About this file

This document contains plumbing details and specifications for the construction of a new climatic chamber building at the Cold Regions Research and Engineering Laboratory in Hanover, New Hampshire. The project involves domestic water entrance details, emergency shower details, pipe hanger attachment details, an electronic trap primer detail, and electric water heater details. Plumbing specifications include underground sanitary insulation and electric heat trace to prevent freezing. Mechanical drawings show vent piping isometrics for both the north and south sides of the building. Solicitation W912WJ20B0008 was issued by the Department of the Army Corps of Engineers New England District for the climatic chamber building construction. The solicitation deadline is not specified in the file.

View the file

Other files

File Type Posted
Bid Abstract.pdf PDF
Bid Summary_W912WJ20B0008.pdf PDF
Amendment 0006.pdf PDF
Amend 0005_Architectural Drawing Revisions.pdf PDF
Amend 0005_13 34 19.pdf PDF
Amendment 0005.pdf PDF
Amend 0004_11 01 00.pdf PDF
Amendment 0004.pdf PDF
Amend 0004_13 34 19.pdf PDF
Amend 0003_A-310.pdf PDF
Amend 0003_03 30 00.pdf PDF
Amend 0003_S-301.pdf PDF
Amend 0003_CD-101.pdf PDF
Amend 0003_C-503.pdf PDF
Amend 0003_A-601.pdf PDF
Amendment 0003.pdf PDF
Amend 0003_S-501.pdf PDF
Amend 0003_11 20 00.pdf PDF
Amend 0003_13 34 19.pdf PDF
Amend 0003_28 31 63.pdf PDF
Amend 0003_A-301.pdf PDF
Amend 0003_22 07 19.pdf PDF
CRREL Climatic Cold Chambers - IFC Drawings.pdf PDF
Amendment 0002.pdf PDF
11 20 00 - Amend002_4-17-20.pdf PDF
Amendment 0001.pdf PDF
CRREL Climatic Chamber Pre-Bid Site Visit 16APR20.pdf PDF
Solicitation W912WJ20B0008 CREEL Climatic Cold Chambers Virtual Site Visit 2020-04-16-10-00-04.mp4 MP4 file
Solicitation W912WJ20B0008.pdf PDF
J A_Redacted.pdf PDF
Drawing.pdf PDF
Specifications.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INDIRECT WASTE WITH AIR GAP

2" DCW ENTRANCE,

SEE CIVIL DRAWINGS

FOR CONTINUATION

HOPPER

DRAIN

HD-1

WATER

METER

WM-1

STRAINER

REMOTE

WATER METER

READER

HB-1

BFP-1

1 1/2"

1 1/2"

GRADE

FLOOR

LINE-SIZE PRV,

SET TO 80 PSIG

1 1/2"

TO

MB-1

TO

TP-1

TO

ES-1

1 1/2" 1 1/4"

EHT

ON PIPING THROUGH

AND ABOVE MECHANICAL

ROOM CEILING

FINISHED FLOOR

EYE WASH HEAD

ASSEMBLY

PUSH PLATE

PULL ROD

SHOWER

HEAD

SHROUD

1 1/4" DRAIN CONNECTION

WITH HEAT TRACE, ROUTE

TIGHT TO WALL TO HD-1

FD

JUNCTION BOX WITH

INDICATOR LIGHTS

PARTITION

INSULATION AND

ELECTRIC HEAT TRACE

ON ENTIRE ASSEMBLY

ELECTRIC HEAT

TRACE IN PIPE TO FD

TEE FOR HEAT TRACE

AND TRAP PRIMER

SIGN1 1/4" TD CONNECTION

WITH HEAT TRACE

INSULATION BOARD

TYP. SEE DETAIL.

HEAVY-DUTY

CLEVIS HANGER, TYP

LOCKING NUT, TYP

SUPPORT NUT, TYP

INSULATION, TYP

PIPE, TYP

PIPE COVERING

PROTECTIVE

SADDLE

CLEVIS HANGER

(FOR PIPES 2-1/2" & SMALLER)

ADJUSTABLE HANGER W/ROLLER

(FOR PIPES 3" THRU 6")

GALVANIZED

SHIELD

3/8" FLEXIBLE METAL

CONDUIT FITTING

COPPER

1/2" PLASTIC

BALL VALVE

PLASTIC MANIFOLD

TO SERVE

MULTIPLE DRAINS

PEX

16 GAUGE POWDER

EPOXY COATED (WHITE)

STEEL CABINET

COMPRESSION PLASTIC

CONNECTORS TO RECEIVE

1/2" PIPING. SLEEVE PIPING

IN 1" SCH 80 PVC CONDUIT

LONG RADIUS ELBOWS TO

PROTECT PIPING THRU SLAB.

VACUUM BREAKER

ELECTRONIC

SOLENOID VALVE

CONTROL UNIT WITH 24

HOUR TIMER WITH RELAY

WHA-C

1 1/4" DCW

EW-1

1 1/4" TW

RELIEF PIPE, FULL

VALVE OUTLET

SIZE OR LARGER

ANTI-SCALD

PURGE OUTLET

TYPE L COPPER PIPE AT SIZE

RECOMMENDED BY MFR, BUT

NO LESS THAN 1 1/4", RUN

TIGHT TO WALL TO HOPPER

DRAIN WITH AIR GAP

3/4"

FLOOR

ANCHOR LEGS TO

FLOOR PER MFR

RECOMMENDATIONS

SS SHIMS TO ISOLATE

FEET FROM FLOOR SLAB

NOTE:

INSTALL WITH SERVICE CLEARANCES

RECOMMENDED BY MANUFACTURER.

1 1/4"

FD-2

MB-1

HD-1

3" VTR, 5 FT

FROM RIDGE LINE

CEILING

PENETRATION

2"

2"

3"

FIELD CONNECTION

TO PREFAB SHOWER

FD-2

2"

3"

3" VTR, 5 FT

FROM RIDGE LINE

3"

EXTRUDED POLYSTYRENE

FOAM BOARD INSULATION

FILL, TYP

EHT TO PROTECT PIPING ABOVE SLAB,

AIR GAPS/BREAKS AT FLOOR DRAINS,

AND BELOW SLAB TO AT LEAST 10 FT

FROM FLOOR PENETRATION

FLOOR SLAB

FD, FCO, OR OTHER PIPE

PENETRATION THRU SLAB

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

12345

D

C

B

A

P-501

P L U

M B

IN

G

D E

T A

IL

S

C O

L D

R E

G

IO

N S

R E

S E

A R

C H

E

N G

IN

E

E R

IN

G

L A

B O

R A

T O

R Y

C L

IM

A T

IC

C

O L D

C H

A M

B E

R S

H

A N

O V

E R

, N H

N E

W E

N G

L A

N D

D

IS

T R

IC

T

V

IR

G

IN

IA

R O

A D

, C O

N C

O R

D M

A

C O

L B

Y C

O M

P A

N Y

, L L C

A

Y O

R K

S T

R E

E T

, P O

R T

L A

N D

M E

D H

B

C S

S

B C

T

P W

B

/1

/2

W W

J B

W W

J -1

-D

-0

P -5

NTS A4

DOMESTIC WATER ENTRANCE DETAIL

NTS C4

EMERGENCY SHOWER DETAIL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

/2

A

M M

E N

D M

E N

T

/2

/2

NTS A2

PIPE HANGER ATTACHMENT DETAIL

NTS A1

ELECTRONIC TRAP PRIMER DETAIL

NTS B1

ELECTRIC WATER HEATER DETAIL

NTS B2

VENT ISOMETRIC -SOUTH

NTS D2

VENT ISOMETRIC -NORTH

NTS D1

UNDERSLAB SAN INSULATION AND EHT

NSED

E CI

L

No.7551

OF ET

A T

S

MA

IN

E

NL A OI SS

E

F O

R P

ENG

IN

E E R

DAVID H.

BROWN

04/29/2

Sheets
P-501 - PLUMBING DETAILS

File details come from the government source that posted it. Updated .