About this file

This document contains specifications for demountable partition systems required for the renovation of Building 1600 at Scott Air Force Base. The specifications provide the basis of design, acceptable manufacturers, panel descriptions, dimensions, finishes, and contact information for two demountable partition systems. System one requires laminate, acoustic, glass, and back painted glass panels to meet certain acoustic standards. System two requires laminate, frosted glass, and granite laminate panels. Both systems must integrate with selected systems furniture and be compatible with specified manufacturers. The renovation project is a firm-fixed-price contract with a magnitude between $100-250 million and a duration of 1260 calendar days. Proposals are due through the General Services Administration Contract Opportunities website and the selected contractor must have active SAM registration.

View the file

Other files for this federal contract opportunity

Other files attached to Scott AFB B1600 Renovation, newest first.
File Type Posted
W912QR20R0087-0005.pdf PDF
W912QR20R0087_Specs-0004.pdf PDF
W912QR20R0087_Plans-0004.pdf PDF
W912QR20R0087_Specs-0003.pdf PDF
W912QR20R0087_Plans-0003.pdf PDF
W912QR20R0087-0002.pdf PDF
W912QR20R0087_Specs-0001.pdf PDF
W912QR20R0087_Plans-0001.pdf PDF
W912QR20R0087_FFE-0001.pdf PDF
Site Visit Attendee List - 27 April 2021.pdf PDF
JA - District (SidePlate - Brand Name) - B1600 (Clean).pdf PDF
JA - District (Vindicator - Brand Name) - B1600 (Clean).pdf PDF
JA - SCO (HVAC Chillers - Brand Name) - B1600 (Clean).pdf PDF
JA - District (Monaco - Brand Name) - B1600 (Clean).pdf PDF
JA - SCO (Basis of Design) - B1600 (Clean).pdf PDF
JA - District (Security Cameras - Brand Name) - B1600 (Clean).pdf PDF
JA - SCO (HVAC DDC - Brand Name) - B1600 (Clean).pdf PDF
W912QR20R0087_Specs_ Vol1.3-0000.pdf PDF
W912QR20R0087_App_D3-Enviro-0000.pdf PDF
W912QR20R0087_Plans_Vol2.1A-0000.pdf PDF
W912QR20R0087_Plans_Vol2.1C-0000.pdf PDF
W912QR20R0087_Plans_Vol2.2C-0000.pdf PDF
W912QR20R0087_Plans_Vol2.3C-0000.pdf PDF
W912QR20R0087_Specs_ Vol1.5-0000.pdf PDF
W912QR20R0087_SID-0000.pdf PDF
W912QR20R0087_Plans_Vol2.1E-0000.pdf PDF
W912QR20R0087_Plans_Vol2.3A-0000.pdf PDF
W912QR20R0087_Specs_ Vol1.1-0000.pdf PDF
W912QR20R0087_Specs_ Vol1.2-0000.pdf PDF
W912QR20R0087_FFE-0000.pdf PDF
W912QR20R0087_Plans_Vol2.1B-0000.pdf PDF
W912QR20R0087_Plans_Vol2.1D-0000.pdf PDF
W912QR20R0087_Plans_Vol2.2A-0000.pdf PDF
W912QR20R0087_Plans_Vol2.2B-0000.pdf PDF
W912QR20R0087_Plans_Vol2.3B-0000.pdf PDF
W912QR20R0087_Specs_ Vol1.4-0000.pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project: Renovate Building 1600 ScottAFB Project # 10079513 Issue Date: Amendment 0003 (06/18/2021)

Item Specification

DP1 DEMOUNTABLE PARTITION QUANTITY: 0

BASIS OF DESIGN

Manufacturer: Teknion Model Name: Altos Landscape Model Number:

Description: - Horizontal mullion demountable wall system

- Wall divided into three horizontal sections.

- Top section: Bottom edge of top panel shall align with top of door frame. Height varies, see

RCP.

- Center section: panel shall be 4'-0"H.

- Bottom section: height as required, approximately 3'-0"

- Metal trim/mullions: Factory powder coat finish.

(Foundation Paint, color: Storm White 74/Q)

- Mullions to be visible only as necessary between glass.

- Reveal at panel connections to be 1/8" maximum

- Hinged solid wood door with full glass insert; all hardware shall be provided as indicated in construction drawings. Dealer responsible for coordinating final product with contractor.

- Wall heights shall be confirmed with ceiling plans for each location indicated.

POWER/DATA:

- Provide power/data connection capability from base or ceiling as indicated in construction drawings; NIPR and SIPR must have 3'-0" separation Amendment 0003*** Electrical cut outs to be factory cut per electrical drawings and as indicated in spec section 10 22 19. Electrical componentry to be supplied by the contractor.

***Amendment 003

ACOUSTICAL PERFORMANCE:

- Each wall assembly must meet acoustic performance indicated on STC Floor plans, AA120 series.

PANEL FACE TYPES:

Refer to IF110 series for location of panel face types

- Panel 1A: Laminate panel (Storm White XS/LW)

- Panel 1B: Acoustic Panel (LUUM, Heather Felt, Noil)

- Panel 1C: Transparent Glass

- Panel 1D: Back Painted Glass, non-magnetic writable (to match Storm White)

Acceptable Alternates:

1. Herman Miller, Maars Living Walls

2. Allsteel; Beyond Walls *Note: Must be compatible with systems furniture selected

Dimensions: Field Verify; Widths Vary x 0'-4"D x 9'-0"H Finish: See Item Description for Panel Finishes

W912QR20R0087-0003

Issue Date: Amendment 0003 (06/18/2021)

Item Specification

DP1 DEMOUNTABLE PARTITION QUANTITY: 0

Upholstery: See Item Description for Panel Finishes Notes: GSA Contract: GS-27F-0013V

CONTACT INFORMATION

Manufacturer: Contact:

Teknion Leonard Chapman 350 Fellowship Road, Suite 100 312-933-7366 Mt. Laurel, NJ 08054 leonard.chapman@teknion.com 877-835-6466

MATERIALS

Issue Date: Amendment 0003 (06/18/2021)

Item Specification

DP2 DEMOUNTABLE PARTITION QUANTITY: 0

BASIS OF DESIGN

Manufacturer: Teknion Model Name: Altos Landscape Model Number:

Description: - Horizontal mullion demountable wall system

- Wall divided into three horizontal sections.

- Top section: Bottom edge of top panel shall align with top of door frame. Height varies, see

RCP.

- Center section: panel shall be 4'-0"H.

- Bottom section: height as required, approximately 3'-0"

- Metal trim/mullions: Factory powder coat finish.

(Foundation Paint, color: Storm White 74/Q)

- Mullions to be visible only as necessary between glass.

- Reveal at panel connections to be 1/8" maximum

- Wall heights shall be confirmed with ceiling plans for each location indicated.

POWER/DATA:

- Provide power connection capability from base or ceiling as indicated in construction drawings Amendment 0003*** Electrical cut outs to be factory cut per electrical drawings and as indicated in spec section 10 22 19. Electrical componentry to be supplied by the contractor.

***Amendment 003

ACOUSTICAL PERFORMANCE:

- Each wall assembly must meet acoustic performance indicated on STC Floor plans, AA120 series.

PANEL FACE TYPES:

Refer to IF110 series for location of panel face types

- Panel 2A: Laminate panel (Granite LY)

- Panel 2B: Frosted Glass (50% Opacity)

Acceptable Alternates:

1. Herman Miller, Maars Living Walls

2. Allsteel; Beyond Walls *Note: Must be compatible with systems furniture selected

Dimensions: Field Verify; Widths Vary x 0'-4"D x 9'-0"H Finish: See Item Description for Panel Finishes Upholstery: See Item Description for Panel Finishes Notes: GSA Contract: GS-27F-0013V

Issue Date: Amendment 0003 (06/18/2021)

Item Specification

DP2 DEMOUNTABLE PARTITION QUANTITY: 0

CONTACT INFORMATION

Manufacturer: Contact:

Teknion Leonard Chapman 350 Fellowship Road, Suite 100 312-933-7366 Mt. Laurel, NJ 08054 leonard.chapman@teknion.com 877-835-6466