a later date.

S

S

12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W

W

W

12''W 12''W

SS

S

S

8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS

S

S

S

S

8''SS 8''SS

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00

9+00

10+00 11+00

DETENTION

POND

M

IL

TO

N

E . P

RO

BY

P

AR

K W

AY

12' SEPARATION

WAT-1.0

EXISTING 16" DIP WL

(PN: NONE) 20' MAINTENANCE ROAD

SEE DETAIL SHEET 7

12" GV W/MJR

10+49.76, 0.00'

CONNECT TO EX 16" WL

16"X12" SWIVEL TEE W/CTRB & MJR

0+07.55, 0.00'

16" BV W/ MJR

0+07.54, 5.00' R

16" BV W/ MJR

0+07.55, 4.99' L

EXISTING EDGE OF ASPHALT

EXISTING 16" DIP WL

(PN: NONE)

PR 24" SD X-ING

STA: 4+21.32

PR 30" SD X-ING

STA: 1+07.60

12" GV W/MJR

(0° V DEF)

0+03.40, 0.00'

12" HDC (0.5° V DEF)

4+31.41, 0.00'

22.5° H BEND W/MJR

8+29.79, 0.00'

22.5° H BEND W/MJR

9+74.31, 0.00'PROPOSED 8" SANITARY SEWER - SEE

WASTEWATER PLANS PREPARED BY

ENERTIA CONSULTING GROUP, LLC.

PROPOSED 30" CULVERT -

SEE DE-ICE APRON PLANS

(SHEET C504) PREPARED BY

RS&H, Inc.

EXTEND EXIST 24" SD.

SEE DE-ICE APRON PLANS

(SHEET C504) PREPARED BY

RS&H, Inc.

50' PIC

30' PIC

HORIZONTAL SCALE: 1" = 50'

VERTICAL SCALE: 1" = 5

PROFILE: WAT-1.0 STA: -1+00 TO 11+00

-1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00

20 LF~ 12" WL @ 0.89%

" G

V W

/M

JR

ST

A:

+4

9.7 6,

0.0 0'

T.

O.

P

EL

=6

6.2

CO

NN

EC

T

TO

E

X

" W L

"X

" S

W

IV

EL

T

EE

W

/C

TR

B

MJ

R

ST

A:

-0 +0

7.5 5,

0.0 0'

T.

O.

P

EL

=6

5.7

EXISTING GROUND

@ CL OF PIPE

2'

ASSUMED PROPOSED

GRADE @ CL OF PIPE

PROPOSED STORM CULVERT

(SEE DE-ICE APRON PLANS BY RS&H)

" H

DC

(0

.5° V

D

EF

ST

A:

4+

.41

, 0 .00

T.

O.

P

EL

=6

0.7

75 LF~ 12" WL @ 0.89%

" H

DC

(2

.0° V

D

EF

ST

A:

+6 9.7

6, 0.0

0' T.

O.

P

EL

=6

6.4

400 LF~ 12" WL @ 3.11%

331 LF~ 12" WL @ 0.00%

11 LF~ 12" WL @ 4.63%

" G

V W

/M

JR

(0 ° V

D

EF

ST

A:

0+

.40

, 0 .00

T.

O.

P

EL

=6

5.2

5' MIN

SECONDARY CONTAINMENT PER NOTE 4.

INSTALL PER DETAIL A7-1 OR PROVIDE OTHER

SECONDARY CONTAINMENT (E.G. FLOW FILL).

" H

DC

(2

.7° V

D

EF

ST

A:

0+

.99

, 0 .01

' R T.

O.

P

EL

=6

0.7

STA. 1+07.60

B.O.P. = 6056.87

PR 30" STM X-ING

" G

V W

/ M

JR

ST

A:

5+

.00 , 0

.00

T.

O.

P

EL

=6

1.3

STA. 4+21.32

B.O.P. = 6052.77

PR 24" STM X-ING

69 LF~ 12" WL @ 0.89%

330 LF~ 12" WL @ 0.89%

145 LF~ 12" WL @ 0.89%

.5°

H B

EN

D

W /M

JR

ST

A:

8+

.79

, 0 .00

T.

O.

P

EL

=6

4.2

.5°

H B

EN

D

W /M

JR

ST

A:

9+

.31

, 0 .00

T.

O.

P

EL

=6

5.5

6.1'97 LF~ 12" WL @ 4.63%

PROPOSED STORM CULVERT EXTENSION

(SEE DE-ICE APRON PLANS BY RS&H)

C O

SA

U

SF

S

W A

TE

R

C O

N

ST

R U

C

TI

O N

P

LA

N S

C O

L O

R A

R

I N

G S

C

O L O

R A

D O

D A

T E

N O

A

M E

N D

M E

N T

DATE

SHEET

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

0 1"

OF

COLORADO SPRINGS UTILITIES

WATER CONSTRUCTION PLAN APPROVAL

APPROVAL EXPIRES ONE (1) YEAR FROM THE DATE ABOVE AND RESUBMITTAL OF THESE PLANS FOR REVIEW AND

APPROVAL IS REQUIRED IF CONSTRUCTION DOES NOT BEGIN DURING THIS PERIOD.

02/24/2020

W A

T- 1.

ST

A : 1

1+

+0

FOR BURIED UTILITY INFORMATION

THREE (3) BUSINESS DAYS

BEFORE YOU DIG

CALL 811

(OR 1-800-922-1987)

UTILITY NOTIFICATION

CENTER OF COLORADO (UNCC)

WWW.UNCC.ORG

R

PLAN:

HORIZONTAL SCALE: 1" =

WAT-1.0 STA: -1+00 - 11+00

50' WATER NOTES

1. LOCATION OF EXISTING UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR

TO CONSTRUCTION. DEPTHS AT CONNECTION TO ALL EXISTING WATER LINES

SHALL BE VERIFIED BY THE CONTRACTOR AS A FIRST ORDER OF WORK. THE

CONTRACTOR SHALL REPORT ANY DISCREPANCY TO THE ENGINEER.

2. ALL PIPE LENGTHS SHOWN ARE THREE DIMENSIONAL LENGTHS.

3. PIPE MATERIALS. 12-INCH WATER SHALL BE PVC C900 AND 16-INCH WATER SHALL

BE PVC C905. ALL WATER LOWERINGS SHALL BE DONE WITH THE SAME MATERIAL

SPECIFIED ABOVE.

4. SECONDARY CONTAINMENT SHALL BE BY PLACING A SINGLE JOINT OF PIPE

EXTENDING 9 FEET ON BOTH SIDES OF CROSSING IN ACCORDANCE WITH DETAIL

A7-1. ALTERNATIVELY THE WATER MAIN CAN BE ENCASED IN FLOW FILL, PER THE

SPECIFICATION IN SECTION 4.4.S AND DETAIL A7-6 OF THE CSU WATER STANDARDS,

FOR 9 FEET ON EITHER SIDE OF THE CROSSING, WITH LIMITS EXTENDING TO

6-INCHES BELOW AND ABOVE THE PIPE.

5. FLANGE ELEVATION IS SET 0.4-FT (4-INCH MIN.) ABOVE PROPOSED GRADE.

SURVEYOR SHALL CONFIRM THE FLANGE ELEVATION BEFORE STAKING.

6. DEFLECTIONS SHALL BE AT JOINTS & FITTINGS ONLY AND AS ALLOWED BY CSU. NO

BOWING OF PIPE ALLOWED.

7. CONCRETE THRUST REACTION BLOCKS SHALL BE INSTALLED PER CSU DETAILS

A4-2 AND A4-3 & SPECIFICATIONS.

8. CONCRETE REVERSE ANCHOR (4 TO 16-INCH) SHALL BE INSTALLED PER CSU

DETAILS A7-1, A4-7, A4-8 & SPECIFICATIONS.

M I L

T O

N

E

P

R O

W

Y

M I L

T O

N

E

P

R O

W

Y

A

R

MILTON E. PROBY PKWY

COLORADO SPRINGS

AIRPORT TERMINAL

INTEGRATION

LOOP

C

R

E

S

T

E

R

R

A

P

K

W

Y

EMBRAER

HEIGHTS

KEY MAP

S E

E

S

H E

E T

W A

T

FEB. 24, 2020

MAINTENANCE ACCESS CONTRUCTION NOTES

1. SEE DETAIL SHEET 7 FOR ROAD CROSS-SECTION. ROAD SUBGRADE SHALL BE

EXCAVATED TO PROVIDE THE SECTION SHOWN ON THE DETAIL SHEET.

2. THE FINISHED GRADE OF THE ROAD SHALL MATCH EXISTING GROUND ELEVATIONS

TO THE GREATEST EXTENT POSSIBLE. CONTRACTOR SHALL HAVE THE LENGTH OF

ROAD SURVEYED PRIOR TO CONSTRUCTION.

3. BACKFILL AND COMPACTION OF STORM CULVERT SHALL BE IN ACCORDANCE WITH

COLORADO SPRINGS UTILITIES STANDARD SPECIFICATIONS.

AutoCAD SHX Text 0'

AutoCAD SHX Text 50'

AutoCAD SHX Text 100'

AutoCAD SHX Text 25'

AutoCAD SHX Text

SCALE: 1"=50'

AutoCAD SHX Text N mgackle Snapshot mgackle Text Box mgackle Text Box

S

S

S

S

S

S

S

S

12''W 12''W

12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W

12''W

W

W

W

8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS

S

11+00 12+00 13+00 14+00 15+00 16+00

+0

+0

19+00 20+00 21+00

12' SEPARATION

10 LF -6" PVC FHL

WAT-1.0

20' MAINTENANCE ROAD

SEE DETAIL SHEET 7

PROPOSED 18" STORM

SEE DE-ICE APRON PLANS (SHEET C501)

PREPARED BY RS&H, INC.

EXISTING ACCESS ROAD

12" GV W/MJR

21+70.24, 0.00'

45° H BEND W/MJR

16+56.86, 0.00'

45° H BEND W/MJR

16+42.72, 0.00'

12"X12" TEE W/CTRB

& MJR, ROLLED (<1° DEF)

20+24.73, 0.00'

1+00.00, 0.00' (WAT-2.0)

12" GV W/MJR

20+19.73, 0.00'

12" STUB W/

TEMP BO ASSEMBLY

TIED BACK TO A CRA

INSTALL SJ PLUG W/2" BO

(DTL A2-7)

21+85.24, 0.00'

12"X6" TEE W/CRTB

& MJR (<1° V DEF)

W/6" GV ON FHL

21+75.24, 0.00'

12" GV W/MJR

21+80.24, 0.00'

12" GV W/MJR

20+29.73, 0.00'

45° H BEND W/MJR

18+87.47, 0.00'

12" GV W/MJR

(0.9° V DEF)

15+97.75, 0.00'

FH-1 FULLY RESTRAINED

21+75.24, 10.00' R

FLANGE=6097.2

FG=6096.8

LAT. INV.=6091.0

FF @20 PSI = 2,800 GPM

PRESSURE @ MDD = 123 PSI

BURY DEPTH = 5.3'

PR 18" SD X-ING

STA: 20+14.40

SEE PROF.

PR 18" SD X-ING

STA: 18+23.98

SEE PROF.

PR SS X-ING

STA: 16+10.98

SEE PROF.

PR SS X-ING

STA: 14+39.17

SEE PROF.

SD

18" SD

45° H BEND W/MJR

ROLLED (0.9° V DEF)

19+01.61, 0.00'

8" SS AND STRUCTURES

FROM DE-ICE POND SEE

DE-ICE APRON PLANS

(SHEET C503) PREPARED BY

RS&H, Inc.

PROPOSED 8" SANITARY SEWER - SEE

WASTEWATER PLANS PREPARED BY

ENERTIA CONSULTING GROUP, LLC.

50' PIC

30' PIC

30' PIC

HORIZONTAL SCALE: 1" = 50'

VERTICAL SCALE: 1" = 5

PROFILE: WAT-1.0 STA: 11+00 TO 23+00

11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00

.19

.19

.93

.93

.57

" G

V W

/M

JR

(0 .9°

V D

EF

ST

A:

+9

7.7 5,

0.0 0'

T.

O.

P

EL

=6

0.9

45 LF~ 12" WL @ 0.00%

" G

V W

/M

JR

ST

A:

+8

0.2 4,

0.0 0'

T.

O.

P

EL

=6

1.8

" G

V W

/M

JR

ST

A:

+7

0.2 4,

0.0 0'

T.

O.

P

EL

=6

1.6

° H

B

EN

D W

/M

JR

ST

A:

+4

2.7 2,

0.0 0'

T.

O.

P

EL

=6

0.9

° H

B

EN

D W

/M

JR

ST

A:

+5

6.8 6,

0.0 0'

T.

O.

P

EL

=6

0.9

14 LF~ 12" WL @ 0.00%

° H

B

EN

D W

/M

JR

ST

A:

+8

7.4 7,

0.0 0'

T.

O.

P

EL

=6

0.9

.25

° V B

EN

D

W / M

JR

ST

A:

+0 5.1

9, 0.0

0' T.

O.

P

EL

=6

9.0

15LF~12" WL @ 1.6%

" G

V W

/M

JR

ST

A:

+1

9.7 3,

0.0 0'

T.

O.

P

EL

=6

9.3

" G

V W

/M

JR

ST

A:

+2

9.7 3,

0.0 0'

T.

O.

P

EL

=6

9.4

T.

O.

P

EL

=6

9.4

"X

" T

EE

W

/C

TR

B

MJ

R, R

OL

LE

D

1°

D

EF

ST

A:

+2 4.7

3, 0.0

0' T.

O.

P

EL

=6

9.3

141 LF~ 12" WL @ 1.57%

5 LF~ 12" WL @ 1.57%

5 LF~ 12" WL @ 1.57%

5 LF~ 12" WL @ 1.57%

"X

6" T

EE

W

/C

RT

B

MJ

R

1°

V D

EF

W /6"

G V

ON

F

HL

ST

A:

+7 5.2

4, 0.0

0' T.

O.

P

EL

=6

1.7

T.

O.

P

EL

=6

1.4

CAUTION

THE EXISTING UGT, UGE, UGT AND GAS CROSSINGS HAVE NOT BEEN

POTHOLED. THE CONTRACTOR SHALL POTHOLE THESE CROSSINGS

AS A FIRST ORDER OF WORK AND REPORT THE FINDINGS TO THE

ENGINEER SO THAT THE PLANS CAN BE ADJUSTED AS NEEDED. THE

PLANS WILL NEED TO BE REVISED. NOTE THAT HIGH PRESSURE GAS

LINES WILL REQUIRE A MINIMUM 5-FEET OF CLEARANCE PER CSU

STANDARDS AND CRITERIA.

5' MIN

5' MIN

1.5' MIN

5 LF~ 12" WL @ 1.57%

5 LF~ 12" WL @ 1.57%

LF

~1 2"

W L @

.5%

21 LF~ 12" WL @ 1.57%

.25 ° V

B

EN

D W

/M

JR

ST

A:

+2

2.1 2,

0.0 0'

T.

O.

P

EL

=6

1.2

EXISTING GROUND

@ CL OF PIPE

PROPOSED

GROUND

@ CL OF PIPE

" S

TU

B

W

TE

MP

B O

AS

SE

MB

LY

TI

ED

B

AC

K

TO

A C

RA

IN

ST

AL

L S J P

LU

G

W /2"

B O

(D

TL

A 2-

7)

ST

A:

+8 5.2

4, 0.0

0'

T.

O.

P.

.60

PR

" S D

X-

IN

G

ST

A.

+1 4.4

B.

O.

P.

.40

PR

" S D

X-

IN

G

ST

A.

+2 3.9

" H

DC

(1

.1° V

D

EF

ST

A:

+7 0.0

4, 0.0

0' T.

O.

P

EL

=6

8.8

° H

B

EN

D W

/M

JR

RO

LL

ED

(0

.9° V

D

EF

ST

A:

+0 1.6

1, 0.0

0' T.

O.

P

EL

=6

0.9

14 LF~ 12" WL @ 0.04%

231 LF~ 12" WL @ 0.00%

9.5'

2.3'

T.

O.

P.

.17

PR

8"

S S

X-

IN

G

ST

A.

+3 9.1

2.7'

T.

O.

P.

.51

PR

8"

S S

X-

IN

G

ST

A.

+1 0.9

128 LF~ 12" WL @ 1.60%

400 LF~ 12" WL @ 3.11% SECONDARY CONTAINMENT PER NOTE 4.

INSTALL PER DETAIL A7-1 OR PROVIDE OTHER

SECONDARY CONTAINMENT (E.G. FLOW FILL).

PORTION OF WATERLINE AT SLOPE GREATER

THAN 10% SHALL BE FULLY RESTRAINED.

C O

SA

U

SF

S

W A

TE

R

C O

N

ST

R U

C

TI

O N

P

LA

N S

C O

L O

R A

R

I N

G S

C

O L O

R A

D O

D A

T E

N O

A

M E

N D

M E

N T

DATE

SHEET

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

0 1"

OF

COLORADO SPRINGS UTILITIES

WATER CONSTRUCTION PLAN APPROVAL

APPROVAL EXPIRES ONE (1) YEAR FROM THE DATE ABOVE AND RESUBMITTAL OF THESE PLANS FOR REVIEW AND

APPROVAL IS REQUIRED IF CONSTRUCTION DOES NOT BEGIN DURING THIS PERIOD.

02/24/2020

W A

T- 1.

ST

A : 1

1+

+0

FOR BURIED UTILITY INFORMATION

THREE (3) BUSINESS DAYS

BEFORE YOU DIG

CALL 811

(OR 1-800-922-1987)

UTILITY NOTIFICATION

CENTER OF COLORADO (UNCC)

WWW.UNCC.ORG

R

PLAN:

HORIZONTAL SCALE: 1" =

WAT-1.0 STA: 11+00 - 23+00

50'

M I L

T O

N

E

P

R O

W

Y

M I L

T O

N

E

P

R O

W

Y

A

R

MILTON E. PROBY PKWY

COLORADO SPRINGS

AIRPORT TERMINAL

INTEGRATION

LOOP

C

R

E

S

T

E

R

R

A

P

K

W

Y

EMBRAER

HEIGHTS

KEY MAP

S E

E

S

H E

E T

A

T

FEB. 24, 2020

SEE SHEET 6

WAT-2.0

WATER NOTES

1. LOCATION OF EXISTING UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR

TO CONSTRUCTION. DEPTHS AT CONNECTION TO ALL EXISTING WATER LINES

SHALL BE VERIFIED BY THE CONTRACTOR AS A FIRST ORDER OF WORK. THE

CONTRACTOR SHALL REPORT ANY DISCREPANCY TO THE ENGINEER.

2. ALL PIPE LENGTHS SHOWN ARE THREE DIMENSIONAL LENGTHS.

3. PIPE MATERIALS. 12-INCH WATER SHALL BE PVC C900 AND 16-INCH WATER SHALL

BE PVC C905. ALL WATER LOWERINGS SHALL BE DONE WITH THE SAME MATERIAL

SPECIFIED ABOVE.

4. SECONDARY CONTAINMENT SHALL BE BY PLACING A SINGLE JOINT OF PIPE

EXTENDING 9 FEET ON BOTH SIDES OF CROSSING IN ACCORDANCE WITH DETAIL

A7-1. ALTERNATIVELY THE WATER MAIN CAN BE ENCASED IN FLOW FILL, PER THE

SPECIFICATION IN SECTION 4.4.S AND DETAIL A7-6 OF THE CSU WATER STANDARDS,

FOR 9 FEET ON EITHER SIDE OF THE CROSSING, WITH LIMITS EXTENDING TO

6-INCHES BELOW AND ABOVE THE PIPE.

5. FLANGE ELEVATION IS SET 0.4-FT (4-INCH MIN.) ABOVE PROPOSED GRADE.

SURVEYOR SHALL CONFIRM THE FLANGE ELEVATION BEFORE STAKING.

6. DEFLECTIONS SHALL BE AT JOINTS & FITTINGS ONLY AND AS ALLOWED BY CSU. NO

BOWING OF PIPE ALLOWED.

7. CONCRETE THRUST REACTION BLOCKS SHALL BE INSTALLED PER CSU DETAILS

A4-2 AND A4-3 & SPECIFICATIONS.

8. CONCRETE REVERSE ANCHOR (4 TO 16-INCH) SHALL BE INSTALLED PER CSU

DETAILS A7-1, A4-7, A4-8 & SPECIFICATIONS.

MAINTENANCE ACCESS CONTRUCTION NOTES

1. SEE DETAIL SHEET 7 FOR ROAD CROSS-SECTION.

2. THE FINISHED GRADE OF THE ROAD SHALL MATCH EXISTING GROUND ELEVATIONS

TO THE GREATEST EXTENT POSSIBLE. CONTRACTOR SHALL HAVE THE LENGTH OF

ROAD SURVEYED PRIOR TO CONSTRUCTION AND SHALL PAY PARTICULAR

ATTENTION TO THE ALIGNMENT ACROSS THE TOP OF POND, INCLUDING THE

EMERGENCY SPILLWAY.

3. THE EMERGENCY SPILLWAY SHALL BE INSTALLED TO THE INTENT OF THE INITIAL

DESIGN, INCLUDING BOTTOM AND TOP ELEVATION AND MINIMUM WIDTH. THE SIDE

SLOPES MAY NEED TO BE FLATTENED IN ORDER TO PROVIDE A DRIVABLE

SURFACE. AGAIN, THE CONTRACTOR SHALL SURVEY THIS EXISTING FEATURE AND

PROVIDE THE INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION.

4. ROAD SUBGRADE SHALL BE EXCAVATED TO PROVIDE THE SECTION SHOWN ON

THE DETAIL SHEET.

5. BACKFILL AND COMPACTION OF STORM CULVERT SHALL BE IN ACCORDANCE WITH

COLORADO SPRINGS UTILITIES STANDARD SPECIFICATIONS.

AutoCAD SHX Text 0'

AutoCAD SHX Text

AutoCAD SHX Text 100'

AutoCAD SHX Text 25'

AutoCAD SHX Text

SCALE: 1"=50'

AutoCAD SHX Text N mgackle Snapshot mgackle Text Box mgackle Text Box

45° H BEND W/MJR

16+42.72, 0.00'

2+00 3+00 4+00

5+00 6+00 7+00 8+00

12" GV W/MJR

1+05.00, 0.00'

12" GV W/MJR

8+17.41, 0.01' R

16" BV W/ MJR

8+22.42, 5.00' R

CONNECT TO EX 16" WL

16"X12" SWIVEL TEE W/CTRB & MJR

8+22.41, 0.00'

16" BV W/ MJR

8+22.41, 5.00' L

10.4'

O

LD

D

RE

N N

AN

RO

AD

2+00 3+00 4+00

5+00 6+00 7+00 8+00 2+00

3+00 4+00

5+00 6+00 7+00 8+00 2+00

3+00 4+00

5+00 6+00 7+00 8+00 2+00

3+00 4+00

5+00 6+00 7+00 8+00 2+00

3+00 4+00

5+00 6+00 7+00 8+00 2+00

3+00 4+00

5+00 6+00 7+00 8+00 2+00

3+00 4+00

5+00 6+00 7+00 8+00 2+00

3+00 4+00

5+00 6+00 7+00 8+00 1+00 2+00

3+00 4+00

5+00 6+00 7+00 8+00 EX 16" DIP WL

(PN: NONE)

EX 16" DIP WL

(PN: NONE)

WAT-2.0

12" HDC (2.8° V DEF)

6+74.63, 0.00'

12"X12" TEE W/CTRB

& MJR, ROLLED (<1° DEF)

20+24.73, 0.00'

1+00.00, 0.00' (WAT-2.0)

12" GV W/MJR

(<1° V DEF)

4+66.03, 0.00'

PROPOSED EDGE

OF PAVEMENT

12"X6" TEE W/CRTB

& MJR (<1° V DEF)

W/6" GV ON FHL

5+17.98, 0.00'

FH-2 FULLY RESTRAINED

5+17.95, 16.47' L

FLANGE=6094.6

FG=6094.1

LAT. INV.=6085.9

FF @20 PSI = 3,000 GPM

PRESSURE @ MDD = 125 PSI

BURY DEPTH = 7.7'

16 LF -6" PVC FHL

WAT-2.0

1" SADDLE TAP

SEE NOTE 1

3+25.91, 0.00'

2" SADDLE TAP

SEE NOTE 1

5+12.19, 0.00'

12"X6" TEE W/ CRTB &

MJR (SEE NOTE 1)

2+71.23, 0.00'

W

AT

-1 .0

W

AT

-1 .0

" R

CP

S

D

18" SD

" R

CP

S

D

12" 45° H BEND W/MJR

2+81.10, 0.00' 12" 45° H BEND W/MJR

4+21.49, 0.00' 12" 45° H BEND W/MJR

4+45.61, 0.00'

15' WL-BLDG

12" 45° H BEND W/MJR

2+89.80, 0.00'

24.5' PVMT

24' PVMTBUILDING1

W

W

12''W 12''W

12''W

12''W 12''W 12''W 12''W 12''W

PROPOSED SS SVC LINE.

RE: CIVIL PLANS

PREPARED BY RPA.

PROPOSED 15" ARCH RCP. RE: SHEET CU201

CIVIL PLANS PREPARED BY RPA.

PROPOSED STORM

RE:DE-ICE APRON

PLANS BY RS&H

6" FIRE LINE. SEE SHEETS

CU403-CU404 WATER

PLANS BY RPA.

PR 15" ARCH RCP X-ING

STA: 7+86.62

PR 36" SD X-ING

STA: 2+58.94

30' PIC

30' PIC

EX 50' PIC (APPROX)

FIMS#800171 (MAY 1, 2006)

HORIZONTAL SCALE: 1" = 50'

VERTICAL SCALE: 1" = 5

PROFILE: WAT-2.0 STA: 0+00 TO 9+00

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00

.99

.75

.50

.55

.31

.06

.81

.14

.93

.73

.20

"X

" T

EE

W

/C

TR

B

MJ

R, R

OL

LE

D

1°

D

EF

ST

A:

+2 4.7

3, 0.0

0' T.

O.

P

EL

=6

9.3

T.

O.

P

EL

=6

9.3

" G

V W

/M

JR

ST

A:

1+

.00 , 0

.00

T.

O.

P

EL

=6

9.3

157LF~12" WL @ 0.58%

" H

DC

(2

.8° V

D

EF

ST

A:

6+

.63

, 0 .00

T.

O.

P

EL

=6

5.7

" G

V W

/M

JR

ST

A:

+3

5.2 4, 7.8

0' R

T.

O.

P

EL

=6

8.1

5LF~12" WL @ 5.32%

CO

NN

EC

T

TO

E

X

" W L

"X

" S

W

IV

EL

T

EE

W

/C

TR

B

MJ

R

ST

A:

8+

.41 , 0

.00

T.

O.

P

EL

=6

7.8

T.

O.

P

EL

=6

8.0

143LF~12" WL @ 5.32%

5' MIN

EXISTING GROUND

@ CL OF PIPE

2.8'

5LF~12" WL @ 0.66%

PROPOSED GROUND

@ CL OF PIPE

T.

O.

P.

.46

PR

" S D

X-

IN

G

ST

A.

2+

.94

" G

V W

/M

JR

1°

V D

EF

ST

A:

4+

.03 , 0

.00

T.

O.

P

EL

=6

6.9

6LF~12" WL @ 0.58%

"X

6" T

EE

W

/C

RT

B

MJ

R

1°

V D

EF

W /6"

G V

ON

F

HL

ST

A:

5+

.98

, 0 .00

T.

O.

P

EL

=6

6.6

T.

O.

P

EL

=6

6.4

20LF~12" WL @ 0.66%

" 4

5° H

B

EN

D W

/M

JR

ST

A:

4+

.61 , 0

.00

T.

O.

P

EL

=6

7.0

" 4

5° H

B

EN

D W

/M

JR

ST

A:

4+

.49 , 0

.00

T.

O.

P

EL

=6

7.2

96LF~12" WL @ 0.66%

1" S

AD

DL

E

TA

P

SE

E

NO

TE

ST

A:

3+

.91 , 0

.00

T.

O.

P

EL

=6

7.8

T.

O.

P

EL

=6

7.5

36LF~12" WL @ 0.66%

" 4

5° H

B

EN

D W

/M

JR

ST

A:

2+

.80 , 0

.00

T.

O.

P

EL

=6

8.1

" 4

5° H

B

EN

D W

/M

JR

ST

A:

2+

.10 , 0

.00

T.

O.

P

EL

=6

8.1

10LF~12" WL @ 0.66%

"X

6" T

EE

W

/ C

RT

B

MJ

R

(S

EE

N

OT

E 1)

ST

A:

2+

.23 , 0

.00

T.

O.

P

EL

=6

8.2

166LF~12" WL @ 0.66%

24LF~12" WL @ 0.66%

2" S

AD

DL

E

TA

P

SE

E

NO

TE

ST

A:

5+

.19 , 0

.00

T.

O.

P

EL

=6

6.6

46LF~12" WL @ 0.58%

9LF~12" WL @ 0.66%

2.6'

B.

O.

P.

.37

PR

" A

RC

H

RC

P X-

IN

G

ST

A.

7+

.85

SECONDARY CONTAINMENT PER NOTE 5.

INSTALL PER DETAIL A7-1 OR PROVIDE OTHER

SECONDARY CONTAINMENT (E.G. FLOW FILL).

C O

SA

U

SF

S

W A

TE

R

C O

N

ST

R U

C

TI

O N

P

LA

N S

C O

L O

R A

R

I N

G S

C

O L O

R A

D O

D A

T E

N O

A

M E

N D

M E

N T

DATE

SHEET

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

0 1"

OF

COLORADO SPRINGS UTILITIES

WATER CONSTRUCTION PLAN APPROVAL

APPROVAL EXPIRES ONE (1) YEAR FROM THE DATE ABOVE AND RESUBMITTAL OF THESE PLANS FOR REVIEW AND

APPROVAL IS REQUIRED IF CONSTRUCTION DOES NOT BEGIN DURING THIS PERIOD.

02/24/2020

W A

T- 2.

ST

A : 0

+0

TO

+0

FOR BURIED UTILITY INFORMATION

THREE (3) BUSINESS DAYS

BEFORE YOU DIG

CALL 811

(OR 1-800-922-1987)

UTILITY NOTIFICATION

CENTER OF COLORADO (UNCC)

WWW.UNCC.ORG

R

PLAN:

HORIZONTAL SCALE: 1" =

WAT-2.0 STA: 0+00 TO 9+00

50'

WATER NOTES

1. SEE SHEET C403 WATER SITE PLAN PREPARED BY RPA FOR CONTINUATION OF

WATER SERVICE TAPS AND FIRE LINE EXTENSIONS INTO THE SITE. WATER TAPS

SHALL COMPLY WITH COLORADO SPRINGS UTILITIES DETAILS B1-3.

2. LOCATION OF EXISTING UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR

TO CONSTRUCTION. DEPTHS AT CONNECTION TO ALL EXISTING WATER LINES

SHALL BE VERIFIED BY THE CONTRACTOR AS A FIRST ORDER OF WORK. THE

CONTRACTOR SHALL REPORT ANY DISCREPANCY TO THE ENGINEER.

3. ALL PIPE LENGTHS SHOWN ARE THREE DIMENSIONAL LENGTHS.

4. PIPE MATERIALS. 12-INCH WATER SHALL BE PVC C900 AND 16-INCH WATER SHALL

BE PVC C905. ALL WATER LOWERINGS SHALL BE DONE WITH THE SAME MATERIAL

SPECIFIED ABOVE.

5. SECONDARY CONTAINMENT. WATER MAIN SHALL BE ENCASED IN FLOW FILL, PER

THE SPECIFICATION IN SECTION 4.4.S AND DETAIL A7-6 OF THE CSU WATER

STANDARDS, FOR 9 FEET ON EITHER SIDE OF THE CROSSING, WITH LIMITS

EXTENDING TO 6-INCHES BELOW AND ABOVE THE PIPE.

6. FLANGE ELEVATION IS SET 0.4-FT (4-INCH MIN.) ABOVE PROPOSED GRADE.

SURVEYOR SHALL CONFIRM THE FLANGE ELEVATION BEFORE STAKING.

7. DEFLECTIONS SHALL BE AT JOINTS & FITTINGS ONLY AND AS ALLOWED BY CSU. NO

BOWING OF PIPE ALLOWED.

8. CONCRETE THRUST REACTION BLOCKS SHALL BE INSTALLED PER CSU DETAILS

A4-2 AND A4-3 & SPECIFICATIONS.

M I L

T O

N

E

P

R O

W

Y

M I L

T O

N

E

P

R O

W

Y

A

R

MILTON E. PROBY PKWY

COLORADO SPRINGS

AIRPORT TERMINAL

INTEGRATION

LOOP

C

R

E

S

T

E

R

R

A

P

K

W

Y

EMBRAER

HEIGHTS

KEY MAP

SEE SHEET 5

WAT 1.0

SEE SHEET 5

WAT 1.0

FEB. 24, 2020

AutoCAD SHX Text

SSS

AutoCAD SHX Text 0'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1"=50'

AutoCAD SHX Text N

AutoCAD SHX Text N mgackle Snapshot mgackle Text Box mgackle Text Box mgackle CSU Water Approval

GirtenA Cloud

GirtenA Cloud

GirtenA Cloud

GirtenA PolyLine

GirtenA Text Box 2 5/28/20 Remove 6" Fire line, 1" and 2" Domestic Services, and FH-2

GirtenA PolyLine

GirtenA PolyLine

GirtenA PolyLine

GirtenA Text Box

GirtenA Text Box

GirtenA Text Box

GirtenA Text Box Addendum #2 2 Sanitary Sewer Project No. 2019-S086 Water Project No. 2019-W185 Sheets 3 and 6 are provided as Addendum #2 to remove the proposed 6" Fire line, 1" Domestic Line, 2" Domestic Line, Fire Hydrant #2 and all associated valves and fittings from this project scope of work. These items will be constructed as part of the USFS Airtanker Base plans to be submitted by Robert Peccia & Associates Inc. (RPA) at a later date.

TE

R

D

ET

A

IL

S

NOTE: CONTRACTOR SHALL REFER TO THE CURRENT COLORADO SPRINGS UTILITIES WATER LINE EXTENSION AND SERVICE

STANDARDS MANUAL. APPLICABLE DETAILS, STANDARDS AND SPECIFICATIONS INCLUDE BUT ARE NOT LIMITED TO THE ABOVE

REFERENCED ITEMS.

WATER DETAILS

ITEM MUNICIPALITY SHEET NO.

TEMPORARY BLOW-OFF ASSEMBLIES -12" & LARGER COLORADO SPRINGS UTILITIES A2-7

CONCRETE THRUST REACTION BLOCK (16" & SMALLER)

RESTRAINED PIPE LENGTH W/MJ RESTRAINTS

VALVE & FITTINGS W/MJ JOINT RESTRAINTS

A4-2, -3

A4-4

A4-5

BEND CONFIGURATIONS & RESTRAINTS A4-6

CONCRETE REVERSE ANCHOR (16" & SMALLER) A4-7, -8

AIR AND VACUUM VALVE STATION A6-10

VALVE BOX INSTALLATION A9-1

N.T.S.

STANDARD DETAILS LIST1

LOWERING DETAIL UTILITY CROSSING 30" & SMALLER A7-1

LOWERING WITH HIGH DEFLECTION COUPLINGS A7-9

NTS

MAINTENANCE ROAD

TYPICAL SECTION

COLORADO SPRINGS UTILITIES

COLORADO SPRINGS UTILITIES

COLORADO SPRINGS UTILITIES

COLORADO SPRINGS UTILITIES

COLORADO SPRINGS UTILITIES

COLORADO SPRINGS UTILITIES

COLORADO SPRINGS UTILITIES

COLORADO SPRINGS UTILITIES

COLORADO SPRINGS UTILITIES

16' MIN. MAINTENANCE & ACCESS ROAD

COMPACTED CDOT CLASS 5 OR CLASS 6

AGGREGATE BASE COURSE

GEOTEXTILE

PROPERLY MOISTURE

CONDITION MATERIALS

COMPACTED FIRM SUBGRADE

10-INCHES*

8-INCHES*

* REQUIRED MINIMUM THICKNESS SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER

FOR THE ROADWAY PAVEMENT DESIGN TO PROVIDE HS-20 LOADING CAPACITY.

FIRE HYDRANT LOCATION & INSTALLATION A5-1, -2, -3COLORADO SPRINGS UTILITIES

NTS

CONCRETE THRUST REACTION BLOCK

TYPICAL DETAIL

NTS

CONCRETE REVERSE ANCHOR

TYPICAL DETAIL

LOWERING DETAIL W/CASING UTILITY CROSSING > 30" A7-2COLORADO SPRINGS UTILITIES

TYPICAL STEEL CASING INSTALLATION A7-3COLORADO SPRINGS UTILITIES

TYPICAL STEEL CASING INSTALLATION A7-4COLORADO SPRINGS UTILITIES

C O

SA

U

SF

S

W A

TE

R

C O

N

ST

R U

C

TI

O N

P

LA

N S

C O

L O

R A

R

I N

G S

C

O L O

R A

D O

D A

T E

N O

A

M E

N D

M E

N T

DATE

SHEET

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

0 1"

OF

02/24/2020

FEB. 24, 2020

2' SHOULDER2' SHOULDER

Sheets and Views
1 CVR-1.0
2 GEN-2.0
3 OUP-3.0
4 WAT-4.0
5 WAT-4.1
6 WAT-4.2
7 DTL-5.0

File details come from the government source that posted it. Updated .