08 Electrical
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VFD
M
M
S
RACEWAY SYMBOLS
SURFACE MOUNTED CONDUIT
JUNCTION BOX - CEILING MOUNTED
CONCEALED CONDUIT IN CEILING OR WALL
WIREWAY, SIZE AND TYPE
AS INDICATED ON DRAWINGS
CABLE TRAY, SIZE AND TYPE
AS INDICATED ON DRAWINGS
JUNCTION BOX - WALL MOUNTED
J
J
RECEPTACLE SYMBOLS
DUPLEX RECEPTACLE TEXT INDICATES MOUNTING HEIGHT
CEILING MOUNTED DOUBLE DUPLEX RECEPTACLE
SIMPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
SPECIAL PURPOSE CONNECTION, SEE EQUIPMENT
WIRING SCHEDULE
CEILING MOUNTED DUPLEX RECEPTACLE
ABOVE COUNTER DUPLEX RECEPTACLE
C
F FLOOR BOX
C
60"
RECEPTACLE NOTATIONS:
DENOTES WEATHER PROOF OUTLETSWP
DENOTES GROUND FAULT INTERRUPTER OUTLETSGFCI
DENOTES ELECTRIC WATER COOLER OUTLETSEWC
SERVICE & DISTRIBUTION SYMBOLS
NEW PANELBOARD
EQUIPMENT GROUND BUSEGB
EXISTING PANELBOARD
MOTOR & EQUIPMENT CONNECTION
SYMBOLS
1 PHASE MOTOR CONNECTION
EQUIPMENT CONNECTION
3 PHASE MOTOR CONNECTION
COMBINATION MAGNETIC MOTOR CONTROLLER
MANUAL MOTOR CONTROLLER (3 PHASE)
VARIABLE FREQUENCY MOTOR CONTROLLER
MAGNETIC MOTOR CONTROLLER
NON-FUSED DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
DOUBLE THROW SWITCH
MOTOR RATED SWITCH
MOTOR RATED STARTER WITH OVERLOADS
GENERAL SYMBOLS
KEYED NOTE, USED TO DESCRIBE ADDITIONAL
INFORMATION OF WORK REQUIRED, SPECIFIC TO
THE SHEET AND/OR DETAIL IT IS SHOWN WITH.
DETAIL NUMBER / SHEET NUMBER#/E-###
9.###
LINE TYPE KEY
EXISTING TO BE REMOVED BY THIS
CONTRACTOR (DARK DASHED LINE)
EXISTING TO REMAIN WORK
(THIN SOLID LINE)
NEW WORK BY THIS CONTRACTOR
(DARK SOLID LINE)
ONE-LINE EQUIPMENT ENCLOSURE
PANEL DIVISION LINES
SITE UNDERGROUND ELECTRICE
SWITCHES, FOR MULTI-LEVEL SWITCHING. REFER TO FLOOR
PLANS AND FIXTURE SCHEDULE FOR EXACT CONTROL
INTENT.
SINGLE POLE SWITCH
LUMINAIRE CONTROL SYMBOLS
OCCUPANCY SENSOR CEILING MOUNT
(X REPRESENTS SCHEDULE DESIGNATION)
DAYLIGHT SENSOR , SEE OCCUPANCY SENSOR SCHEDULE
LUMINAIRE SYMBOLS
RECESSED LUMINAIRE
RECESSED TROFFER
RECESSED LINEAR
WALL MOUNTED EXIT SIGN
CEILING MOUNTED EXIT SIGN
PENDANT ROUND LUMINAIRE
OS X
DS
ARROW DENOTES EXIT SIGN CHEVRON
EMERGENCY BATTERY UNIT
SWITCH NOTATIONS:
3 DENOTES 3-WAY SWITCH
4 DENOTES 4-WAY SWITCH
D DENOTES WALL BOX DIMMER SWITCH
T DENOTES TIMER SWITCH
OSX DENOTES OCCUPANCY SENSOR
(X REPRESENTS SCHEDULE DESIGNATION)
B DENOTES MOMENTARY CONTACT BUTTON FOR BLUE
LIGHT SYSTEM
EMERGENCY SHADING MODIFIER
PENDANT INDUSTRIAL
WALL BRACKET
A1 1Ra
LUMINAIRE TYPE
LUMINAIRE CIRCUITRY & CONTROL KEY:
LOWER CASE LETTER INDICATES SWITCHLEG CONTROL
"R" INDICATES LIGHTING CONTROL PANEL
REFER TO LIGHTING CONTROL PANEL SCHEDULE
NUMBER INDICATES BRANCH PANEL CIRCUIT NUMBER
SURFACE COVE STRIP
SITE SYMBOLS
TRANS
ELECTRIC TRANSFORMER
DEMOLITION GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
THE INFORMATION SHOWN IS BASED ON EXISTING
DRAWINGS AND SITE OBSERVATIONS TO ASSIST
CONTRACTOR IN BIDDING. THE ELECTRICAL DRAWINGS
INDICATE EXISTING ELECTRICAL ITEMS TO BE REMOVED.
THE DRAWINGS ARE INTENDED TO INDICATE THE SCOPE
OF WORK REQUIRED AND DO NOT INDICATE EVERY BOX,
CONDUIT, OR WIRE THAT MUST BE REMOVED. THE
CONTRACTOR SHALL VISIT THE SITE PRIOR TO
SUBMITTING A BID AND VERIFY EXISTING CONDITIONS.
REFER TO SPECIFICATION SECTION 26 05 02 FOR
ADDITIONAL REQUIREMENTS.
DASHED WALLS ON THE FLOOR PLANS INDICATE EXISTING
WALLS BEING DEMOLISHED. DO NOT RELY ON
ELECTRICAL DRAWINGS TO DETERMINE EXTENT OF
GENERAL CONSTRUCTION DEMOLITION. REFER TO THE
ARCHITECTURAL DEMOLITION PLANS FOR THE EXACT
EXTENT OF WORK REQUIRED BY THIS PROJECT. REMOVE
ALL DEVICES ON DASHED WALLS NOT SHOWN ON THE
CONTRACT DRAWINGS. REFER TO DEMOLITION
DRAWINGS OF OTHER TRADES. WHERE MOTORS,
CONTROL PANELS, AND OTHER LOADS OR APPARATUS
THAT HAVE ELECTRICAL CONNECTIONS ARE BEING
REMOVED, INCLUDE DISCONNECTION AND REMOVAL OF
ALL ASSOCIATED CONDUIT, WIRING, ETC.
ELECTRICAL ITEMS (i.e., LIGHTING FIXTURES, PANELBOARDS, DISCONNECTS, MOTOR CONTROLLERS , ETC.) REMOVED AND NOT RELOCATED REMAIN THE
PROPERTY OF THE OWNER AND SHALL BE TURNED OVER
TO THE OWNER, IN A STORAGE AREA TO BE DESIGNATED
BY THE OWNER. EQUIPMENT BEING REMOVED SHALL BE
HANDLED SO AS NOT TO FURTHER REDUCE ITS VALUE TO
THE OWNER. THE CONTRACTOR SHALL DISPOSE OF
MATERIAL THE OWNER DOES NOT WANT TO REUSE OR
RETAIN FOR MAINTENANCE PURPOSES.
WHERE LIGHTS, SWITCHES, RECEPTACLES, ETC., ARE
BEING REMOVED ALL ASSOCIATED CONDUIT AND WIRE
BACK TO THE PANELBOARD OR FEEDER JUNCTION BOX
SERVING THE DEVICE SHALL ALSO BE REMOVED, UNLESS
THE CONDUIT CAN BE REUSED FOR NEW CONDUCTORS.
THE CONTRACTOR SHALL DISPOSE OF MATERIAL THE
OWNER DOES NOT WANT TO REUSE OR RETAIN FOR
MAINTENANCE PURPOSES.
ALL BOXES THAT REMAIN IN PLACE IN EXISTING MASONRY
WALLS THAT ARE TO REMAIN SHALL BE PROVIDED WITH A
BLANK COVERPLATE. REFER TO SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS ASSOCIATED WITH TYPE AND
ATTACHMENT.
ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE
BEING REMOVED. WHERE CONDUIT IS IN THE CONCRETE
SLAB, CUT OFF FLUSH, PULL OUT WIRE, AND PLUG.
WHERE CONDUIT IS RUN EXPOSED, ALL ASSOCIATED
CLAMPS, SUPPORTS, HANGERS, ETC., SHALL ALSO BE
REMOVED. CONDUIT CONCEALED IN WALL
CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT
AFFECTED BY OTHER CONSTRUCTION.
THIS CONTRACTOR SHALL COORDINATE ALL HIS WORK,
INCLUDING PHASING WITH OTHER CONTRACTORS AT THE
JOB SITE BEFORE REMOVING EXISTING ELECTRICAL AND
INSTALLING NEW ITEMS.
EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED
IN PLACE. RELOCATED EXISTING CONDUIT SHALL NOT BE
ALLOWED. BONDING CONDUCTORS SHALL BE INSTALLED
IN ALL REUSED CONDUIT TO ASSURE PROPER GROUND
PATH.
MAINTAIN CIRCUIT CONTINUITY OF DEVICES LOCATED
OUTSIDE OF CONSTRUCTION AREA. DEVICE AND
EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY
REQUIRE THE INSTALLATION OF A JUNCTION BOX TO
RECONNECT CIRCUITS THAT REMAIN IN OPERATION.
EXTEND CONDUIT AND WIRING AS REQUIRED TO MAINTAIN
POWER TO REMAINING EQUIPMENT.
BALLASTS MANUFACTURED PRIOR TO 1980 CONTAIN PCBs
AND SHALL BE DISPOSED OF IN ACCORDANCE WITH
SPECIFICATIONS.
HID AND FLUORESCENT LAMPS CONTAIN MERCURY AND
SHALL BE DISPOSED OF IN ACCORDANCE WITH
SPECIFICATIONS.
CONTRACTOR SHALL REMOVE AND INSTALL ALL CEILING
TILES AS REQUIRED FOR THE EXECUTION OF ELECTRICAL
WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF
CONSTRUCTION. CONTRACTOR SHALL REPLACE CEILING
TILES WITH IDENTICAL MATERIAL WHERE DAMAGED BY
THIS CONTRACTOR.
PROVIDE REVISED TYPED CIRCUIT DIRECTORY IN
PANELBOARDS THAT HAVE CIRCUITS REMOVED OR
ADDED CIRCUITS.
REMOVE EXPOSED ABANDONED CONDUIT, INCLUDING
ABANDONED CONDUIT ABOVE ACCESSIBLE CEILING
FINISHES. CUT RACEWAY FLUSH WITH WALLS AND
FLOORS, PATCH SURFACES TO MATCH EXISTING. REMOVE
ALL ASSOCIATED CLAMPS, HANGERS, SUPPORTS, ETC.
ASSOCIATED WITH RACEWAY REMOVAL.
DISCONNECT AND REMOVE ABANDONED LUMINAIRES,
INCLUDING BRACKETS, STEMS, HANGERS, AND OTHER
ACCESSORIES.
DISCONNECT AND REMOVED ELECTRICAL DEVICES AND
EQUIPMENT SERVING UTILIZATION EQUIPMENT THAT HAS
BEEN REMOVED.
ALL ELECTRICAL CONNECTIONS FOR MECHANICAL
DEVICES AND/OR EQUIPMENT SHALL BE DEMOLISHED
UNLESS NOTED OTHERWISE. CONNECTIONS ARE NOT
SHOWN ON PLAN. COORDINATE DEMOLITION WITH
MECHANICAL DEMOLITION CONTRACTOR.
GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
SEE SHEET E-001 FOR SYMBOLS AND ABBREVIATIONS.
SEE SHEET E-601 FOR LIGHT FIXTURE SCHEDULE.
SEE SHEET E-602 FOR EQUIPMENT CONNECTION
SCHEDULE.
SEE SHEETS E-603 FOR PANEL SCHEDULES.
SEE SHEET E-701 DRAWING FOR ONE LINE POWER
DISTRIBUTION DIAGRAMS.
ELECTRICAL DEVICES SHOWN AS THIN LINE TYPE ARE
EXISTING TO REMAIN AND SHALL BE RE-FED AS
INDICATED.
ALL EMEGENCY LIGHTING (SHOWN SHADED) SHALL BE
FED FROM INVERTER 'INV' UNLESS NOTED OTHERWISE.
ALL EXIT LIGHTS ON THIS PROJECT SHALL BE WIRED TO
CIRCUIT INV-1 UNLESS NOTED OTHERWISE.
ALL EMERGENCY LIGHTING SHALL BE #10AWG OR
LARGER.
ALL EMERGENCY UNIT EQUIPMENT OR EBU'S SHALL BE ON
THE SAME BRANCH CIRCUIT AS THAT SERVING THE
NORMAL OR EMERGENCY LIGHTING IN THE AREA
CONNECTED AHEAD OF ANY LOCAL SWITCHES OR
CONTROLS, PER NEC. 700.12(F).
ALL CEILING MOUNTED OCCUPANCY SENSORS SHALL BE
WIRED IN SERIES WITH ROOM LIGHT SWITCHES.
EC SHALL ALLOW TIME AND EFFORT FOR ALL OCCUPANCY
SENSOR FINE TUNING AND CALIBRATION.
COORDINATE LOCATION OF CEILING MOUNTED
OCCUPANCY SENSORS WITH HVAC CEILING DIFFUSERS.
DO NO INSTALL SENSOR WITHIN 3'-0" OF DIFFUSER.
ALL CEILING AND CORNER MOUNTED OCCUPANCY
SENSORS SHALL HAVE AN AUXILIARY NORMALLY OPEN
CONTACT TO TIE INTO THE BUILDING AUTOMATION
SYSTEM FOR INDICATION OF THE SPACE BEING OCCUPIED
OR UNOCCUPIED. THE CONTACT SHOULD FAIL CLOSED
FOR OCCUPIED MODE. IF MULTIPLE OCCUPANCY
SENSORS ARE USED FOR A SINGLE HVAC ZONE, THEY
SHALL BE DAISY CHAINED FOR A SINGLE ZONE BY THE
CONTROL CONTACTOR. THIS WORK SHALL BE
COORDINATED WITH HVAC CONTRACTOR IN FIELD.
COORDINATE EXACT LOCATIONS OF LIGHT FIXTURES
WITH ARCHITECTURAL REFLECTED CEILING PLANS.
COORDINATE LIGHT FIXTURE INSTALLATION WITH
DUCTWORK AND PIPING OF OTHER TRADES.
CONTRACTOR TO NOTIFY A/E IF CONFLICT EXISTS.
IN MECHANICAL ROOMS, COORDINATE EXACT PLACEMENT
OF LIGHT FIXTURES WITH DUCTWORK AND PIPING OF
OTHER TRADES. LOCATIONS SHOWN ON THIS PLAN ARE
BASED ON THE CURRENT DESIGN AND MAY REQUIRE
ADJUSTMENT DURING CONSTRUCTION. EC IS
RESPONSIBLE FOR COORDINATION EFFORT WITH OTHER
TRADES TO AVOID ANY AND ALL CONFLICTS.
ELECTRICAL CONTRACTOR SHALL REFER TO T-SERIES
SET OF DOCUMENTS INCLUDED IN THIS BID PACKAGE FOR
ALL LOW-VOLTAGE WORK ASSOCIATED WITH THIS
PROJECT. EC SHALL INCLUDE IN THIS BID ALL LABOR AND
MATERIALS REQUIRED FOR THE COMPLETE BOX AND
RACEWAY SYSTEMS FOR BOTH ACTIVE AND FUTURE
CABLES. ALL CABLE TRAYS, CONDUITS, BOXES AND
OUTLETS REQUIRED FOR LOW-VOLTAGE SYSTEM
INSTALLATION SHALL BE COORDINATED WITH T-SERIES
BID DOCUMENTS AND VERIFIED IN FIELD WITH SPECIFIC
LOW-VOLTAGE CONTRACTOR PRIOR TO ROUGH-IN.
SCIF GENERAL NOTES:
1. THE VAULT AREA IS CONSIDERED A SENSITIVE COMPARTMENTED
INFORMATION FACILITY. ALL NEW CONSTRUCTION AND RENOVATION TO THE
AREA INCLUDING WALL CONSTRUCTION, FIRE PROTECTION/DETECTION,
MECHANICAL/HVAC, ELECTRICAL, AND TECHNOLOGY SYSTEMS MUST
COMPLY WITH THE REQUIREMENTS PROVIDED IN UNIFIED FACILITY CRITERIA
4-010-05 SENSITIVE COMPARTMENTED INFORMATION FACILITY PLANNING,
DESIGN, AND CONSTRUCTION WITH CHANGE 1, 1 OCTOBER 2013, AND
REFERENCED IC TECH SPEC FOR ICD/ICS 705 TECHNICAL SPECIFICATIONS
FOR CONSTRUCTION AND MANAGEMENT OF SENSITIVE COMPARTMENTED
INFORMATION FACILITIES, VERSION 1.2, DATED 23 APRIL 2012.
2. CONSTRUCTION, GENERAL: UFC 4-010-05 REQUIREMENTS HAVE BEEN
INCORPORATED INTO THE DESIGN DRAWINGS AND SPECIFICATIONS.
CHANGES TO THE SCOPE OF WORK PROVIDED IN THE CONTRACT
DOCUMENTS MAY INVALIDATE THE APPROVALS RECEIVED FOR THIS
CONSTRUCTION, AND COULD RESULT IN THE REMOVAL AND
RECONSTRUCTION OF FINISHED WORK. ANY PROPOSED DEVIATIONS FROM
THE CONTRACT DOCUMENTS MUST BE FULLY REVIEWED AND APPROVED BY
THE COR PRIOR TO IMPLEMENTATION.
3. ALL CONSTRUCTION MUST BE DONE IN SUCH A MANNER AS TO PROVIDE
VISUAL EVIDENCE OF UNAUTHORIZED PENETRATION. CONSTRUCTION MUST
BE COMPLETED IN A MANNER TO PROVIDE THE REQUIRED STC RATINGS FOR
SOUND CONTROL AT THE WALLS IDENTIFIED. THROUGH-WALL
PENETRATIONS OF PIPE, CONDUIT, AND DUCTWORK REQUIRE SPECIAL
CONSTRUCTION AND INSPECTION PROVISIONS WHICH HAVE BEEN
INCORPORATED INTO THE CONTRACT DOCUMENTS.
4. THE CONTRACTOR SHALL SUBMIT A LIST OF ALL MATERIALS USED IN THE
CONSTRUCTION OF THE VAULT AREA, INCLUDING DIMENSIONAL EXTENTS OF
THE USE AND LOCATION(S) WHERE USED IN THE VAULT. THIS LIST SHALL BE
KEPT UP TO DATE DURING THE COURSE OF CONSTRUCTION AND SUBMITTED
TO THE COR AS PART OF THE CLOSE-OUT REQUIREMENTS AT THE END OF
CONSTRUCTION.
5. PHOTOGRAPHY REQUIREMENTS: THE CONTRACTOR IS NOT ALLOWED TO
HAVE PHOTOGRAPHIC OR RECORDING DEVICES IN THE VAULT AREA. 115 FW
CCZ PERSONNEL WILL BE TAKING PICTURES OF ON-GOING CONSTRUCTION
IN ORDER TO DOCUMENT THAT ALL SECURITY MEASURES ARE BEING MET.
THE COR SHALL BE NOTIFIED AT LEAST ONE WORKING DAY PRIOR TO KEY
CONSTRUCTION MILESTONES. KEY CONSTRUCTION MILESTONES INCLUDE
BUT ARE NOT LIMITED TO: WALL CONSTRUCTION, INCLUDING EACH OF
MULTIPLE LAYERS OF GYPSUM BOARD, FINISHING OF PENETRATIONS,
NON-CONDUCTIVE BREAKS OF PENETRATIONS, AND SOUND BATT
INSULATION INSTALLATIONS.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
5/ 2/
1:
:1
AM
C :\R ev it
Lo ca l\3
-1
9.
-E
-C en tra l-2
7_ m rf.
rv t
W
IS
C O
N
SI
N A
IR
N
AT
IO
N
AL
G U
AR
D
TR
U
AX
F
IE
LD
A N
G B
M
AD
IS
O
N , W
I
AD
AL
B
E-001
NOTES, SYMBOLS &
ABBREVIATIONS
XGFG132020ANG NO.:
3141300-141489.01
MRF
ARG
May 4, 2017
JRH/MRF
ELECTRICAL ABBREVIATIONS
3R NEMA 3R RATING
4X NEMA 4X RATING
A AMPERES
A/E ARCHITECT / ENGINEER
AAC ABOVE ACCESSIBLE CEILING
ACCU AIR COOLED CONDENSING UNIT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
ALT ALTERNATE
APE AIRCRAFT PROCESS EQUIPMENT
ATS AUTOMATIC TRANSFER SWITCH
BLDG BUILDING
BRKR BREAKER
C CONDUIT
C.O.R. CONTRACTING OFFICER REPRESENTATIVE
CB CIRCUIT BREAKER
CF CIRCULATION FAN
CH CHILLER
CHWP CHILLED WATER PUMP
CKT CIRCUIT
CP CIRCULATION PUMP
CRAC COMPUTER ROOM AIR CONDITIONER
CRP CONDENSATION RETURN
CT COOLING TOWER
CUH CABINET UNIT HEATER
DC DROP CORD
DDC DIGITAL CONTROL PANEL
DH DUCT HEATER
DISC DISCONNECT
DO DOOR OPERATOR
DWG DRAWING
E/O ELECTRICAL-TO-OPTICAL CONVERTER
EC ELECTRICAL CONTRACTOR
ECB ENCLOSED CIRCUIT BREAKER
EF EXHAUST FAN
EM EMERGENCY
EMT ELECTRICAL METALLIC TUBING
ERL EXISTING TO BE RELOCATED
ERLD EXISTING RELOCATED
ES EQUIPMENT SUPPLIER
ETR EXISTING TO REMAIN
EWC ELECTRICAL WATER COOLER
EWH ELECTRICAL WATER HEATER
F FUSED
FA FIRE ALARM
FAF FORCED AIR FURNACE
FCU FAN COIL UNIT
GC GENERAL CONTRACTOR
GD GARBAGE DISPOSAL
GFI GROUND FAULT INTERRUPTER
GND GROUND
GWH GAS WATER HEATER
HD HAND DRYER
HP HORSEPOWER
HVAC HEATING, VENTILATION, AIR CONDITIONING
HWB HOT WATER BOILER
HWP HOT WATER PUMP
IEWH INSTANTANEOUS ELECTRIC WATER HEATER
IH INFRARED HEATER
IMC INTERMEDIATE METALLIC CONDUIT
INV INVERTER
IWH INSTANTANEOUS WATER HEATER
J-BOX JUNCTION BOX
LBS POUNDS
LFS LIGHTING FIXTURE SCHEDULE
MAU MAKE-UP AIR UNIT
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MCC MOTOR CONTROL CENTER
MDF MAIN DISTRIBUTION FRAME
MDP MAIN DISTRIBUTION PANEL
MIN. MINIMUM
MNS MASS NOTIFICATION SYSTEM
MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
MW MICROWAVE
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NL/EL NIGHT LIGHT AND EMERGENCY LIGHT
NTS NOT TO SCALE
OC ON CENTER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
PH PHASE
PNL PANEL
PVC POLYVINYL CHLORIDE
RCP RADIANT CEILING PANEL
RECPT RECEPTACLE
REQ'D REQUIRED
RF RETURN FAN
RGS RIGID GALVANIZED STEEL CONDUIT
MAY ALSO BE REFERENCED AS RMC OR GRC
RMC RIGID METAL CONDUIT
RTU ROOF TOP UNIT
S/N SOLID NEUTRAL
SE SERVICE ENTRANCE
SEC-P SECURITY PANEL
SF SUPPLY FAN
SP SUMP PUMP
SS STAINLESS STEEL
SW SWITCH
SWBK SWITCH BANK
TBR TO BE REMOVED
TCP TEMPERATURE CONTROL PANEL
TFA TO FLOOR ABOVE
TFB TO FLOOR BELOW
TYP TYPICAL
UC UNIT COOLER
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UV UNIT VENTILATER
V VOLTS
VER VEHICLE EXHAUST REEL
VFD VARIABLE FREQUENCY DRIVE
VS VERSUS
W WATTS
WCC WATER COOLED CONDENSER
WCR WITHSTAND CURRENT RATING
WFE WELDING FUME EXTRACTOR
WH WATER HEATER
WL WET LOCATION LISTED
WP WEATHERPROOF
XFMR TRANSFORMER
XP EXPLOSION PROOF
05/04/17 TYPE B3
O S
OS
OS
OS
OS
OS
OS OS
OS
O S
O S
O S
OS OS
OS
OS
OS
OS
OS
O S
O S
O S
OS
O S
O S O
S
OS
OS
OS
OS
OS
OS
OS
JJ
J
J
J J
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
J
J
K
K
L
L
M
M
N
N
P
P
Q
Q
R
R
S
S
T
T
24 24
23 23
22 22
21 21
20 20
19 19
18 18
17 17
16 16
15 15
14 14
13 13
12 12
11 11
10 10
9 9
8 8
6 6
5 5
4 4
3 3
2 2
1 1
LECTURN
(6)
ETR
ALERT INDICATOR
BEACON
ALERT INDICATOR
BEACON
ETR
ERL
ERL
ERL
ERL
J
ERL
9.002
9.003
PANEL MAIN
BRIEFING
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
5/ 2/
1:
:3
AM
C :\R ev it
Lo ca l\3
-1
9.
-E
-C en tra l-2
7_ m rf.
rv t
W
IS
C O
N
SI
N A
IR
N
AT
IO
N
AL
G U
AR
D
TR
U
AX
F
IE
LD
A N
G B
M
AD
IS
O
N , W
I
AD
AL
B
ED101
FIRST FLOOR
DEMOLITION PLAN -
LIGHTING
XGFG132020ANG NO.:
3141300-141489.01
MRF
ARG
May 4, 2017
JRH/MRF
KEYED NOTES
9.002 CAREFULLY DISCONNECT AND REMOVE ALERT SCRAMBLE INDICATOR
RELAY BOX FOR RELOCATION TO NEW TELECOM ROOM.
9.003 EXISTING BACK BOXES SHALL REMAIN TO SERVE NEW LIGHTING
CONTROLS.
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"1 FIRST FLOOR DEMOLITION PLAN - LIGHTING
C
C
F
C
JJ
J
J
J J
C
C C
CC
A
A
B
B
C
C
D
D
E
E
F
F
G
G
J
J
K
K
L
L
M
M
N
N
P
P
Q
Q
R
R
S
S
T
T
24 24
23 23
22 22
21 21
20 20
19 19
18 18
17 17
16 16
15 15
14 14
13 13
12 12
11 11
10 10
9 9
8 8
6 6
5 5
4 4
3 3
2 2
1 1
PANEL LP1B
UPS
PANEL LP1A
PANEL LP1F
PANEL LP1G
FCU-1
EF-2
EWH-1B
EWH-1A ACCU-1
TV
BCU-1
ACCU-2
PANEL LP1D
PANEL LP1C PANEL MDP
CP-1
CUH
CUH
CUH CUH
CUHCUH
WP/GFCI
WP/GFCI
CUH
CUH
M
EXISTING
UTILITY
TRANS
9.001
ETRCUH
ATS
PANEL MAIN
BRIEFING
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
5/ 2/
1:
:5
AM
C :\R ev it
Lo ca l\3
-1
9.
-E
-C en tra l-2
7_ m rf.
rv t
W
IS
C O
N
SI
N A
IR
N
AT
IO
N
AL
G U
AR
D
TR
U
AX
F
IE
LD
A N
G B
M
AD
IS
O
N , W
I
AD
AL
B
ED131
FIRST FLOOR
DEMOLITION PLAN -
POWER
XGFG132020ANG NO.:
3141300-141489.01
MRF
ARG
May 4, 2017
JRH/MRF
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"1 FIRST FLOOR DEMOLITION PLAN - POWER
05/04/17 TYPE B3
KEYED NOTES
9.001 UTILITY WILL BE RESPONSIBLE FOR ALL DEMOLITION WORK ASSOCIATED
WITH EXISTING UTILITY TRANSFORMER, PAD AND SECONDARY UTILITY
FEEDERS.
OS2
OS1
OS1
OS3
OS2
OS2
OS2
OS1
OS1OS1 OS1OS1
OS1
OS1
OS1
OS1
OS2
OS2
OS1
OS1
OS1
OS1
OS6
OS1
OS1
OS1
OS2
OS2
OS2
OS2
OS3
OS3
OS3
DS
OS2
OS1
OS2
OS4
OS3
OS1 OS1 OS1 OS1
OS5
OS5
OS1
OS1
OS1
OS1
OS1
OS1
OS1
OS5
OS5
OS5
DS
OS1
OS1
OS6
OS6 OS6
OS6
OS4
OS6
OS4
OS4
OS4
OS1
OS2
DS DS DS DS
DS
OS2
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
J
J
K
K
L
L
M
M
N
N
P
P
Q
Q
R
R
S
S
T
T
24 24
23 23
22 22
21 21
20 20
19 19
18 18
17 17
16 16
15 15
13 13
12 12
11 11
10 10
9 9
8 8
6 6
5 5
4 4
3 3
2 2
1 1
INTEL VAULT
CLASSROOM111
INTEL
INTEL OIC
BRIEFING
ROOM 3
BRIEFING
ROOM 1
HALLWAY
BRIEFING
ROOM 2
BRIEFING
ROOM 4
LIBRARY
STORAGE
BREAK ROOM
MISSION
PLANNING
WEAPONS
ACMI
ISSO & SSR
COMM/
COMPUTER
STORAGE
LOBBY
VEST
MX DEBRIEF
SECURED
VEST
FLIGHT
COMMANDERS
OPEN OFFICE
PM/PSM
SECURE
VAULT
CORR
SIMULATOR
SUPPORT
OFFICE
ARMS NCOIC
VEST
ARMS
COPY ROOM
SOF
VEST
AFMT NCOIC
STORAGE
TRAINING
OFFICER
SCHEDULING
HALLWAY
AIRFIELD
MANAGEMENT
DIRECTOR OF
OPERATIONS
VEST
HALLWAY
HALLWAY
CONFERENCE
ROOM
STAN EVAL
OPERATIONS
CHIEF 151
CCA
OSS
COMMANDER
MEN'S
TOILET/
LOCKER
ROOM
AFE NCOIC
AIRCREW
FLIGHT
EQUIPMENT
AFE
SUPERINTENDENT,
FEO
NVG
AFE
INSPECTION
ROOM
STORAGE
JANITOR
WOMEN'S
TOILET/
LOCKER
ROOM
HALLWAY
VEST
KITCHEN/
VENDING
BREAK ROOM
MAIN
BRIEFING
ROOM
MECH
AFE
STORAGE
ELEC
COMM
D
D D
DD
X1 X1
D
D
OS
D
OS
X1 X1
X1
D
D D D D
D
D D D D
D
D
D
OS
D
D
DD
D
D
D
D
D
INTEL NCOIC
BL
BB
B
B B
B
B
B
B
B
B
B
B
B
B
B B
B B B B
BB
B
B B B B
B
B
B
B B B
BB
B B
BB
BB
B B
B
BB
B B B
BB
B B
B B
BB
B
B
B B
B B
B
B
B
B
B
B B
B
B B
B B
B B B
BB B B
BB
BL
BL
D1 D1 D1 D1
D1 D1 D1 D1
D
D D D
DD
D ab
D ab
BL BL
BL BL
D D ab ab
LP1X-5a LP1X-5a
LP1X-5aLP1X-5a
LP1X-5a
LP1X-5a LP1X-5a
LP1X-5a a,b a,b a,ba,b
LP1X-5b LP1X-5b LP1X-5b LP1X-5b
LP1X-5bLP1X-5bLP1X-5bLP1X-5b
BL
BL
BL
BL
BL
a,b,c
11a 11a 11b
11b 11a
11a
11a 11a 11b
11c 11c 11c
11c11c11c
D a cb
B
D ab
7a 7a 7a
7b7b a,b
BL
BL
F
F
BL
BLB
B
BLBOS
B B
BB
DD
ab a,b
7a
7a
7b 7b
7a
7b
BL
B
U b 5b a,b
5a 5a
5a 5a a
3c D
3b 3a
DD
3a3b
3c
7c
5c 5c
7c5c
5c5c
LP1X-5a 7a
LP1X-5bLP1X-5b
LP1X-5b 7b
LP1X-5a LP1X-5a
LP1X-5b 7b
LP1X-5b 7b a,b,c a,b,c a,b,c
BL
BL
BL
B B
B B
BL
D
3d 3d
B 9d
B 7d d a a b
B
B
1a
3a
B 3b
3a
3a
3b
3b
X1
X1 X1 d,f c,d,f 3c
3c 3d
3d
X1
DD
B
B
B
B
B
B
B
B 1e
B 3e
B 1e
B 3e
B 1e
D1 3e3e e
B
BB
B 3a
3a3a
3a b a
D 3b
D 3b
B
B
B
B
B
B
D
B
B f
3f
3f f
B
B
T
D1 D1
D1D1
C1 C1D1
UNSW.
D2 D2UNSW.
B B B
C
B
B B B B
B B B B
D
B
B
D2
D2
D2
D2
T
T
C1 C1
C1C1
DD
D1
D1 D1
D1 D1
D1D1
D D
UNSW.
B B
BB
3f
3g g
3f
3g
D i
3i 3i
3i3i f,g,h,ji,k
D
Da b a,b
3a 3a
3a3a
D
D
D
D
3b 3b
3b3b
B 3a
B 1a
B 3a
B 3a
D1
OS
C C
B 3b
B 1b
B 3b
D D
3h
3h
F1 F1
F
F
F
F
OS
9.101 (TYP.)
9.101 (TYP.)
F F
F
OA
OA
OA
OA
OA
OA
OA
OA
OA OA
OA
INV
PANEL LP1X
PANEL LP1B
PANEL LP1F
PANEL LP1G
PANEL LP1A
9.102
B
X1
9.103
F1 F1 F1 F1
F1 F1 F1
F1 F1 F1 F1
F1
F1
(TYP.)
9a 1a 1a 9a
1b 9b 1b
9a 1a 1a 9a
9b
3a3b
D D3b 3a
9.105 a,b a,b a,b a,b
9.105 (TYP.)
EBU
EBU
9.101
9.101
G
G1
G2
G3
H H
HHH
H H H
HH
9.106 (TYP.)
9.110 X1
3f
5f
5g
3g
3g
3g
G4 G4 G4 G5LP1X-7d
LP1X-7d LP1X-7d LP1X-7c
3d
D
G6 G6 LP1X-7c 3c
D1
D1 D1
D1
H1 H1 H1 H1
H1 H1 H1 H1
H1 H1
9.107 (TYP.)
3h 3h
3g3g3h
3h 3g 3g
3g3g
3j
3j
9.108
1j 1j
1j1j3j1j
1j 3j 1j 1j
D1
D1
D1
5a
5a
5a
D1 5a
D1 5a
D1 5a
D 5d
D 5d
D 5d
D3 6c
D 6b
D 6bD
6b
D 6b
D 6b D
6b
D 6b
D 6bD
6b
X1 X1
X1
3a 3a
LECTURN
J1
J1 J1 J1
J1 J1J1
J1
J1 J1 J1
J1
J
JJ
J
7e
7e 7e 7e
7e 7e7e
7e
7e 7e 7e
7e
7e 7e7e
7e
4a b c d e f
D
OS
F
F
F
9.101
9.101
9.103
9.1049.104
9.1049.104
9.104
X1
X1 9.111
9.112(TYP.)
U 3k U k
X1
X1
9.101(TYP.)
X1
X1
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
D1
D1
BL
BL
BL
B
BL
B
B
B
B
BB
B B
B
B
B B
B
B
B
B
9.114
9.115
9.116
B 3a
B
ETR
H1 1j
F2
9.117
D3 6c
D3 6c
ALL 120V NORMAL POWER
LIGHTING SHALL BE FED FROM
PANEL 'MAIN BRIEFING ROOM'
UNLESS NOTED OTHERWISE.
ALL 120V NORMAL
POWER LIGHTING SHALL
BE FED FROM PANEL
'LP1B' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER LIGHTING SHALL
BE FED FROM PANEL
'LP1B' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER LIGHTING SHALL
BE FED FROM PANEL
'LP1B' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER LIGHTING SHALL
BE FED FROM PANEL
'LP1G' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER LIGHTING SHALL
BE FED FROM PANEL
'LP1G' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER LIGHTING SHALL
BE FED FROM PANEL
'LP1A' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER LIGHTING SHALL
BE FED FROM PANEL
'LP1B' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER LIGHTING SHALL
BE FED FROM PANEL
'LP1A' UNLESS NOTED
OTHERWISE.
LP1X-3
LP1X-3
LP1X-5
LP1X-5
LP1X-5
3d
D
9.118 a,b
3 3
3 3
3 3 3
33 3 3
5 5
5 5
55 5
7 7
9.120 (TYP.)
ETR
VIA PT
VIA PT
VIA PT
K 7f
K 7f
K 7f
9.121 (TYP.)
D
D
11c
11c
D 11c
D 11c
D 11c
D 11c f
ERLD
LP1X-7f
OS
OS9.101
L
9.122
1b 1b
5 5
7 7 7
7 7
7 7
1b
5 5
7 7
9 9
13 13
9.106
X1
VIA PT
VIA PT VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PT
VIA PTVIA PT
9.101
9.101(TYP.)
D
9.123
D1 1a
D1 3j
D1 3j
D1 3j
3j D f,g,h,j
VIA PT
VIA PT
U 5b
9.120(TYP.)
E-101
FIGHTER
SQUADRON
COMMANDER
OPERATIONS
GROUP
COMMANDER
166C
STORAGE
166B
STORAGE
166A
STORAGE
WOMENS
ENTRY
AL
AL
AL
AL
AL
AL
J
ERLD
9.119
K
D
D
D
D
AL
AL
9.104
INVERTER
9.124
PANEL MAIN
BRIEFING
ALAL
VIA PT
X1
P
P
Q
Q
R
R
15 15
14 14
13 13
12 12
11 11
D
B B B
BB
B
B
7 7 7
AFE
INSPECTION
ROOM
U2
U2
U1
U2
U2
U1
U2
U1
U2
U2
U1 U2 U2 U2 U2 U2 U2 U1
7 7 7 7 7 7 7 7
79.120 (TYP.)
KEYED NOTES
9.101 MOUNT FIXTURE AT 8'-6" AFF MEASURED FROM BOTTOM OF FIXTURE.
9.102 MOUNT FIXTURE AT 10'-0" AFF MEASURED FROM BOTTOM OF FIXTURE.
TYPICAL FOR ALL TYPE "OA" FIXTURES SHOWN ON THIS PLAN.
9.103 SECURE AREA PERIMETER. COORDINATE WITH GENERAL CONTRACTOR.
MINIMIZE, CO-LOCATE, AND SEAL ALL SECURE AREA PENETRATIONS. SEE
DETAIL 1/E-501. CAULK AND SEAL ALL CONDUIT PENETRATIONS IN A
MANNER THAT MAINTAINS ROOM'S SOUND TRANSMISSION CLASS (STC)
RATING OF 55. ALL DEVICES/CONDUIT LOCATED ON THIS PERIMETER WALL
SHALL BE SURFACE MOUNTED. UTILIZE WIREMOLD 700 SERIES OR EQUAL
SURFACE MOUNTED RACEWAY.
9.104 DOTTED LINE INDICATES BOUNDARY OF SOUND ASSEMBLY GROUP 4 -
MINIMUM STC 55. CAULK AND SEAL ALL CONDUITS IN A MANNER THAT
MAINTAINS ROOM'S SOUND TRANSMISSION CLASS (STC) RATING OF 55.
9.105 MOUNT FIXTURE AT 12'-6" AFF MEASURED FROM BOTTOM OF FIXTURE.
9.106 MOUNT FIXTURE AT 8'-0" AFF MEASURED FROM BOTTOM OF FIXTURE.
9.107 MOUNT FIXTURE 2" BELOW SOUNDSCAPE BLADES MEASURED FROM
BOTTOM OF FIXTURE. FIXTURES SHALL BE MOUNTED BETWEEN
SOUNDSCAPE BLADES. COORDINATE EXACT LOCATION WITH RESPECTIVE
ARCHITECTURAL PLANS.
9.108 HIGH BAY OCCUPANCY SENSOR SHALL BE CORNER MOUNTED BELOW
SOUNDSCAPE BLADES TO ALLOW CLEAN VIEWING ANGLE.
9.110 MOUNT FIXTURE AT 7'-2" AFF MEASURED FROM BOTTOM OF FIXTURE.
9.111 MOUNT FIXTURE AT 10'-0" AFF MEASURED FROM BOTTOM OF FIXTURE.
9.112 MOUNT FIXTURE AT 7'-0" AFF MEASURED FROM BOTTOM OF FIXTURE.
9.114 BLUE LIGHT SYSTEM MASTER PUSHBUTTON STATION. REFER TO DETAIL
4/E-501 FOR ADDITIONAL INFORMATION.
9.115 MOUNT BLUE INDICATOR LIGHT SURFACE MOUNTED ON BOTTOM OF
STRUCTURAL JOIST. TYPICAL FOR ALL 'BL' LIGHT FIXTURES SHOWN ON THIS
PLAN LOCATED IN ROOMS WITH EXPOSED CEILINGS.
9.116 HIGH BAY OCCUPANCY SENSOR SHALL BE MOUNTED ON BOTTOM OF
STRUCTURAL JOISTS. TYPICAL FOR 'OS6' OCCUPANCY SENSORS SHOWN
ON THIS PLAN.
9.117 FIXTURE IS MOUNTED FROM EXPOSED CEILING IN LOBBY 101 LOCATED
ABOVE CEILING SHOWN IN COMM/COMPUTER STORAGE 107. REFER TO
KEYED NOTE 9.107 FOR ADDITIONAL INFORMATION.
9.118 SECURE AREA PERIMETER. COORDINATE WITH GENERAL CONTRACTOR.
MINIMIZE, CO-LOCATE, AND SEAL ALL SECURE AREA PENETRATIONS. SEE
DETAIL 1/E-501.
9.119 EXISTING RELOCATED ALERT SCRAMBLE INDICATOR RELAY BOX.
INTERCEPT EXISTING DEDICATED PHONE LINE IN OLD COMM ROOM AND
EXTEND TO NEW ALERT SCRAMBLE INDICATOR RELAY BOX LOCATION. THIS
WILL ALLOW FOR REMOTE ACTIVATION FROM BUILDING 402 VIA BUILDING
505. COORDINATE LOCATION OF EXISTING PHONE LINE WITH C.O.R.
9.120 ROUTE CONDUIT CONCEALED FROM FLUSH SWITCH BOX TO BOTTOM SIDE
OF CABINET, AND PROVIDE SURFACE MOUNTED FLEXIBLE METAL CONDUIT
FROM WALL PENETRATION TO LIGHT FIXTURE. COORDINATE EXACT
MOUNTING LOCATION OF UNDERCABINET LIGHTING WITH ARCHITECTURAL
SECTIONS AND ELEVATIONS.
9.121 COVE FIXTURE SHALL BE MOUNTING IN EXISTING COVE SLOT. REFER TO
LIGHT FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION.
9.122 FIXTURE SHALL BE INSTALLED IN ATTIC SPACE. MOUNT FIXTURE 2'-0"
BELOW ROOF DECK MEASURED FROM BOTTOM OF FIXTURE.
9.123 FIXTURE SHALL BE SURFACE MOUNTED AT TOP OF DISPLAY CASE. REFER
TO ARCHITECTURAL SECTIONS AND ELEVATIONS FOR ADDITIONAL
INFORMATION.
9.124 UTILIZE EXISTING BACK BOXES FOR INSTALLATION OF NEW LIGHTING
DIMMER SWITCHES.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
5/ 3/
2:
:4
PM
C :\R ev it
Lo ca l\3
-1
9.
-E
-C en tra l-2
7_ m rf.
rv t
W
IS
C O
N
SI
N A
IR
N
AT
IO
N
AL
G U
AR
D
TR
U
AX
F
IE
LD
A N
G B
M
AD
IS
O
N , W
I
AD
AL
B
E-101
FIRST FLOOR PLAN -
LIGHTING
XGFG132020ANG NO.:
3141300-141489.01
MRF
ARG
May 4, 2017
JRH/MRF
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"1 FIRST FLOOR PLAN - LIGHTING
PLAN
NORTH
TRUE
NORTH
1/4" = 1'-0"2 ENLARGED LIGHTING PLAN - AFE INSPECTION ROOM 159
F
F
C
C
C C
C C
C
C
M S
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
J
J
K
K
L
L
M
M
N
N
P
P
Q
Q
R
R
S
S
T
T
24 24
23 23
22 22
21 21
20 20
19 19
18 18
17 17
16 16
15 15
14 14
13 13
12 12
11 11
10 10
9 9
8 8
6 6
5 5
4 4
3 3
2 2
1 1
INTEL VAULT
CLASSROOM111
INTEL
INTEL OIC
INTEL NCOIC
BRIEFING
ROOM 3
BRIEFING
ROOM 1
HALLWAY
BRIEFING
ROOM 2
BRIEFING
ROOM 4
LIBRARY
STORAGE
BREAK ROOM
MISSION
PLANNING
WEAPONS
ACMI
ISSO & SSR
COMM/
COMPUTER
STORAGE
LOBBY
VEST
MX DEBRIEF
SECURED
VEST
FLIGHT
COMMANDERS
OPEN OFFICE
PM/PSM
SECURE
VAULT
CORR
SIMULATOR
ELEC
FIRE ALARM
SIMULATOR
SUPPORT
OFFICE
ARMS NCOIC
VEST
ARMS
COPY ROOM
SOF
VEST
AFMT NCOIC
STORAGE
TRAINING
OFFICER
SCHEDULING
HALLWAY
AIRFIELD
MANAGEMENT
DIRECTOR OF
OPERATIONS
FIGHTER
SQUADRON
COMMANDER
VEST
HALLWAY
HALLWAY
CONFERENCE
ROOM
STAN EVAL
OPERATIONS
CHIEF 151
CCA
OSS
COMMANDER
MEN'S
TOILET/
LOCKER
ROOM
AFE NCOIC
AIRCREW
FLIGHT
EQUIPMENT
AFE
SUPERINTENDENT,
FEO
NVG
AFE
INSPECTION
ROOM
STORAGE
JANITOR
WOMEN'S
TOILET/
LOCKER
ROOM
HALLWAY
VEST
KITCHEN/
VENDING
BREAK ROOM
MAIN
BRIEFING
ROOM
MECH
AFE
STORAGE
ELEC
COMM
TV
WP/GFCI
WP/GFCI
E-131
E-131
PANEL LP1A
CT CABINETGENERATOR PLUG
SIM 1 SIM 2
9.2019.201
GFCI GFCI
GFCIGFCI
GFCI GFCI
GFCI
WP/GFCI
WP/GFCI
WP/GFCI
WP/GFCI
M
VRF-W110
VRF-W109
VRF-W112VRF-W111
VRF-W105
VRF-W106
VRF-W100
VRF-W101
VRF-E118
VRF-E117
VRF-E122
VRF-E119
VRF-E109
VRF-E108
VRF-E107
VRF-E124
UTILITY
TRANS
VRF-W107
VRF-E120
VRF-W115
VRF-W114 VRF-W113
VRF-W103
VRF-E126
VRF-E116
VRF-E115 VRF-E123
VRF-E114
VRF-112
VRF-E113
VRF-E106 VRF-E104 VRF-E103
VRF-E111
VRF-E110 VRF-E101 VRF-E102
VRF-E125
VRF-W116
9.202
9.203
9.202
9.2039.203
9.2039.203
9.203
TVTV
TV
GFCI
EWC
VRF-W102
CRAC-1
CRAC-2
AHU-1
(ROOF)
AHU-2
(ROOF)
EF-1
(ROOF)
FC-2
ACCU-2
ACCU-4
ACCU-1A
ACCU-1B
GFCI
WP/GFCI
9.205
E
UTILITY PROVIDED
SECONDARY FEEDER
9.2129.207
9.207
9.207
9.207
9.207
9.207
9.207
9.207
9.2079.207
9.207
9.207
9.207
9.207
9.220
9.207
9.211
9.207
9.211
42" 74" 42" 74"
NEMA 6-30
9.208
GFCI
GFCI
GFCI
WP/GFCI
GFCI
44"
44"
44"
44"
GFCI
GD
9.209 9.210
VRF-W117
VRF-W108
VRF-105
VRF-E127
VRF-E100
VRF-E129
VRF-E128
VRF-W104
VRF-E121
BSB-6
BSB-5
BSB-4
BSB-2
BSB-1
BSB-3
CRAC-4
(ROOF)
FC-1
CUH-3
CUH-2
CUH-1
ETR
CUH
CUH-7
CUH-6
CUH-5
CUH-4
ALL 120V NORMAL POWER
DEVICES ARE ETR AND FED FROM
PANEL 'MAIN BRIEFING ROOM'
UNLESS NOTED OTHERWISE.
ALL 120V NORMAL
POWER DEVICES SHALL
BE FED FROM PANEL
'LP1B' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER DEVICES SHALL
BE FED FROM PANEL
'LP1B' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER DEVICES SHALL
BE FED FROM PANEL
'LP1B' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER DEVICES SHALL
BE FED FROM PANEL
'LP1G' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER DEVICES SHALL
BE FED FROM PANEL
'LP1G' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER DEVICES SHALL
BE FED FROM PANEL
'LP1A' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER DEVICES SHALL
BE FED FROM PANEL
'LP1B' UNLESS NOTED
OTHERWISE.
ALL 120V NORMAL
POWER DEVICES SHALL
BE FED FROM PANEL
'LP1A' UNLESS NOTED
OTHERWISE.
E-131
9.207
GFCI
42" 74" 42" 74"
42" 74"
42" 74"
42" 74"
42" 74"
42" 42" 42" 42"
42" 42" 42"
74"
74"
LP1F-4LP1F-2
GFCI
LP1F-46
LP1F-48
LP1F-44
74"
74"
9.207
9.207
9.207
44"GFCI
GFCI
44"
GFCI
DW
CLOCK
84"
GFCIGFCI
78"60"
TP
TP
9.214
9.216
9.215
P-7 P-6
166C
STORAGE
166B
STORAGE
166A
STORAGE
WOMENS
ENTRY
9.213
L5-30R
L5-30R
MW
MW
60"
60"
UH-3
VRF-E130
72"
84"
84"
LP1B-13
LP1B-15
LP1B-15
J9.217 72
J9.217 72
J9.217 38
J
9.217
LP1B-66,68
LP1B-66,68
LP1B-66,68
LP1B-66,68
LP1B-66,68
LP1B-66,68
17 17 70
LP1B-11
79 17 17 70 24
LP1B-33
LP1B-50,52
LP1B-50,52
LP1B-62,64
LP1B-62,64
LP1B-62,64
LP1B-62,64
LP1B-62,64
LP1B-62,64 LP1B-62,64
LP1B-62,64
LP1B-62,64
LP1B-11
LP1B-9
9 9
9.218
LP1B-44,46,48
LP1B-74
9.218
LP1B-20
LP1B20
16,18
LP1B-55
36 36
LP1A-32
LP1B-43,45,47
LP1B-49,51,53
LP1B-58,60
LP1B-58,60
LP1B-58,60 LP1B-58,60 LP1B-58,60
LP1B-58,60LP1B-58,60
LP1B-58,60LP1B-58,60
LP1B-58,60
OPERATIONS
GROUP
COMMANDER
LP1B-50,52
LP1B-50,52
14 LP1A-14
LP1A-12
LP1B-54,56
LP1B-54,56
LP1B-54,56
LP1B-54,56
LP1B-54,56
LP1A-9 LP1X-23
LP1X-23
LP1X-19
LP1X-21
LP1X-19
LP1X-19
LP1X-15
LP1X-17
LP1X-15
LP1X-17
LP1X-15
LP1B-54,56
LP1X-15 LP1X-13
LP1X-13
LP1X-13
LP1F-1,3
LP1F-1,3
LP1F-1,3
LP1F-1,3
LP1F-1,3
LP1F-1,3
LP1F-1,3
LP1F-1,3
37 37
37 39
39 39
LP1F-62
LP1F-64
21 21
LP1F-5,7
LP1F-5,7
23 23
25 25 27
272525
29 29 33 33
LP1F-5,7
33332929
LP1G-38
LP1F-5,7 LP1F-5,7
14 12
12 12
9.219 9.219
6 4
22 20
LP1F-5,7
9.219 9.219
LP1F-5,7
30 28
LP1F-35,37,39
LP1F-54
LP1F-5,7
LP1F-54
LP1F-5,7
LP1F-56
LP1F-54
LP1F-54
LP1F-5,7
151917
LP1F-9,11
LP1F-9,11
LP1F-48
LP1F-48
LP1F-48
LP1F-48
LP1F-50
LP1F-50
LP1F-50
LP1F-50
LP1F-22,24,26 LP1F-28,30,32
LP1F-34,36,38LP1F-19,21,23
9.207
2 4
LP1F-8
LP1F-8
LP1F-8
LP1F-6
LP1F-6
LP1F-6
10 10
LP1F-40,42
LP1F-31,33
LP1F-12
LP1F-18
LP1F-14
LP1F-16
60"
LP1X-2
LP1F-13,15,17
18 18
44" 44"
LP1F-58 LP1F-58
9.2019.201
9.222 9.222
WP/GFCI
GFCI
GFCI
UH-4
LP1G-32
UTILITY METER
9.224
9.225
9.207
PANEL MAIN
BRIEFING
M
GD
LP2B-75
LP1F-62
LP1F-64
TV
72"
PROJECTOR
PROJECTOR
9.227
GFCI
9.226
MS
LP1F-66
9.228
L5-30R
LP1F-68
LP1F-70
L5-30R
LP1F-72
LP1F-74
LP1F-78
LP1F-76
L5-30R
T
T
16 16
15 15
14 14
ELEC
PANEL LP1B
M
TS
PANEL LP1X
INV
FMCPMIP
COMM
9.213
L5-30R
L5-30R
UH-2
LP1B-8
LP1B-10
LP1B-14
LP1B-12
LP1B-2
LP1B-2
LP1B-2
LP1B-4LP1B-6 44"
MSB
4" CONCRETE
PAD
2'
0"
4' - 0" 9.221
D
D
20 20
19 19
18 18
ELEC
FIRE ALARM
PANEL LP1F
PANEL LP1G
FMCP
LP1G-14
LP1G-30
LP1G-30
R
R
S
S
T
T
13 13
12 12
11 11EF-2
(ROOF)
CP-1 GWH-1
P-4
P-5
TCP P-3 P-2 P-1
HWB-1HWB-2HWB-3 UH-1
44"
MECH
DDC
LP1B-22
LP1B-24
LP1B-73LP1B-73
LP1B-55
LP1B-67,69,71
LP1B-61,63,65
LP1B-22
LP1B-24
LP1B-59 LP1B-59 LP1B-59
LP1B-57 LP1B-57 LP1B-57
LP1B-24
VFD
CRAC-3
LP1B-35,37
(ROOF)
39,41
ACCU-3
M
M
M
S S S
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
5/ 3/
:3
6:
P M
C :\R ev it
Lo ca l\3
-1
9.
-E
-C en tra l-2
7_ m rf.
rv t
W
IS
C O
N
SI
N A
IR
N
AT
IO
N
AL
G U
AR
D
TR
U
AX
F
IE
LD
A N
G B
M
AD
IS
O
N , W
I
AD
AL
B
E-131
FIRST FLOOR PLAN -
POWER
XGFG132020ANG NO.:
3141300-141489.01
MRF
ARG
May 4, 2017
JRH/MRF
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"1 FIRST FLOOR PLAN - POWER
PLAN
NORTH
TRUE
NORTH
1/4" = 1'-0"2 ENLARGED POWER PLAN - ELEC 170 & COMM 171
PLAN
NORTH
TRUE
NORTH
1/4" = 1'-0"3 ENLARGED POWER PLAN - ELEC 127 & FIRE ALARM 126
KEYED NOTES
9.201 SIMULATOR SERVER/TELECOMMUNICATION ELECTRICAL CONNECTION.
VERIFY EXACT NEMA CONFIGURATION IN FIELD.
9.202 SECURE AREA PERIMETER. COORDINATE WITH GENERAL CONTRACTOR.
MINIMIZE, CO-LOCATE, AND SEAL ALL SECURE AREA PENETRATIONS. SEE
DETAIL 1/E-501. CAULK AND SEAL ALL CONDUIT PENETRATIONS IN A
MANNER THAT MAINTAINS ROOM'S SOUND TRANSMISSION CLASS (STC)
RATING OF 55.
9.203 DOTTED LINE INDICATES BOUNDARY OF SOUND ASSEMBLY GROUP 4 -
MINIMUM STC 55. CAULK AND SEAL ALL CONDUITS IN A MANNER THAT
MAINTAINS ROOM'S SOUND TRANSMISSION CLASS (STC) RATING OF 55.
9.205 PROVIDE (3) 4" PVC CONDUITS. CONDUIT SHALL BE STUBBED OUT OF
BUILDING 3'-0" AND BELOW GRADE TO CONNECT WITH UTILITY PROVIDED
SECONDARY FEEDER. COORDINATE INSTALLATION WITH UTILITY PRIOR TO
INSTALLATION.
9.207 PROVIDE WIREMOLD V2400 (OR EQUAL) DUAL CHANNEL STEEL SURFACE
MOUNTED RACEWAY WITH DIVIDERS. SURFACE MOUNTED RACEWAY SHALL
BE INSTALLED AT 18" AFF, UNLESS NOTED OTHERWISE.
9.208 VERIFY NEMA CONFIGURATION WITH ACTUAL EQUIPMENT INSTALLED.
9.209 GROUND METAL WATER PIPES PENETRATING SECURE WALLS IN THIS
LOCATION. GROUNDING CONNECTION SHALL BE ON SECURE SIDE OF
PERIMETER INDICATED. REFER TO MECHANICAL, PLUMBING AND FIRE
PROTECTION PLANS FOR EXACT QUANTITY OF WATER PIPES. GROUND
WITH #4AWG.
9.210 SECURE AREA PERIMETER. COORDINATE WITH GENERAL CONTRACTOR.
MINIMIZE, CO-LOCATE, AND SEAL ALL SECURE AREA PENETRATIONS. SEE
DETAIL 1/E-501.
9.211 PROVIDE WIREMOLD V2400 (OR EQUAL) DUAL CHANNEL STEEL SURFACE
MOUNTED RACEWAY WITH DIVIDERS FOR DEVICES INDICATED.
COORDINATE RECEPTACLE/WIREMOLD LOCATION FOR DEVICES AT 42" AND
74" WITH C.O.R. PRIOR TO INSTALLATION.
9.212 PROVIDE WIREMOLD V2400 (OR EQUAL) DUAL CHANNEL STEEL SURFACE
MOUNTED RACEWAY WITH DIVIDERS FOR DEVICES INDICATED.
COORDINATE RECEPTACLE/WIREMOLD LOCATION FOR DEVICES AT 42"
WITH C.O.R. PRIOR TO INSTALLATION.
9.213 MOUNT TO BOTTOM OF (4) POST TELECOM RACK. COORDINATE EXACT
LOCATION IN FIELD WITH ACTUAL TELECOM RACK INSTALLED. FEED WITH
FLEXIBLE METAL CONDUIT.
9.214 PROVIDE WIREMOLD V4000 (OR EQUAL) DUAL CHANNEL STEEL SURFACE
MOUNTED RACEWAY WITH DIVIDERS. PROVIDE (6) TWO-GANG COVERS
WITH (1) DUPLEX RECEPTACLE AND ADAPTER FOR (2) DATA OUTLETS.
COVERS SHALL BE SPACED EVENLY TO ALLOW EASY ACCESS FROM
LAPTOP SLOTS. SURFACE MOUNTED RACEWAY SHALL BE INSTALLED
VERTICALLY ON THE FRONT FACE OF LAPTOP CHARGING STATION CABINET.
COORDINATE WITH GC AND MILLWORK CONTRACTOR PRIOR TO
INSTALLATION. REFER TO ARCHITECTURAL SECTIONS AND ELEVATIONS
FOR ADDITIONAL INFORMATION.
9.215 SAW CUT EXISTING FLOOR SLAB FOR INSTALLATION OF UNDERSLAB
POWER AND DATA CONDUITS. PATCH FLOOR TO MATCH NEW SURFACE.
9.216 PROVIDE DOUBLE-GANG, FULLY ADJUSTABLE, CAST-IRON FLOOR BOX
(WIREMOLD OMNIBOX OR EQUAL). PROVIDE MATCHING BRUSHED
ALUMINUM COVER PLATE FLANGE AND COVER PLATE. COORDINATE EXACT
LOCATION OF FLOOR BOX WITH OWNER AND ARCHITECT PRIOR TO
INSTALLATION.
9.217 ROUTE (2) #12, (1) #12 GND IN 3/4" C. TO NEW JUNCTION BOX FOR FUTURE
ACCESS CONTROL AT EXTERIOR DOOR. JUNCTION BOX SHALL BE LOCATED
ABOVE ACCESSIBLE CEILING.
9.218 MOUNT DUPLEX RECEPTACLE ON MECHANICAL EQUIPMENT LOCATED ON
ROOF.
9.219 ALL 120V NORMAL POWER DEVICES LOCATED IN THIS ROOM SHALL BE FED
FROM PANEL 'LP1X' UNLESS NOTED OTHERWISE.
9.220 PROVIDE WIREMOLD V2400 (OR EQUAL) DUAL CHANNEL STEEL SURFACE
MOUNTED RACEWAY WITH DIVIDERS FOR DEVICES INDICATED.
COORDINATE RECEPTACLE/WIREMOLD LOCATION FOR DEVICES AT 44"
WITH COR PRIOR TO INSTALLATION.
9.221 DIMENSIONS SHOWN FOR 'MSB' REPRESENT THE MAXIMUM ALLOWABLE
DEPTH AND WIDTH OF EQUIPMENT NEEDED TO BE INSTALLED.
9.222 COORDINATE EXACT LOCATION OF SIM PANEL AND DISCONNECT WITH
SIMULATOR EQUIPMENT PROVIDER AND INSTALLER.
9.224 PROVIDE WIREMOLD V2400 (OR EQUAL) DUAL CHANNEL STEEL SURFACE
MOUNTED RACEWAY WITH DIVIDERS FOR DEVICES INDICATED.
COORDINATE RECEPTACLE/WIREMOLD LOCATION FOR DEVICES AT 74"
WITH COR PRIOR TO INSTALLATION.
9.225 RECEPTACLE SHALL SERVE OVERHEAD COILING DOOR. RECEPTACLE
SHALL BE LOCATED ABOVE ACCESSIBLE CEILING. COORDINATE EXACT
LOCATION WITH GC AND C.O.R. PRIOR TO INSTALLATION.
9.226 PROVIDE WIREMOLD V2400 (OR EQUAL) DUAL CHANNEL STEEL SURFACE
MOUNTED RACEWAY WITH DIVIDERS FOR DEVICES INDICATED.
COORDINATE RECEPTACLE/WIREMOLD LOCATION FOR DEVICES AT 18" AND
72" WITH C.O.R. PRIOR TO INSTALLATION.
9.227 COORDINATE EXACT LOCATION OF PROJECTOR DUPLEX RECEPTACLE
INTENDED FOR DOCUMENT VISUALIZER PRIOR TO INSTALLATION.
9.228 MOTORIZED SCREEN IS GFGI. EC SHALL PROVIDE POWER WIRING TO
MOTORIZED SCREEN AND LOW VOLTAGE WIRING TO SWITCH. COORDINATE
EXACT LOCATION WITH C.O.R. PRIOR TO INSTALLATION.
PLAN
NORTH
TRUE
NORTH
1/4" = 1'-0"4 ENLARGED POWER PLAN - MECH 172
1/2" MINIMUM
SEPARATION BETWEEN
STEEL CONDUIT
CLASS 1 TYPE A
DIELECTRIC LINK
THREADED COUPLING
(SCH. 80 PVC)
SECURE AREA INTERIOR WALL
SEAL WITH ACOUSTICAL FIRE PROOF
SEALANT ALL THE WAY AROUND
FINISHED FLOOR
84" AFF OR 6" BELOW
CEILING, WHICHEVER IS
LOWER
46"
18"
POWER, TELEPHONE AND DATA
RECEPTACLES LOCATED IN
OFFICES AND OTHER FINISHED
AREAS UNLESS NOTED
OTHERWISE.
ALL SWITCHES AND WALL MOUNTED
PHONES. POWER RECEPTACLES
LOCATED IN UNFINISHED AREAS
UNLESS NOTED OTHERWISE.
ALL FIRE ALARM AUDIBLE,
VISUAL, AND AUDIBLE/VISUAL
DEVICES UNLESS NOTED
OTHERWISE.
NOTES:
MOUNTING HEIGHT DIMENSION FOR ELECTRICAL RECEPTACLES AND
VOICE/DATA OUTLETS ABOVE COUNTER IS HEIGHT AFF TO BOTTOM OF
OUTLET BOX.
TOP OF DEVICE
BOTTOM OF
OUTLET BOX
1.
MOUNTING HEIGHT TO
OPERATING HANDLE
46" AFF.
ALL FIRE ALARM PULL
STATION DEVICES UNLESS
NOTED OTHERWISE.
INVERTER
NL G
PT
L S N
LOCAL ROOM LIGHT SWITCH
ROOM OCCUPANCY SENSOR
NORMAL LIGHTING FIXTURE.
FOR TYPE SEE LIGHTING PLANS
EMERGENCY LIGHTING FIXTURE.
FOR TYPE SEE LIGHTING PLANS
UNIT SHALL BE MANUFACTURED BY
LVS, TYPE LVS, TYPE EPC OR BE
EQUIVALENT BODINE, IOTA OR
DUAL-LITE. PROVIDE WITH TEST
SWITCH.
EXIT
SIGN
#3/0 GRD
#3/0 GRD
#2 GRD
#6 GRD
TO TELECOM ROOM GROUNDING
BUSBAR
(TGB)
#3/0 GRD
#3/0 GRD
TO TELECOM ROOM GROUNDING
BUSBAR
(TGB)
CABLE TRAY
TELECOM EQUIPMENT RACK(S)
MAIN TELECOM ROOM
MAIN GROUNDING BUSBAR (TMGB)
STREET SIDE OF BUILDING
WATER METER. CONNECT TO
METALLIC WATER MAIN
WITHIN 5'-0" OF WATER
SERVICE ENTRANCE. PROVIDE
JUMPER ACROSS WATER METER.
MSB GROUND BUS
PROVIDE EXOTHERMIC WELD FOR
CONNECTION OF CONDUCTORS TO
GROUND BUS OR CONDUCTORS CAN BE
ATTACHED USING CRIMPED ON LUGS
(WITH LISTED CRIMPER) AND BOLTED TO
GROUND BUS.
MDP
NEUTRAL BUS
NOTES:
1. ALL GROUND CONDUCTORS TO BE ROUTED IN PVC CONDUIT.
2. ALL GROUND CONDUCTORS ON THIS DIAGRAM SHALL BE COPPER.
#3/0 AWG
REMOVABLE LINK
BUILDING STEEL
PROVIDE NEW GROUNDING CONNECTION
AT EXISTING BUILDING STEEL IN ELEC 174.
#3/0 GRD
GROUNDING ELECTRODE CONDUCTOR
SIZED PER NEC 250.66.
3/4" X 10'-0" COPPERWELD GROUND
ROD. SEE FLOOR PLANS AND
SPECIFICATION SECTION 26 05 26.
BL
BLUE LIGHT BEACON
NORMALLY OPEN CONTACT
NORMALLY CLOSED CONTACT
MOMENTARY SWITCH NORMALLY OPEN
MOMENTARY SWITCH NORMALLY CLOSED
X CONTROL RELAY
TERMINA / CONNECTION
CONTROLS LEGENDSYMBOL
M
BL
BL
L
MASTER ON
MASTER OFF
LP1X-1
MB
MA
WHT/BLK
WHT/YEL N
BLK
BLK
WHT
WHT
YEL
YEL
LA
LB
LOCAL OVERRIDE
TYPICAL COMMON AREA. NO
LOCAL FLASH OVERRIDE
TYPICAL PRIVATE ROOM WITH
LOCAL FLASH OVERRIDE.
PROVIDE QUANTITY AS
INDICATED ON SHEET E-101.
BLUE LIGHT SYSTEM SEQUENCE OF OPERATION:
WHEN AN ESCORT PUSHES THE ON BUTTON IN THE MASTER PUSHBUTTON
STATION LOCATED IN ROOM 103 THE FOLLOWING OPERATIONS SHALL OCCUR.
THE FLASHING BLUE LIGHT IN EACH OF THE BLUE LIGHT ASSEMBLIES SHALL
TURN ON AND START FLASHING.
WHEN ONE OF THE USERS PRESSES ONE OF THE LOCAL OVERRIDE
PUSHBUTTONS THE FOLLOWING OPERATION SHALL OCCUR.
THE FLASHING BLUE LIGHT CLOSEST TO THE LOCAL OVERRIDE SWITCH SHALL
STOP FLASHING AND REMAIN IN A "STEADY ON" STATE.
WHEN AN ESCORT PUSHES THE OFF BUTTON IN THE MASTER PUSHBUTTON
STATION LOCATED IN ROOM 103 THE FOLLOWING OPERATIONS SHALL OCCUR.
THE FLASHING BLUE LIGHT IN EACH OF THE BLUE LIGHT ASSEMBLIES SHALL
TURN OFF.
THE STEADY BLUE LIGHT IN EACH OF THE BLUE LIGHT ASSEMBLIES SHALL
TURN OFF.
ALL LOCAL OVERRIDE RELAYS SHALL RESET AND RETURN TO THE NORMALLY
CLOSED POSITION.
1.
1.
1.
2.
3.
TO NEXT VRF(S) IF
APPLICABLE. REFER TO
SHEET E-602 FOR EQUIPMENT
WIRING SCHEDULE
30A, 600VAC DOUBLE POLE
MANUAL MOTOR STARTER,
TYPICAL
NOTES:
1. PHASE WIRING ONLY SHOWN, GROUND WIRING NOT SHOWN FOR CLARITY.
208V, 1PH POWER SOURCE
SEE SHEET E-131 FOR POWER SOURCE/CIRCUITRY
VRF VRF VRF
R
Y
G
N120VAC
LP1X-9
R
Y
G
WHT
R
Y
G
R
Y
G
R
Y
G
R
Y
G
R
Y
G
R
Y
G
RED
YEL
BLU
RIB
R
RIB
Y
RIB
G
ERLD
ALERT SCRAMBLE
INDICATOR RELAY BOX
#12 AWG
R
Y
G
R
Y
G
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
5/ 2/
1:
:2
AM
C :\R ev it
Lo ca l\3
-1
9.
-E
-C en tra l-2
7_ m rf.
rv t
W
IS
C O
N
SI
N A
IR
N
AT
IO
N
AL
G U
AR
D
TR
U
AX
F
IE
LD
A N
G B
M
AD
IS
O
N , W
I
AD
AL
B
E-501
DETAILS
XGFG132020ANG NO.:
3141300-141489.01
MRF
ARG
May 4, 2017
JRH/MRF
NO SCALE1 SECURE AREA PENETRATION DETAIL
NO SCALE2 DEVICE MOUNTING HEIGHT
NO SCALE3 INVERTER WIRING DIAGRAM
NO SCALE5 GROUNDING SYSTEM DETAIL (TYP)
NO SCALE4 BLUE LIGHT SYSTEM
NO SCALE6 TYPICAL VRF WIRING SCHEMATIC - MULTIPLE UNITS
NO SCALE7 ALERT SCRAMBLE LIGHT SYSTEM
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
5/ 2/
1:
:3
AM
C :\R ev it
Lo ca l\3
-1
9.
-E
-C en tra l-2
7_ m rf.
rv t
W
IS
C O
N
SI
N A
IR
N
AT
IO
N
AL
G U
AR
D
TR
U
AX
F
IE
LD
A N
G B
M
AD
IS
O
N , W
I
AD
AL
B
E-601
SCHEDULES
XGFG132020ANG NO.:
3141300-141489.01
MRF
ARG
May 4, 2017
JRH/MRF
CHORIDE/PHILIPS
EBU LITHONIA ELM2-LED-SD EMERGENCY BATTERY UNIT LED UNV - W - 2-5/8" 1.44 -
SURE-LITES/EATON
CHORIDE/PHILIPS
X1 LITHONIA LE-S-1-R-ELN-SD SINGLE FACE EXIT SIGN LED UNV - V V 1.75" 1 -
SURE-LITES/EATON
COOPER/EATON
OA LITHONIA
DSXW2 LED-20C-350-40K
-T3M-MVOLT-DMG-PIR1F
C3V-SPD-DDBXD
EXTERIOR WALL MOUNT LED, 4000K UNV D W - 10" 25 2,999
GARDCO/PHILIPS
PHILIPS
U2 FINELITE UC-E-22"-SILVER-PS-XX
W-OCC 22" UNDERCABINET LED, 4000K 120 E S - 0.85 6.1 380
LITHONIA
PHILIPS
U1 FINELITE UC-E-12"-SILVER-PS-XX
W-OCC 12" UNDERCABINET LED, 4000K 120 E S - 0.85 4 196
LITHONIA,
FINELITE
U PHILIPS 523-000027-76 19" UNDERCABINET LED, 4000K 120 E S - 0.88 13 479
COOPER/EATON
METALUX
L CREE LS4-25L-40K-10V 4' LINEAR STRIP LED, 4000K UNV D S - 3" 23 2,500
LITHONIA
ILIGHT TECHNOLOGIES
K MODA LIGHT FF-W-4000K
KINDA-S-W FLEXIBLE LED TAPE FIXTURE - COVE LIGHTING LED, 4000K 120 D S GWB 0.2" 4 / FT 311 / FT
TIVOLI
PRUDENTIAL LIGHTING
J1 AXIS BBRLED-B3-MF-400-80-4
0-FL-5-W-UNV-D-1 5' LINEAR LED, 4000K UNV D R LG 3-15/16" 3.6 / FT 400 / FT
LUMENWERX
PRUDENTIAL LIGHTING
J AXIS BBRLED-B3-MF-400-80-4
0-FL-3-W-UNV-D-1 3' LINEAR LED, 4000K UNV D R LG 3-15/16" 3.6 / FT 400 / FT
LUMENWERX
GOTHAM/ACUITY
H1 PATHWAY C12X6PLCR-850-4K-DG-4
VLEDC12HAZPF-MW 6" DIAMETER CYLINDER DOWNLIGHT LED, 4000K UNV D P ES 12" 11 850
CAPRI/PHILIPS
GOTHAM/ACUITY
H PATHWAY C12X6PLCR-850-4K-DG-4
VLEDC12HAZPF-MB 6" DIAMETER CYLINDER DOWNLIGHT LED, 4000K UNV D P ES 12" 11 850
CAPRI/PHILIPS
PRUDENTIAL LIGHTING
G6 AXIS BBRLED-B3-MF-400-80-4
0-1.5P-S10-W-UNV-D-1 10' LINEAR LED, 4000K UNV D R LG 3-15/16" 3.6 / FT 400 / FT
LUMENWERX
PRUDENTIAL LIGHTING
G5 AXIS BBRLED-B3-MF-400-80-4
0-1.5P-S15-W-UNV-D-1 15' LINEAR LED, 4000K UNV D R LG 3-15/16" 3.6 / FT 400 / FT
LUMENWERX
PRUDENTIAL LIGHTING
G4 AXIS BBRLED-B3-MF-400-80-4
0-1.5P-S15-W-UNV-D-2 15' LINEAR LED, 4000K UNV D R LG 3-15/16" 3.6 / FT 400 / FT
LUMENWERX
PRUDENTIAL LIGHTING
G3 AXIS BBRLED-B3-MF-400-80-4
0-1.5P-S16-W-UNV-D-1 16' LINEAR LED, 4000K UNV D R LG 3-15/16" 3.6 / FT 400 / FT
LUMENWERX
PRUDENTIAL LIGHTING
G2 AXIS BBRLED-B3-MF-400-80-4
0-1.5P-S16-W-UNV-D-2 16' LINEAR LED, 4000K UNV D R LG 3-15/16" 3.6 / FT 400 / FT
LUMENWERX
PRUDENTIAL LIGHTING
G1 AXIS BBRLED-B3-MF-400-80-4
0-1.5P-S24-W-UNV-D-2 24' LINEAR LED, 4000K UNV D R LG 3-15/16" 3.6 / FT 400 / FT
LUMENWERX
PRUDENTIAL LIGHTING
G AXIS BBRLED-B3-MF-400-80-4
0-1.5P-S24-W-UNV-D-1 24' LINEAR LED, 4000K UNV D R LG 3-15/16" 3.6 / FT 400 / FT
LUMENWERX
DAYBRITE/PHILIPS
F2 METALUX 4-ILED-5-W-WG-UNV-L84
0-CD-1-U 4' INDUSTRIAL LED, 4000K UNV D S ES 4-15/16" 36.6 5,101
LITHONIA/ACUITY
DAYBRITE/PHILIPS
F1 METALUX
4-ILED-7-W-WG-UNV-L84
0-CD-1-U-AYC-CHAIN/SE
T/U
4' INDUSTRIAL LED, 4000K UNV D P ES 4-15/16" 56.5 7,246
LITHONIA/ACUITY
DAYBRITE/PHILIPS
F METALUX
4-ILED-5-W-WG-UNV-L84
0-CD-1-U-AYC-CHAIN/SE
T/U
4' INDUSTRIAL LED, 4000K UNV D P ES 4-15/16" 36.6 5,101
LITHONIA/ACUITY
JUNO/ACUITY
D3 HALO H457-TAT-E010-ELG406-
9-40-WH-L113 4" DIAMETER LED ADJUSTABLE DOWNLIGHT LED, 4000K UNV D R GWB 4.59" 13 930
DRYWALL KIT CAPRI/PHILIPS
JUNO/ACUITY
D2 HALO H457-ICAT-1E-EL406-930
-TL402HS-TRM400SN 4" DIAMETER LED DOWNLIGHT (WET LOCATION) LED, 4000K 120 D R GWB 5-3/8" 13 900
38 CAPRI/PHILIPS
COOPER/EATON
D1 CREE KR6-13L-40K-120V-10V
KR6TR-SSGC-WF 6" DIAMETER DOWNLIGHT LED, 4000K 120 D R V 7.4" 18 1,100
LITHONIA/ACUITY
COOPER/EATON
D CREE KR6-9L-40K-120V-10V
KR6TR-SSGC-WF 6" DIAMETER DOWNLIGHT LED, 4000K 120 D R V 7.4" 13 700
LITHONIA/ACUITY
COOPER/EATON
C1 CREE CR14-22L-40K-10 1' X 4' VOLUMETRIC TROFFER LED, 4000K UNV J R LG 4.5" 22 2,200
LITHONIA/ACUITY
COOPER/EATON
C CREE CR14-22L-40K-10-DGA-14
-WHT 1' X 4' VOLUMETRIC TROFFER LED, 4000K UNV J R DW 4.5" 22 2,200
LITHONIA/ACUITY
BL EDWARDS SIGNAL 125XBRMB120A BLUE LIGHT BEACON LED 120 - V V 3.875" - -
COOPER/EATON
B CREE LR22-34L-40K-10V 2' X 2' TROFFER LED, 4000K UNV J R LG 3.6" 35 3,400
LITHONIA/ACUITY
AL FEDERAL SIGNAL LSLD-120-G-A-R GREEN/ORANGE/RED ALERT SCRAMBLE INDICATOR BEACON LED 120 - S LG 13.05" - -
DES. MANUFACTURER CATALOG SERIES DESCRIPTION LAMP DATA VOLTAGE BALLAST/
DRIVER MOUNT CEILING
TYPE
FIXTURE
DEPTH
LED
SYSTEM
INPUT
WATTAGE
LED
DELIVERED
LUMENS
OPTIONS /
ACCESSORIES
ACCEPTABLE
MANUFACTURERS
KEYED
NOTE
LG = LAY-IN GRID PL = POLE MOUNTED UNV = UNIVERSAL VOLTAGE
ES = EXPOSED STRUCTURE PLAS = PLASTER S = SURFACE W = WALL MOUNTED
ABBREVIATIONS: GWB = GYPSUM WALL BOARD P = PENDANT R = RECESSED V = VARIES
NOTE: SEE SPECIFICATION FOR ADDITIONAL INFORMATION REGARDING LUMINAIRE AND INSTALLATION REQUIREMENTS. PROVIDE OPTIONS AND ACCESSORIES REFERENCED BY THE COLUMN TITLED " OPTIONS/ACCESSORIES". MANUFACTURERS LISTED ACCEPTABLE SHALL MEET ALL REQUIREMENTS AND FEATURES INDICATED. ACCEPTABLE MANUFACTURERS MUST MEET THE PHOTOMETRIC PERFORMANCE OF THE LISTED UNIT.
LUMINAIRE SCHEDULE
2. PROVIDE (1) OCCUPANCY SENSOR AND PROPER POWER SUPPLY SIZE FOR EACH
SWITCHING ARRANGEMENT SHOWN ON LIGHTING FLOOR PLAN.
1. FIELD VERIFY AND PROVIDE EXACT LENGTH OF FIXTURE REQUIRED TO
ACCOMMODATE THE DESIGNATED LOCATION SHOWN ON LIGHTING PLANS. PROVIDE
ALL ACCESSORIES REQUIRED TO CREATE A COMPLETE AND OPERATIONAL SYSTEM.
DIMMABLE POWER SUPPLY QUANTITIES SHALL BE VERIFIED BASED ON ACTUAL
LENGTH. FOR BIDDING PURPOSES ASSUME MIN. OF 100W POWER SUPPLY PER EVER...
KEYED NOTES:
1. EC SHALL VERIFY AND COORDINATE ALL LUMINAIRE TRIMS/FLANGES WITH
RESPECTIVE CEILING TYPES SCHEDULED AND/OR SUBMITTED BY THE GC PRIOR TO
ORDERING OF THE LUMINAIRES. SCHEDULE INDICATES TRIM TYPES BASED ON THE
GENERIC CEILING INFORMATION AVAILABLE AT THE TIME BIDDING DOCUMENTS WERE
ISSUED AND DOES NOT REFLECT ACTUAL THICKNESS OF GYPSUM WALL BOARD OR
PLASTER CEILING OR EXACT GRID TYPE SPECIFIED BY THE ARCHITECT.
GENERAL NOTES:
J LED DIMMABLE POWER SUPPLY (0-10V) (DIMMING TO 5%).
H LED DIMMABLE POWER SUPPLY ADVANCE XITANIUM OR EQUAL.
G LED DIMMABLE POWER SUPPLY 1% DIMMING LUTRON HI LUME OR EQUAL.
F LED DIMMABLE POWER SUPPLY (TRAILING EDGE).
E LED NON-DIMMABLE POWER SUPPLY
D LED DIMMABLE POWER SUPPLY (0-10V).
BALLAST/DRIVER CODE LISTING: (SEE SPECIFICATIONS)
38 WET LOCATION LISTED
37 FROSTED LENS REFLECTOR, SATIN LENS DIFFUSER
36 CUSTOM PAINTED FINISH - COLOR AS SELECTED BY ARCHITECT
35 FURNISH TRIM SUITABLE FOR USE WITH NARROW TEE CLG SYSTEM
34 WHITE STRAIGHT BLADE LOUVERS
33 1/2" X 1/2" X 1/2" SILVER PARACUBE LOUVER
32 FURNISH WITH PHOTO CELL
31 FURNISH WITH SOLID FRONT
30 PATTERN 12 ACRYLIC LENS - 0.187" MIN. THICKNESS
29 PATTERN 12 ACRYLIC LENS - 0.156" MIN. THICKNESS
28 PATTERN 12 ACRYLIC LENS - 0.125" MIN. THICKNESS
27 FURNISH WITH SWIVEL CANOPY
26 FURNISH WITH RIGID PENDANT STEMS
25 FURNISH WITH CHAIN MOUNTING ACCESSORIES
24 FURNISH WITH WIRE GUARD
23 FURNISH WITH AUXILIARY EMERGENCY...
22 FURNISH WITH SLOPE ADAPTER - VERIFY SLOPE
21 FURNISH WITH ASYMMETRIC REFLECTOR
20 FURNISH WITH SYMMETRIC REFLECTOR
19 ADA COMPLIANT
18 BLACK MILLIGROOVE BAFFLE
17 WHITE MILLIGROOVE BAFFLE
16 REFLECTOR COLOR OTHER THAN CLEAR
15 MATTE DIFFUSE CLEAR REFLECTOR
14 STAINLESS STEEL TRIM & DOOR FRAME
13 DAMP LOCATION LISTED
12 ANTIMIRCOBIAL PROTECTION PAINTED FINISH
11 TRIPLE GASKETED DOOR FRAM, LENS & BODY
10 DOUBLE GASKETED DOOR FRAME
09 SINGLE GASKETED DOOR FRAME
08 FLAT STEEL DOOR FRAME
07 REGRESSED ALUMINUM DOOR FRAME
06 FLAT ALUMINUM DOOR FRAME
05 LOW IRIDESCENT PARABOLIC LOUVER
04 SEMI-SPECULAR PARABOLIC LOUVER
03 4" DEEP PARABOLIC LOUVERS
02 3" DEEP PARABOLIC LOUVERS
01 AIR HANDLING CAPABILITY - RETURN AIR
OPTIONS/ACCESSORIES CODE LISTING:
2. REFER TO SPECIFICATIONS FOR DEVICE AND WALL PLATE FINISH COLORS.
1. PROVIDE 20A RATED POWER PACKS WITH ZERO CROSS SWITCHING TECHNOLOGY AND MANUAL ON MODE.
KEYED NOTES:
3. MANUFACTURER SHOWN AS A BASIS OF DESIGN.
2. PROVIDE ADEQUATE SUPPORT FOR CONTROL WIRING.
1. PROVIDE 8' OF ADDITIONAL WIRING ABOVE ACCESSIBLE CEILING.
GENERAL NOTES:
DS 12-24V - - - - 0 FC (MIN) TO 50-750 FC (MAX) DAYLIGHT SENSOR. SEE SPEC
SECTION 26 09 23. CEILING -
OS6 12-24V X X 360 28 FT. SELF-ADJUSTING, CEILING MOUNT, HIGH BAY OCCUPANCY
SENSOR. SEE SPEC SECTION 26 09 23. CEILING 1
OS5 12-24V X X 360 28 FT. SELF-ADJUSTING, CEILING MOUNT OCCUPANCY SENSOR. SEE
SPEC SECTION 26 09 23. CEILING 1
OS4 12-24V X 360 12 FT. SELF-ADJUSTING, UL 924 LISTED, CEILING MOUNT
OCCUPANCY SENSOR. SEE SPEC SECTION 26 09 23. CEILING 1
OS3 12-24V X X 360 28 FT. SELF-ADJUSTING, CEILING MOUNT, HALLWAY OCCUPANCY
SENSOR. SEE SPEC SECTION 26 09 23. CEILING 1
OS2 12-24V X X 360 28 FT SELF-ADJUSTING, CEILING MOUNT OCCUPANCY SENSOR. SEE
SPEC SECTION 26 09 23. CEILING 1
OS1 12-24V X 360 12 FT. SELF-ADJUSTING, CEILING MOUNT OCCUPANCY SENSOR. SEE
SPEC SECTION 26 09 23. CEILING 1
OS 120/277 X 180 12 FT. SINGLE-POLE, WALL MOUNT SWITCH TYPE OCCUPANCY
SENSOR, MANUAL ON/AUTO OFF. SEE SPEC SECTION 26 09 23. SWITCH 2
PIR US
SENSOR
ID…