03.09 Drawing Mechanical Ph3.pdf

PDF 17 MB Posted

Attached to
Repair Operations & Training Facility Federal contract opportunity
Solicitation number
W50S8H23B0001
Issued by
Department of the Army New York Army National Guard

About this file

This document outlines a federal construction contract solicitation. The solicitation seeks bids for Project #08-2001 to renovate a 43,029 square foot operations and training facility at Niagara Falls International Airport in New York. The project magnitude is estimated between $10 million and $25 million. A pre-bid conference and site visit are encouraged for all interested bidders. The North American Industry Classification code is 236220 and the size standard for small businesses is $45 million in average annual revenue for the past three years. This is being solicited as a competitive 8(a) small business set-aside. Award will be made to the responsible bidder submitting the most advantageous bid based on price and price-related factors. Funds are not currently available but are anticipated to become available by September 30, 2023. No contract will be awarded until funds are appropriated. The soliciting agency is the Department of the Army New York Army National Guard.

View the file

Other files for this federal contract opportunity

Other files attached to Repair Operations & Training Facility, newest first.
File Type Posted
C4 Abstract OF1419.pdf PDF
C4 Bid Opening Sign-In.pdf PDF
Consolidated RFI List.xlsx XLSX spreadsheet
B6 Hazardous Material Report.pdf PDF
B8 W50S8H-23-B-0001 IFB-P00001.pdf PDF
B8 W50S8H-23-B-0001 IFB-P00001 Amend.pdf PDF
B7 Site Visit Sign-In.pdf PDF
B7 Pre-Bid Conference Slides Final.pptx PPTX presentation
01.3 Drawing Mechanical Ph1.pdf PDF
03.1 Drawing Civil Storm Ph3.pdf PDF
03.3 Drawing Structural Ph3.pdf PDF
03.7 Drawing Fire Alarm Ph3.pdf PDF
03.10 Drawing Electrical Ph3.pdf PDF
H8 Specs.pdf PDF
01.1 Drawing Architectural Ph1.pdf PDF
01.4 Drawing Electrical Ph1.pdf PDF
02.2 Drawing Architectural Ph2.pdf PDF
03.08 Drawing Plumbing Ph3.pdf PDF
01.2 Drawing Plumbing Ph1.pdf PDF
02.1 Drawing Architectural Demo Ph2.pdf PDF
03.2 Drawing Civil Utility Ph3.pdf PDF
03.4 Drawing Architectural Demo Ph3.pdf PDF
03.6 Drawing Fire Protection Ph3.pdf PDF
03.11 Drawing Telecom Ph3.pdf PDF
03.12 Drawing Reference Drawings Ph3.pdf PDF
A2 JA FAR Part 6 Advantor SAM Post.pdf PDF
B8 W50S8H-23-B-0001 IFB.pdf PDF
01.0 Drawing General.pdf PDF
03.5 Drawing Architectural Ph3.pdf PDF
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL MECHANICAL NOTES

1. INSTALLATION OF HVAC WORK SHALL BE COORDINATED WITH OTHER TRADES BEFORE ANY

INSTALLATION IS MADE. DUCTWORK SHOWN ON PLANS IS SCHEMATIC. DUCTWORK SHALL BE

INSTALLED TIGHT TO STRUCTURE. ALL TRANSITIONS, ELBOWS, ETC. REQUIRED TO AVOID

CONFLICTS & MAXIMIZE CEILING HEIGHTS. EQUIPMENT, PIPING OR DUCTWORK INTERFERING WITH

OTHER TRADES SHALL BE RELOCATED AS REQUIRED AT NO ADDITIONAL COST TO THE OWNER.

2. COORDINATE MECHANICAL AND ELECTRICAL SUCH THAT MECHANICAL PIPING, DUCTWORK AND

EQUIPMENT IS NOT LOCATED OVER OR ABOVE ANY ELECTRICAL, COMMUNICATIONS, OR DATA

EQUIPMENT.

3. AT START OF CONSTRUCTION PREPARE TYPED LISTS OF EQUIPMENT THAT ARE SUPPLIED

REQUIRING ELECTRICAL WORK, AND SEND LISTS TO THE ELECTRICAL CONTRACTOR FOR REVIEW

AND COORDINATION.

4. WRITTEN DIMENSIONS ON DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.

5. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S APPROVED

CLEARANCE, UFC, AND IBC/IMC.

6. INSTALLATION OF EQUIPMENT SHALL PERMIT ACCESSIBILITY FOR SERVICE AND/OR

REPLACEMENT WITHOUT NECESSITATING REMOVAL OR MODIFICATION TO OTHER PIPING, WIRING, OR EQUIPMENT.

7. CEILING-MOUNTED EQUIPMENT SHALL BE INSTALLED IN SUCH A MANNER THAT LIGHTS, PIPING, DUCTWORK, ETC., DO NOT BLOCK ACCESS TO EQUIPMENT AND RELATED ACCESSORIES.

8. COORDINATE WALL, FLOOR AND ROOF PENETRATIONS WITH THE GENERAL CONTRACTOR.

9. CAULK WITH SILICONE ALL GAPS BETWEEN WALL, CEILING AND FLOOR OPENINGS AND HVAC

EQUIPMENT PENETRATIONS. PATCH LARGE GAPS BEFORE CAULKING IS APPLIED.

10. SUPPLEMENTAL STEEL MEMBERS REQUIRED TO SUPPORT HVAC EQUIPMENT FROM MAIN

STRUCTURE SHALL BE PROVIDED BY THE HVAC CONTRACTOR UNLESS SPECIFICALLY NOTED

OTHERWISE. REFER TO STRUCTURAL DRAWINGS AND SPECIFICATIONS FOR CONSTRUCTION

TYPES. PROCURE AND INSTALL UPON APPROVAL FROM CONTRACTING OFFICER. PROVIDE

STRUCTURAL STEEL SUPPORT SUBMITTAL TO ENGINEER OF RECORD FOR REVIEW.

11. DUCTWORK AIR DISTRIBUTION SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA

STANDARDS AND THE PRESSURE CLASSIFICATION OF EACH INDIVIDUAL DUCTWORK SYSTEM, NO

LESS THAN 2 IN.W.G., SEAL CLASS A (LEAKAGE CLASS 6, OR 4% OF THE TOTAL AIR FLOW

THROUGH THE DUCT). DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS.

12. VOLUME DAMPERS SHALL BE PROVIDED AT EACH NEW MAIN BRANCH TAKE-OFF AND IN SUCH

OTHER LOCATIONS WHERE REQUIRED TO PROPERLY BALANCE THE SYSTEM.

13. INSTRUMENT TEST HOLES SHALL BE PROVIDED IN AIR DISTRIBUTION SYSTEMS WHEREVER

VOLUME DAMPERS ARE SHOWN.

14. SQUARE ELBOWS SHALL ONLY BE USED WHERE SPACE LIMITATIONS PREVENT USE OF 1.5 RADIUS ELBOW AND ONLY UPON APPROVAL OF CONTRACTING OFFICER. PROVIDE TURNING VANES IN ALL

45° AND 90° SQUARE ELBOWS. TURNING VANES SHALL BE SINGLE THICKNESS TYPE WITHOUT

RAILING EDGE. IF TURNING VANES LONGER THAN 36 INCHES ARE REQUIRED, THEY SHALL BE

DOUBLE THICKNESS TYPE FOR STRENGTH.

15. FLEXIBLE DUCTWORK RUNOUTS AND BRANCH CONNECTIONS TO AIR DISTRIBUTION DEVICES

SHALL BE SAME DIAMETER AS AIR DISTRIBUTION DEVICE INLET CONNECTION UNLESS OTHERWISE

NOTED ON THE DRAWINGS.

16. FLEXIBLE DUCTWORK RUNOUTS FROM BRANCH DUCTS TO AIR DISTRIBUTION DEVICES SHALL NOT EXCEED 5 FEET IN LENGTH. BENDS IN FLEXIBLE DUCTWORK SHALL NOT EXCEED A MAXIMUM OF

45 DEGREE CHANGE OF DIRECTION AND BE SUPPORTED SUCH THAT THE BEND RADIUS IS NOT

RESTRICTIVE TO AIR FLOW THROUGH THE DUCT. FLEXIBLE DUCTWORK SHALL NOT BE CRUSHED

OR DISTORTED IN ITS FINAL CONFIGURATION.

17. ROUND DUCTWORK CONNECTIONS BETWEEN MAIN DUCT AND TERMINAL UNITS SHALL BE RIGID

DUCT OF THE SAME DIAMETER AS TERMINAL UNIT INLET CONNECTION UNLESS OTHERWISE

NOTED ON THE DRAWINGS.

18. PROVIDE SHEETMETAL TRANSITIONS AT AIR HANDLING UNITS, HEAT PUMP UNITS, FANS, AND

OTHER SIMILAR HVAC EQUIPMENT. FLEXIBLE DUCT CONNECTORS OR SOUND ATTENUATION

DEVICES SHALL BE USED ON CONNECTION TO AIR HANDLING EQUIPMENT TO REDUCE NOISE

TRANSFER INTO OCCUPIED SPACES.

19. OPEN-ENDED AIR TRANSFER DUCTS AND OPEN-ENDED RETURN AIR DUCTS IN THE CEILING

PLENUM SHALL BE UNOBSTRUCTED FOR A MINIMUM DISTANCE OF 24 INCHES FROM THE OPENING

TO ALLOW FOR FREE AIRFLOW. OPEN-ENDED AIR TRANSFER DUCTS AND OPEN-ENDED RETURN

AIR DUCTS IN THE CEILING PLENUM SHALL HAVE WIRE MESH SCREENS. MESH SCREENS SHALL BE

ALUMINUM WITH 1/8" SQUARE HOLES. SIZE FOR MAXIMUM VELOCITY OF 500 FPM.

20. TRANSFER DUCTS SHALL BE SIZED WITH SUFFICIENT BENDS TO REDUCE NOISE TRANSFER. MAX VELOCITY ALLOWED IS 500 FPM. OPEN-ENDED TRANSFER DUCTS SHALL HAVE DUCT "BOOT" FOR

SOUND ATTENUATION.

21. LOUVERED SUPPLY AIR DIFFUSERS SHALL BE 4-WAY BLOW UNLESS OTHERWISE SHOWN BY FLOW

ARROWS ON THE DRAWINGS. LINEAR DIFFUSERS SHALL BE ADJUSTABLE 2-WAY FLOW. PROVIDE

BATT INSULATION ON DIFFUSER AND GRILLES THAT ARE EXPOSED TO CEILING PLENUM.

22. DIMENSIONS SHOWN FOR DIFFUSERS AND GRILLES ARE NECK DIMENSIONS.

23. EXACT LOCATION OF CEILING DIFFUSERS, GRILLES AND REGISTERS SHALL BE DETERMINED BY

ARCHITECTURAL REFLECTED CEILING PLAN.

24. LOUVERS SHALL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR UNLESS

OTHERWISE NOTED ON THE DRAWINGS.

25. BLANK OFF AND INSULATE INACTIVE PORTIONS OF LOUVERS UTILIZED FOR INTAKE OR

DISCHARGE FOR HVAC EQUIPMENT. ENTIRE LOUVERS NOT UTILIZED SHALL BE BLANKED OFF AND

INSULATED BY THE LOUVER MANUFACTURER. REFER TO ARCHITECTURAL DRAWINGS FOR

LOUVER LOCATIONS AND HVAC DRAWINGS FOR HVAC EQUIPMENT CONNECTIONS.

26. LOUVER PLENUMS SHALL BE PITCHED BACK TOWARD THE BOTTOM OF THE LOUVER. WHERE THIS IS NOT POSSIBLE, PROVIDE DRAIN PIPING, WITH TRAP, FROM BOTTOM OF LOUVER TO NO MORE

THAN 6" ABOVE NEAREST SANITARY DRAIN.

27. PROVIDE ACCESS PANELS TO ACCESS DAMPERS, EQUIPMENT, AND VALVES LOCATED ABOVE

HARD CEILINGS OR IN WALLS. ACTUAL LOCATIONS SHALL BE FIELD DETERMINED.

28. EXACT LOCATIONS OF THERMOSTATS, CO2 SENSORS, AND EMCS SENSORS SHALL BE

COORDINATED WITH FINAL LOCATIONS OF WALL-MOUNTED ARCHITECTURAL AND ELECTRICAL

EQUIPMENT. MOUNT THERMOSTATS AND CO2 SENSORS MINIMUM 48" AFF.

29. AIR HANDLING UNITS SERVING OCCUPIED AREAS SHALL HAVE MINIMUM MERV 13 FILTERS. UNITS

NOT SERVING OCCUPIED ZONES SHALL HAVE MINIMUM MERV 8 FILTER TO PROTECT THE

EQUIPMENT MOTORS FROM DEBRIS AND CONTAMINANTS. FILTERS SHALL BE INDUSTRY

STANDARD SIZE, AND LOCATED AS ACCESSIBLE FOR MAINTENANCE. FILTERS SHALL NOT CREATE

PRESSURE DROP EXCEEDING 10% OF EXTERNAL STATIC PRESSURE (ESP) CAPACITY LISTED IN

EQUIPMENT SCHEDULE.

30. SUPPLY, RETURN, AND OUTDOOR AIR DUCTWORK SHALL BE INSULATED TO MEET OR EXCEED

ASHRAE 189.1-2014. INTERIOR SUPPLY, RETURN, AND OUTDOOR AIR DUCTWORK SHALL BE

INSULATED FOR A MINIMUM VALUE OF R-8. EXTERIOR SUPPLY AND RETURN AIR DUCTWORK SHALL

BE INSULATED FOR A MINIMUM VALUE OF R-8, AND PROVIDED WITH WEATHER-PROOF COVER.

31. SIZE REFRIGERANT LINES PER MANUFACTURER'S INSTRUCTIONS FOR ACTUAL LINE LENGTHS AND

EQUIPMENT ELEVATIONS INSTALLED. USE OF HCFC AND CFC REFRIGERANTS IS PROHIBITED.

EXTERIOR REFRIGERANT LINES SHALL BE INSULATED. PROTECT EXTERIOR REFRIGERANT LINES

WITH ALUMINUM JACKETING.

32. PIPING CONTAINING WATER SHALL BE INSULATED AND HEAT-TRACED WHERE EXPOSED TO

FREEZING TEMPERATURES.

33. COORDINATE LOCATIONS OF CONDENSATE DRAIN PIPING. PROVIDE CONDENSATE PUMPS AS

REQUIRED WHERE SUFFICIENT SLOPE IS NOT AVAILABLE FOR STANDARD GRAVITY DRAIN, WITH

OVERRIDE SWITCH TO POWER DOWN THE ASSOCIATED AIR HANDLING EQUIPMENT IN CASE OF

CONDENSATE PUMP FAILURE. CONDENSATE DRAIN PIPING SHALL BE SLOPED FOR GRAVITY AT A MINIMUM OF 1/8" PER FOOT. INSULATE INDOOR CONDENSATE PIPING WITH 3/4" INSULATION.

34. PROVIDE SUPPORTS FOR PIPING AND DUCTWORK IN ACCORDANCE WITH SPECIFICATIONS.

35. PROVIDE EXPANSION LOOPS OR APPROVED FLEXIBLE PIPE EXPANSION DEVICES FOR PIPING

SYSTEMS WITH OPERATING TEMPERATURES ABOVE 70°F OR BELOW 50°F. PIPE SUPPORTS FOR

PIPING SYSTEMS WITH EXPANSION DEVICES OR EXPANSION LOOPS SHALL HAVE ROLLER

SUPPORTS.

36. PROVIDE AUTOMATIC AIR VENTS AT HIGH POINTS OF THE CHILLED WATER AND HOT WATER PIPING SYSTEMS. PROVIDE DRAIN VALVES AT THE LOW POINTS IN THE SYSTEMS FOR DRAINAGE.

37. COORDINATE WITH STRUCTURAL. PROVIDE HOUSEKEEPING PADS FOR MECHANICAL EQUIPMENT.

38. PROVIDE SHUT-OFF VALVES AT PIPE CONNECTIONS TO EQUIPMENT AND FLEXIBLE CONNECTIONS.

39. FOR WALL, FLOOR, AND SLAB PENETRATIONS SEAL AND PATCH ALL UNUSED PENETRATION

SPACE TO MATCH EXISTING OR AS SHOWN ON MECHANICAL DETAILS SHEET.

40. INSTALL EXPOSED CONTROL WIRING IN CONDUIT. SEE DIVISION 26 SPECIFICATIONS FOR

REQUIREMENTS.

41. BRANCH VALVES AND DRAINS SHALL BE PROVIDED TO ENABLE ISOLATING A SECTION FOR

MAINTENANCE WITHOUT SHUTTING DOWN ENTIRE SYSTEM.

42. MANUFACTURER NAME AND MODEL NUMBERS ARE BASIS OF DESIGN AND ARE SHOWN FOR

INFORMATION ONLY. PLEASE REFER TO SPECIFICATION SECTION 23 00 00 - AIR SUPPLY,

DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS, SUBSECTION 2.2 - STANDARD PRODUCTS, FOR COMPLETE REQUIREMENTS AND VERBIAGE THAT MANUFACTURERS THAT COMPLY WITH THE

SPECIFICATION ARE ALLOWABLE FOR SUBMITTAL AND GOVERNMENT APPROVAL.

43. DUCTWORK INSULATION SHALL BE PROVIDED ON ALL SYSTEMS INCLUDING BUT NOT LIMITED TO

SUPPLY, RETURN, OUTSIDE AIR, AND EXHAUST AIR IN ACCORDANCE WITH ASHRAE 90.1.

44. PIPING INSULATION SHALL BE PROVIDED ON ALL SYSTEMS INCLUDING BUT NOT LIMITED TO

CHILLED WATER, HEATING HOT WATER, REFRIGERANT, AND CONDENSATE IN ACCORDANCE WITH

ASHRAE 90.1.

45. DUCTWORK INSULATION SHALL MATCH EXISTING IN AREAS WHERE NEW DUCTWORK IS

PROVIDED.

46. ALL EQUIPMENT WITH NATURAL GAS COMBUSTION ARE TO BE VENTED PER THE APPLICABLE

CODES.

47. SPECIFICATIONS TAKE PRECEDENCE OVER DRAWINGS. HOWEVER, ITEMS SHOWN ON DRAWING

BUT NOT IN THE SPECIFICATIONS ARE REQUIRED WITHIN THE PROJECT SCOPE.

48. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S APPROVED

PUBLISHED LITERATURE.

49. DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS.

50. EXPOSED DUCTWORK, WITH THE EXCEPTION OF DUCTWORK IN MECHANICAL ROOMS SHALL BE

DOUBLE-WALL, SPIRAL DUCTWORK WITH COATING.

51. IF ASBESTOS IS FOUND, STOP WORK IMMEDIATELY AND NOTIFY OWNER AND GENERAL

CONTRACTOR. OWNER IS RESPONSIBLE FOR ABATEMENT OF ASBESTOS.

52. NOT ALL MECHANICAL ABBREVIATIONS SHOWN WILL BE USED FOR THIS PROJECT.

GENERAL MECH. ABBREVIATIONS

@ AT

& AND

AFF ABOVE FINISHED FLOOR

A/C ABOVE CEILING

AC AIR CONDITIONER

AD AUTOMATIC DAMPER

ADJ ADJUSTABLE

AFMS AIRFLOW MEASURING STATION

AFUE ANNUAL FUEL UTILIZATION EFFICIENCY

AHU AIR HANDLING UNIT

APPROX., ± APPROXIMATELY

AMCA AIR MOVEMENT AND CONTROL ASSOCIATION

ARCH ARCHITECT, ARCHITECTURAL

AS AIR SEPARATOR

ASHRAE AMERICAN SOCIETY OF HEATING,

REFRIGERATING, AND AIR CONDITIONING

ENGINEERS

ASTM AMERICAN SOCIETY FOR TESTING AND

MATERIALS

AUX AUXILIARY

AWS AMERICAN WELDING SOCIETY

AWG AMERICAN WIRE GAUGE

B BOILER

BD BACKDRAFT DAMPER

BLDG BUILDING

BOD BOTTOM OF DUCT

B/F BELOW FLOOR

B/S BELOW SLAB

BT BUFFER TANK

BTU, BTUH BRITISH THERMAL UNITS, BTUs PER HOUR

CA COMBUSTION AIR INTAKE

CAV CONSTANT AIR VOLUME

CD CONDENSATE DRAIN

CFM CUBIC FEET PER MINUTE

CLG COOLING

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

CO2 CARBON DIOXIDE

CONC CONCRETE

CONN CONNECT, CONNECTING, CONNECTION

CONT CONTINUED

COP COEFFICIENT OF PERFORMANCE

COR CONTRACTING OFFICER'S (OWNER'S)

REPRESENTATIVE

CU CONDENSING UNIT

CH CHILLER

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CRAC COMPUTER ROOM AIR CONDITIONER

CRCU COMPUTER ROOM CONDENSING UNIT

CWR CONDENSER WATER RETURN

CWS CONDENSER WATER SUPPLY

D DEPTH

DB, Tdb DRY BULB (TEMPERATURE) dBA DECIBELS

DDC DIRECT DIGITAL CONTROLS

DEG. F (°F) DEGREES FAHRENHEIT

DF DESTRATIFICATION FAN

DH DEHUMIDIFIER

DIA DIAMETER

DIV DIVISION

DN DOWN

DP, PD DIFFERENTIAL PRESSURE, PRESSURE DROP

DSCU DUCTLESS SPLIT CONDENSING UNIT

DSFC DUCTLESS SPLIT FAN COIL UNIT

DSHP DUCTLESS SPLIT HEAT PUMP

DSS DUCTLESS SPLIT SYSTEM (INDOOR UNIT)

DWG DRAWING

DX DIRECT EXPANSION

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EER ENERGY EFFICIENCY RATIO

EF EXHAUST FAN

EFF EFFICIENCY

ELEC ELECTRICAL

ERV ENERGY RECOVERY VENTILATOR

ET EXPANSION TANK

ESP EXTERNAL STATIC PRESSURE

EUH ELECTRIC UNIT HEATER

EWT ENTERING WATER TEMPERATURE

EXT EXTERIOR

EXH EXHAUST

EXST EXISTING

FCU FAN COIL UNIT

FD FIRE DAMPER

FFE FINISHED FLOOR ELEVATION

FLA FULL LOAD AMPS

FOB FLAT ON BOTTOM

FOT FLAT ON TOP

FSD FIRE SMOKE DAMPER

FT FOOT, FEET

FT WG FEET WATER GAUGE

FV FLUE VENT

GA GAGE

GC GENERAL CONTRACTOR

GPM GALLONS PER MINUTE

H HEIGHT

HGRH HOT GAS REHEAT

HP HEAT PUMP

HR HOUR

HSPF HEATING SEASONAL PERFORMANCE FACTOR

HTG HEATING

HTR HEATER

HUH HYDRONIC UNIT HEATER

HVAC HEATING, VENTILATING, AND AIR

CONDITIONING

HX HEAT EXCHANGER

HZ HERTZ

IMC INTERNATIONAL MECHANICAL CODE

IN INCH, INCHES

IN WC INCHES WATER COLUMN

IN WG INCHES WATER GAUGE

IPLV INTEGRATED PART LOAD VALUE

KW KILOWATTS

L LENGTH, LOUVER (WALL)

LAT LEAVING AIR TEMPERATURE

LBS POUNDS

LWT LEAVING WATER TEMPERATURE

MAX MAXIMUM

MBH 1000 BRITISH THERMAL UNITS

MCA MINIMUM CIRCUIT AMPACITY

MERV MINIMUM EFFICIENCY REPORTING VALUE

MECH MECHANICAL

MFR, MFG MANUFACTURER, MANUFACTURING

MIN MINIMUM

MOCP, MOP MAXIMUM OVER CURRENT PROTECTION

MOD MOTOR OPERATED DAMPER

MSS MANUFACTURER'S STANDARDIZATION SOCIETY

MTD MOUNTED

MUW MAKE-UP WATER (POTABLE/ DOMESTIC)

MVD MANUAL VOLUME DAMPER

N.C. NORMALLY CLOSED

NO. NUMBER

N.O. NORMALLY OPEN

NPLV NET PART LOAD VALUE

NTS NOT TO SCALE

OA OUTSIDE AIR

OD OUTSIDE DAMPER

PD PRESSURE DROP

PH PHASE

PLBG PLUMBING

PPM PARTS PER MILLION

PRV PRESSURE RELIEF VALVE

PSI POUNDS FORCE PER SQUARE INCH

QTY QUANTITY

RA RETURN AIR

RG RETURN GRILLE

RH RELATIVE HUMIDITY, ROOF HOOD

RHG REFRIGERANT HOT GAS

RL REFRIGERANT LIQUID

RLA RELIEF AIR

RM ROOM

RPM REVOLUTIONS PER MINUTE

RS REFRIGERANT SUCTION

SA SUPPLY AIR

SD SMOKE DAMPER, SMOKE DETECTOR

SEER SEASONAL ENERGY EFFICIENCY RATIO

SF SUPPLY FAN

SMACNA SHEET METAL AND AIR CONDITIONING

CONTRACTOR'S NATIONAL ASSOCIATION

SP STATIC PRESSURE

SS STAINLESS STEEL

TSTAT THERMOSTAT

TEMP TEMPERATURE

TG TRANSFER GRILLE

THA TOTAL HEAT ABSORPTION

THR TOTAL HEAT REJECTION

TP TEMPERATURE/ PRESSURE TEST PORT

TYP TYPICAL

UH UNIT HEATER

UL UNDERWRITER'S LABORATORY

UMCS UTILITY MONITORING AND CONTROL SYSTEM

V VOLTAGE, VOLTS

VAV VARIABLE AIR VOLUME

VD VOLUME DAMPER

VFD VARIABLE FREQUENCY DRIVE

VSD VARIABLE SPEED DRIVE

W WATT(S)

W/ WITH

W/O WITHOUT

WB, Twb WET BULB (TEMPERATURE)

WD WIDE, WIDTH

WMS WIRE MESH SCREEN

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

P

O B o x

S yr a c u s e

N Y

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:0

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

M-001

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L G

E N

E R

A L N

O T

E S

A N

D A

B B

R E

V

IA

T

IO

N S

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

AIR DISTRIBUTION DEVICE TAGS

DIFFUSER TYPE

A

400 AIRFLOW

DIFFUSER TYPE

A 24x24 FACE SIZE

SUPPLY/RETURN/EXHAUST TAGS

TRANSFER GRILLE TAGS

M501

PLAN NORTH

TRUE

NORTH

DRAWING/DETAIL REFERENCE KEY

REFER TO

DETAIL NUMBER

SHEET NUMBER OF DETAIL

RE:2/M501

NORTH ARROW

A

J

SD

SP

F

A

C

DUCT SMOKE DETECTOR

CARBON DIOXIDE SENSOR

DRAWING NOTE REFERENCE

OVAL OR FLAT OVAL

CONTROL WIRING

STATIC PRESSURE SENSOR

ROUND

FIRESTAT

TEMPERATURE SENSOR

MISCELLANEOUS LEGEND

T

120 VOLT STAND BY POWER JUNCTION

BOX PROVIDED BY THE ELECTRICAL

CONTRACTOR JUNCTION BOX IS

DEDICATED FOR USE BY THE CONTROLS

CONTRACTOR.

VARIABLE FREQUENCY DRIVEVFD

PIPING LEGEND

EXPANSION JOINT

FLEXIBLE CONNECTION

CLEANOUT

WATER METER

FLOOR CLEANOUT

THERMOMETER

PRESSURE REDUCING VALVE

MANUAL AIR VENT

WITH BALL VALVE

PRESSURE/TEMPERATURE TAP

PRESSURE SWITCH

PLUG VALVE

FLOW SWITCH

T&P RELIEF VALVE

AUTOMATIC AIR VENT

PRESSURE GAUGE WITH GAUGE COCK

PS

FS

BUTTERFLY VALVE

STRAINER WITH BLOWDOWN VALVE,

FLOW MEASURING/BALANCING/

SHUT-OFF VALVE

GATE VALVE

CHECK VALVE

BALL VALVE

CAP, AND CHAIN

CONCENTRIC REDUCER

DIRECTION OF FLOW

DIRECTION OF SLOPE DOWN

ECCENTRIC REDUCER

PIPE FLANGE

PIPE CAP

PIPE GUIDE

PIPE ANCHORX

UNION

TEE OUTLET UP

CONDENSATE DRAIN

BRANCH BOTTOM CONNECTION

BRANCH TOP CONNECTION

ELBOW UP

ELBOW DOWN

RISE OR DROP

TEE OUTLET DOWN

PUMPED DISCHARGE

M

SUPPLY OR OUTSIDE AIR DUCT UP

AD

FD(3) - FIRE DAMPER, 3 HOUR RATING

FD - FIRE DAMPER, 1 HOUR RATING

FIRE DAMPER TYPE:

H

UP

DN

DUCT MOUNTED HUMIDIFIER

RISE IN DUCT

DROP IN DUCT

RETURN OR EXHAUST AIR DUCT DOWN

RETURN OR EXHAUST AIR DUCT UP

SUPPLY OR OUTSIDE AIR DUCT DOWN

30"x14"

SQUARE TO ROUND DUCT BRANCH TAKE-OFF

FLARED SPIN-IN WITH DAMPER AND

FLEX DUCT (DIFFUSER CONNECTION)

ROUND DUCT BRANCH TAKE-OFF FROM

RECTANGULAR MAIN WITH CONICAL TAP

FLEXIBLE DUCT CONNECTION

WITH 45 DEGREE BRANCH INLET

FLOW ARROW

DUCT SIZE TRANSITION

RECTANGULAR DUCT BRANCH TAKE-OFF

WITH 45 DEGREE BRANCH INLET

DASHED LINES INDICATE 2" ACOUSTICAL LINER

90 DEGREE DUCT ELBOW WITH TURNING VANES

FLEXIBLE DUCT

24"Ø

DUCTWORK LEGEND

RETURN AIR DEVICE

ROUND DUCT. DIAMETER INDICATED IN INCHES.

IN-LINE 90 DEGREE RISE/DROP IN

SUPPLY DUCT (RIGHT SIDE IS HIGHER)

IN-LINE 90 DEGREE RISE/DROP IN

RETURN DUCT (RIGHT SIDE IS HIGHER)

FD

SD

AD - AUTOMATIC DAMPER

DAMPER TYPE:

MD - MOTORIZED DAMPER

VD

SMOKE DAMPER

VOLUME/BALANCING DAMPER

(LABEL MAY BE OMITTED)

BD

BACKDRAFT DAMPER

(COUNTER-BALANCED UNLESS

OTHERWISE NOTED)

RADIUS DUCT ELBOW - ROUND OR

RECTANGULAR (MIN. 1.5 RADIUS UNLESS

OTHERWISE NOTED)

RECTANGULAR DUCT, SIZE INDICATED IN

INCHES, FIRST NUMBER IS SIDE SHOWN

SUPPLY AIR DIFFUSER -

FLOW ARROWS INDICATE AIR PATTERN.

NO FLOW ARROWS SHOWN INDICATES

4-WAY PATTERN.

FSD

COMBINATION

FIRE/SMOKE DAMPER

EXHAUST / RELIEF AIR DEVICE

SERVICE CLEARANCE

T THERMOSTAT

H HUMIDISTAT

$ START/ STOP SWITCH

TH THERMOSTAT/ HUMIDISTAT

HUMIDITY SENSORH

REFRIGERANT HOT GAS

REFRIGERANT LIQUIDRL

HEATING HOT WATER RETURNHWR

HEATING HOT WATER SUPPLYHWS

REFRIGERANT SUCTIONRS

PD

RHG

CD

CHILLED WATER RETURNCHWR

CHILLED WATER SUPPLYCHWS

CONDENSER WATER RETURNCWR

CONDENSER WATER SUPPLYCWS

DESIGN CONDITION SCHEDULE

UNOCC.

DRY BULB

OCC.

DRY BULB

OCC.

DEWPOINT

UNOCC.

DRY BULB

OCC.

DRY BULB

COOLING COOLINGHEATING HEATING

DRY

BULB

WET

BULB

DRY

BULB

INDOOR (°F) OUTDOOR (°F)

SPACE CATEGORY

ADMINISTRATION SPACES 6855

VESTIBULES

MECH/ELEC ROOMS

STORAGE

COMMUNICATION ROOMS

RESTROOMS

7885 55 85.2 6.9

4040---- --

68557885 55

55409595 78.9

68557885 55

55557575 55

43.11 N

LONGITUDE:

ELEVATION:

LATITUDE:

SUMMER DESIGN WET BULB (1.0%):

SUMMER DESIGN DRY BULB (1.0%):

WINTER DESIGN DRY BULB (99.0%):

STANDARD DESIGN CONDITIONS:

85.2°F

78.94 W

585 FT.

HVAC DESIGN CRITERIA

*STANDARD & CRITICAL DESIGN CONDITIONS FROM UFC 3-400-02.

MEAN COINCIDENT DRY BULB (1.0%):

HUMIDITY RATIO (1.0%):

DEHUMIDIFICATION DESIGN CONDITIONS:

DEWPOINT (1.0%):6.9°F

71.0°F

117.5

71.2°F

78.3°F

PROJECT LOCATION:

NIAGARA FALLS INTL, NY

SHEET NAMING CONVENTION

M-001A

2 DIGIT SEQUENTIAL #

(01-99) (FIRST DIGIT

INDICATES PLAN TYPE.

SECOND DIGIT INDICATES

FLOOR)

1 DIGIT SHEET TYPE DESIGNATOR

0 - GENERAL

1 - PLANS

2 - ELEVATIONS

3 - SECTIONS

4 - ENLARGED PLANS

5 - DETAILS

6 - SCHEDULES AND DIAGRAMS

7 - VARIES

8 - VARIES

9 - 3D VIEWS (ISO, PERSPECTIVES)

2 DIGIT DESCIPLINE

DESIGNATOR

(IF ONLY ONE LETTER IS

USED, THE SECOND LETTER

IS REPLACED WITH A DASH

"-" AS A PLACEHOLDER)**

1 DIGIT AREA

DESIGNATOR

(AREA DESIGNATOR

ONLY USED WHEN

PLANS ARE

SUBDIVIDED INTO

AREAS.)

30"/14"

85.2

85.2

85.2

85.2

85.2

71.0

71.0

71.0

71.0

71.0

71.0

6.9

6.9

6.9

6.9

6.9

EQUIPMENT PAD

CONNECT TO EXISTING

DISCONNECT FROM EXISTING

LINEAR SLOT DIFFUSER

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:1

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

M-002

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L L

E G

E N

D S

A N

D H

V A

C D

E S

IG

N

C R

IT

E

R

IA

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

1 2 4 6 7 8 9 16

12' 13'10' 15'

A

C

6a

9' 16'

20"x12"

16"x8" 20"x10"

14"x10"

18"x10"

12"x12"

"x

12"x10"

12"x10"

8"x4"

16"x4"

12"x12"

12"x6"

14"x12"

18"x10"

12"x14"

18"x8"

12"x6"

12"x6" 14"x8"

8"x6"

16"x8"

12"x8"

12"x6"

16"x8"

10"x8"

10"x6"

14"x14"

12"x4"

14"x10"

12"x10"

12"x8"

"x

"x

"x

10"x6"

14"x8"

16"x8"

10"x6"

6"x6"

10"x8"

16"x10"

12"x12"

12"x10"

"x

10"x6"

16"x14"

12"x6"

20"x6"

12"x10" 12"x8"

12"x8"

8"x4"

6"x4"

18"x8"

18"x8"

12"x12"

12"x8"

12"x8"

12"x10" 12"x8"

20"x10" 20"x10"

16"x6"

16"x8" 14"x8"

12"x12"

8"x4"

24"x8"

"x

12"x12"

12"x6"

14"x8" 24"x8"

30"x8"

14"x8" 14"x12"

14"x8"

24"x12"

10"x10"

"x

26"x8"

14"x8"

16"x8"

20"x10"

30"x12"

16"x8"

20"x10"

"x

16"x8"

8"x6"

14"x10"

10"x6"

12"x10" 10"x10"

"x

12"x4" 10"x6"

25"x14"

6"x6"

6"x4"

10"x6"

10"x6"

14"x8"

18"x10"

10"x6"

24"x8"

25"x14"22"x8"

14"x8"

24"x14"

12"Ø 14"x12"

24"x8"

25"x14"

14"Ø

14"Ø

18"x10"

8"Ø

12"x8"

10"x8"

8"x6"

16"x14"

16"x12"

16"x10"

14"x8"

14"x8"

16"x10" 6"x6"

14"x8"

24"x12"

20"x10" 6"Ø 6"Ø26"x8"

6"Ø 6"Ø

14"x8"

14"x8"

14"x6"

14"x10"

14"x6"

12"x8"

8"Ø

8"Ø

10"Ø

24"x12"

20"x10" 6"Ø 6"Ø

6"Ø6"Ø

18"x10"

12"x8"

16"x8"

12"x8"

12"x8"

16"x8"

16"x10"

8"x10"

14"x12"

12"x10" 12"x8"

8"x8"

18"x6" 14"x4"

16"x8"

14"x10"

12"x6"

14"x8"

12"x6"

6"x4"

8"x8"

12"x8"

18"x10"

12"x6"

"x

"x

"x

16"x10"

12"x6"

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

EF

M A

TC

H

L

IN

E

S E

E A

1/ M

D

KEYNOTES:

KEY PLAN

SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 8 168

1/8"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:3

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MD101

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L D

E M

O L

IT

IO

N

P L A

N

F

IR

S T

F L O

O R

A R

E A

A

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND

ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND HVAC

DESIGN CRITERIA.

SCALE: 1/8" = 1'-0"A1

MECHANICAL DEMOLITION PLAN - FIRST FLOOR AREA A

1 DEMOLISH ALL AIR DEVICES.

DEMOLISH ALL WATER SOURCE HEAT PUMPS AND

ASSOCIATED APPURTENANCES.

DEMOLISH CONDENSER WATER SUPPLY AND

RETURN PIPING.

KEYNOTES:

16 17 18 19 21 23

2420 22

A

B

D

C

E

F

G

H

19a

8"Ø

10"Ø

10"Ø

16"x10"

12"x10"

20"x14"

"x

"x

"x

8"Ø 10"Ø

8"Ø

"x

"x

12"x6" 10"Ø 12"x8"

"x

12"x8"

16"x6"

"x

6"Ø

6"Ø

6"Ø

"x

12"x10"

12"x10"

12"x8"

14"x8" 16"x8" 20"x8" 30"x10" 26"x8"

30"x10"

"x

"x

8"Ø

10"Ø

18"x10"

8"Ø8"Ø

"x

"Ø

"x

6"Ø 18"x10"

16"x12"

10"x8" 10"x8"

10"x6"

"x

25"x14"

18"x10"

14"x8"

14"x8"

10"x10"

6"Ø

10"x8"

12"x6"

"x

18"x10" 14"x8"14"x8"

24"x10" 16"x10"16"x10"

12"x12"

12"x6"

26"x14"

20"x10"

16"x10" 16"x10"

24"x10"

12"x6"

10"x8"

20"x8"

24"x10"

6"Ø

25"x14"

22"x12"

12"x8"

18"x12"

16"x10"

12"x8"

14"x10"

14"x14"

16"x12"

12"Ø

8"Ø

6"x6"

6"x6"

12"x8"

12"x10"

12"Ø

12"x8"

10"x6"

12"x12"

14"x8"

"x

12"x8"

16"x8"

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

M A

TC

H

L

IN

E

S E

E A

1/ M

D

B4

MD102

A

B

KEY PLAN

SCALE: = 1'-0"SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 8 168

1/8"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

3/32"

0 8 16 248

/1

/2

:4

:4

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MD102

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L D

E M

O L

IT

IO

N

P L A

N

F

IR

S T

F L O

O R

A R

E A

B

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND

ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND HVAC

DESIGN CRITERIA.

SCALE: 1/8" = 1'-0"A1

MECHANICAL DEMOLITION PLAN - FIRST FLOOR AREA B

SCALE: 1/8" = 1'-0"B4

MECHANICAL DEMOLITION PLAN - STEAM ROOM

1 DEMOLISH ALL AIR DEVICES.

DEMOLISH ALL WATER SOURCE HEAT PUMPS AND

ASSOCIATED APPURTENANCES.

DEMOLISH 150 TON CLOSED CIRCUIT COOLER AND

APPURTENANCES INCLUDING (BUT NOT LIMITED TO)

EXISTING CONCRETE PAD.

DEMOLISH CONDENSER WATER SUPPLY AND RETURN

PIPING.

5 DEMOLISH (3) BASE-MOUNTED PUMPS.

DEMOLISH (3) GAS-FIRED HOT WATER BOILERS AND

BOILER PUMPS. PATCH AND SEAL FLUE AND

COMBUSTION OPENINGS.

4 6 7 8 9 16

12' 13'10' 15'

A

B

D

C

E

L'

K'

J'

H'

G'

F'

6a

F

G

H

9' 16'

E'

30"x12"

16"x8"

16"x12"

16"x8"16"x8"

16"x12"

16"x8"

16"x8"

16"x8"

16"x8"

30"x12"

30"x12"

"x

16"x8" 16"x12"

"x

16"x8" 12"x8"12"x8" 12"x8"12"x8"1 "x

30"x12"

24"x10"

48"x18"

34"x8"

36"x12"

25"x10"

26"x8"

14"x12"

10"x6"

10"x6"

14"x8"

"x

"x

" 12"x6"12"x6"

16"x12"

12"x6"

12"x6"

14"x10"14"x10"

"x

"x

14"x10"14"x10" 12"x6"12"x6"

26"x8"26"x8"

30"x12"

"x

24"x12"

14"x8"14"x8" 14"x8"14"x8"

20"x8"

20"x8"

10"x10"

26"x8"

24"x8"

"x

"x

20"x8"

30"x10"

20"x8"

18"x8"

14"x8"14"x8" 14"x8"14"x8"

"x

"x

18"x10"

14"x8"

20"x10"

24"x10"

"x

6"x6"

"x

12"x8"

10"x6"

"x

12"x6"12"x6"

"x

"x

10"Ø10"Ø 10"Ø10"Ø 1

"x

20"x10" 10"x6"

20"x10"

10"Ø

10"Ø

"x

12"x10" 10"Ø10"Ø

16"x18"

14"x18"

25"x14"16"x8"

"x

14"x8"

22"x8"

22"x8" 8"x6"

8"x4"

36"x20"

18"x14"

16"x12"

14"x10" 14"x10"

16"x12"

18"x14"

10"x8"

8"x6"

18"x14"

90"x36"

"x

32"x14"

"x

"x

"x

36"x20"

16"x12"

14"x10"

14"x10"

16"x12"

18"x14"

38"x10" 36"x20"

8"x6"

18"x14"

16"x12"

14"x10" 14"x10"

16"x12"

18"x14"

8"x6" 10"x8"

36"x20"

38"x10"38"x10"

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

M A

TC

H

L

IN

E

S E

E A

1/ M

D

KEYNOTES:

KEY PLAN

SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 8 168

1/8"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:5

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MD103

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L D

E M

O L

IT

IO

N

P L A

N

S E

C O

N D

F L O

O R

A R

E A

A

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

SCALE: 1/8" = 1'-0"A1

MECHANICAL DEMOLITION PLAN - SECOND FLOOR AREA A

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND

ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND HVAC

DESIGN CRITERIA.

1 DEMOLISH ALL AIR DEVICES.

DEMOLISH ALL WATER SOURCE HEAT PUMPS AND

ASSOCIATED APPURTENANCES.

DEMOLISH CONDENSER WATER SUPPLY AND RETURN

PIPING.

2420 22

A

B

D

C

E

F

G

H

19a

"x

10"Ø10"Ø 8"Ø8"Ø

8"Ø

8"Ø

14"x10"

8"Ø

8"Ø

10"x8"

26"x8"

12"Ø12"Ø

"x

18"x10"

10"Ø10"Ø 10"Ø10"Ø

"x

20"x12" 12"x8"

10"Ø

26"x12"

16"x18"

18"x10"

"x

8"Ø8"Ø

10"Ø

10"Ø 10"Ø

10"Ø

20"x12"

18"x10"

"x

12"x10"

8"Ø8"Ø 8"Ø8"Ø

"x

48"x48"

"x

20"x10"

18"x10"

8"Ø

8"Ø

14"Ø

"x

16"x8"

"x

"Ø

"Ø

"Ø12"x10"

16"x12"

32"x10"

20"x12" 12"x8"

18"x18"

18"x18" 10"x10"

22"x12"

"x

22"x12"

10"x10" "x

8"Ø

12"x10"

14"x10"

6"x4"

"x

"x

"x

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

M A

TC

H

L

IN

E

S E

E A

1/ M

D

KEYNOTES:

KEY PLAN

SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 8 168

1/8"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:0

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MD104

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L D

E M

O L

IT

IO

N

P L A

N

S E

C O

N D

F L O

O R

A R

E A

B

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

SCALE: 1/8" = 1'-0"A1

MECHANICAL DEMOLITION PLAN - SECOND FLOOR AREA B

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND

ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND HVAC

DESIGN CRITERIA.

1 DEMOLISH ALL AIR DEVICES.

DEMOLISH ALL WATER SOURCE HEAT PUMPS AND

ASSOCIATED APPURTENANCES.

DEMOLISH CONDENSER WATER SUPPLY AND RETURN

PIPING.

4 6 7 8 9 16

12' 13'10' 15'

A

B

D

C

E

L'

K'

J'

H'

G'

F'

6a

F

G

H

9' 16'

E'

VAV-1-101

VAV-1-102

VAV-1-103

VAV-1-104

VAV-1-108

VAV-1-105

VAV-1-106

VAV-1-107

VAV-2-104

VAV-2-103

VAV-2-101

VAV-2-102

VAV-3-109

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

C

C

C

C

C

C

C

C

C

C

C

95 C

C

C

C

C

A

SF/ COMM

CORRIDOR

CHIEF OF SECURITY

MEN

MECHANICAL

WEST STAIR

C

10"x8"

6"x6"

8"x8"

6"x6"

6"x6"

"x

D

"x

D

10"x8"

12"x12"

16"x16"

18"x16"

"x

D

6"x6"

6"x6"

6"x6"

8"x6"

"x

10"x10"

"x

12"x12"

D

"x

6"x6"

8"x8"

8"x8"

D

D

12"x12"

12"x12"

WEAPONS

MAINTENANCE

PPE TRAINING BAG

STORAGE

FLIGHT CHIEFS

C

6"x6"

D

1755 18"x14"

16"x14"

"x

8"Ø

8"Ø

8"Ø

6"x6"

10"x8"

"x

"x

"x

12"x12"

14"x12"

"x

6"Ø

"x

8"Ø

8"Ø

"Ø

"Ø

8"x8"

10"x10"

"x

10"x8"

8"Ø

6"Ø "Ø

8"Ø 8"Ø

"x

8"x8"8"Ø

"Ø

6"Ø

6"Ø6"Ø6"Ø

10"x8" 8"x8" 8"x6"

12"x10"10"x8"

"Ø

"x

"Ø

"Ø 8 "Ø

8"Ø

"Ø

6"Ø

16"x14"

"x

"x

12"x12"

"x

"Ø

8"Ø

8"Ø

8"Ø

8"Ø

8"Ø

"x

12"x10"

8"x8"

"x

6"Ø

6"Ø

6"Ø 6"Ø

6"Ø

6"Ø

8"Ø

8"Ø

6"Ø

10"Ø

14"x12"

8"Ø

"Ø

6"Ø

"x

VAULT

016A

DATA CENTER

SHARED WAITING

ROOM

E

E

32"/22"

HP-1

DSCU-2

"x

34"/12"

24"x10"

24"x10"

32"/24" 22"/12"

CRAC-1 CRAC-2

CRCU-1 CRCU-2

DSS-2

B

B

"x

F

F

F

D

D

F

F

F

F

F

10"x8"

"x

"Ø

"Ø

24"x16" 44"x16"

"x

"Ø

8"Ø

8"Ø

8"Ø

8"Ø

8"Ø8"Ø

"x

A

A

A

A

"x

DSCU-3

DSCU-1

DSS-1

"x

50"x16"

34"x22"

34"x22"

M-402 A1

M-401 A1

8"Ø

8"Ø

12"Ø 12"Ø

B

E

"x

12"x12"

WEAPONS

CLEARING

EQUIPMENT

LOCKERS

CATM ADMIN

021CATM NCOIC

021A

HOTEL W/S

SF/ CATM

CORRIDOR

TRAINING ROOM

019PPE TRAINING BAG

STORAGE

RECORDS STAGING/

STORAGE

SECURE STORAGE

(CRYPTO)

COMMANDER

PLANS &

RESOURCES CHIEF

STAN/EVAL

ITE

STAGING/STORAGE

UTC PREVENTIVE

MAINTENANCE

COMM OPEN OFFICE

SF XO/NCO

SF COMMANDER

SF FIRST

SERGEANT

LAW

ENFORCEMENT

DESK

INFORMATION

PROTECTION CHIEF

PROGRAM

MANAGEMENT

COMM OPEN OFFICE

B

B

38"x24"

38"x24"

G

(TYP.

OF 8)

OPERATIONS CHIEF

SECOND OFFICER

CEM

COMM C/S

"x

"x

BUDGET OFFICE

W/C 1

W/C 2

FSS C/S

E

E

6"x6" 6"x8"

"x

6"x6" 6"x6"

A

A

A

A

14"x14"

12"Ø

"Ø 1 "Ø

12"Ø

"x

20"x16" 12"Ø

8"x8"

"x

F

10"x10"

B

B

8"x6" B

6"x6"

B

B

10"x6"

10"x6"

6"x6"

"x

12"x10"

12"x10"

B

B

6"x6"6"x6"

B

B

D

10"x8"

14"x6" B

"x

10"x8"

C

SF OPEN OFFICE

E

12"x12"

12"x14"

D

24"x12"

EUH-4

EUH-2

EF-9

MD

912"x12"

C

F

14"x8"

14"x8"

10"x10"

8"x8"

8"x6" 8"x6"

6"x6"

M A

TC

H

L

IN

E

S E

E A

1/ M

H

ELEV MACHINE RM

LOWER LANDING

10"Ø

12"Ø

"Ø

"Ø

14"Ø

14"x14"

"Ø

"Ø

8"x8"

"Ø

"Ø

101010

34"x24"

E

12"x12"

L-7

24"x16"

10"/6"

10"/6"

8"Ø

8"Ø

10"/6"

8"Ø

16"/8"

VEST

101A

6"x6"

ELEV MACHINE RM

DOOR ACCESS

24"x12" RLA UP

EF-8

L-12

KEYNOTES:

KEY PLAN

SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 8 168

1/8"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:1

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MH101

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L H

V A

C P

L A

N

F

IR

S T

F L O

O R

A R

E A

A

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

SCALE: 1/8" = 1'-0"A1

HVAC PLAN - FIRST FLOOR AREA A

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND

ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND HVAC

DESIGN CRITERIA.

20"x20" RETURN DUCT DOWN FROM SECOND

FLOOR. SEE A1/MH103 FOR CONTINUATION. FIRE

DAMPERS ARE TO BE LOCATED IN THE VERTICAL

DUCT AT FLOOR TO FLOOR PENETRATION.

30"/20" SUPPLY DUCT UP TO SECOND FLOOR.

SEE A1/MH103 FOR CONTINUATION. FIRE

DAMPERS ARE TO BE LOCATED IN THE VERTICAL

DUCT AT FLOOR TO FLOOR PENETRATION.

RETURN OPEN UNDER RAISED FLOOR. COVER

OPENING WITH WIRE MESH.

10"x16" EXHAUST DUCT UP TO SECOND FLOOR.

SEE A1/MH103 FOR CONTINUATION. FIRE

DAMPERS ARE TO BE LOCATED IN THE VERTICAL

DUCT AT FLOOR TO FLOOR PENETRATION.

GOVERNMENT TO FURNISH STAND-ALONE

DEHUMIDIFIER.

24"x16" RETURN DUCT DOWN FROM SECOND

FLOOR. SEE A1/MH103 FOR CONTINUATION. FIRE

DAMPERS ARE TO BE LOCATED IN THE VERTICAL

DUCT AT FLOOR TO FLOOR PENETRATION.

26"/16" SUPPLY DUCT DOWN FROM SECOND

FLOOR. SEE A1/MH103 FOR CONTINUATION. FIRE

DAMPERS ARE TO BE LOCATED IN THE VERTICAL

DUCT AT FLOOR TO FLOOR PENETRATION.

ATFP EMERGENCY HVAC SHUTDOWN SWITCH.

PROVIDE RED-BUTTON TYPE WITH ENCLOSED

COVER AND KEYED RESET. PROVIDE DISTINCT

IDENTIFICATION LABEL ("HVAC EMERGENCY

SHUTDOWN") OF A DIFFERENT COLOR THAN THE

FIRE ALARM PULL STATIONS.

SIDEWALL TRANSFER DUCT. SEE DETAIL

B1/M-504.

10 TRANSFER DUCT. SEE DETAIL A1/M-504.

PROVIDE LOCKABLE ENCLOSURE FOR MANUAL

EXHAUST FAN ACTIVATION SWITCH. SWITCH

SHALL BE DISABLED BY DEFAULT. PROVIDE

SIGNAGE THAT INDICATES "FIRE SUPPRESSION

EXHAUST SYSTEM - FIRE DEPARTMENT USE

ONLY". COORDINATE ROUGH-IN LOCATION WITH

OTHER TRADES PRIOR TO INSTALLATION.

BLANK OFF AND INSULATE INACTIVE PORTIONS

OF LOUVER. MINIMUM EXHAUST DUCT OPENING

THROUGH LOUVER: 12" X 12". COORDINATE

LOUVER INSTALLATION WITHIN EXISTING

WINDOW OPENING.

PROVIDE 1/2"x1/2" WIRE MESH COVER ON DUCT

OPENING.

2420 22

A

B

D

C

E

F

G

H

19a

VAV-3-108

VAV-3-107

VAV-3-106

VAV-3-104

VAV-3-105

VAV-3-103

VAV-3-102

VAV-3-101

A

A

A

A

A

A

A

A

120 A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

C

C

C

C

C

C

I

C

C

C

C

C

C

10"x10"

8"x8"

8"x8"

8"x6"

8"x6"

6"x6"

18"x10" 6"x6"

"x

10"x10"

D

"x

D

D

"x

12"x10"

"Ø

"Ø

"Ø

"Ø

"x

8"x8"

"Ø 6"Ø

6"Ø

6"Ø

14"x12"

12"x12"

10"x10"

8"x8"

"x

6"Ø

8"Ø8 "Ø

"Ø6 "Ø

"Ø

10"x10"

"x

"x

"x

"Ø

8"Ø

8"Ø

10"Ø

8"Ø

8"Ø

8"Ø

14"x14"

10"Ø

10"Ø

"x

"x

10"Ø

"Ø

14"x12"

12"x12"

12"x10"

"Ø

"Ø

"Ø

8"Ø

"Ø

38"/24"

24"/16" 12"Ø

20"x14" 22"x16"

16"x12"

D

10"x8"

"x

"x

D

10"x8"

"x

"x

34"x12"

32"x16"

ACC-1

DSCU-1

8"x8"

"Ø

10"x10"

"Ø

"x

46"x22"

22"x16"

M-403 A1

10"Ø

14"x14"

8"x8"

E

E

E

8"x8"

6"x8"

8"x8" 6"x6"

10"x12"

FIN/ REC CORRIDOR

SHARED TESTING

EDUCATION &

TRAINING OFFICE

RECRUITING

STORAGE

107A

RECRUITING OPEN

OFFICE

RECRUITING

SUPERVISOR

RETENTION

102A

ID CARDS

FINANCE C/S OFC

103A

FSS C/S

FINANCE OPEN

OFFICE

WOMEN

122 EAST STAIR

121 STORAGE

JAN

FSS OPEN OFFICE

FSS CORRIDOR

PPE TRAINING BAG

STORAGE

OPERATIONS

OFFICERS

COMMANDER

PERSONNEL SUPER

FSS HUDDLE

110A

CEM

RECRUITING

CONSULT

FINANCIAL

MANAGEMENT

OFFICER

"x

HUDDLE / STORAGE

6"x6" E

B

"x

D

24"x12"

LACTATION

120A

EUH-5

EUH-3

BUFFER TANK

F -

C

12"x12"

M A

TC

H

L

IN

E

S E

E A

1/ M

H

A

I

6"Ø

6"x6"

6"Ø

6"Ø

6"Ø

10"Ø

"Ø

"Ø

10"Ø

8"Ø

EAST VEST

102B

16"x16" UP

16"Ø

16"Ø

8"Ø

10"Ø

16"Ø

10"Ø

INSTALLATION

PERSONNEL

READINESS

118A

14"x12"

C

275 10"x10"

8"x8"

C

C

65 8"x8"

6"x6" 6"x6"

"Ø

10"x10"

A

12' 13'10' 15'9'

EUH-1

ELECTRICAL

EF-6

L-6

L-5

T

12"x12"

MD

MD12"x12"55

KEY PLAN

SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 8 168

1/8"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:1

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MH102

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L H

V A

C P

L A

N

F

IR

S T

F L O

O R

A R

E A

B

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND

ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND HVAC

DESIGN CRITERIA.

SCALE: 1/8" = 1'-0"A1

HVAC PLAN - FIRST FLOOR AREA B

SCALE: 1/8" = 1'-0"B4

HVAC PLAN - ELECTRICAL ROOM

24"x22" RETURN DUCT DOWN FROM SECOND FLOOR.

SEE A1/MH104 FOR CONTINUATION. FIRE DAMPERS

ARE TO BE LOCATED IN THE VERTICAL DUCT AT

FLOOR TO FLOOR PENETRATION.

28"Ø SUPPLY DUCT UP TO SECOND FLOOR. SEE

A1/MH104 FOR CONTINUATION. FIRE DAMPERS ARE

TO BE LOCATED IN THE VERTICAL DUCT AT FLOOR

TO FLOOR PENETRATION

12"x12" EXHAUST DUCT UP TO SECOND FLOOR. SEE

A1/MH104 FOR CONTINUATION. FIRE DAMPERS ARE

TO BE LOCATED IN THE VERTICAL DUCT AT FLOOR

TO FLOOR PENETRATION.

ATFP EMERGENCY HVAC SHUTDOWN SWITCH.

PROVIDE RED-BUTTON TYPE WITH ENCLOSED

COVER AND KEYED RESET. PROVIDE DISTINCT

IDENTIFICATION LABEL ("HVAC EMERGENCY

SHUTDOWN") OF A DIFFERENT COLOR THAN THE

FIRE ALARM PULL STATIONS.

PROVIDE 1/2"x1/2" WIRE MESH COVER ON DUCT

OPENING.

4 6 7 8 9 16

13'10' 15'

A

B

D

C

E

L'

K'

J'

H'

G'

F'

6a

F

G

H

9' 16'

E'

VAV-2-206

VAV-1-206

VAV-1-201

VAV-1-202

VAV-1-203

VAV-1-204

VAV-1-205

VAV-3-208

VAV-2-204

VAV-2-201

CONTRACTING

SUPER

229A

CONTRACTING

OPEN OFFICE

MSG OPEN OFFICE

MSG COMMANDER

230B MSG DEPUTY

COMMANDER

230C

MSG FIRST

SERGEANT

230E

MSG CHIEF

230D

MULTIMEDIA

STUDIO/STORAGE

231B

C

"x

C

8"x8"

C

C

8"x8"

6"x6"

"x

COMMAND POST

224B

SECOND FLOOR

CONFERENCE

WOMEN

MEN

MSG CORRIDOR

C

10"x10"

"x

8"x8"

PUBLIC AFFAIRS

OIC

231APUBLIC AFFAIRS

ADMIN OPEN

OFFICE

10"x10"

12"x12"

"x

6"x6"

D

D

20"x14"

D

24"x14"

D

D

D

A

A

A

120 A

A

A

120 A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

C

8"x6"

12"x12" C

C

"x

A

A

A

A

A

A

A

A

C

8"x8"

"x

"x

16"x14"

16"x14"

20"x16"

"x

14"x12"

"x

10"Ø 10"Ø

10"Ø

10"Ø

10"Ø

8"Ø

16"x12"

"Ø

"Ø

"Ø1 "Ø

"Ø

6"Ø

6"x10"

6"Ø

"Ø

10"x12" 10"Ø

10"Ø10"Ø

12"x10" 8"x8"

10"x10"

"Ø

"Ø

"Ø

"Ø12"x8"

12"x10" 6 "Ø

6"Ø

"Ø

8"Ø

8"Ø 8"Ø

"Ø

12"x10"8"x10"

"Ø

"Ø

"Ø

"Ø 8"Ø

IGI 1

IGI 2

COMMAND

CORRIDOR

JAG 2

JAG 1

ASSEMBLY

LANDING

UPPER LANDING

TELECOM ROOM

WOMEN

MEN

SMALL

CONFERENCE

BREAK ROOM

C

C

6"x6"

8"x8"

6"x6"

6"x8"

"x

C

C

8"x8"

E

E

380 10"x10"

"Ø

H

22"/14"

16"x14" 20"x20"

VAV-2-205

VAV-2-203

VAV-2-202

12"Ø

12"Ø

14"x14"

34"/18"

28"/14"

20"/12"

AHU-4

8"Ø

10"Ø

14"x14"

18"x18"

14"x14"

10"Ø 10"Ø

10"Ø

10"Ø

M D

12"x12"

6"Ø

20"x22"

14"x12"

DSS-3

L-4

L-2

MULTI PURPOSE

ROOM A

160A

MULTI PURPOSE

ROOM B

160B

MD

C

"x

24"x16" 26"/16"

E

E

8"x6"

8"x6"

D

A

12"x14"

"Ø

10"x8"

A

6"Ø

16"x16"

"x

"x

10"Ø

12"x12"

14"x14"

"x

32"/20"

14"x14"

C

C

STORAGE

160D

26"/18"

MD

B

8"x6"

B

B

B

B

"x

"x

"x

"x

12"x12"

10 11

TRAP

224A

CMD POST OFC 2

224E

CMD POST OFC 1

224D

CONTROL PANEL

224C

H

C

C

6"Ø 12

D

D

58"x30"

MD

EF-10

MD

A

10"Ø

10"Ø

D

B

B

8"x6"

8"x8"

C

C

F

F

10"x10" 10"x10"

14"Ø

10"Ø

14"Ø

10"Ø

10"Ø

14"Ø

AV CLOSET

160C

14"Ø

M A

TC

H

L

IN

E

S E

E A

1/ M

H

L-8

16"x10"

10"Ø

"Ø8 "Ø10"Ø8"Ø

8"Ø

8"Ø

MOD

6"x8"

12"x10"

DAMPER IN

VERTICAL

DROP

DAMPER IN

VERTICAL

DROP

40"x26"

56"x84"

50"x26"

44"x24"

48"x60"

MD

L-10

B

12"x6"

18"x18" RLA UP 16

12"x24" RLA

UP/DN

18"x18" RLA UP

OFFSET BETWEEN

EXST. STRUCTURE

10"x8"

B

8"x6"

KEYNOTES:

KEY PLAN

SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 8 168

1/8"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:2

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MH103

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L H

V A

C P

L A

N

S E

C O

N D

F L O

O R

A R

E A

A

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

SCALE: 1/8" = 1'-0"A1

HVAC PLAN - SECOND FLOOR AREA A

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES

AND ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND

HVAC DESIGN CRITERIA.

52"/20" SUPPLY DUCT UP FROM FIRST FLOOR. SEE

A1/MH101 FOR CONTINUATION. FIRE DAMPERS ARE

TO BE LOCATED IN THE VERTICAL DUCT AT FLOOR

TO FLOOR PENETRATION

20"x20" RETURN DUCT DOWN TO FIRST FLOOR.

SEE A1/MH101 FOR CONTINUATION. FIRE DAMPERS

ARE TO BE LOCATED IN THE VERTICAL DUCT AT

FLOOR TO FLOOR PENETRATION.

30"/20" SUPPLY DUCT UP FROM FIRST FLOOR. SEE

A1/MH101 FOR CONTINUATION. FIRE DAMPERS ARE

TO BE LOCATED IN THE VERTICAL DUCT AT FLOOR

TO FLOOR PENETRATION

8"x10" EXHAUST DUCT UP TO EF-7. SEE A1/MH120

FOR CONTINUATION.

12"x12" EXHAUST DUCT UP TO EF-2. PROVIDE 1/2"x1/2" WIRE MESH COVER ON DUCT OPENING.

SEE A1/MH120 FOR CONTINUATION.

16"x16" EXHAUST DUCT UP TO EF-4. SEE A1/MH120

FOR CONTINUATION.

26"/16" SUPPLY DUCT DOWN TO FIRST FLOOR. SEE

A1/MH101 FOR CONTINUATION. FIRE DAMPERS ARE

TO BE LOCATED IN THE VERTICAL DUCT AT FLOOR

TO FLOOR PENETRATION.

58"x30" RETURN DUCT DOWN TO FIRST FLOOR.

SEE A1/MH101 FOR CONTINUATION. FIRE DAMPERS

ARE TO BE LOCATED IN THE VERTICAL DUCT AT

FLOOR TO FLOOR PENETRATION.

24"x16" RETURN DUCT DOWN TO FIRST FLOOR.

SEE A1/MH101 FOR CONTINUATION. FIRE DAMPERS

ARE TO BE LOCATED IN THE VERTICAL DUCT AT

FLOOR TO FLOOR PENETRATION.

12"x12" EXHAUST DUCT UP FROM FIRST FLOOR.

SEE A1/MH101 FOR CONTINUATION. FIRE DAMPERS

ARE TO BE LOCATED IN THE VERTICAL DUCT AT

FLOOR TO FLOOR PENETRATION.

10"x12" OUTSIDE AIR DUCT DOWN TO FIRST FLOOR.

SEE A1/MH402 FOR CONTINUATION. FIRE DAMPERS

ARE TO BE LOCATED IN THE VERTICAL DUCT AT

FLOOR TO FLOOR PENETRATION.

ATFP EMERGENCY HVAC SHUTDOWN SWITCH.

PROVIDE RED-BUTTON TYPE WITH ENCLOSED

COVER AND KEYED RESET. PROVIDE DISTINCT

IDENTIFICATION LABEL ("HVAC EMERGENCY

SHUTDOWN") OF A DIFFERENT COLOR THAN THE

FIRE ALARM PULL STATIONS.

13 SIDEWALL TRANSFER DUCT. SEE DETAIL B1/M-504.

PROVIDE LOCKABLE ENCLOSURE FOR MANUAL

EXHAUST FAN ACTIVATION SWITCH. SWITCH

SHALL BE DISABLED BY DEFAULT. PROVIDE

SIGNAGE THAT INDICATES "FIRE SUPPRESSION

EXHAUST SYSTEM - FIRE DEPARTMENT USE ONLY".

COORDINATE ROUGH-IN LOCATION WITH OTHER

TRADES PRIOR TO INSTALLATION.

PROVIDE 1/2"x1/2" WIRE MESH COVER ON DUCT

OPENING.

RELIEF DUCT IN CHASE UP TO ROOF HOOD.

TRANSITION TO FULL SIZE OF ROOF HOOD

CONNECTION OPENING IN ROOF CURB. SEE

A1/MH120 FOR CONTINUATION.

2420 22

A

B

D

C

E

F

G

H

19a

VAV-3-207

VAV-3-206

VAV-3-204

VAV-3-205

VAV-3-203

VAV-3-202

VAV-3-201

A

A

A

A

130 A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

12"x12"12"x10"

8"Ø

"Ø

10"Ø

8"Ø

6"Ø

12"x14"

12"x10"

"Ø1

"Ø

"Ø

"Ø

6"Ø

8"x8"

"Ø

8"Ø 8"Ø

8"Ø8"Ø

12"x12"

"Ø 1

"x

12"x6" 6"Ø

6"Ø6"Ø6 "Ø

"x

6"Ø 8"Ø

8"Ø

8"Ø

COMMAND CHIEF

MASTER SERGEANT

211E

COMMAND JAG (3)

211F

COMMAND SUITE

CLOS

211D

WING COMMANDER

211C

EXECUTIVE

SUPPORT

211B

VICE COMMANDER

211A

COMMAND

CONFERENCE

DDR

HRA

INSPECTOR

GENERAL

WING PLANS

OFFICER

SAFETY OFFICER

OPEN OFFICE

E/O 2

E/O 1

WOMEN

MEN

EAST STAIR

C

C

"x

6"x6"

"x

C

C

"x

6"x6"

"x

IGQ

"x

C

65 6"x6"

C

C

8"x8"

C

"x

C

C

C

C

8"x6"6"x6"

"x

C

"x

D

"x

D

"x

D

D

10"x8"

D

20"/14"

20"/14" 30"/14"

"x

14"x14" 18"x14"

"x

"x

E

E

12"x12"

10"x10"

10"x10"

"x

"x

20"x16"

18"x16"

12"x10"

10"Ø

30"/24" 12"x12"

"x

8"Ø

"x

8"x6"

IGI STAFF

205W

8"Ø

8"Ø 6"Ø

8"Ø

6"Ø

16"x16"

F

F

C

C

"Ø

6"Ø

6"x6"

24"x22"28"Ø 8"Ø

12"Ø

12"Ø

10"Ø

KEY PLAN

SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 8 168

1/8"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:3

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MH104

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L H

V A

C P

L A

N

S E

C O

N D

F L O

O R

A R

E A

B

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND

ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND HVAC

DESIGN CRITERIA.

SCALE: 1/8" = 1'-0"A1

HVAC PLAN - SECOND FLOOR AREA B

24"x22" RETURN DUCT DOWN TO FIRST FLOOR. SEE

A1/MH102 FOR CONTINUATION. FIRE DAMPERS ARE

TO BE LOCATED IN THE VERTICAL DUCT AT FLOOR

TO FLOOR PENETRATION.

28"Ø SUPPLY DUCT UP FROM FIRST FLOOR. SEE

A1/MH102 FOR CONTINUATION. FIRE DAMPERS ARE

TO BE LOCATED IN THE VERTICAL DUCT AT FLOOR

TO FLOOR PENETRATION.

14"x14" EXHAUST DUCT UP TO EF-5. SEE A1/MH120

FOR CONTINUATION.

12"x12" EXHAUST DUCT UP FROM FIRST FLOOR. SEE

A1/MH102 FOR CONTINUATION. FIRE DAMPERS ARE

TO BE LOCATED IN THE VERTICAL DUCT AT FLOOR

TO FLOOR PENETRATION.

RELIEF DUCT IN CHASE UP TO ROOF HOOD.

TRANSITION TO FULL SIZE OF ROOF HOOD

CONNECTION OPENING IN ROOF CURB. SEE

A1/MH120 FOR CONTINUATION.

6 SIDEWALL TRANSFER DUCT. SEE DETAIL B1/M-504.

1 2 4 6 7 8 9 16 17 18 19 21 23 24

12' 13'10' 15'

20 22

A

B

D

C

E

L'

K'

J'

H'

G'

F'

6a

F

G

H

9' 16'

E'

19a

EF-1

EF-3

EF-5

EF-4

EF-2

EF-7

2 2RH-1

RH-4

RH-2

RH-3

KEY PLAN

SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 16 3216

1/16"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:3

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MH120

100% B3 SUBMITTAL

R O

O F

H V

A C

P L A

N

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND

ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND HVAC

DESIGN CRITERIA.

6"Ø GOOSENECK COMBUSTION AIR DOWN TO

BOILERS. SEE A1/M-403 FOR CONTINUATION.

8"Ø EXHAUST DUCT UP FROM BOILERS. SEE A1/M-403

FOR CONTINUATION.

SCALE: 1/16" = 1'-0"A1

MECHANICAL ROOF PLAN

6 7 8 9 16

12'10' 15'

A

B

D

C

E

K'

J'

H'

G'

F'

6a

F

G

H

9' 16'

E'

VAV-1-101

PPE TRAINING BAG

STORAGE

MECHANICAL

COMM CORRIDOR

OPERATIONS CHIEF

COMMANDER

RECORDS STAGING/

STORAGE

SECURE STORAGE

(CRYPTO)

PLANS &

RESOURCES CHIEF

STAN/EVAL

SECOND OFFICER

CEM

UTC PREVENTIVE

MAINTENANCE

149 COMM OPEN OFFICE

SF XO/NCO

SF OPEN OFFICE

SF/ COMM

CORRIDOR

SF COMMANDER

SF FIRST

SERGEANT

LAW

ENFORCEMENT

DESK

INFORMATION

PROTECTION CHIEF

DATA CENTER

COMM C/S

155PROGRAM

MANAGEMENT

CHIEF OF SECURITY

SHARED WAITING

ROOM

LOWER LANDING

010 BUDGET OFFICE

W/C 1

W/C 2

FLIGHT CHIEFS

HOTEL W/S

VAV-1-103

VAV-1-102

VAV-1-104

VAV-1-105

VAV-1-106

VAV-1-108

VAV-1-107

VAV-3-109

VAV-2-103

VAV-2-104

VAV-2-102

VAV-2-101

DSS-1

DSCU-3

RS

RL

DSCU-1

DSCU-2

ELEV MACHINE RM

DSS-2

RL

RS

HP-1

RS

RL

MECHANICAL

VAULT

016A

TRAINING ROOM

WEAPONS

CLEARING

EQUIPMENT

LOCKERS

WEAPONS

MAINTENANCE

CATM NCOIC

021A OPERATIONS

SUPER

WS

PPE TRAINING BAG

STORAGE

SUPPLY MOBILITY

MANAGEMENT

WS

SF/ CATM

CORRIDOR

CATM ADMIN

2" HWS

2" HWR

2" HWS

2" HWR

2" HWS

2" HWR

2" HWR

2" HWS 2" HWR

2" HWS

3" HWR

3" HWS

2 1/2" HWR

2 1/2" HWS

CRAC-1

CRAC-2

CRCU-1 CRCU-2

RL

RS

RL

RS

M-402 A3

M-401 A3

2 1/2" CHWS

2 1/2" CHWR

2 1/2" CHWS

2 1/2" CHWR

2 1/2" CHWS

2 1/2" CHWR

3" CHWR

3" CHWS

2 1/2" CHWS

2 1/2" CHWR

2 1/2" CHWS

2 1/2" CHWR

3" CHWR

3" CHWS

3 1/2" HWS

3 1/2" HWR

3" CHWS

3" CHWR

T

T

T

T T

T T

T

T

T

T

T

T

T

CD

CD

CD

CD

CO

CO

CO

T

T

2" HWR

2" HWS

VEST

101A

COMM OPEN OFFICE

ITE

STAGING/STORAGE

M A

TC

H

L

IN

E

S E

E A

1/ M

P

T

KEYNOTES:

KEY PLAN

SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 8 168

1/8"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:4

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MP101

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L P

IP

IN

G P

L A

N

F

IR

S T

F L O

O R

A R

E A

A

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

SCALE: 1/8" = 1'-0"A1

HYDRONIC PIPING FLOOR PLAN - FIRST FLOOR AREA A

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND

ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND HVAC

DESIGN CRITERIA.

1 1" HWS AND HWR UP TO FLOOR ABOVE.

RL, RS, AND CONDENSATE DOWN FROM SECOND

FLOOR. SEE MP103 FOR CONTINUATION. SIZE PER

MANUFACTURER'S RECOMMENDATION.

RL, RS, AND CONDENSATE, SIZE PER

MANUFACTURER'S RECOMMENDATION. INSULATION

EXPOSED TO WEATHER SHALL HAVE ALUMINUM

JACKET.

EXTEND CONDENSATE DRAIN LINE FULL SIZE OF

CONNECTION ON UNIT WITH P-TRAP. ROUTE DOWN

INSIDE WALL AND THROUGH EXTERIOR WALL WITH

PIPE SLEEVE TO APPROXIMATELY 6" ABOVE

EXTERIOR GRADE. TURN DOWN WITH 90 DEGREE

ELBOW AND PROVIDE SPLASHBLOCK.

PROVIDE DIFFERENTIAL PRESSURE SENSOR IN

PIPING AT APPROXIMATE LOCATION INDICATED

BETWEEN THE FINAL TWO COILS IN THE PIPING

SYSTEM.

PROVIDE EXPANSION LOOP ON SUPPLY AND

RETURN PIPES AT APPROXIMATE LOCATION

INDICATED. REFER TO DETAIL B1/M-502.

2420 22

A

B

D

C

E

F

G

H

19a

VAV-3-108

VAV-3-107 VAV-3-106

VAV-3-105

VAV-3-103

VAV-3-104

VAV-3-102

VAV-3-101

RECRUITING

STORAGE

107A

RECRUITING

CONSULT

EDUCATION &

TRAINING OFFICE

SHARED TESTING

CEM

EAST VEST

102B

FIN/ REC CORRIDOR

RETENTION

102A

RECRUITING

SUPERVISOR

FINANCE C/S OFC

103A

FSS C/S

ID CARDS

FINANCE OPEN

OFFICE

FINANCIAL

MANAGEMENT

OFFICER

WOMEN

EAST STAIR

STORAGE

JAN

FSS OPEN OFFICE

COMMANDER

OPERATIONS

OFFICERS

PPE TRAINING BAG

STORAGE

HUDDLE / STORAGE

ACC-1

3 1/2" HWR

3 1/2" HWS

3 1/2" HWS

3 1/2" HWR

3 1/2" HWS

3 1/2" HWR

3 1/2" HWR

3 1/2" HWS

M-403 A3

3" CHWS

3" CHWR

3" CHWR

3" CHWS

3" CHWR

3" CHWS

4" CHWR U/G

4" CHWS U/G

T

T

T

PERSONNEL SUPER

FSS HUDDLE

110A

RECRUITING OPEN

OFFICE

T

T

T T

T

BUFFER TANK

LACTATION

120A

M A

TC

H

L

IN

E

S E

E A

1/ M

P

CHILLED WATER PUMPS INCLUDED

IN PACKAGED CHILLER SKID

2 1/2" CHWS

INSTALLATION

PERSONNEL

READINESS

118A

KEY PLAN

SCALE: = 1'-0"

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

STAMP/SEAL

PLAN NORTH

0 8 168

1/8"

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

B o x

S yr a c u s e

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:4

:5

A M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

MP102

100% B3 SUBMITTAL

M E

C H

A N

IC

A

L P

IP

IN

G P

L A

N

F

IR

S T

F L O

O R

A R

E A

B

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

M T

R

R C

C

W W

C

M

A R

C H

GENERAL NOTES:

1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND

ABBREVIATIONS.

2. REFER TO M-002 FOR MECHANICAL LEGENDS AND HVAC

DESIGN CRITERIA.

SCALE: 1/8" = 1'-0"A1

HYDRONIC PIPING FLOOR PLAN - FIRST FLOOR AREA B

1 1 1/2" HWS AND HWR UP TO FLOOR ABOVE.

2 1/2" CHILLED WATER BYPASS VALVE ASSEMBLY AND

APPURTENANCES.

PROVIDE BUFFER TANK HEAT TRACE. SEE

ELECTRICAL FOR DEDICATED POWER CIRCUIT.

PROVIDE HEAT TRACE AT 5 WATTS PER LINEAR FOOT

FOR EXPOSED CHILLED WATER PIPE ABOVE GRADE.

SEE ELECTRICAL FOR DEDICATED POWER CIRCUIT.

PROVIDE UNDERGROUND, FACTORY INSULATED

CHILLED WATER PIPING.

PROVIDE GALVANIZED PIPING SLEEVE BELOW

BUILDING SLAB AND STUB UP ABOVE FINISHED

FLOOR FOR CHILLED WATER PIPING ENTRANCE INTO

BUILDING. FACTORY INSULATED CHILLED WATER

PIPING SHALL EXTEND NO LESS THAN 0'-6" AFF.

PROVIDE EXPANSION LOOP ON SUPPLY AND RETURN

PIPES AT APPROXIMATE LOCATION INDICATED.

REFER TO DETAIL B1/M-502.

4 6 7 8 9 16

12' 13'10' 15'

A

B

D

C

E

L'

K'

J'

H'

G'

F'

6a

F

G

H

9' 16'

E'

VAV-2-201

VAV-2-204

VAV-2-206

DSS-3

RL

RS

VAV-3-208

VAV-1-206

VAV-1-204

VAV-1-205

VAV-1-203

VAV-1-202

VAV-1-201

SECOND FLOOR

CONFERENCE

MULTIMEDIA

STUDIO/STORAGE

231B

MSG OPEN OFFICE

MSG CORRIDOR

MSG COMMANDER

230B

CONTRACTING

SUPER

229A

CONTRACTING

OPEN OFFICE

MSG FIRST

SERGEANT

230E

MSG CHIEF

230D

WOMEN

MEN

227 COMMAND POST

224B

PUBLIC AFFAIRS

ADMIN OPEN

OFFICE

PUBLIC AFFAIRS

OIC

231A

UPPER LANDING

ASSEMBLY

LANDING

TELECOM ROOM

JAG 2

JAG 1

IGI 1

IGI 2

IGI STAFF

205W

JAG OPEN OFFICE

COMMAND

CORRIDOR

BREAK ROOM

SMALL

CONFERENCE

STORAGE

160D

MULTI PURPOSE

ROOM A

160A

AHU-4

VAV-2-202

VAV-2-205

VAV-2-203

3/4" HWS

3/4" HWR

2" HWS

2" HWR

RL

RS

MULTI PURPOSE

ROOM B

160B

1" HWR

1" HWS

T

T

T T

T

T

T

T

T T

T

MSG OPEN OFFICE

CD

CD

T

T

T

MSG DEPUTY

COMMANDER

230C

CO

CONTROL PANEL

224C

CMD POST OFC 1

224D

CMD POST OFC 2

224E

TRAP

224A

T

CO

1 1/2" HWR

1 1/2" HWS

WEST STAIR

M…