Amend 0003_CD-101.pdf
PDF 254 KB Posted
- Solicitation number
- W912WJ20B0008
About this file
This document includes an amendment to plans for site demolition work and the related federal contract solicitation. The amendment provides details on sawcutting and removing an existing 6-inch thick concrete slab covering 13,400 square feet, demolishing 335 square feet and 140 square feet of existing asphalt paving, and removing grass and topsoil for a 1,450 square foot asphalt entrance. It also specifies demolishing an existing metal-sided lean-to structure and wood-framed shed by others prior to contractor mobilization, and installing inlet protection prior to demolition work. Solicitation W912WJ20B0008 from the Department of the Army Corps of Engineers Engineering District New England is for the construction of a new Climatic Chamber Building at the Cold Regions Research and Engineering Laboratory in Hanover, New Hampshire.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SAWCUT AND REMOVE
EXISTING ±6" THICK
CONCRETE SLAB, ±13,400 SF
EXISTING CHAIN LINK FENCE TO BE
DEMOLISHED BY OTHERS PRIOR TO
CONTRACTOR MOBILIZATION ON
SITE.
SAWCUT AND REMOVE EXISTING
ASPHALT PAVING, ±335 SF
SAWCUT AND REMOVE EXISTING
ASPHALT PAVING, ±140 SF
REMOVE GRASS AND TOPSOIL FOR
ASPHALT ENTRANCE, ±1,450 SF
LEAN-TO AND SHED TO BE
DEMOLISHED BY OTHERS
PRIOR TO CONTRACTOR
MOBILIZATION ON SITE.
INSTALL INLET PROTECTION PRIOR TO
DEMOLITION
A1 C-502
LIMIT OF CONCRETE SAWCUT
N:44,7370.51 E:823,691.92
LIMIT OF CONCRETE SAWCUT
N:447,356.87 E:823,726.16
LIMIT OF CONCRETE SAWCUT
N:447,316.14 E:823,709.93
LIMIT OF CONCRETE SAWCUT
N:447,285.22 E:823,787.54
D
2 3
C
4 5
A
B
M A
R K
D E
S C
R I P
T I O
N
SHEET ID
D A
T E
US Army Corps of Engineers ®
I S
S U
E
D
A T
E
S O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
C T
N
O
F I L
E
N
U M
B E
R
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
F I L
E
N
A M
E
U S
A
R M
Y
C
O R
P
F
E
N G
I N
E E
R S
C O
L D
E G
I O
S
E A
R C
H
A
G
I N
E E
R I N
G
L A
B O
R A
T O
R Y
C L I M
A T
E
C
O L
H A
M B
E R
S
H
A N
O V
E R
N
H
N E
W
E
N G
L A
I S
T R
I C
T
V
E R
G I N
I
A
D
C
O N
C O
M
C O
L B
Y
C
O M
P A
N Y
L L C
Y
R
K
S
T R
E E
T
P
O R
T L A
M
A N
S I
D
W
W J
B
W
W J
D
I S
S U
F
N
S T
R U
C T
I O
N
0 20' 40'
Scale: 1" = 20'-0"
SCALE 1"=20'-0"
SITE DEMOLITION PLANA1
CD-101
S I T
E
D
E M
O L I T
I O
N
P
L A
N
Z R
J
Z R
J
L D
A
C B
D
W G
KEYED NOTES:
DEMOLISH AND DISPOSE OF HAZARDOUS MATERIALS SHED
SHED MEASURES 11'-8" EXTERIOR (10'-8" INTERIOR) BY 8'-8"
EXTERIOR (7'-8" INTERIOR) X 8'-9" TALL (INTERIOR) AND
CONSISTS OF FOLLOWING:
· CONCRETE FLOOR
· PAINTED GYP WALLS
· METAL DOOR (6'-8", 34" WIDTH)
· VINYL COVE BASE
· SHELVING ON 2X4S
· TWO LIGHT FIXTURES (CLG MOUNTED) -
· ELECTRIC UNIT HEATER
· ELECTRICAL PANEL
· TWO ROOF VENTS
· ONE WINDOW (3'X4')
DEMOLISH AND DISPOSE OF WOOD FRAMED SHED
SHED MEASURES 15'X11'X7' TALL (INTERIOR DIMENSIONS) AND
CONSISTS OF THE FOLLOWING:
· VINYL FLOORING
· PLYWOOD SHEATHING
· WINDOW
· FOUR LIGHT FIXTURES
· WIREWAYS WITH OUTLETS THROUGHOUT
· ROOF SHINGLES
· ELECTRICAL PANEL (OUT OF SERVICE)
PROTECT T.C.E. EXTRACTION WELL BUILDINGS, WELLS, WATER
LINES, AND ELECTRICAL LINES DURING CONSTRUCTION.
NOTES:
1. SEE SHEET C-101 FOR HORIZONTAL AND VERTICAL BENCHMARKS.
2. HAZARDOUS MATERIAL SCREENING OF THE TWO SHEDS TO BE
DEMOLISHED FOUND THE LIGHTING FIXTURES IN BOTH SHEDS TO
CONTAIN MERCURY. NO OTHER HAZARDOUS MATERIALS (ACM,
LEAD, PCBs) WERE IDENTIFIED.