Drawings_Part_12_2018_06-01.pdf

PDF 4 MB Posted

Attached to
INRC - Phase III
Solicitation number
12034318R0017
Issued by

About this file

This is a pre-solicitation notice for construction of Phase III of the Interagency Natural Resource Center in Coeur d'Alene, Idaho. The project includes a 29,000 square foot main office building to support 173 employees from the U.S. Fish & Wildlife Service, Bureau of Land Management, and U.S. Forest Service. The project magnitude is estimated between $5 million and $10 million. The solicitation for proposals is expected to be posted on or around June 5, 2018 with responses due 30 days after posting. The project will be awarded by the Northern Region of the U.S. Forest Service.

22 - J-3 Drawings Part 12

View the file

Other files

File Type Posted
INRC_First_Floor.dwg DWG drawing
7-12-18_Q&A.XLSX XLSX spreadsheet
INRC_Second_Floor.dwg DWG drawing
Amendment_0002.pdf PDF
Revised_B-1.pdf PDF
Questions_and_Answers_062918.pdf PDF
125900_SF_-_SYSTEMS_FURNITURE.pdf PDF
S0.1_(rev1).pdf PDF
C1.3_(rev1).PDF PDF
Amendment_0001.pdf PDF
CV_(rev1).pdf PDF
L1.5_(rev1).pdf PDF
Prebid_Notes_6-19-18.pdf PDF
Prebid_Attendance.pdf PDF
Questions_and_Answers_061818.pdf PDF
J-5_Past_Performance_Questionnaire.pdf PDF
Part_4_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_4_2018_06-01.pdf PDF
Drawings_Part_5_2018_06-01.pdf PDF
Drawings_Part_2_2018_06-01.pdf PDF
Drawings_Part_11_2018_06-01.pdf PDF
Short_Set_Solicitation_12034318R0017_Final_06072018.pdf PDF
J-4_State_of_Idaho_Workers'_Insurance.pdf PDF
Part_3_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_7_2018_06-01.pdf PDF
Solicitation_12034318R0017_Final_06072018.pdf PDF
Part_7_Project_Manual_2018_06_01.pdf PDF
Part_1_Project_Manual_2018_06_01.pdf PDF
Part_5_Project_Manual_2018_06_01.pdf PDF
Part_6_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_8_2018_06-01.pdf PDF
J-1_Wage_Rate_Decision_ID180031_Mod_3_Dated_05112018.pdf PDF
Drawings_Part_10_2018_06-01.pdf PDF
Drawings_Part_14_2018_06-01.pdf PDF
Part_2_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_1_2018_06-01.pdf PDF
Drawings_Part_13_2018_06-01.pdf PDF
Drawings_Part_6_2018_06-01.pdf PDF
Drawings_Part_9_2018_06-01.pdf PDF
Drawings_Part_3_2018_06-01.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HP-2

REYQ360TTJU

REYQ120TTJU REYQ120TTJU REYQ120TTJU

½"×1⅛"×¾" ½"×1⅛"×¾" ⅝"x1⅜"x1⅛"

½"×1⅛"×¾"

BHFP26P151U

160.0ft [8]

KHRP25M73TU9

⅞"×1⅝"×1⅜" * 5.0ft

KHRP25M73TU9

⅝"×1⅛"×1⅛"

BS-25

BSQ36TVJ

5.0ft ⅜"×⅝"×½"

FC-234

FXMQ36PBVJU

10.0ft [2] ⅜"×⅝"

15.0ft

KHRP25M73TU9

⅝"×1⅛"×1⅛" 15.0ft

KHRP25A33T9

⅜"×⅞"×¾"

BS-26

BSQ60TVJ

3.0ft ⅜"×⅝"×½"

FC-237

FXMQ48PBVJU

5.0ft [2] ⅜"×⅝"

BS-14

BSQ36TVJ

10.0ft ⅜"×⅝"×½"

FC-202

FXMQ24PBVJU

15.0ft [2] ⅜"×⅝"

20.0ft

KHRP25A33T9

⅜"×⅞"×¾"

BS-17

BSQ36TVJ

5.0ft ⅜"×⅝"×½"

FC-214

FXMQ30PBVJU

5.0ft [2] ⅜"×⅝"

25.0ft

KHRP25A22T9

⅜"×¾"×⅝"

BS-16

BSQ36TVJ

5.0ft ⅜"×⅝"×½"

FC-205

FXMQ30PBVJU

5.0ft [2] ⅜"×⅝"

10.0ft

KHRP25A22T9

⅜"×⅝"×½"

BS-15

BSQ36TVJ

5.0ft ⅜"×⅝"×½"

FC-204

FXMQ15PBVJU

5.0ft [2] ¼"×½" *

BS-13

BSQ36TVJ

10.0ft ⅜"×⅝"×½"

FC-201

FXFQ24TVJU

10.0ft [2] ⅜"×⅝"

25.0ft [2]

KHRP25M73TU9

⅝"×1⅛"×1⅛"

BS-20

BSQ36TVJ

15.0ft ⅜"×⅝"×½"

FC-225

FXFQ18TVJU

10.0ft [2] ¼"×½" *

10.0ft

KHRP25M73TU9

⅝"×1⅛"×1⅛"

BS-24

BSQ60TVJ

15.0ft ⅜"×⅝"×½"

3.0ft

KHRP26A22T9

⅜"×⅝"

FC-231

FXMQ30PBVJU

15.0ft [2] ⅜"×⅝"

FC-232

FXZQ15MVJU9

15.0ft [2] ¼"×½"

10.0ft

KHRP25M72TU9

½"×1⅛"×¾"

BS-21

BSQ36TVJ

15.0ft ⅜"×⅝"×½"

FC-226

FXMQ18PBVJU

5.0ft [2] ¼"×½" *

15.0ft

KHRP25M72TU9

½"×1⅛"×¾"

BS-19

BSQ36TVJ

3.0ft ⅜"×⅝"×½"

FC-224

FXZQ12MVJU9

5.0ft [2] ¼"×½" *

5.0ft

KHRP25M72TU9

½"×1⅛"×¾"

BS-18

BSQ36TVJ

3.0ft ⅜"×⅝"×½"

FC-216

FXMQ15PBVJU

5.0ft [2] ¼"×½" *

5.0ft

KHRP25A33T9

⅜"×⅞"×¾"

BS-22

BSQ60TVJ

15.0ft ⅜"×⅝"×½"

FC-228

FXMQ48PBVJU

10.0ft [2] ⅜"×⅝"

BS-23

BSQ60TVJ

20.0ft [2] ⅜"×¾"×⅝" *

FC-230

FXMQ54PBVJU

5.0ft [2] ⅜"×⅝"

HP-1

REYQ384TTJU

REYQ168TTJU REYQ120TTJU REYQ96TTJU

⅝"×1⅛"×⅞" ½"×1⅛"×¾" ⅝"x1⅜"x1⅛"

⅜"×⅞"×¾"

BHFP26P151U

80.0ft [6]

KHRP25M73TU9

¾"×1⅝"×1⅜" 35.0ft [2]

KHRP25M73TU9

⅝"×1⅛"×1⅛" 15.0ft

KHRP25M72TU9

½"×1⅛"×¾" 5.0ft

KHRP25A33T9

⅜"×⅞"×¾" 10.0ft

KHRP25A33T9

⅜"×⅞"×¾"

BS-2

BSQ36TVJ

5.0ft [1] ⅜"×⅝"×½"

FC-123

FXMQ24PBVJU

25.0ft [2] ⅜"×⅝"

BS-1

BSQ60TVJ

15.0ft ⅜"×⅝"×½"

FC-131

FXMQ48PBVJU

25.0ft [4] ⅜"×⅝"

BS-11

BSQ36TVJ

15.0ft ⅜"×⅝"×½"

FC-136

FXMQ30PBVJU

5.0ft [2] ⅜"×⅝"

BS-3

BSQ60TVJ

15.0ft [2] ⅜"×⅝"×½"

5.0ft

KHRP26A22T9

⅜"×⅝"

FC-122a

FXMQ30PBVJU

25.0ft [4] ⅜"×⅝"

FC-122b

FXMQ15PBVJU

20.0ft [3] ¼"×½"

BS-4

BSQ36TVJ

10.0ft ⅜"×⅝"×½"

3.0ft

KHRP26A22T9

⅜"×⅝"

FC-127

FXMQ07PBVJU

25.0ft [3] ¼"×½"

FC-117

FXMQ18PBVJU

25.0ft [3] ¼"×½"

5.0ft

KHRP25M73TU9

¾"×1⅜"×1⅛"

BS-5

BSQ36TVJ

5.0ft ⅜"×⅝"×½"

FC-114

FXZQ15MVJU9

10.0ft [2] ¼"×½" *

3.0ft

KHRP25M73TU9

¾"×1⅜"×1⅛"

BS-6

BSQ60TVJ

3.0ft ⅜"×⅝"×½"

10.0ft

KHRP26A22T9

⅜"×⅝"

FC-137

FXZQ18MVJU9

10.0ft [3] ¼"×½"

FC-139

FXMQ30PBVJU

15.0ft [2] ⅜"×⅝"

20.0ft

KHRP25M73TU9

¾"×1⅜"×1⅛"

BS-7

BSQ60TVJ

30.0ft ⅜"×¾"×⅝" *

FC-143

FXMQ54PBVJU

5.0ft [2] ⅜"×⅝"

30.0ft

KHRP25M73TU9

⅝"×1⅛"×1⅛"

BS-9

BSQ36TVJ

5.0ft ⅜"×⅝"×½"

FC-103

FXMQ24PBVJU

15.0ft [3] ⅜"×⅝"

15.0ft

KHRP25M72TU9

½"×1⅛"×¾"

BS-10

BSQ36TVJ

5.0ft ⅜"×⅝"×½"

FC-104

FXMQ12PBVJU

5.0ft [2] ¼"×½" *

10.0ft

KHRP25M72TU9

½"×1⅛"×¾"

BS-12

BSQ96TVJ

5.0ft ⅜"×⅞"×¾"

FC-105b

FXMQ72MVJU

20.0ft [2] ⅜"×¾" *

BS-8

BSQ96TVJ

5.0ft ⅜"×⅞"×¾"

FC-105a

FXMQ72MVJU

15.0ft [2] ⅜"×¾" *

VARIABLE REFRIGERANT (VRF) SYSTEM SCHEMATIC: SYSTEM #1 & #2

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:0 :2

P

M

M9.2

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

REFRIGERANT PIPING SCHEMATICS

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

BJK/JTW

TJB

JTW

P

R E E

NI

GN

ELANOISSEF

O R R

EG

ISTERE

D

S

T A

TE OF ID

AH

O

WAVERE

K

TYD

O J

11076

PIPE SCHEDULE

SYSTEM PIPE MATERIAL SIZE

INSULATION

THICKNESS REMARKS

DOM. COLD WATER - ABOVE GRADE TYPE L COPPER ALL 1/2" PRO-PRESS OR SWEAT

DOM. COLD WATER - MAIN SUPPLY

TYPE L COPPER OR

AQUATHERM (GREEN) ALL 1/2"

PRO-PRESS OR SWEAT, OR

HEAT FUSION (AQUATHERM)

DOM. HOT WATER - ABOVE GRADE TYPE L COPPER ALL 1" PRO-PRESS OR SWEAT

DOM. HOT WATER - MAIN SUPPLY

TYPE L COPPER OR

AQUATHERM (GREEN) ALL 1"

PRO-PRESS OR SWEAT, OR

HEAT FUSION (AQUATHERM)

WASTE PVC ALL NONE NEW SANITARY WASTE

VENT PVC ALL NONE NEW VENT PIPING

NATURAL GAS PIPING STEEL ALL NONE - -

NOTE:

1. INSULATION THICKNESS IS BASED ON A CONDUCTIVITY NOT EXCEEDING .27 BTU PER INCH/H * FT^2 * °F

2. PLASTIC PIPE SHALL NOT BE INSTALL WITHIN THE FIRST 18" OF A WATER HEATER.

OUTSIDE DIAMETER OF PIPE

OR COVERING LENGTH OF COLOR FIELD A SIZE OF LETTERS B

INCHES MM INCHES MM INCHES MM

3/4" TO 1-1/4" 19 TO 32 8" 200 1/2" 13

1-1/2" TO 2" 38 TI 51 8" 200 3/4" 19

2-1/2" TO 6" 64 TO 150 12" 300 1-1/4" 32

8" TO 10" 200 TO 250 24" 600 2-1/2" 64

OVER 10" OVER 250 32" 800 3-1/2" 89

SERVICE BACKGROUND LETTER COLOR

DOMESTIC COLD WATER GREEN WHITE

DOMESTIC HOT WATER YELLOW BLACK

DOMESTIC HOT WATER RETURN YELLOW BLACK

FIRE PROTECTION (SPRINKLER) RED WHITE

FUEL GAS YELLOW BLACK

SANITARY DRAIN GREEN WHITE

PLUMBING FIXTURE SCHEDULE

MARK DESCRIPTION MANUF MODEL NUMBER

MOUNTING /

MOUNTING

HEIGHT

MATERIAL & FINISH TRIM

SIZE AT FINAL CONNECTION TO FIXTURE

REMARKS

DRAIN VENT COLD HOT

BP1 BACKFLOW PREVENTER - REDUCED PRESS ZONE-LEAD FREE WATTS LF009-QT-S PIPE BRONZE BODY - LEAD FREE

SHUT-OFF VALVES, STRAINER, AIR

GAP LINE SIZE - - LINE SIZE - - REDUCED PRESSURE ZONE BACKFLOW PREVENTER WITH SHUT-OFF VALVES, STRAINER, AND AIR GAP FITTING - DRAIN TO NEAREST FLOOR DRAIN

BV BALL VALVE - TWO PIECE - FULL PORT - LEAD FREE WATTS LFB6081G2 PIPE BRONZE CONSTRUCTION - LEAD FREE SOLDER ENDS - - - - LINE SIZE LINE SIZE BRONZE BALL VALVE - TWO PIECE - FULL PORT - 600 PSIG WOG - BLOW-OUT PROOF STEM

CV CHECK VALVE - WYE PATTERN WATTS LFWCVS PIPE BRASS CONSTRUCTION - LEAD FREE BRONZE DISK - - - - LINE SIZE LINE SIZE WYE PATTERN BRONZE CHECK VALVE - 200 PSIG WOG

ET1 EXPANSION TANK - SMALL ASME RATED AMTROL ST-12 PIPE STEEL - BUTYL DIAPHRAGM - ANTIMICROBIAL WITH CHARGING VALVE - - - - - - 3 / 4" THERMAL EXPANSION ABSORBER - ANTI MICROBIAL LINER - 4.4 GALLON TOTAL VOLUME - 3.2 GALLON ACCEPTANCE VOLUME

EWC1 ELECTRIC WATER COOLER - DUAL HEIGHT - BOTTLE FILLER HALSEY TAYLOR HTHB-HACG8BLSS-NF

WALL / UPPER

ORIFICE 39.5" -

LOWER 33"

STAINLESS STEEL - LEAD FREE WITH BOTTLE FILLER 2" 1 - 1 / 2" 1 / 2" - - 1.1 GPM BOTTLE FILL RATE - BI-LEVEL UNIT - 8.0 GALLONS PER HOUR - 120 VOLT - EASY FLEX BUBBLER - PROVIDE P-TRAP AND WATER SERVICE STOP -

BRASSCRAFT #KTCR STOP

FCO FLOOR CLEAN OUT JR SMITH 4021S FLOOR

CAST IRON BODY / BRONZE PLUG / NICKEL

BRONZE TOP

TWIST ADJUSTMENT - CARPET

CLAMP WHERE REQUIRED 2" - 4" SEE PLANS - - - - - - PROVIDE WITH CARPET CLAMP AT CARPET AREAS

FD1 FLOOR DRAIN WITH ADJUSTABLE HEIGHT ROUND STRAINER JR SMITH 2005 FLOOR CAST IRON BODY / NICKEL BRONZE STRAINER TRAP PRIMER CONNECTION 2" - 4" SEE PLANS 1-1/2"-2"SEE PLANS - - - - PROVIDE COMPLETE WITH PRO SEAL "TRAP GUARD" TRAP SEAL PRIMER

IM1 PLASTIC ICE MAKER BOX LSP OB-801 WALL / VARIES BRASS CONSTRUCTION - WETTED AREAS WITH MIP VALVE - - - - 1 / 2" 1 / 2" PLASTIC BOX WITH MIP BALL VALVE - MOUNT ABOVE COUNTER BACKSPLASH

L1 LAVATORY - COUNTERTOP - TOUCHLESS FAUCET KOHLER K-2210 UNDER-COUNTER VITREOUS CHINA W/ MOEN #8554 FAUCET-GRID DRAIN 2" 1 - 1 / 2" 1 / 2" 1 / 2" WITH ELECTRONIC FAUCET & BRASSCRAFT #KTCR QUARTER TURN STOPS

LHCO LAMP HOLE CLEAN OUT JR SMITH 4261L GRADE CAST IRON BODY / HEAVY DUTY COVER SPEEDI - SET NO-HUB FITTING 4" - - - - - - FINISH AT GRADE

MV1 MIXING VALVE - SINGLE SYMMONS 7-500 - B SERIES WALL / 48" BRONZE AND STAINLESS STEEL - LEAD FREE WITH 3" DIA THERMOMETER - - - - 1" 1' 1 - 1 / 4" OUTLET - 0.5 GPM MINIMUM - 50 GPM MAXIMUM (20 PSI DROP) - PROVIDE CABINET, CHECK STOPS, REMOVABLE CARTRIDGE, VACUUM BREAKER, &

STRAINER

PG PRESSURE GAUGE ERNST TL35P PIPE STEEL CASE - BRONZE TUBE BRASS MOVEMENT - - - - - - - - ACCURACY = 2% OF MIDDLE OF RANGE - USE PRESSURE RANGE SO THAT NEEDLE IS IN MIDRANGE DURING NORMAL OPERATION

PRV PRESSURE REDUCING VALVE - STANDARD WITH BYPASS WATTS LFU5B-Z3 PIPE BRONZE - STAINLESS STEEL SEAT - LEAD FREE WITH STRAINER & BYPASS - - - - LINE SIZE - - 1" UNIT RATED AT 30 GPM AT 15 PSI PRESSURE DROP - MAXIMUM WORKING PRESSURE IS 300 PSI - REDUCED PRESSURE RANGE IS 25 - 75 PSI (ADJUSTABLE)

RCP1 RE-CIRCULATION PLUMBING PUMP TACO 006-B4-2PNP PIPE BRONZE OR STAINLESS STEEL WITH DIGITAL TIMER & AQUASTAT - - - - - - 3 /4" 6 GPM AT 7 FT HEAD - WITH DIGITAL TIMER AND AQUASTAT - PUMP ON 95F, PUMP OFF 115F - 115 VOLT - 1 / 40 HP - CORD & PLUG ELECTRICAL CONNECTION

S1 SINK - DOUBLE COMPARTMENT - PULL OUT FAUCET JUST DL-2133-A-GR COUNTER STAINLESS STEEL MOEN #7560 FAUCET WITH PULL-OUT SPRAY 2" 1 - 1 / 2" 1 / 2" 1 / 2" PROVIDE BRASSCRAFT #KT STOPS - VERIFY DIMENSIONS WITH DRAWINGS PRIOR TO ORDERING - VERIFY HOLE PUNCH REQUIREMENTS - 8" DEEP -

BRASSCRAFT #KTCR STOP

SS1 SERVICE SINK - FLOOR MOUNTED 24" x 24" FIAT MSB 2424 FLOOR MOLDED STONE CONSTRUCTION WITH MOEN #8124 FAUCET 4" 2" 1 / 2" 1 / 2" WITH #832-AA HOSE & HOSE BRACKET, #889-CC MOP HANGER, #E-88-AA STAINLESS STEEL BUMPER GUARD, AND #MSG2424 STAINLESS STEEL WALL GUARD

T1 THERMOMETER - DIAL TYPE - 3" DIAL TRERICE B836 PIPE STAINLESS STEEL ADJUSTABLE ANGLE - - - - - - - - STEM TO CENTER OF PIPE - 3 INCH CASE - 0F TO 100F RANGE FOR COLD WATER - 0F TO 200F RANGE FOR HOT WATER

TP TRAP PRIMER - DIFFERENTIAL PRESSURE WATTS LFTP300 PIPE BRASS - LEAD FREE - EPDM SEALS 695-Y52 SPLITTER IF REQUIRED 1 / 2" - - - - - - DIFFERENTIAL PRESSURE TYPE - ACTIVATES ON 10 PSIG DROP IN PRESSURE - MIN / MAX WORKING PRESSURE IS 30 / 250 PSIG - RUN TUBING TO FLOOR

DRAIN - PROVIDE ACCESS BOX IN WALL

UR URINAL - TOP SPUD - TOUCHLESS - STANDARD HEIGHT KOHLER K-4904-ET WALL / LIP 24" VITREOUS CHINA MOEN #8316 FLUSH VALVE 2" 1 - 1 /2" 3 / 4" - - VITREOUS CHINA 1 / 8 GALLON PER FLUSH URINAL WITH TOP SPUD - STANDARD HEIGHT MOUNTING - BATTERY OPERATED FLUSH VALVE

WCO WALL CLEAN OUT JR SMITH 4432 WALL / 18" STEEL WITH CHROME COVER LINE SIZE - - - - - - CAST IRON CAULK FERULE WITH CASE IRON LEAD SEAL PLUG

WC1 WATER CLOSET - WALL MNTD - ELECT FLUSH - STANDARD HT KOHLER K-4325 WALL / RIM 15" VITREOUS CHINA MOEN #8310DF16 FLUSH VALVE 4" 2" 1" - - PROVIDE JR SMITH #0300 SERIES CARRIER - BATTERY POWERED FLUSH VALVE - (1.0 GALLONS PER FLUSH WHEN LESS THAN 60 SECONDS - 1.6 GALLONS PER FLUSH WHEN LONGER THAN 60 SECONDS) KOHLER #K-4667-C EXTRA HEAVY DUTY ELONGATED OPEN FRONT SEAT

WC2 WATER CLOSET - WALL MNTD - ELECT FLUSH - ADA HEIGHT KOHLER K-4325 WALL / RIM 17" VITREOUS CHINA MOEN #8310DF16 FLUSH VALVE 4" 2" 1" - - PROVIDE JR SMITH #0300 SERIES CARRIER - BATTERY POWERED FLUSH VALVE - (1.0 GALLONS PER FLUSH WHEN LESS THAN 60 SECONDS - 1.6 GALLONS PER FLUSH WHEN LONGER THAN 60 SECONDS) KOHLER #K-4667-C EXTRA HEAVY DUTY ELONGATED OPEN FRONT SEAT

WH1 WALL HYDRANT - NON-FREEZE WOODFORD MODEL 67 WALL / 18" CHROME PLATED FINISH - - - - - - 3 / 4" - - 12" LENGTH OR AS REQUIRED FOR WALL THICKNESS

WHA WATER HAMMER ARRESTOR SIOUX CHIEF 656-E PIPE COPPER - - - - - - 1' 1' MAX WORKING TEMPERATURE 250F - MAX WORKING PRESSURE 350PSIG - 115 TO 155 FIXTURE UNIT VALUE

NOTES: PROVIDE ALL FIXTURES WITH APPROPRIATE COMMERCIAL GRADE SUPPORTS/CARRIERS, P-TRAPS, STOP VALVES, COMMERCIAL GRADE BRAIDED STAINLESS STEEL FLEXIBLE SUPPLIES, UNDER FIXTURE PIPING INSULATION AND WATER HAMMER ARRESTORS. PROVIDE AND INSTALL TRAP PRIMERS FOR ALL FLOOR DRAINS AND FLOOR SINKS UNLESS OTHERWISE INDICATED. INSTALL ALL TRAP PRIMERS IN RECESSED WALL MOUNTED BOXES IN AN ACCESSIBLE LOCATION. FIELD COORDINATE INSTALLATION LOCATION WITH ARCHITECT/ENGINEER. FIELD COORDINATE LOCATION AND NUMBER OF FAUCET MOUNTING HOLES WITH GENERAL CONTRACTOR. INSTALL ALL FIXTURES AS PER THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS.

DOMESTIC COLD WATER (DCW)

DOMESTIC HOT WATER (DHW)

DOMESTIC HOT WATER RECIRC (DHWR)

SANITARY SEWER (SAN)

VENT (V)

FIRE (F)

NATURAL GAS (G)

PLUMBING SYSTEMS LEGEND

PIPE LABEL SCHEDULE

DOMESTIC WATER HEATER SCHEDULE

MARK MFR MODEL

NUMBER

STORAGE

(GAL.)

HEAT

SOURCE

TOTAL

INPUT

(kW)

IMMERSION HEATERS

NO. OF 50A

CONTACTORS TYPE MOUNTING

UNIT PHYSICAL INFORMATION

ADDITIONAL DETAILS

QUANTITY kW HEIGHT DIA.

SHIPPING

WEIGHT (LBS)

DWH1 A.O. SMITH DSE-30 30 ELECTRIC 18 1 18 1 COMMERCIAL 4" CONC PAD 35-3/4" 20-1/2" 150 SEE BELOW

REMARKS:

1. HEAVY DUTY COMERCIAL CONSTRUCTION, 125 PSI WORK PRESS. STANDARD

2. INSULATION: ENTIRE TANK IS SURROUNDED WITH HIGH DENSITY FIBERGLASS

INSULATION, (R12.5) ASHRAE 90.1

3. CABINET: HEAVY GAUGE STEEL WITH HIGH QUALITY POWDER COAT PAINT

4. INTERNALLY GLASS-LINED

5. PRECISE ELECTRONIC CONTROL W/ DIGITAL DISPLAY.

6. ELEMENT SENSING: MONITORED AND DISPLAYED ON SCREEN, ON/OFF, FAILURE.

7. ALL PIPING WITHIN 18" OF WATER HEATER SHALL BE COPPER OR STEEL.

8. PROVIDE ASME TEMPERATURE AND PRESSURE RELIEF VALVES. PIPE TO WITHIN 1" OF FLOOR.

9. PROVIDE TEMPERATURE AND PRESSURE GAUGE.

10. PROVIDE SEISMIC BRACING PER SPECIFICATIONS.

11. PROVIDE SHEET METAL PAN WITH 3/4" SCHEDULE 40 PVC DRAIN TO NEAREST FLOOR DRAIN.

12. THREE YEAR LIMITED WARRANTY

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:0 :1

P

M

P0.1

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

PLUMBING SCHEDULES AND LEGENDS

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

BJK/JTW

TJB

JTW

P

R E E

NI

GN

ELANOISSEF

O R R

EG

ISTERE

D

S

T A

TE OF ID

AH

O

WAVERE

K

TYD

O J

A B

C

UP

KEY NOTES:

PLUMBING GENERAL NOTES:

1. IT IS NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH

OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS,

CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT THIS

PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.

THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.

3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS

REQUIRED BY LOCAL CODES.

4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH

OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND

ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR

ADDITIONAL DETAILS NECESSARY FOR COORDINATION.

5. ABSOLUTELY NO FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER

THE CONCRETE SLAB.

6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.

7. PROVIDE TRAP PRIMERS AND TRAP SEALS FOR ALL FLOOR DRAINS.

8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL

FIXTURES.

9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS

TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.

10.ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.

A

754321

MECHANICAL

ROOM

BUILDING

STORAGE

ELEV.

FOYER

STORAGE

TEL/COMM

1"ø DCW

DWH1

LHCO

CO

2"DCW

1"DHW

1 2 3 4 5 6 7

D

C

B

4"ø SAN

2"ø SAN

2"ø DCW

4"ø SAN

2"ø DCW

74"ø FP 4"ø FP

1"ø DHW

3/4"DHWR

3/4"ø DHWR

EMR

003A

NOTE:

ALL PIPING SHOWN IS IN

LOWER LEVEL CEILING

BP1

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:0 :1

P

M

P2.0

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

LOWER LEVEL PLUMBING PLAN

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

BJK/JTW

TJB

JTW

: 1/8" = 1'-0"P2.0

9 LOWER LEVEL PLUMBING PLAN

1. VERTICAL PIPE TRANSITION UP, CONTINUED ON PLUMBING PLAN FOR LEVEL

ABOVE. SIZE AND SYSTEM AS NOTED.

2. PROVIDE 1/2" PEX TO FLOOR DRAIN TRAP PRIMER, TYP. ALL FLOOR DRAINS. SEE

DETAIL 9/P9.1.

3. EXTENT OF BASEMENT. PLUMBING BEYOND WILL BE BELOW GRADE AND UNDER

CONCRETE SLAB.

4. REFER TO UNDERFLOOR PLUMBING PLAN P2.1 AT LEVEL ABOVE FOR MORE

INFORMATION REGARDING WASTE AND VENT PIPING.

5. 4" SAN. WASTE THRU CONC. FOUNDATION WALL. PIPE INVERT ELEVATION = 33"

BELOW FINISH FLOOR. FINISH FLOOR ELEVATION = 2255.00'. PIPE INVERT

ELEVATION = 2252.25'. COORDINATE WITH SITE CIVIL CONTRACTOR.

6. 2" DOMESTIC WATER SERVICE LINE THRU CONC. FOUNDATION WALL AT MIN. 6-FT

BELOW FINISHED GRADE ELEVATION.

7. 4" FIRE SPRINKLER WATER SERVICE LINE THRU CONC. FOUNDATION WALL AT

MIN. 6-FT BELOW FINISHED GRADE ELEVATION.

8. RESERVE THIS AREA FOR FIRE SPRINKLER RISER. SHOWN WITH BOLD, DASHED

LINE.

9. 2"CONDENSATE DRAIN, CND FROM FAN COILS CONDENSATE DRAIN LOOP ABOVE.

TIE-IN TO SANITARY SEWER AT SUITABLE LOCATION. REFER TO M2.4 FOR

CONTINUATION. COORDINATE HVAC TRADES.

10.REFER TO DETAIL 1/P9.1 FOR DOMESTIC WATER SERVICE ENTRANCE

REQUIREMENTS.

11.REFER TO DETAIL 2/P9.1 FOR HOT WATER PIPING REQUIREMENTS.

12.ELEVATOR SUMP - SEE DETAIL P9.1.

P

R E E

NI

GN

ELANOISSEF

O R R

EG

ISTERE

D

S

T A

TE OF ID

AH

O

WAVERE

K

TYD

O J

P9.2/P

UP

B

C

R E

F

UP

DN

PF

PF

KEY NOTES:

PLUMBING GENERAL NOTES:

1. IT IS NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH

OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS,

CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT THIS

PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.

THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.

3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS

REQUIRED BY LOCAL CODES.

4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH

OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND

ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR

ADDITIONAL DETAILS NECESSARY FOR COORDINATION.

5. ABSOLUTELY NO FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER

THE CONCRETE SLAB.

6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.

7. PROVIDE TRAP PRIMERS AND TRAP SEALS FOR ALL FLOOR DRAINS.

8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL

FIXTURES.

9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS

TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.

10.ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.

C.O.

FD1FD1

4"ø SAN4"ø SANLHCO

L1

L1L1

L1

EWC1

WC1

WC1WC1

UR

WC2 WC2SS1

S1

L1

L1

WC1

WC2

WC2

MEDIUM

CONFERENCE

ROOM

ENTRY

VEST.

LARGE

MEETING

ROOM

STORAGE

105A

VESTIBULE/

BREAKOUT

FHP

OFFICE

FHP/BLM

STORAGE

FHP

OPEN

OFFICE

MENS

PUBLIC

RESTROOM

WOMENS

PUBLIC

RESTROOM

ELEC.

CLOS.

MENS

RESTROOM

WOMENS

RESTROOM

SMALL

CONFERENCE

ROOM /

LACTATION

PRINT

ROOM

BLM

OPEN

OFFICE

BLM

OFFICE

BLM

OFFICE

BLM

OPEN

OFFICE

ELEV.

STAIR

LOBBY

102 MAIL

ROOM

103A

RECEPTION

MEDIUM

CONFERENCE

ROOM

FMO

OPEN

OFFICE

STAIR

BLM

OFFICE

BLM

OFFICE

BLM

OFFICE

BLM

OFFICE

FMO

OFFICE

CIO

OFFICE

PRIVACY

ROOM

BLM

STG.

JAN.

CLOS.

VESTIBULE

LAW

OFFICE

(USFS)

LAW

OFFICE

(USFS)

LAW

OFFICE

(USFS)

LAW

EVIDENCE

ROOM

LAW

OFFICE

(BLM)

LAW

ENFORCEMENT

OPEN

OFFICE

STORAGE

131A

CORRIDOR

113B

WC1

WC1 UR

L1

L1

4"ø SAN

FD1

FD1

FCO

FCO

4"

SAN.

2 2

1 2 3 4 5 6 7

EWC1

BREAKROOM

L1L1

WCO

FCO

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:0 :1

P

M

P2.1

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

FIRST/GROUND LEVEL UNDERFLOOR

PLUMBING PLAN

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

BJK/JTW

TJB

JTW

: 1/8" = 1'-0"P2.1

9 FIRST/GROUND LEVEL UNDERFLOOR PLUMBING PLAN

1. 4" VERTICAL PIPE TRANSITION UP CONTINUED ON SHEET P2.3.

2. PROVIDE 1/2" PEX TO FLOOR DRAIN TRAP PRIMER, TYP. ALL FLOOR DRAINS. SEE

DETAIL 9/P9.1.

3. 4" SAN. WASTE THRU CONC. FOUNDATION WALL. PIPE INVERT ELEVATION = 33"

BELOW FINISH FLOOR. FINISH FLOOR ELEVATION = 2255.00'. PIPE INVERT

ELEVATION = 2252.25'. COORDINATE WITH SITE CIVIL CONTRACTOR. SEE SHEET

P2.0 FOR ADDITIONAL INFORMATION.

4. NEW GAS METER BY SERVICE PROVIDER. SEE CIVIL FOR CONTINUATION.COORD.

W/ LOCAL UTILITY. GAS DEMAND 400-MBh (7-INWC), PROVIDE PULSE SIGNAL TO

OWNER'S MASTER ELECT. METER

P

R E E

NI

GN

ELANOISSEF

O R R

EG

ISTERE

D

S

T A

TE OF ID

AH

O

WAVERE

K

TYD

O J

B

C

R E

F

UP

DN

PF

PF

KEY NOTES:

PLUMBING GENERAL NOTES:

1. IT IS NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH

OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS,

CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT THIS

PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.

THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.

3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS

REQUIRED BY LOCAL CODES.

4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH

OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND

ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR

ADDITIONAL DETAILS NECESSARY FOR COORDINATION.

5. ABSOLUTELY NO FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER

THE CONCRETE SLAB.

6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.

7. PROVIDE TRAP PRIMERS AND TRAP SEALS FOR ALL FLOOR DRAINS.

8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL

FIXTURES.

9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS

TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.

10.ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.

L1

L1L1

L1

EWC1

WC1

WC1

WC1

UR

WC2 WC2

SS1

MEDIUM

CONFERENCE

ROOM

ENTRY

VEST.

LARGE

MEETING

ROOM

STORAGE

105A

VESTIBULE/

BREAKOUT

FHP

OFFICE

144 FHP/BLM

STORAGE

FHP

OPEN

OFFICE

MENS

PUBLIC

RESTROOM

WOMENS

PUBLIC

RESTROOM

ELEC.

CLOS.

MENS

RESTROOM

WOMENS

RESTROOM

BREAKROOM

SMALL

CONFERENCE

ROOM /

LACTATION

PRINT

ROOM

BLM

OPEN

OFFICE

BLM

OFFICE

BLM

OFFICE

BLM

OPEN

OFFICE

ELEV.

STAIR

LOBBY

MAIL

ROOM

103A

RECEPTION

MEDIUM

CONFERENCE

ROOM

FMO

OPEN

OFFICE

STAIR

BLM

OFFICE

BLM

OFFICE

BLM

OFFICE

BLM

OFFICE

FMO

OFFICE

CIO

OFFICE

PRIVACY

ROOM

BLM

STG.

JAN.

CLOS.

VESTIBULE

LAW

OFFICE

(USFS)

LAW

OFFICE

(USFS)

LAW

OFFICE

(USFS)

LAW

EVIDENCE

ROOM

LAW

OFFICE

(BLM)

LAW

ENFORCEMENT

OPEN

OFFICE

STORAGE

131A

CORRIDOR

113B

WC2

WC2

WC1 WC1

WC1 UR

L1

L1

L1

L1

FD1

FD1

IM1

FD1FD1 1 1/2"ø DCW

1 1/2"ø DCW 3/4"ø DHW

3/4"ø DCW

2-1/2"V

2"DCW

2 1/2"V

S1

6 1"DHW

1 2 3 4 5 6 7

3/4"ø DHW

EWC1

L1L1

3/4"ø DHWR

3/4"DHWR

3/4"ø DHWR

1 1/2"ø DCW

1 1/2"ø DCW

WHA

WHA

WH1

3/4"ø DCW

3/4"ø DCW

WH1

WH1

3/4"ø DCW

BV

BV

BV

WH1

1 1/2"ø V

3/4"ø DCW

1/2"ø DHW 3/4"ø DCW

3/4"ø DHWR

BV

TP

TP 2"ø V

1 1/2"ø DCW

2" ø

V

TYP.

BV

TYP.

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:0 :2

P

M

P2.2

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

FIRST/GROUND LEVEL PLUMBING PLAN

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

BJK/JTW

TJB

JTW

: 1/8" = 1'-0"P2.2

9 FIRST/GROUND LEVEL PLUMBING PLAN

1. VERTICAL PIPE TRANSITION UP, CONTINUED ON PLUMBING PLAN P2.4. SIZE AND

SYSTEM AS NOTED.

2. PROVIDE 1/2" PEX TO FLOOR DRAIN TRAP PRIMER, TYP. ALL FLOOR DRAINS. SEE

DETAIL 9/P9.1.

3. HOT & COLD WATER DOWN IN INTERIOR WALL TO UNDER CABINETRY & OVER TO

COUNTER-MOUNTED SINK.

4. CW PIPING TO REFRIGERATOR ICE-MAKE BOX.

5. 2"CONDENSATE DRAIN, CND DOWN IN PLUMBING CHASE TO BASEMENT. REFER TO

P2.0 FOR CONTINUATION. COORDINATE HVAC TRADES.

6. VERTICAL PIPE TRANSITION UP AND DOWN, CONTINUED ON P2.0 AND P2.4. SIZE

AND SYSTEM AS NOTED.

P

R E E

NI

GN

ELANOISSEF

O R R

EG

ISTERE

D

S

T A

TE OF ID

AH

O

WAVERE

K

TYD

O J

DN

A B

C

R E

F

PF

KEY NOTES:

PLUMBING GENERAL NOTES:

1. IT IS NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH

OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS,

CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT THIS

PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.

THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.

3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS

REQUIRED BY LOCAL CODES.

4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH

OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND

ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR

ADDITIONAL DETAILS NECESSARY FOR COORDINATION.

5. ABSOLUTELY NO FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER

THE CONCRETE SLAB.

6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.

7. PROVIDE TRAP PRIMERS AND TRAP SEALS FOR ALL FLOOR DRAINS.

8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL

FIXTURES.

9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS

TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.

10.ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.

FWS

ASST.

STATE

SUPERINTENDENT

OFFICE

FWS

OFFICE

STORAGE

FWS

OFFICE

FWS

OFFICE

FWS

OPEN

OFFICE

NEPA

PLANNER

OPEN

OFFICE

ECO

OPEN

OFFICE

SMALL

CONFERENCE

ROOM

FWS

OFFICE

SECURITY

OFFICE

ECO

OFFICE

PUBLIC

AFFAIRS

OFFICER

HRM

OFFICE

VEG

OFFICE

TEC

OFFICE

NIZ

OFFICE

MEDIUM

CONFERENCE

ROOM

PRINT

ROOM

BREAK

ROOM

MENS

RESTROOM

WOMENS

RESTROOM

ELEV

AQM

OPEN

OFFICE

DEPUTY

SUP.

OFFICE

SUPERVISORS

OFFICE

SUPERVISOR

FILING

MEDIUM

CONFERENCE

ROOM

EXECUTIVE

ASSISTANT/

WAITING

VEG

OPEN

OFFICE

TEC

OPEN

OFFICE

HRM

OPEN

OFFICE

STAIR

LARGE

CONFERENCE

ROOM

STAIR

CORRIDOR

210A

WC2

WC2

WC1 WC1

WC1 UR

L1

L1

L1

L1

S1

CO

FD1

FD1

1 2 3 4 5 6 7

2 1/2" V1

4"

SAN.

4"ø SAN

EWC1

2 1/2" V

FCO

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:0 :2

P

M

P2.3

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

SECOND LEVEL UNDERFLOOR PLUMBING

PLAN

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

BJK/JTW

TJB

JTW

: 1/8" = 1'-0"P2.3E7.2

9 SECOND LEVEL UNDERFLOOR PLUMBING PLAN

1. VERTICAL PIPE TRANSITION UP AND/OR DOWN, CONTINUED ON SHEET P2.4 & P2.2.

SIZE AND SYSTEM AS NOTED.

2. PROVIDE 1/2" PEX TO FLOOR DRAIN TRAP PRIMER, TYP. ALL FLOOR DRAINS. SEE

DETAIL 9/P9.1.

P

R E E

NI

GN

ELANOISSEF

O R R

EG

ISTERE

D

S

T A

TE OF ID

AH

O

WAVERE

K

TYD

O J

DN

A B

C

R E

F

PF

FWS

ASST.

STATE

SUPERINTENDENT

OFFICE

FWS

OFFICE

STORAGE

FWS

OFFICE

FWS

OFFICE

FWS

OPEN

OFFICE

NEPA

PLANNER

OPEN

OFFICE

ECO

OPEN

OFFICE

SMALL

CONFERENCE

ROOM

FWS

OFFICE

SECURITY

OFFICE

ECO

OFFICE

PUBLIC

AFFAIRS

OFFICER

HRM

OFFICE

VEG

OFFICE

TEC

OFFICE

NIZ

OFFICE

MEDIUM

CONFERENCE

ROOM

PRINT

ROOM

BREAK

ROOM

MENS

RESTROOM

WOMENS

RESTROOM

ELEV

AQM

OPEN

OFFICE

DEPUTY

SUP.

OFFICE

SUPERVISORS

OFFICE

SUPERVISOR

FILING

MEDIUM

CONFERENCE

ROOM

225EXECUTIVE

ASSISTANT/

WAITING

VEG

OPEN

OFFICE

TEC

OPEN

OFFICE

HRM

OPEN

OFFICE

STAIR

LARGE

CONFERENCE

ROOM

WC2

WC2

WC1 WC1

WC1 UR

L1

L1

L1

L1

IM1

BVBV

2-1/2"V

FD1

FD1

S1

1-1/2"DCW

3/4"DHW,

3/4"DHWR

EWC1

2 1/2"V

3/4"ø DHWR 3/4"ø DHW 1 1/2"ø DCW

3/4"ø DHW 3/4"ø DHWR

1 1/2"ø DCW

3/4"ø DCW

WHA

1 1/2"ø V

KEY NOTES:

PLUMBING GENERAL NOTES:

1. IT IS NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH

OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS,

CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT THIS

PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.

THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.

3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS

REQUIRED BY LOCAL CODES.

4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH

OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND

ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR

ADDITIONAL DETAILS NECESSARY FOR COORDINATION.

5. ABSOLUTELY NO FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER

THE CONCRETE SLAB.

6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.

7. PROVIDE TRAP PRIMERS AND TRAP SEALS FOR ALL FLOOR DRAINS.

8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL

FIXTURES.

9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS

TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.

10.ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:0 :2

P

M

P2.4

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

SECOND LEVEL PLUMBING PLAN

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

BJK/JTW

TJB

JTW

: 1/8" = 1'-0"P2.4E7.2

9 SECOND LEVEL PLUMBING PLAN

1. VERTICAL PIPE TRANSITION UP AND/OR DOWN, CONTINUED ON PLUMBING PLAN

FOR LEVEL ABOVE AND/OR BELOW. SIZE AND SYSTEM AS NOTED.

2. PROVIDE 1/2" PEX TO FLOOR DRAIN TRAP PRIMER, TYP. ALL FLOOR DRAINS. SEE

DETAIL 9/P9.1.

3. HOT & COLD WATER DOWN IN INTERIOR WALL TO UNDER CABINETRY & OVER TO

COUNTER-MOUNTED SINK.

4. CW PIPING TO REFRIGERATOR ICE-MAKE BOX

P

R E E

NI

GN

ELANOISSEF

O R R

EG

ISTERE

D

S

T A

TE OF ID

AH

O

WAVERE

K

TYD

O J

N.T.S.

N.T.S. N.T.S. N.T.S.

N.T.S. N.T.S. N.T.S. N.T.S.

N.T.S.

CLEANOUT

TEE

FLOOR

LINE

CONNECT TO WASTE

LINE

STAINLESS STEEL

WALL COVER

AND SCREW

WALL

EXTEND WASTE OR

VENT LINE WHERE

INDICATED

M

IN

HANGER ROD

TURN BUCKLE (AS

REQUIRED)

INSULATION

PIPE

SHEET METAL

SADDLE

INSERT

CLEVIS TYPE HANGER

FOR PIPE 2" & LARGER

HANGER ROD

TURN

BUCKLE (AS

REQUIRED)

INSULATION

PIPE

SHEET

METAL

SADDLE

INSERT

PIPE STRAP TYPE

HANGER FOR PIPE

LESS THAN 2"

GFI OUTLET

FINISHED

FLOOR

ELECTRICAL

POWER CORD

2'X2'X2' SUMP PIT WITH GRATE COVER

(AT CONTRACTORS OPTION:

PROVIDE A FIBERGLASS BASIN WITH

COVER SUITABLE FOR SUMP PUMP)

ELEVATOR

SHAFT FLOOR

CHECK VALVE

SUMP PUMP:

MANUAL OPERATION

10' POWER CORD 115V

ELECTRICAL SWITCH

FINISHED

FLOOR

TERMINATE SUMP PUMP

DISCHARGE ABOVE

FINISHED FLOOR

ELEVATION WITH 3/4" HOSE

BIBB CONNECTION

1" PVC OR COPPER

DISCHARGE

A.S.M.E. T&P

RELIEF VALVE

PIPE RELIEF VALVE

DISCHARGE LINE FULL SIZE

TO FLOOR DRAIN OR

APPROVED RECEPTOR

SEISMIC BRACING PER

CODE

4" CONCRETE HOUSE

KEEPING PAD

DWH1

MANUAL FLOW BALANCE

VALVE (TYP)

DCW

120° DHW

3/4"DHWR

T

RECIRC PUMP, RCP1

TEMP GAUGE, T1 (TYP)

CHECK VALVE (TYP)

THERMOSTATIC MIXING VALVE

(SET TO 120°F)

STRAINER

1" C

W P

DHW

T&P PORT (TYP)

PRESSURE GAUGE, PG1

140° HW

1" DCW

NOTE:

PIPE THERMOSTATIC MIXING VALVE

AS PER MANUFACTURER'S WRITTEN

INSTALLATION INSTRUCTIONS

ET1

MV1

INTERIOR FLOOR CLEANOUTEXTERIOR CLEANOUT

(LIGHT TRAFFIC AREA)

SEE

PLANS

FINISHED FLOOR

DIRECTION OF FLOW

CAST IRON EXTENTION -

SAME SIZE AS SEWER UPT

TO 4" DIA.

6" THICK BY 18" SQUARE

CONCRETE PAD

"CO" TO BE CAST IN COVER

GRADE OR PAVING

CAST IRON CLEANOUT WITH

COVER FOR DUTY REQUIRED

CAST IRON LONG SWEEP 1/4

BEND OR CAST IRON COMB,

"Y" & 1/8 BEND. (USE

REDUCING TYPE WHERE

REQUIRED)

BUILDING DRAINING OR SEWER MATERIAL

AND SIZE AS SPECIFIED

1/2'' CW TO TRAP

CONNECT AS REQ'D

FIN FLOOR

1/2'' CW

UNION

FRAMED WALL

1/2'' BV

PVC SLEEVE

NOTE:

TRAP PRIMERS ARE

REQUIRED AT ALL

FLOOR DRAINS.

MOUNT PIPE IN

INTERIOR WALL

3/4" CW

SUPPLY

FREEZELESS WALL

HYDRANT WITH

VACUUM BREAKER

18" ABOVE FINISHED

GRADE OR AS NOTED

ON SCHEDULE

TRANSITION HDPE

TO COPPER

FOUNDATION WALL

DCW SERVICE -

SEE CIVIL DRAWINGS

FOR CONTINUATION

PIPE AIR GAP TO DRY WELL

BYPASS WITH LOCKING HANDLE

STRAINER

REDUCED PRESSURE BACKFLOW PREVENTOR ( BP1)

BALL VALVE (BV1) - TYP.

PRESSURE REDUCING VALVE ( PRV1)

DCW TO BUILDING

PRESSURE GAUGE ( PG1) - TYP.

WATER METER WITH PULSE SIGNAL FOR MONITORING

NOTES:

1. REMOTE WATER METER READER(S) LOCATED AS DIRECTED BY UTILITY.

2. COORDINATE TIE-IN TO OWNER'S WATER

MONITORING SYSTEMS.

1 WATER SERVICE ENTRANCE

P9.1

2 WATER HEATER

P9.1

3 THERMOSTATIC MIXING VALVE

P9.1

4 FREEZELESS WALL HYDRANT

P9.1

5 WALL CLEANOUT

P9.1

6 FLOOR CLEANOUT

P9.1

7 PIPE HANGER

P9.1

8 TRAP PRIMER - IN FINISHED LOCATION

P9.1

1" DOMESTIC HOT

WATER TO BUILDING

1" DOMESTIC HOT WATER FROM

WATER HEATER, ISOLATE WITH

BALL VALVE

1" DOMESTIC COLD WATER

FROM SERVICE, ISOLATE W/

BALL VALVE

MIXED WATER TEMPERATURE

DISPLAY

9 ELEVATOR SUMP

P9.1

TRAP PRIMER IN

WALL BOX. SECURE

TO WALL FRAMING

"LOCKABLE" ACCESS

PANEL - COORDINATE

LOCATION W/ ARCHITECT

CONNECT TO

CW PIPE IN WALL

FLOOR DRAIN W/ TRAP

PRIMER CONNECTION

NOTES:

1. PROVIDE REMOTE WATER METER READER AND LOCATE AS REQUIRED BY LOCAL UTILITY.

2. PROVIDE LOCKING SHUTOFF VALVES ON BYPASS LINE. BYPASS LINE MAY BE SMALLER THAN MAIN LINE

(GENERALLY 1/2 MAIN LINE). BYPASS MUST HAVE SAME TYPE OF BACKFLOW PROTECTION AS MAIN LINE.

3. BACK FLOW PREVENTERS SHALL BE MOUNTED 18" MIN ABOVE FLOOR AND NO MORE THAT 48" MAX

ABOVE FLOOR MIN. 6" FROM WALLS, ETC. MUST BE ACCESSIBLE WITH NO OBSTRUCTIONS

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:0 :2

P

M

P9.1

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

PLUMBING DETAILS

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

BJK/JTW

TJB

JTW

P

R E E

NI

GN

ELANOISSEF

O R R

EG

ISTERE

D

S

T A

TE OF ID

AH

O

WAVERE

K

TYD

O J

PS

FS

TS

FAA SS

FACP SD

D SD

D

F H

F

S Sxx WP

Sx SC

X

D-1

PS-X

X

X

X

X

J

TV

X

LP100

208/120V 3#. 4W

M

M

M

SPD VFD

LA

PFC G

M CB

Y

CR EL

RE MD

DC GB

ES C

KP s

S

X

OS

DT

OS

DT

P

DT

OS R1

P R2

LV R3

R4

PROJECT NOTES:

1. THIS PROJECT IS PART OF A PHASED PROJECT. MANY ELECTRICAL SYSTEMS MUST BE

ABLE TO INTEGRATE WITH THE EXISTING SYSTEMS, INCLUDING BUT NOT LIMITED TO FIRE

ALARM, ELECTRICAL METERS, SECURITY, INTERCOM. SEE DETAILS FOR MORE

INFORMATION.

2. PRIOR TO BID CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK REQUIRED TO

COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL

BECOME THOROUGHLY FAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETE THE

PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID.

3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL ELECTRICAL

SERVICE WORK WITH UTILITY. OWNER PAYS ALL FEES, CONTRACTOR DOES ALL

SCHEDULING AND COORDINATION OF WORK. IT IS THE SOLE RESPONSIBILITY OF THE

CONTRACTOR TO ENSURE ALL SCHEDULES ARE MET.

4. GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE

WITH NECA 1, "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL

CONTRACTING." THIS PUBLICATION IS AVAILABLE FROM NECA BY TELEPHONE AT

301-657-3110 OR ON-LINE AT WWW.NECANET.ORG.

5. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH MECHANICAL FOR

PLENUM SPACES AND PROVIDE PLENUM RATED CABLES WHERE REQUIRED FOR LIGHTING

CONTROL, DATA, FIRE ALARM AND ALL OTHER L.V. SYSTEMS NOT INSTALLED IN CONDUIT.

VERIFY CONDUIT REQUIREMENTS ON DRAWINGS AND SPECIFICATIONS.

6. FIRE-RESISTANCE: PROVIDE A MINIMUM HORIZONTAL DISTANCE OF 24" BETWEEN OUTLET

BOXES LOCATED ON OPPOSITE SIDES OF FIRE-RESISTANCE RATED WALLS. WHERE THIS IS

NOT POSSIBLE INSTALL UL LISTED PUTTY PADS ON ALL OUTLET BOXES NOT MEETING THE

24" SEPARATION. PROVIDE A UL LISTED THROUGH -PENETRATION FIRESTOP FOR

PENETRATIONS OF FIRE-RESISTANCE RATED ASSEMBLIES.

7. CONDUCTORS ARE SIZED PER THE 75 DEGREE C RATING COLUMN OF NEC TABLE 310.16. IF

THE TERMINAL USED FOR A TERMINATION OF A PARTICULAR CONDUCTOR IS NOT MARKED,

OR THE TERMINAL IS MARKED FOR 60 DEGREE C CONDUCTORS, IT IS THE RESPONSIBILITY

OF THE CONTRACTOR TO EITHER ADJUST THE AMPACITY OF THE CONDUCTOR TO MATCH

THE 60 DEGREE COLUMN OF TABLE 310.16, OR REPLACE THE TERMINAL WITH ONE RATED

FOR AT LEAST 75 DEGREES C

8. BASED ON ACTUAL HOMERUN LENGTHS REQUIRED IN THE FIELD, THE CONTRACTOR SHALL

CALCULATE AND INCREASE THE WIRE SIZES AS REQUIRED TO LIMIT BRANCH CIRCUIT

VOLTAGE DROP TO 3%. FOR 20A BRANCH CIRCUITS THE MINIMUM CONDUCTOR SIZES

SHALL BE AS FOLLOWS: #10 AWG CU FOR RUNS BETWEEN 100 TO 200 LINEAR FEET, #8

AWG CU FOR RUNS BETWEEN 200 AND 325 LINEAR FEET, AND AS CALCULATED BY THE

CONTRACTOR FOR CIRCUITS EXTENDING BEYOND 325 LINEAR FEET. IN ALL CASES WHERE

WIRE SIZES INCREASE, THE CONTRACTOR SHALL PROVIDE LARGER CONDUITS AS

REQUIRED.

9. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V BRANCH CIRCUIT.

ABBREVIATIONS

A or AMP AMPERES

AC ALTERNATING CURRENT

A/C AIR CONDITIONING

AF AMP FUSE

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHU AIR HANDLING UNIT

AL ALUMINUM

AS AMP SWITCH

ATS AUTOMATIC TRANSFER SWITCH

BAS BUILDING AUTOMATION SYSTEM

BKR BREAKER

C RACEWAY/CONDUIT

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CKT CIRCUIT

CLG CEILING

C.O. RACEWAY/CONDUIT ONLY, WITH PULL STRING

CNTRL CONTROL

CR CARD READER

CU COPPER

DISC DISCONNECT

DIST DISTRIBUTION

DPDT DOUBLE POLE DOUBLE THROW

DWG DRAWING

EA EACH

EF EXHAUST FAN

ELEC ELECTRIC

EMT ELECTRICAL METALLIC TUBING

EQUIP EQUIPMENT

EX OR

EXIST

EXISTING

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

FATC FIRE ALARM TERMINAL CABINET

FD FUSED DISCONNECT

FLR FLOOR

FO FIBER OPTIC

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

GEC GROUNDED ELECTRODE CONDUCTOR

GFI GROUND FALUT INTERRUPTER

GND GROUND

GRC GALVANIZED RIGID CONDUIT

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HPS HIGH PRESSURE SODIUM

HTR HEATER

HVAC HEATING, VENTILATING & AIR CONDITIONING

HZ HERTZ

J-BOX JUNCTION BOX

KVA KILOVOLT AMPERES

KW KILOWATTS

LTG LIGHTING

LPW LUMENS PER WATT

MAG MAGNETIC STARTER

MAN MANUAL

MAX MAXIMUM

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MH METAL HALIDE

MIN MINIMUM

MSS

MOTOR STARTER SWITCH WITH THERMAL

OVERLOADS

N NEUTRAL

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA

NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NFD NON-FUSED DISCONNECT

NIC NOT IN CONTRACT

NO NORMALLY OPEN

# NUMBER

OAE OR APPROVED EQUAL

OC ON CENTER

OCPD OVERCURRENT PROTECTION DEVICE

OH OVERHEAD

P POLE

PB PUSHBUTTON

PNL PANEL

PoE POWER-OVER-ETHERNET

PVC POLYVINYL CHLORIDE CONDUIT

PWR POWER

RECEPT RECEPTACLE

RCPT RECEPTACLE

RGS RIGID GALVANIZED STEEL

RM ROOM

RVNR REDUCED VOLTAGE NON-REVERSING

SP SINGLE POLE TOGGLE SWITCH

SPEC SPECIFICATION

SPST SINGLE POLE SINGLE THROW

SSPB START-STOP PUSHBUTTON

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

TB TELEPHONE BOARD

TC TIME CLOCK

TD TIME DELAY

TEL TELEPHONE

TSP TWISTED SHIELDED PAIR

TTB TELEPHONE TERMINAL BOARD

TYP TYPICAL

UG UNDERGROUND

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

UON UNLESS OTHERWISE NOTED

V VOLT

VA VOLT AMPERES

VFD VARIABLE FREQUENCY DRIVE

W WATTS

WAO WORK AREA OUTLET

WP WEATHERPROOF

W/O WITHOUT

XFMR TRANSFORMER

Y WYE CONNECTED

DELTA CONNECTED

PHASE

*THESE ABBREVIATIONS COMPRISE A STANDARD LIST;

NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT.

ELECTRICAL SYMBOL LEGEND: SYSTEM PLANS

SYMBOL DESCRIPTION DESCRIPTION SYMBOL

TELEPHONE OUTLET; PROVIDE ROUGH IN ONLY. 2-GANG

BOX W/MUD RING AND 1" STUBBED UP TO ACCESSIBLE

CEILING SPACE. (MOUNT AT +18" AFF. UNO.)

SPRINKLER PRESSURE SWITCH

VOICE-DATA OUTLET; PROVIDE ROUGH IN ONLY. 2-GANG

BOX W/MUD RING AND 1" STUBBED UP TO ACCESSIBLE

CEILING SPACE. (MOUNT AT +18" AFF. UNO.)

SPRINKLER FLOW SWITCH

CABLE TRAY OR BASKET TRAY. SEE SYSTEMS PLANS FOR

DIMENSIONS AND MOUNTING HEIGHT.

SPRINKLER TAMPER SWITCH

FIRE ALARM ANNUNCIATOR PANEL

SINGLE-STATION SMOKE DETECTOR. PROVIDE 120V AND

MONITOR AT FACP VIA RELAY

FIRE ALARM CONTROL PANEL SMOKE DETECTOR - PHOTO-ELECTRIC

DOOR HOLDER

SMOKE DETECTOR "D" INDICATES DUCT SMOKE

DETECTOR.

FIRE ALARM MANUAL STATION (MOUNT AT +46" AFF, UNO.) HEAT DETECTOR

STROBE WALL MOUNT (MOUNT AT +82" AFF, UNO.) AND

CEILING MOUNT

HORN/STROBE WALL MOUNT (MOUNT AT +82" AFF, UNO.)

AND CEILING MOUNT

SPEAKER - CEILING MOUNT, WALL MOUNT (SEE GENERAL

NOTE "D" ON PLANS FOR SPEAKER NOTATIONS. MODEL

NUMBERS ARE GIVEN ON SHEET E9.5)

WIRELESS POINT CONNECTION:

SUPPLY CAT6 CABLING TO THIS LOCATION (CLG).

SPEAKER - SUSPEND FROM CEILING (SEE GENERAL NOTE

"D" ON PLANS FOR SPEAKER NOTATIONS. MODEL NUMBERS

ARE GIVEN ON SHEET E9.5)

SPEAKER CONTROLLER

ELECTRICAL SYMBOL LEGEND: POWER PLANS

SYMBOL DESCRIPTION DESCRIPTION SYMBOL

BRANCH CIRCUIT PANELBOARD RACWAY STUB-OUT OR STUB-UP WITH CAPPED END

PANEL AND CIRCUIT DESIGNATION ARE SHOWN NEXT

TO EACH DEVICE (PANEL NAME - CIRCUIT NUMBER).

BRANCH CIRCUIT WIRE SIZE IS #12 UNLESS NOTED

OTHERWISE. A SINGLE INSULATED GREEN GROUND

CONDUCTOR SHALL BE PROVIDED WITH EACH HOME

RUN. PROVIDE A SEPARATE NEUTRAL FOR EACH

CIRCUIT. HOME RUNS SHALL HAVE NO MORE THAN

THREE CIRCUITS. LINE VOLTAGE AND LOW VOLTAGE

WIRING IS NOT SHOWN ON PLANS. FOR EQUIPMENT

CIRCUITING, SEE MEP COORDINATION SCHEDULE.

SURFACE MOUNTED PLUGSTRIP. SUBSCRIPT DENOTES

TYPE AND STYLE. SEE TABLE BELOW:

TYPE A: PLUGSTRIP, POWER ONLY, OUTLET EVERY 3' OC

TYPE B: WIREMOLD SERIES 4000 POWER AND DATA

TYPE C: WIREMOLD SERIES 5400 POWER AND DATA

DUPLEX RECEPTACLE. (MOUNT AT +18" AFF. UNO.)

X-GFI-GFCI RECEPTACLE

WP-WEATHER PROOF WITH WHILE IN USE COVER

4PLEX RECEPTACLE. (MOUNT AT +18" AFF. UNO.)

X-GFI-GFCI RECEPTACLE

WP-WEATHER PROOF WITH WHILE IN USE COVER

LINE BREAK

ABOVE COUNTER DUPLEX RECEPTACLE MOUNTED 4"

ABOVE BACKSPLASH

SURFACE MOUNTED RACEWAY

ABOVE COUNTER 4PLEX RECEPTACLE MOUNTED 4"

ABOVE BACKSPLASH

RACEWAY CONCEALED IN WALL, FLOOR, OR CEILING IN

FINISHED SPACES, EXPOSED IN UNFINISHED

SPACES.

FLOOR OUTLET - HUBBEL MODEL #HBLCFB401CB

WITH COVER MODEL #HBLTCGNTBKSW, OR EQUAL.

RACEWAY BELOW FLOOR OR BELOW GRADE

FLOOR BOX WITH COMBINATION 4PLEX RECEPTACLE

AND 2 TELEPHONE/DATA OUTLETS. USE EVOLUTION

SERIES 8AT, OR EQUAL.

RACWAY STUB-OUT OR STUB-UP WITH BUSHED END

JUNCTION BOX GROUNDING BUS

FLATSCREEN TV BOX; 2-GANG, FLUSH IN WALL,

HUBBELL RACO NSAV62M WITH NSAV6C COVER.

DUPLEX RECEPTACLE AND SINGLE GANG DATA PORT

AND ALL CCTV CABLE CONNECTIONS. (MOUNT AT

+72" AFF. UNO.)

PUSHBUTTON (MOUNT AT +54" AFF, UNO.)

-EPO EMERGENCY POWER OFF

-ADA HANDICAP ACCESSIBLE DOOR (DEVICE BY OTHERS)

-ODO OVERHEAD DOOR OPERATOR (DEVICE BY OTHERS)

SPECIAL PURPOSE OUTLET.

(MOUNT AT +18" AFF. UNO.)

POWERED FURNITURE CONNECTION

1. THESE SYMBOLS COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT.

2. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR. MOUNTING HEIGHTS INDICATED ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGS OR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED.

ELECTRICAL SYMBOL LEGEND: 1-LINES

SYMBOL DESCRIPTION DESCRIPTION SYMBOL

SWITCH BOARD OR PANEL BOARD; NAME, VOLTAGE,

PHASE, NUMBER OF WIRES WHEN INDICATED

DISCONNECT SWITCH ("XXAS' = SWITCH AMP RATING)

CT AND CUSTOMER POWER METER

FUSED DISCONNECT SWITCH ("XXAS/XXAF" - SW AND FUSE

AMP RATING)

MOTOR SYMBOL

COMBINATION MOTOR STARTER (STR SIZE, TYPE, AS, AF,

SEE MEP COORD. SCHEDULE)

UTILITY ELECTRIC METER AND BASE (BASE BY

CUSTOMER)

AUTOMATIC TRANSFER SWITCH

SURGE PROTECTION DEVICE VARIABLE FREQUENCY DRIVE

LIGHTNING ARRESTOR FIXED MOUNT LV BREAKER

STRESS RELIEF CONE FUSED SWITCH ("XXAS/XXAF" = SW AND FUSE AMP RATING)

POWER FACTOR CORRECTION CAPACITOR GENERATOR

MOTOR STARTER SWITCH WITH THERMAL OVERLOADS WALL MOUNTED BREAKER

CONTRACTOR NORMALLY OPEN, NORMALLY CLOSED THERMAL OVERLOAD ELEMENT

TRANSFORMER

3-PHASE, 3-WIRE DELTA CONNECTION Δ

3-PHASE, 4 WIRE GROUNDED WYE CONNECTION

ELECTRICAL SYMBOL LEGEND: SECURITY SYSTEMS

SYMBOL DESCRIPTION DESCRIPTION SYMBOL

CARD READER (SEE ELECTRICAL DETAILS FOR

REQUIREMENTS.)

ELECTRIC LOCK

REQUEST TO EXIT MOTION DETECTOR MOTION DETECTOR

DOOR CONTACTS GLASS BREAK DETECTOR

ELECTRIC STRIKE

CEILING MOUNT CCTV CAMERA - PROVIDE CAT6 IN 1" C.

FOR ALL CAMERA LOCATIONS. SEE ELECTRICAL DETAILS

FOR SYSTEM REQUIREMENTS.

KEY PAD SECURITY SPEAKER/ALARM

SECURITY STROBE/ALARM

ELECTRICAL SYMBOL LEGEND: LIGHTING PLANS

SYMBOL DESCRIPTION DESCRIPTION SYMBOL

1X4 SURFACE WALL MOUNT FLUORESCENT PENDANT FIXTURE; HIGH BAY, LOW BAY, DECORATIVE.

1X4 2X2 2X4 RECESSED FLUORESCENT, 'a', AND 'b'.DESIGNATES SWITCH LEGS.

EXIT SIGN. ARROW(S) INDICATE DIRECTION OF TRAVEL,

SHADED AREA INDICATES ILLUMINATED FACE(S). STEM

INDICATES WALL MOUNTED. CELING MOUNTED

OTHERWISE.

1X4 2X2 2X4 RECESSED EMERGENCY FLUORESCENT,

'a', AND 'b'.DESIGNATES SWITCH.

EMERGENCY EGRESS BATTERY PACK, WALL MOUNT OR

CEILING MOUNT

1X4 2X2 2X4 SURFACE OR PENDANT FLUORESCENT,

'x' DESIGNATES SWITCH LEG.

WALL MOUNTED SCONCE OR WALLPACK FIXTURE

1X4 2X2 2X4 SURFACE OR PENDANT EMERGENCY

FLUORESCENT, 'x' DESIGNATES SWITCH LEG.

SURFACE MOUNTED DOWNLIGHT

4' FLUORESCENT STRIP OR INDUSTRIAL, SURFACE

OR CHAIN HUNG

RECESSED CAN DOWNLIGHT

POLE MOUNTED FIXTURE RECESSED CAN WALLWASHER

LIGHTED BOLLARD

TRACK LIGHTING. SEE FIXTURE SCHEDULE AND

LIGHTING PLANS.

STANDARD LIGHTING CONTROLS: SWITCHES AND LINE VOLTAGE DIMMERS

TOGGLE SWITCH (MOUNT AT 46" AFF. UNO.)

SUBSCRIPTS:

X- SINGLE POLE

3- THREE-WAY

4- FOUR-WAY

D- DIMMER SWITCH - PHILIPS SUNRISE DIMMER -

ON/OFF.

K- KEYED SWITCH

SUBSCRIPTS: (CONTINUED)

T- TIMER

P- PILOT LIGHT

OS-WALL SWITCH OCC SENSOR. WATTSTOPPER

DW100(SINGLE SWITCH OR DW-200 DUAL SWITCH).

a- SINGLE POLE LIGHTING SWITCH FOR ZONE a b- SINGLE POLE LIGHTING SWITCH FOR ZONE b ab- LIGHTING SWITCHES WITH MULTIPLE ZONES

CEILING MOUNT OCCUPANCY SENSOR. WATT

STOPPER DT-300 DUAL TECHNOLOGY CEILING

MOUNT OR EQUAL WITH BZ-50 POWER PACKS AS

NEEDED.

WALL MOUNT OCCUPANCY SENSOR. WATT STOPPER

DT-200 DUAL TECHNOLOGY WALL MOUNT OR EQUAL

WITH BZ-50 POWER PACKS AS NEEDED.

PHOTOCELL. WATT STOPPER LS-301 CEILING MOUNT

OR EQUAL

DIGITAL LIGHTING CONTROLS: ROOM CONTROLLERS AND LOW VOLTAGE DEVICES

OCCUPANCY SENSOR. WATT STOPPER LMDC-100

DUAL TECHNOLOGY CEILING MOUNT OR EQUAL

ROOM CONTROLLER. WATT STOPPER DLM LMRC-101 OR

EQUAL.

PHOTOCELL. WATT STOPPER DLM LMLS-400 CEILING

MOUNT OR EQUAL

ROOM CONTROLLER. WATT STOPPER DLM LMRC-102 OR

EQUAL.

LOW VOLTAGE SWITCH; WATTSTOPPER LMSW-10X,

"X" DENOTES NUMBER OF BUTTONS

DIMMING ROOM CONTROLLER. WATT STOPPER DLM

LMRC-212 OR EQUAL.

DIMMING ROOM CONTROLLER. WATT STOPPER DLM

LMRC-213 OR EQUAL.

16147

P R

O

FE

SS IONAL ENG INEE

RL

I C E N S ED

S T

A

T E O F I D

A H

O

A R

I AN

C . B LOOMF

I E L

D

OFFICE BIDDING OPTIONS

• BASE BID: PHASE 3 - OFFICE.

• OPTION ITEM #1: INFORMATION BUILDING

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:3 :4

P

M

E0.1

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

SYMBOLS & ABBREVIATIONS

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

RJH

BMM

ACB

16147

P R

O

FE

SS IONAL ENG INEE

RL

I C E N S ED

S T

A

T E O F I D

A H

O

A R

I AN

C . B LOOMF

I E L

D

A B

C

R E

F

R E

F

G

G

D

Y

H

D

YH

D

YH

E5E5E5E5

TO TEL/COMM RM 002

TO BUILDING SERVICE DISCONNECT

TO PANEL L1 & EXTERIOR

LIGHTING CONTROL

L1- 2

L1- 2

L1- 2

L1- 2

L1- 2

L1- 2

L1- 2

L1- 2

L1- 2

L1- 2

E7

E7

E7

E7

E7

E7

E6

E6

E6

E6

PROVIDE #10AWG

IN EX 1"C.

PROVIDE #8AWG IN EX 1"C.

L1- 4 L1- 4 L1- 4 L1- 4

#10AWG IN 1"C.

E5 L1- 4

E5

L1- 4

E5 L1- 4

EX 12"X12" BOX

PROVIDE #10AWG IN 1"C.

PROVIDE #10AWG

IN EX 1"C. (TYP)

EXISTING FLAG POLE

AND LIGHTS

EX C.O. FROM

PHASE 1

NEW

EX EX

ALL PAVILION LTG (TYPE E9)

ON CIRCUIT L1- 6

E9E9

E9E9E9

E9E9E9E9E9

E9E9E9E9

PAVILION

KEY NOTES:

GENERAL NOTES:

A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE

WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF

DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS

PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS,

WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN

THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF

HOLES TO THE SATISFACTION OF THE CONTRACTING OFFICER.

C. THE TEL/DATA DESIGN INTENT: ELECTRICAL CONTRACTOR PROVIDES BOX AND

CONDUIT TO ACCESSIBLE CEILING. CABLING CONTRACTOR SHALL PULL CABLING

FROM WORK AREA OUTLET (WAO) BACK TO THE I.T. ROOM IN BASEMENT IN OPEN

RACEWAY (UTILIZE D-RINGS AND J-HOOKS). 2 DATA, 1 PHONE, CAT6 TO EACH

WAO. POWERED FURNITURE TO GET 3 DATA, 1 PHONE, CAT6. COIL IN THE I.T.

ROOM AS SPECIFIED. DO NOT ALLOW COILS TO SIT ON THE FLOOR. PULL AND

TERMINATE FIBER BETWEEN EACH BUILDING. TEST ALL CAT6 AND FIBER AS

SPECIFIED. INSTALL RACKS AS SPECIFIED. ALL PATCH PANELS AND OTHER

SERVER EQUIPMENT IS BY CONTRACTING OFFICER. TEL/DATA OUTLETS IN THE

FURNITURE; HOMERUN CABLING THROUGH FURNITURE RACEWAY TO NEAREST

TELECOMMUNICATION ROOM. ROUTE POWER THROUGH THE BOTTOM CHANNEL.

TEL/DATA CABLING SHALL BE ROUTED THROUGH THE TOP CHANNEL.

D. SOUND MASKING/PAGING/MUSIC ZONE PROGRAMMING DESCRIPTION: "a" = SOUND MASKING, INTERCOM & MUSIC, "b" = MUSIC & INTERCOM ONLY, "c" = INTERCOM

ONLY. S1 SPEAKER ARE TO BE MOUNTED IN CEILING. S2 SPEAKERS ARE TO BE

SUSPENDED ABOVE CEILING IN OPEN OFFICE AREAS.

E. ELECTRICAL CONTRACTOR SHALL PROVIDE COMPLETE WIRED SYSTEMS FOR

ALL SECURITY ITEMS AND SPEAKERS. COORDINATE WITH CONTRACTING

OFFICER AND MANUFACTURERS FOR ALL REQUIREMENTS.

- SOUND MASKING/INTERCOM (SEE DETAIL 9 ON SHEET E9.5)

- ACCESS CONTROL TIED INTO INTRUSION SYSTEM WITH CLASS BREAK

DETECTION AND DOOR CONTACTS (SEE SHEET E9.3)

- CAMERA SYSTEM (SEE SHEET E9.3)

F. PROVIDE CLEAR PLASTIC COVERS FOR ALL FIRE ALARM MANUAL PULL

STATIONS.

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:3 :5

P

M

E1.1

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

ELECTRICAL SITE PLAN

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

RJH

BMM

ACB

: 1" = 30'-0"E1.1E1.1

9 PHASE 3 - ELECTRICAL SITE PLAN

1. EXISTING 24"X36" PULL BOXES CONTAIN: (1) 1"C.O. FIRE ALARM, (2) 2"C.O. FIBER,

(1) 2"C.O. COPPER, (3) 3-1/2"C.O. ELECTRICAL SERVICE, (3) 3-1/2"C.O. SPARE. SEE

TRENCH DETAIL ON SHEET E9.1. IN POWER 24"X36" BOX. STUB ELECTRICAL

SERVICE AND (2) SPARES FROM THIS LOCATION TO OFFICE ELECTRICAL SERVICE

DISCONNECT ON LOWER LEVEL. IN TEL/COMM 24X36" BOX. STUB ALL

SIGNALING,CONTROLLING, SECURITY, AND (1) SPARE FROM THIS LOCATION TO

TEL/COMM 002 ON LOWER LEVEL.

2. PROVIDE #8AWG IN 1"C. FOR PARKING/DRIVE AREA LIGHTING. PROVIDE #10AWG

IN 1"C. IN SAME TRENCH TO PROVIDE POWER LIGHTING IN PAVILION.

3. MOUNT PAVILION LIGHTING TO BOTTOM OF SOFFIT AND CENTERED BETWEEN

RAFTERS.

4. PROVIDE CABLE IN CONDUITS TO NEW BUILDING PER ONE-LINE DIAGRAM ON

SHEET E9.1. PROVIDE 24-PAIR, SINGLE MODE FIBER FROM RACK BACK TO

WAREHOUSE SERVER ROOM. UTILIZE CONDUITS SHOWN BETWEEN BUILDINGS.

IN SECOND COMMUNICATIONS CONDUIT PROVIDE 50 PAIR COPPER BETWEEN

BUILDINGS. SEE FIBER DETAIL 11 ON SHEET E9.4 FOR COMMUNICATIONS

CABLING.

5. ALL LIGHT POLE BASES AND CONDUIT IN PARKING LOT ARE EXISTING FROM

PHASE 1. PROVIDE POLE, LUMINAIRE, AND CONDUCTORS.

NORTH

R

O

FE

SS IONAL ENG INEE

RL

I C E N S ED

S T

A

T E O F I D

A H

O

A R

I AN

C . B LOOMF

I E L

D

A B

C

UP

M

M J

J

J

J

M

J

J

J

J F.S.D.

RELAY

F.S.D.

RELAY

F.S.D.

RELAY

C

MECHANICAL

ROOM

ELEV.

FOYER

STORAGE

BUILDING

STORAGE

MDP

M1

C1

MDR

GFIGFI SUMP PUMP

OWNER METER

TEL/COMM

R1A- 6 C1- 3

R1A- 4

R1A- 12

R1A- 6

R1A- 4

C1- 3 R1A- 4

C1- 1

C1- 1

R1A- 4

C1- 17C1- 13C1- 9 C1- 7

C1- 11 C1- 15

L1- 1 M1- 1

BUSSMAN

SHUNT TRIP

M2

M1- 32

EF-1

ELEVATOR CAR LIGHT

BREAKERS

C1- 5

C1- 5

DESK LOCATION

CAMERA DVR IN RACK

GFI

CR POWER

C1- 1

CR

POWER

R1A- 8

R1A- 58

R1A- 60

M1- 24,26,28

DWH1

R1A- 54

R1A- 56

SECURITY

PANEL

INTRUSION

PANEL

M1- 36

FSD

M1- 36

FSD

M1- 36

FSD

GFI

GFI

R1A- 8

GFI

R1A- 8

GFI

STUB (2) 1" C.O. TO EXTERIOR

FOR FUTURE IRRIGATION

BAS PANEL

KEY NOTES:

GENERAL NOTES:

A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE

WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF

DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS

PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS,

WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN

THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF

HOLES TO THE SATISFACTION OF THE CONTRACTING OFFICER.

C. THE TEL/DATA DESIGN INTENT: ELECTRICAL CONTRACTOR PROVIDES BOX AND

CONDUIT TO ACCESSIBLE CEILING. CABLING CONTRACTOR SHALL PULL CABLING

FROM WORK AREA OUTLET (WAO) BACK TO THE I.T. ROOM IN BASEMENT IN OPEN

RACEWAY (UTILIZE D-RINGS AND J-HOOKS). 2 DATA, 1 PHONE, CAT6 TO EACH

WAO. POWERED FURNITURE TO GET 3 DATA, 1 PHONE, CAT6. COIL IN THE I.T.

ROOM AS SPECIFIED. DO NOT ALLOW COILS TO SIT ON THE FLOOR. PULL AND

TERMINATE FIBER BETWEEN EACH BUILDING. TEST ALL CAT6 AND FIBER AS

SPECIFIED. INSTALL RACKS AS SPECIFIED. ALL PATCH PANELS AND OTHER

SERVER EQUIPMENT IS BY CONTRACTING OFFICER. TEL/DATA OUTLETS IN THE

FURNITURE; HOMERUN CABLING THROUGH FURNITURE RACEWAY TO NEAREST

TELECOMMUNICATION ROOM. ROUTE POWER THROUGH THE BOTTOM CHANNEL.

TEL/DATA CABLING SHALL BE ROUTED THROUGH THE TOP CHANNEL.

D. SOUND MASKING/PAGING/MUSIC ZONE PROGRAMMING DESCRIPTION: "a" = SOUND MASKING, INTERCOM & MUSIC, "b" = MUSIC & INTERCOM ONLY, "c" = INTERCOM

ONLY. S1 SPEAKER ARE TO BE MOUNTED IN CEILING. S2 SPEAKERS ARE TO BE

SUSPENDED ABOVE CEILING IN OPEN OFFICE AREAS.

E. ELECTRICAL CONTRACTOR SHALL PROVIDE COMPLETE WIRED SYSTEMS FOR

ALL SECURITY ITEMS AND SPEAKERS. COORDINATE WITH CONTRACTING

OFFICER AND MANUFACTURERS FOR ALL REQUIREMENTS.

- SOUND MASKING/INTERCOM (SEE DETAIL 9 ON SHEET E9.5)

- ACCESS CONTROL TIED INTO INTRUSION SYSTEM WITH CLASS BREAK

DETECTION AND DOOR CONTACTS (SEE SHEET E9.3)

- CAMERA SYSTEM (SEE SHEET E9.3)

F. PROVIDE CLEAR PLASTIC COVERS FOR ALL FIRE ALARM MANUAL PULL

STATIONS.

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

/1

/2

:3 :5

P

M

E2.0

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

LOWER LEVEL POWER PLAN

13083

INRC OFFICE BUILDING

PHASE 3

USDA FOREST SERVICE

RJH

BMM

ACB

: 1/8" = 1'-0"E2.0E2.0

6 PHASE 3 - LOWER LEVEL POWER PLAN

1. SERVER RACK RECEPTACLES: PROVIDE (2) TYPE 5-20R

DEDICATED RECEPTACLE WITH ISOLATED GROUND, MOUNTED TO

LADDER TRAY ABOVE EACH SERVER RACK. COORDINATE EXACT

SERVER RACK LOCATION WITH CONTRACTING OFFICER, PRIOR

TO ROUGH-IN. (TYPICAL FOR ALL SERVER RACKS)

2. PROVIDE 8FT TALL BY 16FT LONG PAINTED PLYWOOD TTB.

3. VERIFY EXACT LOCATION WITH CONTROLS CONTRACTOR.

R

O

FE

SS IONAL ENG INEE

RL

I C E N S ED

S T

A

T E O F I D

A H

O

A R

I AN

C . B LOOMF

I E L

D

UP

A B

C

R E

F

UP

DN

PF

PF

M

M

M

M

M

M

M

M

M

M

M

M

M M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

J

J

J

J

J

J

JJJ

JJJ

J

M

J

M

J

M

J

M

J

M

J

M

J

M J

M

J

M

J

M

J

M

J

M

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J J

J

M

SD

D

SD

D

J J

J F.S.D.

RELAY

F.S.D.

RELAY

F.S.D.

RELAY

J

S

S

TV

TV

LARGE

MEETIN…