W912QR26BA021_Plans-0003.pdf

PDF 6 MB Posted

Attached to
Renovation/Repair of Bldg 27 at DSCC, OH
Solicitation number
W912QR26BA021
Issued by

About this file

This file contains architectural, mechanical, electrical, plumbing, and fire protection construction documents for a renovation project at DSCC DLA Repair Building 27 located in Louisville, Kentucky. The project, identified as solicitation W912QR26BA021 with contract number 25-25126-00, is a phased remodeling and repair effort for Building 27 at the Defense Supply Center Columbus facility.

The scope includes comprehensive demolition and renovation across multiple building areas, with work divided into distinct zones (Areas 11N, 12N, 13N, 11S, 12S, 13S, and Mezzanine). Key architectural work includes EIFS (Exterior Insulating Finish System) installation over masonry and concrete, new storefront doors and windows, interior locker room renovations with benches and countertops, and updated interior finishes. Mechanical systems scope encompasses variable air volume terminal units, air handling units with DDC controls, chilled water and hot water systems, exhaust fans, unit heaters, and complete HVAC piping and ductwork installation with BACnet integration. Electrical work requires new 750 kVA and 500 kVA pad-mounted transformers with concrete pads and grounding, new primary and secondary conductors, branch circuiting for power and lighting, receptacles, switches, and emergency systems. Plumbing work includes domestic water and hot water system modifications, fixtures in locker rooms and restrooms, and integrated equipment connections. Fire protection work requires coordination with existing Simplex 4100U system, new addressable sprinkler heads and strobes at appropriate candela ratings, and fire alarm devices throughout the renovated spaces. The construction documents are issued at 100% Certified Final design dated March 13, 2026, with Amendment 0003 dated September 3, 2026, indicating active procurement and construction phase preparation.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T R

A C

T N

O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

A u to d e s k D o c s /2

-2

-0

D

L A

D S

C C

B ld g

R

E P

F

R e m o d /2

-2

-0

D

L A

D S

C C

B ld g R

E P

F R e m o d A

R .r v t

/8

/2

:4

:1

P M

GI001

S H

E E

T I N

D E

X

C O

L U

M B

U S

O

H

IO

L O

U

IS

V

IL

L E

K

Y E

.E

E .E

A .B

E .B

M a rc h

C E

R T

IF

IE

D

F

IN

A L

D S

C C

D L A

R E

P A

IR

B

U

IL

D

IN

G

-2

-0

.ARCHITECTURAL.

A-001 GENERAL NOTES, ARCHITECTURAL SYMBOLS & ABBREVIATIONS

AD101 DEMOLITION PLAN OVERALL

AD102 DEMOLITION PLAN - AREA 11N

AD103 DEMOLITION PLAN - AREA 12N

AD104 DEMOLITION PLAN - AREA 13N

AD105 DEMOLITION PLAN - AREA 11S

AD106 DEMOLITION PLAN - AREA 12S

AD107 DEMOLITION PLAN - AREA 13S

AD108 DEMOLITION PLAN - MEZZANINE AREA

AD201 EXTERIOR DEMO ELEVATIONS

A-101 FLOOR PLAN OVERALL

A-102 FLOOR PLAN - AREA 11N

A-103 FLOOR PLAN - AREA 12N

A-104 FLOOR PLAN - AREA 13N

A-105 FLOOR PLAN - AREA 11S

A-106 FLOOR PLAN - AREA 12S

A-107 FLOOR PLAN - AREA 13S

A-108 OVERALL - REFLECTED CEILING PLAN

A-201 EXTERIOR ELEVATIONS

A-401 PARTITION TYPES

A-402 DOOR & WINDOWS FRAME TYPE & SCHEDULE

A-501 DOOR AND FRAME DETAILS

A-502 EXTERIOR DETAILS

.GENERAL.

G-001 COVER SHEET

GI001 SHEET INDEX

GC001 GENERAL PHASING NOTES

GC002 FLOOR PLAN OVERALL PHASING

.STRUCTURAL.

S-001 GENERAL STRUCTURAL NOTES

S-002 GENERAL STRUCTURAL NOTES & SPECIAL INSPECTIONS

S-003 GENERAL STRUCTURAL NOTES, SYMBOLS & ABBREVIATIONS

S-100 STRUCTURAL PLAN - AREA 11N

S-101 STRUCTURAL PLAN - AREA 11S

S-102 STRUCTURAL PLAN - AREA 12N

S-103 STRUCTURAL PLAN - AREA 12S

S-104 STRUCTURAL PLAN - AREA 13N

S-105 STRUCTURAL PLAN - AREA 13S

S-500 STRUCTURAL DETAILS

S-501 STRUCTURAL DETAILS

.MECHANICAL.

M-001 GENERAL INFORMATION - HVAC

MD101 AREA 11-N HVAC DEMOLITION PLAN

MD102 AREA 12-N HVAC DEMOLITION PLAN

MD103 AREA 13-N HVAC DEMOLITION PLAN

MD104 AREA 11-S HVAC DEMOLITION PLAN

MD105 AREA 12-S HVAC DEMOLITION PLAN

MD106 AREA 13-S HVAC DEMOLITION PLAN

MD401 MEZZANINE ENLARGED HVAC DEMOLITION PLAN

M-002 FIRST FLOOR HVAC ZONING PLAN

MH101 AREA 11-N HVAC DUCTWORK PLAN

MH102 AREA 12-N HVAC DUCTWORK PLAN

MH103 AREA 13-N HVAC DUCTWORK PLAN

MH104 AREA 11-S HVAC DUCTWORK PLAN

MH105 AREA 12-S HVAC DUCTWORK PLAN

MH106 AREA 13-S HVAC DUCTWORK PLAN

MH107 BOILER ROOM HVAC DUCTWORK PLAN

MH501 HVAC DETAILS

MH701 HVAC SCHEDULES

MP101 AREA 11-N HVAC PIPING PLAN

MP102 AREA 12-N HVAC PIPING PLAN

MP103 AREA 13-N HVAC PIPING PLAN

MP104 AREA 11-S HVAC PIPING PLAN

MP105 AREA 12-S HVAC PIPING PLAN

MP106 AREA 13-S HVAC PIPING PLAN

MP501 HVAC DETAILS

MP601 HVAC PIPING SCHEMATICS

MP701 HVAC SCHEDULES

M-301 MECHANICAL ROOM SECTION AND ISOMETRIC VIEWS

M-401 MECHANICAL ROOM ENLARGED PLAN

MI801 HVAC SEQUENCE OF OPERATIONS / CONTROLS

MI802 HVAC SEQUENCE OF OPERATIONS / CONTROLS

MI803 HVAC SEQUENCE OF OPERATIONS / CONTROLS

MI804 HVAC SEQUENCE OF OPERATIONS / CONTROLS

.PLUMBING.

P-001 GENERAL INFORMATION - PLUMBING

PD101 LEVEL 01 - AREA 11-N PLUMBING DEMOLITION PLAN

PD102 LEVEL 01 - AREA 12-N PLUMBING DEMOLITION PLAN

PL101 AREA 11-N - PLUMBING PLAN

PL102 AREA 12-N - PLUMBING PLAN

PL104 AREA 11-S - PLUMBING PLAN

PL105 AREA 12-S - PLUMBING PLAN

P-401 ENLARGED PLUMBING PLANS

P-501 PLUMBING DETAILS/SCHEDULES

.FIRE PROTECTION.

FP001 NOTES & LEGENDS - FIRE PROTECTION

FA001 FIRE ALARM LEGEND, NOTES, DIAGRAMS AND ABBREVIATIONS

FP100 FIRE PROTECTION SITE PLAN

FS101 LEVEL 01 - LIFE SAFETY PLAN

FS102 LEVEL 01 - BUILDING CODE ANALYSIS

FS103 LEVEL 01 - BUILDING CODE ANALYSIS

FD101 LEVEL 01 - FIRE PROTECTION DEMOLITION OVERALL FLOOR PLAN

FD201 LEVEL 01 - AREA 12 - FIRE ALARM DEMOLITION PLAN

FH101 LEVEL 01 - FIRE PROTECTION OVERALL HAZARD PLAN

FP101 AREA 12-N FIRE SPRINKLER PLAN

FP102 AREA 12-S FIRE SPRINKLER PLAN

FP103 AREA 13-S FIRE SPRINKLER PLAN

FP104 AREA 10-N FIRE SPRINKLER PLAN

FA201 LEVEL 01 - AREA 12 - FIRE ALARM PLAN

FP501 FIRE PROTECTION DETAILS

FA501 FIRE ALARM DETAILS

FP601 MECHANICAL ROOM 1203 HYDRAULIC CALCS

FP602 MECHANICAL ROOM 1203 HYDRAULIC CALCS

FP603 MOST REMOTE AREA HYDRAULIC CALCS

FP604 MOST REMOTE AREA HYDRAULIC CALCS

FP605 BOILER ROOM HYDRAULIC CALCS

FP606 BOILER ROOM HYDRAULIC CALCS

FP607 BOILER ROOM HYDRAULIC CALCS

.ELECTRICAL.

E-001 GENERAL INFORMATION - ELECTRICAL

ES101 ELECTRICAL SITE PLAN

ED101 AREA 11-N - ELECTRICAL DEMOLITION PLAN

ED102 AREA 12-N - ELECTRICAL DEMOLITION PLAN

ED103 AREA 13-N - ELECTRICAL DEMOLITION PLAN

ED104 AREA 11-S - ELECTRICAL DEMOLITION PLAN

ED105 AREA 12-S - ELECTRICAL DEMOLITION PLAN

ED106 AREA 13-S - ELECTRICAL DEMOLITION PLAN

ED107 AREA 7-N - ELECTRICAL DEMOLITION PLAN

ED401 ELECTRICAL ENLARGED DEMOLITION PLAN - MEZZANINE

EL101 AREA 11-N - ELECTRICAL LIGHTING PLAN

EL102 AREA 12-N - ELECTRICAL LIGHTING PLAN

EL103 AREA 13-N - ELECTRICAL LIGHTING PLAN

EL104 AREA 11-S - ELECTRICAL LIGHTING PLAN

EL105 AREA 12-S - ELECTRICAL LIGHTING PLAN

EL106 AREA 13-S - ELECTRICAL LIGHTING PLAN

EP201 AREA 11-N - ELECTRICAL POWER SYSTEMS PLAN

EP202 AREA 12-N - ELECTRICAL POWER SYSTEMS PLAN

EP203 AREA 13-N - ELECTRICAL POWER SYSTEMS PLAN

EP204 AREA 11-S - ELECTRICAL POWER SYSTEMS PLAN

EP205 AREA 12-S - ELECTRICAL POWER SYSTEMS PLAN

EP206 AREA 13-S - ELECTRICAL POWER SYSTEMS PLAN

EP207 BOILER ROOM - ELECTRICAL POWER SYSTEMS PLAN

EP208 AREA 7-N - ELECTRICAL POWER SYSTEMS PLAN

E-401 ELECTRICAL ENLARGED PLANS

E-501 ELECTRICAL DETAILS

E-502 ELECTRICAL DETAILS

E-503 ELECTRICAL DETAILS

E-601 ELECTRICAL SINGLE-LINE DIAGRAM - DEMOLITION

E-602 ELECTRICAL SINGLE-LINE DIAGRAM - NEW WORK

E-603 ELECTRICAL PANELBOARD SCHEDULE

HAZARD MITIGATION

HM101 ASBESTOS SAMPLE LOCATION

HM102 LEAD PAINT SAMPLE LOCATION

.INTERIORS.

I-111 INTERIOR DETAILS

I-112 INTERIOR SIGNANGE DETAILS

I-101 ENLARGED LOCKER ROOM PLANS

I-102 ENLARGED LOCKER ROOM FINISH PLANS

I-103 ENLARGED LOCKER ROOM FURNITURE PLANS

I-201 WOMENS LOCKER ROOM INTERIOR ELEVATIONS

I-202 MENS INTERIOR ELEVATIONS

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/3

/2

9/3/2026

W

2Q R

BA

1_

Pl an s-

FFE

0' - 0"

TOP OF WALL

14' - 6"

E1

A-502

EA

FFE

0' - 0"

TOP OF WALL

14' - 6"

B

C

FFE

0' - 0"

TOP OF WALL

14' - 6"

B BBBBBBC C

SHEET NOTES#

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T R

A C

T N

O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

A u to d e s k D o c s /2

-2

-0

D

L A

D S

C C

B ld g

R

E m o d /2

-2

-0

D

L A

D S

C C

B ld g R

E P

F R e m o d A

R .r v t

/8

/2

:4

:1

P M

A-201

E X

T E

R

IO

R E

L E

V A

T

IO

N S

C O

L U

M B

U S

O

H

IO

L O

U

IS

V

IL

L E

K

Y E

.E

E .E

A .B

E .B

M a rc h

C E

R T

IF

IE

D

F

IN

A L

D S

C C

D L A

R E

P A

IR

B

U

IL

D

IN

G

-2

-0

1/16" = 1'-0"K1

BUILDING ELEVATION NORTH

1/16" = 1'-0"F1

BUILDING ELEVATION EAST

1/16" = 1'-0"A1

BUILDING ELEVATION SOUTH

1 NEW DOOR AS PER OPENING SCHEDULE.

2 NEW WINDOW AS PER OPENING SCHEDULE. RE: SHEET A-402

3 NEW EXTERIOR INSULATING FOAM SYSTEM (EIFS) AS PER SPECIFICATIONS OVER

EXISTING MASONRY WALL AND EXTERIOR FACE OF CONCRETE STRUCTURE.

4 EXISTING WINDOW TO REMAIN IN PLACE .

5 EXISTING EXTERIOR DOOR TO REMAIN IN PLACE.

6 NEW STOREFRONT SYSTEM AS PER OPENING SCHEDULE. RE: SHEET A-402

7 EIFS CONTROL JOINTS TO FOLLOW EXISTING CONCRETE COLUMN / BEAM LINES.

TYPICAL.EIFS OVER CONCRETE TO BE COLOR 1 - EIFS OVER BRICK TO BE COLOR 2.

8 THE EXTENT OF THE NEW EIFS ON THIS BUILDING IS LIMITED TO THE NORTH, EAST

AND SOUTH ELEVATIONS AROUND THE AREA BEING REMODELED AS SHOWN IN THE

CONSTRUCTION DOCUMENTS.

112 24

4 442

3 33

5 6

6 644 45 5

333 33

7 7 77

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/3

/2

9/3/2026

W

2Q R

BA

1_

Pl an s-

F FG

FLUSH PANEL FULL LIGHT

0"

6" 6"

SCHEDULE

SEE

S C

H E

D U

L E

S E

E

G

FULL LIGHT

SCHEDULE

SEE

S C

H E

D U

L E

S E

E

6" 6"

2"

2"

SCHEDULE

SEE

S E

E S

C H

E D

U L

E

2"

2"

SCHEDULE

SEE

S E

E S

C H

E D

U L

E

DG DUAL LITE GLASS

F FLUSH PANEL

FG FULL LITE GLASS

FL FULL LOUVERED

G HALF LITE GLASS

GL HALF LITE GLASS & LOUVERED

L LOUVERED (BOTTOM)

LL LOUVERED (TOP & BOTTOM)

N NARROW LITE GLASS

NL NARROW LITE GLASS & LOUVERED

TL LOUVERED (TOP)

V VISION LITE GLASS (10" SQUARE)

VL VISION LITE GLASS & LOUVERED

DOOR PANEL TYPE DESCRIPTIONS DOOR AND FRAME SCHEDULE

GENERAL NOTES

A. ALL HOLLOW METAL FRAMES SET IN MASONRY WALLS SHALL

BE FILLED WITH GROUT.

B. ALL HOLLOW METAL FRAMES SET IN METAL STUD WALLS

SHALL BE FILLED WITH MINERAL WOOL BLANKET INSULATION.

C. ALL EXTERIOR FRAMES SHALL BE INSTALLED WITH 1/4" SHIM

AND SEALANT AROUND PERIMETER OF FRAME.

D. GLASS TYPES FOR DOORS ARE INDICATED IN THE DOOR

GLAZING COLUMN OF THE DOOR AND FRAME SCHEDULE.

GLASS TYPES FOR FRAMES ARE INDICATED ON THE FRAME

ELEVATIONS.

E. FOR COILING DOORS, GRILLES AND SECTIONAL DOORS, WIDTH

AND HEIGHT DIMENSIONS SHOWN IN DOOR AND FRAME

SCHEDULE REPRESENT FINISHED OPENING SIZE.

CONTRACTOR TO COORDINATE EXACT SIZE OF DOOR WITH

MANUFACTURER.

F. SEE SPECIFICATIONS HARDWARE SECTION FOR HARDWARE

SETS NOTED IN DOOR AND FRAME SCHEDULE.

G. SG: SPECIALTY GLASS AT FRAME TYPES "A" AND "E" ARE TO BE

CLEAR TEMPERED INSULATING SAFETY GLASS WITH AN ACID

ETCHED FINISH.

A B

5' - 0"

2" 2' - 3"

2" 2' - 3"

2"

CIG CIG

C D E

SG SG

2" 3' - 9" 2" 3' - 9" 2"

8' - 0"

10' - 0"

2" 1' - 8" 2" 6' - 0" 2" 1' - 8" 2"

CIG

CIG

CTIG CTIG

CIGCIG

CIG CIG

10' - 0"

2" 3' - 1 1/2"

2"

3' - 2 1/2"

2"

3' - 0" 2"

CTG CTG

CTG CTGCTG

SG SG

4' - 1"

3' - 9"0"3' - 11"2"0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T R

A C

T N

O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

A u to d e s k D o c s /2

-2

-0

D

L A

D S

C C

B ld g

R

E m o d /2

-2

-0

D

L A

D S

C C

B ld g R

E P

F R e m o d A

R .r v t

/8

/2

:4

:1

P M

A-402

D O

O R

W

IN

D

O W

S F

R A

M E

T Y

P E

S

C H

E D

U L E

C O

L U

M B

U S

O

H

IO

L O

U

IS

V

IL

L E

K

Y E

.E

E .E

A .B

E .B

M a rc h

C E

R T

IF

IE

D

F

IN

A L

D S

C C

D L A

R E

P A

IR

B

U

IL

D

IN

G

-2

-0

DOOR AND FRAME SCHEDULE

NUMBER

PANEL FRAME

FIRE

RATING HARDWARE SET

DETAILS

COMMENTS

NO. OF

PANELS WIDTH HEIGHT THICKNESS MATERIAL GLASS TYPE MATERIAL TYPE HEAD JAMB LEFT JAMB RIGHT SILL

027-I-1101A 2 3' - 0" 7' - 0" 1 3/4" HM F HM 1 N/A 02 L1 H1 H1 E1 PROVIDE ROOM IDENTIFICATION SIGN AS PER SPECIFICATIONS AND SIGN TYPE C,D OR E AS SELECTED BY THE CONTRACTING OFFICER..

027-I-1202 1 3' - 0" 7' - 0" 1 3/4" ALUM CTIG FG ALUM D N/A 04 C16 A1 A1 C16

027-I-1203 2 3' - 0" 7' - 0" 1 3/4" HM F HM 1 N/A 02 L6 H6 H6 E1 PROVIDE ROOM IDENTIFICATION SIGN AS PER SPECIFICATIONS AND SIGN TYPE C,D OR E AS SELECTED BY THE CONTRACTING OFFICER..

027-I-1206A 1 3' - 0" 7' - 0" 1 3/4" HM F HM 1 N/A 03 L12 H12 H12 E1 SIMILAR DETAIL WITHOUT THE EIFS. CENTER IN MASONRY WALL (TYP.) PROVIDE ROOM ID SIGN AS PER SPECIFICATIONS AND SIGN TYPE B FROM SHEET I-112.

027-I-1206B 1 3' - 0" 7' - 0" 1 3/4" HM F HM 1 N/A 03 L1 H1 H1 E1 PROVIDE ROOM IDENTIFICATION SIGN AS PER SPECIFICATIONS AND SIGN TYPE B FROM SHEET I-112.

027-I-1208 1 3' - 0" 7' - 0" 1 3/4" HM F HM 1 N/A 03 L1 H1 H1 E1 PROVIDE ROOM IDENTIFICATION SIGN AS PER SPECIFICATIONS AND SIGN TYPE A FROM SHEET I-112..

027-I-1301 2 3' - 0" 7' - 0" 1 3/4" HM F HM 1 N/A 02 L6 H6 H6 E1 PROVIDE ROOM IDENTIFICATION SIGN AS PER SPECIFICATIONS AND SIGN TYPE C,D OR E AS SELECTED BY THE CONTRACTING OFFICER..

027-I-1302 1 3' - 0" 7' - 0" 1 3/4" HM F HM 1 N/A 03 L6 H6 H6 E1 PROVIDE ROOM IDENTIFICATION SIGN AS PER SPECIFICATIONS AND SIGN TYPE C,D OR E AS SELECTED BY THE CONTRACTING OFFICER..

027E-E-028 2 3' - 0" 7' - 0" 1 3/4" ALUM CTIG FG ALUM C N/A 05 C16 A15 A15 C16 ALL EXTERIOR PANIC BARS TO BE PROVIDED WITH INTEGRAL BATTERY POWERED ALARM SYSTEM.

027E-E-029 1 3' - 0" 7' - 0" 1 3/4" HM CTIG G HM 2 N/A 01 L12 H12 H12 N/A ALL EXTERIOR PANIC BARS TO BE PROVIDED WITH INTEGRAL BATTERY POWERED ALARM SYSTEM.

027E-E-030 1 3' - 0" 7' - 0" 1 3/4" HM F HM 2 ALL EXTERIOR PANIC BARS TO BE PROVIDED WITH INTEGRAL BATTERY POWERED ALARM SYSTEM.

027N-E-020 10' - 0" 12' - 0" STL STL N/A N/A N/A N/A N/A N/A OVERHEAD COILING DOOR TO BE INSTALLED AT EXISTING OPENING. VERIFY DIMENSIONS ON SITE.

027N-E-025 1 3' - 0" 7' - 0" 1 3/4" ALUM CTIG FG ALUM 2 N/A 05 L12 H12 H12 C16 ALL EXTERIOR PANIC BARS TO BE PROVIDED WITH INTEGRAL BATTERY POWERED ALARM SYSTEM.

027N-E-028 1 3' - 9" 7' - 0" 1 3/4" HM F HM E N/A 05 H12 H12 C16 ALL EXTERIOR PANIC BARS TO BE PROVIDED WITH INTEGRAL BATTERY POWERED ALARM SYSTEM.

027S-E-030 2 3' - 0" 7' - 0" 1 3/4" ALUM CTIG FG ALUM C N/A 05 C16 A15 A15 C16 ALL EXTERIOR PANIC BARS TO BE PROVIDED WITH INTEGRAL BATTERY POWERED ALARM SYSTEM.

027S-E-033 2 3' - 0" 7' - 0" 1 3/4" ALUM CTIG FG ALUM C N/A 05 C16 A15 A15 C16 ALL EXTERIOR PANIC BARS TO BE PROVIDED WITH INTEGRAL BATTERY POWERED ALARM SYSTEM.

1/4" = 1'-0"

DOOR PANEL TYPES

1/4" = 1'-0"

INTERIOR FRAME TYPES

GLAZING TYPE DESCRIPTIONS

AGS ALL-GLASS STOREFRONT

CCG CERAMIC-COATED GLASS

CG CLEAR FLOAT GLASS

CIG CLEAR INSULATING GLASS

CTG CLEAR TEMPERED FLOAT GLASS

CTIG CLEAR TEMPERED INSULATING GLASS

FSP FIBERGLASS SANDWICH PANEL

GL GLASS

GT GLASS TILE

HSG HEAT-STRENGTHENED GLASS

IIP INSULATING INFILL PANEL GLASS

LG LAMINATED GLASS

LIG LAMINATED INSULATING GLASS

PG PATTERN GLASS

PIG PATTERN INSULATING GLASS

RCG REFLECTIVE-COATED GLASS

SG SPECIALTY GLASS

SPG SPANDREL GLASS

SPIG SPANDREL INSULATING GLASS

TFG TINTED FLOAT GLASS

TG TINTED FLOAT GLASS

TIG TINTED INSULATING GLASS

TTG TINTED TEMPERED FLOAT GLASS

TTIG TINTED TEMPERED INSULATING GLASS

WG WIRE GLASS

EXTERIOR WINDOW SCHEDULE

FRAME

FIRE RATING

DETAILS

COMMENTSTYPE DEPTH MATERIAL HEAD JAMB LEFT JAMB RIGHT SILL

B 4" ALUM N/A C10 E5 E5 C10 NEW WINDOWS TO MATCH EXISTING.

1/4" = 1'-0"

EXTERIOR FRAME ELEVATIONS

J1

F1

A1

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/3

/2

9/3/2026

W

2Q R

BA

1_

Pl an s-

A-502

K7

EXISTING METAL WALL PANEL AND STRUCTURE TO

REMAIN UNDISTURBED.

BACKER ROD AND CAULK AT JOINT (TYP).

NEW 1 1/2" EXTERIOR INSULATED FINISH SYSTEM (EIFS)

EXPANSION JOINT AS PER EIFS MANUFACTURER.

EXISTING METAL FLASHING TO REMAIN.

BACKER ROD AND CAULK BETWEEN METAL FLASHING AND NEW EIFS.

EXISTING METAL CANOPY OVER ENTRANCE DOOR TO REMAIN UNDISTURBED,

EXISTING CONCRETE BEAM.

NEW 1 1/2" EXTERIOR INSULATED FINISH SYSTEM (EIFS)

EXISTING MASONRY WALL TO REMAIN.

MIN.

6"

MIN.

6"

EXISTING MASONRY WALL OR CONCRETE STRUCTURAL MEMEBER.

INTERIOR FINISH PER FINISH PLANS AND SCHEDULE

EXTERIOR INSULATION FINISH SYSTEM (EIFS)

BUILD UP TO BYPASS EXISTING DUCT OR PIPE TO CLOSE TO

WALL TO EXTEND FINISH BEHIND IT.

FLUID APPLIED AIR WATER BARRIER. EXTEND AS FAR AS POSSIBLE.

INSULATION ADHESIVE INSTALLED TO

ALLOW CLEAR DRAINAGE

EPS INSULATION BOARD

REINFORCEMENT MESH

PROVIDE A MIN. 1/4" CLEAR FROM

DUCT OR PIPE. (TYP)

EXISTING DUCT OR PIPE ON WALL

4" DIAMETER OR LARGER. ALL

OTHER CONDUITS TO BE

TEMPORARILY REMOVED AND

REINSTALLED.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T R

A C

T N

O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

A u to d e s k D o c s /2

-2

-0

D

L A

D S

C C

B ld g

R

E m o d /2

-2

-0

D

L A

D S

C C

B ld g R

E P

F R e m o d A

R .r v t

/8

/2

:4

:1

P M

A-502

E X

T E

R

IO

R D

E T A

IL

S

C O

L U

M B

U S

O

H

IO

L O

U

IS

V

IL

L E

K

Y E

.E

E .E

A .B

E .B

M a rc h

C E

R T

IF

IE

D

F

IN

A L

D S

C C

D L A

R E

P A

IR

B

U

IL

D

IN

G

-2

-0

3/8" = 1'-0"E1

WALL SECTION

3/4" = 1'-0"K7

FLASHING DETAIL

NEW STOREFRONT DOOR. RE:

SCHEDULE.

EXISTING METAL CONOPY OVER

ENTRANCE DOOR TO REMAIN.

EXISTING METAL WALL TO REMAIN.

EXISTING LOUVERS TO REMAIN.

NEW EIFS OVER MASONRY WALLS

AND CONCRETE BEAMS AND

COLUMNS AS PER ELEVATIONS,

3/4" = 1'-0"K13

EIFS BYPASS DETAIL @ PIPES AND DUCTS CLOSE TO WALL

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/3

/2

9/3/2026

W

2Q R

BA

1_

Pl an s-

COILING DOOR TO BE REPLACED WITH

NEW INSULATED OVERHEAD DOOR

RESTROOM

STORAGE

ROOM

AEROBICS

ROOM

VH

RESTROOM

MECH. ROOM

RAQUETBALL

COURT

RAQUETBALL

COURT

MASSAGE

ROOM

BOXING

TRAINING

ROOM

IT CLOS.

LAUNDRY

ROOM

SPRINKLER

RISE

JANITOR

ROOM

STAIRS

CONFERENCE

ROOM

OFFICE

TRANSFORM.

STORAGE

ROOM

WEIGHT ROOM

SPIN ROOM

MEN'S

SHOWERS

MEN'S

RESTROOM

MEN'S

RESTROOM

WOMEN'S

LOCKER ROOM

WOMEN'S

SHOWERS

SAUNA

WOMEN'S

RESTROOM

ELEC. ROOM

AD201

B1

AD201

L1

WORKOUT

AREA

MEN'S LOCKER

ROOM

BASKETBALL

COURT

AD201G1

AD102

B1

AD103

B1

AD104

B1

AD105

B1

AD106

B1

AD107

B1

ELECTRICAL

CLOSET

SAUNA

A-402

DEMOLITION GENERAL NOTES

THE CONTRACTOR SHALL:

A. COORDINATE ALL DEMOLITION AND PHASING EFFORTS WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). EVERY EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF OCCUPANT'S OPERATIONS. EXCESSIVE NOISE OR VIBRATION SHALL BE PRE-APPROVED AND COORDINATED WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). IN ALL CASES, PROVISIONS SHALL BE MADE FOR

USER’S SAFETY.

B. COORDINATE ANY DISRUPTION OF UTILITY SERVICES WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND AS SPECIFIED.

C. CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHIN THE EXISTING BUILDING WHICH OFFER A ONE-HOUR ENCLOSURE TO ISOLATE ANY DEMOLITION/CONSTRUCTION WORK FROM THE GENERAL

PUBLIC AND AS DEEMED NECESSARY BY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND CODE OFFICIAL HAVING JURISDICTION. COORDINATE LOCATIONS WITH THE CONTRACTING OFFICER

REPRESENTATIVE (C0R) AND MAINTAIN MEANS OF EGRESS THROUGHOUT THE WORK.

D. MAINTAIN A SECURE, WEATHER-TIGHT ENCLOSURE AT ALL TIMES.

E. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS AND NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) OF ANY DISCREPANCIES.

F. REMOVE IN THEIR ENTIRETY ALL EXISTING WALLS, DOORS, MILLWORK, PLUMBING FIXTURES, CEILINGS, SOFFITS, WALL FIXTURES, AND OTHER ITEMS, AS REQUIRED TO EXECUTE THE

DEMOLITION/CONSTRUCTION WORK DESCRIBED BY THE DRAWINGS.

G. PROVIDE PROTECTION FOR ALL EXISTING BUILDING MATERIALS AND EQUIPMENT FROM DAMAGE DUE TO ANY DEMOLITION OR CONSTRUCTION-RELATED INCIDENT PERFORMED UNDER THIS CONTRACT.

H. REPAIR OR REPLACE ITEMS THAT ARE DAMAGED AS A RESULT OF DEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND/OR CONDITION.

I. NO EXISTING MATERIALS SHALL BE REUSED IN ANY INSTANCE. DISPOSE OF EXISTING DEMOLISHED MATERIALS AS PER SPECIFICATIONS.

J. VERIFY AND MAINTAIN THE LOCATION OF EXISTING POWER, COMMUNICATION AND DATA CABLES TO PREVENT INTERRUPTION OF THEIR SERVICE.

K. PATCH FLOOR, WALL AND CEILING PENETRATIONS RESULTING FROM REMOVAL OR RE-ROUTING OF NEW OR EXISTING PIPING, DUCTWORK, CONDUIT, AND OTHER ITEMS. FINISH AS REQUIRED FOR NEW OR

EXISTING ADJACENT SURFACES.

L. CAP ALL DISCONNECTED MECHANICAL PIPING LINES WITHIN THE WALL OR FLOOR. PATCH AND FINISH AS REQUIRED TO MATCH NEW OR EXISTING ADJACENT SURFACES.

M. SEE MECHANICAL AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

N. WHERE CMU WALLS ARE INDICATED TO BE REMOVED, PREPARE ADJACENT WALLS TO RECEIVE NEW PATCH/FINISH BY SAWCUTTING AND OR REMOVING CMU IN TOOTH-IN PATTERN BOTH SIDES OF DEMOLITION

FOR CONTRACTOR TO TOOTH-IN NEW CMU PATCHES AS NEEDED.

O. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

P. COORDINATE WITH HAZARDOUS ABATEMENT SHEETS AND REPORT BEFORE ANY DEMOLITION TAKES PLACE.

DEMOLITION NOTES APPLY TO ALL DEMOLITION SHEETS.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T R

A C

T N

O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

A u to d e s k D o c s /2

-2

-0

D

L A

D S

C C

B ld g

R

E m o d /2

-2

-0

D

L A

D S

C C

B ld g R

E P

F R e m o d A

R .r v t

/8

/2

:5

:3

P M

AD101

D E

M O

L

IT

IO

N

P L A

N O

V E

R A

L L

C O

L U

M B

U S

O

H

IO

L O

U

IS

V

IL

L E

K

Y E

.E

E .E

A .B

E .B

M a rc h

C E

R T

IF

IE

D

F

IN

A L

D S

C C

D L A

R E

P A

IR

B

U

IL

D

IN

G

-2

-0

1/16" = 1'-0"C1

OVERALL DEMOLITION PLAN, LEVEL 1

0 10 20

SCALE: 1/16" = 1'=0"

GLASS WALL TO BE

REMOVED

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/3

/2

9/3/2026 W

2Q R

BA

1_

Pl an s-

DEMOLITION GENERAL NOTES

THE CONTRACTOR SHALL:

A. COORDINATE ALL DEMOLITION AND PHASING EFFORTS WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). EVERY EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF OCCUPANT'S OPERATIONS. EXCESSIVE NOISE OR VIBRATION SHALL BE PRE-APPROVED AND COORDINATED WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). IN ALL CASES, PROVISIONS SHALL BE MADE FOR

USER’S SAFETY.

B. COORDINATE ANY DISRUPTION OF UTILITY SERVICES WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND AS SPECIFIED.

C. CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHIN THE EXISTING BUILDING WHICH OFFER A ONE-HOUR ENCLOSURE TO ISOLATE ANY DEMOLITION/CONSTRUCTION WORK FROM THE GENERAL

PUBLIC AND AS DEEMED NECESSARY BY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND CODE OFFICIAL HAVING JURISDICTION. COORDINATE LOCATIONS WITH THE CONTRACTING OFFICER

REPRESENTATIVE (C0R) AND MAINTAIN MEANS OF EGRESS THROUGHOUT THE WORK.

D. MAINTAIN A SECURE, WEATHER-TIGHT ENCLOSURE AT ALL TIMES.

E. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS AND NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) OF ANY DISCREPANCIES.

F. REMOVE IN THEIR ENTIRETY ALL EXISTING WALLS, DOORS, MILLWORK, PLUMBING FIXTURES, CEILINGS, SOFFITS, WALL FIXTURES, AND OTHER ITEMS, AS REQUIRED TO EXECUTE THE

DEMOLITION/CONSTRUCTION WORK DESCRIBED BY THE DRAWINGS.

G. PROVIDE PROTECTION FOR ALL EXISTING BUILDING MATERIALS AND EQUIPMENT FROM DAMAGE DUE TO ANY DEMOLITION OR CONSTRUCTION-RELATED INCIDENT PERFORMED UNDER THIS CONTRACT.

H. REPAIR OR REPLACE ITEMS THAT ARE DAMAGED AS A RESULT OF DEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND/OR CONDITION.

I. NO EXISTING MATERIALS SHALL BE REUSED IN ANY INSTANCE. DISPOSE OF EXISTING DEMOLISHED MATERIALS AS PER SPECIFICATIONS.

J. VERIFY AND MAINTAIN THE LOCATION OF EXISTING POWER, COMMUNICATION AND DATA CABLES TO PREVENT INTERRUPTION OF THEIR SERVICE.

K. PATCH FLOOR, WALL AND CEILING PENETRATIONS RESULTING FROM REMOVAL OR RE-ROUTING OF NEW OR EXISTING PIPING, DUCTWORK, CONDUIT, AND OTHER ITEMS. FINISH AS REQUIRED FOR NEW OR

EXISTING ADJACENT SURFACES.

L. CAP ALL DISCONNECTED MECHANICAL PIPING LINES WITHIN THE WALL OR FLOOR. PATCH AND FINISH AS REQUIRED TO MATCH NEW OR EXISTING ADJACENT SURFACES.

M. SEE MECHANICAL AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

N. WHERE CMU WALLS ARE INDICATED TO BE REMOVED, PREPARE ADJACENT WALLS TO RECEIVE NEW PATCH/FINISH BY SAWCUTTING AND OR REMOVING CMU IN TOOTH-IN PATTERN BOTH SIDES OF DEMOLITION

FOR CONTRACTOR TO TOOTH-IN NEW CMU PATCHES AS NEEDED.

O. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

P. COORDINATE WITH HAZARDOUS ABATEMENT SHEETS AND REPORT BEFORE ANY DEMOLITION TAKES PLACE.

DEMOLITION NOTES APPLY TO ALL DEMOLITION SHEETS.

CONFERENCE

ROOM

RESTROOM

LAUNDRY

ROOM

OFFICE

STORAGE

ROOM

WORKOUT

AREA

STORAGE

ROOM

IT CLOS.

TRANSFORM.

DEMO SHEET NOTES#

T R

U E

N

WOMEN'S

LOCKER

MEN'S

LOCKER

MECHANICAL

ROOM

20' - 3 3/ 8"

SAUNA

SAUNA

6' - 10"

MEN'S

WOMEN'S

WOMEN

MEN

HC

SHOWER

MECH

ROOM

TYP

21 6

LOCKER

WOMEN'S

P / B/ F 24 P / B/ F 24

P

B/ F

P

B/

F

P/B/F 24 P/B/F 24

P

B/ F

P

B/

F

AREA NOT IN SCOPE

AREA OF WORK

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T R

A C

T N

O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

KEYPLAN

SCALE: N.T.S.

A u to d e s k D o c s /2

-2

-0

D

L A

D S

C C

B ld g

R

E m o d /2

-2

-0

D

L A

D S

C C

B ld g R

E P

F R e m o d A

R .r v t

/8

/2

:4

:1

P M

AD102

D E

M O

L

IT

IO

N

P L A

N

A R

E A

N

C O

L U

M B

U S

O

H

IO

L O

U

IS

V

IL

L E

K

Y E

.E

E .E

A .B

E .B

M a rc h

C E

R T

IF

IE

D

F

IN

A L

D S

C C

D L A

R E

P A

IR

B

U

IL

D

IN

G

-2

-0

1/8" = 1'-0"B1

OVERALL DEMOLITION PLAN - AREA 11-N

0 5 10

SCALE: 1/8" = 1'=0"

1 EXISTING OVERHEAD COILING DOOR TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING DOOR AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

2 EXISTING EXTERIOR DOOR AND FRAME TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING DOOR AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

3 EXISTING EXTERIOR WINDOW TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING WINDOW AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

4 EXISTING EXTERIOR LOUVER TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING LOUVER AND PREPARE OPENING TO BE FILLED AS

PER STRUCTURAL DETAILS.

5 EXISTING INTERIOR DOOR AND FRAME TO BE REMOVED.

6 INCREASE ROUGH OPENING SIZE TO ACCOMODATE A NEW PAIR 3-0 DOORS.

7 EXISTING OVERHEAD DOOR TO REMAIN IN PLACE.

8 EXISTING WINDOW TO REMAIN IN PLACE .

9 EXISTING EXTERIOR DOOR TO REMAIN IN PLACE.

10 EXISTING GLASS WALL TO BE REMOVED. REMOVE ALL FASTENERS AND BRACKETS IN PREPARATION TO INSTALL A NEW METAL STUD WALL AS PER PLANS.

11 EXISTING WALL AND WALL MOUNTED ITEMS TO BE REMOVED. VERIFY DIMENSIONS ON SITE.

12 EXISTING VIEWING WINDOW INTO RACQUET BALL COURT TO BE REMOVED.

13 EXISTING RACQUET BALL FLOORING TO BE REMOVED TO CONCRETE SLAB. PREPARE CONCRETE SLAB TO RECEIVE NEW FLOORING AS PER FINISH SCHEDULE.

14 EXISTING RACQUET BALL HARD CEILING TO BE REMOVED. RE: MEP DRAWINGS FOR ADDITIONAL INFORMATION.

15 NEW DOOR OPENING FOR NEW ACCESS DOOR TO RACQUET BALL COURT.

16 DIMENSION TO BE VERIFIED IN FIELD. APPROXIMATE BASED ON EXISTING DOCUMENTS.

17 EXISTING SUSPENDED ACCOUSTICAL CEILING SYSTEM TO BE REMOVED.. RE:MEP FOR ADDITIONAL INFORMATION.

18 EXISTING FLOORING TO BE REMOVED TO CONCRETE SLAB. PREPARE EXISTING SLAB FOR NEW FLOORING AS PER FINISH SCHEDULE.

19 EXISTING WALL PADDING TO BE REMOVED.

20 EXISTING MECHANICAL MEZZANINE ABOVE THIS AREA TO BE REMOVED AS PER SHEET AD108 (DECKING ONLY - STRUCTURAL MEMBERS TO REMAIN IN PLACE).

21 EXISTING LADDER TO MEZZANINE TO BE REMOVED WITH ALL COMPONENTS, INCLUDING BUT NOT LIMITED TO FASTENERS, BRACKETS, ETC.. REPAIR WALL, PATCH HOLES, REPAIR FLOORING AND REFINISH WALL AND FLOOR TO MATCH ADJACENT.

22 EXISTING ELECTRICAL CLOSET TO REMAIN IN PLACE. PROTECT DURING DEMOLITION.

23 EXISTING FLOORING DECK TO BE REMOVED. JOIST TO REMAIN IN PLACE.

24 REMOVE ALL DEBRIS LEFT OUT FROM MECHANICAL AND ELECTRICAL DEMOLITION WORK LEFT BEHIND INCLUDING BUT NOT LIMITED TO FASTENERS, HANGERS, METAL PANS, ETC.

25 REMOVE EXISTING ACCESS LADDER AND ALL ASSOCIATED HARDWARE. PATCH HOLES AND REPAINT WALLS AS NEEDED. PATCH AND CLEAN UP FLOOR TO

MATCH EXISTING.

26 EXISTING METAL CAGE TO BE REMOVED. PATCH ALL HOLES, AND REPAIR ANY OTHER DAMAGES AROUND THE WINDOW OPENING TO MATCH ADJACENT

WALLS.

27 EXISTING FAN IN CAGE TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING FAN INCLUDING THE CAGE AND PREPARE OPENING TO BE FILLED AS PER STRUCTURAL DETAILS. RE: MECHANICAL DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION.

28 REMOVE EXISTING VINYL FLOORING AND PREPARE SUBSTRATE FOR INSTALLATION OF NEW VINYL FLOORING.

29 SAW CUT BRICK BELOW THE EXISTING WINDOW TO EXTEND THE EXISTING OPENING TO THE FLOOR, CLEAN AND PREPARE TO RECEIVE NEW BLOCK NEW HM

DOOR AND FRAME.

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/3

/2

9/3/2026

W

2Q R

BA

1_

Pl an s-

A. COORDINATE ALL DEMOLITION AND PHASING EFFORTS WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). EVERY EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF OCCUPANT'S OPERATIONS. EXCESSIVE NOISE OR VIBRATION SHALL BE PRE-APPROVED AND COORDINATED WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). IN ALL CASES, PROVISIONS SHALL BE MADE FOR

USER’S SAFETY.

B. COORDINATE ANY DISRUPTION OF UTILITY SERVICES WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND AS SPECIFIED.

C. CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHIN THE EXISTING BUILDING WHICH OFFER A ONE-HOUR ENCLOSURE TO ISOLATE ANY DEMOLITION/CONSTRUCTION WORK FROM THE GENERAL

PUBLIC AND AS DEEMED NECESSARY BY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND CODE OFFICIAL HAVING JURISDICTION. COORDINATE LOCATIONS WITH THE CONTRACTING OFFICER

REPRESENTATIVE (C0R) AND MAINTAIN MEANS OF EGRESS THROUGHOUT THE WORK.

D. MAINTAIN A SECURE, WEATHER-TIGHT ENCLOSURE AT ALL TIMES.

E. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS AND NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) OF ANY DISCREPANCIES.

F. REMOVE IN THEIR ENTIRETY ALL EXISTING WALLS, DOORS, MILLWORK, PLUMBING FIXTURES, CEILINGS, SOFFITS, WALL FIXTURES, AND OTHER ITEMS, AS REQUIRED TO EXECUTE THE

DEMOLITION/CONSTRUCTION WORK DESCRIBED BY THE DRAWINGS.

G. PROVIDE PROTECTION FOR ALL EXISTING BUILDING MATERIALS AND EQUIPMENT FROM DAMAGE DUE TO ANY DEMOLITION OR CONSTRUCTION-RELATED INCIDENT PERFORMED UNDER THIS CONTRACT.

H. REPAIR OR REPLACE ITEMS THAT ARE DAMAGED AS A RESULT OF DEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND/OR CONDITION.

I. NO EXISTING MATERIALS SHALL BE REUSED IN ANY INSTANCE. DISPOSE OF EXISTING DEMOLISHED MATERIALS AS PER SPECIFICATIONS.

J. VERIFY AND MAINTAIN THE LOCATION OF EXISTING POWER, COMMUNICATION AND DATA CABLES TO PREVENT INTERRUPTION OF THEIR SERVICE.

K. PATCH FLOOR, WALL AND CEILING PENETRATIONS RESULTING FROM REMOVAL OR RE-ROUTING OF NEW OR EXISTING PIPING, DUCTWORK, CONDUIT, AND OTHER ITEMS. FINISH AS REQUIRED FOR NEW OR

EXISTING ADJACENT SURFACES.

L. CAP ALL DISCONNECTED MECHANICAL PIPING LINES WITHIN THE WALL OR FLOOR. PATCH AND FINISH AS REQUIRED TO MATCH NEW OR EXISTING ADJACENT SURFACES.

M. SEE MECHANICAL AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

N. WHERE CMU WALLS ARE INDICATED TO BE REMOVED, PREPARE ADJACENT WALLS TO RECEIVE NEW PATCH/FINISH BY SAWCUTTING AND OR REMOVING CMU IN TOOTH-IN PATTERN BOTH SIDES OF DEMOLITION

FOR CONTRACTOR TO TOOTH-IN NEW CMU PATCHES AS NEEDED.

O. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

P. COORDINATE WITH HAZARDOUS ABATEMENT SHEETS AND REPORT BEFORE ANY DEMOLITION TAKES PLACE.

DEMOLITION NOTES APPLY TO ALL DEMOLITION SHEETS.

8' - 9 1/2" +/- VIF

BASKETBALL

COURT

MEN'S

RESTROOM

MEN'S

SHOWERS

MECH. ROOM

WOMEN'S

RESTROOM

WOMEN'S

SHOWERS

WOMEN'S

LOCKER ROOM

SPRINKLER

RISE

2 3

32' - 2" +/- VIF

26 26

SAUNA

SAUNA

A-402

DEMO SHEET NOTES#

WOMEN'S

LOCKER

MEN'S

LOCKER

MECHANICAL

ROOM

20' - 3 3/ 8"

SAUNA

SAUNA

6' - 10"

MEN'S

WOMEN'S

WOMEN

MEN

HC

SHOWER

MECH

ROOM

TYP

21 6

LOCKER

WOMEN'S

P / B/ F 24 P / B/ F 24

P

B/ F

P

B/

F

P/B/F 24 P/B/F 24

P

B/ F

P

B/

F

AREA NOT IN SCOPE

AREA OF WORK

WOMEN'S

LOCKER

MEN'S

LOCKER

MECHANICAL

ROOM

20' - 3 3/ 8"

SAUNA

SAUNA

6' - 10"

MEN'S

WOMEN'S

WOMEN

MEN

HC

SHOWER

MECH

ROOM

TYP

21 6

LOCKER

WOMEN'S

P / B/ F 24 P / B/ F 24

P

B/ F

P

B/

F

P/B/F 24 P/B/F 24

P

B/ F

P

B/

F

AREA NOT IN SCOPE

AREA OF WORK

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T R

A C

T N

O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

A u to d e s k D o c s /2

-2

-0

D

L A

D S

C C

B ld g

R

E m o d /2

-2

-0

D

L A

D S

C C

B ld g R

E P

F R e m o d A

R .r v t

/8

/2

:4

:2

P M

AD103

D E

M O

L

IT

IO

N

P L A

N

A R

E A

N

C O

L U

M B

U S

O

H

IO

L O

U

IS

V

IL

L E

K

Y E

.E

E .E

A .B

E .B

M a rc h

C E

R T

IF

IE

D

F

IN

A L

D S

C C

D L A

R E

P A

IR

B

U

IL

D

IN

G

-2

-0

1/8" = 1'-0"B1

OVERALL DEMOLITION PLAN - AREA 12-N

0 5 10

SCALE: 1/8" = 1'=0"

1 EXISTING OVERHEAD COILING DOOR TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING DOOR AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

2 EXISTING EXTERIOR DOOR AND FRAME TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING DOOR AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

3 EXISTING EXTERIOR WINDOW TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING WINDOW AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

4 EXISTING EXTERIOR LOUVER TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING LOUVER AND PREPARE OPENING TO BE FILLED AS

PER STRUCTURAL DETAILS.

5 EXISTING INTERIOR DOOR AND FRAME TO BE REMOVED.

6 INCREASE ROUGH OPENING SIZE TO ACCOMODATE A NEW PAIR 3-0 DOORS.

7 EXISTING OVERHEAD DOOR TO REMAIN IN PLACE.

8 EXISTING WINDOW TO REMAIN IN PLACE .

9 EXISTING EXTERIOR DOOR TO REMAIN IN PLACE.

10 EXISTING GLASS WALL TO BE REMOVED. REMOVE ALL FASTENERS AND BRACKETS IN PREPARATION TO INSTALL A NEW METAL STUD WALL AS PER PLANS.

11 EXISTING WALL AND WALL MOUNTED ITEMS TO BE REMOVED. VERIFY DIMENSIONS ON SITE.

12 EXISTING VIEWING WINDOW INTO RACQUET BALL COURT TO BE REMOVED.

13 EXISTING RACQUET BALL FLOORING TO BE REMOVED TO CONCRETE SLAB. PREPARE CONCRETE SLAB TO RECEIVE NEW FLOORING AS PER FINISH SCHEDULE.

14 EXISTING RACQUET BALL HARD CEILING TO BE REMOVED. RE: MEP DRAWINGS FOR ADDITIONAL INFORMATION.

15 NEW DOOR OPENING FOR NEW ACCESS DOOR TO RACQUET BALL COURT.

16 DIMENSION TO BE VERIFIED IN FIELD. APPROXIMATE BASED ON EXISTING DOCUMENTS.

17 EXISTING SUSPENDED ACCOUSTICAL CEILING SYSTEM TO BE REMOVED.. RE:MEP FOR ADDITIONAL INFORMATION.

18 EXISTING FLOORING TO BE REMOVED TO CONCRETE SLAB. PREPARE EXISTING SLAB FOR NEW FLOORING AS PER FINISH SCHEDULE.

19 EXISTING WALL PADDING TO BE REMOVED.

20 EXISTING MECHANICAL MEZZANINE ABOVE THIS AREA TO BE REMOVED AS PER SHEET AD108 (DECKING ONLY - STRUCTURAL MEMBERS TO REMAIN IN PLACE).

21 EXISTING LADDER TO MEZZANINE TO BE REMOVED WITH ALL COMPONENTS, INCLUDING BUT NOT LIMITED TO FASTENERS, BRACKETS, ETC.. REPAIR WALL, PATCH HOLES, REPAIR FLOORING AND REFINISH WALL AND FLOOR TO MATCH ADJACENT.

22 EXISTING ELECTRICAL CLOSET TO REMAIN IN PLACE. PROTECT DURING DEMOLITION.

23 EXISTING FLOORING DECK TO BE REMOVED. JOIST TO REMAIN IN PLACE.

24 REMOVE ALL DEBRIS LEFT OUT FROM MECHANICAL AND ELECTRICAL DEMOLITION WORK LEFT BEHIND INCLUDING BUT NOT LIMITED TO FASTENERS, HANGERS, METAL PANS, ETC.

25 REMOVE EXISTING ACCESS LADDER AND ALL ASSOCIATED HARDWARE. PATCH HOLES AND REPAINT WALLS AS NEEDED. PATCH AND CLEAN UP FLOOR TO

MATCH EXISTING.

26 EXISTING METAL CAGE TO BE REMOVED. PATCH ALL HOLES, AND REPAIR ANY OTHER DAMAGES AROUND THE WINDOW OPENING TO MATCH ADJACENT

WALLS.

27 EXISTING FAN IN CAGE TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING FAN INCLUDING THE CAGE AND PREPARE OPENING TO BE FILLED AS PER STRUCTURAL DETAILS. RE: MECHANICAL DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION.

28 REMOVE EXISTING VINYL FLOORING AND PREPARE SUBSTRATE FOR INSTALLATION OF NEW VINYL FLOORING.

29 SAW CUT BRICK BELOW THE EXISTING WINDOW TO EXTEND THE EXISTING OPENING TO THE FLOOR, CLEAN AND PREPARE TO RECEIVE NEW BLOCK NEW HM

DOOR AND FRAME.

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/3

/2

9/3/2026

W

2Q R

BA

1_

Pl an s-

A. COORDINATE ALL DEMOLITION AND PHASING EFFORTS WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). EVERY EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF OCCUPANT'S OPERATIONS. EXCESSIVE NOISE OR VIBRATION SHALL BE PRE-APPROVED AND COORDINATED WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). IN ALL CASES, PROVISIONS SHALL BE MADE FOR

USER’S SAFETY.

B. COORDINATE ANY DISRUPTION OF UTILITY SERVICES WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND AS SPECIFIED.

C. CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHIN THE EXISTING BUILDING WHICH OFFER A ONE-HOUR ENCLOSURE TO ISOLATE ANY DEMOLITION/CONSTRUCTION WORK FROM THE GENERAL

PUBLIC AND AS DEEMED NECESSARY BY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND CODE OFFICIAL HAVING JURISDICTION. COORDINATE LOCATIONS WITH THE CONTRACTING OFFICER

REPRESENTATIVE (C0R) AND MAINTAIN MEANS OF EGRESS THROUGHOUT THE WORK.

D. MAINTAIN A SECURE, WEATHER-TIGHT ENCLOSURE AT ALL TIMES.

E. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS AND NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) OF ANY DISCREPANCIES.

F. REMOVE IN THEIR ENTIRETY ALL EXISTING WALLS, DOORS, MILLWORK, PLUMBING FIXTURES, CEILINGS, SOFFITS, WALL FIXTURES, AND OTHER ITEMS, AS REQUIRED TO EXECUTE THE

DEMOLITION/CONSTRUCTION WORK DESCRIBED BY THE DRAWINGS.

G. PROVIDE PROTECTION FOR ALL EXISTING BUILDING MATERIALS AND EQUIPMENT FROM DAMAGE DUE TO ANY DEMOLITION OR CONSTRUCTION-RELATED INCIDENT PERFORMED UNDER THIS CONTRACT.

H. REPAIR OR REPLACE ITEMS THAT ARE DAMAGED AS A RESULT OF DEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND/OR CONDITION.

I. NO EXISTING MATERIALS SHALL BE REUSED IN ANY INSTANCE. DISPOSE OF EXISTING DEMOLISHED MATERIALS AS PER SPECIFICATIONS.

J. VERIFY AND MAINTAIN THE LOCATION OF EXISTING POWER, COMMUNICATION AND DATA CABLES TO PREVENT INTERRUPTION OF THEIR SERVICE.

K. PATCH FLOOR, WALL AND CEILING PENETRATIONS RESULTING FROM REMOVAL OR RE-ROUTING OF NEW OR EXISTING PIPING, DUCTWORK, CONDUIT, AND OTHER ITEMS. FINISH AS REQUIRED FOR NEW OR

EXISTING ADJACENT SURFACES.

L. CAP ALL DISCONNECTED MECHANICAL PIPING LINES WITHIN THE WALL OR FLOOR. PATCH AND FINISH AS REQUIRED TO MATCH NEW OR EXISTING ADJACENT SURFACES.

M. SEE MECHANICAL AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

N. WHERE CMU WALLS ARE INDICATED TO BE REMOVED, PREPARE ADJACENT WALLS TO RECEIVE NEW PATCH/FINISH BY SAWCUTTING AND OR REMOVING CMU IN TOOTH-IN PATTERN BOTH SIDES OF DEMOLITION

FOR CONTRACTOR TO TOOTH-IN NEW CMU PATCHES AS NEEDED.

O. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

P. COORDINATE WITH HAZARDOUS ABATEMENT SHEETS AND REPORT BEFORE ANY DEMOLITION TAKES PLACE.

DEMOLITION NOTES APPLY TO ALL DEMOLITION SHEETS.

WEIGHT ROOM

VOLLEYBALL

COURT

RAQUETBALL

COURT

WORKOUT

AREA

MASSAGE

ROOM

STAIRS

RESTROOM

VH

1308JANITOR

ROOM

9 8 8

DEMO SHEET NOTES#

T R

U E

N

WOMEN'S

LOCKER

MEN'S

LOCKER

MECHANICAL

ROOM

20' - 3 3/ 8"

SAUNA

SAUNA

6' - 10"

MEN'S

WOMEN'S

WOMEN

MEN

HC

SHOWER

MECH

ROOM

TYP

21 6

LOCKER

WOMEN'S

P / B/ F 24 P / B/ F 24

P

B/ F

P

B/

F

P/B/F 24 P/B/F 24

P

B/ F

P

B/

F

AREA NOT IN SCOPE

AREA OF WORK

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T R

A C

T N

O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

KEYPLAN

SCALE: N.T.S.

A u to d e s k D o c s /2

-2

-0

D

L A

D S

C C

B ld g

R

E m o d /2

-2

-0

D

L A

D S

C C

B ld g R

E P

F R e m o d A

R .r v t

/8

/2

:4

:2

P M

AD104

D E

M O

L

IT

IO

N

P L A

N

A R

E A

N

C O

L U

M B

U S

O

H

IO

L O

U

IS

V

IL

L E

K

Y E

.E

E .E

A .B

E .B

M a rc h

C E

R T

IF

IE

D

F

IN

A L

D S

C C

D L A

R E

P A

IR

B

U

IL

D

IN

G

-2

-0

1/8" = 1'-0"B1

OVERALL DEMOLITION PLAN - AREA 13-N

0 5 10

SCALE: 1/8" = 1'=0"

1 EXISTING OVERHEAD COILING DOOR TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING DOOR AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

2 EXISTING EXTERIOR DOOR AND FRAME TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING DOOR AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

3 EXISTING EXTERIOR WINDOW TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING WINDOW AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

4 EXISTING EXTERIOR LOUVER TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING LOUVER AND PREPARE OPENING TO BE FILLED AS

PER STRUCTURAL DETAILS.

5 EXISTING INTERIOR DOOR AND FRAME TO BE REMOVED.

6 INCREASE ROUGH OPENING SIZE TO ACCOMODATE A NEW PAIR 3-0 DOORS.

7 EXISTING OVERHEAD DOOR TO REMAIN IN PLACE.

8 EXISTING WINDOW TO REMAIN IN PLACE .

9 EXISTING EXTERIOR DOOR TO REMAIN IN PLACE.

10 EXISTING GLASS WALL TO BE REMOVED. REMOVE ALL FASTENERS AND BRACKETS IN PREPARATION TO INSTALL A NEW METAL STUD WALL AS PER PLANS.

11 EXISTING WALL AND WALL MOUNTED ITEMS TO BE REMOVED. VERIFY DIMENSIONS ON SITE.

12 EXISTING VIEWING WINDOW INTO RACQUET BALL COURT TO BE REMOVED.

13 EXISTING RACQUET BALL FLOORING TO BE REMOVED TO CONCRETE SLAB. PREPARE CONCRETE SLAB TO RECEIVE NEW FLOORING AS PER FINISH SCHEDULE.

14 EXISTING RACQUET BALL HARD CEILING TO BE REMOVED. RE: MEP DRAWINGS FOR ADDITIONAL INFORMATION.

15 NEW DOOR OPENING FOR NEW ACCESS DOOR TO RACQUET BALL COURT.

16 DIMENSION TO BE VERIFIED IN FIELD. APPROXIMATE BASED ON EXISTING DOCUMENTS.

17 EXISTING SUSPENDED ACCOUSTICAL CEILING SYSTEM TO BE REMOVED.. RE:MEP FOR ADDITIONAL INFORMATION.

18 EXISTING FLOORING TO BE REMOVED TO CONCRETE SLAB. PREPARE EXISTING SLAB FOR NEW FLOORING AS PER FINISH SCHEDULE.

19 EXISTING WALL PADDING TO BE REMOVED.

20 EXISTING MECHANICAL MEZZANINE ABOVE THIS AREA TO BE REMOVED AS PER SHEET AD108 (DECKING ONLY - STRUCTURAL MEMBERS TO REMAIN IN PLACE).

21 EXISTING LADDER TO MEZZANINE TO BE REMOVED WITH ALL COMPONENTS, INCLUDING BUT NOT LIMITED TO FASTENERS, BRACKETS, ETC.. REPAIR WALL, PATCH HOLES, REPAIR FLOORING AND REFINISH WALL AND FLOOR TO MATCH ADJACENT.

22 EXISTING ELECTRICAL CLOSET TO REMAIN IN PLACE. PROTECT DURING DEMOLITION.

23 EXISTING FLOORING DECK TO BE REMOVED. JOIST TO REMAIN IN PLACE.

24 REMOVE ALL DEBRIS LEFT OUT FROM MECHANICAL AND ELECTRICAL DEMOLITION WORK LEFT BEHIND INCLUDING BUT NOT LIMITED TO FASTENERS, HANGERS, METAL PANS, ETC.

25 REMOVE EXISTING ACCESS LADDER AND ALL ASSOCIATED HARDWARE. PATCH HOLES AND REPAINT WALLS AS NEEDED. PATCH AND CLEAN UP FLOOR TO

MATCH EXISTING.

26 EXISTING METAL CAGE TO BE REMOVED. PATCH ALL HOLES, AND REPAIR ANY OTHER DAMAGES AROUND THE WINDOW OPENING TO MATCH ADJACENT

WALLS.

27 EXISTING FAN IN CAGE TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING FAN INCLUDING THE CAGE AND PREPARE OPENING TO BE FILLED AS PER STRUCTURAL DETAILS. RE: MECHANICAL DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION.

28 REMOVE EXISTING VINYL FLOORING AND PREPARE SUBSTRATE FOR INSTALLATION OF NEW VINYL FLOORING.

29 SAW CUT BRICK BELOW THE EXISTING WINDOW TO EXTEND THE EXISTING OPENING TO THE FLOOR, CLEAN AND PREPARE TO RECEIVE NEW BLOCK NEW HM

DOOR AND FRAME.

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/3

/2

9/3/2026

W

2Q R

BA

1_

Pl an s-

A. COORDINATE ALL DEMOLITION AND PHASING EFFORTS WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). EVERY EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF OCCUPANT'S OPERATIONS. EXCESSIVE NOISE OR VIBRATION SHALL BE PRE-APPROVED AND COORDINATED WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). IN ALL CASES, PROVISIONS SHALL BE MADE FOR

USER’S SAFETY.

B. COORDINATE ANY DISRUPTION OF UTILITY SERVICES WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND AS SPECIFIED.

C. CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHIN THE EXISTING BUILDING WHICH OFFER A ONE-HOUR ENCLOSURE TO ISOLATE ANY DEMOLITION/CONSTRUCTION WORK FROM THE GENERAL

PUBLIC AND AS DEEMED NECESSARY BY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND CODE OFFICIAL HAVING JURISDICTION. COORDINATE LOCATIONS WITH THE CONTRACTING OFFICER

REPRESENTATIVE (C0R) AND MAINTAIN MEANS OF EGRESS THROUGHOUT THE WORK.

D. MAINTAIN A SECURE, WEATHER-TIGHT ENCLOSURE AT ALL TIMES.

E. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS AND NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) OF ANY DISCREPANCIES.

F. REMOVE IN THEIR ENTIRETY ALL EXISTING WALLS, DOORS, MILLWORK, PLUMBING FIXTURES, CEILINGS, SOFFITS, WALL FIXTURES, AND OTHER ITEMS, AS REQUIRED TO EXECUTE THE

DEMOLITION/CONSTRUCTION WORK DESCRIBED BY THE DRAWINGS.

G. PROVIDE PROTECTION FOR ALL EXISTING BUILDING MATERIALS AND EQUIPMENT FROM DAMAGE DUE TO ANY DEMOLITION OR CONSTRUCTION-RELATED INCIDENT PERFORMED UNDER THIS CONTRACT.

H. REPAIR OR REPLACE ITEMS THAT ARE DAMAGED AS A RESULT OF DEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND/OR CONDITION.

I. NO EXISTING MATERIALS SHALL BE REUSED IN ANY INSTANCE. DISPOSE OF EXISTING DEMOLISHED MATERIALS AS PER SPECIFICATIONS.

J. VERIFY AND MAINTAIN THE LOCATION OF EXISTING POWER, COMMUNICATION AND DATA CABLES TO PREVENT INTERRUPTION OF THEIR SERVICE.

K. PATCH FLOOR, WALL AND CEILING PENETRATIONS RESULTING FROM REMOVAL OR RE-ROUTING OF NEW OR EXISTING PIPING, DUCTWORK, CONDUIT, AND OTHER ITEMS. FINISH AS REQUIRED FOR NEW OR

EXISTING ADJACENT SURFACES.

L. CAP ALL DISCONNECTED MECHANICAL PIPING LINES WITHIN THE WALL OR FLOOR. PATCH AND FINISH AS REQUIRED TO MATCH NEW OR EXISTING ADJACENT SURFACES.

M. SEE MECHANICAL AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

N. WHERE CMU WALLS ARE INDICATED TO BE REMOVED, PREPARE ADJACENT WALLS TO RECEIVE NEW PATCH/FINISH BY SAWCUTTING AND OR REMOVING CMU IN TOOTH-IN PATTERN BOTH SIDES OF DEMOLITION

FOR CONTRACTOR TO TOOTH-IN NEW CMU PATCHES AS NEEDED.

O. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

P. COORDINATE WITH HAZARDOUS ABATEMENT SHEETS AND REPORT BEFORE ANY DEMOLITION TAKES PLACE.

DEMOLITION NOTES APPLY TO ALL DEMOLITION SHEETS.

WORKOUT

AREA

AEROBICS

ROOM

BOXING

TRAINING

ROOM

STORAGE

ROOM

17 8 89

DEMO SHEET NOTES#

T R

U E

N

WOMEN'S

LOCKER

MEN'S

LOCKER

MECHANICAL

ROOM

20' - 3 3/ 8"

SAUNA

SAUNA

6' - 10"

MEN'S

WOMEN'S

WOMEN

MEN

HC

SHOWER

MECH

ROOM

TYP

21 6

LOCKER

WOMEN'S

P / B/ F 24 P / B/ F 24

P

B/ F

P

B/

F

P/B/F 24 P/B/F 24

P

B/ F

P

B/

F

AREA NOT IN SCOPE

AREA OF WORK

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T R

A C

T N

O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

KEYPLAN

SCALE: N.T.S.

A u to d e s k D o c s /2

-2

-0

D

L A

D S

C C

B ld g

R

E m o d /2

-2

-0

D

L A

D S

C C

B ld g R

E P

F R e m o d A

R .r v t

/8

/2

:4

:2

P M

AD105

D E

M O

L

IT

IO

N

P L A

N

A R

E A

S

C O

L U

M B

U S

O

H

IO

L O

U

IS

V

IL

L E

K

Y E

.E

E .E

A .B

E .B

M a rc h

C E

R T

IF

IE

D

F

IN

A L

D S

C C

D L A

R E

P A

IR

B

U

IL

D

IN

G

-2

-0

1/8" = 1'-0"B1

OVERALL DEMOLITION PLAN - AREA 11-S

0 5 10

SCALE: 1/8" = 1'=0"

1 EXISTING OVERHEAD COILING DOOR TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING DOOR AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

2 EXISTING EXTERIOR DOOR AND FRAME TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING DOOR AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

3 EXISTING EXTERIOR WINDOW TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING WINDOW AND PREPARE OPENING FOR NEW

COMPONENT TO BE INSTALLED AS PER SCHEDULE.

4 EXISTING EXTERIOR LOUVER TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING LOUVER AND PREPARE OPENING TO BE FILLED AS

PER STRUCTURAL DETAILS.

5 EXISTING INTERIOR DOOR AND FRAME TO BE REMOVED.

6 INCREASE ROUGH OPENING SIZE TO ACCOMODATE A NEW PAIR 3-0 DOORS.

7 EXISTING OVERHEAD DOOR TO REMAIN IN PLACE.

8 EXISTING WINDOW TO REMAIN IN PLACE .

9 EXISTING EXTERIOR DOOR TO REMAIN IN PLACE.

10 EXISTING GLASS WALL TO BE REMOVED. REMOVE ALL FASTENERS AND BRACKETS IN PREPARATION TO INSTALL A NEW METAL STUD WALL AS PER PLANS.

11 EXISTING WALL AND WALL MOUNTED ITEMS TO BE REMOVED. VERIFY DIMENSIONS ON SITE.

12 EXISTING VIEWING WINDOW INTO RACQUET BALL COURT TO BE REMOVED.

13 EXISTING RACQUET BALL FLOORING TO BE REMOVED TO CONCRETE SLAB. PREPARE CONCRETE SLAB TO RECEIVE NEW FLOORING AS PER FINISH SCHEDULE.

14 EXISTING RACQUET BALL HARD CEILING TO BE REMOVED. RE: MEP DRAWINGS FOR ADDITIONAL INFORMATION.

15 NEW DOOR OPENING FOR NEW ACCESS DOOR TO RACQUET BALL COURT.

16 DIMENSION TO BE VERIFIED IN FIELD. APPROXIMATE BASED ON EXISTING DOCUMENTS.

17 EXISTING SUSPENDED ACCOUSTICAL CEILING SYSTEM TO BE REMOVED.. RE:MEP FOR ADDITIONAL INFORMATION.

18 EXISTING FLOORING TO BE REMOVED TO CONCRETE SLAB. PREPARE EXISTING SLAB FOR NEW FLOORING AS PER FINISH SCHEDULE.

19 EXISTING WALL PADDING TO BE REMOVED.

20 EXISTING MECHANICAL MEZZANINE ABOVE THIS AREA TO BE REMOVED AS PER SHEET AD108 (DECKING ONLY - STRUCTURAL MEMBERS TO REMAIN IN PLACE).

21 EXISTING LADDER TO MEZZANINE TO BE REMOVED WITH ALL COMPONENTS, INCLUDING BUT NOT LIMITED TO FASTENERS, BRACKETS, ETC.. REPAIR WALL, PATCH HOLES, REPAIR FLOORING AND REFINISH WALL AND FLOOR TO MATCH ADJACENT.

22 EXISTING ELECTRICAL CLOSET TO REMAIN IN PLACE. PROTECT DURING DEMOLITION.

23 EXISTING FLOORING DECK TO BE REMOVED. JOIST TO REMAIN IN PLACE.

24 REMOVE ALL DEBRIS LEFT OUT FROM MECHANICAL AND ELECTRICAL DEMOLITION WORK LEFT BEHIND INCLUDING BUT NOT LIMITED TO FASTENERS, HANGERS, METAL PANS, ETC.

25 REMOVE EXISTING ACCESS LADDER AND ALL ASSOCIATED HARDWARE. PATCH HOLES AND REPAINT WALLS AS NEEDED. PATCH AND CLEAN UP FLOOR TO

MATCH EXISTING.

26 EXISTING METAL CAGE TO BE REMOVED. PATCH ALL HOLES, AND REPAIR ANY OTHER DAMAGES AROUND THE WINDOW OPENING TO MATCH ADJACENT

WALLS.

27 EXISTING FAN IN CAGE TO BE REMOVED. REMOVE ALL COMPONENTS ASSOCIATED WITH EXISTING FAN INCLUDING THE CAGE AND PREPARE OPENING TO BE FILLED AS PER STRUCTURAL DETAILS. RE: MECHANICAL DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION.

28 REMOVE EXISTING VINYL FLOORING AND PREPARE SUBSTRATE FOR INSTALLATION OF NEW VINYL FLOORING.

29 SAW CUT BRICK BELOW THE EXISTING WINDOW TO EXTEND THE EXISTING OPENING TO THE FLOOR, CLEAN AND PREPARE TO RECEIVE NEW BLOCK NEW HM

DOOR AND FRAME.

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/3

/2

9/3/2026

W

2Q R

BA

1_

Pl an s-

A. COORDINATE ALL DEMOLITION AND PHASING EFFORTS WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). EVERY EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF OCCUPANT'S OPERATIONS. EXCESSIVE NOISE OR VIBRATION SHALL BE PRE-APPROVED AND COORDINATED WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R). IN ALL CASES, PROVISIONS SHALL BE MADE FOR

USER’S SAFETY.

B. COORDINATE ANY DISRUPTION OF UTILITY SERVICES WITH THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND AS SPECIFIED.

C. CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHIN THE EXISTING BUILDING WHICH OFFER A ONE-HOUR ENCLOSURE TO ISOLATE ANY DEMOLITION/CONSTRUCTION WORK FROM THE GENERAL

PUBLIC AND AS DEEMED NECESSARY BY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) AND CODE OFFICIAL HAVING JURISDICTION. COORDINATE LOCATIONS WITH THE CONTRACTING OFFICER

REPRESENTATIVE (C0R) AND MAINTAIN MEANS OF EGRESS THROUGHOUT THE WORK.

D. MAINTAIN A SECURE, WEATHER-TIGHT ENCLOSURE AT ALL TIMES.

E. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS AND NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE (C0R) OF ANY DISCREPANCIES.

F. REMOVE IN THEIR ENTIRETY ALL EXISTING WALLS, DOORS, MILLWORK, PLUMBING FIXTURES, CEILINGS, SOFFITS, WALL FIXTURES, AND OTHER ITEMS, AS REQUIRED TO EXECUTE THE

DEMOLITION/CONSTRUCTION WORK DESCRIBED BY THE DRAWINGS.

G. PROVIDE PROTECTION FOR ALL EXISTING BUILDING MATERIALS AND EQUIPMENT FROM DAMAGE DUE TO ANY DEMOLITION OR CONSTRUCTION-RELATED INCIDENT PERFORMED UNDER THIS CONTRACT.

H. REPAIR OR REPLACE ITEMS THAT ARE DAMAGED AS A RESULT OF DEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND/OR CONDITION.

I. NO EXISTING MATERIALS SHALL BE REUSED IN ANY INSTANCE. DISPOSE OF EXISTING DEMOLISHED MATERIALS AS PER SPECIFICATIONS.

J. VERIFY AND MAINTAIN THE LOCATION OF EXISTING POWER, COMMUNICATION AND DATA CABLES TO PREVENT INTERRUPTION OF THEIR SERVICE.

K. PATCH FLOOR, WALL AND CEILING PENETRATIONS RESULTING FROM REMOVAL OR RE-ROUTING OF NEW OR EXISTING PIPING, DUCTWORK, CONDUIT, AND OTHER ITEMS. FINISH AS REQUIRED FOR NEW OR

EXISTING ADJACENT SURFACES.

L. CAP ALL DISCONNECTED MECHANICAL PIPING LINES WITHIN THE WALL OR FLOOR. PATCH AND FINISH AS REQUIRED TO MATCH NEW OR EXISTING ADJACENT SURFACES.

M. SEE MECHANICAL AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

N. WHERE CMU WALLS ARE INDICATED TO BE REMOVED, PREPARE ADJACENT WALLS TO RECEIVE NEW PATCH/FINISH BY SAWCUTTING AND OR REMOVING CMU IN TOOTH-IN PATTERN BOTH SIDES OF DEMOLITION

FOR CONTRACTOR TO TOOTH-IN NEW CMU PATCHES AS NEEDED.

O. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS AND NOTES FOR FURTHER SEQUENCING AND SCOPE OF WORK.

P. COORDINATE WITH HAZARDOUS ABATEMENT SHEETS AND REPORT BEFORE ANY DEMOLITION TAKES PLACE.

DEMOLITION…

This is the start of the file's text. The full file is on GovTribe.