00_General.pdf
PDF 3 MB Posted
- Solicitation number
- W912J2-18-R-1001
About this file
00 General
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T T
P
RED
W H
IT
E
YE
LL
O W
W H
IT
E
YE
LL
O W
W H
IT
E
W H
IT
E
YE
LL
O W
W H
IT
E
W H
IT
E
W H
IT
E
RED
STATE MAP:
STATE OF WISCONSIN
CITY OF MADISON,
DANE COUNTY
VICINITY MAP:
PROJECT LOCATION
TRUAX BASE MAP:
SOUTH RAMP
TAXIW
AY "D"
T A
X
IW
A Y
B
TAXIWAY "F" MILLER ST.
MITCHELL ST.
PIERSTORFF ST.
MAIN GATE/
ENTRY
T A
X
IW
A Y
G
BASE CIVIL
ENGINEERING
OFFICE (B1210)
PROJECT SITE
(B404)
CONSTRUCTION
HAUL ROUTE
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/4
/2
:4
:0
P M
C R e v it L o c a l\
-1
.0
-A -C e n tr a l-
N a te
D e
M a s te r.
rv t
ANG NO.: XGFG132020
ADAL B404
TRUAX FIELD ANGB
MADISON, WI
WISCONSIN AIR NATIONAL GUARD
W
IS
C O
N S
IN
A
IR
N
A T
IO
N
A L G
U A
R D
T R
U A
X F
IE
L D
A N
G B
M A
D
IS
O N
W
I
A D
A L B
G-001
COVER SHEET
XGFG132020ANG NO.:
3141300-141489.01
NJD
SZK
May 4, 2017
THM
FIRE PROTECTION
F-001 FIRE PROTECTION & FIRE ALARM NOTES, SYMBOLS,
ABBREV., SCHEDULES & DETAILS
F-101 FIRE PROTECTION - FIRST FLOOR PLAN
FD201 FIRST FLOOR DEMOLITION PLAN - FIRE ALARM
F-201 FIRST FLOOR PLAN - FIRE ALARM
PLUMBING
P-001 PLUMBING NOTES & SYMBOLS
PD100 UNDERGROUND - DRAIN AND VENT DEMOLITION PLAN
PD101 FIRST FLOOR - DRAIN AND VENT DEMOLITION PLAN
PD131 FIRST FLOOR - SUPPLY PLUMBING DEMOLITION PLAN
P-100 UNDERGROUND DRAIN AND VENT PLUMBING PLAN
P-101 FIRST FLOOR - DRAIN AND VENT PLUMBING PLAN
P-131 FIRST FLOOR - SUPPLY PLUMBING PLAN
P-501 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-901 PLUMBING RISER DIAGRAM
P-931 SUPPLY ISOMETRIC PLUMBING PLAN
MECHANICAL
M-001 MECHANICAL NOTES & SYMBOLS
MD101 HVAC DEMOLITION FLOOR PLAN
MD102 HVAC DEMOLITION ROOF PLAN
MD131 MECHANICAL DEMOLITION FLOOR PLAN
M-101 HVAC FLOOR PLAN
M-102 HVAC ROOF PLAN
M-131 MECHANICAL FLOOR PLAN
M-301 MECHANICAL SECTIONS
M-401 MECHANICAL ROOM ENLARGED PLAN AND SECTIONS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-531 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-603 MECHANICAL SCHEDULES
M-631 MECHANICAL SCHEDULES
M-632 MECHANICAL SCHEDULES
M-701 MECHANICAL SCHEMATICS
M-801 CONTROL SCHEMATICS
M-802 CONTROL SCHEMATICS
ELECTRICAL
E-001 NOTES, SYMBOLS & ABBREVIATIONS
ED101 FIRST FLOOR DEMOLITION PLAN - LIGHTING
ED131 FIRST FLOOR DEMOLITION PLAN - POWER
E-101 FIRST FLOOR PLAN - LIGHTING
E-131 FIRST FLOOR PLAN - POWER
E-501 DETAILS
E-601 SCHEDULES
E-602 SCHEDULES
E-603 SCHEDULES
E-701 ONE-LINE DIAGRAMS
TECHNOLOGY SYSTEMS
T-001 NOTES, SYMBOLS & ABBREVIATIONS
TD101 FIRST FLOOR DEMOLITION PLAN - TECHNOLOGY
T-101 FIRST FLOOR PLAN - COMMUNICATIONS
T-131 FIRST FLOOR PLAN - SECURITY
T-161 FIRST FLOOR PLAN - AUDIO/VISUAL
T-401 ENLARGED PLANS - ROOM 107
T-402 ENLARGED PLANS - ROOM 171
T-501 DETAILS
T-701 ONE-LINE DIAGRAMS
GENERAL
G-001 COVER SHEET
G-011 OPERATIONS PLAN AND TEMPORARY FACILITIES
G-101 CODE ANALYSIS PLAN
G-102 SECURITY ZONE DIAGRAM PLAN
CIVIL
C-021 EXISTING SITE PLAN
C-031 EROSION CONTROL PLAN
C-041 SITE REMOVALS PLAN
C-101 SITE PAVEMENT AND GRADING PLAN
C-141 SITE UTILITIES PLAN
C-501 SITE DETAILS
LANDSCAPE
L-101 SITE LANDSCAPE PLAN
STRUCTURAL
S-001 STRUCTURAL NOTES
S-101 FOUNDATION PLAN
S-111 FLATWORK PLAN
S-151 LOW ROOF FRAMING PLAN
S-152 INTERMEDIATE ROOF FRAMING PLAN
S-501 FOUNDATION DETAILS
S-511 FLATWORK DETAILS
S-521 STRUCTURAL WALL DETAILS
S-541 FRAMING DETAILS
S-551 FRAMING DETAILS
ARCHITECTURAL
A-001 NOTES & SYMBOLS
AD101 DEMOLITION PLANS
A-101 FIRST FLOOR PLAN
A-102 ROOF PLAN
A-141 PARTITION TYPES
A-201 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-311 WALL SECTIONS
A-401 ENLARGED INTERIOR PLANS
A-402 ENLARGED INTERIOR PLANS & ELEVATIONS
A-403 ENLARGED INTERIOR PLANS & ELEVATIONS
A-404 CASEWORK DETAILS
A-501 EXTERIOR PLAN DETAILS
A-601 DOOR & HARDWARE SCHEDULE
A-602 WINDOW TYPE ELEVATIONS
A-621 DOOR & WINDOW DETAILS
A-701 FINISH PLANS
A-702 FURNITURE PLAN - FOR REFERENCE ONLY
A-721 FIRST FLOOR CEILING PLAN
A-801 SIGNAGE
SHEET INDEX
05/04/17 TYPE B3
0.108
B406
B404
B410
B402
OPERATIONS
0.102
CONSTRUCTION
PERIMETER
FENCE
DO NOT CROSS RED LINE
TEMP. USE
TEMP.
USE
ECP
x x x x
ROOM 126
EXISTING
TRANSFORMER
EXISTING
TRANSFORMER
B400
B401
B409
T4
T3
T2
B503
B307
B305
T1
0.109
0.109
0.109
0.109
0.109
0.109
0.107
0.101
0.101
0.101
0.101
0.103
0.103
0.103
0.104
0.105
0.104
0.105
0.104
0.105
0.104
0.105
0.104
0.105
0.101
0.104
0.105
0.106
HOSE
BIB
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents. In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited.
Mead and Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
X
T
E C
H C
A D
G
B D
W G
P
M
3141300-141489.01
May 4, 2017
XGFG132020
ANGB NO.:
05/04/17 TYPE B3
T R
U A
X
F
I E
L D
A
N G
B
M A
D I S
O N
W
I
W I S
C O
N S
I
I R
T
I O
N A
L
G
U A
R D
A D
L
B
00 30 60
G-011
OPERATIONS PLAN
AND TEMPORARY
FACILITIES
JJB
NJD
JJB
RESTRICTED AREAS/SAFTEY AREAS:
1. RUNWAYS, TAXIWAYS, AND APRON: CONSTRUCTION ACTIVITY ADJACENT TO THE RUNWAYS,
TAXIWAYS, AND APRONS WHICH WILL BE IN USE SHALL BE COORDINATED WITH AIRPORT
OPERATIONS THROUGH THE COR. CONSTRUCTION ACTIVITY WILL BE AUTHORIZED AFTER
NOTAMS (NOTICES TO AIRMEN) HAVE BEEN ISSUED BY THE AIRPORT (DCRA); AND AFTER IT HAS
BEEN DETERMINED THAT THE HEIGHT OF EQUIPMENT AND MATERIALS IS BEYOND THE REACH OF
THE AIRCRAFT OR SAFELY BELOW ANY PART OF THE AIRCRAFT USING THE OPERATIONS AREAS
WHICH MIGHT OVERHANG THESE AREAS. INFORMATION FOR RUNWAY APPROACHES AND OTHER
AREAS WILL BE SUPPLIED BY THE C.O.R. IF IT IS REQUIRED.
2. EXCEPT AS PROVIDED ON THE CONTRACT PLANS OR IN CONTRACT SPECIAL PROVISIONS OR AS
MAY BE AUTHORIZED BY THE C.O.R. IN WRITING, THE CONTRACTOR SHALL PERFORM
CONSTRUCTION ACTIVITIES WITHIN 80 FEET OF THE EDGE OF AN ACTIVE TAXIWAY OR APRON, WITHIN 250 FEET OF AN ACTIVE RUNWAY CENTERLINE, OR WITHIN 1000 FEET OF A RUNWAY END.
WHEN SO AUTHORIZED TO PERFORM CONSTRUCTION ACTIVITIES WITHIN SUCH AREAS, THE
CONTRACTOR SHALL FIRST IMPLEMENT APPROPRIATE MARKING AND LIGHTING PROVISIONS.
3. EXCAVATION AND OPEN TRENCHES LOCATED WITHIN 250 FEET FROM THE CENTERLINE OF AN
ACTIVE RUNWAY SHALL BE ADEQUATELY SIGNED, MARKED AND LIGHTED. EXCAVATIONS AND
OPEN TRENCHES LOCATED ADJACENT TO TAXIWAY AND APRON PAVEMENT SHALL BE
ADEQUATELY SIGNED, MARKED AND LIGHTED.
4. DEBRIS SHALL NOT BE DEPOSITED ON ANY PORTION OF AN OPERATIONAL RUNWAY, TAXIWAY, OR
APRON. SHOULD ANY DEBRIS BE DEPOSITED ACCIDENTALLY, IT SHALL BE REMOVED
IMMEDIATELY.
5. OPEN-FLAME WELDING OR TORCH-CUTTING OPERATIONS ARE PROHIBITED UNLESS ADEQUATE
FIRE AND SAFETY PRECAUTIONS ARE PROVIDED AND HAVE BEEN APPROVED BY THE TRUAX FIRE
DEPT. ALL VEHICLES ARE TO BE PARKED AND SERVICED BEHIND THE CONSTRUCTION
RESTRICTION LINE 750 FEET OR MORE FROM AN ACTIVE RUNWAY CENTERLINE OR 200 FEET FROM
AN ACTIVE TAXIWAY CENTERLINE.
MARKING AND LIGHTING:
1. EXCAVATION/STOCKPILES-EXCAVATION ADJACENT TO PAVED SURFACES MUST BE
APPROPRIATELY MARKED BY BARRICADES.
2. CONTRACTOR SHALL BARRICADE OPEN EXCAVATIONS AS REQUIRED BY THE C.O.R.
FUEL SUPPORT:
1. ANY TYPE OF FUELING SUPPORT FACILITY OR DEVICE USED TO REFUEL CONSTRUCTION
EQUIPMENT IS SUBJECT TO WANG FIRE INSPECTION. LOCAL FIRE CODES AND SAFETY
STANDARDS SHALL BE MET PRIOR TO COMMENCEMENT OF WORK.
SWEEPING/CLEAN-UP:
1. THE CONTRACTOR SHALL HAVE SWEEPING OR VACUUMING CAPABILITIES ON-SITE AT ALL TIMES
IN ORDER TO REMOVE DEBRIS AS IT OCCURS. UPON COMPLETION, THE CONTRACTOR IS
RESPONSIBLE FOR INSURING THAT THE AREA OF CONCERN IS RETURNED TO ITS ORIGINAL
CONDITION.
HAUL ROUTES:
1. HAUL ROUTES AND ACCESS TO THE CONSTRUCTION SITES WILL BE DISCUSSED AT THE PRE-BID
CONFERENCE AND ARE DEPICTED ON G-001.
2. THE CONTRACTOR SHALL CONDUCT HIS OPERATIONS ON THE BASE IN A MANNER THAT WILL
MINIMIZE INTERFERENCE WITH THE NORMAL OPERATIONS OF AIRPORT FACILITIES THAT ARE TO
REMAIN OPEN TO AIR TRAFFIC, AND THE CONTRACTOR SHALL IMPLEMENT ALL SPECIFIED AND
OTHER APPROPRIATE MEASURES TO ENSURE THE SAFETY OF ALL USERS OF THE AIRPORT.
3. THE CONTRACTOR SHALL ALSO ABIDE BY ALL WANG REQUIREMENTS CONTAINED WITHIN THE
SPECIFICATIONS.
4. CONTRACTOR SHALL NOT USE RADIO EQUIPMENT OR CELL PHONES WITHIN 400 FEET OF
AIRCRAFT.
ENFORCEMENT:
1. VIOLATION OF THESE RULES AND REGULATIONS, DEPENDING UPON SEVERITY OF THE VIOLATION, MAY RESULT IN ONE OR MORE OF THE FOLLOWING:
1.1. A VERBAL AND/OR WRITTEN WARNING.
1.2. REVOCATION OF AOA BADGE AND/OR VEHICLE ACCESS PERMIT.
1.3. THE CONTRACT WORK BEING STOPPED UNTIL CORRECTIVE MEASURES ARE TAKEN TO
PRECLUDE A RECURRENCE OF THE VIOLATION.
2. CONTRACTOR SHALL ALSO ABIDE BY ALL WANG REQUIREMENTS CONTAINED WITHIN THE
SPECIFICATION.
KEYED NOTES:
X.XXX
0.101 TEMPORARY FACILITY TRAILER 12'-0" x 56'-0" (TYP. OF 5) - REF CONTRACTING
OFFICER REPRESENTATIVE REGARDING FINAL LAYOUT.
0.102 TEMPORARY FACILITY DOUBLE WIDE TRAILER 24'-0" x 60'-0" - REF
CONTRACTING OFFICER REPRESENTATIVE REGARDING FINAL LAYOUT.
0.103 PROVIDE SINGLE UNISEX TOILET IN TRAILER. CONTRACTOR TO PLUMB WATER
FROM EXISTING HOSE BIB ON B402. PROTECT WATER LINE FROM PERIODIC
TRAFFIC AND WINTER CONDITIONS.
0.104 PROVIDE TEMPORARY POWER TO TRAILERS FOR DURATION OF
CONSTRUCTION. PROVIDE A 100 AMP 120/240V SINGLE PHASE FEEDER TO
EACH TRAILER. CONTRACTOR SHALL FIELD VERIFY AND COORDINATE
SOURCE OF POWER. POWER MAY BE SUPPLIED BY A TEMPORARY UTILITY
SERVICE (WE ENERGIES), OR BY BUILDING ELECTRICAL DISTRIBUTION.
PROVIDE ALL NECESSARY FEEDER BREAKERS, CABLING, AND SUPPORT AS
NECESSARY. REMOVE TEMPORARY POWER AT END OF CONSTRUCTION.
0.105 PROVIDE TEMPORARY NETWORK COMMUNICATIONS TO TRAILERS FOR
DURATION OF CONSTRUCTION. PROVIDE TWO DUPLEX SINGLE MODE LC/UPC
FIBER CABLES AND A 25 PAIR CAT5 CABLE FROM ROOM 126 IN B402, THROUGH
THE ATTIC, EXITING THE WEST SIDE OF THE BUILDING.
0.106 PROVIDE PORTABLE CHAIN LINK FENCING FOR SECURE TRAILER
SURROUNDING THE DOUBLE WIDE TRAILER. SEE SPECIFICATION 015100
FOR FENCE REQUIREMENTS.
0.107 MAINTAIN CLEAR DRIVE AND GATE, TYP.
0.108 MAINTAIN 10'-0" CLEAR, TYP.
0.109 MAINTAIN 6'-0" CLEAR, TYP.
"OPERATIONAL SAFETY ON AIRPORTS DURING CONSTRUCTION":
CONFORMS TO AC150/5370-2E
1. CONTRACTOR SHALL REMOVE FENCE AND PATCH PAVEMENT AND LANDSCAPING
DAMAGED FROM TRAILERS AND FENCING DURING PROJECT.
GENERAL NOTES:
AutoCAD SHX Text
MITCHELL ST
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
F.E.
F.E.
F.E.
REF.
D W
R E
F
DW
REF.
CODE PLAN LEGEND:
OCCUPANT LOAD
(OR MAX. CAPACITY)6
XX"
XX"
OCCUPANT LOAD FACTOR
REQ'D WIDTH
PROVIDED WIDTH
EXIT DISCHARGE
1 HR RATED WALL
F.E. FIRE EXTINGUISHER -
WALL MOUNTED
F.E.C. FIRE EXTINGUISHER
- CABINET
AREA EXIT
EXIT PATHWAYS
1 HR RATED
FLOOR SYSTEM
CCA
OSS
COMMANDER
OPERATIONS
GROUP
COMMANDER
FIGHTER
SQUADRON
COMMANDER
VEST
HALLWAY
DIRECTOR OF
OPERATIONS
AIRFIELD
MANAGEMENT
AFMT NCOIC
OPERATIONS
CHIEF
STAN EVAL
CONFERENCE
ROOM
AFE NCOIC
MEN'S TOILET/
LOCKER ROOM
AIRCREW
FLIGHT
EQUIPMENT
SOF
SIMULATOR
SUPPORT
OFFICE
SCHEDULING
STORAGE
FLIGHT
COMMANDERS
ARMS
ARMS NCOIC
SECURED
VEST
MX DEBRIEF
COMM/
COMPUTER
STORAGE
WEAPONS
ACMI
CLASSROOM
INTEL VAULT
INTEL
INTEL NCOIC
INTEL OIC
BRIEFING
ROOM 3
BRIEFING
ROOM 1
BRIEFING
ROOM 2
BRIEFING
ROOM 4
LIBRARY
STORAGE
BREAK ROOM
ISSO & SSR
MISSION
PLANNING
OPEN OFFICE
PM/PSM
SECURE
VAULT
VEST
LOBBY
MAIN
BRIEFING
ROOM
KITCHEN/
VENDING
BREAK ROOM
VEST
HALLWAY
STORAGE
AFE
INSPECTION
ROOM
COMM
ELEC
AFE
STORAGE
MECH
ELEC
FIRE ALARM
CORR
JANITOR
WOMEN'S TOILET/
LOCKER ROOM
AFE
SUPERINTENDENT,
FEO
NVG
COPY ROOM
TRAINING
OFFICER
SIMULATOR
HALLWAY
VEST
HALLWAY
VEST
HALLWAY
23' - 6"
.6"
72"
10' - 0"
8' - 6"
31' - 1"
7' - 9"
41' - 2"
20' - 0"
24' - 3"
24' - 7"
33' - 10" 33' - 1"
15' - 9"
11' - 1"
11' - 6"
26' - 11"
11' - 4"
39' - 7"
11' - 6"
10"
36"
9.4"
36"
10"
36"
10"
36"
10"
36"
10"
72"
FEC
FEC
FEC
FEC
FECAED
8"
36"
8"
36"
9.8"
36"
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/4
/2
:4
:0
P M
C R e v it L o c a l\
-1
.0
-A -C e n tr a l-
N a te
D e
M a s te r.
rv t
W
IS
C O
N S
IN
A
IR
N
A T
IO
N
A L G
U A
R D
T R
U A
X F
IE
L D
A N
G B
M A
D
IS
O N
W
I
A D
A L B
G-101
CODE ANALYSIS
PLAN
XGFG132020ANG NO.:
3141300-141489.01
NJD
SZK
May 4, 2017
THM
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"1 CODE ANALYSIS PLAN IBC Lavatories - 1 per first 40 + 1 per 80 - 2 Male, 1 Female
Lavatories (industrial office 1 per 3 Lavs) - 2 Male, 1 Female Drinking Fountains: 1 per 75 persons - 2 required required, one for one.
Urinals - male: Urinals may be substituted for no more than one-third of the water closets
Water Closets - 4 Male, 2 Female
Actural Employees = 72 Male, 20 Female
Minimum Number of Plumbing Fixtures
UFC 3-420-01, Section 402.1.D
Plumbing Fixtures:
Provide and installed in accordance with this section.
IBC Section 906
Fire Extinguishers, General:
Group A (Assembly) Occupancies 250 feet Group B (Business) Occupancies 300 feet
IBC Table 1014.3
Travel Distance to Exits:
Group A (Assembly) Occupancies w/ fixed seating 30 feet with sprinkler Group B (Business) Occupancies 100 feet with sprinkler IBC Table 1014.3
Common Path of Travel:
Group B (Business) Occupancies 50 feet with sprinkler
IBC Table 1018.4
Dead-end Corridor Distance:
Total Occupants: 300
1st Floor 21,083 300
Floor Level Area Occupants Accessory Storage / Mechanical = 1 occupant / 300 gsf - 866 SF /300 = 3 Occupants
Assembly (Fixed Seating): = 112 occupants
Business Occupancy: 1 occupant / 100 gsf - 18540 SF /100 = 186 Occupants
IBC Table 1004
Occupant Load:
300 x .2 = 64 inches width required
Other egress = .2 inches per occupant
IBC Table 1005 Minumum Exterior Door is = 36"
Minumum clear width = 32"
IBC Table 1008.1
Means of Egress:
Not less than 44-inches minimum
Clear width of any corridor or passageway
IBC Table 1018.1
Corridors:
Floor Classification: Class II (Minimum)
IBC Table 804.4.1 Rooms and Enclosed Spaces: Class C (Minimum)
Corridors: Group B, Class C (Minimum) Group A3, B (Minimum)
Exit Enclosures & Passageways: Class B (Minimum)
IBC Table 803.9
Interior Wall and Ceiling Finishes:
X ≥ 30 ft 0 hr
Group B, Type IIB Construction
Exterior Nonbearing Walls and Partitions where "x" is distance from fire separation
IBC Table 602
Fire-Resistance Rating Requirements for Exterior Walls Based on Fire Separation Distance
Roof Construction 0 hr Floor Construction 0 hr Interior 0 hr
Nonbearing walls and Partitions
Exterior 0 hr Nonbearing walls and Partitions
Interior 0 hr
Exterior 0 hr
Bearing Walls
Primary structural frame 0 hr
Group B & A3, Type IIIB Construction
IBC Table 601
Fire-Resistance Rating Requirements for Building Elements (Hours)
Actual Gross Building Area = 21,083 SF
Group A3 / IIB = 9,500 s.f. (Actual A3 area = 1,295)
Group B / IIB = 23,000 s.f.
IBC Table 506.2:
Building Area:
Actual Stories = 1
Group A3 / IIB = 2 Stories
Group B / IIB = 3 Stories
IBC Table 504.4:
Allowable Number of Stories Above Grade Plane
Actual Building Height = 20 feet
Group A3 / IIB = 55 Feet High
Group B / IIB = 55 Feet High
IBC Table 504.3:
Allowable Building Height
Sprinklered: Yes
Type IIB
IBC Table 601
Construction Type:
IBC Section 303.1: Assembly Group A3 (Training) 1hr separation required and provided between B and A3 occupancy
IBC Section 304.1: Business Group B (Offices / Training)
Building Occupancy Classifications:
Madison, Wisconsin
Truax Field ANGB
ANGB-ADAL Squadron Operations, B404 - Wisconsin Air National Guard
Project Name and Location:
FIRE PROTECTION AND LIFE SAFETY CODE ANALYSIS
05/04/17 TYPE B3
SECURITY ZONE DIAGRAM LEGEND:
SECURITY ZONE 1
SECURITY ZONE 2
SECURITY ZONE 3
SECURITY WALLS
• STC-55 RATED
• SECURE ALL
PENETRATIONS
• SURFACE MOUNT
OUTLETS AND CONDUIT
SCIF GENERAL NOTES:
1. THE VAULT AREA IS CONSIDERED A SENSITIVE COMPARTMENTED
INFORMATION FACILITY. ALL NEW CONSTRUCTION AND RENOVATION TO THE
AREA INCLUDING WALL CONSTRUCTION, FIRE PROTECTION/DETECTION,
MECHANICAL/HVAC, ELECTRICAL, AND TECHNOLOGY SYSTEMS MUST
COMPLY WITH THE REQUIREMENTS PROVIDED IN UNIFIED FACILITY CRITERIA
4-010-05 SENSITIVE COMPARTMENTED INFORMATION FACILITY PLANNING,
DESIGN, AND CONSTRUCTION WITH CHANGE 1, 1 OCTOBER 2013, AND
REFERENCED IC TECH SPEC FOR ICD/ICS 705 TECHNICAL SPECIFICATIONS
FOR CONSTRUCTION AND MANAGEMENT OF SENSITIVE COMPARTMENTED
INFORMATION FACILITIES, VERSION 1.2, DATED 23 APRIL 2012.
2. CONSTRUCTION, GENERAL: UFC 4-010-05 REQUIREMENTS HAVE BEEN
INCORPORATED INTO THE DESIGN DRAWINGS AND SPECIFICATIONS.
CHANGES TO THE SCOPE OF WORK PROVIDED IN THE CONTRACT
DOCUMENTS MAY INVALIDATE THE APPROVALS RECEIVED FOR THIS
CONSTRUCTION, AND COULD RESULT IN THE REMOVAL AND
RECONSTRUCTION OF FINISHED WORK. ANY PROPOSED DEVIATIONS FROM
THE CONTRACT DOCUMENTS MUST BE FULLY REVIEWED AND APPROVED BY
THE COR PRIOR TO IMPLEMENTATION.
3. ALL CONSTRUCTION MUST BE DONE IN SUCH A MANNER AS TO PROVIDE
VISUAL EVIDENCE OF UNAUTHORIZED PENETRATION. CONSTRUCTION MUST
BE COMPLETED IN A MANNER TO PROVIDE THE REQUIRED STC RATINGS FOR
SOUND CONTROL AT THE WALLS IDENTIFIED. THROUGH-WALL
PENETRATIONS OF PIPE, CONDUIT, AND DUCTWORK REQUIRE SPECIAL
CONSTRUCTION AND INSPECTION PROVISIONS WHICH HAVE BEEN
INCORPORATED INTO THE CONTRACT DOCUMENTS.
4. THE CONTRACTOR SHALL SUBMIT A LIST OF ALL MATERIALS USED IN THE
CONSTRUCTION OF THE VAULT AREA, INCLUDING DIMENSIONAL EXTENTS OF
THE USE AND LOCATION(S) WHERE USED IN THE VAULT. THIS LIST SHALL BE
KEPT UP TO DATE DURING THE COURSE OF CONSTRUCTION AND SUBMITTED
TO THE COR AS PART OF THE CLOSE-OUT REQUIREMENTS AT THE END OF
CONSTRUCTION.
5. PHOTOGRAPHY REQUIREMENTS: THE CONTRACTOR IS NOT ALLOWED TO
HAVE PHOTOGRAPHIC OR RECORDING DEVICES IN THE VAULT AREA. 115 FW
CCZ PERSONNEL WILL BE TAKING PICTURES OF ON-GOING CONSTRUCTION
IN ORDER TO DOCUMENT THAT ALL SECURITY MEASURES ARE BEING MET.
THE COR SHALL BE NOTIFIED AT LEAST ONE WORKING DAY PRIOR TO KEY
CONSTRUCTION MILESTONES. KEY CONSTRUCTION MILESTONES INCLUDE
BUT ARE NOT LIMITED TO: WALL CONSTRUCTION, INCLUDING EACH OF
MULTIPLE LAYERS OF GYPSUM BOARD, FINISHING OF PENETRATIONS,
NON-CONDUCTIVE BREAKS OF PENETRATIONS, AND SOUND BATT
INSULATION INSTALLATIONS.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
/4
/2
:4
:0
P M
C R e v it L o c a l\
-1
.0
-A -C e n tr a l-
N a te
D e
M a s te r.
rv t
W
IS
C O
N S
IN
A
IR
N
A T
IO
N
A L G
U A
R D
T R
U A
X F
IE
L D
A N
G B
M A
D
IS
O N
W
I
A D
A L B
G-102
SECURITY ZONE
DIAGRAM PLAN
XGFG132020ANG NO.:
3141300-141489.01
NJD
SZK
May 4, 2017
THM
05/04/17 TYPE B3
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"1
SECURITY ZONE DIAGRAM
| G-001 |
| G-011 |
| G-101 |
| G-102 |
File details come from the government source that posted it.