Drawings_Part_6_2018_06-01.pdf

PDF 7 MB Posted

Attached to
INRC - Phase III
Solicitation number
12034318R0017
Issued by

About this file

This notice provides information about an upcoming federal contract opportunity for construction services. The Interagency Natural Resources Center in Coeur d'Alene, Idaho is soliciting proposals for Phase III of its construction, which will involve building a 29,000 square foot main office supporting 173 employees from the U.S. Fish and Wildlife Service, Bureau of Land Management, and U.S. Forest Service. The project's estimated value is between $5-10 million. Interested offerors should monitor the site for a solicitation to be posted on June 5th, with proposals due 30 days thereafter. The Northern Region of the U.S. Forest Service will award the firm fixed price construction contract.

16 J-3 Drawings Part 6

View the file

Other files

File Type Posted
INRC_Second_Floor.dwg DWG drawing
INRC_First_Floor.dwg DWG drawing
7-12-18_Q&A.XLSX XLSX spreadsheet
Amendment_0002.pdf PDF
Revised_B-1.pdf PDF
Questions_and_Answers_062918.pdf PDF
L1.5_(rev1).pdf PDF
125900_SF_-_SYSTEMS_FURNITURE.pdf PDF
Amendment_0001.pdf PDF
CV_(rev1).pdf PDF
S0.1_(rev1).pdf PDF
C1.3_(rev1).PDF PDF
Prebid_Notes_6-19-18.pdf PDF
Prebid_Attendance.pdf PDF
Questions_and_Answers_061818.pdf PDF
Part_2_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_1_2018_06-01.pdf PDF
Drawings_Part_13_2018_06-01.pdf PDF
Drawings_Part_9_2018_06-01.pdf PDF
Drawings_Part_3_2018_06-01.pdf PDF
Drawings_Part_12_2018_06-01.pdf PDF
J-5_Past_Performance_Questionnaire.pdf PDF
Part_4_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_4_2018_06-01.pdf PDF
Drawings_Part_5_2018_06-01.pdf PDF
Drawings_Part_2_2018_06-01.pdf PDF
Drawings_Part_11_2018_06-01.pdf PDF
Part_5_Project_Manual_2018_06_01.pdf PDF
Part_6_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_8_2018_06-01.pdf PDF
J-1_Wage_Rate_Decision_ID180031_Mod_3_Dated_05112018.pdf PDF
Drawings_Part_10_2018_06-01.pdf PDF
Drawings_Part_14_2018_06-01.pdf PDF
Short_Set_Solicitation_12034318R0017_Final_06072018.pdf PDF
J-4_State_of_Idaho_Workers'_Insurance.pdf PDF
Part_3_Project_Manual_2018_06_01.pdf PDF
Drawings_Part_7_2018_06-01.pdf PDF
Solicitation_12034318R0017_Final_06072018.pdf PDF
Part_7_Project_Manual_2018_06_01.pdf PDF
Part_1_Project_Manual_2018_06_01.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A B

C

A

C

E

D

B

FWS

OFFICE

FWS

OFFICE

FWS

OFFICE

NEPA

PLANNER

OPEN

OFFICE

LARGE

CONFERENCE

ROOM

FWS

ASST.

STATE

SUPERINTENDENT

OFFICE

DEPUTY

SUP.

OFFICE

SUPERVISORS

OFFICE

EXECUTIVE

ASSISTANT/

WAITING

SUPERVISOR

FILING

MEDIUM

CONFERENCE

ROOM

HRM

OPEN

OFFICE

STAIR 1

FWS

OFFICE

PUBLIC

AFFAIRS

OFFICER

HRM

OFFICE

NIZ

OFFICE

MEDIUM

CONFERENCE

ROOM

SECURITY

OFFICE

ECO

OFFICE

VEG

OFFICE

TEC

OFFICE

TEC

OPEN

OFFICE

AQM

OPEN

OFFICE

VEG

OPEN

OFFICE

PRINT

ROOM

ECO

OPEN

OFFICE

CORRIDOR

210A

STAIR 2

FWS

OPEN

OFFICE

MENS

RESTROOM

WOMENS

RESTROOM

SMALL

CONFERENCE

ROOM

BREAK

ROOM

STORAGE

NIZ

OPEN

OFFICE

DN

RANDOM

A9.6

A9.6

A9.6

WD - 1WD - 1

CPT - 2

CPT - 1

CPT-3 BROADLOOM TO MATCH

CARPET TILE ELSEWHERE

CPT - 3

ELEV

CPT - 3

CPT - 3

A9.6

A9.6

FT - 2

FLOOR TILE

RF - 1

RESILIENT FLOORING

CPT - 1

24x24 CARPET TILE

CPT - 2

24x24 CARPET TILE

WD - 1

WOOD STAIR TREADS

CARPET TILE PATTERN: RANDOM

CARPET TILE PATTERN: LINEAR

RANDOM

CPT - 3

24x24 CARPET TILE, WALK OFF (BROADLOOM

TO MATCH CARPET TILE AT STAIR 2)

FLOOR FINISH MATERIALS LEGEND 0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 3:

P

M

A2.2F

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

SECOND LEVEL FLOOR FINISH PLAN

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

BP

BP

: 1/8" = 1'-0"A2.2FA2.2F

9 SECOND LEVEL FLOOR FINISH PLAN

DN

B

C

A A

C C

E E

D D

A5.0

A5.0

A5.1

A5.1

B B

LIGHTWELL, OPEN TO BELOW

W3

A8.1

A5.1

A5.1

A5.0

A5.0

A5.4

A5.2

A5.3

A5.2

A5.2

OPEN ATTIC SPACE

OPEN ATTIC SPACE

ATTIC

ELEV. SHAFT.

A8.2

12' - 0 3/4" 3' - 6 3/4" 8' - 4 3/4" 18' - 4 1/2" 7' - 8 1/4" 2' - 0"

MECH.

4'

/4

7'

/2

1'

/4

C

LE

A R

M

IN

W3

OPEN ATTIC SPACE

/4

6'

/2

18' - 4 1/2"

301.1

303.1

7'

PAINTED PLYWOOD

FLOOR, TYP.

4'

/4

.1

6"

RED LINE

REPRESENTS 1HR

RATING ENCLOSURE

RED LINE REPRESENTS

1HR RATING ENCLOSURE

124' - 6"

INSULATE PERIMETER WALLS

OF ENCLOSED ATTIC SPACES,

SEE SECTIONS.

INSULATE PERIMETER WALLS

OF ENCLOSED ATTIC SPACES

A5.2

1/ 4"

8'

11' - 9 1/4" 3' - 6 3/4" 8' - 5 1/4" 18' - 3 3/4"

W3

W3

W3

W3

2' - 10 3/4"

3' - 0"

3'

W3

1. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES

OR CONFLICTS PRIOR TO COMMENCING WORK.

2. FIELD VERIFY ALL DIMENSIONS. DO NO SCALE DRAWINGS.

THE CONTRACTOR SHALL NOTIFY THE ARCHITECT

IMMEDIATELY OF ANY DISCREPANCIES BETWEEN EXISTING

CONDITIONS AND THE CONTRACT DOCUMENTS PRIOR TO

COMMENCING WORK.

3. NEW FINISHES AND MATERIALS ADJOINING EXISTING

FINISHES AND MATERIALS SHALL BE PROPERLY INTEGRATED

TO ENSURE A UNIFORM APPEARANCE AND SEAMLESS

TRANSITION. NEW SURFACES SHALL ALIGN WITH EXISTING

ADJACENT SURFACES UNLESS NOTED OTHERWISE.

4. COORDINATE MILLWORK INSTALLATION AND PROVIDE

BLOCKING IN PARTITIONS AS REQUIRED FOR SUPPORT OR

BLOCKING FOR SUCH MILLWORK.

5. ALL GRIDLINES AND DIMENSIONS ARE FROM FACE OF

STUD, CENTER OF COLUMN, OR FOUNDATION UNLESS NOTED

OTHERWISE.

6. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS

OF RENOVATION/EXPANSION.

7. PROVIDE A SMOOTH, LEVEL, FINISH FLOOR, TYP. PATCH

AND REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.

8. PATCH AND REPAIR ANY/ALL EXISTING WALL SURFACES AS

REQUIRED TO PROVIDE A SUITABLE SUBSTRATE FOR NEW

FINISHES.

GENERAL NOTESKEYNOTES - ATTIC LEVEL

1. DASHED LINE INDICATES ROOF HATCH ABOVE, SEE ROOF

PLAN

2. UTILITY CHASE (MECHANICAL, ELECTRICAL, ETC.)

3. PAINTED STEEL LADDER TO ACCESS ROOF HATCH.

4. TUBULAR SKYLIGHT LOCATION, SEE DETAIL

5. WRAP TUBULAR SKYLIGHT WITH INSULATION PER MANUF.

RECOMMENDATIONS

KEYNOTE IS DESIGNATED WITH THIS SYMBOL#

/12 A2.6

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 3:

P

M

A2.3

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

ATTIC LEVEL PLAN

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

BP

BP

: 1/8" = 1'-0"A2.3A2.3

9 ATTIC LEVEL

A A

C C

E E

D D

A5.0

A5.0

A4.1

A4.1 9

A4.2

A5.1

A5.1

B B

A5.1

A5.1

A5.0

A5.0

4'

/4

A5.2

A5.2

8" / 12" 8" / 12"

3"

2"

3"

2"

RIDGE

R

ID

G E

R

ID

G E

RIDGE

GENERAL ROOF NOTES:

- SEE A2.5 FOR CANOPY ROOF PLANS

- ENTIRE ROOF AREA TO RECEIVE ICE & WATER SHIELD

4" / 12"4" / 12"

6"

2"

4" / 12"

4"

2"

4"

2"

4" / 12"

4" / 12"

6"

2"

3"

2"

3"

2"

6" / 12" 6" / 12"

6"

2"

6"

2"

6" / 12"6" / 12"

6"

2"

6"

2"

6" / 12"

12' - 0"

12' - 0"

12' - 0"

8' - 0"

9'

9'

12' - 0"

8' - 0"

12' - 0"

12' - 0"

12' - 0"

12' - 0"

8'

12' - 0"

8' - 0"

8'

8' - 0"

8'

8' - 0"

8'

C U

T V

E N

T S

U

P P

E R

/2

O N

LY

E Q

E Q

EQ

CUT VENTS @ UPPER 1/2 ONLY

EQ

E Q

C U

T V

E N

T S

U

P P

E R

/2

O N

LY

E Q

C U

T V

E N

T S

U

P P

E R

/2

O N

LY

E Q

E Q

E Q

C U

T V

E N

T S

U

P P

E R

/2

O N

LY

E Q

EQ

CUT VENTS @ UPPER 1/2 ONLY

EQ

4' - 0" 6' - 0"

4'

4'

4'

4'

4'

4'

4'

4'

4'

2'

8'

6'

2'

6'

2'

8'

6' - 0" 2' - 0" 4' - 0"

4' - 0" 4' - 0" 4' - 0" 6' - 0"

A2.6

A2.6

A2.6

A2.6

1. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES

OR CONFLICTS PRIOR TO COMMENCING WORK.

2. FIELD VERIFY ALL DIMENSIONS. DO NO SCALE DRAWINGS.

THE CONTRACTOR SHALL NOTIFY THE ARCHITECT

IMMEDIATELY OF ANY DISCREPANCIES BETWEEN EXISTING

CONDITIONS AND THE CONTRACT DOCUMENTS PRIOR TO

COMMENCING WORK.

3. NEW FINISHES AND MATERIALS ADJOINING EXISTING

FINISHES AND MATERIALS SHALL BE PROPERLY INTEGRATED

TO ENSURE A UNIFORM APPEARANCE AND SEAMLESS

TRANSITION. NEW SURFACES SHALL ALIGN WITH EXISTING

ADJACENT SURFACES UNLESS NOTED OTHERWISE.

4. COORDINATE MILLWORK INSTALLATION AND PROVIDE

BLOCKING IN PARTITIONS AS REQUIRED FOR SUPPORT OR

BLOCKING FOR SUCH MILLWORK.

5. ALL GRIDLINES AND DIMENSIONS ARE FROM FACE OF

STUD, CENTER OF COLUMN, OR FOUNDATION UNLESS NOTED

OTHERWISE.

6. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS

OF RENOVATION/EXPANSION.

7. PROVIDE A SMOOTH, LEVEL, FINISH FLOOR, TYP. PATCH

AND REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.

8. PATCH AND REPAIR ANY/ALL EXISTING WALL SURFACES AS

REQUIRED TO PROVIDE A SUITABLE SUBSTRATE FOR NEW

FINISHES.

GENERAL NOTESKEYNOTES - ROOF LEVEL

1. ASPHALT SHINGLE VALLEY, REF.

2. CRICKET, OVERBUILD

3. PREFINISHED METAL DRIP EDGE, TYP. SEE DETAILS.

4. MECHANICAL INTAKE AND EXHAUST LOUVERS MOUNTED ON

SIDEWALL OF SKYLIGHT ROOF MONITOR.

5. RIDGEVENT, CONTINUOUS, REF.

6. MEMBRANE ROOFING, EPDM

KEYNOTE IS DESIGNATED WITH THIS SYMBOL#

/3 A2.6

/4 A2.6

GENERAL ROOF NOTES:

- SEE A2.5 FOR CANOPY ROOF PLANS

- ENTIRE ROOF AREA TO RECEIVE ICE & WATER SHIELD

MANUFACTURED SKYLIGHT WITH CURB, PITCHED SLOPE.

BASIS OF DESIGN: VELLUX 5X8

MANUFACTURED ROOF HATCH WITH PULL DOWN SHIP'S

LADDER w/ FOLDING ALUMINUM GUARDRAIL SYSTEM (USED

FOR CONVENIENCE AND EGRESS OUT OF MECHANICAL).

BASIS OF DESIGN: PRECISION LADDERS INC. FOLDING

ALUMINUM GUARDRAIL SYSTEM

ROOF PLAN LEGEND

ASPHALT SHINGLES (SOLAR REFLECTIVE).

BASIS OF DESIGN - MANUF/MODEL: MALARKEY ROOFING

PRODUCTS/ECOASIS PREMIUM COLOR - AGAVE

TUBULAR SKYLIGHT.

BASIS OF DESIGN: VELLUX TCC_022 TUBULAR SKYLIGHT

INDICATES AREAS OF ENCLOSED ATTIC SPACE, WITHIN

ROOF TRUSSES, THAT REQUIRE VENTING BAFFLES AND

INSULATION, AS PER DETAILS ON A2.6.

ROOF INTAKE / EXHAUST VENTING LEGEND

SHINGLE-OVER INTAKE ROOF VENT SYSTEM: CONTINUOUS EVERYWHERE

INDICATED, REGARDLESS OF EXTENT OF VENT-CUTS IN THE SHEATHING BENEATH

BASIS OF DESIGN - MANUF/MODEL: GAF - COBRA INTAKE PRO (9 IN² / L.F. NFVA)

BLUE DOTTED LINE: INDICATES EXTENT OF CUTS THROUGH

SHEATHING, DIRECTLY UNDERNEATH VENTING SYSTEM. FOLLOW

ALL MFGR'S INSTRUCTIONS FOR PREPARATION & INSTALLATION.

SHINGLE-OVER EXHAUST HIP VENT SYSTEM: CONTINUOUS EVERYWHERE

INDICATED, REGARDLESS OF EXTENT OF VENT-CUTS IN THE SHEATHING BENEATH

BASIS OF DESIGN - MANUF/MODEL: GAF - COBRA HIP VENT (9 IN² / L.F. NFVA)

ORANGE DASHED LINE: INDICATES EXTENT OF CUTS THROUGH

SHEATHING, DIRECTLY UNDERNEATH VENTING SYSTEM. FOLLOW

ALL MFGR'S INSTRUCTIONS FOR PREPARATION & INSTALLATION.

SHINGLE-OVER EXHAUST RIDGE VENT SYSTEM: CONTINUOUS EVERYWHERE

INDICATED, REGARDLESS OF EXTENT OF VENT-CUTS IN THE SHEATHING BENEATH

BASIS OF DESIGN - MANUF/MODEL: COR-A-VENT - V600T (20 IN² / L.F. NFVA)

YELLOW SOLID LINE: INDICATES EXTENT OF CUTS THROUGH

SHEATHING, DIRECTLY UNDERNEATH VENTING SYSTEM. FOLLOW

ALL MFGR'S INSTRUCTIONS FOR PREPARATION & INSTALLATION.

ENCLOSED HOOD EXHAUST VENT LOUVER: METAL, GRANULE-COATED &

FINISHED TO MATCH ROOF. SUBMIT SAMPLE TO ARCHITECT FOR APPROVAL.

FOLLOW ALL MFGR'S INSTRUCTIONS FOR PREPARATION & INSTALLATION.

BASIS OF DESIGN - MANUF/MODEL: GAF - MASTERFLOW - SSB960GWF (60 IN²

NFVA)

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 3:

P

M

A2.4

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

ROOF PLAN - MAIN

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

BP,JM

BP,JM

: 1/8" = 1'-0"A2.4A2.4

9 ROOF PLAN

B

A5.3

EPDM ROOFING

PREFINISHED

METAL DRIP EDGE

INTERIOR

EXTERIOR

RAIN DIVERTER, TO

MATCH MEMBRANE

A5.0

12' - 0" 28' - 0"

1/4" / 12"

1/ 4"

2"

1/4" / 12"

2' - 3" 21' - 0"

63' - 3"

A2.6

C

E

D

A5.4

EPDM ROOFING

STAIR 2

PREFINISHED

METAL DRIP

EDGE

ROOF DRAIN

SCUPPER

ROOF DRAIN

SCUPPER

TYP.

1/4" / 12"

1/2" / 1 2"

1/2" / 12"

22' - 0"

A5.0

1/4" / 12"

1/2" / 12"

1/2" / 12"

A5.5

A5.5

TYP.

1/4" / 12"

1/4" / 12"

1"

2"

3/ 4"

2"

1/4" / 12"

6' - 4"

28' - 4"

5'

8'

/4

1'

E X

T E

R

IO

R

I N T

E R

IO

R

RAIN DIVERTER, TO

MATCH MEMBRANE

A2.6

E

EPDM ROOFING

INTERIOR

EXTERIOR

4'

A9.3

A5.0

22' - 7 1/2"

3/ 4"

2"

1/4" / 12" 1/4" / 12"

2' - 8 1/2"

RAIN DIVERTER, TO

MATCH MEMBRANE

A

C

B

EPDM ROOFING

INTERIOREXTERIOR

EPDM ROOFING

4'

1/8" / 12"

1/4" / 12"

1/ 4"

2 " 1/

4"

2"

A5.5

ROOF DRAIN SCUPPER

ROOF OVERFLOW

DRAIN SCUPPER @ 2"

ABOVE RD SCUPPER

TYP.

1/8" / 12"

7' - 2 1/4"

4'

4' - 7"

26' - 11"

4' - 3"

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 3:

P

M

A2.5

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

ROOF PLAN - CANOPIES

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

BP,JM,JC

BP

: 1/8" = 1'-0"A2.5A4.1

5 ENTRY ROOF PLAN - NORTH

: 1/8" = 1'-0"A2.5A4.1

8 ENTRY ROOF PLAN - EAST

: 1/8" = 1'-0"A2.5A4.1

14 ENTRY ROOF PLAN - SOUTH

: 1/8" = 1'-0"A2.5A4.1

7 ENTRY ROOF PLAN - WEST

4"

CL

SHINGLE-OVER RIDGE VENT, w/

SNOW INFILTRATION FILTER.

PROVIDE 20 SQ INCHES OF VENT

AREA PER FOOT, INSTALL PER

MANUFACTURER'S SPEC

BLOCKING

6"

LAP ICE & WATER SHIELD

OVER UNDERLAYMENT, TYP.

ICE & WATER SHIELD. INSTALL 18"

EA. SIDE OF RIDGE AND PER

MFGR. RECOMMENDATIONS, TYP.

ASPHALT COMPOSITE RIDGE

SHINGLE, LAP PER MFGR.

RECOMMENDATIONS

ICE & WATER SHIELD, TYP.

1' - 6" MIN

ASPHALT SHINGLES (AS)

REF 11/A5.3

IC

E

W

A T

E R

S H

IE

LD

1'

M

IN

ICE & WATER SHIELD

3' - 0

" M

IN

FLEXIBLE MEMBRANE FLASHING WITH

12" WALL LAP. INSTALL UNDER METAL

FLASHING & SHT METAL SADDLE.

CRICKET

BLOCKING/LEDGER, AS REQUIRED

2" VENT HOLE

ICE & WATER SHIELD

SIDING SYSTEM, REF. ELEVATIONS

SHT METAL SADDLE,

EXTEND 24" MIN FROM WALL

WALL FLASHING

AIR BARRIER, LAP OVER FLASHING

8" M

IN

8" MIN

ASPHALT SHINGLES (AS)

REF 11/A5.3

ASPHALT SHINGLES (AS)

REF 11/A5.3

6" M

IN

TRANSITION FLASHING

3/4" CLOSED HEM

1/2" CLOSED HEM

ROOF FRAMING & SHEATHING,

REF. SEE STRUCTURAL

COMPOSITE SHINGLES

GASKETED WD SCREW @ 12" O.C.

GASKETED WD SCREW @ 12" O.C.

ICE & WATER SHIELD, INSTALL MIN. 18"

EACH SIDE OF TRANSITION

6" MIN

6" MIN

ICE & WATER SHIELD

UNDERLAYMENT, INSTALL

MIN. 24" EA. SIDE OF

PENETRATION & RUN UP

VENT AS SHOWN, TYP.

SKYLIGHT ASSEMBLY,

REF. SPECIFICATIONS

TRUSS BEYOND

MTL FLASHING

DOUBLE 2X BLOCKING,

AROUND ENTIRE OPENING

ASPHALT SHINGLES (AS)

REF 11/A5.3

SKYLIGHT CURB & CAP

PROVIDED BY MFGR.

ROOF CRICKET (BEYOND),

FULL WIDTH UPSLOPE OF

SKYLIGHT CURB BASE.

6" M

IN

CRICKET RIDGE

MTL. SLEEVE & CAP, PAINT TO MATCH ROOF

PRE-FORMED VENT STACK BOOT AND

CLAMP. INSTALL PER MFR'S

INSTRUCTION, COORDINATE SIZE - TYP.

PAINT TO MATCH ROOF

ICE & WATER SHIELD UNDERLAYMENT,

INSTALL MIN. 24" EA. SIDE OF PENETRATION

& RUN UP VENT AS SHOWN, TYP.

ROOF VENT

PENETRATION

T Y

P

3" M

IN

ASPHALT SHINGLES (AS)

REF 11/A5.3

ICE & WATER SHIELD, EACH SIDE

1' - 6" MIN

VALLEY FLASHING1' - 6

" M

IN

ASPHALT SHINGLES (AS)

REF 11/A5.3

MTL. CLIP, (APPROX. 2" WIDE), BEND CLIP BACK

OVER TO COVER FASTENER HEAD, TYP.

ASPHALT COMPL SHINGLES, PROVIDE DOUBLE COURSE @

VALLEY, TYP. INSTALL PER MFGR. RECOMMENDATIONS

ICE & WATER SHIELD UNDERLAYMENT,

INSTALL MIN. 18" EA. SIDE OF VALLEY

GALVANIZED METAL

VALLEY FLASHING

LAPPED VALLEY SHINGLES

LAP UNDERLAYMENT OVER ICE & WATER SHIELD MIN. 6"

CL

2X4 BLOCKING

1/2" COVER BOARD

ROOF MEMBRANE

INSULATED GLASS PANE

CONTINUOUS STEEL

TUBE, REF. STRUCTURAL

LOW SLOPE MEMBRANE ROOF

REF. 11/A5.3

SKYLIGHT ASS'Y REF. SPECS

TRUSS BEYOND

MTL FLASHING

CORNER BEAD

RO

PANEL

DIM

GYP. WALL BOARD

ROOFING, AS PER ROOF PLAN

REF. 11/A5.3 FOR ASSEMBLY INFO

S

TR

'L R

E F.

(FU

R

R

IN

G

2x S

TU

D

M

IN

. 14"

BATT INSULATION, MIN. R-49

GYP. WALL BD. & FINISH,

AS SCHEDULED

2" BAFFLES, FULL

WIDTH OF EVERY

STUD BAY, TYP.

B.O. TOP CHORD

GIRDER TRUSS

S P

R A

Y F

O A

M

IN

S U

L

B A

T T

IN

S

U L

S

P F

S T

R 'L

R E

F

F U

R R

IN

G

1/

2"

SPRAY FOAM ENTIRE LIGHTWELL

/ MONITOR ROOF CAVITY, AND

WALL CAVITY DOWN TO B.O. TOP

CHORD OF ADJ, ROOF TRUSS

A2.6

14 SIM

A9.3

6 SIM

A2.6

ASPHALT SHINGLES (AS)

REF. 11/A5.3

FLASHING, PRE-FINISHED TO MATCH FASCIA

3/4" CLOSED HEM

1/2" CLOSED HEM

ROOF FRAMING & SHEATHING,

REF. SEE STRUCTURAL

GASKETED WD SCREW @ 12" O.C.

GASKETED WD SCREW @ 12" O.C.

ICE & WATER SHIELD, INSTALL MIN. 12" VERT.

UP WALL & MIN. 36" DOWN RAKE OF ROOF.

6" V

E R

T . M

IN

F

LA

S H

IN

G

V E

R T

. M

IN

IC

E W

A T

E R

S H

IE

LD

) O V

E R

LA

P

3" M

IN

8" MIN.

LAP VAPOR BARRIER OVER ICE & WATER

SHIELD, MIN. 3"

FIBER CEMENT SHINGLES (FS2)

REF. 11/A5.2

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 3:

P

M

A2.6

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

ROOF DETAILS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

JM

JM

: 1 1/2" = 1'-0"A2.6A2.4

3 RIDGE VENT

: 3" = 1'-0"A2.6

11 ROOF TO WALL, w/ CRICKET

: 3" = 1'-0"A2.6

15 ROOF TRANSITION AT PITCH BREAK

: 3" = 1'-0"A2.6A2.4

12 SKYLIGHT TUBE/DOME - CURB @ ROOF & CRICKET

: 1 1/2" = 1'-0"A2.6

2 PIPE VENT / ROOF PENETRATION, TYP.

: 1 1/2" = 1'-0"A2.6A2.4

4 VALLEY @SHINGLE ROOFING

: 3" = 1'-0"A2.6A2.5

9 ROOF RAIN DIVERTER

: 3" = 1'-0"A2.6A2.4

14 MONITOR SKYLIGHT CURB DETAIL

: 1" = 1'-0"A2.6A5.0

10 BAFFLES & ATTIC INSULATION

: 1 1/2" = 1'-0"A2.6A5.0

5 ROOF @ MONITOR & SKYLIGHT

: 3" = 1'-0"A2.6A2.6

13 ROOF @ MONITOR WALL

B

C

R E

F

C

MENS

PUBLIC

RESTROOM

WOMENS

PUBLIC

RESTROOM

ELEC.

CLOS.

ELEV.

19' - 6" 8' - 6"

/4

2'

/4

6'

/4

3'

/2

2' - 5 1/4" 8' - 0 3/4" 6' - 11 3/4" 2' - 0 1/4" 8' - 2 1/2"

A8.2

8DF

UTILITY CHASE

60" DIA.

8' - 3"

3'

6'

/4

"X

C

LE

A R

A R

E A

"X

C

LE

A R

A R

E A

60" DIA.

1'

2'

3'

/4

3'

5'

1'

W E

T W

A

LL

WHU

WHT WHT

WHS WHS

UMS

TA-1

TA-10TA-10

WHT

WHT

3'

T Y

P

WHT

TA-1

TA-8

TA-8TA-8

TA-8 TA-8

TA-6 TA-6

TA-6TA-6

3" TYP.

5' - 0" TYP.

TA-3TA-3

TPA

TA-13

TA-9

TA-2 TA-2TA-9

TA-13

TA-4,

TA-5

TA-4

TA-4 TA-4, TA-5

TA-4, TA-5

E

D

MENS

RESTROOM

WOMENS

RESTROOM

BREAKROOM

SMALL

CONFERENCE

ROOM /

LACTATION

1'

8'

1 3/4"

12' - 0" 5' - 6" 2' - 5" 6' - 0 1/2" 13' - 10 1/2" 2"

5'

/2

2'

2'

1'

2'

3'

/4

1'

/2

4'

2' - 5" 2' - 0" 3' - 7"

7'

5'

/4

4' - 7"

4' - 7"

P-LAM COUNTERTOP, SUPPORTED WITH

HEAVY-DUTY METAL BRACKET AND

WOOD LEDGER, SEE DETAILS.

P-LAM COUNTERTOP,

TYPICAL IN BREAKROOMS

VENDING MACHINE O.P.O.I.

REFRIGERATOR, O.P.O.I.

60" DIA.

30"X48"

54"X78"

30"X48"

30"X48"

M

IN

C

LE

A R

M

IN

3'

TA-2 TA-1

60" DIA. CLEAR

5' - 6 1/2"

5'

/4

"IMPORTANT NOTE: SECOND LEVEL

RESTROOMS 235 AND 236 AND BREAKROOM

234 ARE THE IDENTICAL IN LAYOUT WITH THE

EXCEPTION OF THE LENGTH OF THE L-SHAPED

COUNTER IN 236. THIS IS NOTED ON A2.1.

5' - 5 3/4"

WET WALL

TA-3

TA-4

TA-5

TA-8

5' - 2 3/4" 3' - 3" 3' - 3 1/2"

9'

3/ 4"

3"

UMS

WHU

WHTWHT

TPA

2'

DF

TA-9

/4

2' - 0"

A6.8 2

A6.8 7

TA-2 TA-1

TA-4

TA-5

TA-4

TA-5

UMSTA-13

TA-13

TA-8

A

B

MAIL

ROOM

103A

RECEPTION

LOBBY

MEDIUM

CONFERENCE

ROOM

ENTRY

VEST.

13' - 7 1/4"

/2

1' - 9 1/2" 1' - 0" 16' - 1 1/2" 1' - 2" 19' - 1 1/4"

5' - 2"

3'

/2

/2

2'

/4

5'

/2

4'

1/ 2"

5'

/4

INFO BOARD, REF:

WOOD FEATURE

WALL, REF:

OPERABLE PARTITION

WALL STORAGE CAVITY.

CONTRACTOR TO VERIFY

CRITICAL DIMENSIONS WITH

MANUFACTURER REQUIRED

CLEARANCES.

PLASTIC-LAMINATE

CASEWORK, TYP.

REF:

2' - 0" TYP.

10' - 9 1/2"

3/

4"

/4

3'

3 1/2"

1' - 2"1' - 8 3/4"

2' - 6"

16' - 0" 23' - 9 1/4"

MAIL SLOTS, REF:

4' - 5 3/4"

4'

/4

5'

/2

2'

2'

4'

1/ 4"

CONTRACTOR TO VERIFY

DIMENSIONS WITH MANUF.

3' - 10 1/2"

/9 A6.1

CUSTOM RECEPTION

DESK, SEE /7 A6.1

WALL GRAPHIC,

SEE /3 A6.3

/12 A9.7MAP STORAGE, REF:

LAMINATE CASEWORK, REF: /11 A6.2

STONE FINISH,

REF: /10 A6.2

6' - 2"

/9 A6.1

5'

/4

6'

/4 A6.2

/7 A6.2

5' - 3 1/2" 8' - 7 1/2"

WALK OFF MATT, REF: /8 A5.5

1' - 4 1/4"1' - 8"

(6) ROWS OF 18 CHAIRS = 108 TOTAL

POSSIBLE OR (2) GROUPS OF 54.

FE&E NOT PROVIDED IN THIS

CONTRACT.

PROJECTION SCREEN

CALCULATION:

-ASPECT RATIO OF 4:3, ASSUMED

-MAX DISTANCE AWAY FROM

SCREEN IS 31 FT

-1/4 TO 1/6 RATIO FOR SCREEN

HEIGHT, ASSUMED.

-THEN, SCREEN HEIGHT SHALL BE

BETWEEN 7.75' FT BASED 1:4 AND

5.2 FT BASED ON 1:6 (FROM

DRAPER.COM, PROJECTION

SCREEN CALCULATIONS)

* GC TO VERIFY THIS DESIGN WITH

C.O. DURING CONSTRUCTION.

ASSUMED CTR. OF

PROJ. SCREEN

30' - 3"

28' - 6

ASSUMED CTR. OF

PROJ. SCREEN

28' - 2"

30' - 4"

CHAIRS ARE NOT IN CONTRACT

7'

1"

6'

LARGE

MEETING

ROOM

NOTE: REF:

FOR PROJECTOR SPECIFICATIONS

/11 A7.1

TPA = TOILET PARTITION METAL

WHT = WALL HUNG TOILET CERAMIC

WHS = WALL HUNG SINK CERAMIC

UMS = UNDERMOUNT SINK SOLID SURFACE

HD = HAND DRYER STAINLESS STEEL

SD = SOAD DISPENSER STAINLESS STEEL

TP = TOILET PAPER DISPENSER STAINLESS STEEL

TD = TOWEL DISPENSER RECEPTACLE, SEMI-RECESSED STAINLESS STEEL

CT = CHANGING TABLE, WALL HUNG RECESSED, STAINLESS STEEL

DF = DRINKING FOUNTAIN SEE PLUMBING DRAWINGS

MS = MOP SINK SEE PLUMBING DRAWINGS

FIXTURES LEGEND

TOILET ACCESSORIES

TA-1 = WASTE RECEPTACLE W/ PAPER TOWEL DISPENSER

TA-2 = WARM-AIR ELECTRIC DRYERS

TA-3 = FOAMING-SOAP DISPENSER

TA-4 = TOILET TISSUE DISPENSER

TA-5 = SANITARY NAPKIN DISPOSAL UNIT

TA-6 = HORIZONTAL GRAB BAR, 36" LONG

TA-7 = VERTICAL GRAB BAR, 18" LONG

TA-8 = SEAT-COVER DISPENSER

TA-9 = MIRROR UNIT - SIZE PER ELEVATION

TA-10 = DIAPER-CHANGING STATION

TA-11 = UNDERLAVATORY GUARD

TA-12 = not used

TA-13 = TOILET PARTITION HOOKS, STAINLESS STEEL (TYP. EVERY STALL)

TA-14 = MOP & BROOM HOLDER

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 3:

P

M

A3.0

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

ENLARGED FLOOR PLANS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

BP

BP

: 1/4" = 1'-0"A3.0A2.1

3 PUBLIC RESTROOMS

: 1/4" = 1'-0"A3.0A2.1

5 STAFF RESTROOMS, BREAKROOM & SM. CONF

: 1/4" = 1'-0"A3.0A2.1

13 LOBBY

: 1/8" = 1'-0"A3.0A3.0

12 LARGE MEETING ROOM 105 - FURNITURE / AV DIAGRAM

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

67 5 4 3 2 1 A5.0

A5.0

TO ROOF

139' - 10"

ATTIC LEVEL

124' - 6"

A5.1

A5.1

NSFS1 FS2 FS2 FS1 NS FS2 FS1

FS2

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W4

W4

W4

W4

W1

W1

W1

W1

W1

W1

W2

W1

W1

W1

W1

W1

W1

A5.3

A5.2

A5.2

2' - 0" 2' - 0" 2' - 0" 2' - 0"

8' - 0"8' - 0"8' - 0" 8' - 0" 8' - 0" 8' - 0" 2' - 0"

8' - 0" 8' - 0" 8' - 0" 8' - 0" 10' - 0"10' - 0" 2' - 0"

6' - 0" 8' - 0" 2' - 0"

5' - 0" 5' - 0"

8' - 0" 8' - 0"

S5

W3

127.5

W5

NSNS

A5.5

NSAS

A9.13

4' - 0"

10"

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

A C ED

A5.1

A5.1

B

TO ROOF

139' - 10"

ATTIC LEVEL

124' - 6"

A5.0

A5.0

FS1NS

FS2

FS2

FS1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

2' - 0"

14 A5.5

SIM

7' - 8"7' - 8" 7' - 8"7' - 8"7' - 8" 7' - 8" 7' - 8"7' - 8" 7' - 8"

2' - 0"2' - 0"

S6

NSAS

KEYNOTES - BUILDING ELEVATIONS

1. NOT USED

2. USFS, BLM, USFWS SHIELDS; CAST ALUMINUM

3. PRECAST CONCRETE WALL BANDING, MATCH LINTEL/SILL. EACH PIECE

4' IN LENGTH, AS SHOWN IN ELEVATION.

4. PRECAST CONCRETE BENCH SEAT, MATCH LINTEL/SILL

5. TIMBER-FRAMED WOOD SUPPORT STRUCTURE, DOUG-FIR, CLEAR FINISH

6. METAL SOFFIT AND EDGE, PREFINISHED

7. METAL CLAD WINDOW, PAINTED WOOD INTERIOR, FIBER-CEMENT

EXTERIOR TRIMWORK, TYP.

8. PRECAST CONCRETE LINTEL AND SILL, TYP.

9. STOREFRONT WINDOW SYSTEM, ALUMINUM, 2"x4.5", ANODIZED

10. SUPPORT BRACKET, DOUG FIR, CLEAR OIL FINISH

11. BIRD-NETTING AND CABLING AT UNDERSIDE OF TIMBER-FRAMED SUPPORT

STRUCTURE

12. BIRD SPIKES AT ALL KNEE-BRACE CROTCHES, AND INTERJECTIONS OF

KNEE-BRACES AND TOP OF BEAMS, TYP.

13. HOLLOW METAL EXTERIOR DOOR, TYP.

14. ROOF SCUPPER & DOWNSPOUT NOZZLE

15. ROOF SCUPPER & OVERFLOW SPOUT

KEYNOTE IS DESIGNATED WITH THIS SYMBOL#

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

AB

W5

A4.1

EXTERIOR MATERIALS LEGEND

FIBER CEMENT LAP SIDING

BASIS OF DESIGN - MANUF/MODEL: JAMES HARDIE/ARTISAN LAP SIDING & TRIM,

1 1/2" THICK, 6"W(5.5" ACTUAL), SMOOTH TEXTURE, PRIMED & FIELD PAINT,

COLOR - SW 7065 ARGOS (LIGHT GRAY)

FS1

SYMBOL DESCRIPTION

FS2

FIBER CEMENT SHINGLES

BASIS OF DESIGN - MANUF/MODEL: JAMES HARDIE/HARDISHINGLE SIDING, STAGGERED

EDGE PANEL, 1/4" THICK, 48" L, 15.25" H, 6" EXPOSURE

COLOR - SW 7067 CITYSCAPE (DARK GRAY)

NATURAL STONE

BASIS OF DESIGN - MANUF/MODEL: REGIONALLY SOURCED, CUT STONE, 2" D,

ASHLAR PATTERN, REFERENCE WALL SECTIONS & DETAILS FOR ADDL INFO, TYP.

COLOR/SPECIES - MUTUAL MATERIALS, LOON LAKE

NS

AS

ASPHALT SHINGLES (SOLAR REFLECTIVE)

BASIS OF DESIGN - MANUF/MODEL: MALARKEY ROOFING PRODUCTS/ECOASIS PREMIUM,

SRI OF 29 OR GREATER; COLOR - AGAVE; REFERENCE SPECS FOR ADDITIONAL

INFORMATION, TYPICAL

BASIS OF DESIGN IMAGE: COLOR & PATTERN REFERENCE (MUTUAL MATERIALS, LOON LAKE)

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

5 4 3

5FS1

W1

INTERAGENCY NATURAL

RESOURCE CENTER

BUILDING SIGNAGE,

PINNED

A4.1

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 3:

P

M

A4.1

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

EXTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

JM

BP

: 1/8" = 1'-0"A4.1A2.1

5 NORTH ELEVATION

: 1/8" = 1'-0"A4.1A2.1

9 WEST ELEVATION

: A4.1

11 NORTHWEST PERSPECTIVE VIEW PERSPECTIVE SHOWN FOR REFERENCE ONLY

: 1/8" = 1'-0"A4.1A2.1

8 ENTRY VESTIBULE - EAST ELEVATION

: 1/8" = 1'-0"A4.1A2.1

7 ENTRY VESTIBULE - NORTH ELEVATION

SECOND LEVEL

113' - 6"

ACE D

A5.1

A5.1

B

ATTIC LEVEL

124' - 6"

A5.0

A5.0

FS1 FS2 FS1 NS W5

FS1

W4

W4

W4

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W3

W3

3 3

2' - 0" 8' - 0" 8' - 0"

2' - 0"

8' - 0"8' - 0" 8' - 0" 8' - 0"8' - 0" 1' - 0"

W1

A5.5

NSAS

1' - 4"

6'

3'

1"

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

6 754321

A5.0

A5.0

TO ROOF

139' - 10"

ATTIC LEVEL

124' - 6"

A5.1

A5.1

A5.2

A5.2

OPERABLE WINDOWS IN

BREAK ROOM (REF. PLAN)

FS1NS FS2 FS1 FS2 FS1 FS2FS1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1

FS2

2' - 0" 8' - 0"

2' - 0"

8' - 0" 8' - 0" 8' - 0" 8' - 0" 2' - 0"

8' - 0"8' - 0"8' - 0" 2' - 0"

8' - 0" 8' - 0" 8' - 0" 8' - 0" 2' - 0"

8' - 0" 8' - 0" 8' - 0" 8' - 0"9' - 11 3/4" 10' - 0 1/4" 2' - 0" 2' - 0"

8' - 0"

5' - 0"5' - 0" 5' - 8"

NSAS

S7

A5.5

KEYNOTES - BUILDING ELEVATIONS

1. NOT USED

2. USFS, BLM, USFWS SHIELDS; CAST ALUMINUM

3. PRECAST CONCRETE WALL BANDING, MATCH LINTEL/SILL. EACH PIECE

4' IN LENGTH, AS SHOWN IN ELEVATION.

4. PRECAST CONCRETE BENCH SEAT, MATCH LINTEL/SILL

5. TIMBER-FRAMED WOOD SUPPORT STRUCTURE, DOUG-FIR, CLEAR FINISH

6. METAL SOFFIT AND EDGE, PREFINISHED

7. METAL CLAD WINDOW, PAINTED WOOD INTERIOR, FIBER-CEMENT

EXTERIOR TRIMWORK, TYP.

8. PRECAST CONCRETE LINTEL AND SILL, TYP.

9. STOREFRONT WINDOW SYSTEM, ALUMINUM, 2"x4.5", ANODIZED

10. SUPPORT BRACKET, DOUG FIR, CLEAR OIL FINISH

11. BIRD-NETTING AND CABLING AT UNDERSIDE OF TIMBER-FRAMED SUPPORT

STRUCTURE

12. BIRD SPIKES AT ALL KNEE-BRACE CROTCHES, AND INTERJECTIONS OF

KNEE-BRACES AND TOP OF BEAMS, TYP.

13. HOLLOW METAL EXTERIOR DOOR, TYP.

14. ROOF SCUPPER & DOWNSPOUT NOZZLE

15. ROOF SCUPPER & OVERFLOW SPOUT

KEYNOTE IS DESIGNATED WITH THIS SYMBOL#

EXTERIOR MATERIALS LEGEND

FIBER CEMENT LAP SIDING

BASIS OF DESIGN - MANUF/MODEL: JAMES HARDIE/ARTISAN LAP SIDING & TRIM,

1 1/2" THICK, 6"W(5.5" ACTUAL), SMOOTH TEXTURE, PRIMED & FIELD PAINT,

COLOR - SW 7065 ARGOS (LIGHT GRAY)

FS1

SYMBOL DESCRIPTION

FS2

FIBER CEMENT SHINGLES

BASIS OF DESIGN - MANUF/MODEL: JAMES HARDIE/HARDISHINGLE SIDING, STAGGERED

EDGE PANEL, 1/4" THICK, 48" L, 15.25" H, 6" EXPOSURE

COLOR - SW 7067 CITYSCAPE (DARK GRAY)

NATURAL STONE

BASIS OF DESIGN - MANUF/MODEL: REGIONALLY SOURCED, CUT STONE, 2" D,

ASHLAR PATTERN, REFERENCE WALL SECTIONS & DETAILS FOR ADDL INFO, TYP.

COLOR/SPECIES - MUTUAL MATERIALS, LOON LAKE

NS

AS

ASPHALT SHINGLES (SOLAR REFLECTIVE)

BASIS OF DESIGN - MANUF/MODEL: MALARKEY ROOFING PRODUCTS/ECOASIS PREMIUM,

SRI OF 29 OR GREATER; COLOR - AGAVE; REFERENCE SPECS FOR ADDITIONAL

INFORMATION, TYPICAL

BASIS OF DESIGN IMAGE: COLOR & PATTERN REFERENCE (MUTUAL MATERIALS, LOON LAKE) 0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 3:

P

M

A4.2

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

EXTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

JM

BP

: 1/8" = 1'-0"A4.2A1.0

9 EAST ELEVATION

: 1/8" = 1'-0"A4.2A2.1

5 SOUTH ELEVATION

: A4.2

11 SOUTHEAST PERSPECTIVE VIEW PERSPECTIVE SHOWN FOR REFERENCE ONLY

SECOND LEVEL

113' - 6"

E D

ATTIC LEVEL

124' - 6"

W1

W1

FS1

FS2

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

ED

ATTIC LEVEL

124' - 6"

W1

W1

FS2

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

E D

ATTIC LEVEL

124' - 6"

W3

W3

FS2

AS

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

ED

ATTIC LEVEL

124' - 6"

W1

W1

FS1

FS2

AS

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

ATTIC LEVEL

124' - 6"

FS1

FS1

AS

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

ATTIC LEVEL

124' - 6"

FS1

FS1

A5.5

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

A B

ATTIC LEVEL

124' - 6"

FS2

FS1 W1

AS

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

AB

ATTIC LEVEL

124' - 6"

FS2

W1

EXTERIOR MATERIALS LEGEND

FIBER CEMENT LAP SIDING

BASIS OF DESIGN - MANUF/MODEL: JAMES HARDIE/ARTISAN LAP SIDING & TRIM,

1 1/2" THICK, 6"W(5.5" ACTUAL), SMOOTH TEXTURE, PRIMED & FIELD PAINT,

COLOR - SW 7065 ARGOS (LIGHT GRAY)

FS1

SYMBOL DESCRIPTION

FS2

FIBER CEMENT SHINGLES

BASIS OF DESIGN - MANUF/MODEL: JAMES HARDIE/HARDISHINGLE SIDING, STAGGERED

EDGE PANEL, 1/4" THICK, 48" L, 15.25" H, 6" EXPOSURE

COLOR - SW 7067 CITYSCAPE (DARK GRAY)

NATURAL STONE

BASIS OF DESIGN - MANUF/MODEL: REGIONALLY SOURCED, CUT STONE, 2" D,

ASHLAR PATTERN, REFERENCE WALL SECTIONS & DETAILS FOR ADDL INFO, TYP.

COLOR/SPECIES - MUTUAL MATERIALS, LOON LAKE

NS

AS

ASPHALT SHINGLES (SOLAR REFLECTIVE)

BASIS OF DESIGN - MANUF/MODEL: MALARKEY ROOFING PRODUCTS/ECOASIS PREMIUM,

SRI OF 29 OR GREATER; COLOR - AGAVE; REFERENCE SPECS FOR ADDITIONAL

INFORMATION, TYPICAL

BASIS OF DESIGN IMAGE: COLOR & PATTERN REFERENCE (MUTUAL MATERIALS, LOON LAKE) KEYNOTES - BUILDING ELEVATIONS

1. NOT USED

2. USFS, BLM, USFWS SHIELDS; CAST ALUMINUM

3. PRECAST CONCRETE WALL BANDING, MATCH LINTEL/SILL. EACH PIECE

4' IN LENGTH, AS SHOWN IN ELEVATION.

4. PRECAST CONCRETE BENCH SEAT, MATCH LINTEL/SILL

5. TIMBER-FRAMED WOOD SUPPORT STRUCTURE, DOUG-FIR, CLEAR FINISH

6. METAL SOFFIT AND EDGE, PREFINISHED

7. METAL CLAD WINDOW, PAINTED WOOD INTERIOR, FIBER-CEMENT

EXTERIOR TRIMWORK, TYP.

8. PRECAST CONCRETE LINTEL AND SILL, TYP.

9. STOREFRONT WINDOW SYSTEM, ALUMINUM, 2"x4.5", ANODIZED

10. SUPPORT BRACKET, DOUG FIR, CLEAR OIL FINISH

11. BIRD-NETTING AND CABLING AT UNDERSIDE OF TIMBER-FRAMED SUPPORT

STRUCTURE

12. BIRD SPIKES AT ALL KNEE-BRACE CROTCHES, AND INTERJECTIONS OF

KNEE-BRACES AND TOP OF BEAMS, TYP.

13. HOLLOW METAL EXTERIOR DOOR, TYP.

14. ROOF SCUPPER & DOWNSPOUT NOZZLE

15. ROOF SCUPPER & OVERFLOW SPOUT

KEYNOTE IS DESIGNATED WITH THIS SYMBOL#

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

A B

ATTIC LEVEL

124' - 6"

W1

W4

FS2

NS

AS

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

AB

ATTIC LEVEL

124' - 6"

W1

FS1

FS2

W5

AS

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A4.3

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

EXTERIOR ELEVATIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

JM

BP

: 1/8" = 1'-0"A4.3A2.1

1 EAST ELEV @ GRID 3 SOUTH

: 1/8" = 1'-0"A4.3A2.1

2 WEST ELEV - GRID 4 SOUTH

: 1/8" = 1'-0"A4.3A2.1

3 EAST ELEV - GRID 5 SOUTH

: 1/8" = 1'-0"A4.3A2.1

4 WEST ELEV - GRID 6 SOUTH

: 1/8" = 1'-0"A4.3A2.1

6 SOUTH ELEV - GRID C/D EAST

: 1/8" = 1'-0"A4.3A2.1

5 NORTH ELEV - GRID C/D EAST

: 1/8" = 1'-0"A4.3A2.2

7 WEST ELEV - GRID 4 NORTH

: 1/8" = 1'-0"A4.3A2.2

8 EAST ELEV - GRID 3 NORTH

: 1/8" = 1'-0"A4.3A2.1

9 WEST ELEV - GRID 6 NORTH

: 1/8" = 1'-0"A4.3A2.1

10 EAST ELEV - GRID 5 NORTH

SECOND LEVEL

113' - 6"

A

LOWER LEVEL

90' - 0"

CE D

A5.1

A5.1

B

ATTIC LEVEL

124' - 6"

STAIR 1

EXECUTIVE

ASSISTANT/

WAITING

RECEPTION

FOYER

LIGHTWELL

ROOF

MONITOR

A5.0

A5.0

A5.3

BREAKROOM

BREAK

ROOM

SUPERVISORS

OFFICE

CORRIDOR

113B

TEL/COMM

ATTIC ATTIC

UNEXCAVATEDUNEXCAVATED

A9.3

A5.0

A5.0

INSUL. PERIM. WALLS OF

ENCLOSED ATTIC SPACES

INSUL. PERIM. WALLS OF

ENCLOSED ATTIC SPACES

CHASE

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

LOWER LEVEL

90' - 0"

754321

A5.0

A5.0

ATTIC LEVEL

124' - 6"

A5.1

A5.1

A5.2

A5.2

ATTIC

MEDIUM

CONFERENCE

ROOM

TEC

OFFICE

VEG

OFFICE

ECO

OFFICE

SECURITY

OFFICE

STORAGE

105A

VESTIBULE/

BREAKOUT

MENS

PUBLIC

RESTROOM

WOMENS

PUBLIC

RESTROOM

ELEC.

CLOS.

BLM

OFFICE

MECHANICAL

ROOM

BUILDING

STORAGE

NEPA

PLANNER

OPEN

OFFICE

MEDIUM

CONFERENCE

ROOM

STAIR 1

BLM

OFFICE

BLM

OFFICE

CIO

OFFICE

PRIVACY

ROOM

STAIR 1

JAN.

CLOS.

VESTIBULE

TEL/COMM

MECH.

302ATTIC

LIGHTWELL

9'

ATTIC

8'

"UNEXCAVATED UNEXCAVATED

A2.6

10 SOH

A2.6

10 SOH

INSUL. PERIM.

WALLS OF

ENCLOSED

ATTIC SPACES

INSULATE PERIMETER WALLS

OF ENCLOSED ATTIC SPACES

7'

A9.7

INTERIOR WALL ASSEMBLY @ WOOD WALL

CLEAR 6" DOUG FIR VENEER T&G OVER

WOOD ADHESIVE APPLIED TO FACE OF

3/4" WOOD FURRING STRIPS OVER

5/8" TYPE "X" GWB

A2.6

2"

WW-3 ACCENT WALL 6"

WIDE PANELS

TERMINATION OF WW-3 AT

TRIM BOARD WALL REF. /5 A9.7

EQ.

WW-3

17' - 10 1/4"

6"

GAP AT SIDE TO BE

DETERMINED BY MATERIAL

@ EITHER SIDE, FIELD

VERIFY DIMENSIONS , DO

NOT RIP T&G TO FIT, ALLOW

EQ. SPACE ON EITHER SIDE

2-1/2" MAX. 2-1/2" MAX.

A9.7

/2

V

IF

6'

3'

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A5.0

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

BUILDING SECTIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

JM

BP

: 1/8" = 1'-0"A5.0A2.0

13 N/S BUILDING SECTION 1

: 1/8" = 1'-0"A5.0A2.0

6 E/W BUILDING SECTION 1

: 1/4" = 1'-0"A5.0A5.0

11 LIGHT WELL WALL SECTION

: 1/4" = 1'-0"A5.0A5.0

12 LIGHT WELL ELEVATION

SECOND LEVEL

113' - 6"

A

LOWER LEVEL

90' - 0"

CE D

A5.1

A5.1

B

ATTIC LEVEL

124' - 6"

A5.0

A5.0

BLM

OPEN

OFFICE

AQM

OPEN

OFFICE

TEC

OPEN

OFFICE

CIO

OFFICE

LAW

OFFICE

(USFS)

LAW

OFFICE

(BLM)

LAW

ENFORCEMENT

OPEN

OFFICE

A5.2

9'

ATTIC

UNEXCAVATED

INSULATE PERIMETER WALLS

OF ENCLOSED ATTIC SPACESATTIC

INSULATE PERIMETER WALLS

OF ENCLOSED ATTIC SPACES

SOUND ATTENUATION BATTS

AT ALL ACT CEILING, TYPICAL.

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

LOWER LEVEL

90' - 0"

7 5 4 3 2 1

A5.0

A5.0

ATTIC LEVEL

124' - 6"

FWS

OPEN

OFFICE

LARGE

CONFERENCE

ROOM

FWS

ASST.

STATE

SUPERINTENDENT

OFFICE

EXECUTIVE

ASSISTANT/

WAITING

SUPERVISOR

FILING

MEDIUM

CONFERENCE

ROOM

HRM

OPEN

OFFICE

TEC

OPEN

OFFICE

TEC

OPEN

OFFICE

FMO

OPEN

OFFICE

BLM

OPEN

OFFICE

BLM

OPEN

OFFICE

BLM

OPEN

OFFICE

MAIL

ROOM

103A

RECEPTION

LOBBY

LARGE

MEETING

ROOM

A5.1

A5.1

A5.2

A5.2

ATTIC ATTIC

UNEXCAVATED UNEXCAVATED

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A5.1

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

BUILDING SECTIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

JM

BP

: 1/8" = 1'-0"A5.1A2.1

13 N/S BUILDING SECTION 2

: 1/8" = 1'-0"A5.1A2.1

6 E/W BUILDING SECTION 2

SECOND LEVEL

113' - 6"

BTM OF SOFFIT/TRUSSES

124' - 0"

FWS OPEN

OFFICE

LARGE

MEETING

ROOM

NATURAL STONE (NS)

2" ADHERED STONE MASONRY VENEER OVER

MORTAR BED OVER

WIRE LATH OVER

0.4" DRAINAGE & VENTILATION MAT OVER

1" RIGID INSULATION OVER

AIR BARRIER OVER

1/2" PLYWOOD SHEATHING OVER

2X6 WOOD STUDS @ 16" O.C. W/ 3" SPRAY FOAM

2 1/2" ROCK WOOL INSULATION

5/8" TYPE 'X' GWB

A5.2

FIBER CEMENT SHINGLES (FS2)

FIBRER CEMENT SHINGLES OVER

3/4" RAINSCREEN INSULATION OVER

AIR BARRIER OVER

1/2" PLYWOOD SHEATHING OVER

2X6 WOOD STUDS @ 16" O.C. w/ 3" SPRAY FOAM

2 1/2" ROCK WOOL INSULATION

5/8" TYPE 'X' GWB

A5.5

SOUND ATTENUATION BATTS

AT ALL ACT CEILING, TYPICAL.

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

A C ED

A5.1

A5.1

B

ATTIC LEVEL

124' - 6"

A5.0

A5.0

A5.2

HRM OPEN

OFFICE

BLM OPEN

OFFICE

BLM OFFICE

BLM OFFICE

BLM OPEN

OFFICE

NIZ OFFICE

TEC OFFICE

VEG OPEN

OFFICE

INSUL. PERIM. WALLS OF

ENCLOSED ATTIC SPACES

INSUL. PERIM. WALLS OF

ENCLOSED ATTIC SPACES

A2.6

10 SOH

FIRST/GROUND LEVEL PLAN

100' - 0"

SECOND LEVEL

113' - 6"

BTM OF SOFFIT/TRUSSES

124' - 0"

D

6" MIN. GRADE CLEARANCE

SLOPE GRADE AWAY

FROM BUILDING, TYPICAL

CONCRETE FOUNDATION WALL, TYP.

REF.

FIBER CEMENT LAP SIDING (FS 1)

FIBER CEMENT LAP SIDING OVER

3/4" RAINSCREEN AIR SPACE W/

VERTICAL 1X2 FURRING @ 16" O.C. OVER

1" RIGID INSULATION OVER

AIR BARRIER OVER

1/2" PLYWOOD SHEATHING OVER

2X6 WOOD STUDS @ 16" O.C. W/ 3" SPRAY FOAM

2 1/2" ROCK WOOL INSULATION

5/8" TYPE 'X' GWB

A5.2

2" BAFFLE, FULL WIDTH

OF EVERY STUD BAY

A5.5

VEG OPEN

OFFICE

BLM OPEN

OFFICE

VARIES

SECTION PLAN

3/4" FLAT BLOCKING, IN-LINE

w/ 1x2 FURRING, DIRECTLY

BEHIND VERTICAL TIMBER,

ANCHORED TO STUD WALL

ELEVATION

LAP SIDING BUTTS TO

SIDE OF KNEE BRACE

LO

O

K O

U T

8"

4"

6"

VARIES

C L K

N E

E B

R A

C E

C L R

A F

T E

R T

A

IL

8"

C L

8" 1' - 10"CL CL

2" 1' - 0"6"

2 1/2"

2"

4" 9"

6" W

ID

E

V E

R T

IC

A

L T

IM

B

E R

4'

6'

2' - 0"

2"

4" 1/

2" 4"

2'

5"

5 1/2"

1/

2"

8"

STUD SPACING PER STRUCTURAL

VARIES

(3) 5/8" HEX LAG SCREWS, WASHERS, & WOOD

PLUGS TO MATCH TIMBER ; VERT. @ 18" O.C.

LAP SIDING BUTTS TO SIDE OF KNEE BRACE

3/4" FLAT BLOCKING, IN-LINE w/ 1x2

FURRING, DIRECTLY BEHIND VERTICAL

TIMBER, ANCHORED TO STUD

1/4" HEX SD SCREW & WASHER FASTENED

TO 2x10 BLOCKING @ 24" o.c. VERT.

(3) 3/8" HEX LAG SCREWS,

WASHERS, & WOOD PLUGS

TO MATCH TIMBER ; VERT.

@ 18" O.C.

3/8" LAG BOLT, WASHER, &

WOOD PLUG TO MATCH TIMBER

4" W

ID

E

A N

G

LE

D B

R A

C

IN

G T

IM

B

E R

3'

4'

0"

4x4 BLOCKING

1'

3' - 10 3/4"

F A

C E

O F

T R

IM

S

ID

IN

G

BIRD SPIKES AT

CROTCH, TYP.

CL

CL CL

2x10 VERTICAL BLOCKING IN STUDWALL

4x4 BLOCKING

4" LINEAR VENT w/

BUG SCREEN, CONT.

7"

GRID

TYP.

2" BAFFLE, FULL WIDTH OF

EVERY STUD BAY, TYP.12

VARIES

CL CL

3/8" LAG BOLT, WASHER, & WOOD PLUG TO MATCH TIMBER

1" x 3 1/2" FIBER CEMENT TRIM, PAINT TO MATCH LAP SIDING

4x4 BLOCKING

LAP SIDING BUTTS TO SIDE OF KNEE BRACE

1x6 T&G SOFFIT, FINISH TO MATCH TIMBER

2' - 8" 1' - 0"

4" 4"

8" 1' - 10"

3' - 10 3/4"

4" LINEAR VENT w/

BUG SCREEN, CONT.

7"

F A

C E

O F

T R

IM

S

ID

IN

G

1/ 2"

GRID

TYP.

2" BAFFLE, FULL WIDTH

OF EVERY STUD BAY, TYP.

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A5.2

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

WALL SECTIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

JM

BP

: 1/2" = 1'-0"A5.2A2.1

11 WALL SECTION

: 1/8" = 1'-0"A5.2A2.1

5 N/S BUILDING SECTION 3

: 1/2" = 1'-0"A5.2A2.1

12 WALL SECTION

: 1" = 1'-0"A5.2A4.1

14 KNEE BRACE DETAIL, TYP.

: 1" = 1'-0"A5.2A4.1

9 LOOKOUT DETAIL - SECTION, TYP.

TIMBER FASTENERS NOTE:

ALL SCREWS / BOLTS TO BE PRE-DRILLED / PILOTED PER SCREW

MFR. RECOMMENDATIONS & COUNTER-BORED TO FIT HEX

SOCKET HEAD & WASHER, AND RECEIVE WOOD PLUG.

SECOND LEVEL

113' - 6"

A

BTM OF SOFFIT/TRUSSES

124' - 0"

B

SUPERVISORS

OFFICE

RECEPTION

FIBER CEMENT LAP SIDING (FS 1)

REF 12/A5.2

FIBER CEMENT LAP SIDING (FS 1)

REF 12/A5.2

ASPHALT SHINGLES (AS)

11/A5.3 /

A5.3

A9.3

5 SIM

A5.3

11 SIM

AB

FWS ASST.

STATE

SUPERINTENDENT

OFFICE

ENTRY VEST.

LOBBY

FIBER CEMENT LAP SIDING (FS 1)

REF 12/A5.2

ASPHALT SHINGLES (AS)

SOLAR REFLECTIVE ASPHALT SHINGLES OVER

UNDERLAYMENT, REF PLANS FOR LOCATION & TYPE OVER

PLYWD ROOF SHEATHING, REF STRUCT. TYP. OVER

SHOP-FABRICATED WOOD ROOF TRUSSES W/

BLOWN-IN LOOSE-FILL ATTIC INSULATION @ BOTTOM CHORD, TYP.

SLAB ON GRADE

CONCRETE SLAB (REF STRUCT) OVER

VAPOR BARRIER, REF SPECS OVER

CRUSHED GRAVEL

SLOPE EXT. SLAB AWAY FROM BUILDING

UNEXCAVATED UNEXCAVATED

1/4" PER FOOT

TIMBER FRAMING, REF. STR'L FOR SIZE & SPACING

1'

/2

4"

WOOD POST, REF. STRUCTURAL

STONE 'BENCH' COLUMN BASE, REF. STR'L

INTERNAL LVL BEAM, TIE BACK TO BUILDING, REF. STR'L

BEAM, REF. STR'L

MTL DRIP EDGE

A5.4

A9.3

A9.3

A9.3

3' - 6"

METAL SOFFIT PANEL ASSEMBLY (MP-1)

PAINTED, VENTED ALUMINUM SOFFIT PANEL OVER

2x2 WOOD FURRING @ 16" O.C. OVER

WOOD FRAMING (REF. STRUCTURAL)

LOW SLOPE MEMBRANE ROOF

FULLY ADHERED EPDM MEMBRANE OVER

1/2" FIBERGLASS MAT FACED GYPSUM CORE COVER BOARD OVER

TAPERED INSULATION IF APPLICABLE, REF ROOF PLAN OVER

2 LAYERS OF 3" POLYISO ROOF BOARD INSULATION OVER

VAPOR BARRIER, 8 MIL. CLEAR REINFORCED & FIRE RETARDANT OVER

PLYWOOD ROOF SHEATHING, REF STRUCT.

BIRD SPIKES, AT ALL EXPOSED BEAM TOPS

WOOD LOUVER PANEL ASSEMBLY

- 1x6 WOOD LOUVERS TO MATCH TIMBERS, SANDED & SEALED

- PRE-FINISHED METAL (FLAT BLACK)

- 40 MIL SBS SELF-ADHERED WEATHER BARRIER

- 3/4" CDX PLYWOOD BACKING

1X6 SLOPED SILL-BOARD & FLASHING, CONT.

6"x8" TIMBER RIDGE BEAM, DOUG FIR

3"x4" TIMBER LOOKOUT, DOUG FIR

5 1/2"

SECTION VIEW ELEVATION VIEW

1X6 T&G SOFFIT, TO MATCH TIMBERS

O U

T S

ID

E

F A

C E

O F

W A

LL

F

R A

M

IN

G

GRID

1' - 6" 1' - 0"1' - 6"

4" 4"

1' - 0"

1' - 4"

10"

BTM OF TRUSSES

124' - 0"

ATTIC LEVEL

124' - 6"

T O

P O

F R

ID

G

E

6'

/4

6"

1' - 10"

1' - 10"

1' - 10"

3"

6"

1/

2"

4"

3"

O U

T S

ID

E

F A

C E

O F

W A

LL

F

R A

M

IN

G (B

E

LO

W

8"

9"

ALIGN T.O. RIDGE w/ INTERSECTION

OF ADJACENT ROOF.

ROOF EDGE FLASHING

VENTED SOFFIT

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A5.3

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

WALL SECTIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

JM

BP

: 1/2" = 1'-0"A5.3A5.0

9 WALL SECTION

: 1/2" = 1'-0"A5.3A2.1

11 WALL SECTION

: 3/4" = 1'-0"A5.3A4.1

13 GABLE VENT DETAIL

SECOND LEVEL

113' - 6"

ATTIC LEVEL

124' - 6"

LAW OFFICE

(USFS)

AQM OPEN

OFFICE

FIBER CEMENT LAP SIDING (FS 1)

REF 12/A5.2

FIBER CEMENT SHINGLES (FS2)

REF 11/A5.2

8' - 0"

2'

A5.4

A9.3

A5.5

A5.5

FIRST/GROUND LEVEL PLAN

100' - 0"

T/O BENCH

101'-6"

PRECAST CONCRETE BENCH TOP

CONCRETE FOUNDATION,

SEE STRUCTURAL

NATURAL STONE (NS) STUB WALL

2" ADHERED STONE MASONRY VENEER OVER

MORTAR BED OVER

WIRE LATH OVER

0.4" DRAINAGE & VENTILATION MAT OVER

1/2" PLYWOOD SHEATHING OVER

3 5/8" GALV. MTL FRAMING @ 16" O.C.

STIRRUP WITH SEAT

2' - 0"

4" CONCRETE SIDEWALK

EXPANSION JOINT AROUND BASE

6"

WOOD COLUMN BEYOND, SEE

STRUCTURAL

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A5.4

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

WALL SECTIONS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

JM

BP

: 1/2" = 1'-0"A5.4A2.1

11 WALL SECTION

: 1 1/2" = 1'-0"A5.4A1.0

10 SEAT POST BASE

SLOPE 1:24

7"

SECTIONELEVATION (FROM ROOF) ELEVATION (EXTERIOR)

7"

4" DOWNSPOUT NOZZLE,

FASTEN TO BLOCKING

MASTIC CAULK AROUND

OPENING IN SIDING

3/4" FLAT BLOCKING, IN-LINE w/ 1x2 FURRING, DIRECTLY

BEHIND DOWNSPOUT NOZZLE.

BORE TO FIT DOWNSPOUT

NOZZLE.

5"

CORNER SCUPPER

ROOF DRAIN

TOP OF WALL

116' - 1 1/4"5"

B.O. HEADER

114' - 11"

HEADER & DECK

PER STR'L

T.O. PARAPET CAP=

T.O. ADJ. WALL BANDING

116' - 3"

A5.5

T.O. DECK

115' - 4 1/2"

SHIM AS REQ'D

BY MFGR

NATURAL STONE (NS)

REF. 11/A5.2

FIBER CEMENT SHINGLES (FS2)

REF. 11/A5.2

FLASHING, w/ DRIP-EDGE, CONT.

(INSTALL VERT. LEG BEHIND INSUL. &

BUILDING WRAP). FINISH TO MATCH

FIBER CEMENT BANDING COLOR.

AIR BARRIER, LAP

OVER FLASHING

TOP OF BANDING

116' - 3"

A9.12

14 ALT. CONDITION

@ WINDOWS

1/

2" 7"

1/

2" 1/

4" 1/

4"

3/4" 2 1/2"

1 1/2"1 3/4"

2" 3"

3 1/4"

5"

1'

/2

MIN

1"

PRE-CAST WALL BANDING, TO MATCH

PRE-CAST WINDOW SILLS & HEADERS,

WHERE OCCUR. REFERENCE EXTERIOR

ELEVATIONS FOR LOCATIONS

HEAVY-DUTY, CORROSION RESISTANT "Z-

CLIPS", SPACING AS RECOMMENDED BY

MANUFACTURER. EPOXY ANCHOR TO

BACK-FACE OF PRE-CAST WALL BANDING.

1X6 FLAT BLOCKING, CONT., ANCHORED

@ EVERY OTHER STUD

3/4" X 3/4" X 1/8" STEEL ANGLE. WELDED

TO LEDGER ANGLE, ALIGN WITH KEY-

SLOT IN BOTTOM OF PRE-CAST WALL

BAND. LEAVE A "WEEP-GAP" EVERY 48".

COMPOSITE SHIM, AS REQUIRED FOR

PROPER ALIGNMENT

4" x 4" x 1/4" STEEL LEDGER ANGLE

3/8" LAG SCREW & FLAT WASHER, FASTEN TO

STUD WALL, SPACE @ EVERY-OTHER STUD.

PRE-DRILL EACH SCREW.

AT BLOCKING: SINK SCREW HEAD BELOW

DEPTH OF "Z-CLIP" CLEARANCE

M

IN1"

KEY-SLOT, TO ACCEPT VERTICAL

LEG OF ANGLE. WIDTH OF SLOT TO

BE 1/8" WIDER THAN LEG OF

ANGLE. CHAMFER @ MOUTH OF

OPENING TO EASE INSTALLATION.

SLOP HORIZ. FACE,

TO DRAIN AWAY

FROM BUILDING

SLOP HORIZ. FACE,

TO DRAIN AWAY

FROM BUILDING

1" 1"

WALK OFF GRATE RECESSED

INTO CONCRETE SLAB. SEE

FLOOR PLANS FOR SIZE.

CONCRETE SLAB,

VERIFY DEPTH WITH

STRUCTURAL DETAILS

FINISH FLOOR

2"

2" SS PERIMETER SUPPORT

DRAIN TO CRUSHED STONE

AREA BELOW SLAB

V A

R

IE

S

CRUSHED STONE

TOP OF WALL BANDING

MATCH ADJ. PARAPET CAP

1/

2"

NATURAL STONE (NS)

REF. 11/A5.2

FIBER CEMENT SHINGLES (FS2)

REF. 11/A5.2

BUILDING WRAP, LAP

OVER METAL COPING

PRE-FINISHED METAL COPING, w/ DRIP-

RETURN @ BOTTOM, CONT. (INSTALL

VERT. LEG BEHIND INSUL. & BUILDING

WRAP). PROFILE, DEPTH, AND FINISH

TO MATCH ADJ. PARAPET CAP.

METAL CLEAT, EXTEND BACK TO

SHEATHING. EXTEND VERTICAL LEG @

SHEATHING DOWN 2".

NATURAL STONE (NS)

REF. 11/A5.2

FIBER CEMENT SIDING (FS1)

REF. 12/A5.2

TYP.

16" O.C.

GAP & CAULKING, USE BACKER ROD WHERE NECESSARY

3/4" FLAT BLOCKING

1 1/2" X 3 1/2" FIBER CEMENT CORNER TRIM PIECE

1/ 2"

1/

2"

1/2" FIBERGLASS MAT

FACED GYPSUM CORE

COVER BOARD

VAPOR BARRIER

FULLY ADHERED

EPDM MEMBRANE

SELF-ADHERED SBS

MEMBRANE OVER TOP OF

WALL. LAP MIN. 3" OVER

VAPOR BARRIER @ VERTICAL

FACE OF WALL, BOTH SIDES.

PRE-FINISHED METAL COPING w/ 4" MIN. OVERLAP @ SPLICE w/ DOUBLE

BEAD OF MASTIC. INSTALL 6" SUB-

FLASHING @ SPLICE

ADHEREED ROOFING MEMBRANE,

CONTINUED FROM ROOF, LAP OVER

TO OUTSIDE FACE OF CAP BLOCK

PRESSURE TREATED 2x12 CAP BLOCK, w/ SELF ADHERE WRB, FULLY

WRAPPED AROUND ALL SIDES PRIOR

TO INSTALL.

SELF-ADHERED SBS MEMBRANE

FULLY WRAP AROUND CAP BLOCK

PRIOR TO INSTALL.

METAL CLEAT, EXTEND BACK TO

SHEATHING. EXTEND VERTICAL LEG @

SHEATHING DOWN 2".

M

IN

SELF-ADHERED SBS MEMBRANE

OVER TOP OF WALL. LAP MIN. 3"

OVER VAPOR BARRIER @ VERTICAL

FACE OF WALL, BOTH SIDES.

5"

1/ 2"

R E

F

W A

LL

B

A N

D

IN

G

A

D J.

W A

LL

E

LE

V

B

E Y

O N

D

FIBER CEMENT

SIDING (FS1)

REF. 12/A5.2

A 5.

MITER @ OUTSIDE

CORNERS

GRID

TYP.

4' - 0" o.c.

TYP.

4' - 0" o.c.

CLCL (VERIFY)

7 3/4"

COLOR-MATCH GROUT TO PRE-CAST

CONCRETE WALL BANDING

FIBER CEMENT SHINGLES (FS2) ABOVE

(REF. EXTERIOR ELEVATIONS)

FIBER CEMENT SIDING (FS1)

REF. 12/A5.2

SCRIBE

SIDING/

SHINGLES

AROUND

PROFILE OF

PRE-CAST

BANDING,

CAULK GAP

F

LA

S H

IN

G

3"

CONCRETE FOUNDATION WALL, TYP.

5/8" HARD-COAT STUCCO (COLOR TO MATCH FS1) OVER

STRUCTURAL WIRE LATH OVER

RAINSCREEN DRAINAGE MAT OVER

3" RIGID INSULATION (EXTEND T.O. FND) OVER

CONCRETE FOUNDATION, PER STRUCTURAL

EXTERIOR SIDING OR STONE

REF. EXTERIOR ELEVATIONS

TOP OF FOUNDATION

REF. STRUCTURAL

FLASHING, w/ DRIP-EDGE-RETURN

AIR BARRIER, LAP OVER FLASHING

1"

3"

EXTEND HARD-COAT STUCCO

8" BELOW GRADE, TYP.

GRADE SHOULD POSITIVELY DRAIN

AWAY FROM FOUNDATION

1 1/2" x 1 1/2" FIBER CEMENT

TRIM, TO MATCH SIDING

FIBER CEMENT SIDING / SHINGLES (FS1 / FS2)

REF. A5.2

CAULK GAP, TO MATCH SIDING

1 1/2" x 3 1/2" FIBER CEMENT

TRIM, TO MATCH SIDING

0 1 2 3 4 5 6 7 8 9 10 inches

DRAWING NO.

PKG

NO.

SHEET

OF

PROJECT NO.:

REVISIONS:

DESIGNED

TECH. REVIEW

CADD

DESIGNED SUB SHEET NO. TITLE OF SHEET

06.01.2018

5/

/2

:1 4:

P

M

A5.5

06.01.18C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

EXTERIOR DETAILS

13083

INRC OFFICE BUILDING - PHASE 3

USDA FOREST SERVICE

JB

JM

BP

: 1 1/2" = 1'-0"A5.5A2.5

1 ROOF DRAIN SCUPPER & DOWNSPOUT NOZZLE DETAIL, TYP.

: 3" = 1'-0"A5.5A5.4

14 PRE-CAST WALL BANDING DETAIL, TYP.

: 3/4" = 1'-0"A5.5A2.1

8 RECESSED WALK OFF GRATE

: 3" = 1'-0"A5.5A4.1

12 METAL WALL BANDING DETAIL, TYP.

: 1 1/2" = 1'-0"A5.5A2.1

6 INSIDE CORNER MATERIAL TRANSITION - FS1 & NS

: 3" = 1'-0"A5.5A4.2

3 PARAPET CAP, TYP.

: 1 1/2" = 1'-0"A5.5A2.2

7 PRECAST WALL BANDING @ CORNER - PLAN LAYOUT

: 3" = 1'-0"A5.5A5.2

13 B.O. EXT. WALL @ FOUNDATION

: 1 1/2" = 1'-0"A5.5A2.1

5 SIDING @ INSIDE & OUTSIDE CORNERS - PLAN

File details come from the government source that posted it. Updated .