FOUNDATION NOTES
F-1. ALL COLUMN FOOTINGS ARE TO BE CENTERED UNDER COLUMN
CENTERLINES, UNLESS NOTED OR DETAILED OTHERWISE.
F-2. THE FOUNDATION CONTRACTOR SHALL FULLY REVIEW UNDER-GROUND
PLUMBING DRAWINGS AND SHALL COORDINATE WITH THE UNDER-GROUND
PLUMBING CONTRACTOR TO DEPRESS FOOTINGS AND PROVIDE PIPE
SLEEVES THROUGH FOUNDATION WALLS AS NECESSARY TO ACCOMMODATE
PLUMBING LINES OR TRAPS WHICH PENETRATE CONCRETE FOOTINGS OR
FOUNDATIONS.
F-3. PROVIDE PVC SLEEVES THROUGH FOUNDATION WALLS/FOOTINGS FOR PIPE,
CONDUIT, AND CABLE PENETRATIONS, INCLUDING ELECTRICAL GROUNDING
SYSTEM CABLES. SEE APPROPRIATE DRAWINGS FOR LOCATIONS/SIZES.
PLACE SLEEVES IN LOCATIONS TO AVOID DISPLACING REINFORCING STEEL.
F-4. FOOTING SUBGRADES SHALL BE CLEAN AND FREE OF DEBRIS, STANDING
WATER, AND LOOSE SOIL.
F-5. REFER TO ELECTRICAL DRAWING SITE LIGHTING FOR POLE BASES.
SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR.
F-6. COORDINATE WITH ARCHITECTURAL AND CIVIL DRAWINGS FOR
MISCELLANEOUS FOUNDATIONS NOT SHOWN ON STRUCTURAL DRAWINGS.
F-7. CONTROL JOINTS IN THE CAST-IN-PLACE CONCRETE FOUNDATION WALLS
SHALL BE PLACED AT SPACING NOT TO EXCEED 20' O.C. OR AS LOCATED
PER DRAWINGS AND SHOULD ALIGN WITH MASONRY CONTROL JOINTS
WHERE APPLICABLE. SEE DETAIL SHEETS FOR CONTROL JOINT DETAILS.
PROVIDE VERTICAL "V" GROOVE AT ALL CONSTRUCTION AND CONTROL
JOINTS. CONTRACTOR SHALL SUBMIT PLANS OF JOINT LOCATIONS FOR
APPROVAL.
F-8. SEE TYPICAL SLAB-ON-GRADE DETAILS FOR SLAB AND SUB-BASE
REQUIREMENTS. THESE WILL BE TYPICAL THROUGHOUT UNLESS NOTED
OTHERWISE.
F-9. A LEAN CONCRETE MUD SLAB 2" TO 3" THICK SHALL BE USED IN THE FOOTING
EXCAVATION IF THE BOTTOM OF THE EXCAVATION TENDS TO BECOME
MUDDY AND SOFT DUE TO CONSTRUCTION ACTIVITY. LEAN CONCRETE
SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2000 PSI.
F-10. COORDINATE GROUNDING REQUIREMENTS FOR FOUNDATION/FOOTING
REINFORCING STEEL WITH ELECTRICAL DRAWINGS. COORDINATE
INSTALLATION OF GROUNDING WIRES/EQUIPMENT WITH ELECTRICAL
CONTRACTOR PRIOR TO CASTING CONCRETE.
CONCRETE & REINFORCING STEEL NOTES
MATERIAL PROPERTIES (U.N.O.)
COMPRESSIVE STRENGTH - F'c = 4 KSI CONCRETE REINFORCEMENT - Fy = 60 KSI (A615 GR 60)
CR-1. PROVIDE ONE (1) HOOKED REINFORCING BAR IN CONCRETE FOOTING
TO SERVE AS A “CONCRETE ENCASED ELECTRODE” IN ACCORDANCE
WITH THE NATIONAL ELECTRIC CODE. COORDINATE WITH ELECTRICAL
CONTRACTOR FOR EXACT LOCATION. HOOKED REINFORCING BAR SHALL
CONFORM TO THE FOLLOWING:
A. UNCOATED, LOW-ALLOY STEEL, CONFORMING TO ASTM A706.
B. BAR SIZE NUMBER 4.
C. HOOKED AT ONE END ONLY.
D. MINIMUM HORIZONTAL LENGTH OF REINFORCING BAR ENCASED
IN CONCRETE FOOTING SHALL BE 20’-0” AS DEFINED IN NEC,
ARTICLE 250.
E. MINIMUM VERTICAL PROJECTION OF REINFORCING BAR ABOVE
CONCRETE SLAB SHALL BE 0’-6”.
F. MINIMUM COVER ALL AROUND REINFORCING BAR SHALL BE 2”.
CR-2. ALL BAR LAPS SHALL CONFORM TO ACI 318 CLASS "B" SPLICE CRITERIA.
USE TOP BAR LAP LENGTHS FOR TOP BARS IN SLABS AND BEAMS OVER
14" DEEP. MINIMUM BAR LAPS AS FOLLOWS UNLESS NOTED OTHERWISE:
#3:1'-4" #4:1'-4" #5:1'-10" #6:2'-7" #7:4'-2" #8:5'-2" #9:6'-4" #10:7'-8" #11:9'-0"
FOR EPOXY COATED BARS, PROVIDE 1.5 TIMES THE INDICATED LAP
LENGTH. FOR TOP BARS PROVIDE 1.3 TIMES THE INDICATED LAP LENGTH.
CR-3. LAP LENGTH SHALL BE SPECIFICALLY NOTED ON SHOP DRAWINGS WHERE
MORE THAN ONE BAR MAKES UP A CONTINUOUS STRING.
CR-4. HORIZONTAL BARS SHALL BE DETAILED TO SHOW THE DISTANCE FROM
AT LEAST ONE END OF THE BAR TO THE NEAREST BUILDING GRID LINE OR
WALL.
CR-5. REINFORCING SHALL BE DETAILED IN ACCORDANCE WITH ACI 315.
CR-6. ALL REINFORCEMENT BARS SHALL BE FABRICATED IN ACCORDANCE WITH
THE LATEST CRSI MANUAL OF STANDARD PRACTICE AND SHALL BE CLEAN
AND FREE OF GREASE AND SCALING RUST.
CR-7. CONTINUOUS TOP AND BOTTOM BARS, WHEN SHOWN IN TRANSVERSE
SECTION ONLY, SHALL BE LAPPED AS FOLLOWS:
TOP BARS NEAR MID-SPANS; BOTTOM BARS DIRECTLY OVER SUPPORTS,
UNLESS NOTED OTHERWISE.
CR-8. WATER STOPS SHALL BE PROVIDED IN HORIZONTAL AND VERTICAL
CONSTRUCTION JOINTS WHERE FINISHED FLOOR IS BELOW EXTERIOR
GRADE UNLESS OMISSION IS APPROVED BY THE ENGINEER.
CR-9. HOOK HORIZONTAL WALL AND BEAM REINFORCING BARS AT
DISCONTINUOUS ENDS, TYPICAL UNLESS NOTED OTHERWISE. EXTEND
REINFORCEMENT TO FAR FACE OF PIERS/PEDESTALS AND/OR COLUMNS
UNLESS NOTED OTHERWISE.
CR-10. PROVIDE HOT/COLD WEATHER PROCEDURES AND PROTECTION
IN ACCORDANCE WITH ACI RECOMMENDATIONS AND PROJECT
SPECIFICATIONS.
CR-11. CONCRETE REINFORCEMENT PROTECTION/CLEAR COVER,
UNLESS NOTED OTHERWISE:
FOOTINGS:
BOTTOM & SIDES 3"
TOP 2"
WALLS:
EXTERIOR EXPOSURE 2"
INTERIOR EXPOSURE 1"
BEAMS/COLUMNS:
OVER TIES OR STIRRUPS 1 1/2"
ELEVATED SLABS: 1"
CR-12. PROVIDE ADDITIONAL #4 BARS AT 4'-0" LONG 1" BELOW TOP OF SLAB AT
45° TO ALL REENTRANT CORNERS,OPENINGS IN CONCRETE SLABS AND
AS INDICATED ON DRAWINGS.
CR-13. ALL CONCRETE FOUNDATION WALLS SHALL HAVE A MINIMUM OF
(2) #5 BARS CONTINUOUS TOP AND BOTTOM, UNLESS NOTED OR
DETAILED OTHERWISE.
CR-14. EXTEND ALL PIER STEEL TO PROVIDE STD. HOOK UNDER FOOTING
REINFORCEMENT, UNLESS NOTED OTHERWISE.
CR-15. ALL CONCRETE DESIGN AND CONSTRUCTION SHALL CONFORM WITH THE
LOCAL BUILDING CODE REQUIREMENTS AND THOSE OF THE FOLLOWING
STANDARDS (LATEST EDITION):
"ACI 318, BUILDING CODE REQUIREMENTS FOR REINFORCED CONC."
"ACI 315, DETAILS AND DETAILING OF CONCRETE REINFORCEMENT"
"ACI 301, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BLDGS."
"ACI 307, RECOMMENDED PRACTICE FOR CONCRETE FORM WORK"
CR-16. SEE SECTION 033000 OF SPECIFICATIONS FOR INFORMATION REGARDING
CONCRETE MIX DESIGN, TESTING, MATERIALS, AND ADMIXTURES.
CR-17. ALUMINUM CONDUIT IS NOT PERMITTED TO BE EMBEDDED IN CONCRETE.
CR-18. REFER TO FLATWORK DRAWINGS AND/OR SPECIFICATIONS FOR
SLAB-ON-GRADE FINISH TYPES AND DEPRESSIONS REQUIRED FOR MATS,
TILE, AND OTHER FINISH MATERIALS.
CR-19. PROVIDE FOOTING DOWELS TO MATCH VERTICAL WALL REINFORCING.
WHERE WALL REINFORCING IS NOT INDICATED, DOWEL FOOTING TO
FOUNDATION WALLS WITH #5 REBAR AT 16" O.C. BY 3'-0" LONG, WITH
STANDARD HOOKS EMBEDDED A MINIMUM OF 9" INTO FOOTING.
CR-20. ALL PIER FOOTINGS TO HAVE DOWELS WITH STANDARD HOOKS OF SAME
SIZE AND QUANTITY AS PIER STEEL. DOWELS TO LAP PIER STEEL AS
REQUIRED FOR A CLASS "B" TENSION SPLICE.
CR-21. ALL OPENINGS IN CONCRETE FOUNDATION WALLS ARE TO HAVE (4) #5
DIAGONAL BARS EACH FACE OF THE WALL UNLESS OTHERWISE NOTED.
BARS SHALL EXTEND 2 FEET BEYOND OPENING ON EACH SIDE.
CR-22. UNLESS NOTED OTHERWISE, THICKEN THE SLAB-ON-GRADE BENEATH
INTERIOR MASONRY PARTITIONS 8 INCHES BELOW BOTTOM OF SLAB ON
GRADE. THICKENED PORTION TO EXTEND 8 INCHES BEYOND THE FACE
OF THE WALL ON EACH SIDE. REINFORCE THE THICKENED PORTION
WITH (3) #5 CONTINUOUS, LONGITUDINAL REINFORCING BARS AND
#5 TRANSVERSE BARS AT 16" O.C., UNLESS NOTED OTHERWISE.
CR-23. PITCH CONCRETE TO FLOOR DRAINS. COORDINATE WITH PLUMBING AND
ARCHITECTURAL DRAWINGS.
CR-24. UNLESS NOTED OTHERWISE, PROVIDE CONTROL OR CONSTRUCTION
JOINTS IN SLABS-ON-GRADE AT 15 FOOT MAXIMUM CENTERS EACH
DIRECTION. CONTRACTOR SHALL SUBMIT PLANS OF JOINT LOCATIONS
TO THE CONTRACTING OFFICER'S REPRESENTATIVE FOR APPROVAL
PRIOR TO CASTING SLABS-ON-GRADE. COORDINATE WITH ARCH-
ITECTURAL DRAWINGS AND FLOOR FINISHES SUCH AS TILE AND TERRAZZO.
CR-25. ALL DOWELS INTO EXISTING CONCRETE OR SOLID MASONRY TO BE
EPOXY ANCHORED WITH HILTI HIT-RE 500-SD ADHESIVE OR EQUIVALENT,
(UNLESS INDICATED OTHERWISE.)
GENERAL NOTES
G-1. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO START
OF CONSTRUCTION - RESOLVE ANY DISCREPANCY WITH CONTRACTING
OFFICER'S REPRESENTATIVE.
G-2. FOR CLARITY, ALL EXTERIOR SLABS AND SIDEWALKS MAY NOT BE SHOWN.
FOR EXACT DIMENSIONS, LOCATIONS, JOINTS AND SCORE LINES, SEE
ARCHITECTURAL AND/OR CIVIL DRAWINGS.
G-3. VERIFY ALL SIZES, WEIGHTS AND LOCATIONS OF MECHANICAL AND
ELECTRICAL EQUIPMENT, ROOF PENETRATIONS, DUCTS, ETC. WITH
MECHANICAL AND ELECTRICAL CONTRACTORS AND FIELD CONDITIONS.
G-4. DETAILS MARKED "TYPICAL" MAY OR MAY NOT BE CUT ON PLANS,
BUT SHALL APPLY UNLESS NOTED OTHERWISE.
G-5. STRUCTURAL SYSTEM IS DESIGNED TO WORK AS A COMPLETED SYSTEM,
ANY SHORING OR BRACING NECESSARY DURING CONSTRUCTION SHALL BE
THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
G-6. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING PLANS
FOR SLEEVES, INSERTS, ETC. NOT SHOWN ON STRUCTURAL PLANS.
G-7. NO PIPES OR SLEEVES FOR MECHANICAL TRADES SHALL PASS THROUGH
STRUCTURAL MEMBERS WITHOUT APPROVAL OF THE STRUCTURAL
ENGINEER.
G-8. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL SITE SAFETY
AND ALL ACCIDENTS WHICH RESULT IN DEATH, PERSONAL INJURY, OR
DAMAGE TO PROPERTY ARISING OUT OF OR IN CONNECTION WITH THE
PERFORMANCE OF THE WORK.
G-9. IT IS THE OWNER'S RESPONSIBILITY TO POST LIVE LOADS PER
SECTION 1603.3 OF THE GOVERNING CODE.
G-10. SECTIONS, DETAILS, AND NOTES SHOWN ON THE DRAWINGS ARE INTENDED
TO BE TYPICAL AND SHALL APPLY TO SIMILAR CONDITIONS ELSEWHERE,
UNLESS OTHERWISE SHOWN.
DO NOT SCALE DRAWINGS!!!!
EARTHWORK NOTES
EW-1. SEE GEOTECHNICAL REPORT AND SPECIFICATIONS FOR DEFINITION OF
MATERIALS AND COMPACTION REQUIREMENTS.
EW-2. UNLESS NOTED OTHERWISE, THE CONTRACTOR SHALL RETAIN AN
INDEPENDENT, QUALIFIED GEOTECHNICAL ENGINEERING FIRM/TESTING
AGENCY TO IDENTIFY AREAS OF POOR SOILS, TO MONITOR PROPER
SUBGRADE PREPARATIONS AND TO OVERSEE AND TEST THE PLACEMENT
OF COMPACTED FILL MATERIAL.
EW-3. ALL SUBTERRANEAN STRUCTURES, UTILITIES, PIPING, ETC. IIN THE AREA
OF EXCAVATIONS TO BE LOCATED AND MARKED BY CONTRACTOR PRIOR
TO EARTH REMOVAL WORK. CONTRACTOR TO MAINTAIN MARKERS UNTIL
EXCAVATION ACTIVITIES HAVE CEASED. IF UNDERGROUND UTILITY
CONFLICTS ARE DISCOVERED BEFORE OR ENCOUNTERED DURING
EXCAVATION, NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY.
EW-4. BEFORE PLACING FOOTINGS, FOUNDATIONS OR SLAB-ON-GRADE, THE
SUB-GRADE SHALL BE PREPARED AND INSPECTED AS REQUIRED BY THE
SPECIFICATIONS.
EW-5. REFERENCE THE GEOTECHNICAL REPORT INCLUDED IN THE PROJECT
MANUAL FOR REQUIREMENTS FOR EXCAVATION AND CONTROL OF GROUND
WATER DURING CONSTRUCTION. EXISTING SOILS MAY EXPERIENCE A LOSS
OF STRENGTH IF SURFACE WATER IS ALLOWED TO ACCUMULATE IN THE
EXCAVATIONS; DO NOT ALLOW SURFACE WATER TO ACCUMULATE IN THE
BOTTOM OF EXCAVATIONS.
EW-6. WHERE STRUCTURES DERIVE SUPPORT FROM FILL-SUPPORTED
FOUNDATIONS AND AT SLAB-ON-GRADE, FILL SHALL BE COMPACTED
TO 98% OF STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D-698),
UNLESS NOTED OTHERWISE.
EW-7. NO FILL SHALL BE PLACED OVER FROZEN, MUDDY, OR OTHER DELETERIOUS
MATERIAL. NO FILL SHALL BE PLACED OVER A PREVIOUS LIFT THAT HAS
NOT BEEN ADEQUATELY COMPACTED PER SPECIFICATIONS.
EW-8. BACKFILL AGAINST FOUNDATION WALLS SHALL BE PLACED EVENLY ON
ALL SIDES IN ORDER TO ACHIEVE GENERALLY BALANCED LOADINGS.
ABBREVIATIONS
B.
GENERAL SYMBOLS
KEYED NOTE
STRUCTURAL WALL TYPE
ELEVATION
DECK SPAN
STRUCTURAL SLAB TYPE
STRUCTURAL ELEVATION
DETAIL OR SECTION
LINTEL DESIGNATION
SLAB X
S-201 #
S-501
SW#
STRUCTURAL SYMBOLOGY
MASONRY (CMU) WALL
ON CONCRETE FOOTING
CONCRETE FOOTING
CONCRETE FOUNDATION WALL
ON CONCRETE FOOTING
TOP OF FOOTING ELEVATION
TOP OF WALL ELEVATION
FOOTING STEP
STRIP FOOTING DESIGNATION
DENOTES DEPRESSION FOR
WALL/DOOR OPENING (-8" U.N.O.)
INDICATES PIER MARK
INDICATES PIER
INDICATES COLUMN
INDICATES CONCRETE FOOTING
INDICATES SPREAD FOOTING MARK
INDICATES NEW GRID DESIGNATION
(HEXAGON SHAPE AT EXISTING GRID)
TOF
96'-0"
TOW
100'-0"
SF1
A
F1
P1
FOUNDATION PLAN
FRAMING PLAN
INDICATES BEAM FRAMING OVER HOLLOW
STRUCTURAL SECTION (HSS) COLUMN
INDICATES BEAM FRAMING
OVER WIDE FLANGE (WF) COLUMN
INDICATES BRACING CONNECTED TO BEAM
(BELOW FRAMING MEMBER)
INDICATES BEAM FRAMING
INTO SIDE OF COLUMN
INDICATES MOMENT CONNECTION
W x
(0
[1 k
(0 .7
INDICATES REQUIRED UPWARD CAMBER
IN BEAM (INCHES)
INDICATES BEAM SIZE
INDICATES TOP OF STEEL ELEVATION
INDICATES NUMBER OF 3/4" x 5" SHEAR STUDS
FULLY WELDED TO TOP OF BEAM PER 1/2-SPAN
INDICATES CONNECTION DESIGNED BY FABRICATOR
TO DELIVER 46k VERTICAL LOAD TO CENTERLINE
OF COLUMN OR CONNECTION MEMBER
INDICATES TYPICAL BEAM SHEAR SPLICE
INDICATES BEAM FRAMING INTO SIDE OF BEAM
INDICATES BEAM FRAMING OVER BEAM
MASONRY NOTES
MATERIAL PROPERTIES (U.N.O.)
COMPRESSIVE STRENGTH - F'm = 1500 PSI MASONRY REINFORCEMENT - Fy = 60 KSI (A615 GR 60)
MORTAR - TYPE S (ASTM C270)
GROUT AT 28-DAYS - 2500 PSI (ASTM C476)
M-1. ALL MASONRY WALLS ARE TO HAVE 9 GAUGE HORIZONTAL JOINT
REINFORCEMENT WHICH DOES NOT EXCEED 16 INCHES ON CENTER
VERTICALLY.
M-2. ALL LAPS SHALL BE 50 BAR DIAMETERS UNLESS NOTED OTHERWISE.
M-3. HOLLOW MASONRY UNITS SHALL BE LAID WITH FULL HEAD JOINTS AND FULL
BED JOINTS OF THE FACE SHELLS AND UNDER WEBS WHERE THE ADJACENT
CELLS ARE TO BE FILLED WITH GROUT AND AT THE BOTTOM COURSE.
M-4. GROUT SOLID ALL JAMBS IN ALL MASONRY WALLS FULL HEIGHT TO
UNDERSIDE OF LINTEL. EXTEND GROUTED JAMB FROM FACE OF MASONRY
OPENING AT LEAST 24" (A MINIMUM OF 3 CELLS). AT OTHER BEAM BEARING
LOCATIONS, GROUT SOLID A MINIMUM 24"x24" AREA BENEATH THE BEARING
PLATE, UNLESS NOTED OTHERWISE.
M-5. PROVIDE CORNER SPLICE BARS FOR ALL BOND BEAMS OCCURRING AT
CORNERS OR WALL INTERSECTIONS. SPLICE BAR TO BE THE SAME SIZE AS
BARS IN THE BOND BEAM.
M-6. WHERE MASONRY IS APPLIED ADJACENT TO STEEL MEMBERS (BEAMS AND
COLUMNS) PROVIDE ANCHORING DEVICES PER SPECIFICATIONS.
M-7. REFER TO ARCHITECTURAL PLANS AND DOOR/FRAME SCHEDULES FOR
LINTEL ROUGH OPENING LOCATIONS, SIZES, AND ELEVATIONS.
M-8. USE SLEEVE TYPE EXPANSION ANCHORS IN NON-STRUCTURAL CMU WALL
PARTITIONS, UNLESS NOTED OTHERWISE.
M-9. ALL NON-STRUCTURAL CMU WALLS SHALL BE REINFORCED WITH A MINIMUM
#5 VERTICAL BAR AT 48" O.C. WITH THAT CMU CORE GROUTED AND
HORIZONTAL JOINT REINFORCEMENT AT 16" O.C. THE BOTTOM TWO
COURSES SHALL BE GROUTED SOLID. PROVIDE A CONTINUOUS BOND BEAM
AT TOP OF WALL WITH (2) #5 BARS CONTINUOUS, GROUT BOND BEAM SOLID.
PROVIDE #5 DOWEL AT 48" O.C., INTO FOOTINGS.
M-10. REFER TO STRUCTURAL AND/OR ARCHITECTURAL DRAWINGS FOR CONTROL
JOINT LOCATIONS. WHERE CMU CONTROL JOINT LOCATIONS ARE NOT
INDICATED, PROVIDE THEM AT 25' MAXIMUM CENTERS; SUBMIT CMU
CONTROL JOINT LAYOUT TO THE ENGINEER FOR APPROVAL.
M-11. MASONRY DESIGN IS BASED ON INSPECTED WORKMANSHIP.
M-12. PROVIDE HOT AND COLD WEATHER PROCEDURES AND TEMPORARY
MOISTURE PROTECTION IN ACCORDANCE WITH ACI RECOMMENDATIONS
AND PROJECT SPECIFICATIONS.
M-13. PROVIDE HORIZONTAL BOND BEAMS (DIAPHRAGM CHORDS) WITH
(2) #5 BARS CONTINUOUS, BENEATH FLOOR/ROOF MEMBER BEARING
ELEVATIONS AND AT DECK EDGE.
M-14. MASONRY SHALL BE PLACED IN ONE-HALF RUNNING BOND UNLESS NOTED
OTHERWISE.
M-15. UNLESS DETAILED OTHERWISE, PROVIDE 10 GAGE BENT SLIP JOINT
PLATES 4" x 4" x 1'-0" LONG AT 3'-0" O.C. EACH SIDE OF THE TOP OF ALL
NON-STRUCTURAL MASONRY WALLS. ATTACH TO UNDERSIDE OF METAL
ROOF DECK OR STRUCTURAL STEEL WITH 3 (MIN.) SELF-DRILLING, SELF-
THREADING SCREWS (#12) AS REQUIRED BY THICKNESS OF BASE METAL.
ATTACH TO UNDERSIDE OF CONCRETE DECK WITH 3 (MIN.) SELF-TAPPING
CONCRETE SCREWS 3/16" DIA. SEE ARCHITECTURAL DRAWINGS FOR
NON-STRUCTURAL MASONRY WALL LOCATIONS. MAINTAIN 1" (MINIMUM)
GAP BETWEEN TOP OF MASONRY WALL AND BOTTOM OF STRUCTURE.
DO NOT ATTACH PLATES TO MASONRY WALL.
L#
FOUNDATION WALL DESIGNATIONFW08
INDICATES KNEE BRACING CONNECTED TO BEAM
(BELOW FRAMING MEMBER)
INDICATES COLLECTOR CONNECTION
STRUCTURAL STEEL NOTES
MATERIAL PROPERTIES (U.N.0.)
W-SHAPES - Fy = 50 KSI (A992 OR A572 Gr 50) C-SHAPES & ANGLES - Fy = 36 KSI (A36) PLATES & BARS - Fy = 36 KSI (A36) RECTANGULAR HSS - Fy = 46 KSI (A500 Gr B) ROUND HSS - Fy = 42 KSI (A500 Gr B) PIPE - Fy = 35 KSI (A53 Gr B) RODS - Fy = 36 KSI (A36)
S-1. STEEL BEAMS WITH RESIDUAL CAMBER RESULTING FROM MILL FABRICATION
OR ROLLING SHALL BE SHOP FABRICATED AND ERECTED SUCH THAT THIS
RESIDUAL CAMBER COUNTERACTS GRAVITY LOAD DEFLECTION.
S-2. UNLESS NOTED OTHERWISE, ALL BOLTED CONNECTIONS SHALL UTILIZE
3/4 INCH DIAMETER A325 BOLTS TIGHTENED TO THE SNUG-TIGHT CONDITION.
THE SNUG-TIGHT CONDITION IS DEFINED BY THE RCSC'S "SPECIFICATION
FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS".
S-3. ALL ANCHOR BOLTS ARE TO BE 1 INCH DIAMETER F1554 Gr. 36 THREADED
RODS UNLESS NOTED OTHERWISE. (2)-1/2 INCH DIAMETER ANCHOR BOLTS
SHALL BE PROVIDED AT ALL BEAM AND LINTEL BEARINGS ON CONCRETE
OR MASONRY.
S-4. U.N.O., POST INSTALLED ANCHORS ARE TO BE HILTI HIT-HY 200-R ADHESIVE
ANCHORS FOR CONCRETE BASE MATERIAL AND HILTI HIT-HY 70 ADHESIVE
ANCHORS FOR CONCRETE MASONRY BASE MATERIAL AS MANUFACTURED
BY HILTI FASTENING SYSTEMS OF TULSA, OKLAHOMA OR EQUAL. INSTALL
ANCHORS WITH EMBEDMENT DEPTHS INDICATED.
S-5. STUD ANCHORS ARE TO BE NELSON STUDS OR EQUAL (ASTM A108).
S-6. BEAM AND LINTEL PLATES SHALL BE FULLY GROUTED WITH A MINIMUM
1/2" NON-SHRINK GROUT.
S-7. ALL WELDING OF NEW STEEL IS TO BE WITH E70XX ELECTRODES, UNLESS
NOTED OTHERWISE. WELDING SHALL BE IN ACCORDANCE WITH THE LATEST
AWS SPECIFICATIONS BY CERTIFIED WELDERS.
S-8. WHEN FIELD WELDING TO EXISTING STEEL, ADJUST WELDING PROCEDURES
AS REQUIRED TO BE COMPATIBLE WITH THE NEW AND EXISTING STEEL.
S-9. STEEL CONNECTIONS NOT DETAILED ON THE PLANS ARE TO BE THE
FABRICATOR'S STANDARD AND ARE TO BE SELECTED AND DESIGNED IN
ACCORDANCE WITH AISC ASD SPECIFICATIONS, TYPE 2 FRAMING
CONNECTIONS, FOR THE REACTIONS INDICATED.
MINIMUM NO. BOLTS PER CONNECTION
n = 2 FOR MEMBERS 10 INCHES DEEP OR LESS n = 3 FOR MEMBERS 12, 14, OR 15 INCHES DEEP n = 4 FOR MEMBERS 16 OR 18 INCHES DEEP n = 5 FOR MEMBERS 21 OR 24 INCHES DEEP n = 6 FOR MEMBERS 27 OR 30 INCHES DEEP n = 8 FOR MEMBERS 33 OR 36 INCHES DEEP
S-10. UNLESS NOTED OTHERWISE, THE MINIMUM CONNECTION PLATE/ANGLE
THICKNESS SHALL BE 5/16", THE MINIMUM WELD 1/4", AND THE MINIMUM
DESIGN LOAD ON ANY CONNECTION 10 KIPS.
S-11. ALL CONNECTIONS TO PIPE AND TUBE COLUMNS SHALL BE THROUGH
PLATE CONNECTIONS UNLESS OTHERWISE INDICATED.
S-12. THE CONTRACTOR SHALL FURNISH AND INSTALL MISCELLANEOUS STEEL
(CURBS, HANGERS, BRACING, ETC.) AS INDICATED AND AS NECESSARY
PER ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS.
S-13. ALL EXTERIOR MASONRY SHELF ANGLES, LINTEL BEAMS, AND LINTEL
PLATES SHALL BE HOT DIPPED GALVANIZED ACCORDING TO ASTM A123.
STRUCTURAL TESTING AND INSPECTION
TI-1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT ALL STRUCTURAL
WORK FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS. ANY
STRUCTURAL INSPECTION PROVIDED BY OTHERS DOES NOT RELIEVE THE
CONTRACTOR OF THIS RESPONSIBILITY. ANY STRUCTURAL DEVIATIONS
FROM THE CONTRACT DOCUMENTS THAT ARE FOUND AT A LATER DATE
AND ARE DECLARED TO BE SIGNIFICANT BY THE STRUCTURAL ENGINEER
SHALL BE CORRECTED BY THE CONTRACTOR WITHOUT COST OR ANY
DELAY TO THE PROJECT SCHEDULE.
TI-2. THE CONTRACTOR SHALL RETAIN AN INDEPENDENT TESTING AGENCY TO
PROVIDE FIELD AND LAB TESTING OF CONSTRUCTION MATERIALS AND TO
PROVIDE CONSTRUCTION INSPECTIONS. THE CONSTRUCTION INSPECTION
SHALL BE DONE BY QUALIFIED INSPECTORS THAT ARE SATISFACTORY TO
THE CONTRACTING OFFICER'S REPRESENTATIVE.
TI-3. THE CONTRACTOR SHALL PROVIDE THE TESTING AND INSPECTING AGENCY
ACCESS TO ALL PLACES WHERE THE WORK IS BEING PERFORMED. A
MINIMUM OF 24 HOURS NOTIFICATION SHALL BE GIVEN TO THE TESTING
AGENCY AND CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO THE
COMMENCEMENT OF WORK REQUIRING TESTING OR INSPECTION.
TI-4. THE TESTING AGENCY IS NOT AUTHORIZED TO DIRECT OR APPROVE ANY
CHANGES FROM THE CONTRACT DOCUMENTS. IF THE CONTRACTOR WISHES
TO QUESTION THE TESTING AGENCY'S INTERPRETATION OF THE CONTRACT
DOCUMENTS, THEY MAY DO SO DIRECTLY WITH THE CONTRACTING
OFFICER'S REPRESENTATIVE.
TI-5. THE TESTING AGENCY IS NOT AUTHORIZED TO STOP OR DELAY THE WORK.
IF THE CONTRACTOR ELECTS TO CONTINUE WITH A CERTAIN PORTION OF
WORK AFTER BEING NOTIFIED BY THE TESTING AGENCY THAT SUCH WORK
IS NOT IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS, THE
CONTRACTOR DOES SO AT THEIR OWN RISK AND MAY BE REQUIRED TO
CORRECT THE WORK AT A LATER DATE.
TI-6. THE TESTING AND INSPECTING AGENCY IS NOT INSPECTING FOR O.S.H.A.
COMPLIANCE OR REQUIRED TO INSPECT TEMPORARY CONSTRUCTION,
SUCH AS TEMPORARY BRACING. TEMPORARY CONSTRUCTION IS THE
CONTRACTOR'S SOLE RESPONSIBILITY.
TI-8. TESTING AND INSPECTION IS NOT REQUIRED FOR WORK PERFORMED AT AN
OFF-SITE FABRICATION SHOP, UNLESS SPECIFICALLY NOTED OR SPECIFIED
OTHERWISE.
TI-9. THE PROJECT SPECIFICATIONS TYPICALLY INDICATE THE FREQUENCY OF
CONSTRUCTION TESTING AND INSPECTIONS. WHERE THE FREQUENCY IS
NOT INDICATED, THE TESTING AGENCY SHALL SUBMIT A PROPOSAL OF
INSPECTION INTERVALS TO THE CONTRACTING OFFICER'S REPRESENTATIVE.
TI-10. THE TESTING AND INSPECTING AGENCY SHALL ISSUE ONGOING REPORTS OF
INSPECTIONS AND TESTS TO THE CONTRACTOR, ENGINEER, AND ARCHITECT
OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN IF
UNCORRECTED, TO THE CONTRACTING OFFICER'S REPRESENTATIVE.
TI-11. INSPECTION AGENCY SHALL INSPECT FOR CONFORMANCE TO SPECIFIED
REQUIREMENTS FOR PROTECTING NEW CONCRETE AND MASONRY FROM
THE ADVERSE EFFECTS OF WEATHER, HEATING EQUIPMENT AND OTHER
POTENTIALLY HARMFUL CONDITIONS.
TI-12. CONSTRUCTION TESTING AND INSPECTION BY THE TESTING AND INSPECTING
AGENCY IS REQUIRED AS FOLLOWS:
A. CONCRETE TESTING PER THE SPECIFICATIONS.
B. CONCRETE INSPECTION SHALL INCLUDE THE PLACEMENT OF
REINFORCEMENT. REINFORCING BAR SIZES, SPACING, TIES, LAPS,
AND COVER.
C. MASONRY TESTING PER THE SPECIFICATIONS.
D. MASONRY INSPECTION SHALL INCLUDE THE PLACEMENT OF
REINFORCEMENT. REINFORCING BAR SIZES, SPACING, AND LAPS.
E. INSPECTION OF FIELD WELDED MOMENT CONNECTIONS SHALL INCLUDE
VISUAL AND/OR ULTRASONIC TESTING, AT THE TESTING AGENCY'S
OPTION. ALL OTHER FIELD WELDED CONNECTIONS SHALL BE VISUALLY
INSPECTED AT A MINIMUM. THE WELDER'S CERTIFICATION SHALL ALSO
BE VERIFIED.
F. FIELD BOLTING INSPECTIONS SHALL INCLUDE VISUAL INSPECTION OF
ALL THE CONNECTIONS RELATED TO STRUCTURAL STEEL. THE SIZE,
TYPE, AND QUANTITY OF BOLTS AND THEIR INSTALLATION SHALL BE
INSPECTED. WHERE SLIP-CRITICAL OR PRE-TENSIONED BOLTS ARE
SPECIFIED, PRE-TENSIONING OF BOLTS SHALL BE VERIFIED BY TESTING.
TI-13. SPECIAL STRUCTURAL INSPECTIONS ARE REQUIRED AS FOLLOWS
PER 2015 INTERNATIONAL BUILDING CODE:
A. STEEL CONSTRUCTION - PER TABLE 1705.2
B. CONCRETE CONSTRUCTION - PER TABLE 1705.3
C. MASONRY CONSTRUCTION - PER SECTION 1705.4
D. SOILS - PER SECTION 1705.6
E. PILE / PIER FOUNDATIONS - PER SECTION 1705.7 / 1705.8
STEEL BAR JOISTS
MATERIAL PROPERTIES (U.N.0)
COMPLY WITH SJI'S "SPECIFICATIONS" FOR WEB AND STEEL-ANGLE CHORD
MEMBERS.
J-1. BAR JOISTS SHALL BE DESIGNED TO RESIST FORCES INDICATED ON
DRAWINGS AND SPECIFICATIONS.
J-2. TYPICAL BAR JOISTS ARE NOT DESIGNED FOR CONCENTRATED LOADS.
PLACE LOADS AT PANEL POINTS OR WELD ADDITIONAL DOUBLE ANGLE
MEMBERS ONE EACH SIDE FROM POINT OF CONCENTRATED LOAD TO
THE NEAREST PANEL POINT ON THE OPPOSITE CHORD.
J-3. ALL FIELD MODIFICATIONS OR REPAIRS TO THE JOIST, OR JOIST GIRDERS,
SHALL BE APPROVED BY THE JOIST MANUFACTURER IN WRITING. THIS
LETTER SHALL BE FORWARDED TO THE ENGINEER FOR REVIEW.
J-4. CUTTING & DRILLING OF CHORD OR WEB MEMBERS IN BAR JOISTS, OR
JOIST GIRDERS, IS NOT PERMITTED.
J-5. ALL BRIDGING SHALL BE EQUALLY SPACED, UNLESS NOTED OTHERWISE,
BY JOIST MANUFACTURER.
J-6. CONTRACTOR(S) SHALL PROVIDE MEANS FOR ADEQUATE DISTRIBUTION
OF CONSTRUCTION LOADS SO THAT CARRYING CAPACITY OF ANY BAR
JOIST, JOIST GIRDER, OR OTHER STRUCTURAL MEMBER IS NOT EXCEEDED.
J-7. JOIST SHALL BE CONSIDERED AS UNSTABLE DURING ERECTION. UNDER
NO CIRCUMSTANCES ARE CONSTRUCTION LOADS OF ANY DESCRIPTION TO
BE PLACED ON UNBRIDGED JOISTS. THE APPLICATION OF CONSTRUCTION
LOADS ON UNBRIDGED JOISTS IS IN DIRECT VIOLATION OF O.S.H.A.
REGULATIONS.
J-8. WHERE X-BRIDGING INTERFERES WITH MECHANICAL PIPING OR DUCTWORK,
UTILIZE HORIZONTAL BRIDGING AS DIRECTED BY JOIST MANUFACTURER.
J-9. ALL BRIDGING SHALL BE PER SJI AND AS REQUIRED FOR DESIGN LOADS.
J-10. PROVIDE JOIST WITH UPLIFT CAPACITY AS REQUIRED BY THE BUILDING
CODE AND THE STRUCTURAL DESIGN CRITERIA.
SHOP DRAWINGS
SD-1. SHOP DRAWINGS SHALL BE SUBMITTED FOR STRUCTURAL ITEMS AS
REQUIRED BY THE SPECIFICATIONS. CONSTRUCTION DOCUMENTS
SHALL NOT BE REPRODUCED FOR USE AS SHOP DRAWINGS.
SD-2. THE GENERAL CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS
AND PRODUCT DATA FOR CONFORMANCE WITH THE CONSTRUCTION
DOCUMENTS PRIOR TO SUBMITTAL. REVIEWED SUBMITTALS SHALL BE
STAMPED BY THE CONTRACTOR. ANY SHOP DRAWING OR PRODUCT
DATA NOT REVIEWED AND STAMPED BY THE GENERAL CONTRACTOR
WILL BE REJECTED. GENERAL CONTRACTOR SHALL CLOUD OR FLAG ALL
ITEMS NOT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND
SHALL VERIFY ALL DIMENSIONS.
SD-3. ANY CHANGES, SUBSTITUTIONS OR DEVIATIONS FROM THE ORIGINAL
CONTRACT DRAWINGS SHALL BE CLOUDED BY THE MANUFACTURER OR
FABRICATOR. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS WHICH
ARE CLOUDED OR FLAGGED BY SUBMITTING PARTIES SHALL NOT BE
CONSIDERED APPROVED AFTER THE ENGINEER'S REVIEW, UNLESS
SPECIFICALLY NOTED ACCORDINGLY BY THE CONTRACTING OFFICER'S
REPRESENTATIVE.
SD-4. THE APPROVED SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL
CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY
ARE NOT TO BE CONSIDERED CHANGES TO THE ORIGINAL CONTRACT
DRAWINGS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE
THAT ITEMS OMITTED OR SHOWN INCORRECTLY ARE CONSTRUCTED
IN ACCORDANCE WITH THE CONTRACT DRAWINGS.
SD-5. SHOP DRAWING REVIEW IS INTENDED ONLY FOR GENERAL CONFORMANCE
TO THE DESIGN CONCEPT AND CONSTRUCTION DOCUMENTS.
SD-6. SHOP DRAWINGS WILL BE RETURNED FOR RESUBMITTAL IF MAJOR ERRORS
ARE FOUND DURING REVIEW.
SD-7. ALLOW A MINIMUM OF (10) WORKING DAYS FOR REVIEW OF SHOP DRAWINGS
BY THE CONTRACTING OFFICER'S REPRESENTATIVE.
STRUCTURAL DESIGN CRITERIA
1. GOVERNING CODE: UFC 3-301-01 WITH 2016 AMENDMENTS AND IBC 2015
2. RISK CATEGORY: CATEGORY III
3. FLOOR LIVE LOAD (1603.1.1)
ACCESS FLOORS: 100 PSF
WALK-ON CEILINGS: 20 PSF
OFFICE FLOORS: 100 PSF
SIMULATOR LOADING: 250 PSF
4. ROOF LIVE LOAD (1603.1.2)
MINIMUM ROOF LIVE LOAD: 20 PSF
5. ROOF SNOW LOAD (1603.1.3)
GROUND SNOW LOAD: PG = 35 PSF
FLAT-ROOF SNOW LOAD: PF = 21 PSF
SNOW EXPOSURE FACTOR: CE = 0.9
SNOW LOAD IMPORTANCE FACTOR: IS = 1.1
THERMAL FACTOR: CT = 1.0
DRIFT SURCHARGE LOAD: PD = 32 PSF
WIDTH OF SNOW DRIFTS: W = 7 FEET
6. WIND DESIGN DATA (1603.1.4)
ULTIMATE WIND SPEED (3-SECOND GUST): VULT = 120 MPH
NOMINAL WIND SPEED (3-SECOND GUST) VASD = 93 MPH
WIND EXPOSURE: FULLY EXPOSED
INTERNAL PRESSURE COEFFICIENT: GCPI = +/- 0.18
7. EARTHQUAKE DESIGN DATA (1603.1.5)
IMPORTANCE FACTOR: IE = 1.25
MAPPED, MCE, 5% DAMPED, SPECTRAL ACCELERATIONS:
AT SHORT PERIODS: SS = 8% G
AT A PERIOD OF 1 SECOND: S1 = 5% G
SITE CLASS: E
DESIGN EARTHQUAKE SPECTRAL ACCELERATIONS
AT SHORT PERIODS: SDS = 0.085 G
AT A PERIOD OF 1 SECOND: SD1 = 0.080 G
OFFICE ADDITION:
SEISMIC DESIGN CATEGORY: SDC = B
BASIC SEISMIC-FORCE-RESISTING-SYSTEM:SFRS = OMF (TABLE 12.2-1)
DESIGN BASE SHEAR: VS = 0.6 KIPS
SEISMIC RESPONSE COEFFICIENTS: CS = 0.0324
RESPONSE MODIFICATION FACTOR: R = 3.5
ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
SIMULATOR ADDITION:
SEISMIC DESIGN CATEGORY: SDC = B
BASIC SEISMIC-FORCE-RESISTING-SYSTEM:SFRS = ORMSW
DESIGN BASE SHEAR: VS = 8.6 KIPS
SEISMIC RESPONSE COEFFICIENTS: CS = 0.0567
RESPONSE MODIFICATION FACTOR: R = 2
ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
8. GEOTECHNICAL DESIGN DATA (1603.1.6)
NET ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF PER
SOILS & ENGINEERING SERVICES, INC. GEOTECHNICAL REPORT.
PROJECT #12674.31 R01, DATED 07/26/16.
9. FLOOD DESIGN DATA (1603.1.7)
BUILDING IS NOT LOCATED IN FLOOD HAZARD AREA; THEREFORE FLOOD
DESIGN DATA IS NOT REQUIRED
10. SPECIAL LOADS (1603.1.8)
SPECIAL LOADING CONDITIONS ARE NOT APPLICABLE TO THE DESIGN OF
THIS BUILDING; THEREFORE SPECIAL LOADS ARE NOT REQUIRED
11. SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE (1603.1.9)
BUILDING IS DESIGNATED SEISMIC DESIGN CATEGORY B; THEREFORE
SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE ARE NOT REQUIRED.
12. STRUCTURAL OBSERVATIONS FOR SEISMIC AND/OR WIND RESISTANCE
SEE DESIGN CRITERIA LISTED ABOVE FOR BASIC WIND SPEED AND
SEISMIC DESIGN CATEGORY.
STRUCTURAL OBSERVATIONS FOR WIND RESISTANCE REQUIRED FOR RISK
CATEGORY III OR IV OR WHEN BUILDING HEIGHT EXCEEDS 75 FEET WHEN
Vasd EXCEEDS 110 MPH.
STRUCTURAL OBSERVATIONS FOR SEISMIC RESTANCE REQUIRED FOR RISK
CATEGORY III OR IV OR WHEN BUILDING HEIGHT EXCEEDS 75 FEET WHEN
THE STRUCTURE IS ASSIGNED TO A SEISMIC DESIGN CATEGORY D, E, OR F.
COLD FORMED STEEL FRAMING NOTES
CF-1. COLD FORMED STEEL WORK SHALL CONFORM TO THE 2012 EDITION
(INCLUDING ALL APPLICABLE SUPPLEMENTS AND STANDARDS) OF AISI'S
"NORTH AMERICAN SPECIFICATION OF FOR THE DESIGN OF COLD-FORMED
STEEL STRUCTURAL MEMBERS"
CF-2. REFER TO SPECIFICATIONS FOR COLD FORMED METAL FRAMING MATERIAL
PROPERTIES AND OTHER GENERAL REQUIREMENTS. COLD FORMED STEEL
SHALL BE GALVANIZED G-60 UNLESS NOTED OTHERWISE.
CF-3. STUD, TRACK, AND OTHER APPLICABLE ROLLED SHAPES SHALL CONFORM
TO THE NOMENCLATURE AND DIMENSIONS SET FORTH BY THE STEEL STUD
MANUFACTURER'S ASSOCIATION (SSMA). REFER TO SSMA'S "PRODUCT
TECHNICAL INFORMATION" CATALOG AND ICC ER 4943P FOR MINIMUM
SECTION PROPERTIES AND DIMENSIONS.
CF-4. SCREWS FOR ATTACHING COLD FORMED STEEL TO COLD FORMED STEEL
SHALL BE CORROSION RESISTANT, SELF DRILLING, SELF TAPPING, #8 OR
#10 AS SPECIFIED, PAN OR HEX HEAD, WITH LENGTH, POINT STYLE AND
INSTALLATION METHOD IN ACCORDANCE WITH MANUFACTURERS
INSTRUCTIONS. PROVIDE 3/4" MINIMUM SPACING BETWEEN SCREWS AND
3/4" MINIMUM EDGE DISTANCE UNLESS NOTED OTHERWISE.
CF-5. ALL CONNECTIONS SHALL HAVE AT LEAST (2) #8 SCREWS UNLESS NOTED
OTHERWISE.
CF-6. FASTENERS FROM COLD FORMED STEEL TO STRUCTURAL STEEL OR
CONCRETE SHALL BE 0.157" DIAMETER POWDER DRIVEN FASTENERS
"SHOT PINS" UNLESS OTHERWISE NOTED. USE HILTI "X-U" OR EQUIVALENT
FASTENERS WITH 1" EMBEDMENT INTO CONCRETE WITH WASHERS PER
MANUFACTURER, UNLESS NOTED OTHERWISE. SIZE LENGTH OF SHOT PINS
AS REQUIRED BY MANUFACTURER'S ICC ES REPORT FOR ATTACHMENT TO
STRUCTURAL STEEL. MANUFACTURER'S EDGE DISTANCE AND SPACING
REQUIREMENTS SHALL BE MET AND VERIFIED BY THE CONTRACTOR IN THE
FIELD.
CF-7. WALL TRACKS AND ACCESSORIES SHALL BE THE SAME GAUGE AND WIDTH
AS THE STUDS, U.N.O.
CF-8. PROVIDE SUFFICIENT STUDS AND BLOCKING/BACKING AT ALL GRAB BARS
AND WALL HUNG EQUIPMENT, MONITORS, CABINETS, TOILET ACCESSORIES,
ETC.
METAL DECK
MATERIAL PROPERTIES (U.N.0)
ROOF DECK: 20 GAUGE, GALVANIZED, Fy = 33 KSI FORM DECK: 20 GAUGE, GALVANIZED, Fy = 33 KSI
MD-1. BUTTON PUNCHING ROOF DECK IS NOT PERMITTED. REFERENCE
DRAWINGS FOR ROOF DECK ATTACHMENT REQUIREMENTS.
STRUCTURAL DIAPHRAGM ACTION IS PROVIDED BY THE ROOF DECK
AND ITS ATTACHMENT.
MD-2. UNLESS NOTED OTHERWISE, ALL MISCELLANEOUS OPENINGS IN METAL
ROOF DECK ARE TO BE FRAMED BY 5x3x3/8" ANGLES. LONG LEG OF
ANGLES SHALL BE VERTICAL. ANGLES SHALL BE WELDED TO THE TOP
CHORD/FLANGE OF ROOF FRAMING AND EACH OTHER.
MD-3. UNLESS NOTED OTHERWISE, METAL DECKING SHALL BE CONTINUOUS
OVER 3 SPANS AND HAVE JOINTS OVER SUPPORTING MEMBERS.
MD-4. CONTRACTOR IS RESPONSIBLE FOR PROVIDING POUR STOPS AT EDGES
OF METAL DECK PER SDI POUR STOP SELECTION TABLE/
RECOMMENDATIONS OR BENT PLATE POUR STOPS AS REQUIRED TO
FORM THE SLAB EDGE.
SCIF GENERAL NOTES:
1. THE VAULT AREA IS CONSIDERED A SENSITIVE COMPARTMENTED
INFORMATION FACILITY. ALL NEW CONSTRUCTION AND RENOVATION TO THE
AREA INCLUDING WALL CONSTRUCTION, FIRE PROTECTION/DETECTION,
MECHANICAL/HVAC, ELECTRICAL, AND TECHNOLOGY SYSTEMS MUST
COMPLY WITH THE REQUIREMENTS PROVIDED IN UNIFIED FACILITY CRITERIA
4-010-05 SENSITIVE COMPARTMENTED INFORMATION FACILITY PLANNING,
DESIGN, AND CONSTRUCTION WITH CHANGE 1, 1 OCTOBER 2013, AND
REFERENCED IC TECH SPEC FOR ICD/ICS 705 TECHNICAL SPECIFICATIONS
FOR CONSTRUCTION AND MANAGEMENT OF SENSITIVE COMPARTMENTED
INFORMATION FACILITIES, VERSION 1.2, DATED 23 APRIL 2012.
2. CONSTRUCTION, GENERAL: UFC 4-010-05 REQUIREMENTS HAVE BEEN
INCORPORATED INTO THE DESIGN DRAWINGS AND SPECIFICATIONS.
CHANGES TO THE SCOPE OF WORK PROVIDED IN THE CONTRACT
DOCUMENTS MAY INVALIDATE THE APPROVALS RECEIVED FOR THIS
CONSTRUCTION, AND COULD RESULT IN THE REMOVAL AND
RECONSTRUCTION OF FINISHED WORK. ANY PROPOSED DEVIATIONS FROM
THE CONTRACT DOCUMENTS MUST BE FULLY REVIEWED AND APPROVED BY
THE COR PRIOR TO IMPLEMENTATION.
3. ALL CONSTRUCTION MUST BE DONE IN SUCH A MANNER AS TO PROVIDE
VISUAL EVIDENCE OF UNAUTHORIZED PENETRATION. CONSTRUCTION MUST
BE COMPLETED IN A MANNER TO PROVIDE THE REQUIRED STC RATINGS FOR
SOUND CONTROL AT THE WALLS IDENTIFIED. THROUGH-WALL
PENETRATIONS OF PIPE, CONDUIT, AND DUCTWORK REQUIRE SPECIAL
CONSTRUCTION AND INSPECTION PROVISIONS WHICH HAVE BEEN
INCORPORATED INTO THE CONTRACT DOCUMENTS.
4. THE CONTRACTOR SHALL SUBMIT A LIST OF ALL MATERIALS USED IN THE
CONSTRUCTION OF THE VAULT AREA, INCLUDING DIMENSIONAL EXTENTS OF
THE USE AND LOCATION(S) WHERE USED IN THE VAULT. THIS LIST SHALL BE
KEPT UP TO DATE DURING THE COURSE OF CONSTRUCTION AND SUBMITTED
TO THE COR AS PART OF THE CLOSE-OUT REQUIREMENTS AT THE END OF
CONSTRUCTION.
5. PHOTOGRAPHY REQUIREMENTS: THE CONTRACTOR IS NOT ALLOWED TO
HAVE PHOTOGRAPHIC OR RECORDING DEVICES IN THE VAULT AREA. 115 FW
CCZ PERSONNEL WILL BE TAKING PICTURES OF ON-GOING CONSTRUCTION
IN ORDER TO DOCUMENT THAT ALL SECURITY MEASURES ARE BEING MET.
THE COR SHALL BE NOTIFIED AT LEAST ONE WORKING DAY PRIOR TO KEY
CONSTRUCTION MILESTONES. KEY CONSTRUCTION MILESTONES INCLUDE
BUT ARE NOT LIMITED TO: WALL CONSTRUCTION, INCLUDING EACH OF
MULTIPLE LAYERS OF GYPSUM BOARD, FINISHING OF PENETRATIONS,
NON-CONDUCTIVE BREAKS OF PENETRATIONS, AND SOUND BATT
INSULATION INSTALLATIONS.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/3
/2
:0
:3
P M
C R e v it L o c a l\
-1
.0
-S -C e n tr a l-m je
.r v t
W
IS
C O
N S
IN
A
IR
N
A T
IO
N
A L G
U A
R D
T R
U A
X F
IE
L D
A N
G B
M A
D
IS
O N
W
I
A D
A L B
S-001
STRUCTURAL NOTES
XGFG132020ANG NO.:
3141300-141489.01
MJE
DRM
May 4, 2017
ZJE
B.O. = BOTTOM OF ________
BP# = BASE PLATE TYPE
BRG = BEARING
C TO C = CENTER TO CENTER
CCJ = CONSTRUCTION CONTROL JOINT
CJ = CONTROL JOINT
CLSM = CONTROLLED LOW STRENGTH MATERIAL ("FLOWABLE FILL")
CONT = CONTINUOUS
DBLT = DOUBLE-TEE
DIA = DIAMETER
DTB = DOUBLE-TEE BEARING
EF = EACH FACE
EL = ELEVATION
EW = EACH WAY
F# = SPREAD FOOTING TYPE
FDTN = FOUNDATION
FV = FIELD VERIFY
GALV = GALVANIZED
HPC = HIGH PERFORMANCE COATING
JB = JOIST BEARING
LLH = LONG LEG HORIZONTAL
LLV = LONG LEG VERTICAL
NIC = NOT IN CONTRACT
NTS = NOT TO SCALE
OC = ON CENTER
P# = PIER TYPE
PCB = PRECAST BEARING (ELEVATION)
PRCST = PRECAST
Rxn = REACTION
SF# = STRIP FOOTING TYPE
SIM = SIMILAR
SST = STAINLESS STEEL
STL = STEEL
T.O. = TOP OF ________
TBD = TO BE DETERMINED
TOC = TOP OF COLUMN
TOF = TOP OF FOOTING
TOL = TOP OF LEDGE
TOP = TOP OF PIER
TOS = TOP OF STEEL
TOW = TOP OF WALL
TPC = TOP OF PRECAST
TSL = TOP OF SLAB
TYP = TYPICAL
UNO = UNLESS NOTED OTHERWISE
WWF = WELDED WIRE FABRIC/REINFORCEMENT
05/04/17 TYPE B3
FOUNDATION
PLAN GENERAL NOTES:
1. SITE DATUM OF FINISHED FIRST FLOOR INDICATED ON CIVIL SITE PLAN =
ELEVATION 100'-0" ON STRUCTURAL DRAWINGS.
2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE
ATTENTION OF THE ARCHITECT/ENGINEER FOR FINAL DECISION.
3. REFER TO SHEET S-001 FOR STRUCTURAL LEGENDS, ABBREVIATIONS,
AND SYMBOLOGY.
4. REFER TO SHEET S-501 FOR TYPICAL DETAILS NOT REFERENCED ON
THIS SHEET.
5. TOP OF FOOTING ELEVATION = 94'-0" UNLESS NOTED OTHERWISE.
6. TOP OF FOUNDATION WALL ELEVATION = 100'-0" UNLESS NOTED
OTHERWISE.
7. STRIP FOOTINGS SHALL BE CENTERED UNDER FOUNDATION/MASONRY
WALLS UNLESS NOTED OTHERWISE.
8. SPREAD FOOTINGS:
F2A 2'-2" WIDE X 5'-0" LONG X 1'-0" DEEP
(3) #5 LONGITUDUNAL BARS, TOP AND BOTTOM
(5) #5 TRANSVERSE BARS, TOP AND BOTTOM
F4 4'-0" WIDE X 4'-0" LONG X 1'-0" DEEP
(4) #5 BARS EACH WAY, TOP AND BOTTOM
1 1
2 2
3 3
5 5
6 6
8 8
9 9
10 10
11 11
12 12
13 13
14 14
16 16
17 17
21 21
23 23
24 24
A
A
B
B
C
C D E
G
G
H J K L M
M
N
P Q
R S TF
23' - 8" ADDITION 160' - 0" EXISTING BUILDING
23.9
S.1Q.1
19.5
61' - 8" ADDITION 84' - 0" EXISTING BUILDING 26' - 4 1/2" ADDITION
A D
D
IT
IO
N
9 1/2" 12' - 2 1/2" 15' - 9 1/2" 33' - 4" 4' - 1" 27' - 7" 4' - 1" 33' - 4" 15' - 9 1/2" 12' - 2 1/2" 9 1/2"
28' - 0" 35' - 0" 4' - 0" 26' - 0" 4' - 0" 35' - 0" 28' - 0"
24' - 5 1/2" 12' - 2 1/2" 15' - 9 1/2" 10' - 0" 14' - 2 1/2" 13' - 2 1/2" 27' - 7" 13' - 2 1/2" 14' - 2 1/2"
9 1/2"
5" 25' - 1" 10 1/2"
29' - 0" 26' - 0" 29' - 0"
E X
IS
T
IN
G
B U
IL
D
IN
G
/2
"1
/2
/2
/2
F2A
F2A
F2A
F4
F4
F4
E X
T O
F
T O
F
TOF
94' - 0"
EX TOF
94' - 0"
S-501
S-501
P
P
P
P
P
P
TOF
94' - 0"
EX TOF
94' - 0"
EX TOF
94' - 0"
TOF
94' - 0"
TOF
99' - 4"
T O
F
TOW
100' - 0"
TOL
99' - 4"
TYP
TYP
T O
W
T O
W A
T D
O O
R 28' - 0" 10' - 0"
TOW
100' - 0"
TOL
99' - 4"
TOW
99' - 4"
TOW
AT DOOR
TYP
TYP
3.001
3.001
3.001
3.004
3.004
TOF
94' - 0"
3.001
S-501
S-501
S-501
S-501
8' - 0"
5' - 0"
4' - 0"
5' - 0"
S-501
T O
F
E X
T O
F
/4
TOF
94' - 0"
EX TOF
94' - 0"
S-501
S-511
8"
3.201
3.203
3.201
3.201
5' - 0"
3.201
S-501
S-501
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/3
/2
:0
:5
P M
C R e v it L o c a l\
-1
.0
-S -C e n tr a l-m je
.r v t
W
IS
C O
N S
IN
A
IR
N
A T
IO
N
A L G
U A
R D
T R
U A
X F
IE
L D
A N
G B
M A
D
IS
O N
W
I
A D
A L B
S-101
FOUNDATION PLAN
XGFG132020ANG NO.:
3141300-141489.01
MJE
DRM
May 4, 2017
ZJE
KEYED NOTES
3.001 REMOVE 8" DEEP PORTION OF EXISTING CONCRETE FOUNDATION
WALL UNDER NEW DOOR (SEE ARCHITECTURAL).
3.004 REMOVE 8" DEEP PORTION OF EXISTING CONCRETE FOUNDATION
WALL UNDER NEW DOOR (SEE ARCHITECTURAL). EXTEND
DEMOLITION 4" PAST NEW HSS COLUMN FOR BASE PLATE
ANCHORAGE, SEE DETAIL 13/S-541.
3.201 NEW CONCRETE STOOP, SEE DETAILS 7/S-511 AND 8/S-511.
3.203 NEW CONCRETE STAIR, SEE DETAIL 13/S-511
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"1
FOUNDATION PLAN
1. SITE DATUM OF FINISHED FIRST FLOOR INDICATED ON CIVIL SITE PLAN =
ELEVATION 100'-0" ON STRUCTURAL DRAWINGS.
2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE
ATTENTION OF THE ARCHITECT/ENGINEER FOR FINAL DECISION.
3. REFER TO SHEET S-001 FOR STRUCTURAL LEGENDS, ABBREVIATIONS,
AND SYMBOLOGY.
4. REFER TO SHEET S-511 FOR TYPICAL DETAILS NOT REFERENCED ON
THIS SHEET.
5. REFER TO DETAIL 1/S-511 FOR STRUCTURAL SLAB TYPES.
6. FLOAT AND TROWEL FLOOR SLABS PER REQUIREMENTS OF ARCH.
FLOOR FINISH SYSTEM.
7. (2) DASHED LINES INDICATE (2) ADDITIONAL #4 BARS
(5'-0" LONG) DIAGONAL 6" FROM CORNER IN SLAB, 2" CLEAR FROM
TOP OF SLAB.
FLATWORK
PLAN GENERAL NOTES:
1 1
2 2
3 3
5 5
8 8
9 9
10 10
11 11
12 12
13 13
14 14
16 16
17 17
21 21
24 24
A
A
B
B
C
C D E
G
G
H J K L M
M
N
P Q
R S TF
23.9
S.1Q.1
19.5
SLAB05
SLAB06
61' - 8" ADDITION 84' - 0" EXISTING BUILDING 26' - 4 1/2" ADDITION
E X
IS
T
IN
G
B U
IL
D
IN
G
A D
D
IT
IO
N
A D
D
IT
IO
N
23' - 8" ADDITION 160' - 0" EXISTING BUILDING
28' - 0" 34' - 11 1/2" 4' - 0 1/2" 26' - 0" 4' - 1" 34' - 11" 28' - 0"
29' - 0" 26' - 0" 29' - 0"
/8
CJ
CJ
CJ
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
CJ
CJ
SLAB05
C J
C J
CJ
CJ CJ
CJ
S-511
4' - 6" 3' - 6" 4' - 6"
.2
.2
3' - 0" 3' - 9"
3.202
5' - 0"
8' - 0"
4' - 0"
A L
IG
N W
IT
H
C O
N T
R O
L J
O
IN
T S
O N
C
IV
IL
C O
N T
R O
L J
O
IN
T S
A T
S P
A C
IN
G
3.201
3.201
3.201
3.203
E X
T S
L
T S
L
T S
L
T S
L
T S
L
TSL
98' - 10"
S-511
4' - 6" 4' - 6" 7' - 6" 5' - 6"
R82'-6" R78'-0" R73'-6" R66'-0"
/8
/8
/4
/8
/8
/8
/8
3" 61' - 4" 1"
7 5/8" 60' - 0 3/4" 7 5/8"
10' - 0 3/4" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
/2
/2
/2
/4
/4
12' - 9 1/2" 12' - 9 1/2" 9 1/2"
S L A
B
S L A
B
S L A
B
S L A
B
S L A
B
TSL
100' - 0"
3.002
3.002
3.003
3.003
3.003
3.003
3.003
3.003
3.003
3.003
3.003
3.003
3.003
3.003
3.003
3.003
3.003
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CCJ
CJ
CJ
C J
C J
C J
C J
C J
C J
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ
CJ CJ CJ CJ
CJ
S-501
S-501
3.204
3.204
3.204
10' - 4"
2' - 3" 3' - 8" 7' - 0"
.2
2' - 3" 3' - 0"
3.003
5' - 0"
5' - 0"
S-511
S-511
3.205
3.205
3.206
3.206
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/3
/2
:0
:2
P M
C R e v it L o c a l\
-1
.0
-S -C e n tr a l-m je
.r v t
W
IS
C O
N S
IN
A
IR
N
A T
IO
N
A L G
U A
R D
T R
U A
X F
IE
L D
A N
G B
M A
D
IS
O N
W
I
A D
A L B
S-111
FLATWORK PLAN
XGFG132020ANG NO.:
3141300-141489.01
MJE
DRM
May 4, 2017
ZJE
KEYED NOTES
3.002 REMOVE EXISTING SLAB AND REPLACE WITH NEW SLAB PER
DETAILS ON SHEET S-511.
3.003 REMOVE EXISTING SLAB FOR REMOVAL OF EXISTING PIPING
AND/OR INSTALLATION OF NEW PIPING. COORDINATE EXACT
EXTENTS/LOCATIONS WITH OTHER DISCIPLINES. REPLACE SLAB
PER DETAILS ON SHEET S-511.
3.201 NEW CONCRETE STOOP, SEE DETAILS 7/S-511 AND 8/S-511.
3.202 NEW EXTERIOR CONCRETE EQUIPMENT PAD, SEE DETAIL 11/S-511.
COORDINATE EXACT LOCATION AND SIZE WITH CONTRACTOR.
3.203 NEW CONCRETE STAIR, SEE DETAIL 13/S-511
3.204 NEW INTERIOR CONCRETE EQUIPMENT PAD, SEE DETAIL 12/S-511.
COORDINATE EXACT LOCATION AND SIZE WITH CONTRACTOR.
3.205 EXISTING TILE TO BE REMOVED, INFILL DEPRESSED AREA WITH
CONCRETE TOPPING TO MATCH SURROUNDING FLOOR ELEVATION.
3.206 REMOVE EXISTING SLAB AND REPLACE WITH SLAB TYPE 'SLAB05' AT
NEW SHOWER LOCATION. SLOPE NEW SLAB TO DRAIN.
COORDINATE WITH ARCHITECTURAL.
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"1
FLATWORK PLAN
2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE
ATTENTION OF THE ARCHITECT/ENGINEER FOR FINAL DECISION.
3. REFER TO SHEET S-001 FOR STRUCTURAL LEGENDS, ABBREVIATIONS,
AND SYMBOLOGY.
4. REFER TO SHEET S-001 FOR ROOF LOADING AND SPECIAL JOIST
LOADING REQUIREMENTS.
5. REFER TO SHEET S-541 FOR TYPICAL DETAILS NOT REFERENCED ON
THIS SHEET.
6. MINIMUM JOIST BEARING LENGTH REQUIREMENTS ARE AS FOLLOWS
UNLESS NOTED OR DETAILED OTHERWISE;
- AT MASONRY WALLS - "K" SERIES - MIN. 4"
- AT CONCRETE WALLS - "K" SERIES - MIN. 4"
- AT STEEL BEAMS - "K" SERIES - MIN. 2 1/2"
7. ALL ROOF OPENINGS SHALL FOLLOW REQUIREMENTS OF DETAIL
6/S-541. COORDINATE WITH OTHER DISCIPLINES FOR LOCATIONS
AND OPENING SIZES.
8. ALL NEW CMU WALLS SHALL BE STRUCTURAL WALL TYPE SW08
UNLESS NOTED OTHERWISE. SEE DETAIL 1/S-521.
ROOF FRAMING
PLAN GENERAL NOTES:
1 1
2 2
3 3
5 5
8 8
9 9
10 10
11 11
12 12
13 13
14 14
16 16
17 17
21 21
24 24
A
A
B C D
D E
G
G
H J K L M
M
N
P
Q
Q
R S T
T
F
E X
W
X
E X
W
X
E X
W
X
EX. 20H7
E X
W
X
E X
W
X
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. W16X26
( 110' - 10 1/2" )
E X
W
X
/2
E X
W
X
E X
W
X
E X
W
X
/2
E X
W
X
E X
W
X
E X
W
X
E X
W
X
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. W16X26
( 110' - 10 1/2" )
E X
W
X
EX. W16X26
( 110' - 10 1/2" )
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
EX. W16X26
( 110' - 10 1/2" )
E X
W
X
E X
W
X
E X
W
X
E X
G
E X
G
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
E X
W
X
/2
EX. W12X14
( 110' - 8" )
E X
W
X
/2
EX. W18X35
( 110' - 8" )
EX. L5X5X3/8
( 110' - 10 1/2" )
EX. L5X5X3/8
( 110' - 10 1/2" ) E
X W
X
/2
E X
W
X
/2
E X
H
E X
H
EX. L5X5X3/8
( 110' - 10 1/2" )
EX. L5X5X3/8
( 110' - 10 1/2" )
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
EX. W16X26
( 110' - 10 1/2" )
EX. W16X26
( 110' - 10 1/2" )
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
EX. 20H7
23.9
S.1Q.1
19.5
38' - 0" 27' - 5" 27' - 7" 27' - 5" 38' - 0"
1' - 2 1/2" 25' - 1"
/2
/2
K
K
K
K
K
K
K
K
K
K
K
K
W
X
W
X
W
X
W
X
2' - 6 1/2"
(5) SPACES AT 4'-0" = 20' - 0"
2' - 6 1/2"
W10X30
( 110' - 8" )
W10X30
( 110' - 8" )
W10X33
( 110' - 2" )
158' - 5"
28' - 0" 33' - 4" 35' - 9" 33' - 4" 28' - 0"
4' - 1" 6' - 7" 14' - 5" 6' - 1" 4' - 7"
6" 26' - 7" 6"
3.601
S-541 13
HSS6X6X1/4
(TYPICAL OF 6)
S-551
S-551
S-551
S-541
S-541
S-541
S-541
S-541
S-541
S-541
S-541
S-541
WALL
SUPPORT
WALL
SUPPORT
WALL
SUPPORT
L19
L
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/3
/2
:0
:5
P M
C R e v it L o c a l\
-1
.0
-S -C e n tr a l-m je
.r v t
W
IS
C O
N S
IN
A
IR
N
A T
IO
N
A L G
U A
R D
T R
U A
X F
IE
L D
A N
G B
M A
D
IS
O N
W
I
A D
A L B
S-151
LOW ROOF FRAMING
PLAN
XGFG132020ANG NO.:
3141300-141489.01
MJE
DRM
May 4, 2017
ZJE
KEYED NOTES
3.601 1.5" DEEP, 20 GAUGE TYPE B ROOF DECK. SEE DETAILS ON SHEET
S-541.
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"1
LOW ROOF FRAMING PLAN
2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE
ATTENTION OF THE ARCHITECT/ENGINEER FOR FINAL DECISION.
3. REFER TO SHEET S-001 FOR STRUCTURAL LEGENDS, ABBREVIATIONS,
AND SYMBOLOGY.
4. REFER TO SHEET S-001 FOR ROOF LOADING AND SPECIAL JOIST
LOADING REQUIREMENTS.
5. REFER TO SHEET S-541 FOR TYPICAL DETAILS NOT REFERENCED ON
THIS SHEET.
6. MINIMUM JOIST BEARING LENGTH REQUIREMENTS ARE AS FOLLOWS
UNLESS NOTED OR DETAILED OTHERWISE;
- AT MASONRY WALLS - "K" SERIES - MIN. 4"
- AT CONCRETE WALLS - "K" SERIES - MIN. 4"
- AT STEEL BEAMS - "K" SERIES - MIN. 2 1/2"
7. ALL ROOF OPENINGS SHALL FOLLOW REQUIREMENTS OF DETAIL
6/S-541. COORDINATE WITH OTHER DISCIPLINES FOR LOCATIONS
AND OPENING SIZES.
8. ALL NEW CMU WALLS SHALL BE STRUCTURAL WALL TYPE SW08
UNLESS NOTED OTHERWISE. SEE DETAIL 1/S-521.
ROOF FRAMING
PLAN GENERAL NOTES:
1 1
2 2
3 3
4 4
5 5
6 6
8 8
10 10
12 12
13 13
15 15
16 16
17 17
19 19
20 20
22 22
23 23
24 24
A C
D
G
G
H L M
M
N
N Q
R TF
EX. W21X44
( 114' - 10 1/2" )
EX. 16H6
EX. W14X22
( 114' - 10 1/2" )
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
EX. 16H6
EX. 16H6
EX. 16H6
EX. 16H6
EX. 16H6
EX. 16H6
EX. 16H6
EX. 16H6
EX. W21X44
( 114' - 10 1/2" )
EX. W16X26
( 114' - 10 1/2" )
E X
W
X
E X
W
X
E X
W
X
EX. W16X26
( 114' - 10 1/2" )
E X
G
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
E X
G E
X
G
E X
G E
X
G E
X
G
E X
W
X
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
EX. 22H9
E X
W
X
E X
W
X
E X
W
X
E X
W
X
EX. W16X26
( 114' - 10 1/2" )
23.9
S.1Q.1
19.5
61' - 4" 10 1/2" 27' - 5" 27' - 7" 27' - 5" 26' - 3 1/2"
CMU
7 5/8"
60' - 0 3/4" CMU
7 5/8"
10 1/2"
4' - 0 3/8" (13) SPACES AT 4'-0" = 52' - 0" 4' - 0 3/8"
24' - 2 1/2" 28' - 0" 33' - 4" 35' - 9" 33' - 4" 28' - 0"
4' - 1" 6" 26' - 7" 6" 4' - 1"
/2
/2
C M
U
/8
/4
C M
U
/8
K
K
K
K
K
K
K
K
K
K
K
K
K
K
C M
U
/8
/4
C M
U
/8
/8
C M
U
/8
51' - 4" 10' - 0"
CMU
7 5/8"
50' - 0 3/4" CMU
7 5/8"
2' - 0 3/8"
JB
115' - 4"
JB
116' - 0"
S-551
S-551
S-551
S-551
S-551
3.601
TOW
118' - 0"
TOW
118' - 0"
TOW
118' - 0"
TOW
118' - 0"
TOW
118' - 0"
TOW
118' - 0"
.6
3.603
3.603
3.6033.603
61' - 0"
8' - 8"
24.3
PSF
55.7
PSF
SNOW DRIFT LOADING DIAGRAM
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/3
/2
:0
:2
P M
C R e v it L o c a l\
-1
.0
-S -C e n tr a l-m je
.r v t
W
IS
C O
N S
IN
A
IR
N
A T
IO
N
A L G
U A
R D
T R
U A
X F
IE
L D
A N
G B
M A
D
IS
O N
W
I
A D
A L B
S-152
INTERMEDIATE
ROOF FRAMING
PLAN
XGFG132020ANG NO.:
3141300-141489.01
MJE
DRM
May 4, 2017
ZJE
KEYED NOTES
3.601 1.5" DEEP, 20 GAUGE TYPE B ROOF DECK. SEE DETAILS ON SHEET
S-541.
3.602 SNOW DRIFT LOAD, SEE SNOW DRIFT LOADING DIAGRAM ON THIS
SHEET.
3.603 NEW FRAMED OPENING IN EXISTING ROOF, SEE DETAIL 6/S-551.
COORDINATE EXACT OPENING LOCATION WITH MECHANICAL.
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"1
INTERMEDIATE ROOF FRAMING PLAN
T.O. FOOTING
SEE FOUNDATION PLAN
12" FOUNDATION WALL
WITH #5 BARS AT 18" O.C.
EACH WAY, EACH FACE
#5 DOWELS, MATCH WALL
REINFORCING SPACING
2'-0"W X 1'-0"D FOOTING
WITH (2) #5 BARS CONTINUOUS
T.O. WALL/SLAB
100' - 0"
T.O. LEDGE
99' - 4"
6" 1' - 0" 6"
DOWELS TO MATCH
CMU WALL VERTICAL
REINFORCEMENT SIZE
AND SPACING, TYPICAL.
CMU WALL ABOVE
1 1/2" LEDGE
JOINT FILLER
REINFORCING CONTINUOUS
THROUGH JOINTS
CANT STRIP (EACH SIDE)
CLASS "B" LAP
NOTE:
SIMILAR AT WALLS WHERE
REINFORCEMENT IS PLACED
EACH FACE.
L CONSTRUCTION JOINTC
60'-0" MAX. SPACING 60'-0" MAX. SPACING
REINFORCING CONTINUOUS
THROUGH JOINTS
CANT STRIP (EACH SIDE)
NOTE:
SIMILAR AT WALLS WHERE
REINFORCEMENT IS PLACED
EACH FACE.
L CONTROL JOINTC
20'-0" MAX. SPACING 20'-0" MAX. SPACING
NOTE:
WHEN MASONRY IS ABOVE
ALIGN MASONRY AND
CONCRETE CONTROL
JOINTS.
"W
"W
"W
"W
"W" "W"
"W" "W"
REINFORCEMENT EACH FACE
REINFORCEMENT CENTERED
TYPICAL
2' - 0" BAR LAP
TYPICAL
2' - 0" BAR LAP
T Y
P
IC
A L
B A
R L
A P
T Y
P
IC
A L
B A
R L
A P
TYPICAL
2' - 0" BAR LAP
TYPICAL
2' - 0" BAR LAP
NOTES:
1.VERTICAL REINFORCING NOT SHOWN FOR CLARITY.
2.FOUNDATION WALL LEDGE NOT SHOWN FOR CLARITY.
3. "W" = FOUNDATION WALL WIDTH.
HORIZONTAL WALL
REINFORCING
OPTIONAL WALL
CONSTRUCTION JOINT
CORNER BARS TO MATCH
WALL REINFORCING
HORIZONTAL WALL
REINFORCING
OPTIONAL WALL
CONSTRUCTION JOINT
CORNER BARS TO MATCH
WALL REINFORCING
(2) #5 BARS EACH FACE,
TYPICAL
TYPICAL RECTANGULAR OPENING
IN CAST IN PLACE CONCRETE
TYPICAL CIRCULAR OPENING IN
CAST IN PLACE CONCRETE
A
B
(2) #5 BARS x 4'-0" LONG
EACH FACE, TYPICAL
NOTES:
1. APPLIES TO ALL
OPENINGS WHERE 'A' OR
'B' IS GREATER THAN OR
EQUAL TO CAST IN PLACE
CONCRETE THICKNESS.
2. VERIFY SIZE AND
LOCATION OF OPENINGS
WITH TRADE OR SUB-
CONTRACTOR
REQUIRING
OPENINGS.
(2) #5 BARS EACH FACE,
TYPICAL
(2) #5 BARS x 4'-0" LONG
EACH FACE, TYPICAL
NOTES:
1. APPLIES TO ALL HOLES
WHERE DIAMETER IS
GREATER THAN OR
EQUAL TO CAST IN PLACE
CONCRETE THICKNESS.
2. VERIFY SIZE AND
LOCATION OF OPENINGS
WITH TRADE OR SUB-
CONTRACTOR
REQUIRING
OPENINGS.
3. 2'-0" MAXIMUM OPENING
UNLESS NOTED
OTHERWISE.
M A
X
NOTES:
1. VERIFY OPENING AND
LOCATION OF OPENING
AND PIPE SLEEVE WITH
TRADE OR SUB-
CONTRACTOR.
2. SEE FOUNDATION PLANS
FOR VERTICAL AND
HORIZONTAL WALL
REINFORCING.
CAST IRON PIPE SLEEVE
3" T
YP
IC
AL
DIAGONAL BARS:
(4) #5 BARS, EACH FACE
2' - 0" M
IN
REINFORCING CONTINUOUS
THROUGH JOINTS, TYPICAL
CLASS "B" LAP
L CONSTRUCTION JOINTC
60' - 0" MAXIMUM SPACING 60' - 0" MAXIMUM SPACING
CLASS "B" LAP CLASS "B" LAP
C L A
S S
B
L
A P
BENT BAR AT CORNERS
SHALL MATCH FOOTING
REINFORCING
CONTINUOUS STRIP
FOOTING REINFORCING
(SEE SCHEDULE).
PROVIDE STANDARD
HOOK AT BAR ENDS
AS SHOWN.
T.O. FOOTING
SEE FOUNDATION PLAN
12" FOUNDATION WALL
WITH #5 BARS AT 18" O.C.
EACH WAY, EACH FACE
#5 DOWELS, MATCH WALL
REINFORCING SPACING
2'-0"W X 1'-0"D FOOTING
WITH (2) #5 BARS CONTINUOUS
T.O. WALL/SLAB
100' - 0"
T.O. LEDGE
99' - 4"
6" 1' - 0" 6"
METAL STUD WALL ABOVE
(SEE ARCHITECTURAL)
2 1/2" LEDGE
1 1/2" 10 1/2"
JOINT FILLER
T.O. EXISTING FOOTING
SEE FOUNDATION PLAN
EXISTING FOUNDATION
WALL
T.O. EXISTING WALL
100' - 0"
T.O. NEW FOOTING
99' - 4"
DOWELS TO MATCH
CMU WALL VERTICAL
REINFORCEMENT SIZE
AND SPACING, TYPICAL.
NEW CMU WALL ABOVE
NEW 2'-0" WIDE X 1'-0" DEEP
FOOTING WITH (2) #5 BARS
CONTINUOUS
JOINT FILLER
8"
2 1/2"
9 1/2"
S.1
23.9
T.O. PIER
99' - 4"
BASE PLATE BP-1
(SEE DETAIL 11/S-541) WITH
(4) 1/2" DIA. ANCHOR BOLTS
T.O. LEDGE
99' - 4"
/2
/2
/2
10 1/2"
1' - 1" 4"
T.O. WALL
100' -…