Drawings_Part_7_2018_06-01.pdf

PDF 1 MB Posted

Attached to
INRC - Phase III
Solicitation number
12034318R0017
Issued by

About this file

This notice provides details for a planned construction contract award by the U.S. Forest Service Northern Region. The contract is for Phase III of the Interagency Natural Resource Center in Coeur d'Alene, Idaho, which will include a 29,000 square foot main office building supporting 173 employees from the U.S. Fish & Wildlife Service, Bureau of Land Management, and Forest Service. The project value is estimated between $5 million and $10 million. The solicitation is expected to be posted on or around June 5, 2018 with responses due 30 days after. The notice provides advance visibility on an upcoming opportunity for firms in the federal construction sector.

17 - J-3 Drawings Part 7

View the file

Other files

File Type Posted
INRC_Second_Floor.dwg DWG drawing
7-12-18_Q&A.XLSX XLSX spreadsheet
INRC_First_Floor.dwg DWG drawing
Amendment_0002.pdf PDF
Revised_B-1.pdf PDF
Questions_and_Answers_062918.pdf PDF
L1.5_(rev1).pdf PDF
Amendment_0001.pdf PDF
CV_(rev1).pdf PDF
125900_SF_-_SYSTEMS_FURNITURE.pdf PDF
S0.1_(rev1).pdf PDF
C1.3_(rev1).PDF PDF
Prebid_Notes_6-19-18.pdf PDF
Prebid_Attendance.pdf PDF
Questions_and_Answers_061818.pdf PDF
Part_2_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_1_2018_06-01.pdf PDF
Drawings_Part_13_2018_06-01.pdf PDF
Drawings_Part_6_2018_06-01.pdf PDF
Drawings_Part_9_2018_06-01.pdf PDF
Drawings_Part_3_2018_06-01.pdf PDF
Part_5_Project_Manual_2018_06_01.pdf PDF
Part_6_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_8_2018_06-01.pdf PDF
J-1_Wage_Rate_Decision_ID180031_Mod_3_Dated_05112018.pdf PDF
Drawings_Part_10_2018_06-01.pdf PDF
Drawings_Part_14_2018_06-01.pdf PDF
Drawings_Part_12_2018_06-01.pdf PDF
J-5_Past_Performance_Questionnaire.pdf PDF
Part_4_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_4_2018_06-01.pdf PDF
Drawings_Part_5_2018_06-01.pdf PDF
Drawings_Part_2_2018_06-01.pdf PDF
Drawings_Part_11_2018_06-01.pdf PDF
Short_Set_Solicitation_12034318R0017_Final_06072018.pdf PDF
J-4_State_of_Idaho_Workers'_Insurance.pdf PDF
Part_3_Project_Manual_2018_06_01.pdf PDF
Solicitation_12034318R0017_Final_06072018.pdf PDF
Part_7_Project_Manual_2018_06_01.pdf PDF
Part_1_Project_Manual_2018_06_01.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A9.13

A9.13

A9.13

WP-1

S1

SW-1 S2

A9.13

WP-1

SW-1

A9.13

A9.13

A9.13

WP-1

S1

SIM.

SIM.

MAP/ BROCHURE STORAGE,

CENTER ON WALL

3'

2"

3' - 0"

NS-1

A9.7

LINEAR LIGHT, SEE ELECTRICAL

WB - 3

SW-1

WP-1WP-1

A9.13

A9.13

WP-1

S1 S3

A9.13

A9.13

11 SIM.

WALL BADGES

(USFS, USFW, BLM)

REF. SPEC.

WB - 3

WG-1

REF.

WP-3WP-1

A9.4

A9.4

A9.4

A9.4

/9 A9.8

WW-2 WRAPS CORNER

AND EXTENDS BEYOND

CASEWORK REF. /10 A9.4

14' - 5 1/4"6"

WW-2

OPEN TO

RESTROOM

VESTIBULE

WATER FOUNTAIN /

BOTTLE FILLING STATION

WB - 3

WP-1 WP-1 WP-1

A9.4

A9.4

A9.4

A9.4

A9.4

9 WW-2

WP-3

ENTRY TO BATHROOMS

TO BE PAINTED WITH

WP-3 REF. /7 A9.9

ALIGN END GRAIN VENEER

@ THE TOP OF THE DOOR

FRAME DO NOT NOTCH

END GRAIN PIECES

WRAP DOUG FIR TRIM

AROUND ENTIRE DOOR

FRAME

WB - 3

NS-1

WP-1WP-1WP-1

2' - 5 1/2"

WW-2

TYP.

2"

2"

WRAP END GRAIN

WD BLOCKING

AROUND CORNER AT

ADA DESK REF.

MAKE THE ROW OF END GRAIN

VENEER @ INTERSECTION W/ ADA

DESK AT SIMILAR HEIGHT TO THE

RESILIENT SURFACE, CF-4

E Q

E Q

/12 A9.4

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.1

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.1A2.1

1 101 ENTRY VEST. - NORTH

: 1/4" = 1'-0"A6.1A2.1

2 101 ENTRY VEST. - EAST

: 1/4" = 1'-0"A6.1A2.1

3 101 ENTRY VEST. - SOUTH

: 1/4" = 1'-0"A6.1A2.1

4 101 ENTRY VEST. - WEST

: 1/4" = 1'-0"A6.1A2.1

5 102 LOBBY - NORTH

: 1/4" = 1'-0"A6.1A2.1

7 102 LOBBY - EAST

: 1/4" = 1'-0"A6.1A2.1

9 102 LOBBY - SOUTH

: 1/4" = 1'-0"A6.1A2.1

11 102 LOBBY - WEST

3'

12' - 0"

4'

AC-4

NS-1

EQ. EQ.

WB-3

WP-1

WB - 3

WP-1

A9.5

2' - 4" 2' - 4" 3"

2' - 4" 2' - 4" 3"

A9.5

3'

1'

3'

WB-3

WP-1

WP-1

WB-1

A9.13

A9.13

13S3

2"

8" 8"10 1/2"

5'

1'

WALL BADGES (USFS, USFW, BLM)

HEIGHT 15" CLEAR, CAST ANODIZED

ALUMINUM REF. SPEC.

WP-3WP-1

WB-1

/2 A9.7

WG-1

REF.

WP-3

CREATE SEAMLESS WRAP

OF WALL GRAPHIC

AROUND CORNER

/8 A9.8

WP-1

WB-1 OPEN OPEN

2' - 4" 2' - 4"

2 3/4"

3' - 2" 4" 2' - 4" 5' - 11 1/4" 2' - 4"

4"

A9.5

A9.4

A9.4

A9.4

3'

WB-1

CASEWORK

FILLER TYP.

6"

2'

OPEN

TO

LOBBY3'

1'

3'

WP-1

A9.5

WORK SURFACE BRACKET,

RIGID STEEL MOUNTED TO

TRIMBOARD LEDGER TYP.

WP-1

WB-1

4" 2' - 4" 3' - 0" 1' - 6" 2' - 4"

3' - 0" 2' - 4" 3' - 0"4"

A9.5

WP-1A9.5

A9.5

A9.5

A9.5

CASEWORK FILLER PANEL

CASEWORK FILLER PANEL

WB-1

3'

1'

3'

5' - 0" 3" 5' - 0"

2' - 4" 2' - 4" 2' - 4" 2 1/2"

A9.5

12WP-1

EQ. EQ.

3'

4" 3'

WB-1

CASEWORK FILLER PANEL

WP-1

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.2

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.2A2.1

10 104 MEDIUM CONFERENCE ROOM - EAST

: 1/4" = 1'-0"A6.2A2.1

9 104 MEDIUM CONFERENCE ROOM - NORTH

: 1/4" = 1'-0"A6.2A2.1

11 104 MEDIUM CONFERENCE ROOM - SOUTH

: 1/4" = 1'-0"A6.2A2.1

12 104 MEDIUM CONFERENCE ROOM - WEST

: 1/4" = 1'-0"A6.2A2.1

1 103 RECEPTION - NORTH

: 1/4" = 1'-0"A6.2A2.1

2 103 RECEPTION - EAST

: 1/4" = 1'-0"A6.2A2.1

3 103 RECEPTION - SOUTH

: 1/4" = 1'-0"A6.2A2.1

4 103 RECEPTION - WEST

: 1/4" = 1'-0"A6.2A2.1

5 103A MAIL ROOM - NORTH

: 1/4" = 1'-0"A6.2A2.1

6 103A MAIL ROOM - EAST

: 1/4" = 1'-0"A6.2A2.1

7 103A MAIL ROOM - SOUTH

: 1/4" = 1'-0"A6.2A2.1

8 103A MAIL ROOM - WEST

AC-2

WG-1

REF.

WG-1

REF.

OPEN TO

PARTITION

STORAGE

WP-1 WP-1

A6.3

/12 A9.8 /12 A9.8

WB - 1WB - 1

S4

WP-1

24' - 1 3/4"

A9.13

A9.13

A9.13

WOOD SILL AT BASE OF

STOREFRONT REF. /10 A9.13

S4

TYP.

3/4"

3' - 4" 3' - 4" 3' - 0" 3' - 4" 3' - 4" 3' - 4" 4"

3' - 4" 3' - 4" 3' - 0" 3' - 4" 3' - 4" 3' - 4" 4"

A9.5

A9.5

A9.5

A9.5

UPPER CASE WORK FLUSH

W/ACT CEILING EITHER SIDE

WP-3

WB-1

WP-3CASEWORK FILLER

PANEL BOTH SIDES

AC-3

AC-23'

6'

/4

/4

12' - 2" 1' - 4 1/2" 10' - 11 1/2" 6"

AC-3

WP-1WP-1 WP-1

WB-1

ALIGN

WB-1

WP-1

WB-1

SEEM IN SURFACE

4'

1'

1"

S5

A6.3

A6.3

A9.13

A9.13

AC-2

4:3

ASPECT

RATIO

4:3

ASPECT

RATIO

7' - 6" 7' - 0" CENTERLINE OF PROJECTOR

S5

WOOD SILL AT BASE OF

STOREFRONT REF. /10 A9.13

3/ 4"

3/ 4"

SCHEDULED PARTITION

3/4" x 1 1/4" WOOD TRIM

AC-3 DIRECTLY APPLIED

TO FACE OF PARTITION

3/4" x 2 1/2" WD MARKER

TRAY W/ 3 EQ. 1/8" DEEP

GROOVES TERMINATING

2" FROM EACH END

3/4" x 3/4" TRIM

1/4" 1/4"

1 1/4"

3/ 4"

4' -6

FOLDING PARTITION WALL

REF:

STRUCTURAL STEEL BEAM,

SEE STRUCTURAL

/11 A7.1

ACT CEILING

SOUND BATT INSULATION

1' - 8 1/4"

5/8" GWB

EITHER SIDE

FINISH CEILING

10' - 0"

MFGR RECOMMENDED

TRACK SYSTEM

7 1/4"

4 1/2"

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.3

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.3A2.1

3 105 LARGE MEETING ROOM - EAST

: 1/4" = 1'-0"A6.3A2.1

1 105 LARGE MEETING ROOM - NORTH

: 1/4" = 1'-0"A6.3A2.1

5 105 LARGE MEETING ROOM - SOUTH

: 1/4" = 1'-0"A6.3A2.1

7 105 LARGE MEETING ROOM - WEST

: 3" = 1'-0"A6.3A6.3

12 WHITE BOARD - WALL COVERING DETAIL

: 3" = 1'-0"A6.3A6.3

14 PARTITION WALL - SECT. DTL @ HEAD

WP-1

FOR TILE PATTERN

AND CORNERING

REF. TYP./6 A9.7

TA-3

TA-11

WP-1

A9.5

14 TYP.

8" 1' - 6" 1' - 0" 1' - 6"

TA-6

TA-7

TA-8

TA-8

TA-8

TA-3

TA-11 TA-4

WP-1

TA-6

TA-7

TA-4 TA-11

WP-1

TA-1

TA-2

TA-10

9" 1' - 6"

FIXED ADA

TILT FRAME

TA-8

WP-1

TA-3

TA-11

WP-1

TA-1

TA-2

TA-10

TA-12

FIXED ADA

TILT FRAME

TA-8

1' - 6" 9"

WP-1

TA-6

TA-7

TA-4

TA-5

TA-11

WP-1

TA-6

TA-7

TA-8

TA-8 TA-8

TA-3

TA-11TA-4

TA-5

C L

NOTES:

1) SUBMIT ACCESSORIES FOR REVIEW

2) ALL TOILET ROOM FIXTURES AND ACCESSORIES TO BE ADA COMPLIANT.

3) PROVIDE BLOCKING FOR ACCESSORY MOUNTING

4) DIMENSIONS REFER TO BOTH FLOOR AND WALL MOUNTED TOILETS. ALL DIMENSIONS ARE

FINISH UNLESS OTHERWISE NOTED

40"

54"

42"

18"

M A

X

"8" MIN

2' - 0" TYP

CLR.

48"

TA-7 TA-6

TA-7

TA-6

TA-8

TA-5

TA-11

TA-9

TA-5 TA-10TA-4

33"

4"

FRP

(2 SIDES)

TA-21

/1 6"

24"

24"

M A

X

TA-3

TA-2 TA-121' - 6"

TA-8

TA-6

TOILET ACCESSORIES & TYPICAL MOUNTING HEIGHTS

SEE PLUMBING DRAWINGS

TOILET PARTITION

FIRE EXTINGUISHER

CABINET

TA-1

M A

X

M A

X

TOILET ACCESSORIES

TA-1 = WASTE RECEPTACLE W/ PAPER TOWEL DISPENSER

TA-2 = WARM-AIR ELECTRIC DRYERS

TA-3 = FOAMING-SOAP DISPENSER

TA-4 = TOILET TISSUE DISPENSER

TA-5 = SANITARY NAPKIN DISPOSAL UNIT

TA-6 = HORIZONTAL GRAB BAR, 36" LONG

TA-7 = VERTICAL GRAB BAR, 18" LONG

TA-8 = SEAT-COVER DISPENSER

TA-9 = MIRROR UNIT - SIZE PER ELEVATION

TA-10 = DIAPER-CHANGING STATION

TA-11 = UNDERLAVATORY GUARD

TA-12 = not used

TA-13 = TOILET PARTITION HOOKS, STAINLESS STEEL (TYP. EVERY STALL)

TA-14 = MOP & BROOM HOLDER

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.4

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.4A2.1

1 108 MENS PUBLIC RESTROOM - NORTH

: 1/4" = 1'-0"A6.4A2.1

2 108 MENS PUBLIC RESTROOM - EAST

: 1/4" = 1'-0"A6.4A2.1

3 108 MENS PUBLIC RESTROOM - SOUTH

: 1/4" = 1'-0"A6.4A2.1

4 108 MENS PUBLIC RESTROOM - WEST

: 1/4" = 1'-0"A6.4A2.1

5 109 WOMENS PUBLIC RESTROOM - NORTH

: 1/4" = 1'-0"A6.4A2.1

6 109 WOMENS PUBLIC RESTROOM - EAST

: 1/4" = 1'-0"A6.4A2.1

7 109 WOMENS PUBLIC RESTROOM - SOUTH

: 1/4" = 1'-0"A6.4A2.1

8 109 WOMENS PUBLIC RESTROOM - WEST

A9.5

WP-1

WW-1

REF.

/11 A9.8

WB-1

ELEVATOR DOOR

WG-1

REF.

/7 A9.8

WB-1

WP-1 /11 A9.8

WW-1

REF.

WB-1

3'

EQ. EQ.12' - 0"

4'

WP-1

AC- 4

WB-1

WP-2WP-2

WB-1

WP-2

WP-1

WB-1

WP-1

WB-1

WP-1

WB-1

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.5

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.5A2.1

1 113B CORRIDOR - NORTH

: 1/4" = 1'-0"A6.5A2.1

3 113B CORRIDOR - WEST

: 1/4" = 1'-0"A6.5A2.1

5 113 D CORRIDOR - SOUTH

: 1/4" = 1'-0"A6.5A2.1

10 114 MEDIUM CONFERENCE ROOM - EAST

: 1/4" = 1'-0"A6.5A2.1

2 113B CORRIDOR - EAST

: 1/4" = 1'-0"A6.5A2.1

9 114 MEDIUM CONFERENCE ROOM - NORTH

: 1/4" = 1'-0"A6.5A2.1

12 114 MEDIUM CONFERENCE ROOM - SOUTH

: 1/4" = 1'-0"A6.5A2.1

11 114 MEDIUM CONFERENCE ROOM - WEST

WP-1 WP-1WP-1

WB-1

WP-1

WB-1

8' - 0"

6'

"FMO MAP AREA

OWNER SUPPLIED

N.I.C.

1'

WP-1

WP-1

WB-1

3' - 0" 3' - 0" 3' - 0" 6"

4'

A9.5

WP-1

WB-1

WP-1

WB-1

4'

" 6" 3' - 0" 3' - 0" 3' - 0"

A9.5

WP-1

WB-1

WC-1

8'

1'

4' - 0"EQ. EQ.

WP-1

TYP.

A9.7

WB-1

WC-1

6' - 0"

8'

1'

EQ. EQ.

WP-1

WB-1

WC-1

8'

4' - 0"

1'

EQ. EQ.

WP-1

WB-1

WC-1

10' - 0"

8'

1'

EQ. EQ.

WP-1

WB-1

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.6

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.6A2.1

6 123 FMO OPEN OFFICE - EAST

: 1/4" = 1'-0"A6.6A2.1

5 123 FMO OPEN OFFICE - NORTH

: 1/4" = 1'-0"A6.6A2.1

7 123 FMO OPEN OFFICE - SOUTH

: 1/4" = 1'-0"A6.6A2.1

8 123 FMO OPEN OFFICE - WEST

: 1/4" = 1'-0"A6.6A2.1

9 125 BLM STG. - NORTH

: 1/4" = 1'-0"A6.6A2.1

10 125 BLM STG. - EAST

: 1/4" = 1'-0"A6.6A2.1

11 125 BLM STG. - SOUTH

: 1/4" = 1'-0"A6.6A2.1

12 125 BLM STG. - WEST

: 1/4" = 1'-0"A6.6A2.1

1 121 PRIVACY ROOM - NORTH

: 1/4" = 1'-0"A6.6A2.1

2 121 PRIVACY ROOM - EAST

: 1/4" = 1'-0"A6.6A2.1

3 121 PRIVACY ROOM - SOUTH

: 1/4" = 1'-0"A6.6A2.1

4 121 PRIVACY ROOM - WEST

3' - 0" 3' - 0" 1' - 6" 1' - 6" 3' - 0" 3' - 0"

3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 4"

A9.5

A9.5

A9.5

A9.5

CASEWORK FILLER

4"

WP-1

3'

1'

3'

WB-1

WP-1

WB-1

PLOTTER HERE

4" 3' - 0" 3' - 0" 3' - 0"

4" 3' - 0" 3' - 0" 3' - 0"

A9.5

A9.5

A9.5

A9.5

CASEWORK FILLER

3'

1'

3'

WB-1

WP-1

WB-1

WP-1

WB-1

3'

12' - 0"

4'

EQ.EQ.

AC- 4

WP-1

WB-1

WP-1

WB-1

VENDING MACHINES

(NIC, OWNER PROVIDED)

WP-1

WP-1

N.I.C.N.I.C.

WB-2

2' - 8" 3' - 0"

A9.5

A9.5

A9.5

2 1/2"

2' - 8" 3' - 0" 2' - 8" 1' - 6" 3' - 0" 1' - 6"5 3/4"

CASEWORK FILLER

CASEWORK FILLER

3'

1'

3'

REFRIG.

N.I.C.

1'

3'

WB-2

FALSE DRAWER PANELS

IN FRONT OF SINK

2'

WP-1

WP-1 ALIGN COUNTER EDGE

W/ EDGE OF WINDOW TRIM

A9.5

LEAVE OFF APRON TRIM AND

ALIGN BACK SPLASH WITH

LOWER EDGE OF STOOL TRIM

A9.13

A9.13

WB-2 S7

WORK SURFACE BRACKET,

RIGID STEEL MOUNTED TO

TRIMBOARD LEDGER TYP.

1' - 0" 4' - 0" 2' - 6 1/2"

WP-1

A9.5

WB-2

2' - 5 1/4" 4' - 0" 1' - 0"

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.7

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.7A2.1

1 137 PRINT ROOM - NORTH

: 1/4" = 1'-0"A6.7A2.1

2 137 PRINT ROOM - EAST

: 1/4" = 1'-0"A6.7A2.1

3 137 PRINT ROOM - SOUTH

: 1/4" = 1'-0"A6.7A2.1

4 137 PRINT ROOM - WEST

: 1/4" = 1'-0"A6.7A2.1

5 138 SMALL CONFERENCE / LACTATION ROOM - NORTH

: 1/4" = 1'-0"A6.7A2.1

6 138 SMALL CONFERENCE / LACTATION ROOM - EAST

: 1/4" = 1'-0"A6.7A2.1

7 138 SMALL CONFERENCE / LACTATION ROOM - SOUTH

: 1/4" = 1'-0"A6.7A2.1

8 138 SMALL CONFREENCE / LACTATION ROOM - WEST

: 1/4" = 1'-0"A6.7A2.1

9 139 BREAK ROOM - NORTH

: 1/4" = 1'-0"A6.7A2.1

10 139 BREAK ROOM - EAST

: 1/4" = 1'-0"A6.7A2.1

11 139 BREAK ROOM - SOUTH

: 1/4" = 1'-0"A6.7A2.1

12 139 BREAK ROOM - WEST

AND CORNERING

REF. TYP./6 A9.7

TA-6

TA-7

TA-8

TA-8

TA-4 TA-11

TA-5

WP-1

4 1/2"1' - 6" 1' - 0" 1' - 6"

A9.5

14 TYP.

TA-8

TA-3

TA-11

WP-1

TA-1

TA-2

TA-12

TA-3

TA-11

WP-1

TA-6

TA-7

TA-12

TA-4

WP-1

TA-1

TA-2

TA-3

TA-11

WP-1

1' - 6" 1' - 0" 1' - 6"7 3/4"

TA-8

TA-3

TA-11

WP-1

TA-6

TA-7

TA-8

TA-8

TA-4

TA-11

WP-1

TA-6

TA-7

TA-4

C L

NOTES:

1) SUBMIT ACCESSORIES FOR REVIEW

2) ALL TOILET ROOM FIXTURES AND ACCESSORIES TO BE ADA COMPLIANT.

3) PROVIDE BLOCKING FOR ACCESSORY MOUNTING

4) DIMENSIONS REFER TO BOTH FLOOR AND WALL MOUNTED TOILETS. ALL DIMENSIONS ARE

FINISH UNLESS OTHERWISE NOTED

40"

54"

42"

18"

M A

X

"8" MIN

2' - 0" TYP

CLR.

48"

TA-7 TA-6

TA-7

TA-6

TA-8

TA-5

TA-11

TA-9

TA-5 TA-10TA-4

33"

4"

FRP

(2 SIDES)

TA-21

/1 6"

24"

24"

M A

X

TA-3

TA-2 TA-121' - 6"

TA-8

TA-6

TOILET ACCESSORIES & TYPICAL MOUNTING HEIGHTS

SEE PLUMBING DRAWINGS

TOILET PARTITION

FIRE EXTINGUISHER

CABINET

TA-1

M A

X

M A

X

TOILET ACCESSORIES

TA-1 = WASTE RECEPTACLE W/ PAPER TOWEL DISPENSER

TA-2 = WARM-AIR ELECTRIC DRYERS

TA-3 = FOAMING-SOAP DISPENSER

TA-4 = TOILET TISSUE DISPENSER

TA-5 = SANITARY NAPKIN DISPOSAL UNIT

TA-6 = HORIZONTAL GRAB BAR, 36" LONG

TA-7 = VERTICAL GRAB BAR, 18" LONG

TA-8 = SEAT-COVER DISPENSER

TA-9 = MIRROR UNIT - SIZE PER ELEVATION

TA-10 = DIAPER-CHANGING STATION

TA-11 = UNDERLAVATORY GUARD

TA-12 = not used

TA-13 = TOILET PARTITION HOOKS, STAINLESS STEEL (TYP. EVERY STALL)

TA-14 = MOP & BROOM HOLDER

TA-4

TA-5

TA-8

WP-1

OPEN

SINKS

WP-1

OPEN

SINKS

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.8

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.8A2.1

1 140 WOMENS RESTROOM - NORTH

: 1/4" = 1'-0"A6.8A2.1

3 140 WOMENS RESTROOM - EAST

: 1/4" = 1'-0"A6.8A2.1

4 140 WOMENS RESTROOM - SOUTH

: 1/4" = 1'-0"A6.8A2.1

5 140 WOMENS RESTROOM - WEST

: 1/4" = 1'-0"A6.8A2.1

6 141 MENS RESTROOM - NORTH

: 1/4" = 1'-0"A6.8A2.1

8 141 MENS RESTROOM - EAST

: 1/4" = 1'-0"A6.8A2.1

9 141 MENS RESTROOM - SOUTH

: 1/4" = 1'-0"A6.8A2.1

10 141 MENS RESTROOM - WEST

: 1/4" = 1'-0"A6.8A2.1

2 140 WOMENS RESTROOM - EAST STALL

: 1/4" = 1'-0"A6.8A2.1

7 141 MENS RESTROOM - EAST STALL

3'

EQ. EQ.12' - 0"

4'

WP-1

AC- 4

WB-1

WP-1

WB-1

WP-1

WP-1

OPEN TO

RECEPTION

AREA

WP-1WP-1 A9.4

A9.4

A9.4

WB-1

WW-2

CVG DOUG FIR WOOD

TRIMED REF. SIM. /5 A9.4

8' - 0"

WP-2

WB-1

ELEVATOR DOOR

WG-1

REF.

/7 A9.8

WP-1

WB-1

WP-1 WP-1

A9.4

A9.4

A9.4

CVG DOUG FIR WOOD

TRIMED REF. SIM. /5 A9.4

WB-1

WP-1 MATCH CORNERING

DETAIL IN KIND TO

LOBBY RECEPTION

DESK REF. /7 A6.1

3' - 2" 4' - 10" 4 3/4"

OPEN TO

CIRCULATION

WP-1

SYSTEMS FURNITURE

WB-1

WP-1

WB-1

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.9

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.9A2.2

2 201 LARGE CONFERENCE ROOM - SOUTH

: 1/4" = 1'-0"A6.9A2.2

1 201 LARGE CONFERENCE ROOM - NORTH

: 1/4" = 1'-0"A6.9A2.2

3 201 LARGE CONFERENCE ROOM - EAST

: 1/4" = 1'-0"A6.9A2.2

4 201 LARGE CONFERENCE ROOM - WEST

: 1/4" = 1'-0"A6.9A2.2

5 210A CORRIDOR - NORTH

: 1/4" = 1'-0"A6.9A2.2

7 210A CORRIDOR - EAST

: 1/4" = 1'-0"A6.9A2.2

8 210A CORRIDOR - WEST

: 1/4" = 1'-0"A6.9A2.2

9 213 EXECUTIVE ASSIST. / WAITING - NORTH

: 1/4" = 1'-0"A6.9A2.2

10 213 EXECUTIVE ASSIST. / WAITING - EAST

: 1/4" = 1'-0"A6.9A2.2

11 213 EXECUTIVE ASSIST. / WAITING - SOUTH

: 1/4" = 1'-0"A6.9A2.2

12 213 EXECUTIVE ASSIST. / WAITING - WEST

WP-1

3' - 0" 3' - 0"

4'

A9.5

4"

WB-1

WP-1

WB-1

WP-1

WB-1

WP-1

WB-1

WP-1

WB-1

WP-1

A9.13

A9.13

1 SIM.

S6

WB-1

3'

" WP-1

4'

12' - 0" EQ.EQ.

AC- 4

WB-1

WP- 1

WB-1

3' - 0"3' - 0"

3' - 0" 3' - 0" 4"

A9.5

A9.5

3'

1'

3'

WB-1

WP- 1

CASEWORK FILLER

PANEL TYP. 12' - 0"

4'

3'

EQ. EQ.

AC- 4

WP- 1

WB-1

WP-1

WB-1

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.10

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.10A2.2

3 215 SUPERVISOR FILING - SOUTH

: 1/4" = 1'-0"A6.10A2.2

4 215 SUPERVISOR FILING - WEST

: 1/4" = 1'-0"A6.10A2.2

2 215 SUPERVISOR FILING - EAST

: 1/4" = 1'-0"A6.10A2.2

1 215 SUPERVISOR FILING - NORTH

: 1/4" = 1'-0"A6.10A2.2

5 224 MEDIUM CONFERENCE ROOM - NORTH

: 1/4" = 1'-0"A6.10A2.2

6 224 MEDIUM CONFERENCE ROOM - SOUTH

: 1/4" = 1'-0"A6.10A2.2

7 224 MEDIUM CONFERENCE ROOM - EAST

: 1/4" = 1'-0"A6.10A2.2

8 224 MEDIUM CONFERENCE ROOM - WEST

: 1/4" = 1'-0"A6.10A2.2

9 225 MEDIUM CONFERENCE ROOM - NORTH

: 1/4" = 1'-0"A6.10A2.2

10 225 MEDIUM CONFERENCE ROOM - SOUTH

: 1/4" = 1'-0"A6.10A2.2

11 225 MEDIUM CONFERENCE ROOM - EAST

: 1/4" = 1'-0"A6.10A2.2

12 225 MEDIUM CONFERENCE ROOM - WEST

WP- 1

3' - 0" 3' - 0" 1' - 6" 1' - 6" 3' - 0" 3' - 0" 4"

3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0"

A9.5

A9.5

A9.5

A9.5

WP- 1

CASEWORK FILLER

3'

1'

3'

CASEWORK FILLER

WB-1

WP- 1

WB-1

4" 3' - 0" 3' - 0" 3' - 0"

3' - 0" 3' - 0" 3' - 0"

A9.5

A9.5

A9.5

A9.5

WP- 1

CASEWORK FILLER

4"

3'

1'

3'

WB-1

WP- 1

4'

12' - 0"EQ. EQ.

WB-1

VENDING MACHINES

(NIC,OWNER PROVIDED

WB-2

WP-1

2' - 8" 3' - 0" 2' - 8"

A9.5

A9.5

A9.5

REFRIG.

N.I.C.

2 1/2" 2' - 8" 3' - 0" 2' - 8" 1' - 6" 3' - 0" 1' - 6" 6"

CASEWORK FILLER

CASEWORK FILLER

3'

1'

3'

CASEWORK FILLER

WB-2

A9.5

9 SIM.

WP-1

FALSE DRAWER PANELS

IN FRONT OF SINK

WP- 1

A9.5

ALIGN COUNTER EDGE

W/ EDGE OF WINDOW TRIM

LEAVE OFF APRON TRIM AND

ALIGN BACK SPLASH WITH

LOWER EDGE OF STOOL TRIM

2'

WB-2

1' - 0" 5' - 0" 5' - 0" 2' - 2 3/4"

WORK SURFACE BRACKET,

RIGID STEEL MOUNTED TO

TRIMBOARD LEDGER TYP.

WP- 1

2'

WB-2

2' - 5 3/4" 4' - 0" 1' - 0"

WP- 1

WB-1

WP- 1

WB-1

WP- 1

WB-1

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.11

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.11A2.2

1 232 PRINT ROOM - NORTH

: 1/4" = 1'-0"A6.11A2.2

2 232 PRINT ROOM - EAST

: 1/4" = 1'-0"A6.11A2.2

3 232 PRINT ROOM - SOUTH

: 1/4" = 1'-0"A6.11A2.2

4 232 PRINT ROOM - WEST

: 1/4" = 1'-0"A6.11A2.2

7 233 SMALL CONFERENCE ROOM - SOUTH

: 1/4" = 1'-0"A6.11A2.2

9 234 BREAK ROOM - NORTH

: 1/4" = 1'-0"A6.11A2.2

10 234 BREAK ROOM - EAST

: 1/4" = 1'-0"A6.11A2.2

11 234 BREAK ROOM - SOUTH

: 1/4" = 1'-0"A6.11A2.2

12 234 BREAK ROOM - WEST

: 1/4" = 1'-0"A6.11A2.2

6 233 SMALL CONFERENCE ROOM - EAST

: 1/4" = 1'-0"A6.11A2.2

5 233 SMALL CONFERENCE ROOM - NORTH

: 1/4" = 1'-0"A6.11A2.2

8 233 SMALL CONFERENCE ROOM - WEST

WP- 1 WP- 1

AND CORNERING

REF. TYP./6 A9.7

TA-6

TA-7

TA-8

TA-11

TA-8

TA-4

TA-5

WP- 1

8" 1' - 6" 1' - 0" 1' - 6"

A9.5

14 TYP.

TA-8

TA-3

TA-11

WP- 1

TA-1

TA-2

TA-12

TA-3

TA-11

WP- 1

TA-6

TA-7

TA-12

TA-4

WP- 1

TA-1

TA-2

TA-3

TA-11

WP- 1

1' - 6" 1' - 0" 1' - 6"7 3/4"

TA-8

TA-3

TA-11

WP- 1WP- 1

TA-6

TA-7

TA-8

TA-8

TA-4

TA-11

WP- 1

TA-6

TA-7

TA-4

C L

NOTES:

1) SUBMIT ACCESSORIES FOR REVIEW

2) ALL TOILET ROOM FIXTURES AND ACCESSORIES TO BE ADA COMPLIANT.

3) PROVIDE BLOCKING FOR ACCESSORY MOUNTING

4) DIMENSIONS REFER TO BOTH FLOOR AND WALL MOUNTED TOILETS. ALL DIMENSIONS ARE

FINISH UNLESS OTHERWISE NOTED

40"

54"

42"

18"

M A

X

"8" MIN

2' - 0" TYP

CLR.

48"

TA-7 TA-6

TA-7

TA-6

TA-8

TA-5

TA-11

TA-9

TA-5 TA-10TA-4

33"

4"

FRP

(2 SIDES)

TA-21

/1 6"

24"

24"

M A

X

TA-3

TA-2 TA-121' - 6"

TA-8

TA-6

TOILET ACCESSORIES & TYPICAL MOUNTING HEIGHTS

SEE PLUMBING DRAWINGS

TOILET PARTITION

FIRE EXTINGUISHER

CABINET

TA-1

M A

X

M A

X

TOILET ACCESSORIES

TA-1 = WASTE RECEPTACLE W/ PAPER TOWEL DISPENSER

TA-2 = WARM-AIR ELECTRIC DRYERS

TA-3 = FOAMING-SOAP DISPENSER

TA-4 = TOILET TISSUE DISPENSER

TA-5 = SANITARY NAPKIN DISPOSAL UNIT

TA-6 = HORIZONTAL GRAB BAR, 36" LONG

TA-7 = VERTICAL GRAB BAR, 18" LONG

TA-8 = SEAT-COVER DISPENSER

TA-9 = MIRROR UNIT - SIZE PER ELEVATION

TA-10 = DIAPER-CHANGING STATION

TA-11 = UNDERLAVATORY GUARD

TA-12 = not used

TA-13 = TOILET PARTITION HOOKS, STAINLESS STEEL (TYP. EVERY STALL)

TA-14 = MOP & BROOM HOLDER

TA-4

TA-5

TA-8

WP- 1

OPEN

SINKS

WP- 1

OPEN

SINKS

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A6.12

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

INTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

AN

BP

: 1/4" = 1'-0"A6.12A2.2

1 235 WOMENS RESTROOM - NORTH

: 1/4" = 1'-0"A6.12A2.2

3 235 WOMENS RESTROOM - EAST

: 1/4" = 1'-0"A6.12A2.2

4 235 WOMENS RESTROOM - SOUTH

: 1/4" = 1'-0"A6.12A2.2

5 235 WOMENS RESTROOM - WEST

: 1/4" = 1'-0"A6.12A2.2

6 236 MENS RESTROOM - NORTH

: 1/4" = 1'-0"A6.12A2.2

8 236 MENS RESTROOM - EAST

: 1/4" = 1'-0"A6.12A2.2

9 236 MENS RESTROOM - SOUTH

: 1/4" = 1'-0"A6.12A2.2

10 236 MENS RESTROOM - WEST

: 1/4" = 1'-0"A6.12A2.2

2 235 WOMENS RESTROOM - EAST STALL

: 1/4" = 1'-0"A6.12A2.2

7 236 MENS RESTROOM - EAST STALL

PF

A B

C

R E

F

PF

A

C

E

D

B

STORAGE

BUILDING

STORAGE

FOYER

GYP. BD.

8' - 0"

MECHANICAL

ROOM

TEL/COMM

GYP. BD.

8' - 0"

GYP. BD.

8' - 0"

GYP

. B

D.

7'

- 6

JAN.

STG.

GYP. BD.

8' - 0"

EMR

003A

GYB. BD.

8' - 0"

GYB. BD.

8' - 0"

OPEN TO STAIR

ABOVE

CHASE

ELEV.

1. IF NO HATCH IS SHOWN , CEILING CONDITION IS NOTED IN THE DRAWINGS.

2. REFER TO ELECTRICAL SHEETS FOR FIXTURE TYPES, SWITCHING, SPECIAL SYSTEMS AND

LAYOUTS.

3. REFER TO ELECTRICAL SHEETS FOR DEMOLISHED &/OR REINSTALLED FIXTURE LOCATIONS.

4. REFER TO MECHANICAL SHEETS FOR DIFFUSER AND DUCTING LAYOUTS.

5. MECHANICAL RETURN AIR PLENUM INDICATED ON PLAN ON THIS SHEET.

6. REFERENCE EXTERIOR FINISH LEGEND FOR EXTERIOR PAINT COLORS; REFERENCE FINISH

SCHEDULE FOR INTERIOR PAINT COLORS AND FINISH.

7. ALL CEILING ASSEMBLIES SHALL HAS A IMPACT ISOLATION CLASS RATING OF AT LEAST 50.

RCP - GENERAL NOTESREFLECTED CEILING PLAN LEGEND

ACT-1, (ACOUSTICAL CEILING TILE) W/ 2' X 2'

METAL SUSPENSION SYSTEM, TEGULAR, ICC-50

5/8" GYP. BD. CEILING W/ METAL

SUSPENSION SYSTEM, PAINT. ICC-50.

T&G WOOD SOFFIT, VENTED. ONLY AT SECOND

LEVEL EXTERIOR PERIMETER SOFFIT, SEE

KEYNOTE #4. CONTINUOUS VENT SCREEN AT

EDGE OF SOFFIT, TYP. SEE

TUBULAR SKYLIGHT (USED

ONLY ON THE SECOND FLOOR)

ACT-2, (ACOUSTICAL CEILING TILE), 4' X 4' METAL

SUSPENSION SYSTEM, 1'-0" ZONE WITH LIGHTING

AND SLOT DIFFUSERS. ICC-50. DIAGONAL INDICATES

AREA FOR LIGHTING AND HVAC DIFFUSERS. BASIS

OF DESIGN: ARMSTRONG TECHZONE

SHORT-THROW PROJECTOR AND MOUNT. ASSUMED

ASPECT RATIO OF 4:3. CONTRACTOR TO VERIFY WITH

MANUFACTURER NECESSARY MOUNTING ANGLES

AND DIMENSIONS. BASIS OF DESIGN: PANASONIC PT-

RZ575, WIRELESS/WIRED REMOTE CONTROL UNIT,

PAINTED METAL PROJECTOR CEILING MOUNT.

COORDINATE WITH ELECTRICAL. PROJECTOR MOUNT

TO BE SUPPORTED BACK TO SOLID STRUCTURE PER

MANUFACTURER RECOMMENDATIONS. 4:3 ASPECT

RATIO IS ASSUMED.

NOTE: USED ON ALL PLANS

CASEWORK, UPPER (SHOWN FOR CLARITY)

P

TS

MTL-1, PTD. METAL SOFFIT, VENTED

ACT CEILING TRANSITIONT

/14 A5.2

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A7.0

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

RCP - LOWER LEVEL

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

BP

BP

: 1/8" = 1'-0"A7.0A7.0

11 REFLECTED CEILING PLAN - LOWER LEVEL

B

C

A

C

E

D

B

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-2

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

GYP. BD.

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

OPEN TO STAIR

MEDIUM

CONFERENCE

ROOM

ENTRY

VEST.

LARGE

MEETING

ROOM

STORAGE

105A

VESTIBULE/

BREAKOUT

FHP

OFFICE

144 FHP/BLM

STORAGE

FHP

OPEN

OFFICE

MENS

PUBLIC

RESTROOM

WOMENS

PUBLIC

RESTROOM

ELEC.

CLOS.

PRINT

ROOM

BLM

OPEN

OFFICE

BLM

OFFICE

BLM

OFFICE

BLM

OPEN

OFFICE

LOBBY

MAIL

ROOM

103A

RECEPTION

MEDIUM

CONFERENCE

ROOM

FMO

OPEN

OFFICE

BLM

OFFICE

BLM

OFFICE

BLM

OFFICE

BLM

OFFICE

FMO

OFFICE

CIO

OFFICE

PRIVACY

ROOM

BLM

STG.

LAW

OFFICE

(USFS)

LAW

OFFICE

(USFS)

LAW

OFFICE

(USFS)

LAW

EVIDENCE

ROOM

LAW

OFFICE

(BLM)

LAW

ENFORCEMENT

OPEN

OFFICE

CORRIDOR

113B

GYP. BD.

10' - 0"

GYP. BD.

10' - 0"

ACT-1

10' - 0"

MENS

RESTROOM

WOMENS

RESTROOM

BREAKROOM

SMALL

CONFERENCE

ROOM /

LACTATION

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-1

10' - 0"

ACT-2

10' - 0"

5'

4' - 0"

GYB. BD.

9' - 0"

GYP. BD.

11' - 6"

ACT-2

10' - 0"

ACT-2

10' - 0"

ACT-1

10' - 0"

STAIR 2

M

TL-19' - 6"

M

TL-19' - 6"

M

TL-1

11' - 11 1/2"

GYP. BD.

10' - 0"

GYP. BD.

10' - 0"

GYB. BD.

9' - 0"

ACT-1

10' - 0"

GYP. BD.

11' - 0"

MECH.

ROOM

11' - 0"

ACT-1

10' - 0"

GYB. BD.

8' - 0"

A9.6

GYP. BD.

10' - 0"

GYP. BD.

10' - 0"

P

P

7'

V

IF

7'

V

IF

T

T

T T

A9.6

A9.6

A9.6

A9.6

GYP. BD.

10' - 0"

A6.3

7' - 8"

A9.6

A9.6

A9.6

REFLECTED CEILING PLAN LEGEND

ACT-1, (ACOUSTICAL CEILING TILE) W/ 2' X 2'

METAL SUSPENSION SYSTEM, TEGULAR, ICC-50

5/8" GYP. BD. CEILING W/ METAL

SUSPENSION SYSTEM, PAINT. ICC-50.

T&G WOOD SOFFIT, VENTED. ONLY AT SECOND

LEVEL EXTERIOR PERIMETER SOFFIT, SEE

KEYNOTE #4. CONTINUOUS VENT SCREEN AT

EDGE OF SOFFIT, TYP. SEE

TUBULAR SKYLIGHT (USED

ONLY ON THE SECOND FLOOR)

ACT-2, (ACOUSTICAL CEILING TILE), 4' X 4' METAL

SUSPENSION SYSTEM, 1'-0" ZONE WITH LIGHTING

AND SLOT DIFFUSERS. ICC-50. DIAGONAL INDICATES

AREA FOR LIGHTING AND HVAC DIFFUSERS. BASIS

OF DESIGN: ARMSTRONG TECHZONE

SHORT-THROW PROJECTOR AND MOUNT. ASSUMED

ASPECT RATIO OF 4:3. CONTRACTOR TO VERIFY WITH

MANUFACTURER NECESSARY MOUNTING ANGLES

AND DIMENSIONS. BASIS OF DESIGN: PANASONIC PT-

RZ575, WIRELESS/WIRED REMOTE CONTROL UNIT,

PAINTED METAL PROJECTOR CEILING MOUNT.

COORDINATE WITH ELECTRICAL. PROJECTOR MOUNT

TO BE SUPPORTED BACK TO SOLID STRUCTURE PER

MANUFACTURER RECOMMENDATIONS. 4:3 ASPECT

RATIO IS ASSUMED.

NOTE: USED ON ALL PLANS

CASEWORK, UPPER (SHOWN FOR CLARITY)

P

TS

MTL-1, PTD. METAL SOFFIT, VENTED

ACT CEILING TRANSITIONT

/14 A5.2

KEYNOTES - FIRST/GROUND LEVEL RCP

1. TIMBER-FRAMED STRUCTURE SEE STRUCTURAL AND

DETAILS

2. GWB UNDERSIDE OF STAIRWELL CONSTRUCTION

3. CUSTOM WOOD SCREEN WALL, SEE FLOOR PLANS AND

DETAILS

4. LED STRIP LIGHT LOCATION, SEE ELECTRICAL

5. BEAMS TO TERMINATE AT VESTIBULE, TYP.

6. COORDINATE TRACK SYSTEM WITH WALL PARTITION WITH

SUSPENDED CEILING SYSTEM

KEYNOTE IS DESIGNATED WITH THIS SYMBOL#1. IF NO HATCH IS SHOWN , CEILING CONDITION IS NOTED IN THE DRAWINGS.

2. REFER TO ELECTRICAL SHEETS FOR FIXTURE TYPES, SWITCHING, SPECIAL SYSTEMS AND

LAYOUTS.

3. REFER TO ELECTRICAL SHEETS FOR DEMOLISHED &/OR REINSTALLED FIXTURE LOCATIONS.

4. REFER TO MECHANICAL SHEETS FOR DIFFUSER AND DUCTING LAYOUTS.

5. MECHANICAL RETURN AIR PLENUM INDICATED ON PLAN ON THIS SHEET.

6. REFERENCE EXTERIOR FINISH LEGEND FOR EXTERIOR PAINT COLORS; REFERENCE FINISH

SCHEDULE FOR INTERIOR PAINT COLORS AND FINISH.

7. ALL CEILING ASSEMBLIES SHALL HAS A IMPACT ISOLATION CLASS RATING OF AT LEAST 50.

RCP - GENERAL NOTES

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A7.1

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

RCP - FIRST/GROUND LEVEL

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

BP

BP

: 1/8" = 1'-0"A7.1A7.1

11 REFLECTED CEILING PLAN - FIRST/GROUND LEVEL

B

C

A

C

E

D

B

FWS

OPEN

OFFICE

LARGE

CONFERENCE

ROOM

NEPA

PLANNER

OPEN

OFFICE

ECO

OPEN

OFFICE

VEG

OPEN

OFFICE

PRINT

ROOM

AQM

OPEN

OFFICE

TEC

OPEN

OFFICE

HRM

OPEN

OFFICE

MEDIUM

CONFERENCE

ROOM

FWS

OFFICE

FWS

OFFICE

FWS

OFFICE

FWS

OFFICE

PUBLIC

AFFAIRS

OFFICER

HRM

OFFICE

NIZ

OFFICE

MEDIUM

CONFERENCE

ROOM

TEC

OFFICE

VEG

OFFICE

ECO

OFFICE

SECURITY

OFFICE

SUPERVISOR

FILING

SUPERVISORS

OFFICE

EXECUTIVE

ASSISTANT/

WAITING

DEPUTY

SUP.

OFFICE

FWS

ASST.

STATE

SUPERINTENDENT

OFFICE

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

9' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

GYB. BD.

9' - 0"

ACT-19' - 0"

OPEN TO

LIGHTWELL

ABOVE

CORRIDOR

210A

SMALL

CONFERENCE

ROOM

BREAK

ROOM

MENS

RESTROOM

WOMENS

RESTROOM

GYP. BD.

9' - 0"

ACT-19' - 0"

ACT-19' - 0"

GYP. BD.

9' - 0"

ACT-19' - 0"

GYP. BD.

9' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

TYP.

NIZ

OPEN

OFFICE

TS

TS

TS

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

ACT-19' - 0"

A9.7

A9.6

A9.6

A9.6

3 SIM. SIM.

REFLECTED CEILING PLAN LEGEND

ACT-1, (ACOUSTICAL CEILING TILE) W/ 2' X 2'

METAL SUSPENSION SYSTEM, TEGULAR, ICC-50

5/8" GYP. BD. CEILING W/ METAL

SUSPENSION SYSTEM, PAINT. ICC-50.

T&G WOOD SOFFIT, VENTED. ONLY AT SECOND

LEVEL EXTERIOR PERIMETER SOFFIT, SEE

KEYNOTE #4. CONTINUOUS VENT SCREEN AT

EDGE OF SOFFIT, TYP. SEE

TUBULAR SKYLIGHT (USED

ONLY ON THE SECOND FLOOR)

ACT-2, (ACOUSTICAL CEILING TILE), 4' X 4' METAL

SUSPENSION SYSTEM, 1'-0" ZONE WITH LIGHTING

AND SLOT DIFFUSERS. ICC-50. DIAGONAL INDICATES

AREA FOR LIGHTING AND HVAC DIFFUSERS. BASIS

OF DESIGN: ARMSTRONG TECHZONE

SHORT-THROW PROJECTOR AND MOUNT. ASSUMED

ASPECT RATIO OF 4:3. CONTRACTOR TO VERIFY WITH

MANUFACTURER NECESSARY MOUNTING ANGLES

AND DIMENSIONS. BASIS OF DESIGN: PANASONIC PT-

RZ575, WIRELESS/WIRED REMOTE CONTROL UNIT,

PAINTED METAL PROJECTOR CEILING MOUNT.

COORDINATE WITH ELECTRICAL. PROJECTOR MOUNT

TO BE SUPPORTED BACK TO SOLID STRUCTURE PER

MANUFACTURER RECOMMENDATIONS. 4:3 ASPECT

RATIO IS ASSUMED.

NOTE: USED ON ALL PLANS

CASEWORK, UPPER (SHOWN FOR CLARITY)

P

TS

MTL-1, PTD. METAL SOFFIT, VENTED

ACT CEILING TRANSITIONT

/14 A5.2

1. IF NO HATCH IS SHOWN , CEILING CONDITION IS NOTED IN THE DRAWINGS.

2. REFER TO ELECTRICAL SHEETS FOR FIXTURE TYPES, SWITCHING, SPECIAL SYSTEMS AND

LAYOUTS.

3. REFER TO ELECTRICAL SHEETS FOR DEMOLISHED &/OR REINSTALLED FIXTURE LOCATIONS.

4. REFER TO MECHANICAL SHEETS FOR DIFFUSER AND DUCTING LAYOUTS.

5. MECHANICAL RETURN AIR PLENUM INDICATED ON PLAN ON THIS SHEET.

6. REFERENCE EXTERIOR FINISH LEGEND FOR EXTERIOR PAINT COLORS; REFERENCE FINISH

SCHEDULE FOR INTERIOR PAINT COLORS AND FINISH.

7. ALL CEILING ASSEMBLIES SHALL HAS A IMPACT ISOLATION CLASS RATING OF AT LEAST 50.

RCP - GENERAL NOTES KEYNOTES - SECOND LEVEL RCP

1. ARCHITECTURAL ROOF BRACKETS AND OUTLOOKERS, DOUG FIR, CLEAR OIL FINISH, SEE

STRUCTURAL.

2. WOOD CEILING TO CONTINUE UP LIGHTWELL TO SKYLIGHT, SEE INTERIOR ELEVATIONS

AND DETAILS.

3. CUSTOM WOOD SCREEN WALL, SEE FLOOR PLANS AND DETAILS

4. T&G DOUG FIR WOOD SOFFIT, OIL CLEAR FINISH, TYP.

KEYNOTE IS DESIGNATED WITH THIS SYMBOL#

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A7.2

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

RCP - SECOND LEVEL

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

BP

BP

: 1/8" = 1'-0"A7.2A7.2

11 REFLECTED CEILING PLAN - SECOND LEVEL

File details come from the government source that posted it. Updated .