Drawings_Part_14_2018_06-01.pdf
PDF 1 MB Posted
- Attached to
- INRC - Phase III
- Solicitation number
- 12034318R0017
About this file
This is a pre-solicitation notice for construction of the Interagency Natural Resource Center - Phase III project in Coeur d'Alene, Idaho. The US Forest Service Northern Region anticipates awarding a contract between $5 million and $10 million to support 173 employees from the US Fish & Wildlife Service, Bureau of Land Management, and US Forest Service in a new 29,000 square foot main office building. A solicitation for proposals is expected to be posted on June 5, 2018 with responses due 30 days later.
24 - J-3 Drawings Part 14
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
16147
P R
O
FE
SS IONAL ENG INEE
RL
I C E N S ED
S T
A
T E O F I D
A H
O
A R
I AN
C . B LOOMF
I E L
D
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:3 :1
P
M
E9.9
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCHEDULES
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
RJH
BMM
ACB
Notes:
Receptacle 137880 VA 53.63% 73940 VA Total Est. Demand: 682 A
Power 123813 VA 100.00% 123813 VA Total Conn.: 841 A
Other 567 VA 100.00% 567 VA Total Est. Demand: 245588 VA
Motor 20017 VA 106.52% 21323 VA Total Conn. Load: 303033 VA
Lighting 20756 VA 125.00% 25945 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 860 A 833 A 820 A
Total Load: 102976 VA 99801 VA 98453 VA
41 0 VA 0 VA 42
39 0 VA 0 VA 40
SPARE -- 200 A 3
0 VA 0 VA
3 30 A -- SPD
35 43020... 0 VA 1 20 A -- SPARE 36
33 46480... 0 VA 1 20 A -- SPARE 34
PNL MDR
Other; Power;
Receptacle 400 A 3
49080... 0 VA 1 20 A -- SPARE 32
29 0 VA 0 VA 1 20 A -- SPARE 30
27 0 VA 0 VA 1 20 A -- SPARE 28
FUTURE ELEVATOR -- 100 A 3
0 VA 0 VA 1 20 A -- SPARE 26
23 6495 VA 0 VA 1 20 A -- SPARE 24
21 7926 VA 0 VA 1 20 A -- SPARE 22
PNL L1
Lighting; Other;
Receptacle 200 A 3
5278 VA 0 VA 1 20 A -- SPARE 20
17 1080 VA 0 VA 1 20 A -- SPARE 18
15 1080 VA 0 VA 1 20 A -- SPARE 16
PNL C1 Power; Receptacle 200 A 3
1580 VA 0 VA 1 20 A -- SPARE 14
11 47858... 0 VA 12
9 44315... 0 VA 10
PNL M1
Power; Motor;
Receptacle 200 A 3
47037... 0 VA
3 200 A -- SPARE
5 0 VA 0 VA 6
3 0 VA 0 VA 4
POWER LOGIC METER -- 30 A 3
0 VA 0 VA
3 200 A -- SPARE
CKT Circuit Description Load
Classification Trip Poles A B C Poles Trip Load
Classification Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 1000 A
Supply From: SWITCHGEAR (PHASE 1) Phases: 3 Mains Type: MLO
Location: MECHANICAL ROOM 003 Volts: 120/208 Wye A.I.C. Rating: 15,848 A
Branch Panel: MDP
Notes:
Total Est. Demand: 74 A
Total Conn.: 60 A
Receptacle 180 VA 100.00% 180 VA Total Est. Demand: 26692 VA
Other 567 VA 100.00% 567 VA Total Conn. Load: 21503 VA
Lighting 20756 VA 125.00% 25945 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 51 A 68 A 55 A
Total Load: 6096 VA 8143 VA 6580 VA
41 LTG Lighting; Other 20 A 1 909 VA 0 VA 1 20 A -- SPARE 42
39 LTG - L2 CENTER OFFICES Lighting 20 A 1 1079 VA 0 VA 1 20 A -- SPARE 40
37 LTG - L2 WAITING/CORR Lighting 20 A 1 334 VA 0 VA 1 20 A -- SPARE 38
35 LTG - L2 HALLS Lighting; Other 20 A 1 1293 VA 0 VA 1 20 A -- SPARE 36
33 LTG - L2 SOUTH Lighting; Other 20 A 1 1216 VA 0 VA 1 20 A -- SPARE 34
31 LTG - L2 EAST Lighting; Other 20 A 1 1253 VA 0 VA 1 20 A -- SPARE 32
29 LTG - L2 NORTH Lighting 20 A 1 1160 VA 0 VA 1 20 A -- SPARE 30
27 LTG - L2 WEST Lighting 20 A 1 1320 VA 0 VA 1 20 A -- SPARE 28
25 LTG - STAIR 2 Other 20 A 1 34 VA 0 VA 1 20 A -- SPARE 26
23 LTG - L1 CENTER OFFICES Lighting 20 A 1 840 VA 0 VA 1 20 A -- SPARE 24
21 LTG - L1 NORTHWEST Lighting 20 A 1 1245 VA 0 VA 1 20 A -- SPARE 22
19 LTG - L1 SOUTHEAST Lighting 20 A 1 758 VA 0 VA 1 20 A -- SPARE 20
17 LTG - L1 SOUTH Lighting; Other 20 A 1 1223 VA 0 VA 1 20 A -- SPARE 18
15 LTG - L1 SOUTHWEST Lighting 20 A 1 978 VA 0 VA 1 20 A -- SPARE 16
13 LTG - L1 HALLS Lighting 20 A 1 1461 VA 0 VA 1 20 A -- SPARE 14
11 LTG - CONF/RR/STG/JAN Lighting; Other 20 A 1 533 VA 0 VA 1 20 A -- SPARE 12
9 LTG - L1 ENT/LOB/RECEP Lighting 20 A 1 1198 VA 0 VA 1 20 A -- SPARE 10
7 LTG - L1 MEETING RM Lighting 20 A 1 1276 VA 0 VA 1 20 A -- SPARE 8
5 LTG - EXTERIOR Lighting 20 A 1 489 VA 133 VA 1 20 A Lighting PAVILION 6
3 LTG - LOWER LEVEL Lighting 20 A 1 953 VA 154 VA 1 20 A Lighting LTG-FRONT PARKING LOT 4
1 RCPT GFI - ELEV LTG Lighting; Receptacle 20 A 1 244 VA 736 VA 1 20 A Lighting LTG-WEST PARKING LOT 2
CKT Circuit Description Load
Classification Trip Poles A B C Poles Trip Load
Classification Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 200 A
Supply From: MDP Phases: 3 Mains Type: MLO
Location: ELEC. CLOS. 110 Volts: 120/208 Wye A.I.C. Rating: 10,181 A
Branch Panel: L1
Notes:
Total Est. Demand: 10 A
Total Conn.: 10 A
Total Est. Demand: 3740 VA
Receptacle 3240 VA 100.00% 3240 VA Total Conn. Load: 3740 VA
Power 500 VA 100.00% 500 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 13 A 9 A 9 A
Total Load: 1580 VA 1080 VA 1080 VA
41 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 42
39 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 40
37 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 38
35 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 36
33 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 34
31 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 32
29 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 30
27 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 28
25 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 26
23 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 24
21 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 22
19 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 20
17 RCPT - SERVER RACK 6 Receptacle 20 A 1 180 VA 0 VA 1 20 A -- SPARE 18
15 RCPT - SERVER RACK 5 Receptacle 20 A 1 180 VA 0 VA 1 20 A -- SPARE 16
13 RCPT - SERVER RACK 4 Receptacle 20 A 1 180 VA 0 VA 1 20 A -- SPARE 14
11 RCPT - SERVER RACK 3 Receptacle 20 A 1 180 VA 0 VA 1 20 A -- SPARE 12
9 RCPT - SERVER RACK 2 Receptacle 20 A 1 180 VA 0 VA 1 20 A -- SPARE 10
7 RCPT - SERVER RACK 1 Receptacle 20 A 1 180 VA 0 VA 1 20 A -- SPARE 8
5 RCPT - TEL/COMM 3 Receptacle 20 A 1 720 VA 0 VA 1 20 A -- SPARE 6
3 RCPT - TEL/COMM 2 Receptacle 20 A 1 720 VA 0 VA 1 20 A -- SPARE 4
1 RCPT - TEL/COMM 1 Power; Receptacle 20 A 1 1220 VA 0 VA 1 20 A -- SPARE 2
CKT Circuit Description Load
Classification Trip Poles A B C Poles Trip Load
Classification Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 100 A
Supply From: MDP Phases: 3 Mains Type: MLO
Location: TEL/COMM 002 Volts: 120/208 Wye A.I.C. Rating: 12,193 A
Branch Panel: C1
R
O
FE
SS IONAL ENG INEE
RL
I C E N S ED
S T
A
T E O F I D
A H
O
A R
I AN
C . B LOOMF
I E L
D
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:3 :1
P
M
E9.10
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCHEDULES
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
RJH
BMM
ACB
Notes:
Total Est. Demand: 390 A
Total Conn.: 386 A
Receptacle 180 VA 100.00% 180 VA Total Est. Demand: 140516 VA
Power 119013 VA 100.00% 119013 VA Total Conn. Load: 139210 VA
Motor 20017 VA 106.52% 21323 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 395 A 369 A 402 A
Total Load: 47037 VA 44315 VA 47858 VA
83 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 84
81 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 82
79 2000 VA 0 VA 1 20 A -- SPARE 80
EH-302 Power 25 A 2
2000 VA 0 VA 1 20 A -- SPARE 78
75 3651 VA 0 VA 1 20 A -- SPARE 76
73 3651 VA 0 VA 1 20 A -- SPARE 74
HP-1 (3) Power 40 A 3
3651 VA 0 VA 1 20 A -- SPARE 72
69 4131 VA 0 VA 1 20 A -- SPARE 70
67 4131 VA 0 VA 1 20 A -- SPARE 68
HP-1 (2) Power 50 A 3
4131 VA 0 VA 1 20 A -- SPARE 66
63 5947 VA 0 VA 1 20 A -- SPARE 64
61 5947 VA 0 VA 1 20 A -- SPARE 62
HP-1 (1) Power 70 A 3
5947 VA 0 VA 1 20 A -- SPARE 60
57 UH-1 Power 20 A 1 1176 VA 0 VA 1 20 A -- SPARE 58
55 EH-106 Power 20 A 1 1500 VA 0 VA 1 20 A -- SPARE 56
53 EH-139 Power 20 A 1 1500 VA 0 VA 1 20 A -- SPARE 54
51 EH-128 Power 20 A 1 1500 VA 0 VA 1 20 A -- SPARE 52
49 EH-126 Power 20 A 1 1500 VA 0 VA 1 20 A -- SPARE 50
47 EH-101 Power 20 A 1 1500 VA 0 VA 1 20 A -- SPARE 48
45 354 VA 0 VA 1 20 A -- SPARE 46
FC-143 Motor 15 A 2
354 VA 0 VA 1 20 A -- SPARE 44
41 385 VA 0 VA 1 20 A -- SPARE 42
FC-137 & 139 Motor 15 A 2
385 VA 0 VA 1 20 A -- SPARE 40
37 291 VA 0 VA 1 20 A -- SPARE 38
FC-136 Motor 15 A 2
291 VA 600 VA 1 20 A Power FSD LEVEL 1 & BSMT 36
33 416 VA 500 VA 1 20 A Power FSD LEVEL 2 & ATTIC 34
FC-127 & 131 Motor 15 A 2
416 VA 500 VA 1 20 A Motor EF-1 32
29 187 VA 1120 VA 1 20 A Power LAVATORY FAUCET 30
FC-123 Motor 15 A 2
187 VA 6000 VA 28
25 156 VA 6000 VA 26
FC-122b Motor 15 A 2
156 VA 6000 VA
3 70 A Power DWH-1
21 291 VA 125 VA 22
FC-122a Motor 15 A 2
291 VA 125 VA
2 15 A Power BS-1 THROUGH BS-12
17 250 VA 4131 VA 18
FC-114 & 117 Motor 15 A 2
250 VA 4131 VA 16
13 936 VA 4131 VA
3 50 A Power HP-2 (3)
FC-105b Motor 15 A 2
936 VA 4131 VA 12
9 936 VA 4131 VA 10
FC-105a Motor 15 A 2
936 VA 4131 VA
3 50 A Power HP-2 (2)
5 333 VA 4131 VA 6
FC-103 &104 Motor 15 A 2
333 VA 4131 VA 4
1 RCPT GFI - ELEV SUMP PUMP Receptacle 20 A 1 180 VA 4131 VA
3 50 A Power HP-2 (1)
CKT Circuit Description Load
Classification Trip Poles A B C Poles Trip Load
Classification Circuit Description CKT
PROVIDE FEED THRU LUGS.
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 600 A
Supply From: MDP Phases: 3 Mains Type: MLO
Location: MECHANICAL ROOM 003 Volts: 120/208 Wye A.I.C. Rating: 15,195 A
Branch Panel: M1
Notes:
Total Est. Demand: 53 A
Total Conn.: 50 A
Total Est. Demand: 19252 VA
Power 7498 VA 100.00% 7498 VA Total Conn. Load: 17946 VA
Motor 10448 VA 112.50% 11754 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 48 A 48 A 54 A
Total Load: 5729 VA 5739 VA 6477 VA
71 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 72
69 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 70
67 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 68
65 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 66
63 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 64
61 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 62
59 LAVATORY FAUCET Power 20 A 1 800 VA 0 VA 1 20 A -- SPARE 60
57 3483 VA 0 VA 1 20 A -- SPARE 58
55 3483 VA 0 VA 1 20 A -- SPARE 56
ERV-1 Motor 45 A 3
3483 VA 0 VA 1 20 A -- SPARE 54
51 146 VA 0 VA 1 20 A -- SPARE 52
BS-13 THROUGH BS26 Power 15 A 2
146 VA 0 VA 1 20 A -- SPARE 50
47 354 VA 0 VA 1 20 A -- SPARE 48
FC-237 Power 15 A 2
354 VA 0 VA 1 20 A -- SPARE 46
43 302 VA 0 VA 1 20 A -- SPARE 44
FC-234 Power 15 A 2
302 VA 0 VA 1 20 A -- SPARE 42
39 83 VA 0 VA 1 20 A -- SPARE 40
FC-232 Power 15 A 2
83 VA 0 VA 1 20 A -- SPARE 38
35 291 VA 0 VA 1 20 A -- SPARE 36
FC-231 Power 15 A 2
291 VA 0 VA 1 20 A -- SPARE 34
31 354 VA 0 VA 1 20 A -- SPARE 32
FC-230 Power 15 A 2
354 VA 0 VA 1 20 A -- SPARE 30
27 354 VA 0 VA 1 20 A -- SPARE 28
FC-228 Power 15 A 2
354 VA 0 VA 1 20 A -- SPARE 26
23 166 VA 0 VA 1 20 A -- SPARE 24
FC-226 Power 15 A 2
166 VA 0 VA 1 20 A -- SPARE 22
19 146 VA 0 VA 1 20 A -- SPARE 20
FC-224, & 225 Power 15 A 2
146 VA 0 VA 1 20 A -- SPARE 18
15 156 VA 0 VA 1 20 A -- SPARE 16
FC-216 Power 15 A 2
156 VA 0 VA 1 20 A -- SPARE 14
11 291 VA 0 VA 12
FC-214 Power 15 A 2
291 VA 0 VA
2 15 A -- SPARE
7 291 VA 0 VA 8
FC-205 Power 15 A 2
291 VA 0 VA
2 15 A -- SPARE
3 416 VA 0 VA 4
FC-201, 202, & 204 Power 15 A 2
416 VA 0 VA
2 15 A -- SPARE
CKT Circuit Description Load
Classification Trip Poles A B C Poles Trip Load
Classification Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 600 A
Supply From: M1 Phases: 3 Mains Type: MLO
Location: MECHANICAL ROOM 003 Volts: 120/208 Wye A.I.C. Rating: 15,195 A
Branch Panel: M2
R
O
FE
SS IONAL ENG INEE
RL
I C E N S ED
S T
A
T E O F I D
A H
O
A R
I AN
C . B LOOMF
I E L
D
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:3 :1
P
M
E9.11
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCHEDULES
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
RJH
BMM
ACB
Notes:
Total Est. Demand: 212 A
Total Conn.: 385 A
Receptacle 134280 VA 53.72% 72140 VA Total Est. Demand: 76440 VA
Power 4300 VA 100.00% 4300 VA Total Conn. Load: 138580 VA
Other 0 VA 0.00% 0 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 413 A 392 A 359 A
Total Load: 49080 VA 46480 VA 43020 VA
41 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 42
39 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 40
37 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 38
35 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 36
33 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 34
31 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 32
29 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 30
27 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 28
25 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 26
23 SPACE -- -- -- 0 VA 0 VA 24
21 SPACE -- -- -- 0 VA 0 VA 22
19 SPACE -- -- -- 0 VA 0 VA
3 200 A -- SPARE
17 0 VA 0 VA 18
15 0 VA 0 VA 16
SPARE -- 200 A 3
0 VA 0 VA
3 200 A -- SPARE
11 9620 VA 9927 VA 12
9 10340... 10347... 10
PNL R1B Receptacle 200 A 3
10700... 13287...
3 200 A Power; Receptacle PNL R2B
5 12773... 10700... 6
3 14733... 11060... 4
PNL R1A
Other; Power;
Receptacle 200 A 3
14573... 10520...
3 200 A Receptacle PNL R2A
CKT Circuit Description Load
Classification Trip Poles A B C Poles Trip Load
Classification Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 600 A
Supply From: MDP Phases: 3 Mains Type: MLO
Location: MECHANICAL ROOM 003 Volts: 120/208 Wye A.I.C. Rating: 9,405
Branch Panel: MDR
R
O
FE
SS IONAL ENG INEE
RL
I C E N S ED
S T
A
T E O F I D
A H
O
A R
I AN
C . B LOOMF
I E L
D
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:3 :1
P
M
E9.12
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCHEDULES
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
RJH
BMM
ACB
Notes:
Total Est. Demand: 77 A
Total Conn.: 117 A
Receptacle 38780 VA 62.89% 24390 VA Total Est. Demand: 27690 VA
Power 3300 VA 100.00% 3300 VA Total Conn. Load: 42080 VA
Other 0 VA 0.00% 0 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 124 A 125 A 106 A
Total Load: 14573 VA 14733 VA 12773 VA
83 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 84
81 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 82
79 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 80
77 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 78
75 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 76
73 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 74
71 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 72
69 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 70
67 CCTV MONITOR Receptacle 20 A 1 180 VA 0 VA 1 20 A -- SPARE 68
65 CCTV MONITOR Receptacle 20 A 1 180 VA 0 VA 1 20 A -- SPARE 66
63 RCPT - BLM OFFICE 120 Receptacle 20 A 1 1080 VA 0 VA 1 20 A -- SPARE 64
61 RCPT - BLM OFFICE 119 Receptacle 20 A 1 1080 VA 0 VA 1 20 A -- SPARE 62
59 RCPT - BLM OFFICE 118 Receptacle 20 A 1 1080 VA 500 VA 1 20 A Power ELEVATOR CAR LIGHTS 60
57 RCPT - BLM OFFICE 117-1 Receptacle 20 A 1 1080 VA 500 VA 1 20 A Power ELEVATOR CONTROLS 58
55 RCPT - BLM OFFICE 116 Receptacle 20 A 1 1080 VA 0 VA 1 20 A Other INTRUSION PANEL 56
53 RCPT - BLM OFFICE 115 Receptacle 20 A 1 1080 VA 0 VA 1 20 A Other SECURITY PANEL 54
51 RCPT - CONF 114-2 Receptacle 20 A 1 720 VA 0 VA 1 20 A Other FACP 52
49 RCPT - CONF 114-1 Receptacle 20 A 1 860 VA 700 VA 1 20 A Power CARD READERS - INTERIOR 50
47 RCPT GFI - RSTRM 108/109 Receptacle 20 A 1 360 VA 600 VA 1 20 A Power CARD READERS - EXTERIOR 48
45 RCPT GFI - WATER FOUNTAIN Receptacle 20 A 1 500 VA 1080 VA 1 20 A Receptacle RCPT - LAW OFFICE 135 46
43 RCPT GFI - STR/VEST/EXT Receptacle 20 A 1 720 VA 1080 VA 1 20 A Receptacle RCPT - LAW OFFICE 134 44
41 PHONE BOOTH PWR/LTG 106 Power 20 A 1 500 VA 1080 VA 1 20 A Receptacle RCPT - LAW OFFICE 133 42
39 RCPT GFI - MTG 105-5 Receptacle 20 A 1 540 VA 1080 VA 1 20 A Receptacle RCPT - LAW OFFICE 132 40
37 RCPT GFI - MTG 105-4 Receptacle 20 A 1 540 VA 720 VA 1 20 A Receptacle RCPT - LAW ENF 131 38
35 RCPT - MTG 105-3 Receptacle 20 A 1 900 VA 360 VA 1 20 A Receptacle RCPT - EVIDENCE 130 36
33 RCPT - MTG 105-2 Receptacle 20 A 1 900 VA 900 VA 1 20 A Receptacle RCPT - VEST 128/EXT 34
31 RCPT GFI - MTG 105-1/EXT Receptacle 20 A 1 720 VA 720 VA 1 20 A Receptacle RCPT - CORR 113-4 32
29 RCPT - MTG 105 FLR 4 Receptacle 20 A 1 1000 VA 720 VA 1 20 A Receptacle RCPT - CORR 113-3 30
27 RCPT - MTG 105 FLR 3 Receptacle 20 A 1 1000 VA 720 VA 1 20 A Receptacle RCPT - CORR 113-2 28
25 RCPT - MTG 105 FLR 2 Receptacle 20 A 1 1000 VA 900 VA 1 20 A Receptacle RCPT - CORR 113-1 26
23 RCPT - MTG 105 FLR 1 Receptacle 20 A 1 1000 VA 180 VA 1 20 A Receptacle RCPT - ELEC CLOSET 110 24
21 RCPT - MTG RM 105 PROJECTOR Receptacle 20 A 1 180 VA 533 VA 22
19 RCPT - MTG RM 105 PROJECTOR Receptacle 20 A 1 180 VA 533 VA 20
17 RCPT - CONF 104-2 Receptacle 20 A 1 540 VA 533 VA
3 20 A Receptacle RCPT - CIO OFFICE 127
15 RCPT - CONF 104-1 Receptacle 20 A 1 860 VA 1080 VA 1 20 A Receptacle RCPT - FMO OFFICE 124 16
13 RCPT - MAIL 103A-1 Receptacle 20 A 1 540 VA 180 VA 1 20 A Receptacle RCPT GFI - WATER FOUNTAIN 14
11 RCPT - MAIL 103A-2 Receptacle 20 A 1 720 VA 180 VA 1 20 A Receptacle RCPT GFI - CUST/FOYER 12
9 RCPT - RECEPTION 103-4 Receptacle 20 A 1 720 VA 180 VA 1 20 A Receptacle BSMT BAS PANEL 10
7 RCPT - RECEPTION 103-3 Receptacle 20 A 1 720 VA 860 VA 1 20 A Power; Receptacle RCPT - MECH RM 003 8
5 RCPT - RECEPTION 103-2 Receptacle 20 A 1 540 VA 720 VA 1 20 A Receptacle RCPT - MECH RM 003 6
3 RCPT - RECEPTION 103-1 Receptacle 20 A 1 360 VA 720 VA 1 20 A Receptacle RCPT - BUILDING STORAGE 4
1 RCPT - ENTRY/LOBBY Receptacle 20 A 1 900 VA 360 VA 1 20 A Receptacle RCPT - PRIVACY RM 121 2
CKT Circuit Description Load
Classification Trip Poles A B C Poles Trip Load
Classification Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 200 A
Supply From: MDR Phases: 3 Mains Type: MLO
Location: ELEC. CLOS. 110 Volts: 120/208 Wye A.I.C. Rating: 7,470 A
Branch Panel: R1A
Notes:
Total Est. Demand: 56 A
Total Conn.: 85 A
Total Est. Demand: 20330 VA
Total Conn. Load: 30660 VA
Receptacle 30660 VA 66.31% 20330 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 90 A 87 A 80 A
Total Load: 10700 VA 10340 VA 9620 VA
83 533 VA 0 VA 1 20 A -- SPARE 84
81 533 VA 0 VA 1 20 A -- SPARE 82
RCPT - FMO OPEN OFFICE 123 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 80
77 533 VA 0 VA 1 20 A -- SPARE 78
75 533 VA 0 VA 1 20 A -- SPARE 76
RCPT - FMO OPEN OFFICE 123 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 74
71 533 VA 0 VA 1 20 A -- SPARE 72
69 533 VA 0 VA 1 20 A -- SPARE 70
RCPT - BLM OPEN OFFICE 123 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 68
65 533 VA 0 VA 1 20 A -- SPARE 66
63 533 VA 0 VA 1 20 A -- SPARE 64
RCPT - BLM OPEN OFFICE 123 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 62
59 533 VA 0 VA 60
57 533 VA 0 VA 58
RCPT - BLM OPEN OFFICE 122 Receptacle 20 A 3
533 VA 0 VA
3 20 A -- SPARE
53 533 VA 0 VA 54
51 533 VA 0 VA 52
RCPT - BLM OPEN OFFICE 122 Receptacle 20 A 3
533 VA 0 VA
3 20 A -- SPARE
47 533 VA 0 VA 48
45 533 VA 0 VA 46
RCPT - BLM OPEN OFFICE 122 Receptacle 20 A 3
533 VA 0 VA
3 20 A -- SPARE
41 533 VA 533 VA 42
39 533 VA 533 VA 40
RCPT - BLM OPEN OFFICE 122 Receptacle 20 A 3
533 VA 533 VA
3 20 A Receptacle RCPT - FHP OPEN OFFICE 143
35 SPARE -- 20 A 1 0 VA 533 VA 36
33 SPARE -- 20 A 1 0 VA 533 VA 34
31 RCPT - FHP OFFICE 144 Receptacle 20 A 1 1080 VA 533 VA
3 20 A Receptacle RCPT - FHP OPEN OFFICE 143
29 RCPT - OPEN OFFICE 143-1 Receptacle 20 A 1 540 VA 533 VA 30
27 RCPT - FHP/BLM STG 142 Receptacle 20 A 1 720 VA 533 VA 28
25 RCPT GFI - RSTRM 140/141 Receptacle 20 A 1 360 VA 533 VA
3 20 A Receptacle RCPT - FHP OPEN OFFICE 143
23 RCPT - BKRM 139-3 Receptacle 20 A 1 540 VA 533 VA 24
21 RCPT GFI - BKRM 139-2 Receptacle 20 A 1 360 VA 533 VA 22
19 RCPT GFI - BKRM 139 DWASH Receptacle 20 A 1 180 VA 533 VA
3 20 A Receptacle RCPT - FHP OPEN OFFICE 143
17 RCPT GFI - BKRM 139 FRIG Receptacle 20 A 1 180 VA 533 VA 18
15 RCPT - BKRM 139-1 Receptacle 20 A 1 540 VA 533 VA 16
13 RCPT - CONF 138 Receptacle 20 A 1 720 VA 533 VA
3 20 A Receptacle RCPT - BLM OPEN OFFICE 136
11 RCPT - PRINTER 137 Receptacle 15 A 1 180 VA 533 VA 12
9 RCPT - PRINTER 137 Receptacle 15 A 1 180 VA 533 VA 10
7 RCPT - PRINTER 137 Receptacle 15 A 1 180 VA 533 VA
3 20 A Receptacle RCPT - BLM OPEN OFFICE 136
5 RCPT - PRINTER 137 Receptacle 15 A 1 180 VA 533 VA 6
3 RCPT - PRINT ROOM 137 Receptacle 20 A 1 540 VA 533 VA 4
1 RCPT - PRINT ROOM 137 Receptacle 20 A 1 180 VA 533 VA
3 20 A Receptacle RCPT - BLM OPEN OFFICE 136
CKT Circuit Description Load
Classification Trip Poles A B C Poles Trip Load
Classification Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 200 A
Supply From: MDR Phases: 3 Mains Type: MLO
Location: ELEC. CLOS. 110 Volts: 120/208 Wye A.I.C. Rating: 7,470 A
Branch Panel: R1B
R
O
FE
SS IONAL ENG INEE
RL
I C E N S ED
S T
A
T E O F I D
A H
O
A R
I AN
C . B LOOMF
I E L
D
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:3 :1
P
M
E9.13
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCHEDULES
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
RJH
BMM
ACB
Notes:
Total Est. Demand: 59 A
Total Conn.: 90 A
Total Est. Demand: 21140 VA
Total Conn. Load: 32280 VA
Receptacle 32280 VA 65.49% 21140 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 88 A 92 A 89 A
Total Load: 10520 VA 11060 VA 10700 VA
83 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 84
81 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 82
79 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 80
77 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 78
75 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 76
73 533 VA 0 VA 1 20 A -- SPARE 74
71 533 VA 0 VA 1 20 A -- SPARE 72
RCPT - TEC OPEN OFFICE 228 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 70
67 533 VA 0 VA 1 20 A -- SPARE 68
65 533 VA 0 VA 1 20 A -- SPARE 66
RCPT - TEC OPEN OFFICE 228 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 64
61 533 VA 0 VA 1 20 A -- SPARE 62
59 533 VA 0 VA 60
RCPT - TEC OPEN OFFICE 228 Receptacle 20 A 3
533 VA 0 VA 58
55 533 VA 0 VA
3 20 A -- SPARE
53 533 VA 0 VA 54
RCPT - TEC OPEN OFFICE 228 Receptacle 20 A 3
533 VA 0 VA 52
49 533 VA 0 VA
3 20 A -- SPARE
47 533 VA 0 VA 48
RCPT - HRM OPEN OFFICE 226 Receptacle 20 A 3
533 VA 0 VA 46
43 533 VA 0 VA
3 20 A -- SPARE
41 533 VA 0 VA 42
RCPT - HRM OPEN OFFICE 226 Receptacle 20 A 3
533 VA 0 VA 40
37 533 VA 0 VA
3 20 A -- SPARE
35 533 VA 533 VA 36
RCPT - FWS OPEN OFFICE 205 Receptacle 20 A 3
533 VA 533 VA 34
31 533 VA 533 VA
3 20 A Receptacle RCPT - VEG OPEN OFFICE 231
29 533 VA 533 VA 30
RCPT - FWS OPEN OFFICE 205 Receptacle 20 A 3
533 VA 533 VA 28
25 533 VA 533 VA
3 20 A Receptacle RCPT - VEG OPEN OFFICE 231
23 533 VA 533 VA 24
RCPT - FWS OPEN OFFICE 205 Receptacle 20 A 3
533 VA 533 VA 22
19 CCTV MONITOR Receptacle 20 A 1 180 VA 533 VA
3 20 A Receptacle RCPT - VEG OPEN OFFICE 231
17 RCPT - WAIT/FILING 213/216 Receptacle 20 A 1 1080 VA 533 VA 18
15 RCPT - SUP OFFICE 214 Receptacle 20 A 1 1260 VA 533 VA 16
13 RCPT - DEP SUP OFFICE 212 Receptacle 20 A 1 1080 VA 533 VA
3 20 A Receptacle RCPT - AQM OPEN OFFICE 230
11 RCPT - FWS SUP OFFICE 211 Receptacle 20 A 1 1080 VA 533 VA 12
9 RCPT - FWS OFFICE 206 Receptacle 20 A 1 1080 VA 533 VA 10
7 RCPT - FWS OFFICE 204-2 Receptacle 20 A 1 720 VA 533 VA
3 20 A Receptacle RCPT - AQM OPEN OFFICE 230
5 RCPT - FWS OFFICE 204-1 Receptacle 20 A 1 540 VA 533 VA 6
3 RCPT - FWS OFFICE 203-2 Receptacle 20 A 1 720 VA 533 VA 4
1 RCPT - FWS OFFICE 203-1 Receptacle 20 A 1 540 VA 533 VA
3 20 A Receptacle RCPT - AQM OPEN OFFICE 230
CKT Circuit Description Load
Classification Trip Poles A B C Poles Trip Load
Classification Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 200 A
Supply From: MDR Phases: 3 Mains Type: MLO
Location: STORAGE 207 Volts: 120/208 Wye A.I.C. Rating: 7,655 A
Branch Panel: R2A
Notes:
Total Est. Demand: 62 A
Total Conn.: 93 A
Total Est. Demand: 22280 VA
Receptacle 32560 VA 65.36% 21280 VA Total Conn. Load: 33560 VA
Power 1000 VA 100.00% 1000 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 111 A 87 A 83 A
Total Load: 13287 VA 10347 VA 9927 VA
83 SPARE -- 20 A 1 0 VA 0 VA 84
81 0 VA 0 VA 82
79 0 VA 0 VA
3 20 A -- SPARE
SPARE -- 20 A 3
0 VA 0 VA 1 20 A -- SPARE 78
75 0 VA 0 VA 1 20 A -- SPARE 76
73 0 VA 0 VA 1 20 A -- SPARE 74
SPARE -- 20 A 3
0 VA 0 VA 1 20 A -- SPARE 72
69 533 VA 0 VA 1 20 A -- SPARE 70
67 533 VA 0 VA 1 20 A -- SPARE 68
RCPT - NEP OPEN OFFICE 202 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 66
63 533 VA 0 VA 1 20 A -- SPARE 64
61 533 VA 0 VA 1 20 A -- SPARE 62
RCPT - NEP OPEN OFFICE 202 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 60
57 533 VA 0 VA 1 20 A -- SPARE 58
55 533 VA 0 VA 1 20 A -- SPARE 56
RCPT - ECO OPEN OFFICE 237 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 54
51 533 VA 0 VA 1 20 A -- SPARE 52
49 533 VA 0 VA 1 20 A -- SPARE 50
RCPT - ECO OPEN OFFICE 237 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 48
45 533 VA 0 VA 1 20 A -- SPARE 46
43 533 VA 0 VA 1 20 A -- SPARE 44
RCPT - ECO OPEN OFFICE 237 Receptacle 20 A 3
533 VA 0 VA 1 20 A -- SPARE 42
39 RCPT - HRM OFFICE 218 Receptacle 20 A 1 1080 VA 0 VA 1 20 A -- SPARE 40
37 RCPT - PUBLIC AFFAIRS 217 Receptacle 20 A 1 1080 VA 0 VA 1 20 A -- SPARE 38
35 RCPT - FWS OFFICE 216 Receptacle 20 A 1 1080 VA 500 VA 1 20 A Power PHONE BOOTH PWR/LTG 230 36
33 RCPT - SECURITY COMPUTER 220 Receptacle 20 A 1 180 VA 180 VA 1 20 A Receptacle RCPT - AQM OPEN OFFICE 230 34
31 RCPT - SECURITY OFFICE 220 Power; Receptacle 20 A 1 1580 VA 500 VA 1 20 A Receptacle RCPT GFI - WATER FOUNTAIN 32
29 RCPT - ECO OFFICE 221 Receptacle 20 A 1 1080 VA 180 VA 1 20 A Receptacle ATTIC BAS PANEL 30
27 RCPT - VEG OFFICE 222 Receptacle 20 A 1 1080 VA 360 VA 1 20 A Receptacle RCPT - ATTIC MAINTENANCE 28
25 RCPT - NIZ OFFICE 219 Receptacle 20 A 1 1080 VA 720 VA 1 20 A Receptacle RCPT - ATTIC MAINTENANCE 26
23 RCPT - TEC OFFICE 223 Receptacle 20 A 1 1080 VA 720 VA 1 20 A Receptacle RCPT - CONF 233 24
21 RCPT - CORR 210C-1 Receptacle 20 A 1 720 VA 180 VA 1 15 A Receptacle RCPT - PRINTER 232 22
19 RCPT - CORR 210C-2 Receptacle 20 A 1 720 VA 180 VA 1 15 A Receptacle RCPT - PRINTER 232 20
17 RCPT - STORAGE 207 Receptacle 20 A 1 180 VA 180 VA 1 15 A Receptacle RCPT - PRINTER 232 18
15 RCPT - CORR 210A-2 Receptacle 20 A 1 720 VA 180 VA 1 15 A Receptacle RCPT - PRINTER 232 16
13 RCPT - CORR 210A-1 Receptacle 20 A 1 900 VA 540 VA 1 20 A Receptacle RCPT - PRINT RM 232-2 14
11 RCPT - CONF 224-1 Receptacle 20 A 1 860 VA 180 VA 1 20 A Receptacle RCPT - PRINT RM 232-1 12
9 RCPT - CONF 224-2 Receptacle 20 A 1 720 VA 360 VA 1 20 A Receptacle RCPT GFI - RSTRM 235/236 10
7 RCPT - CONF 225-2 Receptacle 20 A 1 540 VA 720 VA 1 20 A Receptacle RCPT - BKRM 234-2 8
5 RCPT - CONF 225-1 Receptacle 20 A 1 860 VA 360 VA 1 20 A Receptacle RCPT GFI - BKRM 234-1 6
3 RCPT - CONF 201-2 Receptacle 20 A 1 720 VA 1200 VA 1 20 A Receptacle RCPT GFI - BKRM 234 DWASH 4
1 RCPT - CONF 201-1 Receptacle 20 A 1 860 VA 1200 VA 1 20 A Receptacle RCPT GFI - BKRM 234 FRIG 2
CKT Circuit Description Load
Classification Trip Poles A B C Poles Trip Load
Classification Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 200 A
Supply From: MDR Phases: 3 Mains Type: MLO
Location: STORAGE 207 Volts: 120/208 Wye A.I.C. Rating: 7,655 A
Branch Panel: R2B
& SUPPORTS NOTES
VALVES, HANGERS
GATE VALVES:
1. UP TO AND INCLUDING 2 INCHES (50MM): BRONZE BODY, BRONZE
TRIM, RISING STEM, HANDWHEEL, INSIDE SCREW, SINGLE WEDGE
OR DISC, TREADED ENDS.
2. OVER 2 INCHES (50MM): IRON BODY, BRONZE TRIM, RISING STEM,
HANDWHEEL, OS&Y, SOLID WEDGE, FLANGED ENDS.
GLOBE (OR ANGLE) VALVES:
1. UP TO 2 INCHES (50MM): BRONZE BODY, BRONZE TRIM, RISING
STEM AND HANDWHEEL, INSIDE SCREW, RENEWABLE
COMPOSITION DISC, SCREWED ENDS, WITH BACKSEATING
CAPACITY RE-PACKABLE UNDER PRESSURE.
2. OVER 2 INCHES (50MM): IRON BODY, BRONZE TRIM, RISING STEM,
HANDWHEEL, OS&Y, PLUG-TYPE DISC, FLANGED ENDS,
RENEWABLE SEAT AND DISC.
BALL VALVES:
1. UP TO AND INCLUDE 2 INCHES (50MM): BRONZE TWO-PIECE BODY,
STAINLESS STEEL BALL, TEFLON SEATS AND STUFFING BOX RING,
LEVER HANDLE, TREADED ENDS WITH UNION.
BUTTERFLY VALVES:
1. CAST OR DUCTILE IRON BODY, CHROME OR NICKEL PLATED
DUCTILE IRON DISC, RESILIENT REPLACEABLE EPDM SEAT, WAFER
OR LUG ENDS, EXTENDED NECK, HANDWHEEL AND GEAR DRIVE
AND INTEGRAL INDICATING DEVICE.
CHECK VALVES:
1. UP TO AND INCLUDING 2 INCHES: BRONZE SWING DISC, SCREWED
ENDS.
2. OVER 2 INCHES (50MM): IRON BODY, BRONZE TRIM, SWING DISC,
RENEWABLE DISC AND SEAT, FLANGED ENDS.
3. IRON BODY, BRONZE TRIM, STAINLESS STEEL SPRING,
RENEWABLE COMPOSITION DISC. SCREWED, WAFER OR FLANGED
ENDS.
DRAIN VALVES:
1. BRONZE GLOBE VALVE WITH HOSE THREAD NIPPLE AND CAP.
2. BRASS BALL VALVE WITH CAP, ¾ INCH (19MM) HOSE THREAD.
PIPE HANGERS AND SUPPORTS:
1. CONFORM TO NFPA 13. HANGERS SHALL BE UL LISTED FOR USE IN
SPRINKLER SYSTEMS.
2. HANGERS FOR PIPE SIZES ½ TO 1-1/2 INCH (15 T0 40MM): STEEL,
ADJUSTABLE SWIVEL, SPLIT RING.
3. HANGERS FOR PIPE SIZES 2 INCHES AND OVER:STEEL,
ADJUSTABLE CLEVIS.
4. MULTIPLE OR TRAPEZE HANGERS: STEEL CHANNELS WITH
WELDED SPACERS AND HANGER RODS.
5. WALL SUPPORT FOR PIPE SIZES TO 3 INCHES: CAST IRON HOOK.
6. WALL SUPPORT FOR PIPE SIZES 4 INCHES AND OVER: WELDED
STEEL BRACKET AND WROUGHT STEEL CLAMP.
7. VERTICAL SUPPORT: STEEL RISER CLAMP.
8. FLOOR SUPPORT: CAST IRON ADJUSTABLE PIPE SADDLE, LOCK
NUT, NIPPLE, FLOOR FLANGE, AND CONCRETE PIER OR STEEL
SUPPORT.
PIPING SPECIFICATIONS
SPRINKLER PIPING, BURIED:
1. WATER PIPING OUTSIDE THE BUILDING LARGER THAN 3” SHALL BE
DUCTILE IRON WITH MECHANICAL JOINTS.
2. DUCTILE IRON PIPE SHALL BE CENTRIFUGALLY CAST 18-FOOT
NOMINAL LENGTHS CONFORMING TO AWWA C151 AND SHALL
HAVE A CEMENT-MORTAR LINING CONFORMING TO AWWA C104.
DUCTILE IRON PIPE TO BE JOINTED USING RESTRAINED
MECHANICAL JOINTS SHALL BE STANDARD THICKNESS CLASS 53.
ALL OTHER DUCTILE IRON PIPE SHALL BE STANDARD THICKNESS
CLASS 50 OR THE THICKNESS CLASS AS SHOWN ON THE PLANS.
3. NON-RESTRAINED JOINTS SHALL BE RUBBER GASKET, PUSH-ON
TYPE, OR MECHANICAL CONFORMING TO AWWA C111.
RESTRAINED JOINS MAY BE THE SNAP-LOK RESTRAIN JOINT
SYSTEM INCLUDING THE MECHANICAL JOINT SYSTEM AS
MANUFACTURED BY GRIFFIN PIPE PRODUCTS CO.
4. FITTINGS FOR DUCTILE IRON PIPE SHALL BE DUCTILE IRON OR
CLASS 250 GRAY IRON CONFORMING TO AWWA C110 AND C111
AND SHALL BE CEMENT-MORTAR LINED CONFORMING TO AWWA
C104. PLAIN END FITTINGS SHALL BE DUCTILE IRON IF
MECHANICAL JOINT RETAINER GLANDS ARE INSTALLED ON THE
PLAIN END.
SPRINKLER PIPING, ABOVE GROUND (STEEL PIPE):
1. 1" TO 2" TO BE SCHEDULE 40, BLACK CLASS-125 CAST IRON
THREADED FITTINGS (175 PSI RATED).
2. 2-1/2" TO 4" TO BE SCHEDULE 10 WITH GROOVED ENDS AND
WELDED OUTLETS. PAINTED DUCTILE IRON GROOVED FITTINGS
(300 PSI RATED).
3. 2" AND SMALLER DRAIN PIPING SHALL BE GALVANIZED CLASS-150
MALLEABLE IRON WITH THREADED FITTINGS (300 PSI RATED).
FITTINGS:
1. SCHEDULE 40, BLACK STEEL PIPE: SCREWED JOINTS, ANSI B16.3,
WELDED JOINTS ANSI 16.9, B16.25, MECHANICAL GROOVED
COUPLINGS JOINED BY AN UL AND FM APPROVED COMBINATION
OF BOLTED COUPLINGS, GASKETS AND GROOVES. GROOVES MAY
BE ROLLED OR CUT AND BE DIMENSIONALLY COMPATIBLE WITH
THE COUPLING.
2. SCHEDULE 10, BLACK STEEL: WELDED JOINTS, ANSI 16.3, B16.25,
AND BY UL AND FM APPROVED MECHANICAL COUPLINGS.
COUPLINGS MAY BE OF THE BOLTED ROLLED GROOVED TYPE OR
THE MECHANICAL LOCKING TYPE. GROOVES FOR THE ROLLED
TYPE SHALL BE ROLLED ONLY.
3. CAST IRON SCREWED: ANSI B16.4.
4. CAST IRON FLANGED: ANSI B16.1, OR AWWA C 207.
5. SADDLE TYPE MECHANICAL TEES SHALL BE ACCEPTABLE FOR
CONCEALED PIPE ONLY.
6. PLAIN-END FITTINGS/JOINTS SHALL NOT BE ACCEPTABLE.
7. MECHANICAL PIPE COUPLING HOUSINGS SHALL BE OF MALLEABLE
IRON CONFORMING TO ASTM A 47, GRADE 32510 OR DUCTILE IRON
CONFORMING TO ASTM A 536, GRADE 65-45-12. COUPLING NUTS
AND BOLTS SHALL BE OF STEEL AND CONFORM T ASTM A183.
8. FLANGE GASKETS: GASKETS SHALL BE NON-ASBESTOS
COMPRESSED MATERIAL IN ACCORDANCE WITH ASME B16.21, 1/16
INCH THICKNESS, FULL FACE OR SELF-CENTERING FLAT RING
TYPE. THE GASKETS SHALL CONTAIN ARAMID FIBERS BONDED
WITH STYRENE BUTADIENE RUBBER (SBR) OR NITRILE BUTADIENE
RUBBER (NBR).
9. SQUAREHEAD BOLTS AND HEAVY HEXAGON NUTS: ASME B18.2.1
AND ASME B18.2.2, AND ASTM A 307, ASTM A575, OR ASTM A 576.
FIRE PROTECTION GENERAL NOTES
A. THE INFORMATION CONTAINED WITHIN THESE DRAWINGS IS
INTENDED TO BE USED AS A PERFOMANCE-BASED DESIGN ONLY.
A NICET LEVEL III OR IV CERTIFIED DESIGNER SHALL PROVIDE A
COMPLETE NFPA 13, HYDRAULIC-CALCULATED DESIGN AND
SUBMIT TO THE ENGINEER FOR APPROVAL.
B. ALL BUILDING AREAS SHOWN ON THESE PLANS ARE TO BE FULLY
SPRINKLED TO PROTECT THE OCCUPANTS AND THE STRUCTURES.
A COMPLETE NFPA 13 DESIGN IS REQUIRED.
C. FIRE PROTECTION CONTRACTOR (FPC) SHALL SUBMIT ALL SHOP
DRAWINGS AND CALCULATIONS TO LOCAL AUTHORITY HAVING
JURISDICTION (AHJ) AND RECEIVE APPROVAL PRIOR TO STARTING
CONSTRUCTION.
D. COORDINATE THE LAYOUT OF ALL PIPING WITH EXISTING
CONDITIONS PRIOR TO THE COMPLETION OF THE SHOP
DRAWINGS. FIELD VERIFICATION REQUIRED.
E. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO INSTALL
THE SYSTEM SO THAT NO INTERFERENCES EXIST BETWEEN THE
FIRE PROTECTION PIPING AND EQUIPMENT AND SYSTEMS
INSTALLED BY OTHER DISCIPLINES.
F. CONTRACTOR IS TO BE RESPONSIBLE FOR FEES AND PERMIT
COSTS RELATED TO INSTALLING THE SYSTEM.
G. THE CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR FIELD
FITTING PIPING AS REQUIRED TO COMPLETE THE DESIGN. NOT
ALL PIPING OFFSETS AND FITTINGS REQUIRED HAVE BEEN
SHOWN. THE CONTRACTOR IS TO VERIFY EXACT PIPING CUT
LENGTHS AND DROP HEIGHTS.
H. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED INCIDENTAL
DEVICES, VALVES, SWITCHES, PIPING, ETC., TO ACHIEVE A
COMPLETELY OPERATIONAL, FULLY FUNCTIONING SYSTEM
WHETHER INDICATED ON THE DRAWINGS OR NOT.
I. ALL MATERIALS & INSTALLATIONS OF THIS AUTOMATIC FIRE
SPRINKLER SYSTEM MUST CONFORM TO THE CURRENT EDITION
(APPROVED BY THE AHJ) OF NFPA 13 AND / OR 14.
J. UNDERGROUND PIPING TO BE PROVIDED BY OTHERS. TEST AND
FLUSHING CERTIFICATION TO BE PROVIDED BEFORE FPS IS TO
CONNECT TO ANY PIPING.
K. FPS WILL PROVIDE DRAINS IN ACCORDANCE WITH NFPA 13. FPS
DRAINS TO BE PIPED TO OUTSIDE OR AS INDICATED ON
DRAWINGS.
L. ALL SYSTEM PIPING SHALL BE HYDROSTATICALLY TESTED AT 200
PSI OR AT 50 PSI ABOVE THE SYSTEM OPERATING PRESSURE,
WHICHEVER IS GREATER.
M. ALL ELECTRICAL WIRING, CONDUIT, DETECTION, AND
ALARM/CONTROL PANELS TO BE DONE BY ELECTRICAL
CONTRACTOR. TAMPER AND FLOW SWITCHES SHALL BE BY FPC.
N. ALL PAINTING, IF REQUIRED, DONE BY OTHERS, BUT PAYMENT
SHALL BE BY FPC.
O. CUTTING, PATCHING OF FLOORS, WALLS, AND CEILING TO BE
DONE BY OTHERS, BUT PAYMENT SHALL BE BY FPC.
P. ALL REQUIRED SIGNS, HYDRAULIC PLACARDS AND SYSTEM
INFORMATION DISPLAYS SHALL BE PROVIDED BY THE FPC.
Q. THE CONTRACTOR SHALL INTERFACE WITH THE BUILDING FIRE
ALARM SYSTEM IN ACCORDANCE WITH CODE REQUIREMENTS.
R. PROVIDE EXTRA SPRINKLER HEADS UNDER PROVISIONS OF NFPA
13. PROVIDE SUITABLE WRENCHES FOR EACH TYPE OF HEAD.
PROVIDE A METAL STORAGE CABINET IN THE FIRE RISER ROOM.
S. DRY PIPE ALARM CHECK VALVE: PROVIDE DRY PIPE ALARM CHECK
VALVE ASSEMBLY, TRIM, VALVES, DRAINS, PRESSURE GAUGES,
FLOW/PRESSURE SWITCHES, ETC. FOR A COMPLETE INSTALLATION.
T. DRY PIPE AIR COMPRESSOR: PROVIDE A SMALL MAINTENANCE AIR
COMPRESSOR APPROPRIATE FOR THE DRY PIPE SYSTEM SIZE.
STRAP COMPRESSOR TO RISER PIPE AND CONNECT TO ALARM
VALVE WITH AIR MAINTENANCE VALVE ASSEMBLY.
U. FIRE DEPARTMENT CONNECTION: PROVIDE A UL LISTED,
CHROMED DOUBLE-CLAPPER, SIAMESE FIRE DEPARTMENT
CONNECTION AND AUTO BALL DRIP ASSEMBLY WHERE INDICATED
ON THE PLANS.
V. BACKFLOW PREVENTER: PROVIDE UL APPROVED, LOCAL CODE
APPROVED BACKFLOW PREVENTER (DOUBLE CHECK OR RPP).
W. POST INDICATOR VALVE: PROVIDE UL LISTED POST INDICATOR
TYPE VALVE ON FIRE PROTECTION WATER SERVICE MAIN.
ADJUSTABLE, CAST IRON BODY, VERTICAL POST WITH OPERATING
WRENCH.
X. FLUSH ENTIRE PIPING SYSTEM OF FOREIGN MATTER. PIPING SHALL
BE ARRANGED TO PROVIDE COMPLETE SYSTEM DRAINAGE.
PROVIDE ALL NECESSARY AUXILIARY DRAIN VALVES AS REQUIRE.
Y. CONTRACTOR TO FURNISH ALL FIRE ALARM SYSTEM COMPONENTS
PERTAINING TO SPRINKLER SYSTEM. PROVIDE MONITOR
SWITCHES ON ALL CONTROL, ZONE AND SERVICE VALVES. WIRING
FROM MONITOR SWITCHES TO SUPERVISORY ALARM SYSTEM TO
BE INSTALLED UNDER DIVISION 26 OF THE CONTRACT, BUT PAID BY
THIS CONTRACTOR.
Z. ALL PIPING SHALL BE TESTED WITH A HYDROSTATIC TEST OF NOT
LESS THAN 200 PSIG AND ANY LEAKS FOUND SHALL BE
CORRECTED. AT VARIOUS STAGES AND UPON COMPLETION, THE
SYSTEM SHALL BE TESTED IN THE PRESENCE OF THE OWNER'S
REPRESENTATIVE AND FIRE DEPARTMENT IN STRICT ACCORDANCE
WITH NFPA.
AA. PROVIDE SPRINKLER SYSTEM TESTING AND CERTIFICATION
DOCUMENTATION FOR INCLUSION INTO THE PROJECT 0 & M
MANUAL.
AB. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD
VERIFIED. THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
AC. ALL PIPING IN COLD ATTICS SPACES MUST BE PROPERLY
PROTECTED .
AD. CONTRACTOR TO SPRINKLER ALL COMBUSTIBLE CONCEALED
SPACED PER NFPA 13, 2013 EDITION.
AE. MECHANICAL CONTRACTOR SHALL FIRE SEAL ALL PIPING PASSING
THROUGH RATED CONSTRUCTION.
AF. PROVIDE SPRINKLER GUARDS ON HEADS WHERE SUBJECT TO
DAMAGE.
AG. PROVIDE SPRINKLER DEFLECTOR SHIELDS WHERE REQUIRED.
INSTALLATION REQUIREMENTS
PIPE HANGERS AND SUPPORTS:
1. PROVIDE HANGERS, BRACKETS, SUPPORTS, ANCHORS, AND
RELATED APPURTENANCES, AS REQUIRED, TO SUPPORT ALL
PIPING AND EQUIPMENT PROVIDED UNDER THIS SECTION.
2. INSTALL IN ACCORDANCE WITH NFPA 13 AND UL LISTING.
3. INSTALL HANGERS TO PROVIDE MINIMUM ½ INCH (15MM) SPACE
BETWEEN FINISHED COVERING AND ADJACENT WORK.
4. PLACE HANGERS WITHIN 12 INCHES (300MM) OF EACH
HORIZONTAL ELBOW.
5. USE HANGERS WITH 1-1/2 INCH (40MM) MINIMUM VERTICAL
ADJUSTMENT. DESIGN HANGERS FOR PIPE MOVEMENT WITHOUT
DISENGAGEMENT OF SUPPORTED PIPE.
6. SUPPORT VERTICAL PIPING AT EVERY FLOOR. SUPPORT RISER
PIPING INDEPENDENTLY OF CONNECTED HORIZONTAL PIPING.
7. WHERE SEVERAL PIPES CAN BE INSTALLED IN PARALLEL AND AT
SAME ELEVATION, PROVIDE MULTIPLE OR TRAPEZE HANGERS.
8. PIPE HANGERS OR SUPPORTS TO BE SPACED 15'-0" 0.C. MAX. FOR
PIPES 1-1/2" AND LARGER. 12'-0" O.C. MAX. FOR PIPES 1-1/4" AND
SMALLER. REFER TO PIPE SUPPORT DETAILS FOR CONNECTION
SPECIFICS.
9. ALL BRANCHLINES ARE TO HAVE A HANGER LOCATED WITHIN 1'-0"
OF END OF PIPE.
FLEXIBLE COUPLINGS:
1. FLEXIBLE COUPLINGS SHALL BE LOCATED IN ACCORDANCE WITH
NFPA-13 AS FOLLOWS:
· WITHIN 24" FROM THE TOP AND BOTTOM OF ALL RISERS.
· WITHIN 12" ABOVE AND 24" BELOW FLOORS IN MULTISTORY
BUILDINGS.
· WITHIN 24" OF BUILDING EXPANSION JOINTS.
· WITHIN 24" OF THE TOP OF DROPS EXCEEDING 15'
REGARDLESS OF PIPE SIZE.
· ABOVE AND BELOW ANY INTERMEDIATE POINTS OF SUPPORT
FOR A RISER OR OTHER VERTICAL PIPE.
· THE FINAL CONNECTION AT EACH HEAD IN A LAY-IN OR HARD
CEILING.
BRACING:
SEE SEISMIC BRACING NOTES.
JOINTS:
1. JOINTS SHALL CONFORM TO NFPA 13. SHOP WELDED JOINTS WILL
BE PERMITTED. FLANGED JOINTS OR MECHANICAL GROOVED
COUPLINGS SHALL BE PROVIDED WHERE INDICATED OR
REQUIRED BY NFPA 13. GROOVED PIPE AND FITTINGS SHALL BE
PREPARED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST
PUBLISHED SPECIFICATION ACCORDING TO PIPE MATERIAL, WALL
THICKNESS AND SIZE. MECHANICAL COUPLINGS AND FITTINGS
SHALL BE FROM THE SAME MANUFACTURER.
2. THREADED JOINTS SHALL BE CUT WITH AN APPROVED
THREAD-CUTTING OIL. JOINTS SHALL BE MADE TIGHT WITH A STIFF
MIXTURE OF LITHARGE AND GLYCERIN OR OTHER APPROVED
THREAD JOINT COMPOUND OR TAPE. NOT MORE THAN THREE
THREADS SHALL SHOW AFTER THE JOINT IS MADE UP.
3. FLANGED JOINTS SHALL BE FACED TRUE, PROVIDED WITH
GASKETS AND MADE SQUARE AND TIGHT.
4. MECHANICAL GROOVED PIPE JOINTS SHALL CONFORM TO AWWA
C606. JOINTS SHALL BE MADE USING A UL-04 LISTED OR FM-P7825
APPROVED COMBINATION OF FITTINGS, GASKETS, AND GROOVES.
CUT OR ROLLED PIPE GROOVES SHALL BE DIMENSIONALLY
COMPATIBLE WITH THE FITTINGS.
5. MECHANICAL PIPE COUPLINGS SHALL BE OF THE BOLTED TYPE
AND SHALL CONSIST OF A HOUSING FABRICATED IN ONE OR MORE
PARTS, A SYNTHETIC RUBBER GASKET, AND NUTS AND BOLTS TO
SECURE THE UNIT TOGETHER.
6. GASKETS SHALL BE OF MOLDED SYNTHETIC RUBBER WITH
CENTRAL CAVITY, PRESSURE RESPONSIVE CONFIGURATION AND
SHALL CONFORM TO ASTM D2000.
REDUCERS:
1. REDUCTIONS IN PIPE SIZES SHALL BE MADE WITH ONE PIECE
REDUCING FITTINGS. BUSHINGS WILL NOT BE ACCEPTABLE,
EXCEPT THAT WHEN STANDARD FITTINGS OF THE PROPER SIZE
ARE NOT AVAILABLE, SINGLE BUSHINGS OF THE FACE TYPE WILL
BE PERMITTED. WHERE USED, FACE BUSHINGS SHALL BE
INSTALLED WITH THE OTHER FACE FLUSH WITH THE FACE OF THE
FITTING OPENING BEING REDUCED. BUSHINGS SHALL NOT BE
USED IN ELBOW FITTINGS, IN MORE THAN ONE OUTLET OF A TEE,
IN MORE THAN TWO OUTLETS OF A CROSS, OR WHERE THE
REDUCTION IN SIZE IS LESS THAN ½ INCH.
FLEXIBLE COUPLINGS:
1. PROVIDE LISTED AND APPROVED COUPLINGS ON SPRINKLER
MAINS PER NFPA REGULATIONS. INSTALL UL APPROVED HANGERS
AND EARTHQUAKE BRACING IN PLACE OF SUPPORTING
SPRINKLER PIPING.
2. PIPING SHALL NOT CROSS SEISMIC JOINTS.
PIPE SLEEVES:
1. PIPES PASSING THROUGH CONCRETE OR MASONRY WALLS OR
CONCRETE FLOORS SHALL BE PROVIDED WITH PIPE SLEEVES
FITTED INTO PLACE AT THE TIME OF CONSTRUCTION. EACH
SLEEVE SHALL EXTEND THROUGH ITS RESPECTIVE WALL OR
FLOOR, AND BE CUT FLUSH WITH EACH SURFACE. UNLESS
OTHERWISE INDICATED, SLEEVES SHALL BE OF SUCH SIZE AS TO
PROVIDE A MINIMUM OF ¼ INCH ALL AROUND CLEARANCE
BETWEEN THE PIPE AND SLEEVE. SLEEVES IN BEARING WALLS
AND WET AREAS SHALL BE STEEL PIPE OR CAST IRON PIPE.
SLEEVES IN NONBEARING WALLS, FLOORS, OR CEILINGS MAY BE
STEEL PIPE, CAST IRON PIPE, OR GALVANIZED SHEET METAL WITH
LOCK-TYPE LONGITUDINAL SEAM.
2. WHERE PIPES PASS THROUGH FIRE WALLS, FIRE PARTITIONS, OR
FLOORS, A FIRE SEAL OF FIRE RESISTANT CAULK SHALL BE
PLACED BETWEEN THE PIPE AND SLEEVE.
WALL/FLOOR/CEILING ESCUTCHEONS:
1. ESCUTCHEONS SHALL BE PROVIDED AT ALL FINISHED SURFACES
WHERE EXPOSED PIPING PASSES THROUGH FLOORS, WALLS, OR
CEILINGS EXCEPT IN BOILER, UTILITY, OR EQUIPMENT ROOMS.
WHERE THE RISER INTO UPPER LEVEL MECHANICAL ROOMS
PENETRATES THE CONCRETE FLOOR, PROVIDE AND INSTALL A
MECHANICAL SEAL.
DRAINS AND DRIPS:
1. MAIN DRAIN: PROVIDE MAIN DRAIN ON SPRINKLER SYSTEM
APPROXIMATELY 4'-0" ABOVE FLOOR WITH 2" PIPE COMPLETE
WITH 2" UL LISTED ANGLE VALVE. DISCHARGE TO OUTSIDE IN
LOCATION, WHICH WILL NOT CAUSE DAMAGE.
2. ALL PIPING SHALL DRAIN BACK TO THE MAIN RISER. WHERE NOT
POSSIBLE, PROVIDE AUXILIARY DRAINS DISCHARGING TO
ARCHITECTURAL APPROVED LOCATIONS.
3. INSTALL AUXILIARY DRAINS AT ALL LOW POINTS IN SYSTEM. FIVE
OR FEWER TRAPPED HEADS WILL NOT REQUIRE DRAIN VALVE,
BUT MAY BE DRAINED THROUGH PLUGGED TEE. DRAIN VALVES TO
BE PIPED TO A SAFE PLACE OF DISCHARGE. VERIFY LOCATION OF
DRAINS WITH OWNER'S REPRESENTATIVE. ANY DRAIN NOT
DIRECTLY DISCHARGING TO A RECEPTACLE SHALL HAVE A ¾ INCH
HOSE LINE CONNECTION.
4. IF MAIN DRAINS, AUXILIARY DRAINS, OR INSPECTOR'S TEST
CONNECTIONS CANNOT BE SAFELY DISCHARGED DUE TO
PROPERTY DAMAGE, PROVIDE 18"X18" CONCRETE SPLASH
BLOCKS TO DEFLECT FLOW AND MINIMIZE DAMAGE.
PIPING MAINTENANCE AND PROTECTION REQUIREMENTS:
1. FLUSHING: FLUSHING ARRANGEMENTS SHALL BE PROVIDED BY
NFPA 13 IN ACCESSIBLE LOCATIONS.
2. FLUSHING CONNECTIONS: 11
4" NIPPLES WITH CAPS AT EXTREME
ENDS OF ALL CROSS MAINS.
A. ALL EARTHQUAKE BRACING TO BE IN ACCORDANCE WITH NFPA-13
OR CURRENT EDITION APPROVED BY LOCAL AHJ.
B. LISTED FLEXIBLE COUPLINGS SHALL ONLY BE INSTALLED WHERE
REQUIRED BY NFPA-13.
C. FLEXIBLE COUPLINGS SHALL BE LOCATED IN ACCORDANCE WITH
NFPA-13 AS FOLLOWS:
1. WITHIN 24" FROM THE TOP AND BOTTOM OF ALL RISERS.
2. WITHIN 12" ABOVE AND 24" BELOW FLOORS IN MULTISTORY
BUILDINGS.
3. WITHIN 1' OF ALL CONCRETE AND MASONARY WALL
PENETRATIONS UNLESS CLEARANCE IS PROVIDED BY
SECTION 9.3.4.
4. WITHIN 24" OF BUILDING EXPANSION JOINTS.
5. WITHIN 24" OF THE TOP OF DROPS EXCEEDING 15' IN LENGTH
TO PORTIONS OF SYSTEMS SUPPLYING MORE THAN ONE
SPRINKLER, REGARDLESS OF SIZE.
6. ABOVE AND BELOW ANY INTERMEDIATE POINTS OF SUPPORT
FOR A RISER OR OTHER VERTICAL PIPE.
7. AT THE FINAL CONNECTION POINT OF ALL HEADS IN A LAY-IN
OR HARD CEILING.
D. CLEARANCE SHALL BE PROVIDED AROUND ALL PIPING EXTENDING
THROUGH WALLS, FLOORS, PLATFORMS, AND FOUNDATIONS,
INCLUDING DRAINS, FDCS, AND OTHER AUXILIARY PIPING PER
SECTION 9.3.4 OR FLEXIBLE COUPLINGS SHALL BE PROVIDED.
E. LONGITUDINAL SWAY BRACING SPACED AT A MAXIMUM OF 80 FEET
SHALL BE PROVIDED FOR FEED AND CROSS MAINS AND NOT MORE
THAN 40 FEET FROM THE END.
F. TOPS OF RISERS OVER 3 FEET SHALL BE SECURED AGAINST
DRIFTING IN ANY DIRECTION USING A 4-WAY BRACE.
G. LATERAL SWAY BRACING SPACED AT A MAXIMUM OF 40 FEET
SHALL BE PROVIDED FOR FEED AND CROSS MAINS.
H. BRACING SHALL BE ATTACHED DIRECTLY TO FEED AND CROSS
MAINS.
I. THE LAST LENGTH OF PIPE AT THE END OF FEED OR CROSS MAINS
SHALL BE PROVIDED WITH A LATERAL BRACE. LATERAL BRACES
SHALL BE ALLOWED TO ACT AS A LONGITUDINAL BRACE IF THEY
ARE WITHIN 24" OF THE CETERLINE OF THE PIPING BRACED.
J. SWAY BRACING IS NOT REQUIRED FOR BRANCH LINES 2" AND
SMALLER.
K. THE END SPRINKLER ON EACH BRANCH LINE SHALL BE
RESTRAINED AGAINST EXCESSIVE MOVEMENT BY APPROVED
MEANS.
L. C-TYPE CLAMPS (INCLUDING BEAM AND LARGE FLANGE CLAMPS)
WITH OR WITHOUT RETAINING STRAPS, SHALL NOT BE USED TO
ATTACH BRACES TO THE BUILDING STRUCTURE.
M. ALL BEAM HANGERS SHALL BE EQUIPPED WITH RETAINER STRAPS.
SEISMIC BRACING NOTES
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:0 :1
P
M
FP0.1
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
FIRE PROTECTION NOTES
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
BJK/JTW
TJB
JTW
P
R E E
NI
GN
ELANOISSEF
O R R
EG
ISTERE
D
S
T A
TE OF ID
AH
O
WAVERE
K
TYD
O J
11076
UP
UP
DN
DN
UP
UP
MEDIUM
CONFERENCE
ROOM
ENTRY
VEST.
LARGE
MEETING
ROOM
STORAGE
105A
VESTIBULE/
BREAKOUT
FHP
OFFICE
FHP/BLM
STORAGE
FHP
OPEN
OFFICE
MENS
PUBLIC
RESTROOM
WOMENS
PUBLIC
RESTROOM
ELEC.
CLOS.
MENS
RESTROOM
WOMENS
RESTROOM
BREAKROOM
SMALL
CONFERENCE
ROOM /
LACTATION
ROOM
BLM
OPEN
OFFICE
BLM
OFFICE
BLM
OFFICE
BLM
OPEN
OFFICE
ELEV.
LOBBY
102 MAIL
ROOM
103A
RECEPTION
MEDIUM
CONFERENCE
ROOM
FMO
OPEN
OFFICE
BLM
OFFICE
BLM
OFFICE
BLM
OFFICE
BLM
OFFICE
FMO
OFFICE
CIO
OFFICE
PRIVACY
ROOM
BLM
STG.
VESTIBULE
LAW
OFFICE
(USFS)
LAW
OFFICE
(USFS)
LAW
OFFICE
(USFS)
LAW
EVIDENCE
ROOM
LAW
OFFICE
(BLM)
LAW
ENFORCEMENT
OPEN
OFFICE
CORRIDOR
113B
CORRIDOR
113C
CORRIDOR
113A
LOCATION OF FIRE DEPT.
CONNECTION AND HORN
STROBE
FWS
ASST.
STATE
SUPERINTENDENT
OFFICE
FWS
OFFICE
STORAGE
FWS
OFFICE
FWS
OFFICE
FWS
OPEN
OFFICE
NEPA
PLANNER
OPEN
OFFICE
ECO
OPEN
OFFICE
SMALL
CONFERENCE
ROOM
FWS
OFFICE
SECURITY
OFFICE
ECO
OFFICE
PUBLIC
AFFAIRS
OFFICER
HRM
OFFICE
VEG
OFFICE
TEC
OFFICE
NIZ
OFFICE
219 MEDIUM
CONFERENCE
ROOM
ROOM
BREAK
ROOM
MENS
RESTROOM
WOMENS
RESTROOM
ELEV
AQM
OPEN
OFFICE
DEPUTY
SUP.
OFFICE
SUPERVISORS
OFFICE
SUPERVISOR
FILING
MEDIUM
CONFERENCE
ROOM
EXECUTIVE
ASSISTANT/
WAITING
VEG
OPEN
OFFICE
TEC
OPEN
OFFICE
HRM
OPEN
OFFICE
NIZ
OPEN
OFFICE
LARGE
CONFERENCE
ROOM
CORRIDOR
210A
FIRE PROTECTION LEGEND
LIGHT HAZARD
ORDINARY HAZARD (GROUP 1)MECHANICAL
ROOM
BUILDING
STORAGE
ELEV.
FOYER
TEL/COMM
EMR
003A
0 1 2 3 4 5 6 7 8 9 10 inches
DRAWING NO.
PKG
NO.
SHEET
OF
PROJECT NO.:
REVISIONS:
DESIGNED
TECH. REVIEW
CADD
DESIGNED SUB SHEET NO. TITLE OF SHEET
/1
/2
:0 :2
P
M
FP2.1
06.01.18C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
FIRE PROTECTION PLANS
13083
INRC OFFICE BUILDING
PHASE 3
USDA FOREST SERVICE
BJK/JTW
TJB
JTW
: 1/16" = 1'-0"FP2.1
13 FIRST/GROUND LEVEL FIRE PROTECTION PLAN
: 1/16" = 1'-0"FP2.1E7.2
5 SECOND LEVEL FIRE PROTECTION PLAN
HYDRAULIC DESIGN AREA
ORDINARY HAZARD GROUP 1
0.15 GPM/1500 SF
AREA = 200 SF
SYSTEM TYPE: DRY
HYDRAULIC DESIGN AREA
LIGHT HAZARD
0.10 GPM/1500 SF
AREA = 1000 SF
SYSTEM TYPE: DRY
NOTE: - CEILING AIR PLENUM
ABOVE. PROVIDE CONCEALED
SPACE SPRINKLERS (DRY) AS
REQ'D. SEE ARCHITECTURAL
HYDRAULIC DESIGN AREA
LIGHT HAZARD
0.10 GPM/1500 SF
AREA = 1000 SF
SYSTEM TYPE: DRY
HYDRAULIC DESIGN AREA
LIGHT HAZARD
0.10 GPM/1500 SF
AREA = 14,000 SF
SYSTEM TYPE: WET
HYDRAULIC DESIGN AREA
ORDINARY HAZARD GROUP 1
0.15 GPM/1500 SF
AREA = 100 SF
SYSTEM TYPE: WET
HYDRAULIC DESIGN AREA
LIGHT HAZARD
0.10 GPM/1500 SF
AREA = 1000 SF
SYSTEM TYPE: DRY
: 1/16" = 1'-0"FP2.1
9 LOWER LEVEL FIRE PROTECTION PLAN
HYDRAULIC DESIGN AREA
ORDINARY HAZARD GROUP 1
0.15 GPM/1500 SF
AREA = 200 SF
SYSTEM TYPE: WET
HYDRAULIC DESIGN AREA
LIGHT HAZARD
0.10 GPM/1500 SF
AREA = 14,000 SF
SYSTEM TYPE: WET
HYDRAULIC DESIGN AREA
ORDINARY HAZARD GROUP 1
0.15 GPM/1500 SF
AREA = 100 SF
SYSTEM TYPE: WET
: 1/16" = 1'-0"FP2.1
7 ATTIC FIRE PROTECTION PLAN
HYDRAULIC DESIGN AREA
ORDINARY HAZARD GROUP 1
0.15 GPM/1500 SF
AREA = 100 SF
SYSTEM TYPE: DRY
NOTES:
1. SEE DETAIL 13/FP9.1 FOR ATTIC SPRINKLER PLACEMENT AND
COVERAGE REQUIREMENTS.
HYDRAULIC DESIGN AREA
ORDINARY HAZARD GROUP 1
0.15 GPM/1500 SF
AREA = 100 SF
SYSTEM TYPE: DRY
PROVIDE COMPLETE DRY SYSTEM
COVERAGE FOR ATTIC IN
ACCORDANCE WITH NFPA 13.
3 07.31.17
P
R E E
NI
GN
ELANOISSEF
O R R
EG
ISTERE
D
S
T A
TE OF ID
AH
O
WAVERE
K
TYD
O J
N.T.S.
N.T.S. N.T.S.
N.T.S. N.T.S.
N.T.S.
N.T.S.
4 43
8 10
6'- 0"
M
AX.
6'- 0"
M
AX.
10'-0" MAX.
"AP" COVERAGE "BB" SPAN
6'- 0"
M
AX.
6'- 0"
M
AX.
10'-0" MAX.
"AP" COVERAGE "BB" SPAN
6" MAX.
M A
X
M
IN
'-0
" M
IN
M A
X
M
IN
M
IN
6" MIN.
6'-0" MAX. - 4'-0" MIN.
7'-0" MIN. FOR "AP" - 6'-0" MIN. FOR STD.
6" M
IN.
4'-0" OR LESS 36
M
IN
. LESS THAN 6"
MORE THAN 4'-0" 36
M
IN
PIPE 2" & LARGER PIPE LESS THAN 2"
HANGER ROD SIZE PER
SCHEDULE
TURN BUCKLE (AS
REQUIRED)
HANGER ROD
CONNECT TO
STRUCTURE PER
APPLICABLE PIPE
SUPPORT DETAIL
PIPE W/
INSULATION
SHEET METAL
SADDLE INSERT
CLEVIS TYPE
HANGER
STRAP TYPE
HANGER
HANGER ROD SCHEDULE
HANGER SPACING CHART
PIPE
SIZE
DISTANCE BETWEEN HANGERS
STEEL
PIPE
CPVC
PIPE THINWALL
3/4" N/A 5'-6" N/A
1" 12'-0" 6'-0" 12'-0"
11/4" 12'-0" 6'-6" 12'-0"
11/2" 15'-0" 7'-0" 12'-0"
2" 15'-0" 8'-0" 12'-0"
21/2" 15'-0" 9'-0" 12'-0"
3" 15'-0" 10'-0" 12'-0"
4" 15'-0" N/A N/A
6" 15'-0" N/A N/A
4-WAY ADAPTER
QUICK
CLAMP
1"� SCHED. 40 PIPE
QUICK
CLAMP
SUPPORT STRUCTURE SUPPORT STRUCTURE
SPRINKLER PIPE
ANCHORAGEANCHORAGE
SPRINKLER PIPE
1"� SCHED. 40 PIPE
2-WAY SWAY BRACE 4-WAY SWAY BRACE
SCHED. 40 IRON
SPRINKLER PIPE
DROP-IN CEILING TILE
APPROVED SPRINKLER HEAD
APPROVED FITTING
BRANCH LINE
PIPE HANGER
DROP-IN CEILING TILE
APPROVED SPRINKLER HEAD
FLEXIBLE BRAIDED HOSE
APPROVED FITTING
BRANCH LINE
T-BAR SUPPORT
BRACKET
REDUCING OUTLET
SNAP CLAMP
2X8 WOOD
BLOCK
(3)-10D 3"
COMMON
NAILS
4-WAY ADAPTER
QUICK
CLAMP
1"� SCHED. 40 PIPE
QUICK
CLAMP
SPRINKLER PIPE SPRINKLER PIPE
1"� SCHED. 40 PIPE
2-WAY SWAY BRACE 4-WAY SWAY BRACE
(4)-10D, 3" COMMON
NAILS, CLINCHED
1/2" DIA. MACHINE
BOLT W/ WASHER,
CENTER IN BLOCK &
CINCH TIGHT
(18")-2X8 WOOD BLOCK
(4)-10D, 3" COMMON
NAILS, CLINCHED
1/2" DIA. MACHINE
BOLT W/ WASHER,
CENTER IN BLOCK &
CINCH TIGHT
(18")- 2X8 WOOD
BLOCK
1/2"� MACHINE
BOLT W/ WASHER
NOTE:
THERE IS AN ANTIFREEZE SYSTEM REMOTE FROM THE SYSTEM RISER (SEE
PLANS). MOUNT PLACARD ON THE SYSTEM RISER INDICATING: "1 REMOTE
ANTIFREEZE SYSTEM". MOUNT AN ADDITIONAL PLACARD ON THE ANTIFREEZE
SYSTEM MAIN VALVE INDICATING: SOLUTION, MANUFACTURER, CONCENTRATION,
AND VOLUME OF ANTIFREEZE USED IN THE SYSTEM.
*-IF APPLICABLE TO PROJECT
DUCTILE IRON UNDERGROUND SERVICE
(BY GENERAL CONTRACTOR).
SPRINKLER CONTRACTOR START OF WORK AT FLANGE
INSIDE BUILDING. EXTERIOR PIPING TESTED AND
FLUSHED BY OTHERS.
SYSTEM SIDE GAUGE.
2" DIA. PIPE STAND: ADJ. THREADED FLANGE, BOLTED
TO CONCRETE FLOOR
REDUCED PRESSURE BACKFLOW.
1/2" DIA. "AUXILIARY DRAIN" VALVE.
BUTTERFLY VALVE.
DRY PIPE VALVE: COMPLETE PRE-ASSEMBLED TRIM
PACKAGE: WATER SUPPLY CONTROL VALVE, AIR-PRESS.
SUPERVISORY SWITCH, ALARM PRESS. SWITCH.
RISER-MOUNTED OIL-LESS AIR COMPRESSOR.
120V/1-PH. 60HZ.
RISER MANIFOLD: FLOW SWITCH, TEST AND DRAIN
VALVE, PRESS. GAUGE, PRESS. RELIEF VALVE, 1/2" TEST
ORIFICE. "INSPECTORS TEST" AND "MAIN DRAIN"
GALV. TEST AND DRAIN PIPE.
SPARE HEAD CABINET: PROVIDE (2) EACH STYLE
SPRINKLER INSTALLED. PROVIDE APPROPRIATE WRENCH
FOR…