About this file

This file package includes architectural drawings and specifications for the construction of a new climatic chamber building at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, New Hampshire. The drawings depict the building elevations, sections, and wall details. Mechanical, electrical, and structural components are also shown. The related federal contract opportunity is solicitation W912WJ20B0008 from the Department of the Army Corps of Engineers Engineering District New England seeking offers for the construction of the climatic chamber building in accordance with the specifications and drawings. The single award firm-fixed-price design-bid-build contract has an unspecified period of performance for the base work and a total estimated value above $7 million.

View the file

Other files

File Type Posted
Bid Abstract.pdf PDF
Bid Summary_W912WJ20B0008.pdf PDF
Amendment 0006.pdf PDF
Amend 0005_13 34 19.pdf PDF
Amendment 0005.pdf PDF
Amend 0004_11 01 00.pdf PDF
Amendment 0004.pdf PDF
Amend 0004_13 34 19.pdf PDF
Amend 0003_A-310.pdf PDF
Amend 0003_03 30 00.pdf PDF
Amend 0003_S-301.pdf PDF
Amend 0003_P-501.pdf PDF
Amend 0003_CD-101.pdf PDF
Amend 0003_C-503.pdf PDF
Amend 0003_A-601.pdf PDF
Amendment 0003.pdf PDF
Amend 0003_S-501.pdf PDF
Amend 0003_11 20 00.pdf PDF
Amend 0003_13 34 19.pdf PDF
Amend 0003_28 31 63.pdf PDF
Amend 0003_A-301.pdf PDF
Amend 0003_22 07 19.pdf PDF
CRREL Climatic Cold Chambers - IFC Drawings.pdf PDF
Amendment 0002.pdf PDF
11 20 00 - Amend002_4-17-20.pdf PDF
Amendment 0001.pdf PDF
CRREL Climatic Chamber Pre-Bid Site Visit 16APR20.pdf PDF
Solicitation W912WJ20B0008 CREEL Climatic Cold Chambers Virtual Site Visit 2020-04-16-10-00-04.mp4 MP4 file
Solicitation W912WJ20B0008.pdf PDF
J A_Redacted.pdf PDF
Drawing.pdf PDF
Specifications.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F.F.

0"

PEMB ROOF

RIDGE

30' - 3"

123 C1

A-301

A1

A-302

T.O. CONCRETE

KNEE WALL

4' - 0"

2"

12"

C1

A-302

PEMB ROOF EAVE

25' - 0"

2"

12"

A4

A-602

TYP

C4

A-602

TYP

B4

A-602

TYP

C4

A-602

TYP

B4

A-602

TYP

A4

A-602

TYP 101A

7 7

T Y

P

B3

A-501

TYP

KEYED NOTES:

2 VENTILATION LOUVER; SEE MECHANICAL

1 MECHANICAL VENTILATOR; SEE MECHANICAL

3 4' CONCRETE KNEE WALL; SEE STRUCTURAL

4 WALL MOUNT EXTERIOR LIGHTING; SEE ELECTRICAL

5 EXHAUST HOOD

6 MECHANICAL UNIT CURB; ROOF CRICKET BUILT IN

7 CORNER TRIM

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-201

W E

S T

E L E

V A

T

IO

N

C O

L D

R E

G

IO

N S

R E

S E

A R

C H

A N

D E

N G

IN

E

E R

IN

G

L A

B O

R A

T O

R Y

C L

IM

A T

IC

C

O L D

C H

A M

B E

R

H A

N O

V E

R N

H N

E W

E N

G L A

N D

D

IS

T R

IC

T

V

IR

G

IN

IA

R O

A D

C

O N

C O

R D

M A

C O

L B

Y C

O M

P A

N Y

L L C

A

Y O

R K

S T

R E

E T

P

O R

T L A

N D

M E

C A

P

C A

P

B C

T

R T

M

/1

/2

W W

J B

W W

J -1

-D

-0

1/4" = 1'-0"A1

WEST ELEVATION

SCALE:

0 4' 8'

1/4" = 1' - 0"

4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

/2

A

M M

E N

D M

E N

T

/0

/2

C B A

PEMB ROOF

RIDGE

30' - 3"

D

A1

A-303

A1

A-304

T.O. CONCRETE

KNEE WALL

4' - 0"

PEMB ROOF EAVE

25' - 0"

B4

A-501

2 2

T Y

P

C2

A-501

TYP

C2

A-501

TYP

B3

A-501

TYP

C3

A-501

KEYED NOTES:

2 CORNER TRIM

1 MECHANICAL VENTILATOR; SEE MECHANICAL

3 4' CONCRETE KNEE WALL; SEE STRUCTURAL

4 WALL MOUNT EXTERIOR LIGHTING; SEE ELECTRICAL

5 EXHAUST HOOD; SEE MECHANICAL

6 PIPE VENT CAP; SEE MECHANICAL

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-202

N O

R T

H E

L E

V A

T

IO

N

C O

L D

R E

G

IO

N S

R E

S E

A R

C H

A N

D E

N G

IN

E

E R

IN

G

L A

B O

R A

T O

R Y

C L

IM

A T

IC

C

O L D

C H

A M

B E

R

H A

N O

V E

R N

H N

E W

E N

G L A

N D

D

IS

T R

IC

T

V

IR

G

IN

IA

R O

A D

C

O N

C O

R D

M A

C O

L B

Y C

O M

P A

N Y

L L C

A

Y O

R K

S T

R E

E T

P

O R

T L A

N D

M E

C A

P

C A

P

B C

T

R T

M

/1

/2

W W

J B

W W

J -1

-D

-0

1/4" = 1'-0"A1

NORTH ELEVATION

SCALE:

0 4' 8'

1/4" = 1' - 0"

4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

/2

A

M M

E N

D M

E N

T

/0

/2

PEMB ROOF

RIDGE

30' - 3"

1 2 3

C1

A-301

A1

A-302

T.O. CONCRETE

KNEE WALL

4' - 0"

C1

A-302

PEMB ROOF EAVE

25' - 0"

2"

12"

2"

12"

6 6

C4

A-602

TYP

B4

A-602

TYP

A4

A-602

TYP

C4

A-602

TYP

B4

A-602

TYP

A4

A-602

TYP

7 7

T Y

P

C2

A-501

TYP

C2

A-501

TYP

B3

A-501

TYP

KEYED NOTES:

2 INTAKE LOUVER; SEE MECHANICAL

1 MECHANICAL VENTILATOR; SEE MECHANICAL

3 4' CONCRETE KNEE WALL; SEE STRUCTURAL

4 WALL MOUNT EXTERIOR LIGHTING; SEE ELECTRICAL

5 EXHAUST HOOD

6 PIPE VENT CAP; SEE MECHANICAL

7 CORNER TRIM

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-203

E A

S T

E L E

V A

T

IO

N

C O

L D

R E

G

IO

N S

R E

S E

A R

C H

A N

D E

N G

IN

E

E R

IN

G

L A

B O

R A

T O

R Y

C L

IM

A T

IC

C

O L D

C H

A M

B E

R

H A

N O

V E

R N

H N

E W

E N

G L A

N D

D

IS

T R

IC

T

V

IR

G

IN

IA

R O

A D

C

O N

C O

R D

M A

C O

L B

Y C

O M

P A

N Y

L L C

A

Y O

R K

S T

R E

E T

P

O R

T L A

N D

M E

C A

P

C A

P

B C

T

R T

M

/1

/2

W W

J B

W W

J -1

-D

-0

1/4" = 1'-0"A1

EAST ELEVATION

SCALE:

0 4' 8'

1/4" = 1' - 0"

4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

/2

A

M M

E N

D M

E N

T

/0

/2

CBA

PEMB ROOF

RIDGE

30' - 3"

DA1

A-303

A1

A-304

T.O. CONCRETE

KNEE WALL

4' - 0"

PEMB ROOF EAVE

25' - 0"

B4

A-501

"1

B3

A-501

TYP

C3

A-501

KEYED NOTES:

2 PIPE VENT CAP; SEE MECHANICAL

1 MECHANICAL VENTILATOR; SEE MECHANICAL

3 4' CONCRETE KNEE WALL; SEE STRUCTURAL

4 WALL MOUNT EXTERIOR LIGHTING; SEE ELECTRICAL

5 CORNER TRIM

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-204

S O

U T

H E

L E

V A

T

IO

N

C O

L D

R E

G

IO

N S

R E

S E

A R

C H

A N

D E

N G

IN

E

E R

IN

G

L A

B O

R A

T O

R Y

C L

IM

A T

IC

C

O L D

C H

A M

B E

R

H A

N O

V E

R N

H N

E W

E N

G L A

N D

D

IS

T R

IC

T

V

IR

G

IN

IA

R O

A D

C

O N

C O

R D

M A

C O

L B

Y C

O M

P A

N Y

L L C

A

Y O

R K

S T

R E

E T

P

O R

T L A

N D

M E

C A

P

C A

P

B C

T

R T

M

/1

/2

W W

J B

W W

J -1

-D

-0

1/4" = 1'-0"A1

SOUTH ELEVATION

SCALE:

0 4' 8'

1/4" = 1' - 0"

4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

/2

A

M M

E N

D M

E N

T

/0

/2

COLD CHAMBER

F.F.

6"

C B A

PEMB ROOF

RIDGE

30' - 3"

D

T.O. COLD

CHAMBER ROOF

17' - 0"

A1

A-303

A1

A-304

T.O. CONCRETE

KNEE WALL

4' - 0"

PEMB ROOF EAVE

25' - 0"

T.O. MECHANICAL

ROOF

12' - 0"

B.O. FNDN

-5' - 0"

ABA RAMP, STAIR &

LANDING SUPPLIED

BY SHOWER &

OFFICE PACKAGE

HIGH BAY

LIGHTING

MECHANICAL

ROOM

8' CHAINLINK

FENCE WITH GATE

COLD

CHAMBER

VESTIBULE

101B

109B

EMERGENCY EYE

WASH STATION

RIDGE CAP

COLD CHAMBER

STAGING

ENCLOSURE

B4

A-501

D1

A-501

TYP

M

IN

C

U R

B

NOTES:

1. SEE SHEET A-001 FOR ARCHITECTURAL

LEGEND, ABBREVIATIONS, & GENERAL

NOTES.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-301

B U

IL

D

IN

G

S E

C T

IO

N

C O

L D

R E

G

IO

N S

R E

S E

A R

C H

A N

D E

N G

IN

E

E R

IN

G

L A

B O

R A

T O

R Y

C L

IM

A T

IC

C

O L D

C H

A M

B E

R

H A

N O

V E

R N

H N

E W

E N

G L A

N D

D

IS

T R

IC

T

V

IR

G

IN

IA

R O

A D

C

O N

C O

R D

M A

C O

L B

Y C

O M

P A

N Y

L L C

A

Y O

R K

S T

R E

E T

P

O R

T L A

N D

M E

C A

P

C A

P

B C

T

R T

M

/1

/2

W W

J B

W W

J -1

-D

-0

1/4" = 1'-0"C1

BUILDING SECTION

SCALE:

0 4' 8'

1/4" = 1' - 0"

4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

/2

A

M M

E N

D M

E N

T

/0

/2

S.E. ROOF LP

25' - 0"

COLD CHAMBER

F.F.

6"

CBA PEMB ROOF

RIDGE

30' - 3"

D

T.O. COLD

CHAMBER ROOF

17' - 0"

A1

A-303

A1

A-304

T.O. CONCRETE

KNEE WALL

4' - 0"

A-310 A3

A-310 A4

PEMB ROOF EAVE

25' - 0"

T.O. MECHANICAL

ROOF

12' - 0"

HIGH BAY

LIGHTING

ABA RAMP(1":12" SLOPE)

& LANDING PROVIDED BY

SHOWER & OFFICE

PACKAGE

HIGH BAY

LIGHTING

RIDGE CAP

R-30 MIN

RATED ROOF

R-19 MIN

RATED WALLS

STAGING

ENCLOSURE

COLD CHAMBER

IT

VESTIBULE

106 105101E

NOTES:

1. SEE SHEET A-001 FOR ARCHITECTURAL

LEGEND, ABBREVIATIONS, & GENERAL

NOTES.

F.F.

0"

S.E. ROOF LP

25' - 0"

COLD CHAMBER

F.F.

6"

CBA

PEMB ROOF

RIDGE

30' - 3"

D

T.O. COLD

CHAMBER ROOF

17' - 0"

T.O. CONCRETE

KNEE WALL

4' - 0"

PEMB ROOF EAVE

25' - 0"

T.O. MECHANICAL

ROOF

12' - 0"

HIGH BAY

LIGHTING

ABA RAMP(1":12" SLOPE)

& LANDING PROVIDED BY

SHOWER & OFFICE

PACKAGE

HIGH BAY

LIGHTING

MECHANICAL

ROOM

COLD

CHAMBER

COLD

CHAMBER

VESTIBULE

RIDGE CAP

R-30 MIN RATED

ROOF

R-19 MIN RATED

WALLS

STAGING

ENCLOSURE

MECHANICAL

VEHICULAR

RAMP AT

COLD

CHAMBER

B4

A-501

109B

106 105101E

C3

A-501

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-302

B U

IL

D

IN

G

S E

C T

IO

N

S

C O

L D

R E

G

IO

N S

R E

S E

A R

C H

A N

D E

N G

IN

E

E R

IN

G

L A

B O

R A

T O

R Y

C L

IM

A T

IC

C

O L D

C H

A M

B E

R

H A

N O

V E

R N

H N

E W

E N

G L A

N D

D

IS

T R

IC

T

V

IR

G

IN

IA

R O

A D

C

O N

C O

R D

M A

C O

L B

Y C

O M

P A

N Y

L L C

A

Y O

R K

S T

R E

E T

P

O R

T L A

N D

M E

C A

P

C A

P

B C

T

R T

M

/1

/2

W W

J B

W W

J -1

-D

-0

1/4" = 1'-0"A1

BUILDING SECTION SCALE:

0 4' 8'

1/4" = 1' - 0"

4' 8'

1/4" = 1'-0"C1

BUILDING SECTION

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

/2

A

M M

E N

D M

E N

T

/0

/2

COLD CHAMBER

F.F.

6"

PEMB ROOF

RIDGE

30' - 3"

T.O. COLD

CHAMBER ROOF

17' - 0"

C1

A-301

A1

A-302

T.O. CONCRETE

KNEE WALL

4' - 0"

C1

A-302

A-310 A2

PEMB ROOF EAVE

25' - 0"

T.O. MECHANICAL

ROOF

12' - 0"

B.O. FNDN

-5' - 0"

8' HIGH CHAINLINK

FENCE WITH GATE

EMERGENCY

EYEWASH STATION

OVERHEAD DOOR

HOUSING

OVERHEAD DOOR

HOUSING

COLD CHAMBER

MODULAR OFFICE

& SHOWER

BEYOND

MECHANICAL

ROOM

CRICKET AT

MECHANICAL

VENTILATOR

STAGING

ENCLOSURE

ERV PROVIDED WITH

SHOWER/OFFICE PACKAGE

REFRIGERATION

EQUIPMENT

PROVIDED WITH

COLD CHAMBER

PACKAGE

A1

A-501

TYP

B1

A-501

TYP

D1

A-501

TYP

HIGH BAY

LIGHTING

NOTES:

1. SEE SHEET A-001 FOR ARCHITECTURAL

LEGEND, ABBREVIATIONS, & GENERAL

NOTES.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-303

B U

IL

D

IN

G

S E

C T

IO

N

C O

L D

R E

G

IO

N S

R E

S E

A R

C H

A N

D E

N G

IN

E

E R

IN

G

L A

B O

R A

T O

R Y

C L

IM

A T

IC

C

O L D

C H

A M

B E

R

H A

N O

V E

R N

H N

E W

E N

G L A

N D

D

IS

T R

IC

T

V

IR

G

IN

IA

R O

A D

C

O N

C O

R D

M A

C O

L B

Y C

O M

P A

N Y

L L C

A

Y O

R K

S T

R E

E T

P

O R

T L A

N D

M E

C A

P

C A

P

B C

T

R T

M

/1

/2

W W

J B

W W

J -1

-D

-0

1/4" = 1'-0"A1

BUILDING SECTION

SCALE:

0 4' 8'

1/4" = 1' - 0"

4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

/2

A

M M

E N

D M

E N

T

/0

/2

T. O.

CONTROL/SUPPORT

14' - 0"

COLD CHAMBER

F.F.

6"

PEMB ROOF

RIDGE

30' - 3"

1 2

T.O. COLD

CHAMBER ROOF

17' - 0"

C1

A-301

A1

A-302

T.O. CONCRETE

KNEE WALL

4' - 0"

C1

A-302

PEMB ROOF EAVE

25' - 0"

B.O. FNDN

-5' - 0"

8' HIGH CHAINLINK

FENCE WITH GATE

EMERGENCY

EYEWASH

STATION

PRE ENGINEERED

STRUCTURE

COLD CHAMBER

COLD CHAMBER

VESTIBULE

MECHANICAL

VENTILATOR

CURB WITH

BUILT IN

CRICKET

PREFAB OFFICE

STAGING

ENCLOSURE

A-501 B2

A-501 B4

COLD CHAMBER

VESTIBULE

A1

A-501

TYP

B1

A-501

TYP

D1

A-501

TYP

VEHICULAR RAMP

PROVIDE W/ COLD

CHAMBER PACKAGE.

1 1/2" : 12"

1 1/2" / 12"

HIGH BAY

LIGHTING

2R @ 4" = 0'-8"

NOTES:

1. SEE SHEET A-001 FOR ARCHITECTURAL

LEGEND, ABBREVIATIONS, & GENERAL

NOTES.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-304

B U

IL

D

IN

G

S E

C T

IO

N

C O

L D

R E

G

IO

N S

R E

S E

A R

C H

A N

D E

N G

IN

E

E R

IN

G

L A

B O

R A

T O

R Y

C L

IM

A T

IC

C

O L D

C H

A M

B E

R

H A

N O

V E

R N

H N

E W

E N

G L A

N D

D

IS

T R

IC

T

V

IR

G

IN

IA

R O

A D

C

O N

C O

R D

M A

C O

L B

Y C

O M

P A

N Y

L L C

A

Y O

R K

S T

R E

E T

P

O R

T L A

N D

M E

C A

P

C A

P

B C

T

R T

M

/1

/2

W W

J B

W W

J -1

-D

-0

1/4" = 1'-0"A1

BUILDING SECTION

SCALE:

0 4' 8'

1/4" = 1' - 0"

4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

/2

A

M M

E N

D M

E N

T

/0

/2

A

PEMB ROOF

RIDGE

30' - 3"

T.O. COLD

CHAMBER ROOF

17' - 0"

T.O. CONCRETE

KNEE WALL

4' - 0"

A-501 A4

PEMB ROOF EAVE

25' - 0"

T.O. MECHANICAL

ROOF

12' - 0"

B.O. FNDN

-5' - 0"

A3

A-501

WALL GIRT

CORRUGATED

METAL PANEL

RAKE

FLASHING

STANDING

SEAM METAL

ROOF

F.F.

0"

PEMB ROOF

RIDGE

30' - 3"

D

T.O. CONCRETE

KNEE WALL

4' - 0"

METAL PANEL

PEMB ROOF EAVE

25' - 0"

T.O. MECHANICAL

ROOF

12' - 0"

B.O. FNDN

-5' - 0"

PEMB STRUCTURE

MINERAL WOOL

INSULATION; FULL

CAVITY

MINERAL WOOL

INSULATION; 3 5/8"

RAKE FLASHING

STANDING SEAM

METAL ROOF

POLYISO RIGID

INSULATION

BOARD; 3"

LIGHTING PANEL

BOARD

F.F.

0"

COLD CHAMBER

F.F.

6"

T.O. COLD

CHAMBER ROOF

17' - 0"

PEMB ROOF EAVE

25' - 0"

T.O. MECHANICAL

ROOF

12' - 0"

B.O. FNDN

-5' - 0"

EAVE TRIM

INTERIOR MOUNTED

OVERHEAD DOOR

HOUSING

A2

A-501

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-310

W A

L L S

E C

T

IO

N S

C O

L D

R E

G

IO

N S

R E

S E

A R

C H

A N

D E

N G

IN

E

E R

IN

G

L A

B O

R A

T O

R Y

C L

IM

A T

IC

C

O L D

C H

A M

B E

R

H A

N O

V E

R N

H N

E W

E N

G L A

N D

D

IS

T R

IC

T

V

IR

G

IN

IA

R O

A D

C

O N

C O

R D

M A

C O

L B

Y C

O M

P A

N Y

L L C

A

Y O

R K

S T

R E

E T

P

O R

T L A

N D

M E

C A

P

C A

P

B C

T

R T

M

/1

/2

W W

J B

W W

J -1

-D

-0

1/2" = 1'-0"A3

WALL SECTION

1/2" = 1'-0"A4

WALL SECTION

SCALE:

0 2' 4'

1/2" = 1' - 0"

2' 4'

1/2" = 1'-0"A2

WALL SECTION

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

/2

A

M M

E N

D M

E N

T

/2

/2

A

M M

E N

D M

E N

T

/0

/2

2 2

Sheets
A-201 - WEST ELEVATION
A-202 - NORTH ELEVATION
A-203 - EAST ELEVATION
A-204 - SOUTH ELEVATION
A-301 - BUILDING SECTION
A-302 - BUILDING SECTIONS
A-303 - BUILDING SECTION
A-304 - BUILDING SECTION
A-310 - WALL SECTIONS

File details come from the government source that posted it. Updated .