07_Mechanical.pdf

PDF 3 MB Posted

Attached to
XGFG132020 Add/Alter Building 404 Truax ANGB Madison WI
Solicitation number
W912J2-18-R-1001
Issued by

About this file

07 Mechanical

View the file

Other files

File Type Posted
281300.pdf PDF
095113.pdf PDF
062023.pdf PDF
A07-404_Q&A_IV_03_Feb_2018.pdf PDF
A07-W912J2-18-R-1001-0004_Amendment_ADAL_B404_03_Feb_18.pdf PDF
283176.pdf PDF
312000.pdf PDF
061053.pdf PDF
093000.pdf PDF
237450.pdf PDF
A07-404_Q&A_III_02_Feb_2018.pdf PDF
W912J2-18-R-1001-0003.pdf PDF
237433.pdf PDF
A07-404_Q&A_II_24_Jan_2018.docx DOCX document
A07-EXHIBIT_C_Reference_Questionnaire_Package_18Jan18_NEW.docx DOCX document
A07-W912J2-18-R-1001-0002_Amendment_ADAL_B404_18_Dec_18.pdf PDF
A07-404_Q&A_I_18_Jan_2018.docx DOCX document
A07-W912J2-17-R-1001-1001_Conform_Copy_18_Jan_18.pdf PDF
EXHIBIT_A-Performance_Relevancy_Questionnaire_18_Jan_2018.doc DOC document
A07-W912J2-18-R-1001-0001_Amendment_ADAL_B404_18_Dec_18.pdf PDF
A07-Pre_Proposal_Site_Visit_Sign_In_Sheet_404.pdf PDF
A07-Pre_Proposal_Slides_404.ppt PPT presentation
00_General.pdf PDF
02_Landscaping.pdf PDF
05_Fire_Protection.pdf PDF
04_Architectural.pdf PDF
06_Plumbing.pdf PDF
03_Structural.pdf PDF
01_Civil.pdf PDF
09_Technology.pdf PDF
08_Electrical.pdf PDF
A01-XGFG132020_Specifications_Vol_1.pdf PDF
EXHIBIT_C_-_Reference_Questionnaire_Package_NEW.docx DOCX document
A07-W912J2-18-R-1001_ADAL_B404_26_Dec_17.pdf PDF
A01-XGFG132020_Specifications_Vol_2.pdf PDF
EXHIBIT_B-Subcontractor_Information_and_Consent.doc DOC document
EXHIBIT_A-Performance_Relevancy_Questionnaire.doc DOC document
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PG

PA

PITCH

AV

MV

S

FS

LS

PS

TS

CO

CO2

NO2

RS

SP

H

TS

T

T

PIPE TURNED TOWARD

PIPE TURNED AWAY

PIPE TURNED AWAY

FLEXIBLE CONNECTOR

UNION

FLANGES

REDUCER (CONCENTRIC)

REDUCER (ECCENTRIC)

PIPE CAP

FLUID FLOW DIRECTION

PIPE GUIDE

PIPE ANCHOR

PIPE PITCH DIRECTION

NEW CONNECTION TO EXISTING

EXISTING TO REMAIN

EXISTING TO BE REMOVED

NEW TO BE INSTALLED

AUTOMATIC CONTROL VALVE (2-WAY)

AUTOMATIC CONTROL VALVE (3-WAY)

BACKFLOW PREVENTION VALVE

THROTTLING VALVE

BALANCING VALVE

FLOW MEASUREMENT STATION

RELIEF VALVE

AIR VENT (AUTO)

AIR VENT (MANUAL)

VACUUM BREAKER

PRESSURE GAUGE

TEMPERATURE GAUGE

WATER HAMMER ARRESTOR

ISOLATION/SHUT-OFF/MANUAL VALVE

GLOBE VALVE

BUTTERFLY VALVE

GATE VALVE

GLOBE ANGLE VALVE

PLUG VALVE

PRESSURE REDUCING VALVE

PRESSURE REGULATING VALVE

SOLENOID VALVE ONE-WAY (ELECTRIC)

STRAINER

PIPE TURNED TOWARD

GAUGE CONNECTION

PIPE PLUG

BALL VALVE

FLOW SENSOR

LEVEL SENSOR

PRESSURE SENSOR

TEMPERATURE SENSOR

FILTER

CHECK VALVE

PIPING SYMBOLS

REFRIGERANT SUCTION

REFRIGERANT LIQUID

REFRIGERANT HOT GAS

NATURAL GAS

RS

RL

G

HG

HOT WATER SUPPLY

HOT WATER RETURN

CONDENSATE DRAIN

CHILLED WATER SUPPLY

CHILLED WATER RETURN

HWS

HWR

CD

CHWS

CHWR

MECHANICAL PIPING:

CHEMICAL FEEDCF

GLYCOL WATER SUPPLY

GLYCOL WATER RETURN

GWS

GWR

(FIRST FIGURE IS SIDE SHOWN)

TEMPERATURE SENSOR

RECTANGLE DUCT SIZE

SUPPLY DUCT TURNED TOWARD

FIRE DAMPER & ACCESS DOOR

VOLUME DAMPER

CARBON MONOXIDE (CO) SENSOR

STATIC PRESSURE SENSOR

HUMIDISTAT

NITROGEN DIOXIDE (NO2) SENSOR

SMOKE DETECTOR

DUCT (FLEXIBLE ROUND)

ROOM SENSOR

TRANSITION (SQUARE-TO-ROUND)

MOTOR OPERATED DAMPER

AIR OUTLET/INLET TYPE

ROUND DUCT (RIGID)

EXHAUST

PARALLEL BLADE DAMPER

OPPOSED BLADE DAMPER

BACKDRAFT DAMPER

FLEXIBLE CONNECTION

(CFM)

TURNING VANES

SUPPLY DUCT TURNED AWAY

S

AD

MOD

FD

BD

12x12

SUPPLY OR OUTDOOR AIR

AIRFLOW (DOOR GRILLE)

AIRFLOW (SUPPLY)

HVAC SYMBOLS:

RETURN

AIRFLOW (RETURN)

DG

A

CARBON DIOXIDE (CO2) SENSOR

THERMOSTAT

INSULATED BASE THERMOSTAT

3/4" DOOR CUTOFF

DCO

12ø

12/12ø OVAL DUCT

SWITCH

SCIF GENERAL NOTES:

1. THE VAULT AREA IS CONSIDERED A SENSITIVE COMPARTMENTED

INFORMATION FACILITY. ALL NEW CONSTRUCTION AND RENOVATION TO THE

AREA INCLUDING WALL CONSTRUCTION, FIRE PROTECTION/DETECTION,

MECHANICAL/HVAC, ELECTRICAL, AND TECHNOLOGY SYSTEMS MUST

COMPLY WITH THE REQUIREMENTS PROVIDED IN UNIFIED FACILITY CRITERIA

4-010-05 SENSITIVE COMPARTMENTED INFORMATION FACILITY PLANNING,

DESIGN, AND CONSTRUCTION WITH CHANGE 1, 1 OCTOBER 2013, AND

REFERENCED IC TECH SPEC FOR ICD/ICS 705 TECHNICAL SPECIFICATIONS

FOR CONSTRUCTION AND MANAGEMENT OF SENSITIVE COMPARTMENTED

INFORMATION FACILITIES, VERSION 1.2, DATED 23 APRIL 2012.

2. CONSTRUCTION, GENERAL: UFC 4-010-05 REQUIREMENTS HAVE BEEN

INCORPORATED INTO THE DESIGN DRAWINGS AND SPECIFICATIONS.

CHANGES TO THE SCOPE OF WORK PROVIDED IN THE CONTRACT

DOCUMENTS MAY INVALIDATE THE APPROVALS RECEIVED FOR THIS

CONSTRUCTION, AND COULD RESULT IN THE REMOVAL AND

RECONSTRUCTION OF FINISHED WORK. ANY PROPOSED DEVIATIONS FROM

THE CONTRACT DOCUMENTS MUST BE FULLY REVIEWED AND APPROVED BY

THE COR PRIOR TO IMPLEMENTATION.

3. ALL CONSTRUCTION MUST BE DONE IN SUCH A MANNER AS TO PROVIDE

VISUAL EVIDENCE OF UNAUTHORIZED PENETRATION. CONSTRUCTION MUST

BE COMPLETED IN A MANNER TO PROVIDE THE REQUIRED STC RATINGS FOR

SOUND CONTROL AT THE WALLS IDENTIFIED. THROUGH-WALL

PENETRATIONS OF PIPE, CONDUIT, AND DUCTWORK REQUIRE SPECIAL

CONSTRUCTION AND INSPECTION PROVISIONS WHICH HAVE BEEN

INCORPORATED INTO THE CONTRACT DOCUMENTS.

4. THE CONTRACTOR SHALL SUBMIT A LIST OF ALL MATERIALS USED IN THE

CONSTRUCTION OF THE VAULT AREA, INCLUDING DIMENSIONAL EXTENTS OF

THE USE AND LOCATION(S) WHERE USED IN THE VAULT. THIS LIST SHALL BE

KEPT UP TO DATE DURING THE COURSE OF CONSTRUCTION AND SUBMITTED

TO THE COR AS PART OF THE CLOSE-OUT REQUIREMENTS AT THE END OF

CONSTRUCTION.

5. PHOTOGRAPHY REQUIREMENTS: THE CONTRACTOR IS NOT ALLOWED TO

HAVE PHOTOGRAPHIC OR RECORDING DEVICES IN THE VAULT AREA. 115 FW

CCZ PERSONNEL WILL BE TAKING PICTURES OF ON-GOING CONSTRUCTION

IN ORDER TO DOCUMENT THAT ALL SECURITY MEASURES ARE BEING MET.

THE COR SHALL BE NOTIFIED AT LEAST ONE WORKING DAY PRIOR TO KEY

CONSTRUCTION MILESTONES. KEY CONSTRUCTION MILESTONES INCLUDE

BUT ARE NOT LIMITED TO: WALL CONSTRUCTION, INCLUDING EACH OF

MULTIPLE LAYERS OF GYPSUM BOARD, FINISHING OF PENETRATIONS,

NON-CONDUCTIVE BREAKS OF PENETRATIONS, AND SOUND BATT

INSULATION INSTALLATIONS.

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:0

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

M-001

MECHANICAL NOTES

& SYMBOLS

XGFG132020ANG NO.:

3141300-141489.01

RRW/SMG

SNW

May 4, 2017

BGD

IPC INTERNATIONAL PLUMBING CODE

INWC INCHES WATER COLUMN PRESSURE

INHG INCHES MERCURY PRESSURE

IN INCH

IE INVERT ELEVATION

ID INSIDE DIAMETER

IBNLT INCLUDING BUT NOT LIMITED TO

IAW IN ACCORDANCE WITH

HZ HERTZ

HX HEAT EXCHANGER

HP HORSEPOWER

HDB HYDROSTATIC DESIGN BASIS

HC HOSE CONNECTION

H HEIGHT

GS GALVANIZED STEEL

GR GROOVED

GPM GALLONS PER MINUTE

GC GENERAL CONTRACTOR

GBS GASKETED BELL AND SPIGOT

GAL GAUGE

GAL GALLON

FTWC FEET WATER COLUMN PRESSURE

FT FEET

FS FLOOR SINK

FPM FEET PER MINUTE

FLOW FLOW OR FLOWRATE

FD FIRE DAMPER

FCO FLOOR CLEANOUT

FC FAN COIL

F FAHRENHEIT

EWT ENTERING WATER TEMPERATURE

EWC ELECTRIC WATER COOLER

ETR EXISTING TO REMAIN

ET EXPANSION TANK

ESEW EMERGENCY SHOWER AND EYE/FACE WASH

ELEC ELECTRIC

EL ELEVATION

EG EXHAUST GRILLE

EG ETHYLENE GLYCOL

EFT ENTERING FLUID TEMPERATURE

EFF EFFICIENCY

EF EXHAUST FAN

EEW EMERGENCY EYE/FACE WASH

EC ELECTRICAL CONTRACTOR

EAT ENTERING AIR TEMPERATURE

EA EXHAUST AIR

E EXISTING

DWV DRAIN, WASTE, AND VENT

DWG DRAWING

DN DOWN

DISCH DISCHARGE

DIM DIMENSION

DIA DIAMETER

DFD DEPARTMENT OF DEFENSE

DEMO DEMOLISH

DCVA DOUBLE CHECK VALVE ASSEMBLY BPD

DCO DOOR CUT-OFF

DBA DECIBELS, BAND A

CU COPPER

CTW CLOSE TO WALL

CTCLM CLOSE TO COLUMN

CTCLG CLOSE TO CEILING

CRA CONCRETE REACTION ANCHOR

COR CONTRACTING OFFICER'S REPRESENTATIVE

COMP COMPRESSOR

CISPI CAST IRON SOIL PIPE INSTITUTE

CI CAST IRON

CFM CUBIC FEET PER MINUTE

BZ BRONZE

BW BUTTWELD

BTW BOOTWASH

BTU BRITISH THERMAL UNIT

BS BLACK (MILD) STEEL

BRZ BRONZE

BRS BRASS

BR BRAZE

BPVC ASME BOILER & PRESSURE VESSEL CODE

BPD BACKFLOW PREVENTION DEVICE

BO BID OPTION

BHF BUTT HEAT FUSION

AT AIR TERMINAL

ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS

ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING,

AND AIR CONDITIONING ENGINEERS

ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS

APPROX APPROXIMATELY

ANG AIR NATIONAL GUARD

AHU AIR HANDLING UNIT

AHJ AUTHORITY HAVING JURISDICTION

AFF ABOVE FINISHED FLOOR

AFC ACOUSTICAL FLEXIBLE CONNECTOR

ACFM ACTUAL CFM

ABBREVIATIONS

W WATTS OR WIDTH

VLV VALVE

VFD VARIABLE FREQUENCY DRIVE

V VOLTS

UV ULTRAVIOLET

UTR UP THRU ROOF

UNO UNLESS NOTED OTHERWISE

UGD UNDERGROUND

UFC UNIFIED FACILITIES CRITERIA

TYP TYPICAL

TONR TONS COOLING

TH THREADED

TG TRANSFER GRILLE

TFB TO FLOOR BELOW

TFA TO FLOOR ABOVE

TEMP TEMPERATURE

TDS TOTAL DISSOLVED SOLIDS

TDH TOTAL DEVELOPED HEAD

SW SOCKET WELD

SV SOLVENT WELD

STL STEEL

STD STANDARD

SS STAINLESS STEEL

SRV SAFETY RELIEF VALVE

SQ SQUARE

SPEC SPECIFICATIONS

SP STATIC PRESSURE

SMLS SEAMLESS

SHT SHEET

SD SOLDER

SCH SCHEDULE

SCFM STANDARD CFM

RTD RESISTIVE THERMAL DEVICE

SG SUPPLY GRILLE

SA SUPPLY AIR

RTU ROOF TOP UNIT

RPM REVOLUTIONS PER MINUTE

RA RETURN AIR

QTY QUANTITY

PVC POLYVINYL CHLORIDE

PSIG PSI GAGE

PSID PSI DIFFERENTIAL

PSIA PSI ABSOLUTE

PSI POUNDS PER SQUARE INCH

PROP PROPELLER

PREDV PRESSURE REDUCING VALVE

PPH POUND PER HOUR

PL PLACES

PH PHASE

PG PROPYLENE GLYCOL

PD PRESSURE DROP/DIFFERENTIAL

PC PLUMBING CONTRACTOR

P PRESSURE

OFOI OWNER FURNISHED, OWNER INSTALLED

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

OED OPEN-ENDED DUCT

OD OUTSIDE DIAMETER

NPSHR NPSH REQUIRED

NPSHA NPSH AVAILABLE

NPSH NET POSITIVE SUCTION HEAD

NOM NOMINAL

NO NORMALLY OPEN

NIC NOT IN CONTRACT

NH NO-HUB

NG NATURAL GAS

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NEMA NATIONAL ELECTRICAL MANUFACTURER'S...

NC NORMALLY CLOSED

NA NOT APPLICABLE

MTL MATERIAL

MSS MANUFACTURERS STANDARDIZATION SOCIETY

MOD MODULATING

MOCP MINIMUM OVER CURRENT PROTECTION

MMBH MILLION BTU PER HOUR

MIN MINIMUM

MFR MANUFACTURER

MCC MOTOR CONTROL CENTER

MCA MINIMUM CIRCUIT AMPACITY

MC MECHANICAL COUPLING

MBH THOUSAND BTU PER HOUR

MAX MAXIMUM

MAWP MAXIMUM ALLOWABLE WORKING PRESSURE

MADP MAXIMUM ALLOWABLE DIFFERENTIAL PRESSURE

LWT LEAVING WATER TEMPERATURE

LPM LITERS PER MINUTE

LPG LIQUIFIED PETROLEUM GAS

LIN LINEAR

LCO LINE CLEANOUT

LB POUNDS

LAT LEAVING AIR TEMPERATURE

ABBREVIATIONS

9. SEQUENCE OF WORK AND/OR PLACE OF COMMENCEMENT OF WORK SHALL BE APPROVED PRIOR TO WORK BEING STARTED. SCHEDULED SHUTDOWNS SHALL BE CLOSELY COORDINATED WITH EXISTING OPERATIONS.

8. VERIFY ALL EQUIPMENT LOCATIONS AND PIPE ROUTING WITH OWNER PRIOR TO INSTALLATION.

7. TEMPORARILY PATCH ALL ROOF OPENINGS WATERTIGHT UNTIL FINAL CLOSURE CAN BE MADE.

6. ALL NEW AND EXISTING ROOFING SYSTEMS SHALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION

ACTIVITIES.

5. ACCURATE AND LEGIBLE AS-BUILT DRAWING MARKUPS SHALL BE MAINTAINED AT THE JOB SITE, AND BE

SUBMITTED PRIOR TO FINAL PAYMENT FOR THE CREATION OF FINAL RECORD DRAWINGS.

4. ANY AND ALL INFORMATION SHOWN ON THESE DRAWINGS WITH RESPECT TO EXISTING STRUCTURES, UTILITIES, AND MECHANICAL SYSTEMS, IS AS EXACT AS COULD BE SECURED. THE INFORMATION IS NOT WARRANTED NOR GUARANTEED ACCURATE, FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO PROCEEDING WITH WORK.

3. ELEVATION OF PIPING AND DUCTWORK INDICATED ON THESE DRAWINGS ARE TO BE USED AS GUIDELINES TO ASSIST WITH INSTALLATIONS. MINOR CHANGES TO THESE ELEVATIONS MAY BE NECESSARY TO ELIMINATE UNFORESEEN INTERFERENCES. ANY CHANGE IN ELEVATION SHALL BE APPROVED PRIOR TO CHANGE.

2. THESE DRAWINGS ARE DESIGN DRAWINGS AND ARE DIAGRAMMATIC, THEY MAY NOT SHOW ALL PHYSICAL ARRANGEMENTS, OFFSETS, BENDS, OR ELBOWS WHICH MAY BE REQUIRED FOR PROPER INSTALLATION OF VARIOUS MATERIALS, EQUIPMENT, PIPING AND DUCTWORK SYSTEMS IN ALLOTTED SPACES. EXAMINE THESE AND OTHER AVAILABLE DRAWINGS TO DETERMINE SPACE LIMITATIONS AND INTERFERENCES. MAKE ANY MINOR CHANGES IN LOCATIONS OF EQUIPMENT, PIPING, AND DUCTWORK FROM THAT SHOWN ON DRAWINGS AND FOR ALL PHYSICAL DETAILS REQUIRED FOR INSTALLATION. COST FOR ADAPTING WORK TO JOB SITE CONDITIONS

SHALL NOT BE CONSIDERED AS BASIS OF AN EXTRA COST TO CONTRACT.

1. ABBREVIATIONS INDICATED HERE AND NOT USED IN THE CONTRACT DOCUMENTS DO NOT APPLY TO THIS

PROJECT. ADDITIONAL ABBREVIATIONS MAY BE INDICATED IN THE CONTRACT DOCUMENTS.

GENERAL NOTES:

05/04/17 TYPE B3

REF.

REF. REF.

REF.

REF.

A B C D E GH J K LM N P Q R S TF Q.1 S.1

19.5

24.1

A B C D E F GH J K LM N P Q R S T

46x18(E) ø (E ø

(E

12x8(E)

AT(E)

AT(E)

AT(E)

AT(E)AT(E)

x1

(E x6 (E x1

(E ø (E x2

(E

48x24(E)

40x16(E)

AT(E)

AT(E)

24x18(E)

12x10(E)

18x10(E) x8 (E x8 (E x6 (E

12x6(E) x1

(E

14x10(E)

AT(E)

AT(E)

40x18(E) 48x24(E)

24x14(E) x2

(E

) AT(E)

AT(E)

AT(E)

AT(E)

AT(E)

AT(E)

x1

(E x1

(E

AT(E)

AT(E)

18x14(E)

14ø(E)

AT(E)

AT(E)

12x8(E)

10x8(E) x1

(E

30x20(E)

AT(E)

AT(E)

FCU(E)

FCU(E)

x1

(E

AT(E)

AT(E)

AT(E)

AT(E)

AT(E)

ø (E

AT(E)

AT(E)

AT(E)

24x10ø(E)

AT(E)

AT(E)

12x10(E)

12x10(E)

10x6(E)

8ø(E) 16ø(E)

60x20(E)

AT(E) 42x10(E)

AT(E)

AT(E)

48x8(E)

48x8(E)

EF(E)

x1

(E x6 (E x6

(E

8x6(E)

12x10(E)

CH(E)

x4 (E x4

(E

24x8(E) ø (E ø (E ø

(E

24x8(E) ø

(E ø

(E

8ø(E) ø

(E x1

(E

12x12(E)

24x6(E) ø

(E ø

(E ø

(E ø

(E

10ø(E)8ø(E)

10ø(E)8ø(E)

8ø(E) ø

(E

8x8(E)

10x6(E)

22x10(E)

6x6(E) ø

(E x1

(E

7ø(E)

22x10(E)

12x8(E)

20x14(E)

AT(E)

36x16(E)

AT(E)

5ø(E) 8x8(E)

8x4(E) 8x4(E) ø (E

22x22(E)AT(E)

6ø(E)

AT(E)

AT(E)

6ø(E)

AT(E)

10x6(E)

12x8(E)

12x12(E) x6 (E

10ø(E) 10ø(E)

22x22(E)

12x10(E) ø (E x8 (E

14x6(E)

10x8(E)

6ø(E)

10x10(E)

22x10(E)

LD(E)

LD(E)

LD(E)LD(E)LD(E)LD(E)

LD(E)

LD(E)

LD(E) LD(E) LD(E)

LD(E)

LD(E)

AT(E)

7.001

7.001

7.001

7.001

7.001

7.001

7.001

7.001

7.001

7.003 7.003

7.003

7.003

7.003

7.003

7.003 7.003

7.003

7.003

7.003

7.003

7.003

7.003

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP) (TYP)

(TYP)

(TYP)

(TYP)

(TYP)

7.002

7.004

7.004

7.004

7.004

7.004

7.004

7.004

7.004

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

7.005 7.005

36ø(E)

ELECTRIC CEILING

HEATING UNIT SERVING

THIS VESTIBULE TO REMAIN

P-4(E)

P-3(E)

UH(E)

CHILLER(E)

P-1(E)

ET-1(E)

GLYCOL

MIXING

TANK(E)

P-5(E)

AS-1(E)

7.005

7.005

7.005 ACCU(E)

C(E)

XFMER(E)

GENERATOR(E)

7.003

DEMOLISH DRYER VENT

EXHAUST

FAN(E)

14x6(E)14x6(E)

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:3

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

MD101

HVAC DEMOLITION

FLOOR PLAN

XGFG132020ANG NO.:

3141300-141489.01

RJH

SNW

May 4, 2017

BGD

PLAN

NORTH

TRUE

NORTH

1/8" = 1'-0"1

HVAC DEMOLITION FLOOR PLAN

KEYED NOTES

7.001 DEMOLISH ALL EXISTING AIR TERMINAL BOXES AND ALL ASSOCIATED

THERMOSTATS, ROOM SENSORS, VALVING AND SUPPORT HARDWARE.

UNLESS OTHERWISE INDICATED, DELIVER AIR TERMINAL BOXES,

THERMOSTATS, AND ROOM SENSORS TO BASE COMMANDER DESIGNATED

STORAGE SITE IN REUSABLE CONDITION. VERIFY BASE REQUIREMENTS

FOR EQUIPMENT RETENTION PRIOR TO BEGINNING DEMOLITION.

7.002 DEMOLISH ALL EXISTING FAN COIL UNITS AND ASSOCIATED DUCTS, PIPING,

CONTROLS, AND SUPPORT HARDWARE. UNLESS OTHERWISE INDICATED,

DELIVER UNITS TO BASE COMMANDER DESIGNATED STORAGE SITE IN

REUSABLE CONDITION. VERIFY BASE REQUIREMENTS FOR EQUIPMENT

RETENTION PRIOR TO BEGINNING DEMOLITION.

7.003 DEMOLISH ALL SUPPLY, EXHAUST, AND TRANSFER GRILLES, REGISTERS

AND LOUVERS AND ASSOCIATED SUPPORT AND MOUNTING HARDWARE.

7.004 DEMOLISH ALL SUPPLY, EXHAUST, AND TRANSFER DUCTWORK AND

ASSOCIATED SUPPORT AND MOUNTING HARDWARE.

7.005 DEMOLISH ALL DUCTWORK UP THROUGH ROOF INCLUDING ALL

ASSOCIATED ROOF MOUNTED HVAC EQUIPMENT AND PERMANENTLY

ENCLOSE ANY ROOF OPENINGS. REFER TO ARCHITECTURAL PLANS &

DETAILS. DELIVER EXHAUST FANS TO BASE COMMANDER DESIGNATED

STORAGE SITE IN REUSABLE CONDITION. VERIFY BASE REQUIREMENTS

FOR EQUIPMENT RETENTION PRIOR TO BEGINNING DEMOLITION

6. INSTALL TEMPORARY COVER OVER OPENING CREATED BY REMOVED

EQUIPMENT/PIPING. COVER SHALL BE WATERTIGHT, AND MEET OSHA AND

OWNER REQUIREMENTS. COMPLETELY REMOVE TEMPORARY COVER WHEN

OPENING BEING PATCHED TO FINAL CONDITION. REPAIR ANY DAMAGE TO

EXISTING BUILDING COMPONENTS CAUSED BY TEMPORARY COVER.

5. REINSTALL REMOVED EQUIPMENT, SAME AS NEW WORK, IN NEW LOCATION

INDICATED. COMPLETELY CLEAN AND RESTORE EQUIPMENT TO GOOD

OPERATING CONDITION PER SATISFACTION OF OWNER.

4. DELIVER REMOVED EQUIPMENT TO OWNER'S DESIGNATED STORAGE SPACE ON

SITE, PLUG OR CAP ALL EQUIPMENT OPENINGS TO PREVENT DIRT AND

MOISTURE FROM ENTERING EQUIPMENT PER SATISFACTION OF OWNER.

3. COMPLETELY REMOVE EXISTING DUCTWORK, INCLUDING ALL UNNEEDED

ACCESSORIES, INSULATION, HANGER SUPPORTS, ETC. FOR REMAINING DUCT

SYSTEM PLUG OR CAP ALL OPENINGS CREATED BY DUCT DEMOLITION. TEST

DUCTWORK AS SPECIFIED, AND INSULATE OR PAINT SAME AS NEW WORK. PATCH

EXISTING WALLS, ROOFS, CEILINGS, AND FLOORS DISTURBED BY DEMOLITION

TO ORIGINAL CONDITION PER SATISFACTION OF OWNER. DUCT DEMOLITION

SHALL INCLUDE ALL BOLDLY DISPLAYED DUCT INDICATED ON DRAWINGS.

2. COMPLETELY REMOVE EXISTING EQUIPMENT, INCLUDING ALL UNNEEDED PIPING,

VALVES, INSULATION, HANGERS, SUPPORTS, BASES, CONTROLS, ETC. PATCH

EXISTING WALLS, ROOFS, CEILINGS, AND FLOORS DISTURBED BY DEMOLITION

TO ORIGINAL CONDITION PER SATISFACTION OF OWNER.

1. COMPLETELY REMOVE INDICATED EXISTING PIPING, INCLUDING ALL UNNEEDED

PIPING, VALVES, INSULATION, HANGERS, SUPPORTS, ETC. FOR REMAINING

PIPING SYSTEMS PLUG OR CAP ALL OPENINGS CREATED BY PIPING DEMOLITION.

TEST PIPING SYSTEMS AS SPECIFIED, AND INSULATE OR PAINT SAME AS NEW

WORK. PATCH EXISTING WALLS, ROOFS, CEILINGS, AND FLOORS DISTURBED BY

DEMOLITION TO ORIGINAL CONDITION PER SATISFACTION OF OWNER. PIPING

DEMOLITION SHALL INCLUDE ALL BOLDLY DISPLAYED PIPES INDICATED ON

DRAWINGS.

GENERAL HVAC DEMOLITION NOTES:

A B C D E F GH J K LM N P Q R S T

ACCU(E)

RELIEF

HOOD(E)

RELIEF

HOOD(E)

ACCU(E)

ACCU(E)

ACCU(E)

ROOF

EXHAUSTER(E)

ROOF

EXHAUSTER(E)

RTU(E)

7.006

7.006

7.006

7.006

7.005

7.005

7.005

7.005

7.007

7.007

7.008 7.008

7.009

GOOSENECK

GOOSENECKGOOSENECK

7.005

RELIEF

HOOD(E)

7.005

7.005

7.005 7.005

BOILER STACK(E)

BOILER STACK(E)

WATER HEATER STACK(E)

7.005

DRYER VENT

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:3

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

MD102

HVAC DEMOLITION

ROOF PLAN

XGFG132020ANG NO.:

3141300-141489.01

RRW

SNW

May 4, 2017

BGD

PLAN

NORTH

TRUE

NORTH

1/8" = 1'-0"1

HVAC DEMOLITION ROOF PLAN

KEYED NOTES

7.005 DEMOLISH ALL DUCTWORK UP THROUGH ROOF INCLUDING ALL

ASSOCIATED ROOF MOUNTED HVAC EQUIPMENT AND PERMANENTLY

ENCLOSE ANY ROOF OPENINGS. REFER TO ARCHITECTURAL PLANS &

DETAILS. DELIVER EXHAUST FANS TO BASE COMMANDER DESIGNATED

STORAGE SITE IN REUSABLE CONDITION. VERIFY BASE REQUIREMENTS

FOR EQUIPMENT RETENTION PRIOR TO BEGINNING DEMOLITION

7.006 DEMOLISH REMOVE ACCU AND DELIVER TO BASE COMMANDER

DESIGNATED STORAGE SITE IN REUSABLE CONDITION UNLESS OTHERWISE

INSTRUCTED. VERIFY BASE REQUIREMENTS FOR EQUIPMENT RETENTION

PRIOR TO BEGINNING DEMOLITION.

7.007 DEMOLISH ROOF EXHAUSTER AND DELIVER TO BASE COMMANDER

DESIGNATED STORAGE SITE IN REUSABLE CONDITION UNLESS OTHERWISE

INSTRUCTED. VERIFY BASE REQUIREMENTS FOR EQUIPMENT RETENTION

PRIOR TO BEGINNING DEMOLITION.

7.008 REMOVE ALL ROOF MOUNTED DUCTWORK AND ASSOCIATED SUPPORTS

WITH NO DAMAGE TO ROOF.

7.009 DEMOLISH RTU AND PERMANENTLY ENCLOSE ANY ROOF OPENINGS. REFER

TO ARCHITECTURAL PLANS & DETAILS. DELIVER RTU TO COMMANDER

DESIGNATED STORAGE SITE IN REUSABLE CONDITION UNLESS OTHERWISE

INSTRUCTED. VERIFY BASE REQUIREMENTS FOR EQUIPMENT RETENTION

PRIOR TO BEGINNING DEMOLITION.

6. INSTALL TEMPORARY COVER OVER OPENING CREATED BY REMOVED

EQUIPMENT/PIPING. COVER SHALL BE WATERTIGHT, AND MEET OSHA AND

OWNER REQUIREMENTS. COMPLETELY REMOVE TEMPORARY COVER WHEN

OPENING BEING PATCHED TO FINAL CONDITION. REPAIR ANY DAMAGE TO

EXISTING BUILDING COMPONENTS CAUSED BY TEMPORARY COVER.

5. REINSTALL REMOVED EQUIPMENT, SAME AS NEW WORK, IN NEW LOCATION

INDICATED. COMPLETELY CLEAN AND RESTORE EQUIPMENT TO GOOD

OPERATING CONDITION PER SATISFACTION OF OWNER.

4. DELIVER REMOVED EQUIPMENT TO OWNER'S DESIGNATED STORAGE SPACE ON

SITE, PLUG OR CAP ALL EQUIPMENT OPENINGS TO PREVENT DIRT AND

MOISTURE FROM ENTERING EQUIPMENT PER SATISFACTION OF OWNER.

3. COMPLETELY REMOVE EXISTING DUCTWORK, INCLUDING ALL UNNEEDED

ACCESSORIES, INSULATION, HANGER SUPPORTS, ETC. FOR REMAINING DUCT

SYSTEM PLUG OR CAP ALL OPENINGS CREATED BY DUCT DEMOLITION. TEST

DUCTWORK AS SPECIFIED, AND INSULATE OR PAINT SAME AS NEW WORK. PATCH

EXISTING WALLS, ROOFS, CEILINGS, AND FLOORS DISTURBED BY DEMOLITION

TO ORIGINAL CONDITION PER SATISFACTION OF OWNER. DUCT DEMOLITION

SHALL INCLUDE ALL BOLDLY DISPLAYED DUCT INDICATED ON DRAWINGS.

2. COMPLETELY REMOVE EXISTING EQUIPMENT, INCLUDING ALL UNNEEDED PIPING,

VALVES, INSULATION, HANGERS, SUPPORTS, BASES, CONTROLS, ETC. PATCH

EXISTING WALLS, ROOFS, CEILINGS, AND FLOORS DISTURBED BY DEMOLITION

TO ORIGINAL CONDITION PER SATISFACTION OF OWNER.

1. COMPLETELY REMOVE INDICATED EXISTING PIPING, INCLUDING ALL UNNEEDED

PIPING, VALVES, INSULATION, HANGERS, SUPPORTS, ETC. FOR REMAINING

PIPING SYSTEMS PLUG OR CAP ALL OPENINGS CREATED BY PIPING DEMOLITION.

TEST PIPING SYSTEMS AS SPECIFIED, AND INSULATE OR PAINT SAME AS NEW

WORK. PATCH EXISTING WALLS, ROOFS, CEILINGS, AND FLOORS DISTURBED BY

DEMOLITION TO ORIGINAL CONDITION PER SATISFACTION OF OWNER. PIPING

DEMOLITION SHALL INCLUDE ALL BOLDLY DISPLAYED PIPES INDICATED ON

DRAWINGS.

REF.

REF. REF.

REF.

REF.

A B C D E GH J K LM N P Q R S TF Q.1 S.1

19.5

24.1

A B C D E F GH J K LM N P Q R S T

2"(E) 2"(E)

2 1/2"(E) 2 1/2"(E)

1 1/2"(E) 1 1/2"(E)

2 1/2"(E) 2 1/2"(E)

/2

E

/2

E

E

E

1"(E) 1"(E)

1 1/2"(E) 1 1/2"(E)

2 1/2"(E) 2 1/2"(E)

E

E

1 1/2"(E) 1 1/2"(E)

E

E

/4

E

/4

E

1"(E) 1"(E)

/4

E

/4

E

/4

E

) 3 /4

E

/4

E

/4

E

/2

E

/2

E

/4

E

/4

E

1 1/4"(E) 1 1/4"(E)

3/4"(E) 3/4"(E)

/4

E

/4

E

3/4"(E) 3/4"(E)

/4

E

/4

E

3/4"(E) 3/4"(E)

C(E) C(E)

AT(E)

AT(E)

C(E)

AT(E)

CH(E)

AT(E)

AT(E)

AT(E)

AT(E)

AT(E)

AT(E)

AT(E)

AT(E)

C(E)

AT(E)

AT(E)

AT(E)

AT(E)

C(E)

FT-1(E)

FT(E) FT-1(E)

AT(E)

FT(E)FT(E)

FT(E)

AT(E)

AT(E)

AT(E)

AT(E)

AT(E)

AT(E)

FCU(E)

AT(E)

AT(E)

AT(E)

AT(E)

AT(E)

C(E)

AT(E)

AT(E)

AT(E)

UH(E)

AS-1(E)

ET-1(E)

GLYCOL

MIXING

TANK(E)

P-1(E)

P-4(E)

P-3(E)

1/2"(E)

FT(E)

C(E)

CH(E)

FT(E)

FT(E)

FT(E) FT(E)

CH(E)

AT(E)

C(E)

C(E)

CHILLER(E)

8.001

8.007

8.002

8.001 8.001

8.002

8.002

8.002

8.003

8.003

8.002

8.002

8.002

FT(E) FT(E)

FT(E)

8.002

8.002

8.003

8.003

8.003 8.002

8.002

8.002

8.003

8.004

8.001

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

8.003

8.003

(TYP)

(TYP)

BOILER(E) BOILER(E)

ACCU(E)

NATURAL GAS

METER

(ETR)

8.001

8.0058.005

8.0058.005

E

8.006

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:4

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

MD131

MECHANICAL

DEMOLITION FLOOR

PLAN

XGFG132020ANG NO.:

3141300-141489.01

RRW

SNW

May 4, 2017

BGD

PLAN

NORTH

TRUE

NORTH

1/8" = 1'-0"1

MECHANICAL DEMOLITION FLOOR PLAN

KEYED NOTES

8.001 DEMOLISH EXISTING MECHANICAL EQUIPMENT AND ALL ASSOCIATED

VALVING AND SUPPORT HARDWARE. UNLESS OTHERWISE INDICATED,

DELIVER ALL EQUIPMENT TO BASE COMMANDER DESIGNATED STORAGE

SITE IN REUSABLE CONDITION. VERIFY BASE REQUIREMENTS FOR

EQUIPMENT RETENTION PRIOR TO BEGINNING DEMOLITION.

8.002 DEMOLISH ALL EXISTING HEATERS AND CONVECTORS AND ASSOCIATED

THERMOSTATS, PIPING, VALVING AND SUPPORT HARDWARE. UNLESS

OTHERWISE INDICATED, DELIVER HEATERS AND CONVECTORS TO BASE

COMMANDER DESIGNATED STORAGE SITE IN REUSABLE CONDITION.

VERIFY BASE REQUIREMENTS FOR EQUIPMENT RETENTION PRIOR TO

BEGINNING DEMOLITION.

8.003 DEMOLISH ALL HYDRONIC WATER SUPPLY AND RETURN PIPING, AND ALL

ASSOCIATED VALVING, HANGERS AND SUPPORT HARDWARE.

8.004 DEMOLISH ALL CHILLED WATER SUPPLY AND RETURN PIPING, AND ALL

ASSOCIATED VALVING, HANGERS AND SUPPORT HARDWARE.

8.005 EXISTING HYDRONIC PIPING TO REMAIN.

8.006 DEMOLISH EXISTING 1" NATURAL GAS PIPING BACK TO METER.

8.007 DEMOLISH UNDERGROUND CHILLED WATER PIPING. FILL IN TRENCH TO

MATCH SURROUNDING AREA.

6. INSTALL TEMPORARY COVER OVER OPENING CREATED BY REMOVED

EQUIPMENT/PIPING. COVER SHALL BE WATERTIGHT, AND MEET OSHA AND

OWNER REQUIREMENTS. COMPLETELY REMOVE TEMPORARY COVER WHEN

OPENING BEING PATCHED TO FINAL CONDITION. REPAIR ANY DAMAGE TO

EXISTING BUILDING COMPONENTS CAUSED BY TEMPORARY COVER.

5. REINSTALL REMOVED EQUIPMENT, SAME AS NEW WORK, IN NEW LOCATION

INDICATED. COMPLETELY CLEAN AND RESTORE EQUIPMENT TO GOOD

OPERATING CONDITION PER SATISFACTION OF OWNER.

4. DELIVER REMOVED EQUIPMENT TO OWNER'S DESIGNATED STORAGE SPACE ON

SITE, PLUG OR CAP ALL EQUIPMENT OPENINGS TO PREVENT DIRT AND

MOISTURE FROM ENTERING EQUIPMENT PER SATISFACTION OF OWNER.

3. COMPLETELY REMOVE EXISTING DUCTWORK, INCLUDING ALL UNNEEDED

ACCESSORIES, INSULATION, HANGER SUPPORTS, ETC. FOR REMAINING DUCT

SYSTEM PLUG OR CAP ALL OPENINGS CREATED BY DUCT DEMOLITION. TEST

DUCTWORK AS SPECIFIED, AND INSULATE OR PAINT SAME AS NEW WORK. PATCH

EXISTING WALLS, ROOFS, CEILINGS, AND FLOORS DISTURBED BY DEMOLITION

TO ORIGINAL CONDITION PER SATISFACTION OF OWNER. DUCT DEMOLITION

SHALL INCLUDE ALL BOLDLY DISPLAYED DUCT INDICATED ON DRAWINGS.

2. COMPLETELY REMOVE EXISTING EQUIPMENT, INCLUDING ALL UNNEEDED PIPING,

VALVES, INSULATION, HANGERS, SUPPORTS, BASES, CONTROLS, ETC. PATCH

EXISTING WALLS, ROOFS, CEILINGS, AND FLOORS DISTURBED BY DEMOLITION

TO ORIGINAL CONDITION PER SATISFACTION OF OWNER.

1. COMPLETELY REMOVE INDICATED EXISTING PIPING, INCLUDING ALL UNNEEDED

PIPING, VALVES, INSULATION, HANGERS, SUPPORTS, ETC. FOR REMAINING

PIPING SYSTEMS PLUG OR CAP ALL OPENINGS CREATED BY PIPING DEMOLITION.

TEST PIPING SYSTEMS AS SPECIFIED, AND INSULATE OR PAINT SAME AS NEW

WORK. PATCH EXISTING WALLS, ROOFS, CEILINGS, AND FLOORS DISTURBED BY

DEMOLITION TO ORIGINAL CONDITION PER SATISFACTION OF OWNER. PIPING

DEMOLITION SHALL INCLUDE ALL BOLDLY DISPLAYED PIPES INDICATED ON

DRAWINGS.

R E

F R

E F

F.E.

F.E.

F.E.

REF.

D W

R E

F

DW

REF.

A B C D E GH J K LM N P Q R S TF Q.1 S.1

19.5

24.1

A B C D E F GH J K LM N P Q R S T

VRF-E119

VRF-E122

VRF-E117

VRF-W107

VRF-W101

VRF-W100

VRF-W103

VRF-W116

VRF-W114

VRF-W113

VRF-W115

VRF-W112

VRF-W102

VRF-E120

VRF-W108 VRF-W105

VRF-W110

VRF-W109

VRF-W111

VRF-W106

VRF-E108

VRF-E107 VRF-E106 VRF-E104 VRF-E103

VRF-E102VRF-E101VRF-E109VRF-E110

VRF-E113

VRF-E112

VRF-E114

VRF-E115

VRF-E116

VRF-E123

VRF-E126

VRF-E124

VRF-E100

VRF-E105

VRF-E127

RG-1RG-1RG-1

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-1RG-1RG-1

RG-1RG-1RG-1

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-1RG-1RG-1

RG-2RG-2RG-2

RG-1RG-1RG-1

RG-2RG-2RG-2

RG-1RG-1RG-1

RG-1RG-1RG-1

CD-3CD-3CD-3

CD-3CD-3CD-3

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-3CD-3CD-3

CD-3CD-3CD-3

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-2CD-2CD-2225

CD-2CD-2CD-2

CD-2CD-2CD-2

ACCU-2

FC-1FC-2

CRAC-2 CRAC-1

ACCU-1A

ACCU-1B

CRAC-3

VRF-E125

MOD-1B

EG-1EG-1EG-1

L-1

L-2

8x88x8

UTR TO EF-1

THRU EXISTING

ROOF OPENING

RG-1RG-1RG-1

CD-4CD-4CD-4 175

CD-4CD-4CD-4

RG-1RG-1RG-1

SG-1SG-1SG-1

CD-1CD-1CD-1

CD-1CD-1CD-1

RG-1RG-1RG-1

RG-1RG-1RG-1

CD-1CD-1CD-1

SG-2SG-2SG-2

RG-2RG-2RG-2

SG-3SG-3SG-3

SG-3SG-3SG-3

SG-3SG-3SG-3

14ø SA DN

TO SIM

(900 CFM)

14ø SA DN

TO SIM

(900 CFM)

16x16 EA

UTR TO

AHU-2

18x24 OA

UTR TO

AHU-2

25x22 OA

UTR TO

AHU-1

32x13 EA

UTR TO

AHU-1

T

T T

T

T

TTT

T

T

T

T

T

T

T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T T

T

CRAC-4

T

T

T

T

T

TT

TT

T

T

T

T

T

T

T

T

T

T

T

RG-2RG-2RG-2

T

S

S

S

S 7.101

7.102

7.101

S

SIMULATOR

ELEC

CORR

ARMS

VEST

COPY

ROOM

HALLWAY

LOBBY

VEST

VEST

HALLWAY

7.103

RG-2RG-2RG-2

16x616x6

OED 335 CFM

CD-2CD-2CD-2

MOD-1A

EG-2EG-2EG-2

RG-2RG-2RG-2

12ø12ø12ø12ø

36x1236x12

6ø6ø

6x66x612x612x6

XFMER(E)

VRF-W117

VRF-E129

VRF-E128

SG-3SG-3SG-3

SG-3SG-3SG-3

SG-3SG-3SG-3

SG-3SG-3SG-3

SG-3SG-3SG-3

x1 x1 x1 x1

16x1616x16 ø ø x1 x1

8ø8ø

19x1019x10 x1 x1 x1 x1 x2 x2 x2 x2

14ø14ø 14ø14ø

6x86x8

6ø6ø

4ø4ø

4ø4ø x1 x1

8ø8ø ø ø x1 x1 x1 x1

12x812x8

4ø4ø 4ø4ø

4ø4ø

4ø4ø

4ø4ø 4ø4ø

10ø10ø ø ø

4ø4ø ø ø ø ø ø ø

30x1430x14

19x1019x1012x812x8

19x1019x10

12x812x8 x1 x1 x8 x8

VRF-E121

ø ø

12x612x6

VRF-E118

CD-2CD-2CD-2

CD-2CD-2CD-2

RG-1RG-1RG-1

CD-2CD-2CD-2

CD-2CD-2CD-2

CD-1CD-1CD-1

RG-2RG-2RG-2

RG-1RG-1RG-1

CD-2CD-2CD-2

CD-2CD-2CD-2

VRF-E111

19x1019x10

12x812x8

12x612x6

RG-2RG-2RG-2

RG-2RG-2RG-235

RG-2RG-2RG-2

x1 x1 x1 x1 x1 x1

6ø6ø ø ø ø ø ø ø ø ø ø ø ø ø

10x610x6

8x88x8

OED 250 CFM

x6 x6

10x1010x1019x1019x1012x812x8 ø ø

16x1216x12

10ø10ø ø ø ø ø x1 x1 x8 x8

19x1019x10

12x1212x12

10ø10ø x x x x x x

10x1010x10

19x1219x1212x1412x14

CD-1CD-1CD-1

8x68x6

12ø12ø

8x88x8

8x88x8

RG-2RG-2RG-2

ø ø ø ø ø ø ø ø x x

4ø4ø

4ø4ø ø ø

4ø4ø

VRF-W104

RG-1RG-1RG-1

RG-2RG-2RG-2

CD-2CD-2CD-2

CD-2CD-2CD-2

12x612x6

14ø14ø

14x1414x14 x1 x1

RG-1RG-1RG-1

CD-3CD-3CD-3

CCA

OSS

COMMANDER

OPERATIONS

GROUP

COMMANDER

FIGHTER

SQUADRON

COMMANDER

VEST

HALLWAY

DIRECTOR

OF

OPERATIONS

AIRFIELD

MANAGEMENT

AFMT

NCOIC

OPERATIONS

CHIEF

STAN

EVAL

CONFERENCE

ROOM

AFE

NCOIC

MEN'S

TOILET/

LOCKER

ROOM

AIRCREW

FLIGHT

EQUIPMENT

SOF

SIMULATOR

SUPPORT

OFFICE

125 SCHEDULING

STORAGE

FLIGHT

COMMANDERS

ARMS

NCOIC

SECURED

VEST

MX

DEBRIEF

COMM/

COMPUTER

STORAGE

WEAPONS

ACMI

CLASSROOM

INTEL

VAULT

INTEL

INTEL

NCOIC

INTEL OIC

BRIEFING

ROOM 3

BRIEFING

ROOM 1

BRIEFING

ROOM 2

BRIEFING

ROOM 4

LIBRARY

STORAGE

BREAK

ROOM

ISSO &

SSR

MISSION

PLANNING

OPEN

OFFICE

PM/PSM

SECURE

VAULT

MAIN

BRIEFING

ROOM

KITCHEN/

VENDING

BREAK

ROOM

STORAGE

AFE

INSPECTION

ROOM

COMM

ELEC

AFE

STORAGE

MECH

JANITOR

WOMEN'S

TOILET/

LOCKER

ROOM

AFE

SUPERINTENDENT,

FEO

NVG

TRAINING

OFFICER

HALLWAY

VEST

HALLWAY

WOMENS

ENTRY

STORAGE

166A

STORAGE

166B

STORAGE

166C

6ø6ø

CD-4CD-4CD-4

CD-4CD-4CD-4

36x1036x10

VRF-E130

18x1018x10 x8 x8

CD-4CD-4CD-4

CD-4CD-4CD-4

CD-4CD-4CD-4

CD-4CD-4CD-4

CD-4CD-4CD-4

CD-4CD-4CD-4

52x1652x16 x1 x1 x1 x1

10ø10ø

7.104

(2-WAY)50

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

RG-2RG-2RG-2

7.105

S

S

14x6(E)

14x6(E)

14x6(E) x1

(E

20x14(E)

CD-(E)CD-(E)CD-(E)CD-(E)

CD-(E)CD-(E)CD-(E)CD-(E)

CD-(E)CD-(E)CD-(E)CD-(E)

CD-(E)CD-(E)CD-(E)CD-(E)

14x1214x12

10ø10ø x8 x8

RG-3RG-3RG-3

SG-4SG-4SG-4

CUH(E)

7.106

UH-2

UH-3

10ø10ø

S

10x810x8

12x1212x12

10ø10ø

10ø10ø

CUH-3

CUH-2

C-1

C-4

C-3

CUH-6

UH-1

CUH-5

CUH-1

CUH-4

CUH-7

RG-2RG-2RG-2

RG-2RG-2RG-2

T x1 x1

12x812x8

52x1852x18

52x1052x10 ø ø

10ø10ø

7.104

H

HH

H

SG-1SG-1SG-1

MOD-2A

ø ø

7.107

MOD-2B 12x1212x12

OED W/ 1/2" X 1/2"

SCREEN UTR TO

EF-2

7.1087.108

7.108

7.108

7.108

UH-4

x1 x1

14x1014x10

16x1016x10

FIRE

ALARM

20x1420x14

12x1212x12

OED

OED

x1 x1 x8 x8

RG-2RG-2RG-2

ø ø

OED

DCO

DCO

DCO

DCO

DCO

DCO

DCO

19x1019x10

19x1019x10

6ø6ø 12x1012x10

DCO

DCO

TG-1TG-1TG-1

TG-1TG-1TG-1

x8 x8

OED

DCO

4ø4ø

TG-2TG-2TG-2

TG-2TG-2TG-2

16x816x8

12x1212x12 ø ø

7.108

7.1087.108

DCO

x1 x1 x1 x1 x1 x1

10x810x810x810x8

10x810x8

10x810x810x810x8

10x810x810x810x8

10x810x8 10x810x8

10x810x8

16x1016x10

16x1016x10

16x1016x10 16x1016x10

10x810x8

10x810x8

10x810x8

10x810x8

10x810x8

10x810x8

10x810x8

10x810x8

10x810x8

10x810x8

10x810x8

10x810x8

OED

x1 x1 x1 x1

16x1616x16 ø ø

4ø4ø

18x618x6

10x810x8

10x810x8

M-301

6ø6ø

AD

AD

BURGLAR

BARS

AFC

BURGLAR

BARS

AFC

RG-4RG-4RG-4

SG-5SG-5SG-5

x1 x1 414x1414x14

S

S

(IN RETURN PLENUM)

(IN RETURN PLENUM)

AD

AD

CUH-1

CUH-2

VRF-E100

T

7.109

T

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:1

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

M-101

HVAC FLOOR PLAN

XGFG132020ANG NO.:

3141300-141489.01

RRW/SMG

SNW

May 4, 2017

BGD

KEYED NOTES

7.101 MECHANICAL VENTILATION EMERGENCY KILL SWITCH.

7.102 BOILER SHUTDOWN BUTTON PER ASME CSD-1. LOCATE A MANUALLY

OPERATED REMOTE SHUTDOWN SWITCH OR CIRCUIT BREAKER LOCATED

JUST INSIDE THE BOILER ROOM EXTERIOR DOOR AND MARKED FOR EASY

IDENTIFICATION. THE SWITCH MUST SHUT DOWN ALL POWER TO THE

BURNER CONTROLS.

7.103 OA DUCT DOWN THRU VAULT CAP

7.104 PROVIDE BURGLAR BARS AT PENETRATION OF SECURE AREA ROOF.

PROVIDE FLEXIBLE CANVAS DUCT CONNECTOR ON SECURE SIDE OF ROOF

AND DUCT ACCESS DOOR FOR INSPECTION OF BURGLAR BAR INTEGRITY.

7.105 COORDINATE WITH SIMULATOR LAYOUT. ROUTE 14" Ø HARD DUCT TO

WITHIN 6 FEET OF FLOOR AND TERMINATE WITH A SECOND VOLUME

DAMPER ADJUSTABLE WHILE STANDING ON THE FLOOR AND 8 FEET OF

FLEXIBLE DUCT. FINAL CONNECTION TO SIMULATOR BY SIMULATOR

INSTALLER.

7.106 ELECTRIC CEILING MOUNTED CABINET UNIT HEATER (ETR)

7.107 4" Ø ALUMINUM DRYER VENT FROM EXISTING DRYER. TERMINATE WITH 4" Ø

WALL CAP.

7.108 EXHAUST DUCTWORK AND DAMPERS SERVING SHOWER AREAS TO BE

CONSTRUCTED OF ALUMINUM FROM THE SHOWER/LOCKER ROOM AREAS

BACK TO MAIN BRANCH TAPS AND MAIN BRANCH BACK TO MAIN DUCT RUN.

7.109 T-STAT FOR UH-4 TO BE SET FOR MINIMUM 5°F BELOW SETPOINT OF CRAC

UNITS.

PLAN

NORTH

TRUE

NORTH

1/8" = 1'-0"1

HVAC FLOOR PLAN

05/04/17 TYPE B3

11. PROVIDE MANUFACTURER'S RECOMMENDED CLEARANCES ON ALL EQUIPMENT.

10. VERIFY FINAL LOCATIONS OF ROOM THERMOSTATS / SENSORS / CONTROLS

WITH OWNER PRIOR TO INSTALLATION.

9. PROVIDE MINIMUM 5 FEET OF STRAIGHT DUCT ON OUTLET OF ALL VRF UNITS

PRIOR TO ANY TRANSITION, ELBOW, OR TAKE-OFF.

8. PROVIDE FLEXIBLE DUCTWORK FOR FINAL CONNECTIONS TO SUPPLY AIR

DIFFUSERS UNLESS NOTED OTHERWISE IN SPECIFICATIONS.

7. COORDINATE DIFFUSER, REGISTER, AND GRILLE LOCATIONS WITH REFLECTED

CEILING PLAN.

6. PROVIDE MANUAL BALANCING DAMPER AT EACH DIFFUSER/GRILLE BRANCH

TAKE-OFF IN ALL SUPPLY, RETURN, AND EXHAUST DUCTWORK. LOCATE

BALANCING DAMPER AS CLOSE TO BRANCH TAKE-OFF AS POSSIBLE.

5. DUCT RUN-OUTS TO EACH DIFFUSER TO BE THE SAME AS DIFFUSER NECK SIZE

UNLESS NOTED OTHERWISE.

4. CONTROL CONTRACTOR IS RESPONSIBLE FOR COORDINATING POWER FOR HIS

EQUIPMENT WITH ELECTRICAL CONTRACTOR AND INSURING ALL COSTS

ASSOCIATED WITH SUCH ARE INCLUDED IN THE PROJECT COST.

3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR EXACT LOCATIONS OF

ELECTRICAL PANELS AND EQUIPMENT. DO NOT RUN PIPING/DUCTWORK OVER

TOP OF OR WITHIN 3'-0" CLEAR HORIZONTALLY IN FRONT OF ALL ELECTRICAL

EQUIPMENT OR PANELS.

2. REFER TO SHEET M-001 FOR LEGENDS, ABBREVIATIONS, AND SYMBOLOGY.

1. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE ATTENTION

OF THE ARCHITECT/ENGINEER FOR FINAL DECISIONS.

GENERAL HVAC NOTES:

NOTE:

SEE DETAILS 13/M-501 AND 14/M-501 FOR SIZES AND SPECIAL

INFORMATION ON TRANSFER DUCTS ABOVE CELING.

A B C D E GH J K LM N Q R S T

AHU-1

EF-1

EF-2

G

1" G

ACCU-4

RL TFB

1" G DN

ACCU-3

RL TFB

RS TFB

RS TFB

ROOF HATCH

AHU-2

UTILIZE EXISTING

ROOF OPENING

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:1

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

M-102

HVAC ROOF PLAN

XGFG132020ANG NO.:

3141300-141489.01

RRW/SMG

SNW

May 4, 2017

BGD

PLAN

NORTH

TRUE

NORTH

1/8" = 1'-0"1

HVAC ROOF PLAN

R E

F .R

E F

F.E.

F.E.

F.E.

REF.

D W

R E

F

DW

REF.

A B C D E GH J K LM N P Q R S TF Q.1 S.1

19.5

24.1

A B C D E F GH J K LM N P Q R S T

FC-2 FC-1

ACCU-1A

ACCU-1B

CRAC-3

M-401

M-401

M-401

UH-1

CUH-4

CUH-2

CUH-3

CUH-1

C-1

1" HWS

1" HWR

2 1/2" HWRCRAC-4

T

3/4" CD

2 1/2" HWS

3/4"

3/4"

3/4"

1 1/4" HWS

CRAC-1CRAC-2

CUH-6

H W

S

/4

/4

CUH-5

CUH-7

3/4"

VRF-E113

VRF-E119

VRF-E108

VRF-E107 VRF-E106 VRF-E104 VRF-E103

VRF-E102VRF-E101VRF-E109

VRF-E110

VRF-E117

VRF-E122

VRF-W107

VRF-E120

VRF-E105

VRF-E112

VRF-E114

VRF-E116

VRF-E115

VRF-W102

VRF-W116

VRF-W115

VRF-W114 VRF-W113

VRF-W111

VRF-W112

VRF-W109

VRF-W110

VRF-W108

VRF-W105

VRF-W103

VRF-E124

VRF-E100

VRF-E127

VRF-E123

VRF-E126

VRF-E125

VRF-W101

VRF-W100

VRF-W117

VRF-W106

VRF-E128

ACCU-2

C-3

C-4

C-2

/4

/4

/4

/4

3/4"

/4

3/4" HWR

3/4"

1 1/4" HWS

1 1/4" HWR

NATURAL

GAS

METER

BSB-6

BSB-5

BSB-4

BSB-3

BSB-2

BSB-1

FT-1

2 FT 1.0 GPM

FT-1

14 FT 1.0 GPM

FT-1

3 FT 0.6 GPM

FT-1

10 FT 1.2 GPM

FT-1

8 FT 1.2 GPM

FT-1

6 FT 0.6 GPM

FT-1

8 FT 0.5 GPM

FT-1

8 FT 0.5 GPM

FT-1

10 FT 0.7 GPM

FT-1

6 FT 0.5 GPM

FT-1

8 FT 1.2 GPM

FT-1

10 FT 1.2 GPM

FT-1

10 FT 0.7 GPM

FT-1

6 FT 1.8 GPM

FT-1

16 FT 1.8 GPM

FT-1

6 FT 1.8 GPM

FT-1

6 FT 0.5 GPM

FT-1

6 FT 0.5 GPM

FT-1

10 FT 0.7 GPM

FT-1

10 FT 0.7 GPM

FT-1

6 FT 0.5 GPM

FT-1

8 FT 0.9 GPM

FT-1

6 FT 0.9 GPM

FT-1

8 FT 0.5 GPM

FT-1

6 FT 0.8 GPM

FT-1

6 FT 0.8 GPM

/2

H W

S

/2

H

W R

2" HWS

2" HWR

H W

S

H

W R

1 1/4" HWR

1 1/4" HWS

3/4"

3/4"

3/4"

/4

H G

R S

R L

H G

R S

R L

R L

R S

H G

RL

RS

HG

RL

RS

HG

H G

R S

R L

RL /RS

RL /RS

R L

RL /RS

RL /RS

RL /RS

R L R

S

R L R

S

RL /RS

RL /RS

R L R

S R

L R

S R

L R

S R

L R

S R

L R

S

RL /RS

R L R

S

R L R

S

R L R

S R

L R

S

3/4"

3/4"

3/4"

3/4"

3/4"

R L

R L R

S R

L R

S

RL /RS

RL /RS

RL /RS

R L R

S R

L R

S

RL /RS

RL /RS

RL /RS

RL /RS

RL /RS

RL /RS

RL /RS

RL /RS

RL /RS

RL /RS

RL /RS

RL /RS

R L R

S

R L R

S

RL /RS

VRF-E118

VRF-E111

VRF-E129

VRF-W104

VRF-E121

LCO

LCO

LCO

LCO

LCO

LCO

LCO

CD

CD

CD

C D

1 1/2" CD

C D

C D

CD

C D

C D

C D

C D

C D

1 1/2" CD

C D

CD

/2

C D

CD

CD

CD

CD

CD

CD

CD

C D

1 1/2" CD

CD

CD

CD

CD

CD

/2

C

DCD

CD

/2

C D

CD

CD

CD

CD

CDCD

CD

CD CD

CD

CD

/2

C D

CD

CD

/4

C

D

/2

C D

1 1/2" CD

DN TO HD

1 1/2" CD

DN TO HD

1 1/2" CD

DN TO HD

1 1/2" CD

1 1/4" HWS

1 1/4" HWR

GWS

GWR

1 1/4" HWR

GWS

GWR

LCO

CD

1 1/2" CD

DN TO HD

LCO

1" CD

C D

CD

LCO

CD

C D

C D C D

LCO

LCO

R L R

S R

L R

S R

L R

S R

L R

S

/2

C D

RL UTR

RS UTR

HG

RS

RL

CCA

OSS

COMMANDER

OPERATIONS

GROUP

COMMANDER

FIGHTER

SQUADRON

COMMANDER

VEST

HALLWAY

DIRECTOR

OF

OPERATIONS

AIRFIELD

MANAGEMENT

AFMT

NCOIC

OPERATIONS

CHIEF

STAN

EVAL

CONFERENCE

ROOM

AFE

NCOIC

MEN'S

TOILET/

LOCKER

ROOM

AIRCREW

FLIGHT

EQUIPMENT

SOF

SIMULATOR

SUPPORT

OFFICE

SCHEDULING

STORAGE

FLIGHT

COMMANDERS

ARMS

ARMS

NCOIC

SECURED

VEST

MX

DEBRIEF

COMM/

COMPUTER

STORAGE

WEAPONS

ACMI

CLASSROOM

INTEL

VAULT

INTEL

INTEL

NCOIC

INTEL OIC

BRIEFING

ROOM 3

BRIEFING

ROOM 1

BRIEFING

ROOM 2

BRIEFING

ROOM 4

LIBRARY

STORAGE

BREAK

ROOM

ISSO &

SSR

MISSION

PLANNING

OPEN

OFFICE

PM/PSM

SECURE

VAULT

VEST

LOBBY

MAIN

BRIEFING

ROOM

KITCHEN/

VENDING

BREAK

ROOM

VEST

169HALLWAY

STORAGE

AFE

INSPECTION

ROOM

COMM

ELEC

AFE

STORAGE

MECH

CORR

JANITOR

WOMEN'S

TOILET/

LOCKER

ROOM

AFE

SUPERINTENDENT,

FEO

NVG

COPY

ROOM

TRAINING

OFFICER

SIMULATOR

HALLWAY

VEST

HALLWAY

VEST

HALLWAY

WOMENS

ENTRY

STORAGE

166A

STORAGE

166B

STORAGE

166C

1" G UTR

8.102

8.102

8.103

8.1038.103

8.103

8.103

8.1038.103

8.103

8.1038.103

8.1038.103

1"1"

3/4"3/4"

8.1018.101

8.1018.101

8.1018.101

8.1018.101

8.1018.101

8.1018.101

1 1/2" CD

8.1018.101

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

8.103

(TYP)

ROUTE NEW PIPING TO

CUH-2 SIMILAR TO EXISTING

CUH(E)

7.106

8.101

UH-2

UH-3

P-7 P-6

M-401

M-401

1" 3/4"

3/4" 3/4"

3/4"

1"1" HWS

1" HWR

1"

/4

/4

/4

2" HWS

2" HWR

/4

H W

R

3/4"

3/4"

/4

H W

R

UH-4

/4

H

W R

/4

H

W S

FT-1

3 FT 1.2 GPM

FT-1

3FT 1.2 GPMFT-1

3 FT 1.2 GPM

FT-1

3 FT 1.2 GPM

FT-1

10 FT 1.2 GPM

3/4" HWR

1" HWS

/2

H W

S

/2

H

W R

H W

S

1 1/4" HWS

H W

R

H

W S

2" HWR

2" HWS

8.103 8.103

8.103 8.1038.103 (TYP)

(TYP)

(TYP)

M-301

M-301

M-301

M-301

3/4"

RL UTR

RS UTR

1 1/2" CD

DN TO HD

VRF-E130

8.101

LCO

LCO

LCO

H

T

H

H

T

H

T

8.103

8.103

8.1038.103

8.1038.103

8.103

1"

3/4"

3/4"

1 1/2" CD

DN TO HD

H W

R

/4

H

W S

/4

H

W R

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:1

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

M-131

MECHANICAL FLOOR

PLAN

XGFG132020ANG NO.:

3141300-141489.01

RRW/SMG

SNW

May 4, 2017

BGD

PLAN

NORTH

TRUE

NORTH

1/8" = 1'-0"1

MECHANICAL FLOOR PLAN

KEYED NOTES

7.106 ELECTRIC CEILING MOUNTED CABINET UNIT HEATER (ETR)

8.101 ALL CONDENSATE DRAIN PIPING FROM VRF UNITS SHALL BE 3/4" AND

PITCHED AT 1/8" PER FOOT TO MAIN RUN WITH TOP CONNECTION. ALL MAIN

RUNS SHALL BE 1 1/2" UNLESS SHOWN OTHERWISE AND PITCHED TO HUB

DRAIN AT 1/8" PER FOOT.

8.102 CONNECT NEW PIPING TO EXISTING AT APPROXIMATELY THIS POINT.

8.103 GROUND PIPE AT PENETRATION OF SECURE WALL.

05/04/17 TYPE B3

7. ALL REFRIGERATION PIPING TO BE HARD RIGID COPPER EXCEPT FOR DUCTLESS

SPLIT UNITS WHERE LINESETS MAY BE USED.

6. PITCH ALL CONDENSATE DRAIN PIPING TOWARDS FLOOR OR HUB DRAIN.

5. COORDINATE ALL PIPING WITH HVAC DUCTWORK ROUTING.

4. CONTROL CONTRACTOR IS RESPONSIBLE FOR COORDINATING POWER FOR HIS

EQUIPMENT WITH ELECTRICAL CONTRACTOR AND INSURING ALL COSTS

ASSOCIATED WITH SUCH ARE INCLUDED IN THE PROJECT COST.

3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR EXACT LOCATIONS OF

ELECTRICAL PANELS AND EQUIPMENT. DO NOT RUN PIPING/DUCTWORK OVER

TOP OF OR WITHIN 3'-0" CLEAR HORIZONTALLY IN FRONT OF ALL ELECTRICAL

EQUIPMENT OR PANELS.

2. REFER TO SHEET M-001 FOR LEGENDS, ABBREVIATIONS, AND SYMBOLOGY.

1. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE ATTENTION

OF THE ARCHITECT/ENGINEER FOR FINAL DECISIONS.

GENERAL MECHANICAL PIPING NOTES:

G H JG H JG H J

SCHEDULING

HALLWAY

MEN'S

TOILET/

LOCKER

ROOM

VRF-E11810x19 SA

8x10 TA

RL /RS

3/4" CD

12x16 EA

20x14 EA1 1/2" CD

10x8 SA 12x6 RA

12x10 OA

1 1/4" HWR

SA

CD-1CD-1CD-1

3/4" HWR

1/8" / 1'-0"

CDEF

GH

CLASSROOM

INTEL

VAULT

FT-1FT-1

FT-1

FT-1

FT-1

/4

H

W S

3/4" HWR

H W

R

1" HWR

1" HWS

3/4" HWR

3/4" HWR

3/4" HWR

3/4" HWR3/4" HWR

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:1

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

M-301

MECHANICAL

SECTIONS

XGFG132020ANG NO.:

3141300-141489.01

RRW/SMG

SNW

May 4, 2017

BGD

05/04/17 TYPE B3

1/2" = 1'-0"1

ENLARGED SECTION - HALLWAY 131 - LOOKING NORTH

1/2" = 1'-0"2

ENLARGED SECTION - CLASSROOM 110 - LOOKING SOUTH

F.E.

R S TS T

1111 11

12 12

13 13

R

R

S

S

T

T

M-401

M-401

HWB-3 HWB-2 HWB-1

ET-1

AS-1

P-1P-2P-3

2 1/2" HWS

HWS

HWR

NATURAL GAS

METER

(ETR)

UH-1

MECH

3" EXHAUST

(TYP)

3" INLET (TYP)

1 1/2" G

1" G UTR

P-4

P-5

1" G

/4

G

COMBINATION

CHEMICAL

POT

FEEDER/SIDESTREAM

WATER

FILTER

1 1/2" G

/2

G

1155 MBH

CONNECTED

LOAD AT 2 PSIG

/4

/4

/4

1" G

1" CD

/4

C

D

/2

H W

S

/2

H W

R

1 1/2" HWS

(TYP)

1 1/2" HWR

(TYP)

TCP

DDC

PANEL

M-401

M-401

3/4" HWS

3/4" HWR

8.1048.104

1" HWS

1" HWR

/4

H

W S

/4

H

W R

CRAC-3

3/4" G DN TO

WATER HEATER

1 1/2" CD DN TO HD

3/4" HWS

3/4" HWR

RL UTR

RS UTR

R S T

/2

H W

S

/2

H W

S

/2

H W

S

P-1P-2P-3

HWB-1HWB-2HWB-3

ET-1

AS-1

P-5

P-4

/2

H W

S

IN

L

E T

E X

H A

U S

T

IN

L

E T

E X

H A

U S

T

IN

L

E T

E X

H A

U S

T

/2

H W

R

/2

H W

R

/2

H W

R

2 1/2" HWR

UH-1

/4

G

/4

G

/4

G

/2

G

TCP

2 1/2" HWS

2 1/2" HWR

M-401

MECH

8.1048.104

CRAC-3

ACCU-3

RL

RS

131211

M-401

COMBINATION

CHEMICAL

POT

FEEDER/SIDESTREAM

WATER

FILTER

P-5

P-4

ET-1

/2

H W

S

/2

H W

S

2 1/2" HWS

MECH

8.104

G

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:2

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

M-401

MECHANICAL ROOM

ENLARGED PLAN

AND SECTIONS

XGFG132020ANG NO.:

3141300-141489.01

RRW/SMG

SNW

May 4, 2017

BGD

PLAN

NORTH

TRUE

NORTH

1/2" = 1'-0"1

ENLARGED MECHANICAL ROOM PLAN

KEYED NOTES

8.104 COORDINATE WITH GENERAL CONTRACTOR, THE EXACT SIZE AND

LOCATION OF HOUSEKEEPING PADS PER FINAL EQUIPMENT SELECTIONS.

05/04/17 TYPE B3

1/2" = 1'-0"2

ENLARGED MECHANICALROOM SECTION - LOOKING NORTH

1/2" = 1'-0"3

ENLARGED MECHANICALROOM SECTION - LOOKING WEST

CAULK ALL AROUND

DUCT WORK

INSULATION

JACKET

BANDING

FULL LENGTH

PIANO HINGE

FRAME - SAME

MATERIAL AS DUCT

GASKET ALL AROUND

PERIMETER

1" MIN. HIGH-DENSITY

FIBERGLASS INSUL.

DOVETAILS

BANDING

SASH CAM AND LATCH

DOOR - SAME MATERIAL

AS DUCT

3/8"3"

MAX

3/8"3"

MAX

RECTANGULAR DUCT

GASKET ALL AROUND

PERIMETER

SASH CAM AND LATCH

RIVET

ACCESS DOOR OF SAME

MATERIAL AS DUCT

FULL LENGTH PIANO HINGE

WALL

PROVIDE ANGLES AT

TOP AND SIDES

DAMPER WHERE SPECIFIED

SEE DRAWINGS FOR DUCT

SIZE, SEE SPECIFICATION

FOR INSUL. REQUIREMENTS

ACCESS DOOR

(MIN 10"x10")

BIRD SCREEN TO

BE REMOVABLE OR HINGED

AT TOP

PROVIDE INSULATED METAL

PANEL OR UNUSED PROTION

OF LOUVER. CAULK EDGE

FOR AIR TIGHTNESS.

WATERPROOF

CAULKING

ALL AROUND

LOUVER AS

SCHEDULED

CONNECTION

TYP FOR TOP

AND SIDES

KEYED NOTES:

USE PVC COATED METALIC DUCT FOR BOTTOM OF OUTSIDE

AIR INTAKE DUCT FROM LOUVER TO THIS POINT.

DEPRESSED TO AVOID

AN OBSTRUCTION

SMOOTH RADIUS ELLS

TO AVOID AN OBSTRUCTION

H1

W1

L

15°

W2

H2

H1 X W1 = H2 X W2

R=1 1/2 W

PERMISSIBLE ELBOWS

AIR FLOW

PERMISSIBLE TRANSITIONS

AIR FLOW

R

AIR FLOW

R

R=1 1/2 W

R

AIR FLOW

R

5/2

5 6"

R 0' - 0 21 5/2 5

6"

R 0' - 0 21 5/2 5

6"

W

W

W

R=1 1/2 W

45° 45°

DUCT INSULATION

24 GAUGE SHEET METAL SLEEVE,

EXTEND 1 1/2" BEYOND EACH

SIDE

SEAL SLEEVE TO WALL OPENING

WITH FIRE RESISTANT SEALANT

TAPE (2" MIN. WIDTH)

DUCTWORK

SAME SIZE AS GRILLE

7" MIN.

HEIGHT

RETURN AIRFLOW

(TYP. OF 2 ENDS)

LINED SHEET

METAL SOUND

BAFFLE

RETURN AIR GRILLE

LOCATE DAMPER AS FAR

FROM GRILLE AS POSSIBLE

SEAL DUCT CONNECTION

AIR TIGHT (CONNECTION MAY

BE ON TOP OF PLENUM)

SHEET METAL PLENUM.

PAINT INTERIOR OF METAL

PLENUM FLAT BLACK

RETURN/EXHAUST

GRILLE

CEILING

LINEAR SUPPLY GRILLE

VOLUME DAMPER

GRILLE NECK

SUPPLY BRANCH

45º BRANCH DUCT

TAKE-OFF

SUPPLY DUCTWORK

DUCT INSULATION

OPEN ENDED DUCT

SEE DRAWINGS FOR

SIZE AND SHAPE

ANGLE IRON REINFORCING

WELD OR BOLT TO DUCT

PROVIDE AS MANY BOLTS

AND NUTS AS NECESSARY

TO INSURE A SNUG FIT

BETWEEN SCREEN AND

DUCTWORK (TYP)

METAL SCREEN FRAME

INSECT OR BIRD SCREEN

AS SPECIFIED

NOTES:

1 MATERIALS OF CONSTRUCTION SHALL BE SIMILAR TO OPEN

ENDED DUCT (IE STAINLESS STEEL COMPONENTS FOR

STAINLESS STEEL DUCT).

BACKDRAFT DAMPER

- WHERE SCHEDULED

OR SPECIFIED

CENTRIFUGAL ROOF

EXHAUST FAN

BIRDSCREEN WITHIN UNIT

PREFABRICATED ROOF CURB

FINISHED ROOF

ROOF OPENING

EXHAUST DUCT

SEE CURB CAP

FASTENING DETAIL

M-501

NAIL

STAINLESS STEEL

TRUSS HEAD SCREW

(#10 x 1 1/2" MIN.)

CURB

90° FLANGE OUT ON

ALL SIDES COMPLETE

WITH FILLED CORNERS

1-1/2"x3/8" CLOSED

CELL NEOPRENE SELF

ADHESIVE GASKET

ALL AROUND

1/2 X

1/2 X

ACCOUSTICCALLY

LINED SHEET METAL

DUCT - SIZE

AS SHOWN ON PLANS

INTERIOR WALL

X

X

2X

2X

1/2 X

1/2 X

ACCOUSTICCALLY

LINED SHEET METAL

DUCT - SIZE

AS SHOWN ON PLANS

INTERIOR WALL

X

X

2X

2X

SECURED AREA NON-SECURED

AREA

AFC

1/2 X

1/2 X

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:2

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

M-501

MECHANICAL

DETAILS

XGFG132020ANG NO.:

3141300-141489.01

RRW

SNW

May 4, 2017

BGD

NO SCALE1

HINGED ACCESS DOOR

OR INSULATED RECTANGULAR DUCT

NO SCALE2

HINGED ACCESS DOOR

FOR UNINSULATED RECTANGULAR DUCT

NO SCALE4

DUCT CONNECTION TO LOUVER

NO SCALE5

TYPICAL DUCT OFFSET

NO SCALE6

TYPICAL DUCT TRANSITIONS

NO SCALE7

DUCT PENETRATION

THRU INTERIOR WALL

NO SCALE8

PLENUM RETURN GRILLE DUCT CAP

NO SCALE9

RETURN/EXHAUST

GRILLE DUCT CONNECTION

NO SCALE3

RIGID DUCT TO LINEAR WALL GRILLE

NO SCALE12

OPEN ENDED DUCT SCREEN TERMINATION

NO SCALE10

CENTRIFUGAL ROOF EXHAUST FAN

NO SCALE11

CURB CAP FASTENING

05/04/17 TYPE B3

NO SCALE13

NON-SCIF TRANSFER DUCT DETAIL

NO SCALE14

SCIF TRANSFER DUCT DETAIL

A

A

ACCESS

HEAT WHEEL PRE-FILTER 2

HEAT WHEEL3

COOLING COIL5

HOT GAS REHEAT COIL6

GAS FIRED HEAT EXCHANGER

FINAL FILTER

OA

EASA

AIR FLOW

A

A A

A

SUPPLY FAN

HEAT WHEEL EXHAUST AIR FILTER

EXHAUST FAN

3 2

10 10

ELECTRIC PREHEAT

FLEXIBLE DUCT

COLLAR

METAL CLAMP

VOLUME DAMPER

45º BRANCH DUCT TAKE-OFF

SUPPLY DUCTWORK

DUCT INSULATION

/1

MAX. SAG = 1/2" PER

FOOT OF LENGTH

4 19/32"

METAL CLAMP

METAL DUCT ELBOW,

LONG RADIUS, DIE STAMPED

SAME SIZE AS DIFFUSER

INLET CONNECTION

DIFFUSER

CEILING

MAX. LENGTH NOT TO EXCEED 5'-0"

EXTEND AND SPOT WELD

TO STRUCTURE ABOVE (TYP)

SECURE WALL

COMPRESSED 1" WIDE x 1/4"

THICK NEOPRENE GASKET

ALL AROUND BETWEEN

DUCT FLANGE AND WALL

SPACE BARS AT EQUAL SPACES NOTE TO

EXCEED 6" O.C.

FULLY WELD TO FRAME AND EACH OTHER

1/2" Ø SOLID STEEL

SECURITY BARS IN BOTH DIRECTIONS(TYP)

SPOT WELD (TYP)

FLANGE MOUNTED DUCT TO

WALL OPENING WITH

FASTENERS AT 8" O.C. ALL AROUND

ACCESS DOOR

NOTE:

ALL GYPSUM BOARD JOINTS TO

BE PERMANENTLY SEALED AND

PROFESSIONALLY FINISHED IN

ACCORDANCE WITH ACOUSTICAL

GYPSUM WALL BOARD

ASSEMBLIES

SECURED AREA

NON-SECURED

AREA

AFC

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

/4

/2

:4

:2

A M

C R e vi t L o c a l\

-1

.0

-M

-C e n tr a l-rr w .r v t

W

IS

C O

N S

IN

A

IR

N

A T

IO

N

A L G

U A

R D

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

A D

A L B

M-502

MECHANICAL

DETAILS

XGFG132020ANG NO.:

3141300-141489.01

RRW

SNW

May 4, 2017

BGD

05/04/17 TYPE B3

NO SCALE1

AIR HANDLING UNIT COMPONENT VIEW

NO SCALE2

FLEXIBLE DUCT TO CEILING DIFFUSER

NO SCALE3

SECURITY BARS AT DUCT PENETRATION

ROUTE REGULATOR

VENT TO BUILDING

EXTERIOR. TERMINATE

WITH WEATHERPROOF

VENT CAP

12" APPLIANCE

FLEXIBLE CONNECTOR

WITH THREADED

ENDS

APPLIANCE REGULATOR,

IF NOT PART OF

EQUIPMENT

GAS SUPPLY

HEADER

SIZE AS INDICATED

ON DRAWINGS

SHUTOFF VALVE

(TYP)

UNION

SAME SIZE AS

EQUIPMENT

CONNECTION

PLUG OR CAP

SEDIMENT TRAP

PIPE ANCHOR

EQUIPMENT

6"

3'-0"

MAX.

INTERIOR WALL

WALL SLEEVE, OF

SPECIFIED MATERIAL

ESCUTCHEON

WHERE SPECIFIED

PIPE INSULATION

AND JACKETING

WHERE CALLED FOR

TIGHTLY CAULK WITH

SILICONE SEALANT

FOR MIN. 2" EACH END

PIPE - MUST BE

FREE OF STRAIN

TIGHTLY PACKED

WITH FOAM - IN

PLACE INSULATION

1/2" TO 1"

CLEARANCE

ALL SIDES

EXTERIOR WALL

WALL SLEEVE, OF

SPECIFIED MATERIAL

ESCUTCHEON

- WHERE SPECIFIED

PIPE INSULATION

AND JACKETING

WHERE CALLED FOR

TIGHTLY CAULK WITH

SILICONE SEALANT

FOR MIN. 2" EACH END

PIPE - MUST BE

FREE OF STRAIN

TIGHTLY PACKED

WITH FOAMED - IN

PLACE INSULATION

WATERPROOF MASTIC

360˚ AROUND SLEEVE

COLOR TO MATCH WALL

1/2" TO 1"

CLEARANCE

ALL SIDES

UNION

REDUCER

FIN TUBE CONVECTOR

HWS HWR

BALANCING VALVE

AUTOMATIC

CONTROL VALVE

SHUTOFF VALVE

M

AQUASTAT

ROOM

T-STAT

CONTROL DIAGRAM

120V/1ph

CONNECT

TO MAINS

HWS

HWR

AIR FLOW

SHUTOFF VALVE

BALANCING VALVE

STRAINER

CAPPED

DRAIN VALVE

ACV

UNION (TYP)

STRAP-ON

AQUASTAT

UNIT

HEATER

HANGER RODS

TO

STRUCTURE

SEE DWGS

FOR SIZE

HEATING

COIL

REDUCE (TYP)

AS REQUIRED

UNION (TYP)

FLEXIBLE PIPE

CONNECTION

GAGE CONNECTION

(TYP)

3-WAY MIXING

AUTOMATIC CONTROL

VALVE (ACV)

MANUAL AIR VENT

BALANCING VALVE

(TYP)

WATER RETURN

SIZE AS INDICATED

ON PLANS

THERMOMETER

BYPASS LINE

SAME SIZE AS ACV

SHUTOFF VALVE

WATER SUPPLY

SIZE AS INDICATED

ON PLANS

STRAINER WITH BLOW

OFF VALVE AND NIPPLE

3/4" DRAIN VALVE

N.O.

MAKE-UP VALVES

COLD

WATER

FILL

AIR SEPERATOR

REDUCER

(WHERE REQ'D)

TO

SYSTEM

PUMPS(S)

SEE PLANS

FOR PIPE SIZE

/1

12"

MIN

AV

AV

AIR CHARGED

PORT

VERTICAL BLADDER

TYPE EXPANSION

TANK

SHUT-OFF

VALVE (TYP)

PRESSURE

GAUGE

AUTOMATIC

AIR VENT

SEE PLANS

FOR PIPE SIZE

FROM PRIMARY

HEATING/COOLING

EQUIPMENT

REDUCER

WHERE REQ'D

HIGH CAPACITY AIR VENT

EQUAL TO BELL & GOSSET

MODEL #107a

HANGER ROD

SIZE AS SPECIFIED

ADJUSTABLE

CLEVIS HANGER

JACKETING

WHERE SPECIFIED

RIGID INSULATION

AS SPECIFIED

PIPE

INSULATION PROTECTION

SHIELD MATERIAL

EXPANSION BOLT

ANCHOR 'D'

BASE PLATE SIZE 'C'

3/4" LEVELING GROUT

FINISHED FLOOR

PIPE SUPPORT

SIZE 'B'

PIPE SIZE 'A'

CENTERLINE OF PIPE

36" MAX.

BASE PLATE

1 1/2"

1 1/2"

'C' 'A'…

This is the start of the file's text. The full file is on GovTribe.