03.2 Drawing Civil Utility Ph3.pdf
PDF 1 MB Posted
- Attached to
- Repair Operations & Training Facility Federal contract opportunity
- Solicitation number
- W50S8H23B0001
About this file
This document provides details for a construction contract solicitation. The solicitation seeks bids to renovate a two-story 43,029 square foot Operations & Training Facility at the Niagara Falls International Airport in New York. The project magnitude is estimated between $10 million and $25 million. The North American Industry Classification code is 236220 for commercial and institutional building construction with a size standard of $45 million average annual revenue. The solicitation is set aside as an 8(a) small business competitive opportunity. The pre-bid conference and site visit are highly encouraged for parties intending to submit a bid. The solicitation and amendments will be posted on SAM.gov. Award will be made to the responsible bidder submitting the most advantageous bid based on price and price-related factors. Funding is not presently available but is anticipated to be secured by September 30, 2023. The project has been identified as a priority on the New York Army National Guard funding list contingent on available appropriations and bids within an awardable range. No award will be made without appropriated funds.
View the file
Other files for this federal contract opportunity
Show all 29
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RD
RD
RD
RD
RD
SAN
SAN
SAN
SAN
SAN
(Depth=1-3')
(Depth=1-3')
(Depth=2-3')
(Depth=2-3')
(Depth=1-3')
SAN SAN SAN SAN SAN
(Depth=1-3')
(Depth=1-3')
(Depth=1-3') (Depth=1-3')
(Depth=1-3')
(Depth=1-3')
GMTR
Gas Riser
Gas Riser
RD
RD
RD
RD
RD
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
ST
M
ST
M
RD
(Depth=2-3')
RD
(Depth=2-3') (Depth=2-3')
(Depth=2-3') (Depth=2-3')
(Depth=2-3')
ST
M
ST
M
ST
M
(Depth=2-3')
(Depth=2-3')
SAN
SAN
SAN
(Depth=2-3')(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
RD
RD RD
GMTR
(Depth=2-3')
(Depth=3-5')
SAN
SAN
SAN
SAN
SAN
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')(Depth=2-3')
(Depth=2-3')
RD
(Depth=2-3') (Depth=2-3')
Fib er
O pt ic
Fib er
O pt ic
Fiber Optic
Fiber O ptic
Fiber O ptic
Fiber O ptic
Fi be r O pt ic
Fiber Optic
Fi be r O pt ic
Fi be r O pt ic
Fiber O ptic
Fiber O ptic
(Depth=2-3')
(Depth=1-3')
(EOL)
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
RD
RD
RD
O O
X X X X X X X X X X X X X X X
Ebox
Rim-601.07
Generator
Ebox
Drain
Drain
Rim-601.22
Rim-601.14
O ve rh an g
O ve rh an g
RD
Elec. Panel
Shut-Off
BL#1
O ve rh an g
Rim-601.68
"Yield"
"Speed Limit 25"
"Yield"
Dashed Yellow Line
SA
N
SA
N
SA
N
SA
N
(Depth=5-7')
(Depth=5-7')
(Depth=5-7')
(Depth=3-5')
(Depth=3-5')
(Depth=2-3')
C O
M C
O M
(Depth=3-5')
(Depth=3-5')
(Depth=5-7')
(Depth=4-6')
PW PW PW PW PW PW PW
(Depth=3-5')
(Depth=5-7')
(Depth=1-2')
UE (Depth=3-5') (Depth=1-2')
(Depth=3-5')
XXX
X X
X X
X X
X
X
COM
COM
CO
M
COM
COM
COM
COM
COM
COM
Elec. Panel
Rim-600.62
Drain
O ve rh an g
Overhang
Overhang
Overhang
(Depth=5-7')
Overhang
(Depth=3-5')(Depth=2-3')
(Depth=2-3')
(Depth=5-7')
UE
UE
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
UE
UE
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M
COM COM
(Depth=2-3')
(Depth=2-3')
CO
M
C O
M
C O
M
C O
M
C O
M
STM
STM
COM
COM
COM
(Depth=2-3')
(Depth=2-3')
C O
M
C O
M
(Depth=5-6')
(Depth=2-3')
COM
COM COM COM
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
COM
"No Parking""No Parking"
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
Single Yellow Line
Rim-597.84
"Yield" "Yield"
XXXXXXXXXXXXXXXX
Eb ox
Rim-598.54
Single Yellow Line
PW PW PW PW PW PW PW PW PW PW PW PW PW
(Depth=3-5')
(Depth=3-5')
(Depth=3-5') (Depth=3-5') (Depth=3-5')
(Depth=3-5')
(Depth=3-5')
PW
PW
PW
PW
PW PW
(Depth=3-5')
(Depth=3-5')
(Depth=3-5')
Sign
Abandoned
COM
CO
M
COM
COM
COM
COM
COM
COM
COM
Shrub
Shrub
(Depth=3-5') (Depth=3-5')
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
(Depth=3-5')
(Depth=3-5')
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
UE
UE
G G
G
G G G G G G G G G G G G G G G G G G G G G G G G
G
G
G
G G
G G
G
G
PW
PW
PW
SD
SD
SD
SD
SD
SD
SD
UE
U
E
U E
UE
UE
UE
G G
UE UE UE UE
SD
PW PW PW
PW
PW
PW
PW PW PW PW PW
(Depth=3-4')
(Depth=3-4')
UE
UE
UE
UE UE UE UE UE UE UE UE UE UE UE UE UE
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3') (Depth=3-5')
(Depth=2-3')
(Depth=3-4')
CO
M
C O
M
CO
M
G G G
(Depth=2-3')
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
UE UE
UE
UE
UE
UE UE
C O
M
C O
M
C O
M
C O
M C
O M
(Depth=3-5')
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
(Depth=2-3') (Depth=2-3')
SD
SD
SD
SD
SD
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
GV
(Depth=4-5')
(Depth=4-5')
(Depth=4-5')
(Depth=3-5')
(Depth=1-2')
(Depth=1-2')
G G
G
PW
PW
PW
PW
(Depth=1-2')
(Depth=2-3')
(Depth=1-2')
(Depth=1-2')
(Depth=3-4')
COM COM COM COM
(Depth=2-3')
(Depth=3-5')
(Depth=3-5') (Depth=3-5')
SD
SD
SAN SAN SAN SAN SAN SAN SAN SAN
C Inv-592.44
8" PVC8" PVC
E Inv-592.10
W Inv-592.14 L
10" PVC
PV
C
8" P
VC
SW Inv-596.16
C Inv-595.78L
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M
UE
UE UE UE UE UE UE UE UE UE
UE
UE UE UE
Chiller Lines
(Depth=2-3') (Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=3-5')
(Depth=5-7')
(Depth=5-7')
SA
N
PV
C
Fl ow
Flow
Fl ow
12" PVC
6" PVC
NW Inv-596.21
C Inv-595.59L
SAN
12" PVCFlow
Flow
" P
VC
12" PVC
E Inv-591.46
SW Inv-591.52
W Inv-591.52
6" C
IP
8" PVC
10" VCP
10" VCP
N Inv-594.24
SE Inv-594.20
S Inv-598.74
W Inv-594.20
SAN
12" PVC
12" PVC
N Inv-593.72
W Inv-594.92
Flow
C Inv-592.02L
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SDSDSD
SD
SD
SD
SD
SD
SD
SD
SD
SD SD SD SD SD SD SD SD
SD SD
SD SD SD SD SD SD SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SDSDSD
2 Story Concrete Building
(EOL)
(EOL)
(EOWL)
(EOWL)
(EOWL)
SAN
SAN
SAN
SAN
C O
M C
O M
(EOL)
(En d n ot fou nd
(End not found)
SDSDSD
PE
P
PE
P
4" P
EP
12" PEP
4" PEP
12" PEP
4" PEP
SD SD SD
4" P
EP
4" PEP
4" P
EP
PE
P
PE
P
PE
P
4" PEP
12" PEP
4" P
EP
SAN SAN SAN SAN SAN
(shown per plans)
(shown per plans)
(shown per plans)
SD
6" C
IP
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
Xref \\SWITCHBLADE\Projects\FY19\1190117\08.OTHER DOCS\08.01.Owner Prov Info\Original Drawings\1190117_NYANG_NIAGARA_MEP_FP_v19 - Sheet - P-102 - PL-26552303-1290309- B-Floor Plan - Plumbing Supply Plan - 1st Floor EAST.dwg
1 2 3 4 5
A
B
C
D
100% SUBMITTAL
SHEET ID
N
EW
Y O
U R
A
IR
N
AT
IO
N
AL
G
AU
AR
D N
IA
G
AR
A
FA
LL
S
AI
R R
ES
ER
VE
S
TA
TI
O N
N
IA
G
AR
A
FA
LL
S, N
EW
Y O
R K
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
D
AT
E D
ES
C
R
IP
TI
O
N M
AR
K
ORIGINAL SHEET SIZE - ANSI D (22" X 34")
R
EN
O
VA
TE
O
PE
R
AT
IO
N S
AN
D
T R
AI
N
IN
G
FA
C
IL
IT
Y, B
U
IL
D
IN
G
N
EW
Y
O R
K
AI
R N
AT
IO
N
AL
G U
AR
D
N
IA
G
AR
A
FA
LL
S
AI
R
R
ES
ER
VE
S
TA
TI
O
N Q
PK
D
ES
IG
N
So ut h
Sa lin a St re et
Su ite
P
O B ox
Sy ra cu se , N
Y
-0
Q
PK
J
O B
P ar kw ay
L an e, S ui te
N or cr os s, G
A
Ph on e (6
) 3
-7
Fa x
(6
6-
P
O N
D J
O B#
: 1
- -08 M
AR
C
H
FI
LE
N
AM
E:
X
:\F Y2
1\
6\
.C
AD
B
IM
\0 4.
.C
AD
\C
U -1
.d w g
PL
O
TT
ED
: M on da y, M ar ch
6, M . R
U
TT
E
M . R
U
TT
E
P.
L
IN
G
LE
G . K
ER
R
CD102
U
TI
LI
TY
D
EM
O
LI
TI
O
N P
LA
N
GENERAL SHEET NOTES
1. THIS SHEET IS PART OF A MULTI-SHEET SET OF
CONSTRUCTION PLANS AND SHALL BE READ WITH
THE FULL SET TO BEST ENSURE PROPER
INTERPRETATION.
2. EXISTING CONDITIONS SHOWN ARE BASED UPON
PROVIDED INFORMATION. THE CONTRACTOR
SHALL VERIFY ALL EXISTING CONDITIONS,
INCLUDING HORIZONTAL AND VERTICAL
LOCATIONS OF EXISTING UTILITIES PRIOR TO
CONSTRUCTION.
SHEET KEYNOTES
1. DEMOLISH MANHOLE
2. DEMOLISH STORM SEWER LINE
3. DEMOLISH WATER LINE
4. DEMOLISH UNDERGROUND ELECTRIC
5. DEMOLISH SANITARY SEWER LINE
6. DEMOLISH CLEANOUT
7. REMOVE SHRUBS
LEGEND:
SCALE: 1" = 20' 0 20' 40' 60'10'A1 UTILITY DEMOLITION PLAN
DEMOLISH UTILITY LINE
C U
-1
.D W
G
REMOVE / DEMOLISH SHRUBS
SAN
SAN
SAN
SAN
SAN
(Depth=1-3')
(Depth=1-3')
(Depth=2-3')
(Depth=2-3')
(Depth=1-3')
SAN SAN SAN SAN SAN
(Depth=1-3')
(Depth=1-3')
(Depth=1-3') (Depth=1-3')
(Depth=1-3')
(Depth=1-3')
GMTR
Gas Riser
Gas Riser
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
(Depth=2-3')
(Depth=2-3') (Depth=2-3')
(Depth=2-3') (Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
SAN
SAN
SAN
(Depth=2-3')(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
GMTR
(Depth=2-3')
(Depth=3-5')
SAN
SAN
SAN
SAN
SAN
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')(Depth=2-3')
(Depth=2-3')
(Depth=2-3') (Depth=2-3')
Fib er
O pt ic
Fib er
O pt ic
Fiber Optic
Fiber O ptic
Fiber O ptic
Fiber O ptic
Fi be r O pt ic
Fiber Optic
Fi be r O pt ic
Fi be r O pt ic
Fiber O ptic
Fiber O ptic
(Depth=2-3')
(Depth=1-3')
(EOL)
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
O O
X X X X X X X X X X X X X X X
Ebox
Rim-601.07
Generator
Ebox
Drain
Drain
Rim-601.22
Rim-601.14
O ve rh an g
O ve rh an g
RD
Elec. Panel
Shut-Off
BL#1
O ve rh an g
Rim-601.68
"Yield"
"Speed Limit 25"
"Yield"
Dashed Yellow Line
SA
N
SA
N
SA
N
SA
N
(Depth=5-7')
(Depth=5-7')
(Depth=5-7')
(Depth=3-5')
(Depth=3-5')
(Depth=2-3')
C O
M C
O M
(Depth=3-5')
(Depth=3-5')
(Depth=5-7')
(Depth=4-6')
PW PW PW PW PW PW PW
(Depth=3-5')
(Depth=5-7')
(Depth=1-2')
UE (Depth=3-5') (Depth=1-2')
(Depth=3-5')
XXX
X X
X X
X X
X
X
COM
COM
CO
M
COM
COM
COM
COM
COM
COM
Elec. Panel
Rim-600.62
Drain
O ve rh an g
Overhang
Overhang
Overhang
(Depth=5-7')
Overhang
(Depth=3-5')(Depth=2-3')
(Depth=2-3')
(Depth=5-7')
UE
UE
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
UE
UE
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M
COM COM
(Depth=2-3')
(Depth=2-3')
CO
M
C O
M
C O
M
C O
M
C O
M
COM
COM
COM
C O
M
C O
M
(Depth=5-6')
(Depth=2-3')
COM
COM COM COM
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
COM
"No Parking""No Parking"
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
Single Yellow Line
Rim-597.84
"Yield" "Yield"
XXXXXXXXXXXXXXXX
Eb ox
Rim-598.54
Single Yellow Line
PW PW PW PW PW PW PW PW PW PW PW PW PW
(Depth=3-5')
(Depth=3-5')
(Depth=3-5') (Depth=3-5') (Depth=3-5')
(Depth=3-5')
(Depth=3-5')
PW
PW
PW
PW
PW PW
(Depth=3-5')
(Depth=3-5')
(Depth=3-5')
Sign
Abandoned
COM
CO
M
COM
COM
COM
COM
COM
COM
COM
(Depth=3-5') (Depth=3-5')
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
(Depth=3-5')
(Depth=3-5')
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
PW
UE
UE
G G
G
G G G G G G G G G G G G G G G G G G G G G G G G
G
G
G
G G
G G
G
G
SD
SD
SD
SD
SD
SD
SD
UE
U
E
U E
UE
UE
UE
G G
UE UE UE UE
SD
PW PW PW
PW
PW
PW
PW PW PW PW PW
(Depth=3-4')
(Depth=3-4')
UE
UE
UE
UE UE UE UE UE UE UE UE UE UE UE UE UE
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=2-3') (Depth=3-5')
(Depth=2-3')
(Depth=3-4')
CO
M
C O
M
CO
M
G G G
(Depth=2-3')
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
UE UE
UE
UE
UE
UE UE
C O
M
C O
M
C O
M
C O
M C
O M
(Depth=3-5')
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
(Depth=2-3') (Depth=2-3')
SD
SD
SD
SD
SD
(Depth=2-3')
(Depth=2-3')
(Depth=2-3')
GV
(Depth=4-5')
(Depth=4-5')
(Depth=4-5')
(Depth=3-5')
(Depth=1-2')
(Depth=1-2')
G G
G
PW
PW
PW
PW
(Depth=1-2')
(Depth=2-3')
(Depth=1-2')
(Depth=1-2')
(Depth=3-4')
COM COM COM COM
(Depth=2-3')
(Depth=3-5')
(Depth=3-5') (Depth=3-5')
SD
SD
SAN SAN SAN SAN SAN SAN SAN SAN
C Inv-592.44
8" PVC8" PVC
E Inv-592.10
W Inv-592.14 L
SW Inv-596.16
C Inv-595.78L
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M
UE
UE UE UE UE UE UE UE UE UE
UE
UE UE UE
Chiller Lines
(Depth=2-3') (Depth=2-3')
(Depth=2-3')
(Depth=2-3')
(Depth=3-5')
(Depth=5-7')
(Depth=5-7')
SA
N
PV
C
Fl ow
Fl ow
12" PVC
6" PVC
NW Inv-596.21
C Inv-595.59L
SAN
12" PVCFlow
Flow
" P
VC
12" PVC
E Inv-591.46
SW Inv-591.52
W Inv-591.52
6" C
IP
8" PVC
10" VCP
10" VCP
N Inv-594.24
SE Inv-594.20
S Inv-598.74
W Inv-594.20
SAN
12" PVC
12" PVC
N Inv-593.72
W Inv-594.92
Flow
C Inv-592.02L
2 Story Concrete Building
(EOL)
(EOL)
(EOWL)
(EOWL)
(EOWL)
SAN
SAN
SAN
SAN
C O
M C
O M
(EOL)
(En d n ot fou nd
(End not found)
SAN SAN SAN SAN SAN
(shown per plans)
(shown per plans)
(shown per plans)
SD
6" C
IP
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD SD SD SD SD SD
SD
SD SD SD SD SD SD SD
SD
SD
SD
SD
SD
SD
SDSDSD
SD
SD
SD
W F
SS
SS
S
EX- B
CO
CO B.2
SS
4" PVC
CO
CO D.2
CO
CO D.1
6" PVC
CO
CO D
CO
CO D.3
SS
6" PVC
CO
CO C.3
SS
6" PVC
CO
CO A.1
4" PVC
6" PVC
S
SSMH A
6" PVC
6" PVC
6" PVC
S
SSMH C
SS
COCO B.1
" P
VC
6" PVC
CO
1 2 3 4 5
A
B
C
D
100% SUBMITTAL
SHEET ID
N
EW
Y O
U R
A
IR
N
AT
IO
N
AL
G
AU
AR
D N
IA
G
AR
A
FA
LL
S
AI
R R
ES
ER
VE
S
TA
TI
O N
N
IA
G
AR
A
FA
LL
S, N
EW
Y O
R K
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
D
AT
E D
ES
C
R
IP
TI
O
N M
AR
K
ORIGINAL SHEET SIZE - ANSI D (22" X 34")
R
EN
O
VA
TE
O
PE
R
AT
IO
N S
AN
D
T R
AI
N
IN
G
FA
C
IL
IT
Y, B
U
IL
D
IN
G
N
EW
Y
O R
K
AI
R N
AT
IO
N
AL
G U
AR
D
N
IA
G
AR
A
FA
LL
S
AI
R
R
ES
ER
VE
S
TA
TI
O
N Q
PK
D
ES
IG
N
So ut h
Sa lin a St re et
Su ite
B ox
Sy ra cu se , N
Y
-0
Q
PK
J
O B
P ar kw ay
L an e, S ui te
N or cr os s, G
A
Ph on e (6
) 3
-7
Fa x
(6
6-
P
O N
D J
O B#
: 1
- -08 M
AR
C
H
FI
LE
N
AM
E:
X
:\F Y2
1\
6\
.C
AD
B
IM
\0 4.
.C
AD
\C
U -1
.d w g
PL
O
TT
ED
: M on da y, M ar ch
6, M . R
U
TT
E
M . R
U
TT
E
P.
L
IN
G
LE
G . K
ER
R
C-110
U
TI
LI
TY
P
LA
N
GENERAL SHEET NOTES
1. THIS SHEET IS PART OF A MULTI-SHEET SET OF
CONSTRUCTION PLANS AND SHALL BE READ WITH
THE FULL SET TO BEST ENSURE PROPER
INTERPRETATION.
2. REFER TO PIPE PROFILES ON SHEET C-201 FOR
FURTHER INFORMATION ON SANITARY SEWER
PIPE SIZES, MATERIALS, AND SLOPES, AND FOR
FURTHER INFORMATION ON STRUCTURE TYPES
AND ELEVATIONS.
3. ALL UTILITY CONSTRUCTION SHALL MEET ALL
APPLICABLE REQUIREMENTS AND REGULATIONS
OF THE NIAGARA COUNTY.
4. EXISTING CONDITIONS SHOWN ARE BASED UPON
PROVIDED INFORMATION. THE CONTRACTOR
SHALL VERIFY ALL EXISTING CONDITIONS,
INCLUDING HORIZONTAL AND VERTICAL
LOCATIONS OF EXISTING UTILITIES PRIOR TO
CONSTRUCTION.
5. REFER TO PIPE BEDDING DETAIL C1/C-502.
6. EMPLOY EROSION CONTROL MEASURES THAT
MINIMIZE DISTURBANCE AND ELIMINATE THE
POSSIBILITY OF SEDIMENT-LADEN RUNOFF BEING
DISCHARGED FROM THE SITE.
SHEET KEYNOTES
1. NEW CLEANOUT. (TYPICAL) (SEE DETAIL
A1/C-502)
2. TIE INTO EXISTING MANHOLE WITH CORE
AND BOOT.
3. NEW MANHOLE. (TYPICAL) (SEE DETAIL
A3/C-502)
4. SEE PLUMBING PLANS FOR CONTINUATION.
5. DOGHOUSE MANHOLE. (SEE DETAIL
A4/C-502)
6. REPLACE EXISTING 4" WATER LINE WITH
WITH NEW 2 1/2" PVC WATER LINE .
7. NEW C900 6" FIRE SERVICE LINE.
8. NEW GATE VALVE.
9. TAPPING SLEEVE AND VALVE.
10. SEE FIRE PROTECTION PLAN FOR
CONTINUATION.
LEGEND:
SS
SANITARY MANHOLE
(DETAIL A3/C-501)
S
CO CLEANOUT (DETAIL A1/C-501)
SCALE: 1" = 20' 0 20' 40' 60'10'A1 UTILITY PLAN
NEW SANITARY SEWER LINE.
4 4
NEW WATER LINE.
NEW FIRE SERVICE LINE
4 10
C U
-1
.D W
G
ELEVATIO
N
EL
EV
AT
IO
N
STATION
SANITARY SEWER D.2-EX-B PROFILE
HORZ. SCALE 1"= 20'
VERT. SCALE 1"= 5'
0+00 0+50 1+00 1+50
ELEVATIO
N
EL
EV
AT
IO
N
STATION
SANITARY SEWER D.3-D PROFILE
HORZ. SCALE 1"= 20'
VERT. SCALE 1"= 5'
EX
- B
TO
P:
.0 7'
IE
IN
.7
3' (B
.1
IE
O
U T
5.
6" PVC
38LF @ 0.70%
6" PVC
50LF @ 0.70% 6" PVC
18LF @ 0.70%
6" PVC
8LF @ 0.70%
4" PVC
5LF @ 1.00%
ELEVATIO
N
EL
EV
AT
IO
N
STATION
SANITARY SEWER B.1 - B.2 PROFILE
HORZ. SCALE 1"= 20'
VERT. SCALE 1"= 5'
ELEVATIO
N
EL
EV
AT
IO
N
STATION
SANITARY SEWER C.3 - C.1 PROFILE
HORZ. SCALE 1"= 20'
VERT. SCALE 1"= 5'
0+00 0+50
C O
D
TO
P:
.2
0'
IE
IN
.6 7'
(D .1
IE
IN
.6 7'
(D .3
IE
IN
.6 7'
(B
LD
G -1
IE
O U
T
6.
C
6" PVC
41LF @ 0.93%
C O
D .3
TO
P:
.9 4'
IE
IN
.6
5' (B
LD
G
-2
IE
O
U T
7.
D
4" PVC
2LF @ 1.00%
CONTRACTOR TO FIELD
VERIFY THE DEPTH AND
INVERT OF EXISTING
SANITARY LINE, AND
REPORT FINDINGS TO
ENGINEER PRIOR TO
CONSTRUCTION.
SEE PLUMBING
FOR
CONTINUATION
TO BUILDING
EXISTING
GRADE
EXISTING
BUILDING
AP
PR
O
XI
M
AT
E
LO
C
AT
IO
N
O F
U N
D
ER
G R
O U
N D
F
IB
ER
O
PT
IC
L
IN
E
AP
PR
O
XI
M
AT
E
LO
C
AT
IO
N
O F
U N
D
ER
G R
O U
N D
F
IB
ER
O
PT
IC
L
IN
E
AP
PR
O
XI
M
AT
E
LO
C
AT
IO
N
O F
U N
D
ER
G R
O U
N D
EL
EC
TR
IC
L
IN
E
EXISTING
BUILDINGEXISTING
GRADE
SEE PLUMBING
FOR
CONTINUATION
TO BUILDING
ELEVATIO
N
EL
EV
AT
IO
N
STATION
SANITARY SEWER A.1-A PROFILE
HORZ. SCALE 1"= 20'
VERT. SCALE 1"= 5'
0+00 0+50
SS
M
H A
TO
P:
.0 2'
IE
IN
.8
6' (A
.1
IE
IN
.8
6' (E
X
" V C
P
IN
IE
O U
T
4.
EX
0" V
C P
O U
T)
6" PVC
25LF @ 1.00%
C O
A .1
TO
P:
.9 4'
IE
IN
.1
1' (B
LD
G
-6
IE
O
U T
5.
A)
4" PVC
7LF @ 1.00%
EXISTING
BUILDINGEXISTING
GRADE
SEE PLUMBING
FOR CONTINUATION
TO BUILDING
AP
PR
O
XI
M
AT
E
LO
C
AT
IO
N
O F
U N
D
ER
G R
O U
N D
F
IB
ER
O
PT
IC
L
IN
E
SS
M
H C
TO
P:
.4 8'
IE
IN
.3
2' (D
IE
IN
.3 2'
(C .3
IE
O U
T
6.
B.
1)
C O
B .1
TO
P:
.6 7'
IE
IN
.9
5' (C
IE
IN
.9 5'
(B .2
IE
O U
T
5.
B)
6" PVC
31LF @ 0.70%
C O
D
TO
P:
.2
0'
IE
IN
.6 7'
(D .1
IE
IN
.6 7'
(D .3
IE
IN
.6 7'
(B
LD
G -1
IE
O U
T
6.
C
C O
D .1
TO
P:
.2 5'
IE
IN
.8
0' (D
.2
IE
O
U T
6.
D
C
O D
.2
TO
P:
.3
5'
IE
IN
.8 5'
IE
O U
T
6.
D .1
" H
D
PE
S
TO
R M
S
EW
ER
0+00 0+50
EXISTING
BUILDING
SS
M
H C
TO
P:
.4 8'
IE
IN
.3
2' (D
IE
IN
.3 2'
(C .3
IE
O U
T
6.
B.
1)
6" PVC
36LF @ 0.95%
C O
C .3
TO
P:
.9 5'
IE
IN
.6
6' (B
LD
G
-5
IE
O
U T
6.
C
4" PVC
8LF @ 1.00%
EXISTING
GRADE
AP
PR
O
XI
M
AT
E
LO
C
AT
IO
N
O F
U N
D
ER
G R
O U
N D
F
IB
ER
O
PT
IC
L
IN
E
8" H
D
PE
S
TO
R M
S
EW
ER
0+00
C O
B .2
TO
P:
.1 1'
IE
IN
.3
3' (B
LD
G
-4
IE
O
U T
6.
B.
1)
C O
B .1
TO
P:
.6 7'
IE
IN
.9
5' (C
IE
IN
.9 5'
(B .2
IE
O U
T
5.
B)
6" PVC
18LF @ 2.09%
SEE PLUMBING
FOR CONTINUATION
TO BUILDING
SEE PLUMBING
FOR CONTINUATION
TO BUILDING
EXISTING
GRADE
EXISTING
BUILDING
8" H
D
PE
S
TO
R M
S
EW
ER
" H
D
PE
S
TO
R M
S
EW
ER
CONTRACTOR TO FIELD
VERIFY THE DEPTH AND
INVERT OF EXISTING
SANITARY LINE, AND
REPORT FINDINGS TO
ENGINEER PRIOR TO
CONSTRUCTION.
1 2 3 4 5
A
B
C
D
100% SUBMITTAL
SHEET ID
N
EW
Y O
U R
A
IR
N
AT
IO
N
AL
G
AU
AR
D N
IA
G
AR
A
FA
LL
S
AI
R R
ES
ER
VE
S
TA
TI
O N
N
IA
G
AR
A
FA
LL
S, N
EW
Y O
R K
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
D
AT
E D
ES
C
R
IP
TI
O
N M
AR
K
ORIGINAL SHEET SIZE - ANSI D (22" X 34")
R
EN
O
VA
TE
O
PE
R
AT
IO
N S
AN
D
T R
AI
N
IN
G
FA
C
IL
IT
Y, B
U
IL
D
IN
G
N
EW
Y
O R
K
AI
R N
AT
IO
N
AL
G U
AR
D
N
IA
G
AR
A
FA
LL
S
AI
R
R
ES
ER
VE
S
TA
TI
O
N Q
PK
D
ES
IG
N
So ut h
Sa lin a St re et
Su ite
B ox
Sy ra cu se , N
Y
-0
Q
PK
J
O B
P ar kw ay
L an e, S ui te
N or cr os s, G
A
Ph on e (6
) 3
-7
Fa x
(6
6-
P
O N
D J
O B#
: 1
- -08 M
AR
C
H
FI
LE
N
AM
E:
X
:\F Y2
1\
6\
.C
AD
B
IM
\0 4.
.C
AD
\C
U -1
.d w g
PL
O
TT
ED
: M on da y, M ar ch
6, M . R
U
TT
E
M . R
U
TT
E
P.
L
IN
G
LE
G . K
ER
R
C-201
SA
N
IT
AR
Y
SE
W
ER
P R
O
FI
LE
S
LEGEND:
SANITARY MANHOLE
(DETAIL A3/C-501)
CLEANOUT (DETAIL A1/C-501)C0
MH
NOTES:
1. EXISTING CONDITIONS SHOWN ARE BASED
UPON PROVIDED INFORMATION. THE
CONTRACTOR SHALL VERIFY ALL EXISTING
CONDITIONS, INCLUDING HORIZONTAL AND
VERTICAL LOCATIONS OF EXISTING UTILITIES
PRIOR TO CONSTRUCTION.
2. CONTRACTOR TO VERIFY ELEVATIONS OF
SANITARY SEWER PIPING EXITING THE
BUILDING AND COORDINATE WITH DESIGN
PROFILES. DISCREPANCIES SHOULD BE
BROUGHT TO THE ATTENTION OF THE COR.
C U
-1
.D W
G
1 2 3 4 5
A
B
C
D
100% SUBMITTAL
SHEET ID
N
EW
Y O
U R
A
IR
N
AT
IO
N
AL
G
AU
AR
D N
IA
G
AR
A
FA
LL
S
AI
R R
ES
ER
VE
S
TA
TI
O N
N
IA
G
AR
A
FA
LL
S, N
EW
Y O
R K
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
D
AT
E D
ES
C
R
IP
TI
O
N M
AR
K
ORIGINAL SHEET SIZE - ANSI D (22" X 34")
R
EN
O
VA
TE
O
PE
R
AT
IO
N S
AN
D
T R
AI
N
IN
G
FA
C
IL
IT
Y, B
U
IL
D
IN
G
N
EW
Y
O R
K
AI
R N
AT
IO
N
AL
G U
AR
D
N
IA
G
AR
A
FA
LL
S
AI
R
R
ES
ER
VE
S
TA
TI
O
N Q
PK
D
ES
IG
N
So ut h
Sa lin a St re et
Su ite
B ox
Sy ra cu se , N
Y
-0
Q
PK
J
O B
P ar kw ay
L an e, S ui te
N or cr os s, G
A
Ph on e (6
) 3
-7
Fa x
(6
6-
P
O N
D J
O B#
: 1
- -08 M
AR
C
H
FI
LE
N
AM
E:
X
:\F Y2
1\
6\
.C
AD
B
IM
\0 4.
.C
AD
\C
U -1
.d w g
PL
O
TT
ED
: M on da y, M ar ch
6, M . R
U
TT
E
M . R
U
TT
E
P.
L
IN
G
LE
G . K
ER
R
C-502
SI
TE
D
ET
AI
LS6" DIP LINE
PLUG IF LINE DOES
DIRECTION OF FLOW
NOT CONTINUE
45° DIP BEND
FINISHED
GRADE
UNLESS CLEANOUT IS IN
12"X12"X6" DEEP CONC. PAD
VARIES
CONC. PAVEMENT
BRASS COUNTERSUNK
CLEANOUT PLUG
DIP WYE
A1 SANITARY SEWER CLEANOUT
NO SCALE
16" TO 21"
"D"
PIPE DIA
TAKEN AT TOP OF PIPE
MAXIMUM TRENCH WIDTH "W"
18" 15" 12" 10" 8"
48" & LARGER
33" TO 42"
24" TO 30"
6" TO 15"
"A"
MAXIMUM
AODA
W
D
UNDISTURBED
BEDDING MATERIAL
SOIL (TYP.)
PIPE O.D./2
PIPE O.D.
(4" MIN.)
C1 PIPE BEDDING
NO SCALE
NOTE
PROVIDE BEDDING IN ACCORDANCE WITH SPECIFICATIONS
FOR MATERIALS AND COMPACTION FOR TRENCH BACKFILL
A3 PRECAST SANITARY SEWER MANHOLE
NO SCALE
GRADE RINGS AS REQUIRED.
1' SECTION IF LESS THAN
STEPS
6" (MIN) BEDDING
MEETING AASH TO
M294, #7 STONE.
58" (MIN.)
AS
R
EQ
D
" S
EC
TI
O
N S
8" (S
TD
VA
R
IA
BL
E
LE
N G
TH
S
6" MIN.
A
VA
IL
AB
LE
5"
4' AS REQD.
5" (MIN.)
PIPE INVERT
GROUT TO
FLOW
48" DIA.
(T
YP
REINFORCED STEEL
FINISHED GRADE
24" DIA. FRAME
AND COVER OR GRATE
24"
DIA.
SECTION
ECCENTRIC CONE
NOTES
1. FOR MANHOLES IN TURFED AREA OR SUBJECT TO LIGHT
TRAFFIC ONLY, FRAMES AND COVERS SHALL HAVE A MINIMUM
COMBINED WEIGHT OF 400 LBS.
2. IN LOCATIONS SUBJECT TO HEAVY TRAFFIC THE MH, FRAME
AND COVER OR GRATING SHALL BE RATED FOR HS-20 LOADING.
3. CONCRETE OR GROUT CHANNEL SHALL BE FORMED BETWEEN
INVERTS OF ALL INCOMING AND OUTGOING PIPES.
MANHOLE WALL 6"
W = 5'-10"
FOR LEVELING
1"/1'
UNDISTURBED EARTH
4000 PSI CONCRETE
MIN. THICKNESS
6"
CUT AND REMOVE TOP
HALF OF EXISTING PIPE
NOTE:
CONSTRUCTED OVER EXISTING PIPE
TYPICAL DETAIL AT MANHOLE
6" COMPACTED
CRUSHED STONE
6" MIN
IN WET CONDITIONS ATTACH
PIPE INSIDE OF MANHOLE.
NEW PIPE INTO MH
WITH RUBBER BOOT CONNECTION
A4 DOGHOUSE MANHOLE
NO SCALE
C U
-1
.D W
G
| CD102 UTILITY DEMOLITION PLAN |
| C-110 UTILITY PLAN |
| C-201 SANITARY SEWER PROFILES |
| C-502 SITE DETAILS |
File details come from the government source that posted it. Updated .