About this file
This document package includes construction drawings and specifications for a federal construction contract solicitation along with details of the opportunity. The drawings show demolition and renovation plans for the electrical, mechanical, and plumbing systems at the two-story 43,029 square foot Operations and Training Facility, Building 902 at Niagara Falls International Airport in New York. The solicitation is for the renovation of this facility and has a projected value between $10 million and $25 million. It is identified as a competitive 8(a) small business set-aside with a NAICS code of 236220 and $45 million size standard. The pre-bid conference and site visit are encouraged for those intending to submit a bid. The solicitation will be posted at SAM.gov and the award will be made based on price to the responsible bidder whose bid conforms to the invitation. Funds are not presently available but are anticipated to be available by September 30, 2023. This project is on the New York Army National Guard's priority list to award if funds become available within a reasonable price range. No contract will be awarded until funds are appropriated.
View the file
Other files for this federal contract opportunity
Show all 29
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LP1-8 LP1-9
LP1-7
LPDP1
LPDP2
LP1-6
OFFICE
122A
PUBLIC
RELATIONS
JOINT / SHARED
STORAGE
RECRUITING
CUSTOMER
SERVICE
SCALE: = 1'-0"
1 2 3 4 5
A
B
C
D
SHEET ID
P a rk w a y L a n e
S u it e
P e a c h tr e e C o rn e rs
G
A
P h o n e
-7
F a x
(6
-7
P O
N D
J O
B
S
IZ
E
A N
S I D
F
IL
E N
A M
E
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
D A
T E
D E
S C
R
IP
T
IO
N M
A R
K
PLAN NORTH
0 16 3216
1/16"
Q P
K D
E S
IG
N
S o u th
S a lin a S tr e e t
S u it e
P
O B o x
S y ra c u s e
N Y
-0
Q P
K J
O B
ORIGINAL SHEET SIZE - ANSI D (22" X 34")
/1
/2
:3
:0
P M
B
IM
/1
N
Y A
N G
N ia g a ra
F a lls R e p a ir O
T
F a c ili ty /1
N
Y A
N G
N
IA
G
A R
A M
E P
F P
B v
.r v t
100% B3 SUBMITTAL
B902
E L E
C T
R
IC
A L D
E M
O L
IT
IO
N
P L A
N
R E
N O
V A
T E
O P
E R
A T
IO
N
S A
N D
T R
A
IN
IN
G
F A
C
IL
IT
Y
B
N E
W Y
O R
K A
IR
N
A T
IO
N
A L G
U A
R D
N
IA
G A
R A
F A
L L S
A
IR
R E
S E
R V
E S
T A
T
IO
N
N E
W Y
O R
K A
IR
N
A T
IO
N
A L G
U A
R D
G L K
S C
M
S C
M
T E
H
M
A R
C H
ED105-01
1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,
ABBREVIATIONS & LEGEND.
1. DEMOLISH EXISTING UNIT HEATER CONDUCTORS AND
CONDUIT BACK TO SOURCE PANEL.
SCALE: 1/16" = 1'-0"A1
MECHANICAL POWER DEMOLITION PLAN - B902 FIRST FLOOR OVERALL
GENERAL NOTES:
KEYNOTES:#
S M
S M
S M
S M
S M
S M
OFFICE
120A
STORAGE
120B
SECURITY FORCES
OFFICE
120C
JOINT / SHARED
STORAGE
STORAGE
SHARED BREAK
ROOM
FINANCE
FINANCE
RECRUITING
STORAGE
OFFICE
STORAGE
FSS
OFFICE
105A
E-125-01
B4
E-125-01
A4
LP1-9LP1-8
LP1-7
LPDP1
LPDP2
LP1-6
EUH-03
EUH-01
EUH-02
PUBLIC RELATIONS
CHIEF OF SAFETY
122A
RECRUITING
CUSTOMER
SERVICE
ID CARDS
100A
DSS-01
DSS-02
LP1-7-29,31
LP1-7-25,27
PUBLIC RELATIONS
CHIEF OF SAFETY
122A
DSS-03 DSHP-03
DSHP-02
DSHP-01
LP1-7-33,35
RECRUITING
SCALE: = 1'-0"
1 2 3 4 5
A
B
C
D
SHEET ID
P a rk w a y L a n e
S u it e
P e a c h tr e e C o rn e rs
G
A
P h o n e
-7
F a x
(6
-7
P O
N D
J O
B
S
IZ
E
A N
S I D
F
IL
E N
A M
E
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
D A
T E
D E
S C
R
IP
T
IO
N M
A R
K
PLAN NORTH
0 16 3216
1/16"
Q P
K D
E S
IG
N
S o u th
S a lin a S tr e e t
S u it e
B o x
S y ra c u s e
-0
Q P
K J
O B
ORIGINAL SHEET SIZE - ANSI D (22" X 34")
/1
/2
:3
:0
P M
B
IM
/1
N
Y A
N G
N ia g a ra
F a lls R e p a ir O
T
F a c ili ty /1
N
Y A
N G
N
IA
G
A R
A M
E P
F P
B v
.r v t
100% B3 SUBMITTAL
B902
M E
C H
A N
IC
A
L P
O W
E R
P L A
N
R E
N O
V A
T E
O P
E R
A T
IO
N
S A
N D
T R
A
IN
IN
G
F A
C
IL
IT
Y
B
N E
W Y
O R
K A
IR
N
A T
IO
N
A L G
U A
R D
N
IA
G A
R A
F A
L L S
A
IR
R E
S E
R V
E S
T A
T
IO
N
N E
W Y
O R
K A
IR
N
A T
IO
N
A L G
U A
R D
G L K
S C
M
S C
M
T E
H
M
A R
C H
E-125-01
1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,
ABBREVIATIONS & LEGEND.
2. REFER TO E-625-01 FOR MECHANICAL EQUIPMENT
CONNECTION SCHEDULE.
GENERAL NOTES:
SCALE: 1/16" = 1'-0"A1
MECHANICAL POWER PLAN - B902 FIRST FLOOR OVERALL
SCALE: 3/16" = 1'-0"B4
ENLARGED MECHANICAL POWER -
122 SAFETY & PUBLIC RELATIONS
SCALE: 3/16" = 1'-0"A4
ENLARGED MECHANICAL POWER - 123 RECRUITING
SCALE: = 1'-0"3/16"
0 4 8 124
1. MOUNT DISCONNECT ABOVE CEILING, ADJACENT TO UNIT.
KEYNOTES:#
1 2 3 4 5
A
B
C
D
SHEET ID
P a rk w a y L a n e
S u it e
P e a c h tr e e C o rn e rs
G
A
P h o n e
-7
F a x
(6
-7
P O
N D
J O
B
S
IZ
E
A N
S I D
F
IL
E N
A M
E
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
D A
T E
D E
S C
R
IP
T
IO
N M
A R
K
Q P
K D
E S
IG
N
S o u th
S a lin a S tr e e t
S u it e
B o x
S y ra c u s e
-0
Q P
K J
O B
ORIGINAL SHEET SIZE - ANSI D (22" X 34")
/1
/2
:3
:0
P M
B
IM
/1
N
Y A
N G
N ia g a ra
F a lls R e p a ir O
T
F a c ili ty /1
N
Y A
N G
N
IA
G
A R
A M
E P
F P
B v
.r v t
100% B3 SUBMITTAL
B902
E L E
C T
R
IC
A L S
C H
E D
U L E
S
R E
N O
V A
T E
O P
E R
A T
IO
N
S A
N D
T R
A
IN
IN
G
F A
C
IL
IT
Y
B
N E
W Y
O R
K A
IR
N
A T
IO
N
A L G
U A
R D
N
IA
G A
R A
F A
L L S
A
IR
R E
S E
R V
E S
T A
T
IO
N
N E
W Y
O R
K A
IR
N
A T
IO
N
A L G
U A
R D
G L K
S C
M
S C
M
T E
H
M
A R
C H
E-625-01
1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,
ABBREVIATIONS & LEGEND.MECHANICAL EQUIPMENT CONNECTION SCHEDULE
UNIT VOLTAGE
NUMBER
OF POLES KVA MCA HP STARTER DISCONNECT FEEDER SIZE PANEL CIRCUIT
LOCATION
NOTESNUMBER NAME
DSHP-01 208 V 2 1.83 kVA 11 A - MRS 2#12 & 1#12G, 3/4"C. LP1-7 13,15 121 SHARED STORAGE 2
DSHP-02 208 V 2 1.83 kVA 11 A - MRS 2#12 & 1#12G, 3/4"C. LP1-7 17,19 121 SHARED STORAGE 2
DSHP-03 208 V 2 1.83 kVA 11 A - MRS 2#12 & 1#12G, 3/4"C. LP1-7 21,23 121 SHARED STORAGE 2
DSS-01 208 V 2 0.17 kVA 1 A - FWE 2#12 & 1#12G, 3/4"C. LP1-7 13,15 122 SAFETY & PUB. REL. 1, 2
DSS-02 208 V 2 0.17 kVA 1 A - FWE 2#12 & 1#12G, 3/4"C. LP1-7 17,19 122 SAFETY & PUB. REL. 1, 2
DSS-03 208 V 2 0.17 kVA 1 A - FWE 2#12 & 1#12G, 3/4"C. LP1-7 21,23 123 RECRUITING 1, 2
EUH-01 120 V 1 1.50 kVA 16 A - FWE 2#12 & 1#12G, 3/4"C. LP1-7 32 100A ID CARDS 2
EUH-02 120 V 1 1.50 kVA 16 A - FWE 2#12 & 1#12G, 3/4"C. LP1-7 34 100 CUSTOMER SERVICE 2
EUH-03 120 V 1 1.50 kVA 16 A - FWE 2#12 & 1#12G, 3/4"C. LP1-7 36 100 CUSTOMER SERVICE 2
NOTES:
1. INDOOR DSS UNIT FED FROM ASSOCIATED OUTDOOR UNIT.
2. ALL CONDUCTORS FOR MECHANICAL AND PLUMBING EQUIPMENT SHALL BE COPPER. THE USE OF ALUMINUM CONDUCTORS TO FEED THIS EQUIPMENT
IS NOT PERMITTED.
NOTES: * PROVIDE NEW BREAKER
TOTAL EST. DESIGN CURRENT: 31 A
TOTAL LOAD: 3.71 3.71 3.71 TOTAL CONNECTED CURRENT: 31 A
-- 41 -- -- -- 0.00 0.00 -- -- -- 42 --
-- 39 -- -- -- 0.00 0.00 -- -- -- 40 --
37 SPARE 30 A 3 0.00 0.00 3 50 A A/C SHEET METAL SHOP (2 POLE) 38
-- 35 -- -- -- 0.11 1.50 1 20 A EUH-03 36 *
* 33 DSS-03 COND PUMP 20 A 2 0.11 1.50 1 20 A EUH-02 34 *
-- 31 -- -- -- 0.11 1.50 1 20 A EUH-01 32 *
* 29 DSS-02 COND PUMP 20 A 2 0.11 0.00 1 20 A EXHAUST 30
-- 27 -- -- -- 0.11 0.00 1 20 A LIGHTS 28
* 25 DSS-01 COND PUMP 20 A 2 0.11 0.00 1 20 A LIGHTS 26
-- 23 -- -- -- 1.00 0.00 -- -- -- 24 --
* 21 DSHP-03/DSS-03 20 A 2 1.00 0.00 -- -- -- 22 --
-- 19 -- -- -- 1.00 0.00 3 30 A SPARE 20
* 17 DSHP-02/DSS-02 20 A 2 1.00 0.00 -- -- -- 18 --
-- 15 -- -- -- 1.00 0.00 -- -- -- 16 --
* 13 DSHP-01/DSS-01 20 A 2 1.00 0.00 3 30 A PARTS WASHER HYDRELIC SHOP 14
11 SPARE 20 A 1 0.00 0.00 -- -- -- 12 --
9 SPARE 20 A 1 0.00 0.00 -- -- -- 10 --
7 SPARE 20 A 1 0.00 0.00 3 30 A SPARE 8
5 SPARE 20 A 1 0.00 0.00 1 20 A SPARE 6
3 SPARE 20 A 1 0.00 0.00 -- -- -- 4 --
1 SPARE 20 A 1 0.00 0.00 2 30 A LADIES ROOM HEAT 2
CKT CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION CKT
CONNECTED LOAD KVA
ENCLOSURE: NEMA 1 WIRES: 4
MOUNTING: FLUSH PHASES: 3
SUPPLY FROM: LPDP1 VOLTAGE: 208Y/120
LOCATION: MAINS RATING: 225A MCB MINIMUM BREAKER SCCR: 10,000 A
REVISED PANELBOARD SCHEDULE: LP1-7
1. CONTRACTOR SHALL VERIFY ALL EXISTING LOADS BEFORE
DISCONNECTING ANY CIRCUIT BREAKERS TO FEED NEW
EQUIPMENT.
2. EXISTING 30A/3P BREAKER TO BE REPLACED WITH NEW
20A/2P BREAKER.
3. EXISTING SPACE TO BE REPLACED WITH NEW 20A/1P
BREAKER.
GENERAL NOTES:
KEYNOTES:#
MAIN HALL NORTH END
2 3
| ED105-01 - ELECTRICAL DEMOLITION PLAN |
| E-125-01 - MECHANICAL POWER PLAN |
| E-625-01 - ELECTRICAL SCHEDULES |
File details come from the government source that posted it. Updated .