Drawings_Part_12_2018_06-01.pdf
PDF 4 MB Posted
- Attached to
- INRC - Phase III
- Solicitation number
- 12034318R0017
About this file
This is a pre-solicitation notice for construction of Phase III of the Interagency Natural Resource Center in Coeur d'Alene, Idaho. The project includes a 29,000 square foot main office building to support 173 employees from the U.S. Fish & Wildlife Service, Bureau of Land Management, and U.S. Forest Service. The project magnitude is estimated between $5 million and $10 million. The solicitation for proposals is expected to be posted on or around June 5, 2018 with responses due 30 days after posting. The project will be awarded by the Northern Region of the U.S. Forest Service.
22 - J-3 Drawings Part 12
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HP-2
REYQ360TTJU
REYQ120TTJU REYQ120TTJU REYQ120TTJU
½"×1⅛"×¾" ½"×1⅛"×¾" ⅝"x1⅜"x1⅛"
½"×1⅛"×¾"
BHFP26P151U
160.0ft [8]
KHRP25M73TU9
⅞"×1⅝"×1⅜" * 5.0ft
KHRP25M73TU9
⅝"×1⅛"×1⅛"
BS-25
BSQ36TVJ
5.0ft ⅜"×⅝"×½"
FC-234
FXMQ36PBVJU
10.0ft [2] ⅜"×⅝"
15.0ft
KHRP25M73TU9
⅝"×1⅛"×1⅛" 15.0ft
KHRP25A33T9
⅜"×⅞"×¾"
BS-26
BSQ60TVJ
3.0ft ⅜"×⅝"×½"
FC-237
FXMQ48PBVJU
5.0ft [2] ⅜"×⅝"
BS-14
BSQ36TVJ
10.0ft ⅜"×⅝"×½"
FC-202
FXMQ24PBVJU
15.0ft [2] ⅜"×⅝"
20.0ft
KHRP25A33T9
⅜"×⅞"×¾"
BS-17
BSQ36TVJ
5.0ft ⅜"×⅝"×½"
FC-214
FXMQ30PBVJU
5.0ft [2] ⅜"×⅝"
25.0ft
KHRP25A22T9
⅜"×¾"×⅝"
BS-16
BSQ36TVJ
5.0ft ⅜"×⅝"×½"
FC-205
FXMQ30PBVJU
5.0ft [2] ⅜"×⅝"
10.0ft
KHRP25A22T9
⅜"×⅝"×½"
BS-15
BSQ36TVJ
5.0ft ⅜"×⅝"×½"
FC-204
FXMQ15PBVJU
5.0ft [2] ¼"×½" *
BS-13
BSQ36TVJ
10.0ft ⅜"×⅝"×½"
FC-201
FXFQ24TVJU
10.0ft [2] ⅜"×⅝"
25.0ft [2]
KHRP25M73TU9
⅝"×1⅛"×1⅛"
BS-20
BSQ36TVJ
15.0ft ⅜"×⅝"×½"
FC-225
FXFQ18TVJU
10.0ft [2] ¼"×½" *
10.0ft
KHRP25M73TU9
⅝"×1⅛"×1⅛"
BS-24
BSQ60TVJ
15.0ft ⅜"×⅝"×½"
3.0ft
KHRP26A22T9
⅜"×⅝"
FC-231
FXMQ30PBVJU
15.0ft [2] ⅜"×⅝"
FC-232
FXZQ15MVJU9
15.0ft [2] ¼"×½"
10.0ft
KHRP25M72TU9
½"×1⅛"×¾"
BS-21
BSQ36TVJ
15.0ft ⅜"×⅝"×½"
FC-226
FXMQ18PBVJU
5.0ft [2] ¼"×½" *
15.0ft
KHRP25M72TU9
½"×1⅛"×¾"
BS-19
BSQ36TVJ
3.0ft ⅜"×⅝"×½"
FC-224
FXZQ12MVJU9
5.0ft [2] ¼"×½" *
5.0ft
KHRP25M72TU9
½"×1⅛"×¾"
BS-18
BSQ36TVJ
3.0ft ⅜"×⅝"×½"
FC-216
FXMQ15PBVJU
5.0ft [2] ¼"×½" *
5.0ft
KHRP25A33T9
⅜"×⅞"×¾"
BS-22
BSQ60TVJ
15.0ft ⅜"×⅝"×½"
FC-228
FXMQ48PBVJU
10.0ft [2] ⅜"×⅝"
BS-23
BSQ60TVJ
20.0ft [2] ⅜"×¾"×⅝" *
FC-230
FXMQ54PBVJU
5.0ft [2] ⅜"×⅝"
HP-1
REYQ384TTJU
REYQ168TTJU REYQ120TTJU REYQ96TTJU
⅝"×1⅛"×⅞" ½"×1⅛"×¾" ⅝"x1⅜"x1⅛"
⅜"×⅞"×¾"
BHFP26P151U
80.0ft [6]
KHRP25M73TU9
¾"×1⅝"×1⅜" 35.0ft [2]
KHRP25M73TU9
⅝"×1⅛"×1⅛" 15.0ft
KHRP25M72TU9
½"×1⅛"×¾" 5.0ft
KHRP25A33T9
⅜"×⅞"×¾" 10.0ft
KHRP25A33T9
⅜"×⅞"×¾"
BS-2
BSQ36TVJ
5.0ft [1] ⅜"×⅝"×½"
FC-123
FXMQ24PBVJU
25.0ft [2] ⅜"×⅝"
BS-1
BSQ60TVJ
15.0ft ⅜"×⅝"×½"
FC-131
FXMQ48PBVJU
25.0ft [4] ⅜"×⅝"
BS-11
BSQ36TVJ
15.0ft ⅜"×⅝"×½"
FC-136
FXMQ30PBVJU
5.0ft [2] ⅜"×⅝"
BS-3
BSQ60TVJ
15.0ft [2] ⅜"×⅝"×½"
5.0ft
KHRP26A22T9
⅜"×⅝"
FC-122a
FXMQ30PBVJU
25.0ft [4] ⅜"×⅝"
FC-122b
FXMQ15PBVJU
20.0ft [3] ¼"×½"
BS-4
BSQ36TVJ
10.0ft ⅜"×⅝"×½"
3.0ft
KHRP26A22T9
⅜"×⅝"
FC-127
FXMQ07PBVJU
25.0ft [3] ¼"×½"
FC-117
FXMQ18PBVJU
25.0ft [3] ¼"×½"
5.0ft
KHRP25M73TU9
¾"×1⅜"×1⅛"
BS-5
BSQ36TVJ
5.0ft ⅜"×⅝"×½"
FC-114
FXZQ15MVJU9
10.0ft [2] ¼"×½" *
3.0ft
KHRP25M73TU9
¾"×1⅜"×1⅛"
BS-6
BSQ60TVJ
3.0ft ⅜"×⅝"×½"
10.0ft
KHRP26A22T9
⅜"×⅝"
FC-137
FXZQ18MVJU9
10.0ft [3] ¼"×½"
FC-139
FXMQ30PBVJU
15.0ft [2] ⅜"×⅝"
20.0ft
KHRP25M73TU9
¾"×1⅜"×1⅛"
BS-7
BSQ60TVJ
30.0ft ⅜"×¾"×⅝" *
FC-143
FXMQ54PBVJU
5.0ft [2] ⅜"×⅝"
30.0ft
KHRP25M73TU9
⅝"×1⅛"×1⅛"
BS-9
BSQ36TVJ
5.0ft ⅜"×⅝"×½"
FC-103
FXMQ24PBVJU
15.0ft [3] ⅜"×⅝"
15.0ft
KHRP25M72TU9
½"×1⅛"×¾"
BS-10
BSQ36TVJ
5.0ft ⅜"×⅝"×½"
FC-104
FXMQ12PBVJU
5.0ft [2] ¼"×½" *
10.0ft
KHRP25M72TU9
½"×1⅛"×¾"
BS-12
BSQ96TVJ
5.0ft ⅜"×⅞"×¾"
FC-105b
FXMQ72MVJU
20.0ft [2] ⅜"×¾" *
BS-8
BSQ96TVJ
5.0ft ⅜"×⅞"×¾"
FC-105a
FXMQ72MVJU
15.0ft [2] ⅜"×¾" *
VARIABLE REFRIGERANT (VRF) SYSTEM SCHEMATIC: SYSTEM #1 & #2
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:0 :2
P
M
M9.2
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
REFRIGERANT PIPING SCHEMATICS
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
BJK/JTW
TJB
JTW
P
R E E
NI
GN
ELANOISSEF
O R R
EG
ISTERE
D
S
T A
TE OF ID
AH
O
WAVERE
K
TYD
O J
11076
PIPE SCHEDULE
SYSTEM PIPE MATERIAL SIZE
INSULATION
THICKNESS REMARKS
DOM. COLD WATER - ABOVE GRADE TYPE L COPPER ALL 1/2" PRO-PRESS OR SWEAT
DOM. COLD WATER - MAIN SUPPLY
TYPE L COPPER OR
AQUATHERM (GREEN) ALL 1/2"
PRO-PRESS OR SWEAT, OR
HEAT FUSION (AQUATHERM)
DOM. HOT WATER - ABOVE GRADE TYPE L COPPER ALL 1" PRO-PRESS OR SWEAT
DOM. HOT WATER - MAIN SUPPLY
TYPE L COPPER OR
AQUATHERM (GREEN) ALL 1"
PRO-PRESS OR SWEAT, OR
HEAT FUSION (AQUATHERM)
WASTE PVC ALL NONE NEW SANITARY WASTE
VENT PVC ALL NONE NEW VENT PIPING
NATURAL GAS PIPING STEEL ALL NONE - -
NOTE:
1. INSULATION THICKNESS IS BASED ON A CONDUCTIVITY NOT EXCEEDING .27 BTU PER INCH/H * FT^2 * °F
2. PLASTIC PIPE SHALL NOT BE INSTALL WITHIN THE FIRST 18" OF A WATER HEATER.
OUTSIDE DIAMETER OF PIPE
OR COVERING LENGTH OF COLOR FIELD A SIZE OF LETTERS B
INCHES MM INCHES MM INCHES MM
3/4" TO 1-1/4" 19 TO 32 8" 200 1/2" 13
1-1/2" TO 2" 38 TI 51 8" 200 3/4" 19
2-1/2" TO 6" 64 TO 150 12" 300 1-1/4" 32
8" TO 10" 200 TO 250 24" 600 2-1/2" 64
OVER 10" OVER 250 32" 800 3-1/2" 89
SERVICE BACKGROUND LETTER COLOR
DOMESTIC COLD WATER GREEN WHITE
DOMESTIC HOT WATER YELLOW BLACK
DOMESTIC HOT WATER RETURN YELLOW BLACK
FIRE PROTECTION (SPRINKLER) RED WHITE
FUEL GAS YELLOW BLACK
SANITARY DRAIN GREEN WHITE
PLUMBING FIXTURE SCHEDULE
MARK DESCRIPTION MANUF MODEL NUMBER
MOUNTING /
MOUNTING
HEIGHT
MATERIAL & FINISH TRIM
SIZE AT FINAL CONNECTION TO FIXTURE
REMARKS
DRAIN VENT COLD HOT
BP1 BACKFLOW PREVENTER - REDUCED PRESS ZONE-LEAD FREE WATTS LF009-QT-S PIPE BRONZE BODY - LEAD FREE
SHUT-OFF VALVES, STRAINER, AIR
GAP LINE SIZE - - LINE SIZE - - REDUCED PRESSURE ZONE BACKFLOW PREVENTER WITH SHUT-OFF VALVES, STRAINER, AND AIR GAP FITTING - DRAIN TO NEAREST FLOOR DRAIN
BV BALL VALVE - TWO PIECE - FULL PORT - LEAD FREE WATTS LFB6081G2 PIPE BRONZE CONSTRUCTION - LEAD FREE SOLDER ENDS - - - - LINE SIZE LINE SIZE BRONZE BALL VALVE - TWO PIECE - FULL PORT - 600 PSIG WOG - BLOW-OUT PROOF STEM
CV CHECK VALVE - WYE PATTERN WATTS LFWCVS PIPE BRASS CONSTRUCTION - LEAD FREE BRONZE DISK - - - - LINE SIZE LINE SIZE WYE PATTERN BRONZE CHECK VALVE - 200 PSIG WOG
ET1 EXPANSION TANK - SMALL ASME RATED AMTROL ST-12 PIPE STEEL - BUTYL DIAPHRAGM - ANTIMICROBIAL WITH CHARGING VALVE - - - - - - 3 / 4" THERMAL EXPANSION ABSORBER - ANTI MICROBIAL LINER - 4.4 GALLON TOTAL VOLUME - 3.2 GALLON ACCEPTANCE VOLUME
EWC1 ELECTRIC WATER COOLER - DUAL HEIGHT - BOTTLE FILLER HALSEY TAYLOR HTHB-HACG8BLSS-NF
WALL / UPPER
ORIFICE 39.5" -
LOWER 33"
STAINLESS STEEL - LEAD FREE WITH BOTTLE FILLER 2" 1 - 1 / 2" 1 / 2" - - 1.1 GPM BOTTLE FILL RATE - BI-LEVEL UNIT - 8.0 GALLONS PER HOUR - 120 VOLT - EASY FLEX BUBBLER - PROVIDE P-TRAP AND WATER SERVICE STOP -
BRASSCRAFT #KTCR STOP
FCO FLOOR CLEAN OUT JR SMITH 4021S FLOOR
CAST IRON BODY / BRONZE PLUG / NICKEL
BRONZE TOP
TWIST ADJUSTMENT - CARPET
CLAMP WHERE REQUIRED 2" - 4" SEE PLANS - - - - - - PROVIDE WITH CARPET CLAMP AT CARPET AREAS
FD1 FLOOR DRAIN WITH ADJUSTABLE HEIGHT ROUND STRAINER JR SMITH 2005 FLOOR CAST IRON BODY / NICKEL BRONZE STRAINER TRAP PRIMER CONNECTION 2" - 4" SEE PLANS 1-1/2"-2"SEE PLANS - - - - PROVIDE COMPLETE WITH PRO SEAL "TRAP GUARD" TRAP SEAL PRIMER
IM1 PLASTIC ICE MAKER BOX LSP OB-801 WALL / VARIES BRASS CONSTRUCTION - WETTED AREAS WITH MIP VALVE - - - - 1 / 2" 1 / 2" PLASTIC BOX WITH MIP BALL VALVE - MOUNT ABOVE COUNTER BACKSPLASH
L1 LAVATORY - COUNTERTOP - TOUCHLESS FAUCET KOHLER K-2210 UNDER-COUNTER VITREOUS CHINA W/ MOEN #8554 FAUCET-GRID DRAIN 2" 1 - 1 / 2" 1 / 2" 1 / 2" WITH ELECTRONIC FAUCET & BRASSCRAFT #KTCR QUARTER TURN STOPS
LHCO LAMP HOLE CLEAN OUT JR SMITH 4261L GRADE CAST IRON BODY / HEAVY DUTY COVER SPEEDI - SET NO-HUB FITTING 4" - - - - - - FINISH AT GRADE
MV1 MIXING VALVE - SINGLE SYMMONS 7-500 - B SERIES WALL / 48" BRONZE AND STAINLESS STEEL - LEAD FREE WITH 3" DIA THERMOMETER - - - - 1" 1' 1 - 1 / 4" OUTLET - 0.5 GPM MINIMUM - 50 GPM MAXIMUM (20 PSI DROP) - PROVIDE CABINET, CHECK STOPS, REMOVABLE CARTRIDGE, VACUUM BREAKER, &
STRAINER
PG PRESSURE GAUGE ERNST TL35P PIPE STEEL CASE - BRONZE TUBE BRASS MOVEMENT - - - - - - - - ACCURACY = 2% OF MIDDLE OF RANGE - USE PRESSURE RANGE SO THAT NEEDLE IS IN MIDRANGE DURING NORMAL OPERATION
PRV PRESSURE REDUCING VALVE - STANDARD WITH BYPASS WATTS LFU5B-Z3 PIPE BRONZE - STAINLESS STEEL SEAT - LEAD FREE WITH STRAINER & BYPASS - - - - LINE SIZE - - 1" UNIT RATED AT 30 GPM AT 15 PSI PRESSURE DROP - MAXIMUM WORKING PRESSURE IS 300 PSI - REDUCED PRESSURE RANGE IS 25 - 75 PSI (ADJUSTABLE)
RCP1 RE-CIRCULATION PLUMBING PUMP TACO 006-B4-2PNP PIPE BRONZE OR STAINLESS STEEL WITH DIGITAL TIMER & AQUASTAT - - - - - - 3 /4" 6 GPM AT 7 FT HEAD - WITH DIGITAL TIMER AND AQUASTAT - PUMP ON 95F, PUMP OFF 115F - 115 VOLT - 1 / 40 HP - CORD & PLUG ELECTRICAL CONNECTION
S1 SINK - DOUBLE COMPARTMENT - PULL OUT FAUCET JUST DL-2133-A-GR COUNTER STAINLESS STEEL MOEN #7560 FAUCET WITH PULL-OUT SPRAY 2" 1 - 1 / 2" 1 / 2" 1 / 2" PROVIDE BRASSCRAFT #KT STOPS - VERIFY DIMENSIONS WITH DRAWINGS PRIOR TO ORDERING - VERIFY HOLE PUNCH REQUIREMENTS - 8" DEEP -
BRASSCRAFT #KTCR STOP
SS1 SERVICE SINK - FLOOR MOUNTED 24" x 24" FIAT MSB 2424 FLOOR MOLDED STONE CONSTRUCTION WITH MOEN #8124 FAUCET 4" 2" 1 / 2" 1 / 2" WITH #832-AA HOSE & HOSE BRACKET, #889-CC MOP HANGER, #E-88-AA STAINLESS STEEL BUMPER GUARD, AND #MSG2424 STAINLESS STEEL WALL GUARD
T1 THERMOMETER - DIAL TYPE - 3" DIAL TRERICE B836 PIPE STAINLESS STEEL ADJUSTABLE ANGLE - - - - - - - - STEM TO CENTER OF PIPE - 3 INCH CASE - 0F TO 100F RANGE FOR COLD WATER - 0F TO 200F RANGE FOR HOT WATER
TP TRAP PRIMER - DIFFERENTIAL PRESSURE WATTS LFTP300 PIPE BRASS - LEAD FREE - EPDM SEALS 695-Y52 SPLITTER IF REQUIRED 1 / 2" - - - - - - DIFFERENTIAL PRESSURE TYPE - ACTIVATES ON 10 PSIG DROP IN PRESSURE - MIN / MAX WORKING PRESSURE IS 30 / 250 PSIG - RUN TUBING TO FLOOR
DRAIN - PROVIDE ACCESS BOX IN WALL
UR URINAL - TOP SPUD - TOUCHLESS - STANDARD HEIGHT KOHLER K-4904-ET WALL / LIP 24" VITREOUS CHINA MOEN #8316 FLUSH VALVE 2" 1 - 1 /2" 3 / 4" - - VITREOUS CHINA 1 / 8 GALLON PER FLUSH URINAL WITH TOP SPUD - STANDARD HEIGHT MOUNTING - BATTERY OPERATED FLUSH VALVE
WCO WALL CLEAN OUT JR SMITH 4432 WALL / 18" STEEL WITH CHROME COVER LINE SIZE - - - - - - CAST IRON CAULK FERULE WITH CASE IRON LEAD SEAL PLUG
WC1 WATER CLOSET - WALL MNTD - ELECT FLUSH - STANDARD HT KOHLER K-4325 WALL / RIM 15" VITREOUS CHINA MOEN #8310DF16 FLUSH VALVE 4" 2" 1" - - PROVIDE JR SMITH #0300 SERIES CARRIER - BATTERY POWERED FLUSH VALVE - (1.0 GALLONS PER FLUSH WHEN LESS THAN 60 SECONDS - 1.6 GALLONS PER FLUSH WHEN LONGER THAN 60 SECONDS) KOHLER #K-4667-C EXTRA HEAVY DUTY ELONGATED OPEN FRONT SEAT
WC2 WATER CLOSET - WALL MNTD - ELECT FLUSH - ADA HEIGHT KOHLER K-4325 WALL / RIM 17" VITREOUS CHINA MOEN #8310DF16 FLUSH VALVE 4" 2" 1" - - PROVIDE JR SMITH #0300 SERIES CARRIER - BATTERY POWERED FLUSH VALVE - (1.0 GALLONS PER FLUSH WHEN LESS THAN 60 SECONDS - 1.6 GALLONS PER FLUSH WHEN LONGER THAN 60 SECONDS) KOHLER #K-4667-C EXTRA HEAVY DUTY ELONGATED OPEN FRONT SEAT
WH1 WALL HYDRANT - NON-FREEZE WOODFORD MODEL 67 WALL / 18" CHROME PLATED FINISH - - - - - - 3 / 4" - - 12" LENGTH OR AS REQUIRED FOR WALL THICKNESS
WHA WATER HAMMER ARRESTOR SIOUX CHIEF 656-E PIPE COPPER - - - - - - 1' 1' MAX WORKING TEMPERATURE 250F - MAX WORKING PRESSURE 350PSIG - 115 TO 155 FIXTURE UNIT VALUE
NOTES: PROVIDE ALL FIXTURES WITH APPROPRIATE COMMERCIAL GRADE SUPPORTS/CARRIERS, P-TRAPS, STOP VALVES, COMMERCIAL GRADE BRAIDED STAINLESS STEEL FLEXIBLE SUPPLIES, UNDER FIXTURE PIPING INSULATION AND WATER HAMMER ARRESTORS. PROVIDE AND INSTALL TRAP PRIMERS FOR ALL FLOOR DRAINS AND FLOOR SINKS UNLESS OTHERWISE INDICATED. INSTALL ALL TRAP PRIMERS IN RECESSED WALL MOUNTED BOXES IN AN ACCESSIBLE LOCATION. FIELD COORDINATE INSTALLATION LOCATION WITH ARCHITECT/ENGINEER. FIELD COORDINATE LOCATION AND NUMBER OF FAUCET MOUNTING HOLES WITH GENERAL CONTRACTOR. INSTALL ALL FIXTURES AS PER THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS.
DOMESTIC COLD WATER (DCW)
DOMESTIC HOT WATER (DHW)
DOMESTIC HOT WATER RECIRC (DHWR)
SANITARY SEWER (SAN)
VENT (V)
FIRE (F)
NATURAL GAS (G)
PLUMBING SYSTEMS LEGEND
PIPE LABEL SCHEDULE
DOMESTIC WATER HEATER SCHEDULE
MARK MFR MODEL
NUMBER
STORAGE
(GAL.)
HEAT
SOURCE
TOTAL
INPUT
(kW)
IMMERSION HEATERS
NO. OF 50A
CONTACTORS TYPE MOUNTING
UNIT PHYSICAL INFORMATION
ADDITIONAL DETAILS
QUANTITY kW HEIGHT DIA.
SHIPPING
WEIGHT (LBS)
DWH1 A.O. SMITH DSE-30 30 ELECTRIC 18 1 18 1 COMMERCIAL 4" CONC PAD 35-3/4" 20-1/2" 150 SEE BELOW
REMARKS:
1. HEAVY DUTY COMERCIAL CONSTRUCTION, 125 PSI WORK PRESS. STANDARD
2. INSULATION: ENTIRE TANK IS SURROUNDED WITH HIGH DENSITY FIBERGLASS
INSULATION, (R12.5) ASHRAE 90.1
3. CABINET: HEAVY GAUGE STEEL WITH HIGH QUALITY POWDER COAT PAINT
4. INTERNALLY GLASS-LINED
5. PRECISE ELECTRONIC CONTROL W/ DIGITAL DISPLAY.
6. ELEMENT SENSING: MONITORED AND DISPLAYED ON SCREEN, ON/OFF, FAILURE.
7. ALL PIPING WITHIN 18" OF WATER HEATER SHALL BE COPPER OR STEEL.
8. PROVIDE ASME TEMPERATURE AND PRESSURE RELIEF VALVES. PIPE TO WITHIN 1" OF FLOOR.
9. PROVIDE TEMPERATURE AND PRESSURE GAUGE.
10. PROVIDE SEISMIC BRACING PER SPECIFICATIONS.
11. PROVIDE SHEET METAL PAN WITH 3/4" SCHEDULE 40 PVC DRAIN TO NEAREST FLOOR DRAIN.
12. THREE YEAR LIMITED WARRANTY
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:0 :1
P
M
P0.1
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
PLUMBING SCHEDULES AND LEGENDS
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
BJK/JTW
TJB
JTW
P
R E E
NI
GN
ELANOISSEF
O R R
EG
ISTERE
D
S
T A
TE OF ID
AH
O
WAVERE
K
TYD
O J
A B
C
UP
KEY NOTES:
PLUMBING GENERAL NOTES:
1. IT IS NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH
OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS,
CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT THIS
PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.
THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS
REQUIRED BY LOCAL CODES.
4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH
OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND
ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR
ADDITIONAL DETAILS NECESSARY FOR COORDINATION.
5. ABSOLUTELY NO FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER
THE CONCRETE SLAB.
6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.
7. PROVIDE TRAP PRIMERS AND TRAP SEALS FOR ALL FLOOR DRAINS.
8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL
FIXTURES.
9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS
TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
10.ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.
A
754321
MECHANICAL
ROOM
BUILDING
STORAGE
ELEV.
FOYER
STORAGE
TEL/COMM
1"ø DCW
DWH1
LHCO
CO
2"DCW
1"DHW
1 2 3 4 5 6 7
D
C
B
4"ø SAN
2"ø SAN
2"ø DCW
4"ø SAN
2"ø DCW
74"ø FP 4"ø FP
1"ø DHW
3/4"DHWR
3/4"ø DHWR
EMR
003A
NOTE:
ALL PIPING SHOWN IS IN
LOWER LEVEL CEILING
BP1
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:0 :1
P
M
P2.0
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
LOWER LEVEL PLUMBING PLAN
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
BJK/JTW
TJB
JTW
: 1/8" = 1'-0"P2.0
9 LOWER LEVEL PLUMBING PLAN
1. VERTICAL PIPE TRANSITION UP, CONTINUED ON PLUMBING PLAN FOR LEVEL
ABOVE. SIZE AND SYSTEM AS NOTED.
2. PROVIDE 1/2" PEX TO FLOOR DRAIN TRAP PRIMER, TYP. ALL FLOOR DRAINS. SEE
DETAIL 9/P9.1.
3. EXTENT OF BASEMENT. PLUMBING BEYOND WILL BE BELOW GRADE AND UNDER
CONCRETE SLAB.
4. REFER TO UNDERFLOOR PLUMBING PLAN P2.1 AT LEVEL ABOVE FOR MORE
INFORMATION REGARDING WASTE AND VENT PIPING.
5. 4" SAN. WASTE THRU CONC. FOUNDATION WALL. PIPE INVERT ELEVATION = 33"
BELOW FINISH FLOOR. FINISH FLOOR ELEVATION = 2255.00'. PIPE INVERT
ELEVATION = 2252.25'. COORDINATE WITH SITE CIVIL CONTRACTOR.
6. 2" DOMESTIC WATER SERVICE LINE THRU CONC. FOUNDATION WALL AT MIN. 6-FT
BELOW FINISHED GRADE ELEVATION.
7. 4" FIRE SPRINKLER WATER SERVICE LINE THRU CONC. FOUNDATION WALL AT
MIN. 6-FT BELOW FINISHED GRADE ELEVATION.
8. RESERVE THIS AREA FOR FIRE SPRINKLER RISER. SHOWN WITH BOLD, DASHED
LINE.
9. 2"CONDENSATE DRAIN, CND FROM FAN COILS CONDENSATE DRAIN LOOP ABOVE.
TIE-IN TO SANITARY SEWER AT SUITABLE LOCATION. REFER TO M2.4 FOR
CONTINUATION. COORDINATE HVAC TRADES.
10.REFER TO DETAIL 1/P9.1 FOR DOMESTIC WATER SERVICE ENTRANCE
REQUIREMENTS.
11.REFER TO DETAIL 2/P9.1 FOR HOT WATER PIPING REQUIREMENTS.
12.ELEVATOR SUMP - SEE DETAIL P9.1.
P
R E E
NI
GN
ELANOISSEF
O R R
EG
ISTERE
D
S
T A
TE OF ID
AH
O
WAVERE
K
TYD
O J
P9.2/P
UP
B
C
R E
F
UP
DN
PF
PF
KEY NOTES:
PLUMBING GENERAL NOTES:
1. IT IS NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH
OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS,
CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT THIS
PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.
THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS
REQUIRED BY LOCAL CODES.
4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH
OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND
ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR
ADDITIONAL DETAILS NECESSARY FOR COORDINATION.
5. ABSOLUTELY NO FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER
THE CONCRETE SLAB.
6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.
7. PROVIDE TRAP PRIMERS AND TRAP SEALS FOR ALL FLOOR DRAINS.
8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL
FIXTURES.
9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS
TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
10.ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.
C.O.
FD1FD1
4"ø SAN4"ø SANLHCO
L1
L1L1
L1
EWC1
WC1
WC1WC1
UR
WC2 WC2SS1
S1
L1
L1
WC1
WC2
WC2
MEDIUM
CONFERENCE
ROOM
ENTRY
VEST.
LARGE
MEETING
ROOM
STORAGE
105A
VESTIBULE/
BREAKOUT
FHP
OFFICE
FHP/BLM
STORAGE
FHP
OPEN
OFFICE
MENS
PUBLIC
RESTROOM
WOMENS
PUBLIC
RESTROOM
ELEC.
CLOS.
MENS
RESTROOM
WOMENS
RESTROOM
SMALL
CONFERENCE
ROOM /
LACTATION
ROOM
BLM
OPEN
OFFICE
BLM
OFFICE
BLM
OFFICE
BLM
OPEN
OFFICE
ELEV.
STAIR
LOBBY
102 MAIL
ROOM
103A
RECEPTION
MEDIUM
CONFERENCE
ROOM
FMO
OPEN
OFFICE
STAIR
BLM
OFFICE
BLM
OFFICE
BLM
OFFICE
BLM
OFFICE
FMO
OFFICE
CIO
OFFICE
PRIVACY
ROOM
BLM
STG.
JAN.
CLOS.
VESTIBULE
LAW
OFFICE
(USFS)
LAW
OFFICE
(USFS)
LAW
OFFICE
(USFS)
LAW
EVIDENCE
ROOM
LAW
OFFICE
(BLM)
LAW
ENFORCEMENT
OPEN
OFFICE
STORAGE
131A
CORRIDOR
113B
WC1
WC1 UR
L1
L1
4"ø SAN
FD1
FD1
FCO
FCO
4"
SAN.
2 2
1 2 3 4 5 6 7
EWC1
BREAKROOM
L1L1
WCO
FCO
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:0 :1
P
M
P2.1
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
FIRST/GROUND LEVEL UNDERFLOOR
PLUMBING PLAN
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
BJK/JTW
TJB
JTW
: 1/8" = 1'-0"P2.1
9 FIRST/GROUND LEVEL UNDERFLOOR PLUMBING PLAN
1. 4" VERTICAL PIPE TRANSITION UP CONTINUED ON SHEET P2.3.
2. PROVIDE 1/2" PEX TO FLOOR DRAIN TRAP PRIMER, TYP. ALL FLOOR DRAINS. SEE
DETAIL 9/P9.1.
3. 4" SAN. WASTE THRU CONC. FOUNDATION WALL. PIPE INVERT ELEVATION = 33"
BELOW FINISH FLOOR. FINISH FLOOR ELEVATION = 2255.00'. PIPE INVERT
ELEVATION = 2252.25'. COORDINATE WITH SITE CIVIL CONTRACTOR. SEE SHEET
P2.0 FOR ADDITIONAL INFORMATION.
4. NEW GAS METER BY SERVICE PROVIDER. SEE CIVIL FOR CONTINUATION.COORD.
W/ LOCAL UTILITY. GAS DEMAND 400-MBh (7-INWC), PROVIDE PULSE SIGNAL TO
OWNER'S MASTER ELECT. METER
P
R E E
NI
GN
ELANOISSEF
O R R
EG
ISTERE
D
S
T A
TE OF ID
AH
O
WAVERE
K
TYD
O J
B
C
R E
F
UP
DN
PF
PF
KEY NOTES:
PLUMBING GENERAL NOTES:
1. IT IS NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH
OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS,
CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT THIS
PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.
THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS
REQUIRED BY LOCAL CODES.
4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH
OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND
ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR
ADDITIONAL DETAILS NECESSARY FOR COORDINATION.
5. ABSOLUTELY NO FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER
THE CONCRETE SLAB.
6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.
7. PROVIDE TRAP PRIMERS AND TRAP SEALS FOR ALL FLOOR DRAINS.
8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL
FIXTURES.
9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS
TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
10.ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.
L1
L1L1
L1
EWC1
WC1
WC1
WC1
UR
WC2 WC2
SS1
MEDIUM
CONFERENCE
ROOM
ENTRY
VEST.
LARGE
MEETING
ROOM
STORAGE
105A
VESTIBULE/
BREAKOUT
FHP
OFFICE
144 FHP/BLM
STORAGE
FHP
OPEN
OFFICE
MENS
PUBLIC
RESTROOM
WOMENS
PUBLIC
RESTROOM
ELEC.
CLOS.
MENS
RESTROOM
WOMENS
RESTROOM
BREAKROOM
SMALL
CONFERENCE
ROOM /
LACTATION
ROOM
BLM
OPEN
OFFICE
BLM
OFFICE
BLM
OFFICE
BLM
OPEN
OFFICE
ELEV.
STAIR
LOBBY
ROOM
103A
RECEPTION
MEDIUM
CONFERENCE
ROOM
FMO
OPEN
OFFICE
STAIR
BLM
OFFICE
BLM
OFFICE
BLM
OFFICE
BLM
OFFICE
FMO
OFFICE
CIO
OFFICE
PRIVACY
ROOM
BLM
STG.
JAN.
CLOS.
VESTIBULE
LAW
OFFICE
(USFS)
LAW
OFFICE
(USFS)
LAW
OFFICE
(USFS)
LAW
EVIDENCE
ROOM
LAW
OFFICE
(BLM)
LAW
ENFORCEMENT
OPEN
OFFICE
STORAGE
131A
CORRIDOR
113B
WC2
WC2
WC1 WC1
WC1 UR
L1
L1
L1
L1
FD1
FD1
IM1
FD1FD1 1 1/2"ø DCW
1 1/2"ø DCW 3/4"ø DHW
3/4"ø DCW
2-1/2"V
2"DCW
2 1/2"V
S1
6 1"DHW
1 2 3 4 5 6 7
3/4"ø DHW
EWC1
L1L1
3/4"ø DHWR
3/4"DHWR
3/4"ø DHWR
1 1/2"ø DCW
1 1/2"ø DCW
WHA
WHA
WH1
3/4"ø DCW
3/4"ø DCW
WH1
WH1
3/4"ø DCW
BV
BV
BV
WH1
1 1/2"ø V
3/4"ø DCW
1/2"ø DHW 3/4"ø DCW
3/4"ø DHWR
BV
TP
TP 2"ø V
1 1/2"ø DCW
2" ø
V
TYP.
BV
TYP.
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:0 :2
P
M
P2.2
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
FIRST/GROUND LEVEL PLUMBING PLAN
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
BJK/JTW
TJB
JTW
: 1/8" = 1'-0"P2.2
9 FIRST/GROUND LEVEL PLUMBING PLAN
1. VERTICAL PIPE TRANSITION UP, CONTINUED ON PLUMBING PLAN P2.4. SIZE AND
SYSTEM AS NOTED.
2. PROVIDE 1/2" PEX TO FLOOR DRAIN TRAP PRIMER, TYP. ALL FLOOR DRAINS. SEE
DETAIL 9/P9.1.
3. HOT & COLD WATER DOWN IN INTERIOR WALL TO UNDER CABINETRY & OVER TO
COUNTER-MOUNTED SINK.
4. CW PIPING TO REFRIGERATOR ICE-MAKE BOX.
5. 2"CONDENSATE DRAIN, CND DOWN IN PLUMBING CHASE TO BASEMENT. REFER TO
P2.0 FOR CONTINUATION. COORDINATE HVAC TRADES.
6. VERTICAL PIPE TRANSITION UP AND DOWN, CONTINUED ON P2.0 AND P2.4. SIZE
AND SYSTEM AS NOTED.
P
R E E
NI
GN
ELANOISSEF
O R R
EG
ISTERE
D
S
T A
TE OF ID
AH
O
WAVERE
K
TYD
O J
DN
A B
C
R E
F
PF
KEY NOTES:
PLUMBING GENERAL NOTES:
1. IT IS NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH
OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS,
CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT THIS
PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.
THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS
REQUIRED BY LOCAL CODES.
4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH
OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND
ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR
ADDITIONAL DETAILS NECESSARY FOR COORDINATION.
5. ABSOLUTELY NO FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER
THE CONCRETE SLAB.
6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.
7. PROVIDE TRAP PRIMERS AND TRAP SEALS FOR ALL FLOOR DRAINS.
8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL
FIXTURES.
9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS
TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
10.ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.
FWS
ASST.
STATE
SUPERINTENDENT
OFFICE
FWS
OFFICE
STORAGE
FWS
OFFICE
FWS
OFFICE
FWS
OPEN
OFFICE
NEPA
PLANNER
OPEN
OFFICE
ECO
OPEN
OFFICE
SMALL
CONFERENCE
ROOM
FWS
OFFICE
SECURITY
OFFICE
ECO
OFFICE
PUBLIC
AFFAIRS
OFFICER
HRM
OFFICE
VEG
OFFICE
TEC
OFFICE
NIZ
OFFICE
MEDIUM
CONFERENCE
ROOM
ROOM
BREAK
ROOM
MENS
RESTROOM
WOMENS
RESTROOM
ELEV
AQM
OPEN
OFFICE
DEPUTY
SUP.
OFFICE
SUPERVISORS
OFFICE
SUPERVISOR
FILING
MEDIUM
CONFERENCE
ROOM
EXECUTIVE
ASSISTANT/
WAITING
VEG
OPEN
OFFICE
TEC
OPEN
OFFICE
HRM
OPEN
OFFICE
STAIR
LARGE
CONFERENCE
ROOM
STAIR
CORRIDOR
210A
WC2
WC2
WC1 WC1
WC1 UR
L1
L1
L1
L1
S1
CO
FD1
FD1
1 2 3 4 5 6 7
2 1/2" V1
4"
SAN.
4"ø SAN
EWC1
2 1/2" V
FCO
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:0 :2
P
M
P2.3
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SECOND LEVEL UNDERFLOOR PLUMBING
PLAN
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
BJK/JTW
TJB
JTW
: 1/8" = 1'-0"P2.3E7.2
9 SECOND LEVEL UNDERFLOOR PLUMBING PLAN
1. VERTICAL PIPE TRANSITION UP AND/OR DOWN, CONTINUED ON SHEET P2.4 & P2.2.
SIZE AND SYSTEM AS NOTED.
2. PROVIDE 1/2" PEX TO FLOOR DRAIN TRAP PRIMER, TYP. ALL FLOOR DRAINS. SEE
DETAIL 9/P9.1.
P
R E E
NI
GN
ELANOISSEF
O R R
EG
ISTERE
D
S
T A
TE OF ID
AH
O
WAVERE
K
TYD
O J
DN
A B
C
R E
F
PF
FWS
ASST.
STATE
SUPERINTENDENT
OFFICE
FWS
OFFICE
STORAGE
FWS
OFFICE
FWS
OFFICE
FWS
OPEN
OFFICE
NEPA
PLANNER
OPEN
OFFICE
ECO
OPEN
OFFICE
SMALL
CONFERENCE
ROOM
FWS
OFFICE
SECURITY
OFFICE
ECO
OFFICE
PUBLIC
AFFAIRS
OFFICER
HRM
OFFICE
VEG
OFFICE
TEC
OFFICE
NIZ
OFFICE
MEDIUM
CONFERENCE
ROOM
ROOM
BREAK
ROOM
MENS
RESTROOM
WOMENS
RESTROOM
ELEV
AQM
OPEN
OFFICE
DEPUTY
SUP.
OFFICE
SUPERVISORS
OFFICE
SUPERVISOR
FILING
MEDIUM
CONFERENCE
ROOM
225EXECUTIVE
ASSISTANT/
WAITING
VEG
OPEN
OFFICE
TEC
OPEN
OFFICE
HRM
OPEN
OFFICE
STAIR
LARGE
CONFERENCE
ROOM
WC2
WC2
WC1 WC1
WC1 UR
L1
L1
L1
L1
IM1
BVBV
2-1/2"V
FD1
FD1
S1
1-1/2"DCW
3/4"DHW,
3/4"DHWR
EWC1
2 1/2"V
3/4"ø DHWR 3/4"ø DHW 1 1/2"ø DCW
3/4"ø DHW 3/4"ø DHWR
1 1/2"ø DCW
3/4"ø DCW
WHA
1 1/2"ø V
KEY NOTES:
PLUMBING GENERAL NOTES:
1. IT IS NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH
OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS,
CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT THIS
PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.
THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS
REQUIRED BY LOCAL CODES.
4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH
OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND
ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR
ADDITIONAL DETAILS NECESSARY FOR COORDINATION.
5. ABSOLUTELY NO FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER
THE CONCRETE SLAB.
6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.
7. PROVIDE TRAP PRIMERS AND TRAP SEALS FOR ALL FLOOR DRAINS.
8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL
FIXTURES.
9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS
TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
10.ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:0 :2
P
M
P2.4
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SECOND LEVEL PLUMBING PLAN
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
BJK/JTW
TJB
JTW
: 1/8" = 1'-0"P2.4E7.2
9 SECOND LEVEL PLUMBING PLAN
1. VERTICAL PIPE TRANSITION UP AND/OR DOWN, CONTINUED ON PLUMBING PLAN
FOR LEVEL ABOVE AND/OR BELOW. SIZE AND SYSTEM AS NOTED.
2. PROVIDE 1/2" PEX TO FLOOR DRAIN TRAP PRIMER, TYP. ALL FLOOR DRAINS. SEE
DETAIL 9/P9.1.
3. HOT & COLD WATER DOWN IN INTERIOR WALL TO UNDER CABINETRY & OVER TO
COUNTER-MOUNTED SINK.
4. CW PIPING TO REFRIGERATOR ICE-MAKE BOX
P
R E E
NI
GN
ELANOISSEF
O R R
EG
ISTERE
D
S
T A
TE OF ID
AH
O
WAVERE
K
TYD
O J
N.T.S.
N.T.S. N.T.S. N.T.S.
N.T.S. N.T.S. N.T.S. N.T.S.
N.T.S.
CLEANOUT
TEE
FLOOR
LINE
CONNECT TO WASTE
LINE
STAINLESS STEEL
WALL COVER
AND SCREW
WALL
EXTEND WASTE OR
VENT LINE WHERE
INDICATED
M
IN
HANGER ROD
TURN BUCKLE (AS
REQUIRED)
INSULATION
PIPE
SHEET METAL
SADDLE
INSERT
CLEVIS TYPE HANGER
FOR PIPE 2" & LARGER
HANGER ROD
TURN
BUCKLE (AS
REQUIRED)
INSULATION
PIPE
SHEET
METAL
SADDLE
INSERT
PIPE STRAP TYPE
HANGER FOR PIPE
LESS THAN 2"
GFI OUTLET
FINISHED
FLOOR
ELECTRICAL
POWER CORD
2'X2'X2' SUMP PIT WITH GRATE COVER
(AT CONTRACTORS OPTION:
PROVIDE A FIBERGLASS BASIN WITH
COVER SUITABLE FOR SUMP PUMP)
ELEVATOR
SHAFT FLOOR
CHECK VALVE
SUMP PUMP:
MANUAL OPERATION
10' POWER CORD 115V
ELECTRICAL SWITCH
FINISHED
FLOOR
TERMINATE SUMP PUMP
DISCHARGE ABOVE
FINISHED FLOOR
ELEVATION WITH 3/4" HOSE
BIBB CONNECTION
1" PVC OR COPPER
DISCHARGE
A.S.M.E. T&P
RELIEF VALVE
PIPE RELIEF VALVE
DISCHARGE LINE FULL SIZE
TO FLOOR DRAIN OR
APPROVED RECEPTOR
SEISMIC BRACING PER
CODE
4" CONCRETE HOUSE
KEEPING PAD
DWH1
MANUAL FLOW BALANCE
VALVE (TYP)
DCW
120° DHW
3/4"DHWR
T
RECIRC PUMP, RCP1
TEMP GAUGE, T1 (TYP)
CHECK VALVE (TYP)
THERMOSTATIC MIXING VALVE
(SET TO 120°F)
STRAINER
1" C
W P
DHW
T&P PORT (TYP)
PRESSURE GAUGE, PG1
140° HW
1" DCW
NOTE:
PIPE THERMOSTATIC MIXING VALVE
AS PER MANUFACTURER'S WRITTEN
INSTALLATION INSTRUCTIONS
ET1
MV1
INTERIOR FLOOR CLEANOUTEXTERIOR CLEANOUT
(LIGHT TRAFFIC AREA)
SEE
PLANS
FINISHED FLOOR
DIRECTION OF FLOW
CAST IRON EXTENTION -
SAME SIZE AS SEWER UPT
TO 4" DIA.
6" THICK BY 18" SQUARE
CONCRETE PAD
"CO" TO BE CAST IN COVER
GRADE OR PAVING
CAST IRON CLEANOUT WITH
COVER FOR DUTY REQUIRED
CAST IRON LONG SWEEP 1/4
BEND OR CAST IRON COMB,
"Y" & 1/8 BEND. (USE
REDUCING TYPE WHERE
REQUIRED)
BUILDING DRAINING OR SEWER MATERIAL
AND SIZE AS SPECIFIED
1/2'' CW TO TRAP
CONNECT AS REQ'D
FIN FLOOR
1/2'' CW
UNION
FRAMED WALL
1/2'' BV
PVC SLEEVE
NOTE:
TRAP PRIMERS ARE
REQUIRED AT ALL
FLOOR DRAINS.
MOUNT PIPE IN
INTERIOR WALL
3/4" CW
SUPPLY
FREEZELESS WALL
HYDRANT WITH
VACUUM BREAKER
18" ABOVE FINISHED
GRADE OR AS NOTED
ON SCHEDULE
TRANSITION HDPE
TO COPPER
FOUNDATION WALL
DCW SERVICE -
SEE CIVIL DRAWINGS
FOR CONTINUATION
PIPE AIR GAP TO DRY WELL
BYPASS WITH LOCKING HANDLE
STRAINER
REDUCED PRESSURE BACKFLOW PREVENTOR ( BP1)
BALL VALVE (BV1) - TYP.
PRESSURE REDUCING VALVE ( PRV1)
DCW TO BUILDING
PRESSURE GAUGE ( PG1) - TYP.
WATER METER WITH PULSE SIGNAL FOR MONITORING
NOTES:
1. REMOTE WATER METER READER(S) LOCATED AS DIRECTED BY UTILITY.
2. COORDINATE TIE-IN TO OWNER'S WATER
MONITORING SYSTEMS.
1 WATER SERVICE ENTRANCE
P9.1
2 WATER HEATER
P9.1
3 THERMOSTATIC MIXING VALVE
P9.1
4 FREEZELESS WALL HYDRANT
P9.1
5 WALL CLEANOUT
P9.1
6 FLOOR CLEANOUT
P9.1
7 PIPE HANGER
P9.1
8 TRAP PRIMER - IN FINISHED LOCATION
P9.1
1" DOMESTIC HOT
WATER TO BUILDING
1" DOMESTIC HOT WATER FROM
WATER HEATER, ISOLATE WITH
BALL VALVE
1" DOMESTIC COLD WATER
FROM SERVICE, ISOLATE W/
BALL VALVE
MIXED WATER TEMPERATURE
DISPLAY
9 ELEVATOR SUMP
P9.1
TRAP PRIMER IN
WALL BOX. SECURE
TO WALL FRAMING
"LOCKABLE" ACCESS
PANEL - COORDINATE
LOCATION W/ ARCHITECT
CONNECT TO
CW PIPE IN WALL
FLOOR DRAIN W/ TRAP
PRIMER CONNECTION
NOTES:
1. PROVIDE REMOTE WATER METER READER AND LOCATE AS REQUIRED BY LOCAL UTILITY.
2. PROVIDE LOCKING SHUTOFF VALVES ON BYPASS LINE. BYPASS LINE MAY BE SMALLER THAN MAIN LINE
(GENERALLY 1/2 MAIN LINE). BYPASS MUST HAVE SAME TYPE OF BACKFLOW PROTECTION AS MAIN LINE.
3. BACK FLOW PREVENTERS SHALL BE MOUNTED 18" MIN ABOVE FLOOR AND NO MORE THAT 48" MAX
ABOVE FLOOR MIN. 6" FROM WALLS, ETC. MUST BE ACCESSIBLE WITH NO OBSTRUCTIONS
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:0 :2
P
M
P9.1
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
PLUMBING DETAILS
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
BJK/JTW
TJB
JTW
P
R E E
NI
GN
ELANOISSEF
O R R
EG
ISTERE
D
S
T A
TE OF ID
AH
O
WAVERE
K
TYD
O J
PS
FS
TS
FAA SS
FACP SD
D SD
D
F H
F
S Sxx WP
Sx SC
X
D-1
PS-X
X
X
X
X
J
TV
X
LP100
208/120V 3#. 4W
M
M
M
SPD VFD
LA
PFC G
M CB
Y
CR EL
RE MD
DC GB
ES C
KP s
S
X
OS
DT
OS
DT
P
DT
OS R1
P R2
LV R3
R4
PROJECT NOTES:
1. THIS PROJECT IS PART OF A PHASED PROJECT. MANY ELECTRICAL SYSTEMS MUST BE
ABLE TO INTEGRATE WITH THE EXISTING SYSTEMS, INCLUDING BUT NOT LIMITED TO FIRE
ALARM, ELECTRICAL METERS, SECURITY, INTERCOM. SEE DETAILS FOR MORE
INFORMATION.
2. PRIOR TO BID CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK REQUIRED TO
COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL
BECOME THOROUGHLY FAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETE THE
PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL ELECTRICAL
SERVICE WORK WITH UTILITY. OWNER PAYS ALL FEES, CONTRACTOR DOES ALL
SCHEDULING AND COORDINATION OF WORK. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO ENSURE ALL SCHEDULES ARE MET.
4. GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE
WITH NECA 1, "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL
CONTRACTING." THIS PUBLICATION IS AVAILABLE FROM NECA BY TELEPHONE AT
301-657-3110 OR ON-LINE AT WWW.NECANET.ORG.
5. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH MECHANICAL FOR
PLENUM SPACES AND PROVIDE PLENUM RATED CABLES WHERE REQUIRED FOR LIGHTING
CONTROL, DATA, FIRE ALARM AND ALL OTHER L.V. SYSTEMS NOT INSTALLED IN CONDUIT.
VERIFY CONDUIT REQUIREMENTS ON DRAWINGS AND SPECIFICATIONS.
6. FIRE-RESISTANCE: PROVIDE A MINIMUM HORIZONTAL DISTANCE OF 24" BETWEEN OUTLET
BOXES LOCATED ON OPPOSITE SIDES OF FIRE-RESISTANCE RATED WALLS. WHERE THIS IS
NOT POSSIBLE INSTALL UL LISTED PUTTY PADS ON ALL OUTLET BOXES NOT MEETING THE
24" SEPARATION. PROVIDE A UL LISTED THROUGH -PENETRATION FIRESTOP FOR
PENETRATIONS OF FIRE-RESISTANCE RATED ASSEMBLIES.
7. CONDUCTORS ARE SIZED PER THE 75 DEGREE C RATING COLUMN OF NEC TABLE 310.16. IF
THE TERMINAL USED FOR A TERMINATION OF A PARTICULAR CONDUCTOR IS NOT MARKED,
OR THE TERMINAL IS MARKED FOR 60 DEGREE C CONDUCTORS, IT IS THE RESPONSIBILITY
OF THE CONTRACTOR TO EITHER ADJUST THE AMPACITY OF THE CONDUCTOR TO MATCH
THE 60 DEGREE COLUMN OF TABLE 310.16, OR REPLACE THE TERMINAL WITH ONE RATED
FOR AT LEAST 75 DEGREES C
8. BASED ON ACTUAL HOMERUN LENGTHS REQUIRED IN THE FIELD, THE CONTRACTOR SHALL
CALCULATE AND INCREASE THE WIRE SIZES AS REQUIRED TO LIMIT BRANCH CIRCUIT
VOLTAGE DROP TO 3%. FOR 20A BRANCH CIRCUITS THE MINIMUM CONDUCTOR SIZES
SHALL BE AS FOLLOWS: #10 AWG CU FOR RUNS BETWEEN 100 TO 200 LINEAR FEET, #8
AWG CU FOR RUNS BETWEEN 200 AND 325 LINEAR FEET, AND AS CALCULATED BY THE
CONTRACTOR FOR CIRCUITS EXTENDING BEYOND 325 LINEAR FEET. IN ALL CASES WHERE
WIRE SIZES INCREASE, THE CONTRACTOR SHALL PROVIDE LARGER CONDUITS AS
REQUIRED.
9. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V BRANCH CIRCUIT.
ABBREVIATIONS
A or AMP AMPERES
AC ALTERNATING CURRENT
A/C AIR CONDITIONING
AF AMP FUSE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AL ALUMINUM
AS AMP SWITCH
ATS AUTOMATIC TRANSFER SWITCH
BAS BUILDING AUTOMATION SYSTEM
BKR BREAKER
C RACEWAY/CONDUIT
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CLG CEILING
C.O. RACEWAY/CONDUIT ONLY, WITH PULL STRING
CNTRL CONTROL
CR CARD READER
CU COPPER
DISC DISCONNECT
DIST DISTRIBUTION
DPDT DOUBLE POLE DOUBLE THROW
DWG DRAWING
EA EACH
EF EXHAUST FAN
ELEC ELECTRIC
EMT ELECTRICAL METALLIC TUBING
EQUIP EQUIPMENT
EX OR
EXIST
EXISTING
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FATC FIRE ALARM TERMINAL CABINET
FD FUSED DISCONNECT
FLR FLOOR
FO FIBER OPTIC
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
GEC GROUNDED ELECTRODE CONDUCTOR
GFI GROUND FALUT INTERRUPTER
GND GROUND
GRC GALVANIZED RIGID CONDUIT
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HTR HEATER
HVAC HEATING, VENTILATING & AIR CONDITIONING
HZ HERTZ
J-BOX JUNCTION BOX
KVA KILOVOLT AMPERES
KW KILOWATTS
LTG LIGHTING
LPW LUMENS PER WATT
MAG MAGNETIC STARTER
MAN MANUAL
MAX MAXIMUM
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MH METAL HALIDE
MIN MINIMUM
MSS
MOTOR STARTER SWITCH WITH THERMAL
OVERLOADS
N NEUTRAL
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA
NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NFD NON-FUSED DISCONNECT
NIC NOT IN CONTRACT
NO NORMALLY OPEN
# NUMBER
OAE OR APPROVED EQUAL
OC ON CENTER
OCPD OVERCURRENT PROTECTION DEVICE
OH OVERHEAD
P POLE
PB PUSHBUTTON
PNL PANEL
PoE POWER-OVER-ETHERNET
PVC POLYVINYL CHLORIDE CONDUIT
PWR POWER
RECEPT RECEPTACLE
RCPT RECEPTACLE
RGS RIGID GALVANIZED STEEL
RM ROOM
RVNR REDUCED VOLTAGE NON-REVERSING
SP SINGLE POLE TOGGLE SWITCH
SPEC SPECIFICATION
SPST SINGLE POLE SINGLE THROW
SSPB START-STOP PUSHBUTTON
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TB TELEPHONE BOARD
TC TIME CLOCK
TD TIME DELAY
TEL TELEPHONE
TSP TWISTED SHIELDED PAIR
TTB TELEPHONE TERMINAL BOARD
TYP TYPICAL
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UON UNLESS OTHERWISE NOTED
V VOLT
VA VOLT AMPERES
VFD VARIABLE FREQUENCY DRIVE
W WATTS
WAO WORK AREA OUTLET
WP WEATHERPROOF
W/O WITHOUT
XFMR TRANSFORMER
Y WYE CONNECTED
DELTA CONNECTED
PHASE
*THESE ABBREVIATIONS COMPRISE A STANDARD LIST;
NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT.
ELECTRICAL SYMBOL LEGEND: SYSTEM PLANS
SYMBOL DESCRIPTION DESCRIPTION SYMBOL
TELEPHONE OUTLET; PROVIDE ROUGH IN ONLY. 2-GANG
BOX W/MUD RING AND 1" STUBBED UP TO ACCESSIBLE
CEILING SPACE. (MOUNT AT +18" AFF. UNO.)
SPRINKLER PRESSURE SWITCH
VOICE-DATA OUTLET; PROVIDE ROUGH IN ONLY. 2-GANG
BOX W/MUD RING AND 1" STUBBED UP TO ACCESSIBLE
CEILING SPACE. (MOUNT AT +18" AFF. UNO.)
SPRINKLER FLOW SWITCH
CABLE TRAY OR BASKET TRAY. SEE SYSTEMS PLANS FOR
DIMENSIONS AND MOUNTING HEIGHT.
SPRINKLER TAMPER SWITCH
FIRE ALARM ANNUNCIATOR PANEL
SINGLE-STATION SMOKE DETECTOR. PROVIDE 120V AND
MONITOR AT FACP VIA RELAY
FIRE ALARM CONTROL PANEL SMOKE DETECTOR - PHOTO-ELECTRIC
DOOR HOLDER
SMOKE DETECTOR "D" INDICATES DUCT SMOKE
DETECTOR.
FIRE ALARM MANUAL STATION (MOUNT AT +46" AFF, UNO.) HEAT DETECTOR
STROBE WALL MOUNT (MOUNT AT +82" AFF, UNO.) AND
CEILING MOUNT
HORN/STROBE WALL MOUNT (MOUNT AT +82" AFF, UNO.)
AND CEILING MOUNT
SPEAKER - CEILING MOUNT, WALL MOUNT (SEE GENERAL
NOTE "D" ON PLANS FOR SPEAKER NOTATIONS. MODEL
NUMBERS ARE GIVEN ON SHEET E9.5)
WIRELESS POINT CONNECTION:
SUPPLY CAT6 CABLING TO THIS LOCATION (CLG).
SPEAKER - SUSPEND FROM CEILING (SEE GENERAL NOTE
"D" ON PLANS FOR SPEAKER NOTATIONS. MODEL NUMBERS
ARE GIVEN ON SHEET E9.5)
SPEAKER CONTROLLER
ELECTRICAL SYMBOL LEGEND: POWER PLANS
SYMBOL DESCRIPTION DESCRIPTION SYMBOL
BRANCH CIRCUIT PANELBOARD RACWAY STUB-OUT OR STUB-UP WITH CAPPED END
PANEL AND CIRCUIT DESIGNATION ARE SHOWN NEXT
TO EACH DEVICE (PANEL NAME - CIRCUIT NUMBER).
BRANCH CIRCUIT WIRE SIZE IS #12 UNLESS NOTED
OTHERWISE. A SINGLE INSULATED GREEN GROUND
CONDUCTOR SHALL BE PROVIDED WITH EACH HOME
RUN. PROVIDE A SEPARATE NEUTRAL FOR EACH
CIRCUIT. HOME RUNS SHALL HAVE NO MORE THAN
THREE CIRCUITS. LINE VOLTAGE AND LOW VOLTAGE
WIRING IS NOT SHOWN ON PLANS. FOR EQUIPMENT
CIRCUITING, SEE MEP COORDINATION SCHEDULE.
SURFACE MOUNTED PLUGSTRIP. SUBSCRIPT DENOTES
TYPE AND STYLE. SEE TABLE BELOW:
TYPE A: PLUGSTRIP, POWER ONLY, OUTLET EVERY 3' OC
TYPE B: WIREMOLD SERIES 4000 POWER AND DATA
TYPE C: WIREMOLD SERIES 5400 POWER AND DATA
DUPLEX RECEPTACLE. (MOUNT AT +18" AFF. UNO.)
X-GFI-GFCI RECEPTACLE
WP-WEATHER PROOF WITH WHILE IN USE COVER
4PLEX RECEPTACLE. (MOUNT AT +18" AFF. UNO.)
X-GFI-GFCI RECEPTACLE
WP-WEATHER PROOF WITH WHILE IN USE COVER
LINE BREAK
ABOVE COUNTER DUPLEX RECEPTACLE MOUNTED 4"
ABOVE BACKSPLASH
SURFACE MOUNTED RACEWAY
ABOVE COUNTER 4PLEX RECEPTACLE MOUNTED 4"
ABOVE BACKSPLASH
RACEWAY CONCEALED IN WALL, FLOOR, OR CEILING IN
FINISHED SPACES, EXPOSED IN UNFINISHED
SPACES.
FLOOR OUTLET - HUBBEL MODEL #HBLCFB401CB
WITH COVER MODEL #HBLTCGNTBKSW, OR EQUAL.
RACEWAY BELOW FLOOR OR BELOW GRADE
FLOOR BOX WITH COMBINATION 4PLEX RECEPTACLE
AND 2 TELEPHONE/DATA OUTLETS. USE EVOLUTION
SERIES 8AT, OR EQUAL.
RACWAY STUB-OUT OR STUB-UP WITH BUSHED END
JUNCTION BOX GROUNDING BUS
FLATSCREEN TV BOX; 2-GANG, FLUSH IN WALL,
HUBBELL RACO NSAV62M WITH NSAV6C COVER.
DUPLEX RECEPTACLE AND SINGLE GANG DATA PORT
AND ALL CCTV CABLE CONNECTIONS. (MOUNT AT
+72" AFF. UNO.)
PUSHBUTTON (MOUNT AT +54" AFF, UNO.)
-EPO EMERGENCY POWER OFF
-ADA HANDICAP ACCESSIBLE DOOR (DEVICE BY OTHERS)
-ODO OVERHEAD DOOR OPERATOR (DEVICE BY OTHERS)
SPECIAL PURPOSE OUTLET.
(MOUNT AT +18" AFF. UNO.)
POWERED FURNITURE CONNECTION
1. THESE SYMBOLS COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT.
2. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR. MOUNTING HEIGHTS INDICATED ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGS OR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED.
ELECTRICAL SYMBOL LEGEND: 1-LINES
SYMBOL DESCRIPTION DESCRIPTION SYMBOL
SWITCH BOARD OR PANEL BOARD; NAME, VOLTAGE,
PHASE, NUMBER OF WIRES WHEN INDICATED
DISCONNECT SWITCH ("XXAS' = SWITCH AMP RATING)
CT AND CUSTOMER POWER METER
FUSED DISCONNECT SWITCH ("XXAS/XXAF" - SW AND FUSE
AMP RATING)
MOTOR SYMBOL
COMBINATION MOTOR STARTER (STR SIZE, TYPE, AS, AF,
SEE MEP COORD. SCHEDULE)
UTILITY ELECTRIC METER AND BASE (BASE BY
CUSTOMER)
AUTOMATIC TRANSFER SWITCH
SURGE PROTECTION DEVICE VARIABLE FREQUENCY DRIVE
LIGHTNING ARRESTOR FIXED MOUNT LV BREAKER
STRESS RELIEF CONE FUSED SWITCH ("XXAS/XXAF" = SW AND FUSE AMP RATING)
POWER FACTOR CORRECTION CAPACITOR GENERATOR
MOTOR STARTER SWITCH WITH THERMAL OVERLOADS WALL MOUNTED BREAKER
CONTRACTOR NORMALLY OPEN, NORMALLY CLOSED THERMAL OVERLOAD ELEMENT
TRANSFORMER
3-PHASE, 3-WIRE DELTA CONNECTION Δ
3-PHASE, 4 WIRE GROUNDED WYE CONNECTION
ELECTRICAL SYMBOL LEGEND: SECURITY SYSTEMS
SYMBOL DESCRIPTION DESCRIPTION SYMBOL
CARD READER (SEE ELECTRICAL DETAILS FOR
REQUIREMENTS.)
ELECTRIC LOCK
REQUEST TO EXIT MOTION DETECTOR MOTION DETECTOR
DOOR CONTACTS GLASS BREAK DETECTOR
ELECTRIC STRIKE
CEILING MOUNT CCTV CAMERA - PROVIDE CAT6 IN 1" C.
FOR ALL CAMERA LOCATIONS. SEE ELECTRICAL DETAILS
FOR SYSTEM REQUIREMENTS.
KEY PAD SECURITY SPEAKER/ALARM
SECURITY STROBE/ALARM
ELECTRICAL SYMBOL LEGEND: LIGHTING PLANS
SYMBOL DESCRIPTION DESCRIPTION SYMBOL
1X4 SURFACE WALL MOUNT FLUORESCENT PENDANT FIXTURE; HIGH BAY, LOW BAY, DECORATIVE.
1X4 2X2 2X4 RECESSED FLUORESCENT, 'a', AND 'b'.DESIGNATES SWITCH LEGS.
EXIT SIGN. ARROW(S) INDICATE DIRECTION OF TRAVEL,
SHADED AREA INDICATES ILLUMINATED FACE(S). STEM
INDICATES WALL MOUNTED. CELING MOUNTED
OTHERWISE.
1X4 2X2 2X4 RECESSED EMERGENCY FLUORESCENT,
'a', AND 'b'.DESIGNATES SWITCH.
EMERGENCY EGRESS BATTERY PACK, WALL MOUNT OR
CEILING MOUNT
1X4 2X2 2X4 SURFACE OR PENDANT FLUORESCENT,
'x' DESIGNATES SWITCH LEG.
WALL MOUNTED SCONCE OR WALLPACK FIXTURE
1X4 2X2 2X4 SURFACE OR PENDANT EMERGENCY
FLUORESCENT, 'x' DESIGNATES SWITCH LEG.
SURFACE MOUNTED DOWNLIGHT
4' FLUORESCENT STRIP OR INDUSTRIAL, SURFACE
OR CHAIN HUNG
RECESSED CAN DOWNLIGHT
POLE MOUNTED FIXTURE RECESSED CAN WALLWASHER
LIGHTED BOLLARD
TRACK LIGHTING. SEE FIXTURE SCHEDULE AND
LIGHTING PLANS.
STANDARD LIGHTING CONTROLS: SWITCHES AND LINE VOLTAGE DIMMERS
TOGGLE SWITCH (MOUNT AT 46" AFF. UNO.)
SUBSCRIPTS:
X- SINGLE POLE
3- THREE-WAY
4- FOUR-WAY
D- DIMMER SWITCH - PHILIPS SUNRISE DIMMER -
ON/OFF.
K- KEYED SWITCH
SUBSCRIPTS: (CONTINUED)
T- TIMER
P- PILOT LIGHT
OS-WALL SWITCH OCC SENSOR. WATTSTOPPER
DW100(SINGLE SWITCH OR DW-200 DUAL SWITCH).
a- SINGLE POLE LIGHTING SWITCH FOR ZONE a b- SINGLE POLE LIGHTING SWITCH FOR ZONE b ab- LIGHTING SWITCHES WITH MULTIPLE ZONES
CEILING MOUNT OCCUPANCY SENSOR. WATT
STOPPER DT-300 DUAL TECHNOLOGY CEILING
MOUNT OR EQUAL WITH BZ-50 POWER PACKS AS
NEEDED.
WALL MOUNT OCCUPANCY SENSOR. WATT STOPPER
DT-200 DUAL TECHNOLOGY WALL MOUNT OR EQUAL
WITH BZ-50 POWER PACKS AS NEEDED.
PHOTOCELL. WATT STOPPER LS-301 CEILING MOUNT
OR EQUAL
DIGITAL LIGHTING CONTROLS: ROOM CONTROLLERS AND LOW VOLTAGE DEVICES
OCCUPANCY SENSOR. WATT STOPPER LMDC-100
DUAL TECHNOLOGY CEILING MOUNT OR EQUAL
ROOM CONTROLLER. WATT STOPPER DLM LMRC-101 OR
EQUAL.
PHOTOCELL. WATT STOPPER DLM LMLS-400 CEILING
MOUNT OR EQUAL
ROOM CONTROLLER. WATT STOPPER DLM LMRC-102 OR
EQUAL.
LOW VOLTAGE SWITCH; WATTSTOPPER LMSW-10X,
"X" DENOTES NUMBER OF BUTTONS
DIMMING ROOM CONTROLLER. WATT STOPPER DLM
LMRC-212 OR EQUAL.
DIMMING ROOM CONTROLLER. WATT STOPPER DLM
LMRC-213 OR EQUAL.
16147
P R
O
FE
SS IONAL ENG INEE
RL
I C E N S ED
S T
A
T E O F I D
A H
O
A R
I AN
C . B LOOMF
I E L
D
OFFICE BIDDING OPTIONS
• BASE BID: PHASE 3 - OFFICE.
• OPTION ITEM #1: INFORMATION BUILDING
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:3 :4
P
M
E0.1
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SYMBOLS & ABBREVIATIONS
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
RJH
BMM
ACB
16147
P R
O
FE
SS IONAL ENG INEE
RL
I C E N S ED
S T
A
T E O F I D
A H
O
A R
I AN
C . B LOOMF
I E L
D
A B
C
R E
F
R E
F
G
G
D
Y
H
D
YH
D
YH
E5E5E5E5
TO TEL/COMM RM 002
TO BUILDING SERVICE DISCONNECT
TO PANEL L1 & EXTERIOR
LIGHTING CONTROL
L1- 2
L1- 2
L1- 2
L1- 2
L1- 2
L1- 2
L1- 2
L1- 2
L1- 2
L1- 2
E7
E7
E7
E7
E7
E7
E6
E6
E6
E6
PROVIDE #10AWG
IN EX 1"C.
PROVIDE #8AWG IN EX 1"C.
L1- 4 L1- 4 L1- 4 L1- 4
#10AWG IN 1"C.
E5 L1- 4
E5
L1- 4
E5 L1- 4
EX 12"X12" BOX
PROVIDE #10AWG IN 1"C.
PROVIDE #10AWG
IN EX 1"C. (TYP)
EXISTING FLAG POLE
AND LIGHTS
EX C.O. FROM
PHASE 1
NEW
EX EX
ALL PAVILION LTG (TYPE E9)
ON CIRCUIT L1- 6
E9E9
E9E9E9
E9E9E9E9E9
E9E9E9E9
PAVILION
KEY NOTES:
GENERAL NOTES:
A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE
WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF
DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS
PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.
B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS,
WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN
THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF
HOLES TO THE SATISFACTION OF THE CONTRACTING OFFICER.
C. THE TEL/DATA DESIGN INTENT: ELECTRICAL CONTRACTOR PROVIDES BOX AND
CONDUIT TO ACCESSIBLE CEILING. CABLING CONTRACTOR SHALL PULL CABLING
FROM WORK AREA OUTLET (WAO) BACK TO THE I.T. ROOM IN BASEMENT IN OPEN
RACEWAY (UTILIZE D-RINGS AND J-HOOKS). 2 DATA, 1 PHONE, CAT6 TO EACH
WAO. POWERED FURNITURE TO GET 3 DATA, 1 PHONE, CAT6. COIL IN THE I.T.
ROOM AS SPECIFIED. DO NOT ALLOW COILS TO SIT ON THE FLOOR. PULL AND
TERMINATE FIBER BETWEEN EACH BUILDING. TEST ALL CAT6 AND FIBER AS
SPECIFIED. INSTALL RACKS AS SPECIFIED. ALL PATCH PANELS AND OTHER
SERVER EQUIPMENT IS BY CONTRACTING OFFICER. TEL/DATA OUTLETS IN THE
FURNITURE; HOMERUN CABLING THROUGH FURNITURE RACEWAY TO NEAREST
TELECOMMUNICATION ROOM. ROUTE POWER THROUGH THE BOTTOM CHANNEL.
TEL/DATA CABLING SHALL BE ROUTED THROUGH THE TOP CHANNEL.
D. SOUND MASKING/PAGING/MUSIC ZONE PROGRAMMING DESCRIPTION: "a" = SOUND MASKING, INTERCOM & MUSIC, "b" = MUSIC & INTERCOM ONLY, "c" = INTERCOM
ONLY. S1 SPEAKER ARE TO BE MOUNTED IN CEILING. S2 SPEAKERS ARE TO BE
SUSPENDED ABOVE CEILING IN OPEN OFFICE AREAS.
E. ELECTRICAL CONTRACTOR SHALL PROVIDE COMPLETE WIRED SYSTEMS FOR
ALL SECURITY ITEMS AND SPEAKERS. COORDINATE WITH CONTRACTING
OFFICER AND MANUFACTURERS FOR ALL REQUIREMENTS.
- SOUND MASKING/INTERCOM (SEE DETAIL 9 ON SHEET E9.5)
- ACCESS CONTROL TIED INTO INTRUSION SYSTEM WITH CLASS BREAK
DETECTION AND DOOR CONTACTS (SEE SHEET E9.3)
- CAMERA SYSTEM (SEE SHEET E9.3)
F. PROVIDE CLEAR PLASTIC COVERS FOR ALL FIRE ALARM MANUAL PULL
STATIONS.
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:3 :5
P
M
E1.1
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
ELECTRICAL SITE PLAN
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
RJH
BMM
ACB
: 1" = 30'-0"E1.1E1.1
9 PHASE 3 - ELECTRICAL SITE PLAN
1. EXISTING 24"X36" PULL BOXES CONTAIN: (1) 1"C.O. FIRE ALARM, (2) 2"C.O. FIBER,
(1) 2"C.O. COPPER, (3) 3-1/2"C.O. ELECTRICAL SERVICE, (3) 3-1/2"C.O. SPARE. SEE
TRENCH DETAIL ON SHEET E9.1. IN POWER 24"X36" BOX. STUB ELECTRICAL
SERVICE AND (2) SPARES FROM THIS LOCATION TO OFFICE ELECTRICAL SERVICE
DISCONNECT ON LOWER LEVEL. IN TEL/COMM 24X36" BOX. STUB ALL
SIGNALING,CONTROLLING, SECURITY, AND (1) SPARE FROM THIS LOCATION TO
TEL/COMM 002 ON LOWER LEVEL.
2. PROVIDE #8AWG IN 1"C. FOR PARKING/DRIVE AREA LIGHTING. PROVIDE #10AWG
IN 1"C. IN SAME TRENCH TO PROVIDE POWER LIGHTING IN PAVILION.
3. MOUNT PAVILION LIGHTING TO BOTTOM OF SOFFIT AND CENTERED BETWEEN
RAFTERS.
4. PROVIDE CABLE IN CONDUITS TO NEW BUILDING PER ONE-LINE DIAGRAM ON
SHEET E9.1. PROVIDE 24-PAIR, SINGLE MODE FIBER FROM RACK BACK TO
WAREHOUSE SERVER ROOM. UTILIZE CONDUITS SHOWN BETWEEN BUILDINGS.
IN SECOND COMMUNICATIONS CONDUIT PROVIDE 50 PAIR COPPER BETWEEN
BUILDINGS. SEE FIBER DETAIL 11 ON SHEET E9.4 FOR COMMUNICATIONS
CABLING.
5. ALL LIGHT POLE BASES AND CONDUIT IN PARKING LOT ARE EXISTING FROM
PHASE 1. PROVIDE POLE, LUMINAIRE, AND CONDUCTORS.
NORTH
R
O
FE
SS IONAL ENG INEE
RL
I C E N S ED
S T
A
T E O F I D
A H
O
A R
I AN
C . B LOOMF
I E L
D
A B
C
UP
M
M J
J
J
J
M
J
J
J
J F.S.D.
RELAY
F.S.D.
RELAY
F.S.D.
RELAY
C
MECHANICAL
ROOM
ELEV.
FOYER
STORAGE
BUILDING
STORAGE
MDP
M1
C1
MDR
GFIGFI SUMP PUMP
OWNER METER
TEL/COMM
R1A- 6 C1- 3
R1A- 4
R1A- 12
R1A- 6
R1A- 4
C1- 3 R1A- 4
C1- 1
C1- 1
R1A- 4
C1- 17C1- 13C1- 9 C1- 7
C1- 11 C1- 15
L1- 1 M1- 1
BUSSMAN
SHUNT TRIP
M2
M1- 32
EF-1
ELEVATOR CAR LIGHT
BREAKERS
C1- 5
C1- 5
DESK LOCATION
CAMERA DVR IN RACK
GFI
CR POWER
C1- 1
CR
POWER
R1A- 8
R1A- 58
R1A- 60
M1- 24,26,28
DWH1
R1A- 54
R1A- 56
SECURITY
PANEL
INTRUSION
PANEL
M1- 36
FSD
M1- 36
FSD
M1- 36
FSD
GFI
GFI
R1A- 8
GFI
R1A- 8
GFI
STUB (2) 1" C.O. TO EXTERIOR
FOR FUTURE IRRIGATION
BAS PANEL
KEY NOTES:
GENERAL NOTES:
A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE
WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF
DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS
PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.
B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS,
WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN
THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF
HOLES TO THE SATISFACTION OF THE CONTRACTING OFFICER.
C. THE TEL/DATA DESIGN INTENT: ELECTRICAL CONTRACTOR PROVIDES BOX AND
CONDUIT TO ACCESSIBLE CEILING. CABLING CONTRACTOR SHALL PULL CABLING
FROM WORK AREA OUTLET (WAO) BACK TO THE I.T. ROOM IN BASEMENT IN OPEN
RACEWAY (UTILIZE D-RINGS AND J-HOOKS). 2 DATA, 1 PHONE, CAT6 TO EACH
WAO. POWERED FURNITURE TO GET 3 DATA, 1 PHONE, CAT6. COIL IN THE I.T.
ROOM AS SPECIFIED. DO NOT ALLOW COILS TO SIT ON THE FLOOR. PULL AND
TERMINATE FIBER BETWEEN EACH BUILDING. TEST ALL CAT6 AND FIBER AS
SPECIFIED. INSTALL RACKS AS SPECIFIED. ALL PATCH PANELS AND OTHER
SERVER EQUIPMENT IS BY CONTRACTING OFFICER. TEL/DATA OUTLETS IN THE
FURNITURE; HOMERUN CABLING THROUGH FURNITURE RACEWAY TO NEAREST
TELECOMMUNICATION ROOM. ROUTE POWER THROUGH THE BOTTOM CHANNEL.
TEL/DATA CABLING SHALL BE ROUTED THROUGH THE TOP CHANNEL.
D. SOUND MASKING/PAGING/MUSIC ZONE PROGRAMMING DESCRIPTION: "a" = SOUND MASKING, INTERCOM & MUSIC, "b" = MUSIC & INTERCOM ONLY, "c" = INTERCOM
ONLY. S1 SPEAKER ARE TO BE MOUNTED IN CEILING. S2 SPEAKERS ARE TO BE
SUSPENDED ABOVE CEILING IN OPEN OFFICE AREAS.
E. ELECTRICAL CONTRACTOR SHALL PROVIDE COMPLETE WIRED SYSTEMS FOR
ALL SECURITY ITEMS AND SPEAKERS. COORDINATE WITH CONTRACTING
OFFICER AND MANUFACTURERS FOR ALL REQUIREMENTS.
- SOUND MASKING/INTERCOM (SEE DETAIL 9 ON SHEET E9.5)
- ACCESS CONTROL TIED INTO INTRUSION SYSTEM WITH CLASS BREAK
DETECTION AND DOOR CONTACTS (SEE SHEET E9.3)
- CAMERA SYSTEM (SEE SHEET E9.3)
F. PROVIDE CLEAR PLASTIC COVERS FOR ALL FIRE ALARM MANUAL PULL
STATIONS.
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:3 :5
P
M
E2.0
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
LOWER LEVEL POWER PLAN
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
RJH
BMM
ACB
: 1/8" = 1'-0"E2.0E2.0
6 PHASE 3 - LOWER LEVEL POWER PLAN
1. SERVER RACK RECEPTACLES: PROVIDE (2) TYPE 5-20R
DEDICATED RECEPTACLE WITH ISOLATED GROUND, MOUNTED TO
LADDER TRAY ABOVE EACH SERVER RACK. COORDINATE EXACT
SERVER RACK LOCATION WITH CONTRACTING OFFICER, PRIOR
TO ROUGH-IN. (TYPICAL FOR ALL SERVER RACKS)
2. PROVIDE 8FT TALL BY 16FT LONG PAINTED PLYWOOD TTB.
3. VERIFY EXACT LOCATION WITH CONTROLS CONTRACTOR.
R
O
FE
SS IONAL ENG INEE
RL
I C E N S ED
S T
A
T E O F I D
A H
O
A R
I AN
C . B LOOMF
I E L
D
UP
A B
C
R E
F
UP
DN
PF
PF
M
M
M
M
M
M
M
M
M
M
M
M
M M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
J
J
J
J
J
J
JJJ
JJJ
J
M
J
M
J
M
J
M
J
M
J
M
J
M J
M
J
M
J
M
J
M
J
M
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J J
J
M
SD
D
SD
D
J J
J F.S.D.
RELAY
F.S.D.
RELAY
F.S.D.
RELAY
J
S
S
TV
TV
LARGE
MEETIN…
This is the start of the file's text. The full file is on GovTribe.